Loading...
HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 J Certification for Design Load Compliance Project Name: Smith Residence Project Address: 6129 Carlton Road Permit #: occupancy Type: Single Family Construction Type: CBS INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN -PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Residential Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): 'X Enclosed Partially Enclosed Open 3. Risk Category: _I X II III IV Exposure Category: B X C D 4. Design Wind Velocity 160 mph ASD X LRFD End Zone'Width: 4 ft S. Mean Roof Height 18 ft Roof Pitch: 6 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: -53.1 Zone 2: -92•4 Zone 3: -136.6 Zone 4: -62•9 - Zone 5: -77.6 Garage: N/A 7. Design Loads: Floor: 40 PSF Roof/Dead: 25 PSF Roof/Live: /20 Balcony: PSF Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings: PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified William P. Stoddard Ph. D.. P.E. 57605 Signature, Dai,e, and;;Seal Revised 07/ZSn014­ e " Print Name Cert # & Co. Cert Auth. Schulke, Blttle & Stoddard, L.L.C. 1717 Indian River Blvd. Suite 20, Vero Beach, FI 32960 Company Name & Address