Loading...
HomeMy WebLinkAboutResidential Heat Loss and Heat Gain CalculationPage 1 Residential Heat Loss and Heat Gain Calculation 8/13/2018 In accordance with ACCA Manual J Report Prepared By:. Central Air Systems Inc. For: Design Conditions: West Pam Beach Indoor: Outdoor: Summer temperature: 70 Summer temperature: 90 Winter temperature: 70 Winter temperature: 42 Relative humidity: 55 Summer grains of moisture: 127 Daily temperature range: Medium Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Duct 711 0 711 719 Floors 1,048 0 1,048 1,864 Walls 1,376 0 1,376 1,632 Ceilings 1,977 0 1,977 1,538 People 1,200 920 2,120 0 Fireplaces 0 0 0 0 Misc 1,200 0 1,200 0 Windows 4,317 0 4,317 1,568 Doors 483 0 483 573 766 89 Skylights 0 00 0 Infiltration 1,858 3,848 5,706 6,305 Whole House 14,936 4,768 19,704 15,090 (1.5tons) HVAC-Cale Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only, actual loads may vary due to weather and construction differences. ove r®'P"*'i