HomeMy WebLinkAboutProducts Review; Residential Standby Generators20/22 kW
INCLUDES:
• True Power- Electrical Technology
• Two-line multilingual digital LCD Evolution'" controller
(English/Spanish/French/Portuguese)
• 200 amp service rated smart switch transfer switch available
• Electronic governor
• Standard Wi-Fi® connectivity
• System status & maintenance interval LED indicators
• Sound attenuated enclosure
• Flexible fuel line connector
• Natural gas or LP gas operation
• 5 Year limited warranty
• Listed and labeled by the Southwest Research Institute allowing
installation as close as 18 in (457 mm) to a structure.'
'Mustbe located awayfrom doors, windows, and fresh air intakes and in
accordance with local codes.
https:/lassets.swri.org/library/DirectofyOfListedProducts/
Construclionlndustryl973_DoC_204_13204-01-01 _Rev9. pdf
FEATURES
9
7
X
INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Gen-
erac's success in providing the most reliable generators possible. Generac's G-
Force engine lineup offers added peace of mind and reliability for when it's needed
the most. The G-Farce series engines are purpose built and designed to handle the
rigors of extended run times in high temperatures and extreme operating conditions.
TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave
form produce less than 5% Total Harmonic Distortion for utility quality power. This
allows confident operation of sensitive electronic equipment and micro -chip based
appliances, such as variable speed HVAC systems.
TEST CRITERIA:
✓ PROTOTYPE TESTED ✓ NEMA MG11-22 EVALUATION
✓ SYSTEM TORSIONAL TESTED ✓ MOTOR STARTING ABILITY
O MOBILE LINK® CONNECTIVITY: FREE with select Guardian Series Home standby
generators, Mobile Link Wi-F allows users to monitor generator status from any-
where in the world using a smartphone, tablet, or PC. Easily access information such
as the current operating status and maintenance alerts. Users can connect an
account to an authorized service dealer for fast, friendly, and proactive service. With
Mobile Link, users are taken care of before the next power outage.
GENERACNNEW11111111111111
GUARDIAN° SERIES
Residential Standby Generators
Air -Cooled Gas Engine
Standby Power Rating
G007038-1, G007039-1, G007038-3, G007039-3 (Aluminum - Bisque) - 20 kW 60 Hz
G007042-2, G007043-2, G007042-3, G007043-3 (Aluminum - Bisque) - 22 kW 60 Hz
GENERAC
cONus or CLISTEDUS O I - �
(,J O
Note: CETL or CUL certification only appplies to unbundled units and units packaged
with limited circuit switches. Units packaged with the Smart Switch are En. or UL
certified in the USA only.
O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This
state-of-the-art power maximizing regulation system is standard on all Generac mod-
els. It provides optimized FAST RESPONSE to changing load conditions'and MAXI-
MUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge
loads to the engine. Digital voltage regulation at ±1%.
O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network
provides parts and service know-how for the entire unit, from the engine to the small-
est electronic component.
O GENERAC TRANSFER SWITCHES: Long life and reliability are synonymous with
GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC
product line is offered with its own transfer systems and controls for total system
compatibility.
-IGENERAC n =tea jr-MNn
GENERAC®
20/22 kW Features and Benefits
Engine
• Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly
rings help the engine run cooler, reducing oil consumption and resulting in longer engine life.
• "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life.
• Electronic ignition/spark advance These features combine to assure smooth, quick starting every time.
• Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance, and longer engine
life. Now featuring up to a 2 year/200 hour oil change interval.
• Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil.
• High temperature shutdown Prevents damage due to overheating.
Generator
• Revolving field Allows fora smaller, lightweight unit that operates 25% more efficiently than a revolving armature generator.
• Skewed stator Produces a smooth output waveform for compatibility with electronic equipment.
• Displaced phase excitation Maximizes motor starting capability.
• Automatic voltage regulation Regulating output voltage to ±1 % prevents damaging voltage spikes.
• UL 2200 listed For your safety.
Transfer Switch (if applicable)
• Fully automatic Transfers vital electrical loads to the energized source of power.
• NEMA 313 Can be installed inside or outside for maximum flexibility.
• Remote mounting Mounts near an existing distribution panel for simple, low-cost installation.
Evolution- Controls
•
AUTO/MANUAUOFF illuminated buttons
•
Two-line multilingual LCD display
•
Sealed, raised buttons
•
Utility voltage sensing
•
Generator voltage sensing
•
Utility interrupt delay
• Engine warm-up
• Engine cool -down
• Programmable exercise
• Smart battery charger
• Main line circuit breaker
• Electronic governor
Selects the operating mode and provides easy, at -a -glance status indication in any condition.
Provides homeowners easily visible logs of history, maintenance, and events up to 50 occurrences.
Smooth, weather -resistant user interface for programming and operations.
Constantly monitors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage.
Constantly monitors generator voltage to verify the cleanest power delivered to the home.
Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5
seconds by a qualified dealer.
Verifies engine is ready to assume the load, setpoint approximately 5 seconds.
Allows engine to cool prior to shutdown, setpoint approximately 1 minute.
Operates engine to prevent oil seal drying and damage between power outages by running the generator for
5 minutes every other week. Also offers a selectable setting for weekly or monthly operation providing
flexibility and potentially lower fuel costs to the owner.
Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature.
Compatible with lead acid and AGM -style batteries.
Protects generator from overload.
Maintains constant 60 Hz frequency.
Unit
• SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding
winds up to 150 mph (241 km/h). Hinged key locking roof,panel for security. Lift -out front for easy access .
to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability.
• Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries.
• Small, compact, allractive Makes for an easy, eye appealing installation, as close as 18 in (457 mm) away from a structure.
s
GENERAC®
20/22 kW Features and Benefits
Installation System
• 14 in (35.6 cm) flexible fuel line connector Listed ANSI Z21.75/CSA 6.27 outdoor appliance connector for the required connection to the gas supply
piping.
• Integral sediment trap Meets IFGC and NFPA 54 installation requirements.
Connectivity (Wi-Fi equipped models only)
• Ability to view generator status Monitor generator with a smartphone, tablet, or computer at any time via the Mobile Link application for
complete peace of mind.
• Ability to view generator Exercise/Run and Total Hours Review the generator's complete protection profile for exercise hours and total hours.
• Ability to view generator maintenance information Provides maintenance information for the specific model generator when scheduled maintenance is due.
• Monthly report with previous month's activity Detailed monthly reports provide historical generator information.
• Ability to view generator battery information Built in battery diagnostics displaying current state of the battery.
• Weather information Provides detailed local ambient weather conditions for generator location.
20/22 kW
GENERAC®
Specifications
Generator
Model
G007038-1,G007039-1
G007042-Z G007043-2 G007038-3,G007039-3
G007042-3,G007043-3
(20 kW)
(22 kW) (20 k1N)
(22 kW)
Rated maximum continuous power ppac'nty (LP)-_- . _ - _ _ _
_ 20,000 Watts_`
22,000 Watts'
Rated maximum continuous power capacity (NG)
_
18,000 Watts'
19.500 Wafts " 18,000 Watts`
19,500 Watts `
Ratedd i ltage - -_ - ------------_-
2qp
------ - ._
Rated maximum continuous load current-240 volts (PG)
axi
. ----_-
83.3 / 75.0
- _-8--- - --_-...7,_- -
91.7 / 81.3 83.3 / 75.0
-- - -- -
1Total Harmonic Distortioe ---- -- -_ - -._.- -- --_ _----__---_-
- _ __ _ -._ _-.
--_-__ _Less than5%- --- -^---
--- - ---
---- - - - - -- -- -- - - --- .- _-. - _
Main line circuit breaker
--- --------------
90 amp
------ -- ----- --- -
.. 100- amp 90 amp
- ------ ---
100 amp
(Ptiase - -
Number of rotor poles
- -- - -- - -z --' - - -
- --` ---- -
RaledACfrequency - - - - ----- -- - -- ---- - -- -- -- ---- ----- --
60 Hz
Power factor
1.0
_�?
