Loading...
HomeMy WebLinkAboutROFFING PERMIT INFORMATION SHEETST. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5.6,7. Metal Roofs A, B, D 1,2,3,4,5,6.7 Wood Shingles and Shakes A, B, D IA4,5,6,7 Other As Applicable 1,2,3,4,5.6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3, Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7, Any Required Roof Testing/Calculation Documentation Form Rooflnfofeb2l Rev Feb 18, 2021 ST. LUCIE WORKS Master Permit No. Contractors Name: DOUG LEMAN Section A (General Information) Job Address 2001 N 44th ST FORT PIERCE FL 34947 Q'Low Slope ❑Asphaltic Shingles ❑ New roof ❑ Repair Low Slope Roof Area (SF) 200 Process No. License # CCC1329687 ROOF CATEGORY ❑ Mechanically Fastened Tile Metal Panel/Shingles ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ Mortar/Adhesive Set Tiles ❑Wood Shingles/Shakes ❑ Maintenance VReroofing ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) 1600 ❑ Recovering Total (SF) 1800 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ST. LUIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (if a component is not used, identify as "NA") System Manufacturer: POLYGLASS Product Approval No.: T L�- I L-.�Li —` p —Z3 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1'�-) Zone 1: Ljl� Zone 2-13 ) Zone 3: �35 Max. Design Pressure, from the specific product approval system: Deck: Type; 1 q Gauge Thickness: Slope: z" Anchor/Base Sheet & No. df Ply(s):'� Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: NONE Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: NONE Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): 21 Base Sheet Fastener/Bonding Material: POLYGLASS SAV SELF ADHERING Ply Sheet(s)' & No. of Ply(s): 1 Ply Sheet Fastener/Bonding Material: SELF ADHERING Top Ply: POLY GLASS SAP Top Ply Fastener/Bonding Material: SELF ADHERING Surfacing: Fastener Spacing for Anchor/Base Sheet ment: Zone 1': oc @ La , # Rows "00 Zone 1:—" oc @ L , #Rows00 Zone 2:—" oc @ L , # Row ° or Zone 3:—" o s oc @ ar # Roy Number of Fastenkrs Per Insulati Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc.. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. ST. LUCIE Section D (Steep Slope Roof System) Roof System Manufacturer: ATLANTIC METAL II Notice of Acceptance Number: Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: Zone 2e: Zone 2n: Zane 2r: Zone 3e: Zone 3r: Deck Type: PLYWOOD Type Underlayment., KIRSCH SHARKSKIN ULTRA SA Roof Slope: 3 • �2 Insulation: NONE Fire Barrier: NONE Ridge Ventilation? Fastener Type & Spacing: t Z" p U 112 r3 vo P L Adhesive Type: NONE Type Cap Sheet NONE' Mean Roof Height: Roof Covering: 5V 24 GA GALVALUME Type & Size Drip Z 7c Z Edge: