HomeMy WebLinkAboutProject Information F* e C ors
REVIEWED FOR
CODE COMPLIANCE
Section A (General Information) ST. LUCIE COU TV
�E16ccg/'[/W
Master Permit No. Process No.
Contractors Name: Lucas Roofing,Inc. License# CCC1326319
Job Address 7403 Georges Road, Fort Pierce, FL 34951
ROOF CATEGORY
XLow Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles
Asphaltic Shingles ❑Metal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE-
❑ New roof ❑ Repair ❑ Maintenance XReroofing ❑Recovering
-ROOF SYSTEM INFORMATION
Low Slope Roof Area(SF) 264 Steep Sloped Roof Area(SF) 2,392 Total(SF) 2,656
Section B(Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets.
E
i
i
253
a
- I
sa {2fl !
xs 12
SAS
-
V s
i
e�
as
do .�
� A a Q 1A pi
P l40J
Y
i
Section C(Low Slope Roof) Surfacing:
Fill in specific roof assembly components and identify Fastener Spacing for Anchor/Base Sheet Attachment:
manufacturer Zone 1':—"oc @ Lap,#Rows ® "oo
(If a component is not used,identify as"NA") Zone 1:r" oc @Lap,#Rows "00
System Manufacturer: CertainTeed Modified Bitumen Zone 2:r" oc @Lap,#Rows °00
Product Approval No.:
FL 17322 R7 Zone 3:—" oc @ Lap,#Rows—@ oe
Number of Fasteners Per Insulation Board:
Design Wind Pressures,From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3:
Zone 1':_Zone 1: 7 Zone 2: Zone 3: c ��rate Components Noted and Details as Applicable:
Max. Design Pressure,from the specific product app oval Woodblocking, Gutter, Edge Termination, Stripping,
system: Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing,Coping, Etc.,
Deck: Indicate: Mean Roof Height, Parapet Height, Height of Base
Type: 4416ed Flashing,Component Material,Material'Thickness, Fastener
JG Type,Fastener Spacing or Submit Manufacturers Details that
Gauge Thickness: / / Comply with RAS 111 and Chapter 16..
Slope:
Anchor/Base Sheet&No.df Ply(s):f-7
Anchor/Base Sheet Fastener/Bonding Material: FT.
Insulation Base Layer:
Base Insultation Size and Thickness: Parapet
Base Insulation Fastener/Bonding Material: Height
Top Insulation Layer:
Top Insulation Size and Thickness: �(� FT.
Top Insulation Fastener/Bonding Material:
Mean
Base Sheet(s)&No.of Ply(s): `��`�s�� �� Roof
Base Sheet Fastener/Bonding Material: Height
Ply Sheet(s)'&No.of Ply(s):
i
Ply Sheet Fastener/Bonding Material:
P Y
UrG i'` I
Top Ply Fastener/Bonding Material:
Section D (Steep Slope Roof System)
Roof System Manufacturer:
Notice of Acceptance Number:
I
l L I. 3ZZ
Minimum Design Wind Pressures,If Applicable(From RAS 127 or Calculations):
.Zone 1: Zone 2e: Zone 2n: Zone 2r: Zone 3e: Zone 3r:
i
Deck Type:
Type Underiayment: `l.�s Qom\ Cyr I
R lope:
12 Insulation:
Fire Barrier: !�tL/ rT
Ridge Vent-ilatio ? FastenerType&Spading:
Adhesive Type:
Type-Cap Sheet
y
Mean'Rool'Height: Roof Covering:
Type&Size Drip
Edge:
L�..��4{� �\mil v►-�,�..U�
i
I