Loading...
HomeMy WebLinkAboutKSM Compaction signedHeadquarters IWCPIk Ar 11345 U.S. Highway 1 Sebastian, FL. 32958 &J ILVL Orlando 723 Progress Way Sanford, FL. 32771 August 11, 2021 CONTRACTOR: JOB LOCATION: PERMIT #: To Whom it may concern, Harris Homes 1409 SW Aachen Avenue Port St. Lucie, Florida 4940 Watersong Way Fort Pierce, Florida ENGINEERING AND TESTING Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB # : 216244-1d/JM/jam Enclosed, please find the nuclear density test results performed on the Stemwall Backfill at the above referenced project. Should you have any questions, please feel free to contact our office. Respectfully, Digitally signed by This item has been electronically signed and Julie Keller sealed by Julie Keller, P.E. FI. lic. I'll, on the date stated directly to the right using a digital signature. Date Printed copies of this document are not nsidered signed and sealed and the =ignaturemostbe—iRedonanyelectronic Copies. 2021.08.11 14:20:24 -04'00' Julie E. Keller, P.E. President PE # 68366 Email: gregharrisfl@gmail.com 08/11/21 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 DATE TESTED: PERMIT #: CONTRACTOR: JOB LOCATION: 1P40Ik 9 ENGINEERING 17AVL AND TESTING SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 August 10, 2021 Harris Homes 4940 Watersong Way Fort Pierce, Florida Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #: 216244-1d/JM/jam NUC # 215 Nuc Model: MC-IDR-P Nuc Serial #: MD80404215 ITEM TESTED: Stemwall Backfill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1 N.W. Garage 0" - 12" 15D 111.2 114.5 97.1% 2 S.W. Porch 15D 111.0 96.9% 3 N.W. House 15D 112.4 98.2% 4 Center House 16D 113.7 99.3% 5 S.E. House 16D 114.1 99.7% 6 N.E. House 15D 111.5 97.4% 7 S.W. House 15D 112.2 98.0% Soil Description: Light Brown Sand with Some Shell Fragments and Traces of Clay In Place Moisture: 11.6% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 114.5 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Disclaimer: Contractor is responsible to maintain Minimum Requirement the tested area in the condition that KSM for Staked Foundation completed the indicated passed compaction test. KSM is not responsible if the tested area has been Julie E. Keller, P.E. President altered from the approved inspected condition. PE # 68366 8/11/2021 Email: gregharrisfl@gmail.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WEE Headquarters 1W C Sk � ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 17 LVL AND TESTING Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 ASTM D 1557 KSMengineering.net DATE TESTED: August 10, 2021 KSM JOB # : 216244-1d/JM/jam PERMIT #: CONTRACTOR: Harris Homes JOB LOCATION: 4940 Watersong Way Fort Pierce, Florida 116.0 I I I I I I I W E I I I I I I I I i115.0 —1.—..—...—..—..�.._..� .._.._, G I I I I I I I H T114.0—..—.. ....... —.. I.._..—�.—..—..—.. �..—..—, I I I I I I I P I I I I I I I I 113.0 T—..—....—..—j._..—...—..—..�—....—..—. C I I I I I I I I F 112.0 ._.._..L_.._..1.._.._. D I I I I I I I I F: 111.0 i _.. i.._. _.I._.._..i _.. i.._.._i._.._..i _.. i.._.._. Y I I I I I I I I 110.0 1— ._.. _.._._.._...._...._.._j._.._..�.._...._.._. I I I I I I I I 109.0—..—.. �..—..—�.—..—..� —.. �..—..—�.—..—..� —.. �..—..—� 7 8 9 10 11 12 13 14 15 Moisture - % of Dry Weight Soil Description: Light Brown Sand with Some Shell Fragments and Traces of Clay Proctor Optimum Moisture: 12.0 % Proctor Max. Dry Density: P.C.F. 114.5 Julie E. Keller, P.E. President PE# 68366 8/11/2021 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE