Loading...
HomeMy WebLinkAboutProduct Evaluation ReportBUILDING DROPS A Perfect Solution in Every Dropl Certificate of Authorization: 29578 of 398 East Dania Beach Blvd. Suite 338 Dania Beach, FL 33004 954.399.8478 PH 954.744.4738 FX contact@buildingdrops.com Silver Line Building Products Corp. V1 Series / 70 Series Single -Hung Window (2127) (Impact) (HVHZ) for Florida Product Approval FL# FL14911 res , . Ci <,�r ! :: yMs Current Florida Building Code Method: 1— D (Engineering Evaluation) Category: Windows Sub — Category: Single Hung Product: V1 Series / 70 Series Single Hung Window (2127) Material: PVC Product Dimensions: See Installation Instructions, SWD050 Prepared for: Salver line Building Products Corp. One S1lverilne Dr. North Brunswick, NJ 08902 ````,%1111111111�'' % E 0 Prepared by: E p0 Hermes F. Nore�®,,P.E. _ N .7 7 Florida Professional Engineer # 73778 �'o S A OF• Date:01/23/2018 i 0 �4 Contents: Evaluation Report Pages 1-3 O IDP.' ''i FS e'i� S Digitally signed by Hermes F. Norero, P.E. nomsml, �� E. Reason: i am approving this document Date: 2018.04.19 00:55:47-04'00' Harme�s'fl Florida Florida No. 73778 N BUILDING DROPS A Perfect Solution in Every Dropl Certificate of Authorization: 29578 Manufacturer: Silver Line Building Products Corp. Product Category: Windows Product Sub -Category: Single Hung Compliance Method: State Product Approval Method (1)(d) Product Name: V1 Series / 70 Series Single Hung Window (2127) FL#: FL14911 Date: 01/23/2018 Report No: 5486 Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL # 73778) for Silver Line Building Products Corp. based on Method 1d of the State of Florida Product Approval, Florida Department of Business and Professional Regulation - Florida Building Commission. Limits of Use: Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the Current Florida Building Code. See Installation Instructions SWD050, signed and sealed by Hermes F. Norero, P.E. (FL # 73778) for specific use parameters. 1. This product has been evaluated and is in compliance with the Current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Chapter 16 of the Current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing SWD050 require further engineering analysis by a licensed engineer or registered architect. S. See Installation Instructions SWD050 for size and design pressure limitations. Hermes F. Norero, P.E. Florida No. 73778 Page 2 of 3 r BUILDING DROPS FL#: FL14911 A Perfect Solution in Every Dropl Date: 01/23/2018 Certificate of Authorization: 29578 Report No: 5486 Quality Assurance: The manufacturer has demonstrated compliance of window products in Accordance with the Current Florida Building Code and State Rules for manufacturing under a quality assurance program audited by an approved quality assurance entity through Window and Door Manufacturers Association (FBC Organization #: QUA2515). Performance Standards: The product described herein has.been tested per: Referenced Data: Installation: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06/09/12 t AAMA/WDMA/CSA 101/I.S.2/A440-08 1. Product Testing performed by National Certified Testing Laboratories, Inc. (FBC Organization # TST1589) Report: Dated: NCTL 110-16327-1 08/13/2013 Signed and Sealed by: Harold E. Rupp, FL PE No 15935, Sealed Date 02/06/18 NCTL 110-16327-2 11/05/2013 NCTL110-16327-3 08/13/2013 2. Quality Assurance Window and Door Manufacturers Association (FBC Organization #: QUA2515) 3. Material Certification Miami -Dade County Notice of Acceptance Eastman Chemical Company (Previously Solutia) Saflex (Vanceva Composites) PVB Interlayer 4. PVC profiles meet requirements of WDMA/HallMark WD-61 in accordance with AAMA 303 Refer to Installation Instructions (SWD050) for anchor spacing and more details of the installation requirements. Design Pressure: Refer to Installation Instructions (SWD050) for anchor spacing and more details of the installation requirements. Hermes F. Norero, P.E. Florida No. 73778 Page 3 of 3