Loading...
HomeMy WebLinkAboutEngineering T.E. 5 C H LIT7" Ffle Copy ENGINEERIN a (`/`���y� �"y�R RfE�VtE August 4, 2021 CODE COMPLIANCE Mr. Douglas McAdam ST. LUCIE COUNTY St. Lucie County � N Building Dept. ®CCV#;7f 2300 Virginia Avenue i Fort Pierce, FL 34982 Subject: Re-Roof Letter—Wright Residence Flat Roof Area Per Attached Sketch 7403 Georges Road Ft. Pierce, FL 34951 Engineer's Project Number: 21FO16 j i Dear Mr:McAdam: ; The above referenced project has an existing roof covering system that will be removed down to the wood deck.The new roof systems will be installed per the following specifications. Proiect Design Parameters • Florida Building Code: Seventh Edition • Height of Building: 10'-0" • Building Occupancy Category: II • Slope of Roof Area: Sloped and Flat/Low • Internal Pressure: Enclosed Sloped • Wind Speed: Ultimate: 160 MPH • Edge Zone: 5.8' • Nominal/Allowable: 124 MPH • Corner: 5.8' x 5.8' • Wind Exposure Category: C • Size of Building(WxL): 59'x58' Roof Material Specifications for the Flat Roof Florida Product Approvals: FL 17322 R7: Atlas Roofing Corporation Underlayment and FL 2533.1 R25 CertainTeed, LLC Modified Bitumen Roof System W-71 The existing flat roof covering and underlayment shall be removed, and the existing wood deck shall be verified to be in sound condition. Any necessary sheathing repairs shall be performed per code with minimum size of sheathing repairs to span three rafters (appr)ximately 48"). The existing deck and any repairs shall be re-nailed per current code requirements. UnderlaymentSystem: 75#base sheet mechanically attached The underlayment system shall be installed over minimum 19/32"thick,APA rated plywood.The base layer shall be one of the following: Glasbase; Flexiglas; Flintlastic Base 20; All 1555 Indian River Blvd.,Suite B-145 i T:772.360.4998 Vero Beach, FL 32960 info@�schlittengineering.com I J1 Mr. Harvey August 4, 2021 EPN: 21FO16 Page 2 Weather/Empire Base; Poly SMS Base; Ultra Poly SMS Base; Yosemite with FlintFast 3 in. Insulation Plates with FlintFast#14; Trufast 3" Metal Insulation Plates with Trufast HD fastened per the schedule below: Effective Area Nominal (ASD)Wind Load Pressure Maximum Pressure per Zone (minimum) +PSF -PSF ;method of IVlanufacturer i 1 100 SF 13.7 27.9 -105.0 PSF i 2 100 SF 13.7 59.8 -105.0 PSF 3 16 SF 25.0 83.3 '-105.0 PSF All areas shall be fastened at 4" on center at 3" lap and 4" on center at four (4) equally spaced, staggered center rows. First Ply Roof Covering System: SBS-SA-H � The first ply shall be Black Diamond Base Sheet with 4" side laps and 6" end laps with end laps diagonally staggered not less than 3' apart. Roof Covering System: SBS-AA, SBS-TA, or APP-TA The bonded roof cover shall be one of the following specifications,all three are approved for this use. The contractor shall pick only one for the entire area unless approved by the manufacturer. 1. SBS-AA: Flintlastic FR Cap 30, Flintlastic FR Dual Cap, Flintlastic FR-P, Flintlastic Premium FR-P, Flintastic GMS or any of these products in Coolstar type in hot asphalt at 20-40 Ibs/square. 2. SBS-TA: Flintlastic FR Cap 30,Flintlastic GTS-FR or either of these products in Coolstar type as Torch-Applied. 3. APP-TA: Flintlastic STA, Flintlastic STA Plus, Flintlastic GTA, Flintlastic GTA Coolstar, Flintlastic GTA-FR, Flintlastic GTA-FR Coolstar as Torch-Applied. Roof Material Specifications for the Sloped Roof FL 17322-R7 Atlas Roofing WeatherMaster Underlayment, FL 16305-R10 Atlas Shingles Follow manufacturers product application requirements for additional installation requirements. I have reviewed the above information and certify that to my best knowledge and belief; the referenced method of attachment provides adequate resistance to the wind loads and forces specified by current code provisions.Should you have any questions regarding the above subject, please call. i 1555 Indian River Blvd.,Suite B-145 T:772.360.4998 Vero Beach, FL 32960 info@schlittengineering.com Mr. Harvey August 4, 2021 EPN: 21FO16 Page 3 Very truly yours, ��\� c s��,�s No. 81238 Terence Schlitt, P.E. STATE of FL P.E. #81238 August 4, 2021�%°`` '•,pCpR�pP••' TS/ms Ill I II 111\ cc: Mr. Paul Lucas, Lucas Roofing, Inc. i I f I I i I 1555 Indian River Blvd.,Suite B-145 T.772.360.4998 Vero Beach, FL 32960 info@schlittengineering.com I __ ___ k 3,.,; ' „'�„ 1�- , iy `� \\\ r \ !' _ I `j• 'I I d , .- � .'.1 '�� x :.+ 't.: �` �; .. ' ' .' ��� .. 1 >�; ,;; � ,� .' '� ._. .. _, .'.. j ;. 4 ; .� �, �i r �� jI � '--_ - —• - 4 ._ -� "_ .; ,� ';.i ,,, l � ,i `..� r.� u � 4? 1 '1 ,•�� �J 1.J ; i i 7.^�� ... -- � ,i. <ry � it 1.... ,1 ''1 `i� i �.. .. ,.. � 1 .. -,I .. ,.., =I ��,I ' j _ i _i � -