HomeMy WebLinkAboutEnergy Code�. a I Ir-0 � Of 2 FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Jefferson Residence Ave Q Builder Name: Street: 4501 Avenue Q Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , 34947 Permit Number: Owner: Jefferson Residence Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type41680.0 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.0 1584.00 ft2 b. Concrete Block - Int Insul, Exterior R=4.1 96.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 5 d. N/A R= ft2 11. Ceiling Types (2196.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2196.00 ft 6. Conditioned floor area above grade (ftz) 2196 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(76.0 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Laundry R ft2 6 85 a. U-Factor: 5g1, U=1.05 76.00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 45,0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 3.000 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a. Electric Strip Heat 34.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) N/A ft2 16. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9: Floor Types. (2196.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2196.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits CF, Pstat Total Proposed Modified Loads: 59.82 Glass/Floor Area: 0.035 PASS Total Baseline Loads: 61.71 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this _06 Code. calculation indicates compliance with the Florida Energy Code. PREP BY: Before construction is completed u� DATE: this building will be inspected for compliance with Section 553.908 hereby certify that this building, as designed, is in compliance Florida Statutes. � with the Florida Energy Code. GQD VwE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed In accordance with 14403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402A.1.2). FILE COPY 1/25/2021 12:18 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 6 I:nRnn Rani;_gron INPIIT SUMMARY CHECKLIST REPORT PROJECT Title: Jefferson Residence Ave Q Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 2196 Lot # Owner Name: Jefferson Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No Plat000k: Builder Name: Rotate Angle: 0 Street: 4501 Avenue Q Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34947 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp J Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2196 17568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Laundry 110 880 No 0 1 Yes Yes Yes 2 Kitchen 224 1792 Yes 2 1 Yes Yes Yes 3 Master Bedroom 210 1680 No 2 1 1 Yes Yes Yes 4 Master Bath 159 1272 No 1 1 Yes Yes Yes 5 Foyer 48 384 No 0 1 Yes Yes Yes 6 Dining 72 576 No 4 1 No Yes Yes 7 Living Room 208 1664 No 2 1 Yes Yes Yes 8 Bedroom 2 192 1536 No 2 1 1 Yes Yes Yes 9 Bath 2 40 320 No 0 1 No Yes Yes 10 WIC 2 20 160 No 0 1 No Yes Yes 11 WIC 3 20 160 No 0 1 Yes Yes Yes 12 Bedroom 3 192 1536 No 2 1 1 Yes Yes Yes 13 Bath 3 45 360 No 0 1 Yes Yes Yes 14 Bedroom 4 159 1272 No 2 1 1 Yes Yes Yes 15 Bedroom 5 161 1288 No 2 1 1 Yes Yes Yes 16 Hall 60 480 No 0 1 No Yes Yes L17 Family Room 276 2208 No 2 1 Yes Yes Yes 1/25/2021 12:18 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R4nr,-2f120 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Laundry 15 ft 110 ft2 1 0 0 2 Slab -On -Grade Edge Insulatio Kitchen i ft 224 ft' __-_ 1 0 0 3 Slab -On -Grade Edge Insulatio Master Bedroom 14 ft 210 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulatio Master Bath 29 ft 159 ft2 _-_- 1 0 0 5 Slab -On -Grade Edge Insulatio Foyer 6 ft 48 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulatio Dining 1 ft 72 ft2 ____ 1 0 0 7 Slab -On -Grade Edge Insulatio Living Room 11 ft 208 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulatio Bedroom 2 12 ft 192 ft2 ____ 1 0 0 9 Slab -On -Grade Edge Insulatio Bath 2 1 ft 40 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulatio WIC 2 1 ft 20 ft2 1 0 0 11Slab-On-Grade Edge Insulatio WIC 3 5 ft 20 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulatio Bedroom 3 28 ft 192 ft2 1 0 0 13SIab-On-Grade Edge Insulatio Bath 3 5 ft 45 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulatio Bedroom 4 27 ft 159 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulatio Bedroom 5 loft 161 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulatio Hall 1 ft 60 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulatio Family Room 47 ft 276 ft2 ____ 1 0 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2379 ft2 0 ft2 Medium N 0.6 No 0.9 No 0 22.62 ATTIC in) Area RBS IRCC V # Type Ventilation Vent Ratio (1 1 Full attic Vented 150 2196 ft2 N N 1/25/2021 12:18 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Laundry 30 Batt 110 ft' 0.1 Wood 2 Under Attic (Vented) Kitchen 30 Batt 224 ftZ 0.1 Wood 3 Under Attic (Vented) Master Bedroom 30 Batt 210 ftZ 0.1 Wood 4 Under Attic (Vented) Master Bath 30 Batt 159 ftz 0.1 Wood 5 Under Attic (Vented) Foyer 30 Batt 48 ftZ 0.1 Wood 6 Under Attic (Vented) Dining 30 Batt 72 ftZ 0.1 Wood 7 Under Attic (Vented) Living Room 30 Batt 208 ft' 0.1 Wood 8 Under Attic (Vented) Bedroom 2 30 Batt 192 ftZ 0.1 Wood 9 Under Attic (Vented) Bath 2 30 Batt 40 ftZ 0.1 Wood 10 Under Attic (Vented) WIC 2 30 Batt 20 ft' 0.1 Wood 11 Under Attic (Vented) WIC 3 30 Batt 20 ftZ 0.1 Wood 12 Under Attic (Vented) Bedroom 3 30 Batt 192 ftZ 0.1 Wood 13 Under Attic (Vented) Bath 3 30 Batt 45 ftz 0.1 Wood 14 Under Attic (Vented) Bedroom 4 30 Batt 159 ftZ 0.1 Wood 15 Under Attic (Vented) Bedroom 5 30 Batt 161 ftZ 0.1 Wood 16 Under Attic (Vented) Hall 30 Batt 60 ft' 0.1 Wood 17 Under Attic (Vented) Family Room 30 Batt 276 ftZ 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 E Exterior Concrete Block - Int Insul Laundry 4 11 0 8 0 88.0 ft' 0 0 0.5 0 _ 2 S Exterior Concrete Block - Int Insul Laundry 4 4 0 8 0 32.0 ftz 0 0 0.5 0 3 S Exterior Concrete Block - Int Insul Kitchen 4 1 0 8 0 8.0 ftZ 0 0 0.5 0 4 E Exterior Concrete Block - Int InsMaster Bedro 4 14 0 8 0 112.0 ft' 0 0 0.5 0 5 N Exterior Concrete Block - Int InsdlAaster Bath 4 15 0 8 0 120.0 ftz 0 0 0.5 0 6 E Exterior Concrete Block - Int InsWaster Bath 4 11 0 8 0 88.0 ft' 0 0 0.5 0 7 W Exterior Concrete Block - Int InsUMaster Bath 4 3 0 8 0 24.0 ft' 0 0 0.6 0 _ 8 N Exterior Concrete Block - Int Insul Foyer 4 6 0 8 0 48.0 ftZ 0 0 0.5 0 9 N Exterior Concrete Block - Int Insdliving Room 4 11 0 8 0 88.0 ftZ 0 0 0.5 0 10 S Exterior Concrete Block - Int InsuBedroom 2 4 12 0 8 0 96.0 ft' 0 0 0.5 0 11 S Exterior Concrete Block- Int Insul WIC 3 4 5 0 8 0 40.0 ftZ 0 0 0.5 0 12 S Exterior Concrete Block - Int InsuBedroom 3 4 12 0 8 0 96.0 ftZ 0 0 0.5 0 13 W Exterior Concrete Block- Int InsuBedroom 3 4 16 0 8 0 128.0 ft' 0 0 0.5 0 14 W Exterior Concrete Block - Int Insul Bath 3 4 5 0 8 0 40.0 ftZ 0 0 0.5 0 15 N Exterior Concrete Block - Int InsuBedroom 4 4 15 0 8 0 120.0 ftZ 0 0 0.6 0 16 W Extcrior Concrctc Block - Int InsuBcdroom 4 4 12 0 8 0 96.0 ft' 0 0 0.5 0 17 N Exterior Concrete Block - Int InsuBedroom 5 4 10 0 8 0 80.0 ftZ 0 0 0.5 0 18 E Exterior Concrete Block - Int InsBlamily Room 4 12 0 8 0 96.0 ftZ 0 0 0.5 0 19 S Exterior Concrete Block - Int InsUbmily Room 4 23 0 8 0 184.0 ft' 0 0 0.5 0 _20 W Exterior Concrete Block - Int InsElamily Room 4.1 12 0 8 0 96.0 ft' 0 0 0.5 0 1/25/2021 12:18 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R4fK-2n2n INPUT SUMMARY CHECKLIST REPORT DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 2 3 E N W Wood Wood Wood Laundry None .39 3 Foyer None .39 3 Family Room None .39 3 6 10 6 10 6 10 20.5 ft2 20.4 ft' 20.5 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 E 4 Metal N 9 Metal S 10 Metal S 12 Metal N 15 Metal N 17 Metal W 20 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes 1.05 0.25 Y 9.5 ft2 2 ft 0 in 1 ft 4 in 1.05 0.25 Y 19.0 ft2 6 ft 0 in 1 ft 4 in 1.05 0.25 Y 9.5 ft2 2 ft 0 in 1 ft 4 in 1.05 0.25 Y 9.5 ft2 2 ft 0 in 1 ft 4 in 1.05 0.25 Y 9.5 ft2 2 ft 0 in 1 ft 4 in 1.05 0.25 Y 9.5 ft2 2 ft 0 in 1 ft 4 in 1.05 0.25 Y 9.5 ft2 2 ft 0 in 1 ft4 in None None None None None None None None None None None None None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000305 1756.8 96.38 180.95 .1083 6 HEATING SYSTEM # 1 System Type Electric Strip Heat/ Subtype None Speed Efficiency Capacity COPA 34 kBtu/hr Block 1 Ducts sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 45 kBtu/hr 1350 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Laundry 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 1/25/2021 12:18 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FnRM R4nS_?ngn INPUT SUMMARY CHECKLIST REPORT DUCTS — Supply --- — Return -- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 85 ft2 Attic 25 ft2 Default Leakage Laundry (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling� ]] Jan [[ ]] Feb Heatin(X] Jan [X] Feb [[ ]] Mar [X] Mar Apr E Apr IS [X] Jun ] Jun Jul Jul [X] AugX] I ] Au9 Se [ ] Sep [ ] Oct [ j [ ] Oct [X] Nov Nov Dec Dec Ventin [[ �� Jan [[ ]] Feb [[XX]] Mar [X] A r ]Jun E Jul [ j Au [ ] Se [X] Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 Ibs/sq.ft. ft2 ft 0.3 Living Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(B Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 3 Default(8 Ibs/sq ff. ft2 ft 0.3 Bedroom 3 Default(B Ibs/sq.ft. ft2 ft 0.3 Bath 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 5 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall Default(8 Ibs/s .ft. ft2 ft 0.3 Family Room 1/25/2021 12:18 PM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Jefferson Residence Ave Q Builder Name: Street: 4501 Avenue Q Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL, 34947 Permit Number: Y U Owner: Jefferson Residence Jurisdiction: St. Lucie County w Design Location: FL, Fort Pierce v COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier, not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floorframing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spat s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface, thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and woring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire so inkler cover plates and walls or railings, a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1/25/2021 12:19 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY FERF-OR IANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2 7. Windows*` Description a. U-Factor: Sgl, U=1.05 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 4501 Avenue Q, Fort Pierce, FL, 34947 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.0 1584.00 ft2 b. Concrete Block - Int Insul, Exterior R=4.1 96.00 ft2 1 c. N/A R= ft2 5 d. NIA R= ft2 11. Ceiling Type and insulation level Insulation Area No a. Under Attic (Vented) R=30.0 2196.00 ft2 2196 b. N/A R= ft2 Area c. N/A R= ft2 12. Ducts, location & insulation level R ft2 76.D0 ft2 a. Sup: Attic, Ret: Attic, AH: Laundry 6 85 ft2 13. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 45.0 SEER:16.00 ft2 3.000 ft. 0.250 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2196.00 ft2 b. NIA R= ft2 c. N/A R= ft2 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: kBtu/hr Efficiency 34.0 COP:1.00 Cap: 50 gallons EF: 0.95 CF, Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/25/2021 12:18 PM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 -- wrightsoft Project Summary Date: Enure House By: Quick Calcs, Inc. 317 St Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: qulckcalcs@aol.com Project• • For: Jefferson Residence 4501 Avenue Q, Fort Pierce, FL 34947 Notes: Design Inf• • Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 °F Outside db 90 °F Inside db 70 °F Inside db 75 °F Design TD 28 'F Design TD 15 °F Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20240 Btuh Structure 21717 Btuh Ducts 7666 Btuh Ducts 9506 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27906 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Btuh Infiltration Equipment sensible load 29661 Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 6957 Btuh Ducts 3082 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ftz) 2196 2199 Equipment latent load 10039 Btuh Volume (ft') 17568 17568 Air changes/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 39701 Btuh Equiv. AVF (cfm) 94 47 Req. total capacity at 0.70 SHR 3.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make (woodman Mfa. Trade Trade GOODMAN Model Cond GSX16S481A AHRI ref Coil ASPT49D14A AHRI ref 201785242 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.7 kW Sensible cooling 31500 Btuh Heating output 26441 Btuh Latent cooling 13500 Btuh Temperature rise 16 °F Total cooling 45000 Btuh Actual air flow 1500 cfm Actual air flow 1500 cfm Air flow factor 0.054 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.76 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. . wrightsa t- 2021-Jan-2512:15:45 .,».-o•....., WghtSulte®Un1versml201919.021RSU08101 Pagel ACCIN ...nts\Wrightsoft HVAC1Johnson Residence Ave Q.rup Calc = MJB Front Door faces: N r- wrightsoft• Right-JO Worksheet Entire House Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com Job: Date: By. 1 Room name Entire House Laundry 2 Exposed wall 210.0 ft 15.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 10.0 x 11.0 ft 5 Room area 2196.0 fN 110.0 ft T Y Construction number U-value (Btuhlft'= F Or I HTM (Btuhlit'j I Area ft' or perimeter (ft) I Load (Btuh) I Area ft' or perimeter (ft) I Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 Ww 13A4ocs 0.143 n 4.00 2.19. 456 397 1596 869 0 0 0 0 F-G 1A-riam 1.270 n 35.55 26.39' 19 ❑ 683 507 ❑ 0 D 0 1Ar1om 1.270 n 35.55 26.39 19 0 683. 507 0 0 0 0' ((--G D J1D0_ 0.390 n 10.92 10.34 20 20 223 211 0 0 0 0 11 13A-4ocs 0.143 a 4.00 2.19 384 354 1417 775 88 68 271 148 1A-rlom 1.270 a 35.56 49.72 10 1 341 477 0 0 0 0 I -D 11DO 13A-4ocs 0.390 0.143 _ e s 10.92 4.00 10.34 2.19 20 456 20 437 223 1749 211 956 20 32 20 32 223 128 211 70 11d I-G 1A-riom. 1.270 .s 35.56 26.39 19 19 683. 507 OI 0 0 0 13A-4ocs 0.143 w 4.00 2.19 384 354 1417 775 0 0 0 0 1A-rlom 1.270 w 35.56 49.72 10 1 341 477 0 0 0 0 D 11DO. „ 161B-30ad _ 0.390 0.032 .,w = 10.92 0.90 10.34 _ 1.66 20 , , 2196 .. 20. 2196 223 , 1968 211 3514 .0 _ 110 0 110 0 99 0 176 C F _ 22A4pl 0.989 - 27.69 _ 0.00 2196 210 5815 0 110 15 _ 415 0 6 c) AED excursion 0 13 Envelope loss/gain 17356 9994 11361 592 12 a) Infiltration 2883 772 206 55 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 25 5750 1 230 Appliances/other 5200 500 Subtotal (lines 6 to 13) 202401 21717 1341 1377 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 20240 21717 1341 1377 15 Duct loads 38% 44% 7666 9506 38% 44% SOB 603 Total room load 279061 312221 I I 1850I 1979 Air required (cfm) I I I 1500 1500 99 95 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Of&- 2021,1an-2512:15:45 ijGC:Fi m = - w �• RightSuiteOUnivers31201919.021RSU08101 Page ...nts\Wrightsoft HVAC\Johnson Residence Ave Q.rup Calc = MJB Front Door faces: N -- wrightsoft, Right-J® Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL W46 Phone: 772466-6799 Email: quickcalcs@aol.com 1 Room name Kitchen Blaster Bedroom 2 Exposed wall 1.0 It 14.0 It 3 Room height 8.0 ft heat/cool 8.0 ft heaUcoDI 4 Room dimensions 1.0 x 224.0 ft 15.0 x 14.0 ft 5 Room area 224.0 fN 210.0 ft' T Y Construction number I U-value (Btuhua F Or I HTM {BtuhNt') I Area ft' or perimeter (ft) I Load (Btuh) I Area ft' or perimeter (ft) I Load (13tuh Heat C001 Gross N/P/S Heat Cool Gross N/P/S Heat I Cool 6 13A4ocs 0.143. n 4.00 2.1.9 u 0 0 D 0 0 0 0 0' to-rlom 1.270 n 35.56 26.39' 0 0 0 0 0 0 0 0 1A-rlom 1.270 rt 35.56 26.39 0 0 0 0 0 0 0 0 D '11130 0.390 n 10:92 10.34 0 0 0 0 0 0 0, 0 11 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 112 102 410 224 1A-r'lom 1.270 a 35.56 49.72 0 0 0 0 10 1 341 477 D 11 D0 13A-4ocs 0.390 0..143 a s %92 4.00 10.34 2.19 0 8 0 8 0 32 0 18 0 0 0 0 0 D 0 0 V�f L-( 1A-Nom 1.270 0.143 s w 35.56 4.00 '26.39 2.19 '. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V�13A-4ocs 1A-r10m 11DO 161137;30ad . 