-
--.-.- -_ - - ____. ----. --._.-_i--_..___ _.-- _ ---_ _.. __ _ __._._.----
Volts, Group 26R 540 CCA m_Inlmum_or_Group 35AGM 650-CCA_minimum
Unit weight (Ib ! kg)
448 / 203
466 / 211 --436 / 198
-445 / 202 -
Dimensions(LxWxH)in
48x25x29/f21.9x63.5x73.7-----
Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load"
67
67 67
67
($oun_d output in dB(A) at 231t (7 m) with generator ln_�uieFTest'"-lbw-speed exercise mode"__
V___
55
_
�_ - ____
57 __
Exercise duration ^- -
__ _ __`
_. _57 _55_ -__- _
5 min
_ -
Engine
Engine type _
LNdmberofcylinders -
Displacement
Cylinder block - -
Valvearrangemenl ---- - -
(lgni5o'nsystem- - --------Y ^- -- -
Govemorsystem
Starter
°-Compression ratio' - -" --"-
[Oticapadt) includingfilter-_-
Operating rpm- - - - -- -
jFuelconsumpt'ion------"- -'--
GENERAC G-Force 1000 Series
999 cc
------ - --- --- - - -_ — --- - - Numfnum w% cast iidn-sleeve_-
Overhead valve -
--------_--_-----_
Electronic - -
9.5:1
12 VDC
Approx 1.9 qt / 1.8 L
Natural gas ft3/hr (m3/hr)
1/2 Load
Full Load
Liquid propane UP/hr (gal/hr) [L/hr]
112 Load
i^ _ 'Full Load
Note: Fuel pipe must be sized for full load. Required fuel p
For BTU content. mullioly ft3/hr x 2500 (LP) or fta/hr x 10001
3,600
i
204 (5.78) 228 (6.46)
164 (4.64)
203 (5.75)
301 (8.52) 327,(9.26)
287 (8.13)
306 (8.66)
87 (237) [8,99] 92 (2.53) [9.57]
86 (2.36)18.951
92 (2.53) [9.57]
130 (3.56) 113.481 142 (3.90) [14.771
136 (3.74) [14.15]
142 (3.90) [14.771
ssure to generator fuel inlet at all load ranges -3.5-7 in water column (0.87-1.74 kPa) tar NG,10-12 in water column
(2.49-2.99 kPa) for LP gas.
G). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG).
Two-line plain text multilingual LCD
Simple user interface for ease of operation.
--- -- - --- ----- --- _ _ - -
Mode buttons: AUTO
--•------------ ---- ----------- ---------- --
Automatic start on utility failure. Weekly, Bi-weekly, or Monthly selectable exerciser. -- a
MANUAL
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
r- -_ - -- -- ------ -- - - -----..----- -- - --
OFF
--- - - - --- --- - --- -- - - - - ---- -- - _
---- - - ----------------_ _-___ --•-.- -- -i
- _ Stops unit Power is removed. Control and charger still operate.-
ini
Ready to RuNMaintenance messages
Standard
- --- -- -- - --- — - - - - --- -- -__ --- - -
� Engine mn hours indication
— -- - - - -
Programmable start delay between 2-1500 seconds
Standard (programmable by dealer only)
L ; ___ _ -"-- - _
LUtility Voltage Loss/Return to Ukhty adjustable (brownout settmg)�
_ __-_._-- ____ _ _
From 140
_
Future Set Capable Exerciser/Exercise Set Error warning - ' --- -'-- _ _
- - - - -- Standard - -
RuNAlarm/Maintenancelogs
50 events each -
Engine start sequence
Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration).
Starter lock-eul - -
Staler cannot re-engage until 5 see after engine has stopped_-
Smart Battery Charger
- -
Standard
_ _.------ -- - ----- - -
�ChargerFangACwar_ning
ult%Missi
_--------- - --
Low Battery/Battery Problem Protection and Battery Condition indication
Standard
_
1Automatic Voltage Regulation with Over and Under Voltage Protection ---
_
- W - - Standard
Under-Frequency/Overload/Stepper Overcurrent Protection
Standard -
�Satety Fused/Euse Problem Protection -
-
- - ~- Standard �' 4- - - -" ,
Automatic Low Oil Pressure/High Oil Tempe--- ra-ture- Shutdown-- - - - --- - - - - -
_ -- - - -- - - - - -- -- -- -- -- - ---- -
Standard
LOver-ceed (@ 72 Hz)/rpm S--e- ---_
-
Standard----------------- -'- _-- - - -- -,
High Engine Temperature Shutdow-nn
Standard
_�
Com--mon externn al fault capability-
_ _------------ —_ -- - -- --- -- - -- �.- _ - - - - - _—_
!Field upgradable firrnvnre
- - - ---- -- - -_ —. -- - —
Standard � - )
"*Sbbntl levels are taken from the front of the generator. Sound levels taken from other sides of the generator maybe
higher depending on installation parameters. listing definitions - Standby: Applicable for supplying
emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). ' Maximum kilovolt amps and current are
subject to and limited by such factors as fuel BTU/megajoule content, ambient temperature, altitude, engine powerand
condition, etc. Maximum power decreases approximately 3.5% for each 1,000 it (304.8 m) above sea
level; and also All decrease approximately 1 % for each 10 IF (6'G) above 60'F (16'C).
_
20/22 kW
Service Rated Smart Switch Features
• Includes digital power management technology (DPM) standard.
• Intelligently manages up to four air conditioner loads with no additional hardware.
• Up to eight additional large (240 VAC) loads can be managed when used in
conjunction with Smart Management Modules (SMMs).
