HomeMy WebLinkAboutROFFING PERMIT INFORMATION SHEETST. LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Required Sections of
the Permit Application
Form
Attachments Required
See List Below
Low Slope Application
A, B, C
1,2,3,4,5,6,7
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
1,2,4,5,6,7
Concrete or Clay Tile
A, B, D, E
1,2,3,4,5.6,7.
Metal Roofs
A, B, D
1,2,3,4,5,6.7
Wood Shingles and
Shakes
A, B, D
IA4,5,6,7
Other
As Applicable
1,2,3,4,5.6,7
ATTACHMENTS REQUIRED As Applicable):
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3,
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7,
Any Required Roof Testing/Calculation Documentation
Form Rooflnfofeb2l Rev Feb 18, 2021
ST. LUCIE WORKS
Master Permit No.
Contractors Name:
DOUG LEMAN
Section A (General Information)
Job Address 2001 N 44th ST FORT PIERCE FL 34947
Q'Low Slope
❑Asphaltic Shingles
❑ New roof ❑ Repair
Low Slope Roof Area (SF) 200
Process No.
License # CCC1329687
ROOF CATEGORY
❑ Mechanically Fastened Tile
Metal Panel/Shingles
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ Mortar/Adhesive Set Tiles
❑Wood Shingles/Shakes
❑ Maintenance VReroofing
ROOF SYSTEM INFORMATION
Steep Sloped Roof Area (SF) 1600
❑ Recovering
Total (SF) 1800
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
ST. LUIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(if a component is not used, identify as "NA")
System Manufacturer: POLYGLASS Product Approval No.: T L�- I L-.�Li —` p
—Z3
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1'�-) Zone 1: Ljl� Zone 2-13 ) Zone 3: �35
Max. Design Pressure, from the specific product approval
system:
Deck:
Type; 1 q
Gauge Thickness:
Slope:
z"
Anchor/Base Sheet & No. df Ply(s):'�
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer: NONE
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer: NONE
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s): 21
Base Sheet Fastener/Bonding Material:
POLYGLASS SAV SELF ADHERING
Ply Sheet(s)' & No. of Ply(s): 1
Ply Sheet Fastener/Bonding Material:
SELF ADHERING
Top Ply: POLY GLASS SAP
Top Ply Fastener/Bonding Material:
SELF ADHERING
Surfacing:
Fastener Spacing for Anchor/Base Sheet
ment:
Zone 1':
oc @ La , # Rows "00
Zone 1:—"
oc @ L , #Rows00
Zone 2:—"
oc @ L , # Row ° or
Zone 3:—"
o s
oc @ ar # Roy
Number of Fastenkrs Per Insulati
Zone 1': Zone 1: Zone 2: Zone 3:
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc..
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
ST. LUCIE
Section D (Steep Slope Roof System)
Roof System Manufacturer: ATLANTIC METAL II
Notice of Acceptance Number:
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1: Zone 2e: Zone 2n: Zane 2r: Zone 3e: Zone 3r:
Deck Type: PLYWOOD
Type Underlayment., KIRSCH SHARKSKIN ULTRA SA
Roof Slope:
3 • �2
Insulation: NONE
Fire Barrier: NONE
Ridge Ventilation? Fastener Type & Spacing: t Z" p U 112 r3 vo P L
Adhesive Type: NONE
Type Cap Sheet NONE'
Mean Roof Height: Roof Covering: 5V 24 GA GALVALUME
Type & Size Drip Z 7c Z
Edge: