OFFICE USE ONLY: AUG 2 6 2021
DATE FILED: St.Lucie County PERMIT# 2106-0095
REVISION FEE: •� RECEIPT#
PLANNING&DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DI ;.
2300 VIRGINIA AVENU
_ FORT PIERCE, FL 34982-5 2
(772)462-1553
APPLICATION FOR BUILDING PERMI R IONi ,+
PROJECT INFORMATION
LOCATION/SITE
ADDRESS:
3040 Johnston Road, Fort Pierce, FL 34951
DETAILED DESCRIPTION OF PROJECT
REVISIONS: -
See attached Energy Calcs for Change of Equipment Manufacturer(clouded)
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CGC1520713 ST. LUCIE CO CERT. #:
BUSINESS NAME: RA Construction Corp of the Treasure Coast
QUALIFIERS NAME: Richard A.Adams III
ADDRESS: 850 N. Federal Hwy.,Ste.226
CITY: Stuart STATE: FL ZIP: 34994
PHONE (DAYTIME): 772-446-4576 FAX: 772-446-4514
OWNER/BUILDER INFORMATION:
NAME: Jose A.Vides-Sierra and Lisa K.Vides
ADDRESS:383 SW North Shores Blvd.
CITY: Port Saint Lucie STATE: FL ZIP; 34986
PHONE (DAYTIME: 772-240-6170 FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME: Stanley Forrest
ADDRESS: 5000 Avenue of the Stars
CITY: Kissimmee STATE: FL ZIP: 34746
PHONE(DAYTIME): 407-997-8000 EXT5153 FAX:
SLCCC: 9123109
Revised 06130/17
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index,the more efficient the home.
Lot 2 Johnson Road, Fort Pierce, FL, 34951
1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Polystyrene Bead AggR=0.0 2020.70 ft2
b.Frame-Wood,Adjacent R=11.0 380.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? No 11.Ceiling Type and insulation level Insulation Area a.Roof Deck(Unvented) R=20.0 2672.00 ft2
6. Conditioned floor area(ft2) 2672 b.N/A R= ft2
7. Windows- Description Area c.N/A R= ft2
a. U-Factor: Sgl,U=0.45 368.00 ft2 12.Ducts,location&insulation level R ft2
a.Sup:Attic, Ret:Attic,AH:Garage 6 90
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
SHGC: 13.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 41.5 SEER:16.00
SHGC:
d. U-Factor: N/A ft2 14.Heating systems kBtu/hr Efficiency
SHGC: a. Electric Strip Heat 34.0 COP:1.00
Area Weighted Average Overhang Depth: 10.576 ft.
Area Weighted Average SHGC: 0.250
8. Skylights Description Area 15.Hot water systems
a. U-Factor(AVG): N/A ft2 a.Propane Cap: 1 gallons
EF:0.6
SHGC(AVG): N/A
b. Conservation features
9. Floor Types Insulation Area None
a.Slab-On-Grade Edge Insulation R=0.0 2672.00 ft2 Credits(Performance method) CF,Pstat
b.N/A R= ft2
c.N/A R= ft2
I certify that this home has compli d wit the Florid Energy Efficiency Code for Building E sT
Construction through the above�ener saving fe ures which will be installed (or exceeded) ���TN = ATFo
in this home before final ins cti erwl a new-EPL Display Card will be completed
based on installed Code c lia feature
Builder Signature: Date:
Address of New Home: j�t���� STDI� / 0 City/FL Zip:
s f oo WE ..
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/18/2021 9:22 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Vides Residence Builder Name:
Street: Lot 2 Johnson Road Permit Office: St.Lucie County
City,State,Zip: Fort Pierce,FL,34951 Permit Number:
Owner: Jose&Lisa Vides Jurisdiction: St.Lucie County
Design Location: FL,Fort Pierce County: St.Lucie(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 10. Wall Type�2400.7 sqft.) Insulation Area
2. Single family or multiple family Detached a.Concrete Block-Polystyrene Bead Agg?=0.0 2020.70 ft2
b.Frame-Wood,Adjacent R=11.0 380.00 ft2
3. Number of units,if multiple family 1 c.N/A
R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? No 11.Ceiling Types (2672.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=20.0 2672.00 ft2
6. Conditioned floor area above grade(ft2) 2672 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
7. Windows(368.0 sqft.) Description Area 12.Ducts R ft2
a. U-Factor: Sgl,U=0.45 368.00 ft2 a.Sup:Attic,Ret:Attic,AH:Garage 6 90
SHGC: SHGC=0.25
b. U-Factor: N/A ft2 13.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 41.5 SEER:16.00
c. U-Factor: N/A ft2
SHGC: 14.Heating systems kBtu/hr Efficiency
Area Weighted Average Overhang Depth: 10.576 ft. a.Electric Strip Heat 34.0 COP:1.00
Area Weighted Average SHGC: 0.250
8. Skylights Area
c. U-Factor:(AVG) N/A ft2 15.Hot water systems
SHGC(AVG): N/A a.Propane Tankless Cap: 1 gallons
9. Floor Types (2672.0 sqft.) Insulation Area EF:0.600
a.Slab-On-Grade Edge Insulation R=0.0 2672.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 16.Credits CF,Pstat
Glass/Floor Area: 0.138 Total Proposed Modified Loads: 78.34 PASS
Total Baseline Loads: 79.34 I hereby certify that the plans and specifications covered by Review of the plans and O ZHE ST,q?�
this calculation are in compliance with the Florida Energy specifications covered by this ti ��' ,_ oO,t
Code. calculation indicates compliance �;'%
with the Florida Energy Code.
PREPARED sY: Before construction is completedUJ
`' '' r
DATE: 8-18-202 this building will be inspected for
compliance with Section 553.908 *. ,
I hereby certify that this buil mg, as d _compliance Florida Statutes.
with the Florida Energy Coe C0 III
OWNER/AGENT: BUILDING OFFICIAL:
DATE: 7 --2_4 DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2).
8/18/2021 9:22 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Vides Residence Bedrooms: 3 , Address Type: Street Address
Building Type: User Conditioned Area: , 2672 Lot#
Owner Name: Jose&Lisa Vides Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 0 Street: Lot 2 Johnson Road
Permit Office: St.Lucie County Cross Ventilation: No County: St.Lucie
Jurisdiction: St.Lucie County Whole House Fan: No City,State,Zip: Fort Pierce,
Family Type: Detached FL, 34951
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low
BLOCKS
Number Name Area Volume
1 Entire House 2672 28308
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Bedroom 2 196 1960 No 2 1 1 Yes Yes Yes
2 Bath 2 110 1100 No 0 1 Yes Yes Yes
3 Toilet 2 24 240 No 0 1 No Yes Yes
4 WIC 2 60 600 No 0 1 Yes Yes Yes
5 Pantry 36 360 No 0 1 No Yes Yes
6 Laundry 96 960 No 1 1 Yes Yes Yes
7 Hall 36 360 No 0 1 No Yes Yes
8 Mud Room 48 480 No 1 1 No Yes Yes
9 Family Room 625 7500 No 4 1 Yes Yes Yes
10 Kitchen 299 2990 Yes 2 1 No Yes Yes
11 Safe Room 25 250 No 1 1 No Yes Yes
12 Closet 36 360 No 0 1 No Yes Yes
13 Bath 36 360 No 0 1 No Yes Yes
14 Study 144 1440 No 2 1 Yes Yes Yes
15 Foyer 100 1100 No 0 1 Yes Yes Yes
16 Master Bedroom 238 2618 No 2 1 1 Yes Yes Yes
17 M Bath 140 1400 No 1 1 Yes Yes Yes
18 M Toilet 28 280 No 0 1 Yes Yes Yes
19 M WIC 84 840 No 0 1 Yes Yes Yes
20 Closet 3 36 360 No 0 1 No Yes Yes
21 Bath 3 78 780 No 0 1 Yes Yes Yes
22 Bedroom 3 197 1970 No 1 1 1 Yes Yes Yes
8/18/2021 9:22 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 2 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Bedroom 2 28 ft 196 ft2 ---_ 1 0 0
2 Slab-On-Grade Edge Insulatio Bath 2 9 ft 110 ft2 _-__ 1 0 0
3 Slab-On-Grade Edge Insulatio Toilet 2 1 ft 24 ft2 ---_ 1 0 0
4 Slab-On-Grade Edge Insulatio WIC 2 6 ft 60 ft2 -__- 1 0 0
5 Slab-On-Grade Edge Insulatio Pantry 1 ft 36 ft2 ____ 1 0 0
6 Slab-On-Grade Edge Insulatio Laundry loft 96 ft2 ____ 1 0 0
7 Slab-On-Grade Edge Insulatio Hall 1 1 ft 36 ft2 _-__ 1 0 0
8 Slab-On-Grade Edge Insulatio Mud Room 1 ft 48 ft2 _-_- 1 0 0
9 Slab-On-Grade Edge Insulatio Family Room 25 ft 625 ft2 ____ 1 0 0
10SIab-On-Grade Edge Insulatio Kitchen 1 ft 299 ft2 _--_ 1 0 0
11SIab-On-Grade Edge Insulatio Safe Room 1 ft 25 ft2 __-_ 1 0 0
12SIab-On-Grade Edge Insulatio Closet 1 ft 36 ft2 ____ 1 0 0
13SIab-On-Grade.Edge Insulatio Bath 1 ft 36 ft2 ____ 1 0 0
14SIab-On-Grade Edge Insulatio Study 16 ft 144 ft2 ____ 1 0 0
15SIab-On-Grade Edge Insulatio Foyer 8 ft 100 ft2 ____ 1 0 0
16SIab-On-Grade Edge Insulatio Master Bedroom 31 ft 238 ft2 ____ 1 0 0
17SIab-On-Grade Edge Insulatio M Bath 8 ft 140 ft2 ____ 1 0 0
18Slab-On-Grade Edge Insulatio M Toilet 4 ft 28 ft2 ---- 1 0 0
19SIab-On-Grade Edge Insulatio M WIC 6 ft 84 ft2 ____ 1 0 0
20SIab-On-Grade Edge Insulatio Closet 3 1 ft 36 ft2 ____ 1 0 0
21SIab-On-Grade Edge Insulatio Bath 3 9 ft 78 ft2 ____ 1 0 0
22SIab-On-Grade Edge Insulatio Bedroom 3 33.2 ft 197 ft2 ---_ 1 0 0
ROOF
/ Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Hip Metal 2988 ft2 0 ft2 Light N 0.6 No 0.9 No 20 26.57
/ ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 2672 ft2 N N
8/18/2021 9:22 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Unvented) Bedroom 2 0 Blown 196 ft2 0.1 Wood
2 Under Attic(Unvented) Bath 2 0 Blown 110 ft2 0.1 Wood
3 Under Attic(Unvented) Toilet 2 0 Blown 24 ft2 0.1 Wood
4 Under Attic(Unvented) WIC 2 0 Blown 60 ft2 0.1 Wood
5 Under Attic(Unvented) Pantry 0 Blown 36 ft2 0.1 Wood
6 Under Attic(Unvented) Laundry 0 Blown 96 ftz 0.1 Wood
7 Under Attic(Unvented) Hall 1 0 Blown 36 ft2 0.1 Wood
8 Under Attic(Unvented) Mud Room 0 Blown 48 ft2 0.1 Wood
9 Under Attic(Unvented) Family Room 0 Blown 625 ft2 0.1 Wood
10 Under Attic(Unvented) Kitchen 0 Blown 299 ft2 0.1- Wood
11 Under Attic(Unvented) Safe Room 0 Blown 25 ft2 0.1 Wood
12 Under Attic(Unvented) Closet 0 Blown 36 ft2 0.1 Wood
13 Under Attic(Unvented) Bath 0 Blown 36 ft2 0.1 Wood
14 Under Attic(Unvented) Study 0 Blown 144 ft2 0.1 Wood
15 Under Attic(Unvented) Foyer 0 Blown 100 ft2 0.1 Wood
16 Under Attic(Unvented) Master Bedroom 0 Blown 238 ft2 0.1 Wood
17 Under Attic(Unvented) M Bath 0 Blown 140 ft2 0.1 Wood
18 Under Attic(Unvented) M Toilet 0 Blown 28 ft2 0.1 Wood
19 Under Attic(Unvented) M WIC 0 Blown 84 ft2 0.1 Wood
20 Under Attic(Unvented) Closet 3 0 Blown 36 ft2 0.1 Wood
21 Under Attic(Unvented) Bath 3 0 Blown 78 ft2 0.1 Wood
22 Under Attic(Unvented) Bedroom 3 0 Blown 197 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
R_VaIJJPTn
0
1 N Exterior Concrete Block-Polysty8adroom 2 0 14 0 10 0 140.0 ft2 0 0 0.5 0
2 E Exterior Concrete Block-Polysty& droom 2 14 0 10 0 140.0 ft2 0 0 0.5 0
3 N Exterior Concrete Block-PolystyrerBath 2 9 0 10 0 90.0 ft2 0 0 0.5 0
4 N Exterior Concrete Block-PolystyrerW IC 2 6 0 10 0 60.0 ft2 0 0 0.5 0
_ 5 N Exterior Concrete Block-Polystyrdo3undry 10 0 10 0 100.0 ft2 0 0 0.5 0
6 E Exterior Concrete Block-Polystyrarrmily Room 25 0 12 0 300.0 ft2 0 0 0.5 0
7 S Exterior Concrete Block-PolystyrenStudy 4 0 10 0 40.0 ft2 0 0 0.5 0
_ 8 W Exterior Concrete Block-PolystyrenStudy 12 0 10 0 120.0 ft2 0 0 0.5 0
9 N Exterior Concrete Block-PolystyrerFoyer 1 0 11 0 11.0 ft2 0 0 0.5 0
10 S Exterior Concrete Block-PolystyrerFoyer 1 0 11 0 11.0 ft2 0 0 0.5 0
_11 W Exterior Concrete Block-PolystyrerFoyer 6 0 11 0 66.0 ft2 0 0 0.5 0
_12 E Exterior Concrete Block-PolystpAeeter Bedro 14 0 11 0 154.0 ftZ 0 0 0.5 0
13 S Exterior Concrete Block-PolystVaster Bedro 17 0 11 0 187.0 ft2 0 0 0.5 0
_14 S Exterior Concrete Block-PolystyreM Bath 8 0 10 0 80.0 ft2 0 0 0.5 0
15 S Exterior Concrete Block-PolystyreM Toilet 4 0 10 0 40.0 ft2 0 0 0.5 0
_16 S Exterior Concrete Block-PolystyreM WIC 6 0 10 0 60.0 ft2 0 0 0.5 0
_17 S Exterior Concrete Block-PolystyrerBath 3 9 0 10 0 90.0 ft2 0 0 0.5 0
18 N Exterior Concrete Block-Polysty&edroom 3 4 0 10 0 40.0 ft2 0 0 0.5 0
8/18/2021 9:22 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w
_19 S Exterior Concrete Block-Polystyledroom 3 12 0 10 0 120.0 ft2 0 0 0.5 0
20 SW Exterior Concrete Block-Polysty[Rwdroom 3 3 7 10 0 35.8 ft2 0 0 0.5 0
_21 W Exterior Concrete Block-Polystyirdroom 3 10 0 10 0 100.0 ft2 0 0 0.5 0
_22 NW Exterior Concrete Block-Polysty&sdroom 3 0 3 7 10 0 35.8 ft2 0 0 0.5 0
_23 W Garage Frame-Wood Laundry 11 8 10 80.0 ft2 0.23 0.5 0
24 N Garage Frame-Wood Mud Room 11 4 10 40.0 ft2 0.23 0.5 0
_25 W Garage Frame-Wood Mud Room 11 8 10 80.0 ft2 0.23 0.5 0
26 W Garage Frame-Wood Safe Room 11 5 10 50.0 ft2 0.23 0.5 0
27 N Garage Frame-Wood Closet 11 1 10 10.0 ft2 0.23 0.5 0
28 N Garage Frame-Wood Study 11 12 10 120.0 ft2 0.23 0.5 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 W Insulated Foyer None .39 3 8 24 ft2
2 W Insulated Mud Room None .39 2 8 8 21.3 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 E 2 Vinyl Low-E,Single Yes 0.45 0.25 Y 54.0 ft2 15 ft 0 in 1 ft 4 in None None
2 N 3 Vinyl Low-E Single Yes 0.45 0.25 Y 8.0 ft2 1 ft 5 in 1 ft 4 in None None
3 N 5 Vinyl Low-E Single Yes 0.45 0.25 Y 6.0 ft2 1 ft 5 in 1 ft 4 in None None
4 E 6 Vinyl Low-E Single Yes 0.45 0.25 Y 128.0 ft2 15 ft 0 in 1 ft 4 in None None
5 W 8 Vinyl Low-E Single Yes 0.45 0.25 Y 36.0 ft2 6 ft 0 in 1 ft 4 in None None
6 E 12 Vinyl Low-E Single Yes 0.45 0.25. Y 36.0 ft2 15 ft 0 in 1 ft 4 in None None
7 E 12 Vinyl Low-E Single Yes 0.45 0.25 Y 18.0 ft2 15 ft 0 in 1 ft 4 in None None
8 S 14 Vinyl Low-E Single Yes 0.45 0.25 Y 16.0 ft2 1 ft 5 in 1 ft 4 in None None
9 S 17 Vinyl Low-E Single Yes 0.45 0.25 Y 8.0 ft2 1 ft 5 in 1 ft 4 in None None
10 SW 20 Vinyl Low-E Single Yes 0.45 0.25 Y 11.0 ft2 1 ft 5 in 1 ft 4 in None None
11 W 21 Vinyl Low-E Single Yes 0.45 0.25 Y 36.0 ft2 1 ft 5 in 1 ft 4 in None None
12 NW 22 Vinyl Low-E Single Yes 0.45 0.25 Y 11.0 ft2 1 ft 5 in 1 ft 4 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 609 ft2 609 ft2 38 ft loft 11
8/18/2021 9:22 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software- Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000404 2830.8 155.31 291.57 .1212 6
HEATING SYSTEM
# System Type Subtype Speed Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COP6.1 34 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split Singl SEER:16 41.5 kBtu/hr cfm 0.7 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Propane Tankless Exterior 0.6 1 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cart # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
--Supply--- ---Return--- Air CFM 25 CFM25 HVAC#
v # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 90 ftz Attic 20 ftz Default Leakage Garage (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling [ ]Jan Feb �[]]Mar Apr Ma Jun Jul [ Au Se Oct Nov Dec
Heatin IX}Jan Feb lxl Mar f Apr I May 4 Jun Jul j Au4 SeP f Oct f X}Nov f X�Dec
Venting [ ]Jan Feb [X]Mar [X]Apr May [ Jun Jul [ Aug [ Se [X]Oct [X]Nov [ ]Dec
8/18/2021 9:22 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 6 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Storage
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 1
Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedrrom 3
Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC
Default(8 Ibs/sq.ft. ft2 ft 0.3 Great Room
Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom
Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet
Default(8 Ibs/s .ft. ft2 ft 0.3 Kitchen
8/18/2021 9:22 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 7 of 7
Pro ect Summary Date:
+ - wrightsoft Enure House By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com
Project • •
For: Jose&Lisa Vides, Lot 2 Johnson Road
Fort Pierce, FL 34951
Notes:
Design • •
Weather: Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 °F Outside db 90 of
Inside db 70 °F Inside db 75 °F
Design TD 28 °F Design TD 15 °F
Daily range M
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 28186 Btuh Structure 24415 Btuh
Ducts 5773 Btuh Ducts 3936 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment.load 33959 Btuh Use manufacturer's data n
Rate/swing multiplier 0.95
Infiltration Equipment sensible load 26933 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 6553 Btuh
Ducts 2986 Btuh
Central vent(0 cfm) 0 Btuh
Heatingg Cooling (none)
Area (ft2) 2672 2672 Equipment latent load 9539 Btuh
Volume (ft) 28308 28308
Air changes/hour 0.32 0.16 Equipment Total Load (Sen+Lat) 36472 Btuh
Equiv.AVF (cfm) 151 75 Req.total capaci at 0.70 SHR 3.2 ton
Heating Equipment Summary C oling Eq pmen ummary
Make Make Rheem
Trade Trade RHEEM
Model Cond RA1642AJ1NB
AHRI ref Coil RH1T4821STANJAUSA
AHRI ref 7942888
Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER
Heating input 9.8 kW Sensible cooling 29050 Btuh
Heating output 33279 Btuh Latent cooling 12450 Btuh
Temperature rise 22 °F Total cooling 41500 Btuh
Actual air flow 1383 cfm Actual air flow 1383 cfm
Air flow factor 0.041 cfm/Btuh Air flow factor 0.049 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.75
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft', 2021-Aug-18 09:18:53
<.••..,: RightSuite®Universal 2021 21.0.06 RSU08101 Page 1
�� ...r\Documents\Wrightsoft HVAC\Vides Residence.rup Calc=MJ8 Front Door faces: W
+}+ wrightsoft' Right-J® Worksheet Job:
Entire House Bate`
By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com
1 Room name Entire House Bedroom 2
2 Exposed wall 193.2 ft 28.0 ft
3 Room height 10.6 ft 10.0 ft heat/cool
4 Room dimensions 14.0 x 14.0 ft
5 Room area 2672.0 ft' 196.0 ft'
Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load
number (Btuh/ft'--°F I (Btuh/ft') or perimeter (ft) I (Btuh) I or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 VII 13A-7.5ocs 0.095 n 2.66 1.26 441 427 1136 540 140 140 372 177
1B-rlfv 0.980 n 27.44 21.83 6 0 165 131 0 0 0 0
1B-rlfv 0.980 n 27.44 21.83 8 0 220 175 0 0 0 0
13A-7.5ocs 0.095 a 2.66 1.26 594 358 952 452 140 86 229 109
11 1A-r1ov 0.900 a 25.20 42.33 36 0 907 1524 0 0 0 0
,A-rlov 0.900 a 25.20 19.79 72 72 1814 1425 54 54 1361 1069
1A-rlovd 0.900 a 25.20 19.79 128 128 3226 2533 0 0 _ 0 0
13A-7.5ocs 0.095 s 2.66 1.26 628 604 1607 763 0 0 0 0
-G 1B-rlfv 0.980 s 27.44 21.83 16 16 439 349 0 0 0 0
L-G 1 B-rl fv. 0.980 _ S 27.44'_ 21.83 8 8 220 175 _ _. .0 _..0 .. 0 0
VII 13A-7.5ocs 0.095 sw 2.66 1.26 36 25 67 32 0 0 0 0
G 1A-rlov 0.900 sw 25.20 31.01 11 2 277 341 0 0 0 0
1�213A-7.5ocs 0.095 w 2.66 1.26 286 190 505 240 0 0 0 0
1A-r1ov 0.900 w 25.20 42.33 36 0 907 1524 0 0 0 0
1A-r1ov 0.900 w 25.20 28.50 36 22 907 1026 0 0 0 0
D 11D0 0.390. w 10.92 10.34 24. 24 262 248 0 0 _ _ 0 _. _ 0
V�I 13A-7.5ocs 0.095 nw 2.66 1.26 36 25 67 32 0 0 0 0
G 1A-r1ov 0.900 nw. 25.20 34.05 11 0 277 375 0 0 0 0
C, - 16X19-0md _.. 0.4.08 1.59 1.37 2672 2672 4237 3656 _-196- 196 311 268
F, 22A-tol 0.989 27.69_ _0.00 .2672 193 _ 5349 0 196 28 775 0
61 c)AED excursion 1 322 -120
Envelope loss/gain 1 23540 15861 1 1 3048 1503
12 a) Infiltration 4646 1244 644 172
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 17 3910 2 460
Appliances/other 3400 0
Subtotal(lines 6 to 13) 28186 24415 3692 2135
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 28186 24415 3692 2135
15 Duct loads 20% 16% 5773 3936 20% 16% 756 344
1Aroom loadI I I 3I 283511
I I 444111 247
irreqdn) 1383 1383 1811 12
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Aug-1 8 09:18:53
RightSuite@ Universal2021 21.0.08 RSU08101 Page 1
...rlDocumentslWrightsoft HVAC\Vides Residence.rup Calc=MJ8 Front Door faces: W
-{`� vvrightsoft' Right-JO Worksheet Job:
Entire House Date:
By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com
1 Room name Bath 2 Toilet 2
2 Exposed wall 9.0 ft 0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 1.0 x 110.0 ft 4.0 x 6.0 ft
5 Room area 110.0 ft' 24.0 ft'
Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load
number (etuh/ft2_F I (Btuh/Ft') or perimeter (ft) (Btu I or perimeter (ft) (Btuh)
Heat Cool i Gross I N/P/S j Heat Cool Gross I N/P/S j Heat I Cool
6 13A-7.5ocs 6.095 n 2.66 1.26 90 82 218 104 0 0 0 0
1B-rlfv 0.980 n 27.44 21.83 0 0 0 0 0 0 0 0
1B-r1fv 0.980 n 27.44 21.83 8 0 _ 220 175 0 0 _ 0 0
13A-7.50cs 0.095 a 2.66 1.26 0 0 0 0 0 0 0 0
11 -G 1A-r1ov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0
IA-rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
1A-rlovd 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
13A-7.50cs 0.095 s 2.66 1.26 0 0 0 0 0 0 0 0
1 B-rl fv 0.980 s 27.44 21.83 0 0 0 0 0 0 0 0
1B-rlfv 0.980 s 27.44 _ 21.83 0 0 0 0 0 0 0 0
VI/ 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0
O 1 A-r1 ov 0.900 sw 25.20 31.01 0 0 0 0 0 0 0 0
13A-7.5ocs 0.095 w 2.66 1.26 0 0 0 0 0 0 0 0
1A-r1ov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0
1A-r1ov 0.900 w 25.20 28.50 0 0 0 0 0 0 0 0
D 1100 0.390 w 10.92 10.34 0 0 0 0 0 0 0 0
Vtl 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0
I-C 1A-r1av 0.900 nw 25.20 _ 34.05 0 0 0 0 _ 0 _ 0 _ 0 0
C _ 16X19-0md 0.408 1.59 1.37 110 110 174 150 24 24 38 _ 33
F 22A-tDI .. _ .. 0.989,_.- 27.69 _ 0.00 110 9 249 0 24
0 .. 0 -0
61 c)AED excursion _26 2
Envelope loss/gain 861 403 1 1 38 31
12 a) Infiltration 207 55 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Applianceslother 0 0
Subtotal(lines 6 to 13) 1068 458 38 31
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1068 458 38 31
15 Duct loads 20% 16% 219 74 20% 16% 8 5
Air requi dal room l(c m) I I oad 1252I 526I I I 42 I 32 I
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-fja- 2021-Aug-18 09:18:53
ACGh Ri g htS ui te®Universal 2021 21.0.0 8 RS U0 8101 Page 2
...r\Documents\Wrightsoft HVAC\Vides Residence.rup Calc=MJ8 Front Door faces: W
wrightsoft• Right-J® Worksheet Job:
Entire House Date:
By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com
1 Room name WIC 2 Pantry
2 Exposed wall 6.0 ft 0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 10.0 x 6.0 ft 6.0 x 6.0 ft
5 Room area 60.0 ft' 36.0 ft'
Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load
number (Btuh/ft'-°F I (Btuh/ft') or perimeter (ft) I (Btuh) I or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool
6 Vll 13A-7.5ocs 0.095 n 2.66 1.26 60 60 160 76 0 0 0 0
I�_GG 1B-rlfv 0.980 n 27A4 21.83 0 0 0 0 0 0 0 0
1B-rlfv 0.980 n 27.44 21.83 0 0 0 0 0 0 0 0
13A-7.5ocs 0.095 a 2.66 1.26 0 0 0 0 0 0 0 0
11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0
1A-rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
,A-rlovd 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
13A-7.5ocs 0.095 s 2.66 1.26 0 0 0 0 0 0 0 0
16-rifv 0.980 s 27.44 21.83 0 0 0 0 0 0 0 0
1B-rlfv 0.980 s. 27.44 21.83 _ 0 .0 0 0 0 0 0 0
V)1 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0
t-G 1A-r1ov 0.900 sw 25.20 31.01 0 0 0 0 0 0 _ 0 0
13A-7.50cs 0.095 w 2.66 1.26 0 0 0 0 0 0 0 0
1A-rlov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0
1A-rlov 0.900 w 25.20 28.50 0 0 0 0 0 0 0 0
D 1.1DO _ . 0.390 w. 10.92 10.34 . 0 0 0 0 0_ 0 0 0
Vl/ 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0
C 1A-r1ov 0.900 nw_ 25.20 34.05 0 0 0 0 _ 0 0 0 0
C 16X19-0md 0.408 1.59 1.37 60 60 95 82 36 36 57 _ 49
F 22A-tol_ 0.969. 27.69 _ _,0.00 60 6 166 0 .36 -0 0 _ 0
61 c)AED excursion 1 -10 3
Envelope loss/gain 421 148 57 47
12 a) Infiltration 138 37 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 O 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 559 184 57 47
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 14 12
14 Subtotal 559 184 71 58
15 Duct loads 20% 16% 114 30 20% 16% 15 9
Total room load 673 214 86 68
Air required(cfm) I 27 10 I I 4I 3
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
i - wrlg��t.of't-- 2021-Aug-18 09:18:53
s1CGE\ -•Y----- •- RighlSuite@ Universal 2021 21.0.08 RSU08101 Page 3
r\Documents\Wrightsoft HVAC\Vides Residence.rup Cale=MJ8 Front Door faces: W
wrightsoft' Right-JO Worksheet Job:
Entire House Date:
By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com
1 Room name Laundry Hall 1
2 Exposed wall 10.0 ft 0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 1.0 x 96.0 ft 6.0 x 6.0 ft
5 Room area 96.0 ft' 36.0 ft'
T Construction U-value Or HTM Area ft' Load Area ft' Load
Y number (Btuh1W--°F I (Btuh/ft') or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh)
Heat Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-7.5ocs 0.095 n 2.66 1.M 106 94 250 119 0 0 0 0
1B-rlfv 0.980 n 27.44 21.83 6 0 165 131 0 0 0 0
1B-rlfv 0.980 n 27A4 21.83 0 0 0 0 0 0 0 0
- VL� 13A-7.5ocs 0.095 a 2.66 1.26 0 0 0 0 0 0 0 0
11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0
1A-rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
.1A-rlovd 0.900 a 25.20 19.79 _ _ 0 0 0 0 _ - .0_ 0 0
13A-7.5ocs 0.095 s_ 2.66 1.26 0 0 0 0 0 0 0 0
1 B-rl fv 0.980 s 27.44 21.83 0 0 0 0 0 0 0 0
1B-rlfv _ _. 0.980- s- 27.44 _21.83 _ .. D . 0 .. - .__. _0. 0 0 _ 0 .0 _ . 0
�l 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0
l-G 1A-rlov 0.900 sw 25.20 31.01 0 0 0 0 0 0 0 0
13A-7.5ocs 0.095 w 2.66 1.26 0 0 0 0 0 0 0 0
1A-rtov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0
1A-rtov 0.900 w 25.20 28.50 0 0 0 0 0 0 0 0
ID 11D0 0.390. w_. 10.92 10.34 -0 0 ._.- .0 0 0 __0 _ 0 ..,_ .. 0
Vu 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0
G 1A-rlov 0.900 nw 25.20 34.05 0 0 0 0 0 0 0 0
C _- 16X19-0md
_ _ ._ 0.408- -_ 1.59 ._. 1.37 ___. 96 ---96 152 131 _ „ 36 _ 36 57 .... 49
F._ 22A-tol .-._ 0.989-_- _ 27.69 ... .0.00 .96 10 277 -.0 . .. _.36 0.
61 c)AED excursion -62 1 -3
Envelope loss/gain 844 319 1 1 57 47
12 a) Infiltration 230 62 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 1 230 0 0
Appliances/other 500 0
Subtotal(lines 6 to 13) 1074 111C 57 47
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 14 12 -57 47
14 Subtotal 1088 1122 0 0
15 Duct loads 20% 16% 223 181 20% 16% 0 0
Total room load I I I 1311 1303 I a I 0
Air required(cfm) 53 64 0 0
01
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Aug-18 09:18:53
RightSuite®Universal 2021 21.0.08 RSUD8101 Page4
r\Documents\Wrightsoft HVAC\Vides Residence.rup Calc=MJ8 Front Door faces: W
- + wrightsoft• Right-J® Worksheet Job:
Entire House Date:
By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com
1 Room name Mud Room Family Room
2 Exposed wall 0 ft 25.0 ft
3 Room height 10.0 ft heat/cool 12.0 ft heaticool
4 Room dimensions 8.0 x 6.0 ft 25.0 x 25.0 ft
5 Room area 48.0 fF 625.0 f?
T Construction U-value Or HTM Area ft' Load Area ft' Load
y I I ( ) I ( )
number (BtuhHt'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross I N/P/S Heat Cool Gross NIP/S Heat Cool
6 1N 13A-7.5ocs 0.095 n 2.66 1.26 0 0 0 0 D 0 0 0
1B-rlfv 0.980 n 27.44 21.83 0 0 0 0 0 0 0 0
1B-rlfv _0.980 n- 27.44.- 21.83 0 _- -0 0 - __0 _ 0 - 0 0 0
13A-7.50
cs 0.095 a 2.66 1.26 0 0 0 0 300 172 458 217
11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0
1A-rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
1A-rlovd 0.900 a 25.20 19.79 0 0 0 0 128. 128_ 3226 2533
13A-7.5ocs 0.095 s 2.66 1.26 0 0 0 0 0 0 0 0
1B-rlfv 0.980 s 27.44 21.83 0 0 0 0 0 0 0 0
.1B-rlfv _ 0.980 s 27.44 ._21.83 0 0 0 --0 _ .0 - 0 .0 - .. - 0
V" 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0
1A-rlov 0.900 sw 25.20 31.01 0 0 0 0 0 0 0 0
1A-rlovocs 0.900 w 2.20 1.33 0 0 0 0 0 0 0 0
1A-rlov 0.900 w 25.2D 42.33 0 0 0 0 0 0 0 0
1A-rlov 0.900 w 25.20 28.50 0 0 0 0 0 0 0 0
D 11D0 0.390 w_ 10.92 .10.34 0 0 0 .0 0 0 0 0
V(/ 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0
I- G 1A-rlov 0.900 nw 25.20 34.05 _ 0 0 0 0 0 0 0 0
C 16X19-0md _- 0.408 - 1.59 1.37 48 _ -48 -76 66 625 625 991 _. 855
F _ 22A-tDl_ _ .0.989. -_ 27.69 -, _ 0.00 48 ._ 0 _0 0 625 25 692 0
6 c)AED excursion -16 -298
Envelope loss/gain 76 50 5366 3307
12 a) Infiltration 0 0 690 185
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 1 230 4 920
Appliances/other 0 900
Subtotal(lines 6 to 13) 76 280 6056 5312
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 14 12 0 0
14 Subtotal 90 292 6056 5312
15 Duct loads 20% 16% 19 47 20% 16% 1240 856
Total room load 1L I Air required(c m) I I I 1029
4 317 39 I 7297I 6168 3011
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wr�gletzort 2021-Aug-1809:18:53
Pig hlSuite®Universal 2021 21.0.08RSU08101 Page
...rlDocuments\Wrightsoft HVAC\Vides Residence.rup Calc=MJ8 Front Door faces: W
+�+ wrightsoft' Right-M Worksheet .lob:
Entire House Date:
By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com
1 Room name Kitchen Safe Room
2 Exposed wall 0 ft 0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 23.0 x 13.0 ft 5.0 x 5.0 ft
5 Room area 299.0 fN 25.0 ft'
Ty Construction U-value Or HTM Area (ft') Load Area (ft2) Load
number (Btuh/ft'-F I (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 V1 13A-7.5ocs 0.095 n 2.66 1.26 0 0 0 0 0 0 0 0
I(�--G 1B-rlfv 0.980 n 27.44 21.83 0 0 0 0 0 0 0 0
1B-rlfv 0.980 n_ 27.44 2.1.83 0 0 0 0 0 0 0 0
13A-7.5ocs 0.095 a 2.66 1.26 0 0 0 0 0 0 0 0
1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0
1A-r1ov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
1A-rlovd 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
y 13A-7.5ocs 0.095 s 2.66 1.26 0 0 0 0 0 0 0 0
L2 1B-r1fv 0.980 s 27.44 21'83 0 0 0 0 0 0 0 0
1B-rlfv 0.980 s 27.44 .__21'83 0 0 0 0 0 0 0 0
T13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0
G 1A-r1ov 0.900 sw 25.20 31.01 0 0 0 0 0 0 0 0
13A-7.50cs 0.095 w 2.66 1.26 0 0 0 0 0 0 0 0
,A-rlov 0.900 W 25.20 42.33 0 0 0 0 0 0 0 0
IA-r1ov 0.900 W 25.20 28.50 0 0 0 0 0 0 0 0
TD 1100 0.390 w 10.92 .10.34 _ 0 0 0 0 0 0 0 .- 0
Vt/ 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0
�G 1A-r1ov 0.900 nw_ 25.20 34.05 0 0 0 0 0_ 0 0 0
C 16X19-0md. 0.408 1.59 1.37 299 299 .474 409 25 25 40 34
F 22A-tot 0.989 27.69 , 0.00 _ 299 0 0 0 25 0 0 _ 0
6 c)AED excursion 1
-1 521 1 1 1 -14
Envelope loss/gain 474 257 40 20
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 2 460 1 230
Appliances/other 2000 0
Subtotal(lines 6 to 13) 474 2717 40 250
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 14 12 0 0
14 Subtotal 488 2728 40 250
15 Duct loads 20% 16% 100 440 20% 16% 8 40
1 I Air requi d(c m)load 524 8111 3155 16111 I I 42I 214
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
i wrog��i Cott RightSuiteOUniver� 2021-Aug-18 09:18:5312021 21.0.08RSU08101 Page6
ACC ...r\Documents\Wrightsoft HVAC\Vides Residence.rup Calc=MJ8 Front Door faces: W
- + wrightsoft` Right-J® Worksheet Job:
Entire House Date:
By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772466-6799 Email:quickcalcs@aol.com
1 Room name Closet Bath
2 Exposed wall 0 ft 0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 6.0 x 6.0 ft 6.0 x 6.0 ft
5 Room area 36.0 ft' 36.0 f?
Ty Construction U-value Or HTM Area Load Area (ft') Load
number (Btuh/ft'-F I (Btuh/ft') or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh)
L I
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat cool
6 13A-7.50
cs 0.095 n 2.66 1.26 0 0 0 0 0 0 0 0
1B-rlfv 0.980 n 27.44 21.83 0 0 0 0 0 0 0 0
.1B-rffy 0.980- .n. 27.44.:. _21.83 -0 .0 -0 0.. 0 0 0 --0
13A-7.5ocs 0.095 a 2.66 1.26 0 0 0 0 0 0 0 0
11 -G 1A-r1ov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0
I
_GO ,A
-rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
1A-rlovd 0.900 e- _ 25.20 _ 19.79 0 0 0- _0 0 _ 0 0 0
W 13A-7.5ocs 0.095 s 2.66 1.26 0 0 0 0 0 0 0 0
1B-rlfv 0.980 s 27.44 21.83 0 0 0 0 0 0 0 0
1 B-rtfv 0.980__ s 27.44 21.83 ___ 0._ _ - 0 _ 0 0 0 0 0 0
V)I 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0
t-G 1A-rlov 0.900 sw 25.20 31.01 0 0 0 0 0 0 0 0
13A-7.50cs 0.095 w 2.66 1.26 0 0 0 0 0 0 0 0
1 A-rl ov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0
1A-r1ov 0.900 w 25.20 28.50 0 0 0 0 0 0 0 0
D 11D0 _.0.390 .w. 10.92 .10.34 _ _ ._...0 .._ _ 0 0 _ _0 0 _ . 0 ___ 0 ._.____ 0
yl 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0
t-G 1 A-rl ov 0.900 nw 25.20 34.05 0 0 0 0 0 0 0 0
C, ,._ 16X19-0md. ._ _ 0.408 1.59 1.37 36 36 57 - _ 49 .,. - 36_. .. 36 57 49
F... 22A-tpl._._... _._ _ 0.989...._-._ .. 27.69 0.00 36 0 0 0 36 ._..
61 c)AED excursion 1 -3 -3
Envelope loss/gain 57 47 1 1 57 47
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Applianceslother 0 0
Subtotal(lines 6 to 13) 57 47 57 47
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 57 47 57 47
15 Duct loads 20% 16% 12 a 20% 16% 12 8
Total room load 69 54 69 54
Air required(cfm) I I I 3I 3I I I 3 I 3
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-Ord- 2021-Aug-18 09:18:53
�� - RightSuiteO Universal 2021 21.0.08 RSU08101 Page 7
..rlDocuments\Wdghtsoft HVACWides Residence.rup Calc=MJ8 Front Door faces: W
t+ wrightsoft* Right-J® Worksheet Job:
Entire House Date:
By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com
1 Room name Study Foyer
2 Exposed wall 16.0 ft 8.0 ft
3 Room height 10.0 ft heat/cool 11.0 ft heat/cool
4 Room dimensions 12.0 x 12.0 ft 1.0 x 100.0 ft
5 Room area 144.0 fP 100.0 fN
Ty Construction U-value Or HTM Area (ft'j Load Area (ft') Load
number (BtuhHt2.F (Btuh/ft') I or perimeter (ft) I (Btuh) or perimeter (ft) I (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-7.5ocs '0.095 n 2.66 1.26 0 0 0 0 11 11 29 14
113 rlfv 0.980 n 27.44 21.83 0 0 0 0 0 0 0 0
1130fv 0.980 n 27.44 21.83 _ 0 _- 0 0 0 0 0 _ 0 _- _- 0
13A-7.5ocs 0.095 a 2.66 1.26 0 0 0 0 0 0 0 0
11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0
1A-r1ov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
IA-rlovd 0.900 e _ 25.20 19.79 _ 0 0 0 - 0 0 0 0 0
13A-7.5ocs 0.095 s 2.66 1.26 40 40 106 51 11 11 29 14
1B-rlfv 0.960 s 27.44 21.83 0 0 0 0 0 0 0 0
CGG 1B-r1
fv 0,960 s 27.44 21.83 0._ 0 0 0 0 0 0 0
VI/ 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0
C 1A-r1ov 0.900 sw - 25.20 - 31.01 -_-- 0 - 0 0 0 0 - 0 - 0 0
13A-7.5oos 0.095 w 2.66 1.26 120 84 223 106 66 42 112 53
1A-r1ov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0
1A-r1
ov 0.900 w 25.20 28.50 36 22 907 1026 0 0 0 0
D_1.100_ _.___ ._. _ 0.390 w 10.92 10.34 _ _ _0 0 0 0 ._ 24 .24_ ... 262 . - _. 248
V►I 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0
�G 1A-rlov 0.900 nw 25.20 34.05 0 0 0 0 0 0 0 0
C .. 16X19-0md = 0.408 - _ 1.59 1.37 - 144 144 -228 _197 _. 100---- - 100 _ _ 159 137
F„ 22A-tol_ 0.989 27.69 .__ ..-0.00 _ 144 16 443 0 100 8 222 . _ 0
6 c)AED excursion 680 28
Envelope loss/gain 1908 2060 1 1 812 438
12 a) Infiltration 368 99 202 54
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 2. 460 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 2276 2618 1015 492
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 2276 2618 1015 492
15 Duct loads 20% 16% 466 422 20% 16% 208 79
Total room load I 2742 3040 I 1223I 572
Air required(cfm) 112 148 50 28
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
�}� wrlgl�tt.oT't' 2021-Aug-1809:18:53
"�- - RightSuite®Universal 2021 21.0.08 RSU08101CK Page 8
..rlDocuments\Wrightsoft HVAC1Vides Residence.rup Calc=MJ8 Front Door faces: W
+f+ wrightsoft• Right-J® Worksheet Job:
Entire House Date:
By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com
1 Room name Master Bedroom M Bath
2 Exposed wall 31.0 ft 8.0 ft
3 Room height 11.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 14.0 x 17.0 ft 1.0 x 140.0 ft
5 Room area 238.0 f? 140.0 f?
T Construction U-value Or HTM Area ft' Load Area ft' Load
y number (Btuh/ft2_ I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool
6 13A-7.5ocs 0.095 n 2.66 1.26 0 0 0 0 0 0 0 0
F-( 1 B-rlfv 0.980 n 27.44 21.83 0 0 0 0 0 0 0 0
�C 1B-rlfv 0.980 n 27.44 21.83 0 0 0 0 0 0 0 0
13A-7.50
cs 0.095 a 2.66 1.26 154 100 266 126 0 0 0 0
11 1A-r1ov 0.900 a 25.20 42.33 36 0 907 1524 0 0 0 0
1A-rlov 0.900 a 25.20 19.79 18 18 454 356 0 0 0 0
1A-r1ovd 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
13A-7.5ocs 0.095 s 2.66 1.26 187 187 497 236 80 64 170 81
1 B-rl fv 0.980 s 27.44 21.83 0 0 0 0 16 16 439 349
---CCGG 1B-r1
fv _... 0.980 _ s 27.44. ,_.21.83 0 0 0 0 0 0 0 0
V(/ 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0
G 1A-rlov 0.900 sw 25.20 31.01 0 0 0 0 0 0 0 0
13A-7.5ocs 0.095 w 2.66 1.26 0 0 0 0 0 0 0 0
1A-r1ov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0
IA-rlov 0.900 w 25.20 28.50 0 0 0 0 0 0 0 0
D LIDO _ 0.390- w 10.92 10.34 0 0 0 .0 __ 0 0. .. 0 0
VII 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0
t-G 1A-rlov 0.900 nw 25.20 34.05 0 0 0 0 0 0 _ 0 0
C 16X19-Omd .0.408- - 1.59 1.37 238 238 _ 377 326 140 140 222 192
F 22A-tDI , 0.989 27.69 0.00 238 31 858 0 140 8 222 0
61 c)AED excursion 1 1 -172 -48
Envelope loss/gain 1 3360 2396 1 1 1053 574
12 a) Infiltration 784 210 184 49
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 2 460 1 230
Appliances/other 0 0
Subtotal(lines 6 to 13) 4144 3066 1237 853
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 4144 3066 1237 853
15 Duct loads 20% 16% 849 494 20% 16% 253 138
Air requomdl(adn) I I 4203I 3174I I 14610I 948I
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
- wrlgl�tzoT'r' 2021-Aug-1 8 09:18:53
Rig htSuite®Univerm12021 21.0.08 RSU08101 Page 9
...r0ocumentslWrightsoft HVAC1Vides Residence.rup Calc=MJ8 Front Door faces: W
+ - wrightsott• Right-M) Worksheet Job:
Entire House Date:
By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcalcs@aol.com
1 Room name M Toilet M WIC
2 Exposed wall 4.0 ft 6.0 ft
3 Room height 10.0 ft heat1cool 10.0 R heat/cool
4 Room dimensions 7.0 x 4.0 ft 14.0 x 6.0 ft
5 Room area 28.0 ft' 84.0 ft'
Ty Construction U-value Or HTM Area (It') Load Area (ft') Load
number (Btuh/ft'--°F I (Btuh/ft') or perimeter (it (Stuh) or perimeter (ft) I (Btuh)
Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool
6 13A-7.5ocs 0.695 in 2.66 1.26 0 0 0 0 0 0 0 0
1B-rlfv 0.980 n 27.44 21.83 0 0 0 0 0 0 0 0
1B-rlfv 0.980 n 27.44 21.83 0 0 0 0 0 0 0 0
13A-7.5ocs 0.095 a 2.66 1.26 0 0 0 0 0 0 0 0
11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0
1A-rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
,A-rlovd 0.900 a 25.20 _ 19.79 _ 0 0 0 0 0 0 0 0
13A-7.5acs 0.095 s 2.66 1.26 40 40 106 51 60 60 160 76
1B-rlfv 0.980 s 27.44 21.83 0 0 0 0 0 0 0 0
1B-rlfv 0.980 s 27.44 21.83 0 0 0 0 0 0 0 0
V)/ 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0
O 1A-rlov 0.900 sw 25.20 31.01 _ 0 0 0 0 0 0 0 0
13A-7.50cs 0. w . 1. 0 0 0 0 0 0 0 0
1A-rlov 0.900900 w 255.2020 42.3333 0 0 0 0 0 0 0 0
lA-rlov 0.900 w 25.20 28.50 0 0 0 0 0 0 0 0
D 1.1D0 0.390 w 10.92 10.34 0 0 0 _0 0 _ 0 0 0
Vtl 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0
�C ,A-rlov 0.900 _nw 25.20 34.05 0 0 0 0 0 0 0 0
C 16X19-0md_ 0.408 1.59 1.37 28 28 44 38 84- 84 133 115
F 22A-tDI 0.989 27.69 0.00 28 4 Ill 0 , .84 6 ,- 166 0
61 c)AED excursion -61 1 -12
Envelope loss/gain 1 262 83 1 1 459 179
12 a) Infiltration 92 25 138 37
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Applianceslother 0 0
Subtotal(lines 6 to 13) 354 107 597 216
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 354 107 597 216
15 Duct loads 20% 16% 72 17 20% 16% 122 35
Air require
d(c m) I al room load417 126I I I 719291
252I
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-ffj wrightt.ott, 2021-Aug-1809:18:53
AfE R ightSuite@Universa12021 21.0.08 RSU08101 Page 10
...rlDocumentslWrightsoft HVAC\Vides Residence.rup Calc=MJB Front Door faces: W
- + wrightsoft• Right-J® Worksheet Job:
Entire House Date:
By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:qulckcalcs@aol.com
1 Room name Closet 3 Bath 3
2 Exposed wall 0 ft 9.0 ft
3 Room height 10.0 ft heat/cool 10.0 ft heat/cool
4 Room dimensions 6.0 x 6.0 ft 1.0 x 78.0 ft
5 Room area 36.0 f? 78.0 fN
T Construction U-value Or HTM Area ft' Load Area ft' Load
y number (Btuh/Ft'-°F I (BtuhRN) I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat cool
6 1R! 13A-7.5acs _ 6.095 n 2.66 1.26 0 0 0 6 0 0 0 0
1B-r1fv 0.980 n 27.44 21.83 0 0 0 0 0 0 0 0
1B-rlfv 0.980 n 27.44 21.83 0 0 0 0 '0 0 0 0
. V[� 13A-7.5ocs 0.095 a 2.66 1.26 0 0 0 0 0 0 0 0
11 1A-rlov 0.900 a 25.20 42.33 0 0 0 0 0 0 0 0
1A-rlov 0.900 a 25.20 19.79 0 0 0 0 0 0 0 0
_1A-rlovd- 0.900 _e-_ 25.20 _ 19.79 -_ 0 __. 0 0 0 0_ _ 0 0 0
13A-7.5ocs 0.095 s 2.66 1.26 0 0 0 0 90 B2 218 104
1B-rtfv 0.980 s 27.44 21.83 0 0 0 0 0 0, 0 0
_1B-rtfv 0.980, -a 27.44 __ 21.83 __ .0 0 _ 0 _0 8 8 220 __._ 175
.__
W 13A-7.5ocs 0.095 sw 2.66 1.26 0 0 0 0 0 0 0 0
c _1A-rlov 0.900 sw 25.20 31.01 0 0 0 0 _ 0 0_ 0 0
1A-to ocs 0.900 w 2.20 2.33 0 0 0 0 0 0 0 0
1A-rlov 0.900 w 25.20 42.33 0 0 0 0 0 0 0 0
1A-rlov 0.900 w 25.20 28.50 0 0 0 0 0 0 0 0
D 1.1D0 _, _ 0.390 _w.- _ 10.92 10.34 __ 0 0 .. __ _ 0 .0 0 0 '0 0
Vll 13A-7.5ocs 0.095 nw 2.66 1.26 0 0 0 0 0 0 0 0
G 1A-rlov 0.900 nw 25.20 34.05 0 0 0 0 0 0 0 0
C .-, -16X19-Omd _ _. 6.408. - _ 1.59 1.37 _ 36 .36 _ 57 49 78 78 124 _._ - 107
F_ 22A-tol _..0.989 27.69 0.00 _ 36 0 0 - . .. 7$ -_ _ ..9 .. 249 _ 0
61 c)AED excursion -3 1 -23
Envelope loss/gain 57 47 811 362
12 a) Infiltration 0 0 207 55
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 57 47 1017 417