1.270 0.390 0.032 w w - 35.56 10,92 0.90 49.72 10.34 1.60 0 0 224 0 0- .: -224 0 0 , 201 0 0 358 0 0 210 0 0 210 0 0 188 0 0 336 D C F 22A4DI 0.989 - 27.69 0.00 224 1 28 0 210 14 388 .0 6 c) AED excursion -27 z3 Envelope loss/gain 260 349 1327 1014 12 a) Infiltration U 4 192 51 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 2000 Soo Subtotal (lines 6 to 13) 274 2813 1519 2426 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 274 2813 1519 2426 15 Duct loads 38% 44% 104 1231 38% 44% 576 1062 Total room load 3781 41"1 I I 20951 3487 Air required (cfm) I I I 20 194 113 168 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr+phi of Right -Suite@ Universa12019 19.021 RSU08101 2021�1an-25 1Pa9 e 2 ...nts\Wdghtsoft HVACIJchnson Residence Ave Q.rup Calc = MJ8 Front Door faces: N 9 -� wrightsoft° Right-JO Worksheet Job: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com 1 Room name Master Bath Foyer 2 Exposed wall 29.0 ft 6.0 ft 3 Room height 8.0 ft heat/cool 6.0 ft heat/cool 4 Room dimensions 1.0 x 159.0 ft 6.0 x 8.0 ft 5 Room area 159.0 ft' 48.0 fN T Y Construction U-value Or I HTM I Area ft' ( ) I Load Area ft' ( ) I Load number (BtuhRt'= F (BtuhflN) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Grass I NIP/S I Heat I Cool Gross N/P/S Heat Cool 6 13A-4oc's 0:143 n 4.00. 2.19 120 120 480 263 46 28 111 60. 1A-r1om `' 1'.270 n 35.56 26.39 0 0 0 0 0 0 0 0 IA -Morn 1;270 n 35.56' 26.39 0 6 0 0! 0 0 0 0 DD .11DO., 0.390 n 10.92 10.34 0 . „ ` 0 0 0 20 20 ', 223; 211 11 VLG13A11ocs 0.143 a 4.00 2.19 88 88 352 193 0 0 0 0 1A-Flom 1.270 a 35.55 49.72 0 0 0 0 0 0 0 0 D 11D0 0.390 e 10.92 10.34 0 0 0 _0 0 0 _., ,. _ 0. 0 �/{- 13A-4acs 0.143 „ s 4.00' _ 2.19 0 _ _ A 0: 0 0 0 0 0 L._ 1A-rl om_ 1270 _ 's " 35.56 26.39 0 . 0 0 0 0 '... _ " 0 0 0' 13A-4ors 0.143 w 4.00 2.19 24 24 96 53 0 0 0 0 1A-rlom 1.270 w 35.56 49.72 0 0 0 0 0 0 0 0 --G �D 11DO 0.390 10.92 10.34 0 0 0.__ 0 0. .,_ 0.... 0 0 C 168-30ad '. , _ 0:032 ..w. . =" 050 ' 1.60 : ... . 159 159 ... 142 .. ' :.254 48 48 43.:. 77 F 22A-(pl' 0.989 - _ 27.69 0.00 . 159 .. , 29 .803, _ _ .... 0 48 6 .. _.. 166 0 6 c) AED excursion 1 -10 -6 Envelope loss/gain 1874 752 542 342 U a) Infiltration 398 107 82 22 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 Appllances/other 0 0 Subtotal (lines 6 to 13) 2273 1088 625 694 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2273 1088 625 594 15 Duct loads 38% 44% 861 476 38% 44% 237 260 I Total room load I I I 3133I I 1565I I 1 I I 861 I I 855 Air required (cfm) I I I 168 75 I 46 41 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed, -i wrlght .otc` 202Wan-2512:15:45 ^> - RightSuiteDUnivem12019 19.0.21 RSU08101 Page ...nts\WHghtsoft HVAC\Johnson Residence Ave Q,rup Calc = MJ8 Front Door faces: N r- wrightsoft• Right-J® Worksheet Entire House Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com Job: Date: By: 1 Room name Dining Living Room 2 Exposed wall 0 It 11.0 ft 3 Room height 8.0 ft heat/cool 8.0 It heat/cool 4 Room dimensions 6.0 x 12.0 ft 1.0 x 208.0 ft 5 Room area 72.0 ft' 208.0 ft' T y Construction U-value Or I HTM I Area ft' I load I Area ft' I Load number (Btuh/ft'= F (Btuh/fN) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S j Heat Cool j Grass N/P/S j Heat Cool 6 13A-flocs 0.143 n' 4.00 2.19 0 0 0 0 88 69 275 11 5 1A41om 1.270 n 35.56 26.39 0 0 0 0 0 0 0 0 V 1A-rlom 1.270 n 35.56 26.39 0 0 0 0 19 0 683 507 D 11D0 0,390. n 10.92 10.34 0 0 0 0 0 0 0 0 VLG13A-4ocs 11 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlom 1.270 a 35.55 49.72 0 0 0 0 0 0 0 0 D 11DO 0.390 a 10.92 10.34 _ 0 0_ 0 0 0 0 0 0 Vv 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 L-f 1 A41 om " .. 1.270 s " 35.56 ' _ :26.39 . 0, 0 . 0 :` 0 0 0 _ 0 0 wjr---G 13A-4ocs (1.143 w 4.00 2.19 0 0 0 0 0 0 0 0 IA-rlom 1.270 w 35.56 49.72 0 0 0 0 0 0 0 0 c-D 11D0 0.390 w_. 10.92 10.34 0 0 _ _ . 0 , _ 0 0 0 ._0 0 C 16B•30ad: 0.032 _ 0.90 . 