HomeMy WebLinkAboutTriangle Testing Lab report TRIANGLE TESTING LAB, INC. RECEIVED FL REG.#3101 4750 ROYAL PALM BEACH BOULEVARD WG 2 $ NZI WEST PALM BEACH, FLORIDA 33411 (561)790-3049 _ ,Ode r e-mail: triangle2992t&_gmail.com Date: August 20, 2021 To: St. Lucie County Building Department Re: Soil Compaction Report-Density of In-Place Compacted Soil SYNERGY HOMES - RESIDENCE 113 LIMA COURT PORT SAINT LUCIE, FL Test Date Test# Test Location Elevation In-Place Readings MMPD Values % Density Moisture Density Moisture 08/04/21 1 Southeast Area 1'-2' 105.9 9.3 109.5 5.6 96.7 08/04/21 2 Center Area 0-1' 106.5 9.0 109.5 5.6 97.3 08/04/21 3 Northwest Area 1'-2' 105.8 9.3 109.5 5.6 96.6 Remarks:All elevations are measured from top of pad grade. (Mod Proctor Test#1) Verification Statement This statement shall serve as verification that the soil beneath the proposed structure has been tested in accordance with Section R401.4 of the 2020 Florida Building Code, Residential edition. The tests were conducted from the existing grade. Density tests were taken at a minimum of three (3) locations throughout the total depth of fill.The depth of fill was approximately 2.0 feet. The foundation setbacks were based on information furnished by the client, at the time of testing. Based on the location and depths tested, we verify that the fill has been compacted to a minimum of 95% of the maximum dry density as determined by ASTM D-1557 and that the minimum soil bearing value beneath the proposed foundation area'is 2,500 pounds per square foot. Respectfully submitted, ENJC' F ichard Boyette; FL PE 4424• 42485 = Vice President August 20, 2021 = ' STATE OF 4w File#23435 ,',�?^�,^•.•" . �C; Permit#21050546 i TRIANGLE TESTING LAB, INC. FL REG.#3101 4750 ROYAL PALM BEACH BOULEVARD WEST PALM BEACH, FLORIDA 33411 (561)790-3049 e-mail: triangle2992(c_gmail.com Date: August 20, 2021 To: St. Lucie County Building Department Re: Soil Compaction Report-Density of In-Place Compacted Soil SYNERGY HOMES - RESIDENCE 113 LIMA COURT PORT SAINT LUCIE, FL Test Date Test# Test Location Elevation In-Place Readings MMPD Values % Density Moisture Density Moisture 08/04/21 1 Southeast Area V-2' 105.9 9.3 109.5 5.6 96.7 08/04/21 2 Center Area 0-1' 106.5 9.0 109.5 5.6 97.3 08/04/21 3 Northwest Area V-2' 105.8 9.3 109.5 5.6 96.6 Remarks:All elevations are measured from top of pad grade. (Mod Proctor Test#1) Verif►cation Statement This statement shall serve as verification that the soil beneath the proposed structure has been tested in accordance with Section R401.4 of the 2020 Florida Building Code, Residential edition.The tests were conducted from the existing grade. Density tests were taken at a minimum of three (3) locations throughout the total depth of fill. The depth of fill was approximately 2.0 feet. The foundation setbacks were based on information furnished by the client, at the time of testing. Based on the location and depths tested, we verify that the fill has been compacted to a minimum of 95% of the maximum dry density as determined by ASTM D-1557 and that the minimum soil bearing value beneath the proposed foundation area is 2,500 pounds per square foot. Respectfully submitted, "f� 13 0,�,,,�, GENg Richard Boyette,7FLPE#4:85' 42485 - Vice President August 20, 2021 = STATE of o;��o�. a File#23435 r ljllli111f1111\\l Permit#21050546