Certification for Design Load Compliance
Project Name: Smith Residence
Project Address: 6129 Carlton Road
Permit #: occupancy Type: Single Family Construction Type: CBS
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN -PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Residential Code Fifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): 'X Enclosed Partially Enclosed Open
3. Risk Category: _I X II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph ASD X LRFD End Zone'Width: 4 ft
S. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: -53.1 Zone 2: -92•4 Zone 3: -136.6 Zone 4: -62•9 - Zone 5: -77.6 Garage: N/A
7. Design Loads: Floor: 40 PSF Roof/Dead: 25 PSF Roof/Live: /20 Balcony: PSF
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified
William P. Stoddard Ph. D.. P.E. 57605
Signature, Dai,e, and;;Seal
Revised 07/ZSn014 e "
Print Name Cert # & Co. Cert Auth.
Schulke, Blttle & Stoddard, L.L.C.
1717 Indian River Blvd. Suite 20, Vero Beach, FI 32960