1.60 .. . _ 72 72 65 , ,: 115 1208 20B 186 333 F 22A-tp1 0.989 - 27.69 0.00 72 0 0 0 208 11 .305 0 6 c) AED excursion -10 1 1 -23 Envelope loss/gain 65 105 1 1449 967 12 a) Infiltration 0 0 151 40 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 4 920 2 460 Appliances/other 0 900 Subtotal (lines 6 to 13) 65 1025 1600 2368 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 4 7 14 Subtotal 65 1025 1604 2375 15 Duct loads 38% 44% 24 449 3B% 44% 608 1039 Total room load 1191 14741 2212 34141 Air required (cfm) I I I 5 71 I I 119 I 164 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlgl�>r�ots* 2021-Jan-2512:15:45 �,..y Right-Suite®UnivemI2019 19.021 RSU081.01 Page ntsUnghtsoft HVACWohnson Residence Ave Q.rup Calc = MJB Front Door faces: N r- wrightsoft' Right-JO Worksheet Entire House Quick Calm Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com Job: Date: By: 1 Room name Bedroom 2 Bath 2 2 Exposed wall 12.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 It heat/cool 4 Room dimensions 12.0 x 16.0 ft 5.0 x 8.0 ft 5 Room area 192.0 ft' 40.0 ft' T Y Construction U-value Or I HTM I Area ft° I Load Area ft' Load number (Btuh/M- F (Btuhflt') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 6.143 n 4.00 2.19 0 0 0 0 0 '0 0 0 1A-r1om 1.270 n 35.56 26.391 0 D 0' 0 0 0 0 0 IA-rtom 1.270 n 35.56 26.39 0_ 0 0 0. 0 0 0 0 D 11DO 0.390 n 10.92 10.34 O 0 0 0 _0 0' 0 0 11 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlom 1.270 a 35.56 49.72 0 0 0 0 0 0 0 0 D 11D0 0.390 a 10.92 10.34 0 D 0 0, ,.. 0 0 0 0 Val 13A-4ocs 0.143 .s 4.00 2.19 96 86 346 186 0 0. 0 0 to-rlom 1.270 s 35.56 AM 10: 10. .. 341 253 0 0, 0 0. w 13A4ocs OA43 w 4.00 2.19 0 D 0 0 0 D D 0 I--G 1Atiom 1.270 w 35.56 49.72 0 0 0 g 0 0 0 0 D 11 DO 0.390 w. 10,92 10.34 0 0 D _ 0 0 D 0 0 C 16B-30ad 0.032 - 0.90' _ 1.60 192 192 172 307 _ 40 40 36 64 F 22A4vI 0.989 , - 27.69 0.00 _ 192 12 332 _ 0 40 0 _ 0 0 6 c) AED excursion -12 .3 Envelope lass/gain 1 1192 738 36 1 61 12 a) Infiltration 165 44 0 u b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 1356 1242 36 291 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 18 6 11 14 Subtotal 1367 1260 42 303 15 Duct loads 36% 44% 518 551 38% 44% 16 132 Total loadI 1101I 18871 5311 435 Air rrequired (cfm) I I I I 21 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -FW wrlgfat-+ott* 2021-Jan-2512:15:45 W..-, - RightSuite(DUniverw12019 19.021 RSU08101 Page nts\Wrightsof HVAC\Johnson Residence Ave Q.rup Calc = MJ8 Front Door faces: N XL Job: rF wrightsoft, Right-J® Worksheet Date: Entire House Date: By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcaics@aol.com 1 Room name WIC 2 WIC 3 2 Exposed wall 0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/CODI 4 Room dimensions 5.0 x 4.0 ft 5.0 x 4.0 ft 5 Room area 20.0 ft' 20.0 f? T Y Construction U-value Or I HTM I Area ft' I Load I Area ft' I Load number I (Btuh/ft'=F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPIS Heat Cool Gross NIPIS Heat Cool 6 VVVIIlll7 13A-4acs. 0i143 n 4.06 '2.19 D 9 D 0 0 -0 Q 0. ;1A-Horn 1.270 n 35.56 26.39 .0 0 0 0 0 0 0 0 IA-riom 1.270 ,n 35.56 26.39' 0 0 0 0 0 0. 0 0 _. D 111130 0:390 . .n 10.92 ' _ 10.34 6 ,. .. `, 0 0. 0 . .. A 0 0 0, 11 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 1A-riom 1.270 a 35.56 49.72 0 0 0 0 0 0 0 0 D 11DO 13A-flocs 0.390 0.143 a s _10.92 4.00 10.34 2.19 0 0 0 0 0_ 0 , 0 0 0 - 40 0 40 ._ - 0 160 0 88 .1Ariom 13A-4ocs 1270 0.143 s w 35.56 4.00 `. 2s.39 2.19 0 0 0 0 0 0 _. 0 0 .0 0 ll 0 0 0 0 0 1A-riom 1.270 w 35.56 49.72 0 0 0 0 0 0 0 0 D 11D0 0.390 w 19.92 10.34 0 .. .. 0. 0 . - ... 0, 0 _ -., . - . D . _ _..... 0 -_ 0. C .- . 16B-30ad _ = 0.032 .. _= , "0.80.. _ . 1.60 20 ` .., 20, .. 18 - _ 32 ;, 20 .. :' 20 : 18. ; .. 32 F . 22A4PI 0.989 . - .. 27.69 - _ , 0.00 .. 20 .. 0 0 _ .0 . .. . 20 . 5 ._ 138 _ 0 61 c) AED excursion 1 0 -1 Envelope loss/gain 18 32 1 1 317 118 i2 a) infiltration 0 0 69 ib b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 18 32 385 137 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18 32 385 137 15 Duct loads 38% 44% 7 14 38 % 44% 146 60' 21I 42I 529I 199 l Airrequomdl(�) I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 'a' wright�oft` 2021-Jan-2512:15:45 .