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 57 47 1017 417
15 Duct loads 20% 16% 12 8 20% 16% 208 67
Air requi dal room load(o m) I I 63 53 I 1250 I 424
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wr�ght 7oYt^��-� =^•'"-- =•^=-•r•�•-�� RightSuite®Universal 2021 21.0.08 RSU08101 2021-Aug-18 09:18:53Page 11
...rlDocumentslWrightsoft HVAC\Vides Residence.rup Calc=MJ8 Front Door faces: W
- +�+ wrightsoft• Right-M Worksheet Job:
Entire House Date:
By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772466-6799 Email:quickcalcs@aol.com
1 Room name Bedroom 3
2 Exposed wall 33.2 ft
3 Room height 10.0 ft heat/cool
4 Room dimensions 1.0 x 197.0 It
5 Room area 197.0 ft'
Ty Construction U-value Or I HTM I Area (ft') I Load Area I Load
number (Btuh/ft'-"F (etuh/ft') or perimeter (ft) (Btuh) or perimeter
Heat Cool Gross N/P/S I Heat Cool Gross N/P/S Heat Cool
6 13A-7.5ocs 0.665 n 2.66 1.26 40 40 106 51
1 B-r1 fv 0.980 n 27.44 21.83 0 0 0 0
1B-r1fv _. _.. _.0.980 .. In, . 27.44 ,_ 21.83 0 0 . ...`. 0 -0
13A-7.5ocs 0.095 a 2.66 1.26 0 0 0 0
11 -G 1 A-rl ov 0.900 a 25.20 42.33 0 0 0 0
1A-rlov 0.900 a 25.20 19.79 0 0 0 0
1A-rlovd 0.900 a 25.20 19.79 0 0 0 , 0
13A-7.5ocs 0.095 s 2.66 1.26 120 120 319 152
1B-rlfv 0.980 s 27.44 21.83 0 0 0 0
1B-rlfv 0.980 s 27.44,:_ 21.83 ._ _ 0 0 0 0
Vi/ 13A-7.5acs 0.095 sw 2.66 1.26 36 25 67 32
� _C 1A-r1ov 0.900 sw 25.20 - 31.01 11 2 277 341
13A-7.5ocs` 0.095 w 2.66 1.26 100 64 170 81
1A-r1ov 0.900 w 25.20 42.33 36 0 907 1524
1A-rlov 0.900 w, 25.20 28.50 0 0 0 0
D 11DO _ 0.390- w 10.92 10.34 ___ ___0 0 0 _0
Vll 13A-7.5ocs 0.095 nw 2.66 1.26 36 25 67 32
G 1A-rlov 0.900 nw 25.20 _ 34.05 11 0 277 375
C 16X19-0md .. __- .0.408 1.59 1.37 _ -_,. 197 _.197 . .. 312 270
F.. . 22A-tol.. _.0.989---- _ 27.69 ,.._.....0.00 _. 197 -- - 33 918 0
61 c)AED excursion 644
Envelope loss/gain 3422 3500
12 a) Infiltration 763 204
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 1 230
Appliances/other 0
Subtotal(lines 6 to 13) 4185 3934
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 4185 3934
15 Duct loads 20% 16% 857 634
Total room load I 50421 4568
Air required(cfm) 2051 223
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-f{+t wrlg��tzof't-' 2021-Aug-18 09:18:53
RightSuite®Universal 2021 21.0.08 RSU08101 Page 12
r\Documents\Wrightsoft HVAC\Vides Residence.rup Calc=MJ8 Front Door faces: W
+I+ wrightsoft
Duct System Summary Da
Job:
House By:
Quick Calcs, Inc.
317 St.Lucie Lane,Fort Pierce,FL 34946 Phone:772-466-6799 Email:quickcaics@aol.com
Project • •
For: Jose&Lisa Vides, Lot 2 Johnson Road
Fort Pierce, FL 34951
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O
Lowest friction rate 0.250 in/100ft 0.250 in/100ft
Actual air flow 1383 cfm 1383 cfm
Total effective length (TEL) 200 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Mat] Ln (ft) Ln (ft) Trunk
Bath h 69 3 3 0.356 4.0 Ox 0 VIFX 25.4 115.0 st3
Bath 2 h 1287 52 26 0.307 5.0 OX 0 VIFX 27.7 135.0 st7
Bath 3 h 1226 50 24 0.251 5.0 Ox 0 VIFx 44.5 155.0 st6
Bedroom 2 h 4448 181 121 0.301 8.0 Ox 0 VIFX 31.3 135.0 st7
Bedroom 3 c 4568 205 223 0.251 8.0 OX 0 VIFX 44.2 155.0 st6
Closet h 69 3 3 0.371 4.0 Ox 0 VIFx 19.8 115.0 st3
Closet 3 h 69 3 3 0.250 4.0 Ox 0 VIFX 45.0 155.0 st6
Family Room c 3084 149 150 0.327 8.0 OX 0 VIFx 37.7 115.0 st1
Family Room-A c 3084 149 150 0.324 8.0 Ox 0 VIFx 39.6 115.0 st1
Foyer h 1223 50 28 0.298 5.0 OX 0 VIFx 32.7 135.0 st5
Kitchen c 3168 24 155 0.338 8.0 OX 0 VIFX 32.9 115.0 st1
Laundry c 1303 53 64 0.392 6.0 OX 0 VIFx 12.7 115.0 st4
M Bath h 1490 61 48 0.313 6.0 OX 0 VIFX 44.7 115.0 st2
M Toilet h 426 17 6 0.306 4.0 Ox 0 VIFX 48.1 115.0 st2
M Wlc h 719 29 12 0.308 4.0 Ox 0 VIFx 47.1 115.0 st2
Master Bedroom h 4993 203 174 0.304 8.0 Ox 0 VIFx 49.4 115.0 st2
Mud Room c 339 4 17 0.366 4.0 Ox 0 VIFX 21.6 115.0 st3
Pantry h 86 4 3 0.372 4.0 Ox 0 VIFX 19.5 115.0 st4
Safe Room c 290 2 14 0.379 4.0 Ox 0 VIFx 17.0 115.0 st3
Study c 3040 112 148 0.297 7.0 Ox 0 VIFx 33.4 135.0 st5
Toilet 2 h 46 2 2 0.297 4.0 OX 0 VIFX 33.5 135.0 st7
WIC 2 h 673 27 10 0.386 4.0 Ox 0 VIFx 14.4 115.0 st4
wrightsoft" 2021-Aug-1809:18:55
RightSuite®Universa12021 21.0.08 IRS U08101 Page 1
P1CC� ...r\Documents\wrightsoft HVAC\Vides Residence.rup calc=MJ8 Front Door faces: W
i
SupplyDetail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (Cfm) FIR (fpm) (in) (in) Material Trunk
st2 Peak AVF 311 240 0.304 570 10.0 0 x 0 VinlFlx
st6 Peak AVF 258 249 0.250 584 9.0 0 x 0 VinIFIX st5
st5 Peak AVF 420 425 0.250 542 12.0 0 x 0 VinlFlx st3
st3 Peak AVF 432 461 0.250 587 12.0 0 x 0 VinlFlx
st1 Peak AVF 321 456 0.324 580 12.0 0 x 0 VinlFlx
st7 Peak AVF 235 149 0.297 533 9.0 0 x 0 VinlFlx st4
st4 Peak AVF 320 226 0.297 586 10.0 0 x 0 VinlFlx
TableReturn Branch Detail
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk
rb1 Ox 0 1383 1383 0 0 0 0 Ox 0 VIFx
wrightsoft" 2021-Aug-18 09:18:55
,{� Rig htSuite®Universal2021 21.0.08 RSU081 01 Page
tCCk ...ADocuments\Wrightsoft HVAC1Vides Residence.rup Calc=MJ8 Front Door faces: W
2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
a
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Vides Residence Builder Name:
Street: Lot 2 Johnson Road Permit Office: St.Lucie County
City,State,Zip: Fort Pierce,FL,34951 Permit Number: Y
U
Owner: Jose&Lisa Vides Jurisdiction: St.Lucie County W
x
Design Location: FL, Fort Pierce U
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall .
Shafts,penetrations Duct shafts, utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac 3s.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
extend behind pip'na and wiring,
Shower/tub The air barrier installed at exterior,walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub-floor,wall covering or
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
F —fi—�--inkler cover plates and walls or cell
a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400.
8/18/2021 9:22 AM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 1 of 1