HomeMy WebLinkAboutTANK SPECS - 8-18-21o
Quality Steel Corporation AG/UG Propane Tanks
7919T
1450 wg. AND UP
APPROXIMATE ABOVEGROUND/UNDEGROUND (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS
WATER
CAPACITY
DIAMETER
(OD)
HEAD
TYPE
OVERALL
LENGTH
OVERALL
HEIGHT
LEG*
WIDTH
LEG**
SPACING
121-101/211
WEIGHT
(lbs.)
**QUANTITY
FULL LOAD
PER STACK
*120 wg.
24"
Ellip.
5'-8"
3'
1'-11/2"
or 3'-11"
260
109 196
161 12
*250 wg.
30"
Heml.
7'-10"
3'-8"
1-S"
4'-11"
480
54
9
*320 wg.
30"
1
Hemi.
9'-7"
3'-8"
1'-5"
5'
620
45
9
500 wg.
371/2"
Hemi.
10'
V-2"
1'-8"
5'
950
37 130
8 j 6
1000 wg.
41"
Hemi.
16'
4'-5"
11-8"
10'-1"
1,800
17115
61 5
1450 wg.
461/2"
Ellip.
17'4"
4'-11"
1'-9"
11'-7"
2,650
12
4
1990 wo,
461/2"
Ellip.
23'-11"
4'-11"
1'-9"
16'
3,520
8
4
Dimensions and motions shown are approddmam Individual vessels may vary.
Lag spacing+/. 2". Leg widths and spaciftg may vary based on n fg. location. Check with your salesperson for detaris. 320, M. 320 w& sbndard tanks
- no betas In legs (one center hole an request). 500 and 1000 wg. standard tanks - 2 hales 16" an center. US0 w& and up as shown above.
" Full load and stack gum thies vary by shipping location. Check with your salesperson for details.
General Specifications
- Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section Vlll, Division 1.
Complies with NFPA 58.
- Rated at 250 psig from -20* F to 125* F. All vessels registered with National Board.
- Two service options available:
Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish
or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite
AG/UG dome.
Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid
applied epoxy primer coat followed by urethane top coat, supplied with steel AG/UG dome.
- All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel.
Updated June 30, 2015
' r
r
mom Nam zl" 0
.�i; i •� 1 'iT
a1?A/J Wt.I�
..i.....�-1..r,.i.-. ��• �� . , .._,_w-.mow '
• rJ.e*Vl n Yt
arf�..l�p
• •ram ew�lcar .
to - •
w••• 1 i
•' j�l '•let
• •1 ril
rA kW
-• t
. CQRiLO
ivt�a J411 *dome a Ow
s
' PROPANE CONSTRUCTION NOTES
1. All pipe and fittings above ground and inside building shalt be
SCH..40 Galvanized ASTM A120 or AGA approved.corrugated
stainless steel •(C.S.S.T.) pipe. ,
2. All polypipe and fY , hgs shall be ASTM D251.3 or ASTM D2517
and shall be bur" "outside underground at a depth of 18" with
warning We and tracer wire.
3. All pipe and meter loca€lons are approximate and subject to
change.. .
4. Ali polypipe shaft be Joined by heat fusion or approved mechanical .
couplings.
5. All'galvanized pie shall be dreaded.
s: Ail. pipe. shall be pressure tested to 20 PSI for a period of 24
hours.
r
• ' •X
UNDERGROUND TANK INSTALLATION
2" to G"
• DOWNGRADED AWAY ..
• FROM DOME
°r . • ..� Mi • s•• ; .;
{" try, '•� i. • i�
I ANODE CABLE •" :'` • •-:-
SACR.IFICIAL ANODE - :.,••�• _ ;•
• (MAGNESIUM BApj �: •�.
•
REGQGATOR
•
SMUT GAS OFF AT
'
•
' GU UDE VALVE
.x
WIS O
• • •
HAR)l fW TAPE'
�
• RISE
s
GRADS/CONCRETE SLEEVE
:
•
O . .0 • . • •��r�•• O
�I! �•r••O•
'' ••••t •I.��••' • 0 f •wv
�• •�
�•
dp of
- ..
, x
r . • r . J p �•�.
o
I • a• �; •• w.� .•• • . i' O �.
•at. .
Ir
• V • r — •
ramN
v i_
• • . V • I •
f :?
o
.° UN04110nou119
tt•OAS CORTAWLft SERVICE LINEFLU
•
' TRACE iilRi
'