« ••-� RightSuite®Universal2019 19.021 RSU08101 Page nts\Wrightsoft HVAC1Johnson Residence Ave Q.rup Caic = MJ8 Front Door faces: N +td- wrightsoft• Right-J® Worksheet Entire House Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 r=mail:quickcalcs@aol.com Job: Date: By: 1 Room name Bedroom 3 Bath 3 2 Exposed wall 28.0 ft 5.0 ft 3 Room height 8.0 ft heat/coal 8.0 ft heat/cool 4 Room dimensions 12.0 x 16.0 ft 9.0 x 5.0 ft 5 Room area 192.0 ft' 45.0 ft' T Y I Construction U-value Or I HTM I Area ft' I Load I Area ft' I Load number (Btuh ft'-F (Btuh/fN) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V1 n 4.56 0 0 D 0 0 0 0 0 IIA-dots 1A-ri'om 1.270 1.270 n 35.56 6.19 26.39 0 0 0 0 D 0 A 0 1A41 om 1.270 n 35.56 26.39 0 0 0 0, 0 0 0 0 I_ D 11D0 _ 0.390 n 10.92 10.34 0 0 .0 0 0 0 0 0 11 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 1A-rlam 1.270 a 35.56 49.72 0 0 0 0 0 0 0 0 11D0 0.390 a 10.92 10.34 0 0_ 0 0 0 0 0 0 V" 13A-4acs 0.143 s 4.00 2.19 96 86 346 1189 0 0 0 0 ;1A-riam Al 270 s' : _ 35.56 '..26.39 _ _ '._ 10 10 . 341 .. .253 . 0 0 .' 0 0 13A-4ocs 0.143 w 4.00 2.19 128 128 513 280 40 40 160 88 1A{iom 1.270 w 35.56 49.72 0 0 0 0 0 0 0 0 D 11 DO 0.390 w_ 10.92 10.34 0 D 0 0 D_ 0_ 0 0 C 1& 630ad 0.032 _ 0.90 1.60 192 192 172 307.. 45 45 40 72 F 22A4vI 0.989 , - 27.69 _ " 0.00 192 28 775 -.0 45 _ 5 138 0 6 c) AED excursion -15 1 1 -4 Envelope loss/gain 2147 1014 339 156 12 a) Infiltration 384 103 69 18 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 2532 1577 408 404 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 4 7 6 11 14 Subtotal 2536 1584 414 415 15 Duct loads 38% 44% 960 693 38% 44% 157 182 Total room load 34161 22711 5711 5971 Air required (cfrn) I I I 188 109 I I 31 29 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A&- wrlghlk-.otPi^ 202Wan 25 12:15:45 PightSuiteSUniverw12019 19.021 RSU08101 Pagel ...nts\Wrightsoft HVAC\Johnson Residence Ave Q.rup Calc = MJ8 Front Door faces: N wrightsoW Right-J® Worksheet Entire House Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com Job: Date: By: 1 Room name Bedroom 4 Bedroom 5 2 Exposed wall 27.0 ft 10.0 ft 3 Room height 8.0 it heat/cool 8.0 ft heat/coal 4 Room dimensions 1.0 x 159.0 ft 1.0 x 161.0 ft 5 Room area 159.0 ft' 161.0 ft Ty Construction U-value Or I HTM I Area (ft') I Load I Area (ft') I Load number (Btuh/fN= F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V 1 13A-4ocs 0.143 n 4.06 ' 2.19 , 120 110 442 242 80 76 262 154 , 1A-r1am 1.270 n 35.66 26.39 10 0 341 253 10 0 341 253 - 1A-rlom 1.270 n 35.56 26.39 0 0 0 0 0 0. 0 0 (((G D 11DO 0.390: n 10.92 ..10.34 0 0 0. 0 :0. 0' 0 0 19 13A-4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 tA-rlom 1.270 a 35.55 49.72 0 0 0 0 0 0 0 0 D 11DO 0.390 e 10.92 10.34 0 0 0 0 0 0. 0 0 T-G 13A-4ocs 0.143 _ s 4.00 2.19 0 0 0 0. 0 0 0 0 _IA-riom. 1.270 s 35.56 26.39 0 0 .0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 96 96 384 210 0 0 0 (1 IA-riorn 1.270 w 35.56 49.72 0 0 0 0 0 0 0 0 D 11DO 0.390 w, 10.92 10.34 0 0 0 0 0_ 0_. 0 0 C 16BS0ad 0.032 . - _ 0.90 1.60 ,159 159 142 254 161 161 144 258 F 22A-tpl 0.969 - 27.69 0.00 159 27 748 .0 161 10 _ 277 0 6 c) AED excursion -14 -11 Envelope loss/gain 2058 945 1 1 1044 654 iz a) infiftration 371 99 137 37 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 2429 15D4 1182 1151 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 4 7 19 34 14 Subtotal 2432 1511 1201 1185 15 Duct loads 38 % 44 % 921 661 38 % 44% 455 519 r r r r 3180I r 2104 r r r 1689 r i 1782 Air requomdl `cads) I I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. AM- wright- cbVt" 2021-Jan-2512:15:45 -- _- -- RightSuite@Univerw1201919.021RSUD8101 Page ...nts\Wdghtsoft HVAC\Johnson Residence Ave CLrup Calc = MJ8 Front Door faces: N -�- wrightsoftt Right-J® Worksheet Entire House Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Email: quickcalcs@aol.com Job: Date: By: 1 Room name Hall Family Room 2 Exposed wall 0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heaUcoDI 4 Room dimensions 1.0 x 60.0 ft 23.0 x 12.0 ft 5 Room area 60.0 ft' 276.0 fP T y Construction U-value Or I HTM I Area ft' I Load I Area ft' I Load L I number (Btuhlft'= F (Btuh/ft') or perimeter (ft) (Btu or perimeter (ft) (Btuh) Heat Cool Gross N/P/S j Heat Cool j Gross N/P/S j Heat Cool 6 13A-4ocs 0.143 n 4.00 2.19 0 I 0 0 I 0 0 I 0 0 6 IA-rlom 1.270 n 35.56 26.39 0 0 0 0. 