Loading...
HomeMy WebLinkAboutMaster Anchoring Planr ®� o� TABLE 1 - 170D ®'®' ANCHORING TO CONCRETE _ SHED WIDTH MAXIMUM ANCHOR SPACING ' = 24.1-011 4'-011 1 20' —0" 61-01$ TYPE 1 TYPE 2A TYPE 213 30" DRIVE 30" AUGER 30" AUGER 16' — 0" 61-611 ANCHOR ANCHOR ANCHOR FOR ROCK/CORAL FOR SOIL/CLAY FOR SOIL/CLAY 14'-031 /% '-0f1 INSTALLED PER MANUFACTURER'S INSTRUCTIONS. > » f1 EYELET AT MAXIMUM OF 6" 12 —0 8 —� OPTIONALABOVE GRADE. 101_011 9'-01, TYPE 3 CONCRETE ANC80 ANCHOR , — $1 1 11 WITH OR W/O BRACKET —o TYPICAL ANCHOR TYPES 6'-0" 12'-0" 0 TIE —DOWN STRAP (SEE NOTES) TIE —DOWN STRAP BOLTED TO TYPE 3 ANCHOR WITH 1 /2" GRADE 5 BOLT MINIMUM WITH WASHERS 1/2"x3" (4,000 LB.) CONCRETE i WEDGE ANCHOR WITH U—CHANNEL I' V (TYPE 3) .. ° i (1) 4x4 SYP #2 ON 8' WIDE OR LESS. (2) 2x6 OR (1) 4x6 P.T. SYP #2 SKIDS ALL ELSE(CAN BE SET ON GROUND). ° EXISTING 4" CONCRETE TABLE 2 - 170 D 30" AUGER ANCHOR SPACING SHED WIDTH MAXIMUM ANCHOR SPACING UP TO 16'-011 8'-0" 16' -1 " TO 20' -0" 6'-0 " 20' -1 " TO 24' -0" 4'-0" TIE —DOWN STRAP BOLTED THRU FLOOR JOIST WITH 1 /2" GRADE 5 BOLT MINIMUM WITH WASHERS (NUT & BOLT OR jx2j" LAG BOLT) 1/2" x 30" EARTH ANCHOR WITH EYE HOLE: AUGER STYLE FOR SOIL/CLAY, DRIVE STYLE FOR ROCK/CORAL RECEIVED JUL Q 9.7.071 permitting DepartM" St, Lucie CO'1n�' (1) 4x4 SYP #2 ON 8' WIDE OR LESS. (2) 2x6 OR (1) 4x6 P.T. SYP #2 SKIDS ALL ELSE(CAN BE SET ON GROUND). 4" CONCRETE OR OPTIONAL SUPPORT PAD (P.T. WOOD, CONCRETE BLOCK OR PAD) SPACED AT 8'-0" MAX. 1. ANCHOR SPACING IS DESIGNED AS PER ASCE-7. 2. ALL MEASUREMENTS ARE CENTER —TO —CENTER. 3. TIE —DOWN STRAPS CAN BE MINIMUM: 1-4" x 0.035" GALVANIZED STEEL, FEDERAL SPECIFICATIONS QQS-781—H, TYPE-1, FINISH—B, GRADE-1 OR 1/4" STEEL CHAIN WITH MINIMUM 1,200 LB TENSILE STRENGTH 4. CONNECTING HARDWARE TO HAVE 4,725 LB. MINIMUM ULTIMATE CAPACITY (3,150 LB. x 1.5). 5. ALL EARTH ANCHORS SHALL HAVE A MINIMUM 4,300 LB. CAPACITY. 6. EARTH ANCHORS LOCATED AT EACH CORNER, MAXIMUM 16" FROM END (4 MINIMUM PER BUILDING), AND SPACED AS PER TABLE 2A,B,C DEPENDING ON SHED WIDTH, WIND SPEED, AND EXPOSURE. 7. CONCRETE ANCHORS TO BE SPACED AS PER TABLE 1A,B,C DEPENDING ON SHED WIDTH, WIND SPEED, AND EXPOSURE. 8. CONCRETE ANCHORS TO HAVE A MINIMUM OF 4" COVER (DISTANCE FROM ANCHOR TO EDGE OF CONCRETE). s. MINIMUM SOIL BEARING CAPACITY IS 2,000 PSF (TYP.) 10. EARTH ANCHORS AND CONCRETE ANCHORS MAY BE USED IN CONJUNCTION PROVIDED THAT THE SAME MAXIMUM SPACING IS FOLLOWED FOR EACH ANCHOR TYPE. 11. CONCRETE BLOCKS CAN BE OPTIONALLY CAPPED WITH APPROVED ABS CAP BOARDS (OLIVER TECHNOLGIES, INC. MODEL#OTIC81, OTIC82 OR EQUIVALENT) 12. HOLLOW OR SOLID CONCRETE BLOCKS (8"x8"x16") MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48" WITHOUT REINFORCING. ANCHORS NOT NEEDED ON ENDS. 0WAII'l IN'U STRIES, INC. CODE VERSION MANUFACTURER SWMLT SHEDS AGENCY WA BUILDING TYPE R OF LA ew CONSTRUCTION TYPE V-B FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY Ulum ALLOWABLE NUMBER OF STORIES 1 BASIC MIND SPEED V--17amph EXPOSURE 0 ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFICIENT +/- 0.16 IMPORTANCE FACTOR 1.0 ROOF DEAD LOAD 1CPSF ROOF LIVE LOAD 30PSF OR 30011, POINT LOAD FLOOR DEAD LOAD IOPSF FLOOR LIVE LOAD 75/125PSF 'R' RAnNG OF WALLS, FLOOR, ROOF N/A MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE No HURRICANE SHELTER USAGE NO SQUARE FOOTAGE 719 SO.Fr. OR LESS 1 I RENSED NOTES &CONCRETE ANCHOR I2/19/19 Mre z zazo Fec 1z/zs/zo MTe 7 0 - 0 _ .�l/1/21 Ld Matthew T. Baldwin P.E. � Florida License #64608 F5 Sheet: AP-1 OF 1 ) 111b. O20 A