• Electrically operated, mechanically -held contacts for fast, clean connections.
• Rated for all classes of load,100% equipment rated, both inductive and resistive.
• 2-pole,250 VAC contactors.
• Service equipment rated, dual coil design.
• Rated for both aluminum and capper conductors.
• Main contacts are silver plated or silver alloy to resist welding and sticking.
• NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mounting
flexibility.
Dimensions
200 Amps 120/240, iH
Open Transition Service Rated
Height
Width
H1
H2
W1
W2
Depth
in
26.75
30.1
10.5
13.5
6.91
cm
67.95
76.45
26.67
34.29
17.55
Wire Ranges
Conductor Lug
Neutral Lug
Ground Lug
400 MGM - #4
350 MGM - #6
2/0 - #14
GENERAC®
Switch Options
0007039-1 (20 kW)
Model
G007043-2 (22 Mill)
G007039-3 (20 W)
G007043-3 (22 kW)`
2
Current rating (amps)
200
Voltage rating (VAG) ^�
120/240,1fd_
Utility voltage monitor(fixed)`
-Pick-up
80%
-Dropout
65%
LRetum to Utility` _-- —_
Approx.l3 se_c_^_
� Jt
Exercises bi-weekly for 5 minutes*
Standard
�ETL or UL listed �� Tw
_
_ Standard
Enclosure type
NEMA/UL 3R
Circuit breaker protected
_
22,000
_
Lug range
250 MCM - #6
*Function of Evolution controller
Exercise can be set to weekly or monthly
w,
H2 HI
oevm I—
20/22 kW
GENERAC®
Available Accessories
Model # Producty _ Description
G005819-00 26R Wet Cell Battery ^Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery
for use with all air-cooled standby product (excluding PowerPact®).
G007101-0 Battery Pad Warmer Pad warmer rests under the battery. Recommended for use if temperature regularly falls below 0 °F (-18 °C). (Nat
necessary for use with AGM -style batteries).
G907102-0
01 Warmer
' Oil warmer slips directly overthe oil filter. Recommended for used temperature regularly falls below 0 °F (-18 °C).
6007103 1 T
Breather Warmer —�— -�
Breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates'
I
{
LAuxiliary
where heavy icing occurs. p
G000556_21_-0
I
Transfer Switch
Contact Kit
The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load that may not+
be needed. Not compatible with 50 amp pre -wired switches. f!
G007027-0 - Bisque
Fascia Base Wrap Kit
The fascia base wrap snaps together around the bottom of the new air-cooled generators. This offers a sleek, con -
(Standard on 22 kW)
toured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the
base.
G005703-0 - Bisque
Touchp Paint Kit U
If the generator enclosure is scratched or d, lt damageis —important to touch up the paint to protect from future corro
sion. The touch-up paint kit includes the necessary paint to correctly maintain or touch up a generator enclosure.
G006485-0
Scheduled Maintenance Kit
Generac's scheduled maintenance kit provides .all the items necessary to perform complete routine maintenance on a
—
G007005-0
Wi Fi LP Tank Fuel Level
Generac automatic standby generator (oil not included).
The Wi-Fi enabled LP tank fuel level monitor provides constant monitoring of the connected LP fuel tank. Monitoring
Monitor
the LP tanks fuel level is an important step in verifying the generator is ready to run during an unexpected powerfailure.
Status
alerts are available through a free application to notify users when the LP tank is in need of a refill.
6007000-0 (50 amp)
G007006-0 (100
Smart Management Module
Smart Management Modules (SMM)are used to optimize the performance of a standby generator. It manages large
electrical loads upon startup and sheds them to aid in recovery when overloaded. In many cases, using SMM's can
amp)
reduce the overall size and cost of the system.
G007169-0
Mobile Link® Cellular r
The Mobile Link family of Cellular Accessories allows users to monitor generator status from anywhere in the world,
I i
Accessories
using a smart phone, tablet, or PC. Easily access information such as the current operating status and maintenance
alerts. Users can connect an account with an authorized service dealer for fast, friendly, and proactive service. With
Mobile Link, users are taken care of before the next power outage.
Model
UPC
G007038-1
696471074185
G007038-3
696471074185
G007039-1
696471074192
G007039-3
696471074192
G007042-2
696471074208
G007042-3
696471074208
G007043-2
696471074215
G007043-3
696471074215
GENERAC®
n
tz
Dimensions & UPCs
LEFTSIDE VIEW FROM VIEW
Dimensions shown are approximate. See installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLA11ON PURPOSES.
Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com