0 0 0 0 1AA1om 1.270 n 35.56 26.39 0 0 0 0. 0 0 0 0 D .11DO 0.390 n 10.92 10.34 - 0 6 0 0, 0 0' 0 0 11 VLG13A-4ocs ,. 0.143 a 4.00 2.19 0 0 0 0 96 96 384 210 1Aa'1om 1.276 a 35.56 49.72 0 0 0 0 0 0 0 0 D 11130 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 1/� tt 13A-4ocs 0.143 s 4.00 2.19 0 0 .0 0 194 184 737 403 1A:riom_ 1:270 ..s: 35.56 26.39 _' ._ - 0 0' 0 _ 0 0 0 0 0 G 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 96 66 264 144 1Aqiom 1.270 w 35.66 49.72 0 0 0 0 10 1 341 477 D 11 DO 0.390 w _ 10.92 10.34 0 0 0 0 20 20 223 - 211 C 16B-30ad 0.032 -. 0.90 -, ' 1.60 60 _ 60 54 96 _ . 276 276 - 247 442 F 22A-tDI 0.989 „ - 27.69 _ 0.00 60 . , . 0 0 0 276. 47 130.2 , 0 6 c) AED excursion -1 174 Envelope loss/gain 54 95 3498 2061 12 a) infiltration 0 u 645 173 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 900 Subtotal (lines 6 to 13) 64 95 4144 3594 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -54 -95 0 0 14 Subtotal 0 0 4144 3594 15 Duct loads 38% 44% 0 0 38% 44% 1569 1573 Total room load DI OI 57131 5166 Air required (cfm) I I I 0 0 I I 307 248 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. A -F- wright .oi t- 2021-Jan 25 12:16:46 PightSuite@)UniversR12019 19.021 RSU08101 Page ntslWrightsoft HVACUohnson Residence Ave Q.rup Calc = MJ8 Front Door faces: N -- wrightsoft Duct System Summary JoDate: Entire House By: Quick Calcs, Inc. 317 St Lucie Lane, Fort Pierce, FL 34946 Phone: 772466-6799 Emit quickcalcs@aol.com aInformation For. Jefferson Residence 4501 Avenue Q, Fort Pierce, FL 34947 External static pressure Pressure lasses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.272 in/100ft 1500 cfm 184 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.272 in/100ft 1500 cfm Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath 2 c 435 3 21 0.281 4.0 Ox 0 VIFX 42.8 135.0 st5 Bath 3 h 571 31 29 0.278 4.0 Ox 0 VIFX 44.5 135.0 st5 Bedroom 2 h 1884 101 87 0.347 7.0 Ox 0 VIFx 29.2 115.0 st2 Bedroom 3 h 3496 188 109 0.276 8.0 Ox 0 VIFX 46.4 135.0 st5 Bedroom 4 h 3354 180 104 0.272 8.0 Ox 0 VIFX 49.0 135.0 st6 Bedroom 5 h 1656 89 82 0.279 6.0 OX 0 VIFX 44.0 135.0 st6 Dining c 1474 5 71 0.364 6.0 OX 0 VIFx 22.2 115.0 st3 Family Room h 2857 154 124 0.385 7.0 OX 0 VIFX 15.0 115.0 st1 Family Room -A h 2857 154 124 0.374 7.0 Ox 0 VIFX 18.7 115.0 st1 Foyer h 861 46 41 0.364 5.0 OX 0 VIFX 22.2 115.0 st3 Kitchen c 2022 10 97 0.383 6.0 Ox 0 VIFX 15.7 115.0 st1 Kitchen -A c 2022 10 97 0 0 Ox 0 VIFx 0 0 Laundry h 1850 99 95 0.392 6.0 Ox 0 VIFx 12.7 115.0 st1 Living Room c 3414 119 164 0.354 8.0 Ox 0 VIFx 26.2 115.0 st3 Master Bath h 3133 168 75 0.372 8.0 Ox 0 VIFx 19.2 115.0 st4 Master Bedroom c 3487 113 168 0.381 8.0 Ox 0 VIFX 16.4 115.0 st4 wlc 2 c 46 1 2 0.331 4.0 Ox 0 VIFx 36.0 115.0 st2 wlc 3 h 531 29 9 0.325 4.0 Ox 0 VIFx 38.6 115.0 st2 i► - - wrightsoft" RlghtSulte®UnivermI201919A21RSU08101 ...ntsUrightsoft HVACUchnson Residence Ave Q.rup Calc = MJB Front Door faces: N 2021,ian-25 12:15:45 Page 1 Name Trunk Type Htg (cfm) Clg (Cfm) Design FIR Velar. (fpm) Diam (in) H x W (in) Duct Material Trunk st5 Peak P.VF 222 159 0.276 502 9.0 0 x 0 VinlFix st2 st2 Peak AVF 353 258 0.276 449 12.0 0 x 0 VinlFlx st6 Peak AVF 269 186 0.272 494 10.0 0 x 0 VinlFlx st3 st3 Peak AVF 439 462 0.272 588 12.0 0 x 0 VinlFlx st4 Peak AVF 281 243 0.372 515 10.0 0 x 0 VinlFlx st1 Peak AVF 417 440 0.374 561 12.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1500 1500 0 0 0 0 Ox 0 VIFx -* wrightsoft' 2021,1an-2512;15:45 RlghtSuite®Unlversa12019 19.021 RSU08101 Paget ...nts\Wdghtsoft HVAC\Johnson Residence Ave Q.rup Calc = MJ8 Front Door faces: N