HomeMy WebLinkAboutBuilding PlansMETAL ROOF PANELS OVER PEEL&STICK UNDERLAYMENT OVER Climatic & Geographic Design Criteria Project Data Building Data ' 19/32" CDX PLYWOOD Weathering: Negligible Termite Area: Very Heavy Project Name: Krueger residence Occupancy Type: Group R (3 Ridge SEE CONNECTOR SCHEDULE Flame Spread Index & Smoke Developed Index Street Address: T.B.Di Construction Type: V { „� 12 City: Ft. Pierce Number of Stories: One n Flame Spread: Not to exceed 25 PRE ENG. WD. ]nsulatioCount St. Lucie Project Area: 1, TRUSSES 24"c.c. VERIES Y j 230 s.f. U) Mean R30 GATT INSUL• Insulation Smoke Developed Index: Not to exceed 450 State: Florida p F n N r - � 11'-T GALV. DRIP EDGE ON Building Code j. L. W � TTT Roof Wall Finishes: Not greater than 200 1 x2P.T.ON2x.6 g Z M FASCIA Ceiling Finishes: Not greater than 200 Scope Of Work V 2020 Florida Building Code: Reside t al L � New one level Frame single 2017 National Electric Code NFPA 70 `t Y family residence f. . — Lu00 o 1 (2) 2 x 6 TOP PLATE { . (D d ^ J ❑ CEMENT PANEL SOFFIT WITH SP6 AT EACH STUD WITH 8' x 18" SCREEN WITH(6) 1Od NAILS Design Loads Area Tabulation -� li r VENTS 8'-0"o•p. 1'-6„ _ ._ Q .. Roof Live Load: 20.0 p.s.f. Living 990 F- 2 x 6 STUDS 16"o.c. Floor Live Load: 40.0 ps.f. Porch 240 Z a Wind Speed: 150 MPH >N` LU 0 Wind Importance Factor: 1.0 Total 1230 F.F.E. Building Category: II 0.00' R79 BATT INSULATION J Wind Exposure: C N p CEMENT SIDING Cubic Volume 91 46 C.f. � LU M Internal Pressure Coed en :.18 t c t EXTERIOR FINISH Structure Designed: inclosed � ao Soil bearing capacity: 2000 p.s.f. ONE LAYER OF HOUSE V J WRAP OVER PLYWOOD N 5/8`"CDX PLYWOOD Q) > FASTEN TO STUDS Q PER NAILING SCH'DL. FASTEN SILL WITH 5/8"x 8 0_ U '- WEDGE BOLTS WITH r 1/8" x 3"WASHERS 24"o.c. 3 0 IJJ �I N 3 8 1„ � C 9„ 8-2„ FE] 2 x 6 P.T.SILL PLATE ~ 0 (U WITH SP6 AT EACH STUD 3'-0" 2'-0"' p tC WITH (6) 10d NAILS C.) O Z N W WOOD B ASE FIFE GRADE MIN. 'v Ic" - Po ¢. 00 25 s.h. 25 s.h. HB ', T 4"" 3000# FIBERMIX-CONC. Egress Egress cv .. OVER .006 VAPOR BARRIER ON CLEAN, COMPACTED - TERMITE TREATED FILL 15' 2" (2H ader2 f 1 2868 10'-2" 0 Pocket 1 V-6" MONO, FOOTING 12"x 24-NonH32 Cing. WITH (2) #5 REBAR 1 Functional Louver Bedroom m Safety y a S Typical W��I_ Section. 3/12 Cing. "�- Safety ,h,xy� Linen _ - -. ' Class.. -1 z'4 Frlete _ ." - ( Load Cab. an 4Tem8" aM wall r Bands o a I Walto l r. Load METAL ROOF PANELS OVER U I w PEEL & STICK UNDERLAYMENT OVER 19/32i" CDX PLYWOOD -- SEE CONNECTOR 6' 6"" 4'-6"" 3'-4" Craft Ro01Y1; 25 s.h. SCHEDULE I 8'-1-Cing. Egress 2868 Load 2868 PRE ENG. WD. 12 A.C. Cord. Pocket w l Pocket CementPanal'Siding TRUSSES_ 24'c.c. 2.6� onconc. pad - -- O with 1 x 3 vertical trim Open at 12' o.c. GALV. DRIP EDGE ON I x4Trim at I x2P.T.ON2x6 z Comers, Windows, FASCIA and Doors M (2) 2 x 12 U (2) 2x 12 25 s.h. Header 2668 Header Egress L, r--� (D Pocket � IT-6" W 22""x 36"` i in a t ' 5, 5„ 1,_�- 5,_10„0o U n Access 8_1„ I -� Tankless M Z L _ O Clnl B'_1 "" Water Htr. uJ �. 3068 STUCCO CLNG. Cing. Pocket 5068 Q Se HB ar (2) 2 x 12 BEAM WITH 1 /2" PLYWD. FLITCH BETWEEN d ti I rOPt�I w/d w` CEMENT PANEL SOFFIT H 1 NAI - ih I SinkJl ❑ W a) Left Elevation FASTEN PLYS WIT 6d LS WITH 8" x 18"' SCREEN scale: 1 /4"" = V-0"' VENTS 8'-0"o.c. 1 -6"" 6" o.c. WRAP WITH SIDING Y Wm g m O r o tHB a GreaRoom bbN o Kitchen of +J E E M w 3/12 Cing. l!� 1 V 0 _, y 8'-1_Cing. Ref. O mE��� 4 x 4 P.T. POST a"-o 9 ih Ceiling Ridge WRAP WITH SIDING X r E cv cv I Range & FASTEN BEAM TO COLUMN Exh. Hood Q Vent (� WITH (2) MSTA18 WITH (14) 10d 1 18'-11" 2'-0 3'-0', 5'-1 " 0 Thru PER STRAP w Wall l o I Beam 1-d.w' l d --_J Pocket e. U I - - date .revision'.. - - - Soffit to Top 00 25 25 25 23 of Window II II PI n R r'w COa ev e scll.h. s.h, s.h. 7/28/21 co s.h. I I �� Elev. Targets ❑❑ � II IV,) ABU44 POST BASE WITH (1) Porch REVIE4VED FOR r. 5/8""x 6"" WEDGE BOLT & (12) o j I 8'-0""Cing. 1sd To POST � CODE MPLIAN ❑ ❑ I I from F.F.E. �y drawn FFE I I ST. LU 1E COUNTY'a.i. e II GRADE d II CD chocked ❑ ❑ I v -- —------- ------ a M LL-----------�-- ------ —�---------_ZC_---------1_I M ,date 4' 3000# FIBERMIX CONC. 3/29/21 OVER .006 VAPOR BARRIER scale ON CLEAN, COMPACTED • TERMITE TREATED FILL sa noted Front Elevation " Job number 3 5'-4'" 2'-2"' 1'-11" 4,_1„ 1,_6„ 2,_6„ 5-0 2'-T" 4'-11 3 20057 scale: 1/4" V-0" SEE FOOTING Floor an ,.DETAILS .Weer FlPlan scale: 1 /4„ V-0" A-1, Porch Detail FILE COPY , x 0 PLUMBING NOTES: Plumber to consult with contractor and equipment ordered for rough in dimensions. 2" v.t.r. 2" v.t.r. Verify all dimensions with the floor plan. The floor plan 2" Lay. dimensions dictates all other dimensions on other sheets. LAV 2".v.t.r. Do not scale drawings, if any conflicts arise, contact the Architect or Engineer for clarification prior to construction. W.C. W.C. All sanitary lines 2" or less shall have a slope of 1 /4"r per sink foot minimum. 2"" v.t.r. I 3 Washer 3"" Shower I 2", 2 All sanitary lines above 2" shall have a slope of 1/8' per 3" foot minimum. , Sink . Provide Anti -Scalding Valve in all showers. Lowest living area floor elevation (refered as 0.00') to be 3", 2," set by a professional land surveyor to the required building 4" department elevation, but not less than 18"" above the crown ° ° of the road. 4," 2", Plumbingcontractor to provide a is septic P system water hammer &shut off valve at each fixture Insulate all hot water lines Plumbing Riser Diagram 4' 9 Typ. O.H. 00 r - - - - - - - - - - - �� 3E 12N1 3R 3R I�2N 3E� -2E�1 3E' 6/12 6/12 2.5 /12 I 2E I I I 11 1 1 1 I 1 2R 2R I I 2N 2N 2N 6/12 -I---- - - - - I" 3R 'v 2R 1 3R I I 3R v 2R 3R 6/126/12 I - 2I - - - - - - 1- "i I 1 I 2N I 'I I I � 1 II' 2.5 /12 I 2N 2N -I - - - - - - -� I- L------------� F3E 2E I3E Roof Plan Roof Wind Zones scale: 1/8" = V-0- scale: 1/8" = 1'-0" PRODUCT APPROVAL Approval Product Model Number Manufacturer Glass Attachment Method Building Rated Product ated Number Type Design Pressures Design Pr ssures Head: 12" max.: from corners & 30"o.c. max. Jambs: FL 239.2 S.H. Windows SH-5500 Singlehung PGT Industries Impact 12" max. from comers & 17.7" max. 5" each side of meeting g rail. #12 wood screw with 1 3/8" embed. +33.5 -44.8 +/- 50.t1 I Head: 2" max. from comers & (1) at center. Jambs: FL# 17499.9 S.H. Windows 185 SH MI Windows Impact 2" max. from corners & (2) equal spaced at each side of meeting rail. Use #10 wood screw with 1 1/4" embed. + 33.5 -44.8 +/- 55.Q Glazed 6" from comers and 3"& 7"each side of center at head & FL#: 17184.2 Swing Doors Fiberglass Plastpro Impact sill and 6-from comers & 14 1 /4"max. o.c. at jambs. +33.5 -36.3 +/-150.0 Door 1/4" wood screws with 1 1/4" embed. Fiberglass Plastpro Impact 6" from corners & 14"o.c. at jambs. head sill. 1/4" wood. : + 65.0 -70.0 Onswing) FL#: 17184.5 Swing Doors Door with 1 1/4" bed. screws wembed. +33.5 -36.3 +/- 85.0 (Ot�tswing) Approval Product Model Number Manufacturer Attachment Method Building Rated Product listed Number Design .Pressures Design ,Pressures FL: 17443.1 Roofing#9-15 5V Crimp JA Taylor Roofing z 1" 000rosion resistant screw with sealing washer at each rib 12"o.c. in field and 6"o.c,along perimeter. -35.0 -69:25 FL: 9777.7 Roofing Underiayment Weatherlock Specialty Owens Comin g Direct attachment to plywood deck -35.0 -142. Fasten with ring shank nails with .090 shank, .215 Head, 1.5"long, FL#: 13192.2 Siding Panel Siding James Hardie 6"o.c. along edges and field. -35.0 -37.0 FORMWORK & SHORING GENERAL FOUNDATION NOTES No structural concrete shall be stripped until it has reached at least 80% of - Concrete shall be a minimum of 4" thick over clean, compacted, the 28 day design strength. termite treated fill and 6 mil polyethylene vapor barrier. Design, Erection, & Removal of all formwork, shores, & reshores shall meet If concrete slab contains 6- x 6" 10/10 WWM provide 1- coverage meet the ACI Standards 347 and 301 Concrete shall have at minimum compressive strength of not less Contractor to verify all building setbacks prior to the start of construction. than 3,000 p.s.i. A formboard survey shall be submitted to the building department for All 90% hooks are to be extended 10- minimum beyond the turn. approval prior to pouring concrete. Field bends are to be done cold and the diameter of the bend, measured on the inside of the bar, is not to be less than six SOIL STATEMENT: bar diameters. Foundation has been designed for a soil bearing capacity of 2000 p.s.i. Minimum coverage for rebar shall be 3" in footings and 1 1/2" in Fill shall be laid in layers of 6-. Each layer to be compacted to 95% bond beams. Hooks may be rotated horizonitally if required to compaction. achieveminimum coverages. If the contractor encounters, while digging the foundation, any Reber overlap shall be 48 bar diameters. 30- for #5 rebar discrepancy to suggest the soil may be inadecuate, he must immediately report it to the owner and the Architect or Engineer The foundation design assumes that the soil has a minimum so as to order a soil boring test. load carrying capacity of 2000 ps.f. In the event the soil bearing capacity falls below 2000 p.s.f. This foundation plan may be superceded by Foundation Design Engineer. Satisfactory compaction test of fill does not verify lower soils are adequate. All specifications and dimensions to be verified by contractor. All exterior slabs shall slope a minimum 1/8- per foot for drainage Wind Zones - Walls F-1 F-2 18" x 18" mono. footing 18" z 16" mono. footing with (2) #5 rebar cont. with (2) #5 rebar cont. 18- 4„ 4„ 8- 18- 18- MONO. EDGE FOOTING INTERIOR STEP FOOTING F-3 F-4 18- x 12- mono. footing Recess 4" at Shower 6" with (2) #5 rebar cont. L'J 4" 8- Rebar 18" 18- INTERIOR FOOTING TYP. SHOWER RECESS 1 6- 4„ 2500# conc. pad ?i SIN co �4 F-1 F-1 _4"" - - - - - - - - - - -I r-- - - - --� IF-31 I I F4 F.-3 IF-31 (I I (------- F-3 l- 250a# 07 15'-10" 14'-2 1 M F-11 IF-1 4" 3000# FIBERMIX CONC. OVER .006 VAPOR BARRIER ON CLEAN, COMPACTED, TERMITE TREATED FILL ASSUMED F.F.E. 0.00' L 3"" I I I 15'-101,, 3,_3"" 10'-10 „ ( 3„ EVIEWED FI ------------ ----------J DECOMPLY F-2 F-2 S '1lN LUCIE COU BOCC F-1I o IF-1 II - - - - - - - - - - - - - - - F-1 1 t=ILE 1 30'-6"" Foundation & Footing Plan scale: 1/4" = V-0" V I ewe a 0 co co !LR_ V Lu14, Z M U_ ho .N W Q 00 N a Q J n •� Q N n v H N V CU Z a UUJ° .. iE N W C 0 > v W 4-) ca > CU U Q r W a) cV OO ca VN Z N C") r drawn s.l. checked s.l. date 3/29/21 scale as noted job number 20057 sheet A-2 Flood Light Flood - Light Electrical Plan scale: 1/4" = V-0" ELECTRICAL LEDGEND -- lQ RECESSED LIGHT WITH LENS ® EXTERIOR & WET LOCATIONS 1 SURFACE MOUNTED LIGHT FIXTURE TT—e SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE UNDER CABINET FLUORESCENT FIXTURE 0 RECESSED INCANDESCENT LIGHT FIXTURE WITH EXHAUST FAN CEILING FAN WITH LIGHT OPTION COMBO. 0 CARBON MONOXIDE O EXHAUST FAN OUTLET SMOKE DETECTOR O MOTION SENSOR bTHERMOSTAT ON SWITCH DUPLEX OUTLET - SWITCHED ® DOOR CHIMES =Cr DUPLEX OUTLET SMOKE DETECTOR M@k 220 V OUTLET -(fi SWITCH -I'r TELEVISION 2 y 4 hottnm cord hracinv Flood Light Bottom Cord Lateral Bracing Meter 8'-1 "" t-- — 1/2- gyp. Septic Hook Up w_ ❑ ❑ -Flood Light F.F.E. pre engineered /trusses 24" o.c. i co 1 -p 1/2"" drywall 6 O (2) 2 x 4 plate with SP4 with (6) 10d x 1 1/2- at each stud 1 /2- gyp. d.w. 2 x 4 studs 16"o.c. O 1 O O 2 x 4 p.t. plate O O' with SP4 with (6) 10d x 1 1/2" at each stud 'Wood base see footing details 5/8" dia. wedge bolt (3) #4/0 (THW) copper NOTINC with 3"" x 1/8 washer 7" embedment 24"o.c. and (1) #2.round (THW) wau ON THIS OERMIT copper in 2 galy. conduit S7�gt4.�interior Brng. Wall Detail Panel: 150 A.M.C.B. Ad 1,6, 3W 40 Circuit 150 Amp Pa.d 120/240 Volt Panel Electrical Load Calculations a.c.disc. /0 (THW) cop er 990 Living S.F. at 3 VA 2970 watts U #2 kround ( HW) One 20 Amp Appliance Ckts. 1500 watts r m 2 gale. c nduit Two Laund Cir @ 1500 watts 3000 watts THREE WAY SWITCH �.. TELEPHONE -1vw One Range Top 8000 watts DIMMER svnTGH o PUSH BUTTON One Dishwasher & One Disposal @ 1500 watts each 3000 watts 5/8" dia. x 10'-0" One Microwave @ 2000 watts 2000 watts NOTE: RECEPTACLES IN KITCHEN & BATH AREAS TO BE 46- A.F.F. long ground rod � 3/4"" copper F.P.L. service One Dryer @ 5 kw 5000 watts water pipe ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING OUTLETS THAT ARE NOT GFGI MUST BE AFCL TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS OWNER TO CORRDINATE LOCATIONS OF TELEPHONES AND TELEVISIONS IN FIELD WITH CONTRACTOR Smoke detectors wired to 120V Bathroom lights Non Switchable,Non .GFI. Electrical contractor to verify all equipment loads prior to start of construction. Electrical contractor to recalculate electrical schedule if loads are to be modified Electrical Notes 1. All loads to be checked by a Florida Licensed Electrician 2. All work to meet the National Electrical Code 3. Calculations and panels below are for sizing conduit and overall building load requirements only 4. All conductors to be copper; all insulation to be THHN. Conduit as follows: PVC below ground, Rigid from underground to service box for exterior lights on building; AC, MC, or EMT conduit elsewhere. 5. Ensure min. 36" clear between equipment and disconnects, Typical Two Ref. @ 1500 watts I WU watts Two Baths @ 1500 watts each 3000 watts Septic Hook Up 1500 watts Water Heater 8000 watts Total 39,470 watts First 10 KVA at 100°% 10,000 watts 81-0" Remainder at 40% 11,788 watts tie ground wire to footing rebar� Total 21,788 watts One AC Heat at 100% 10,000 watts Electrical Riser Diagram Total 31,788 watts 31,788 W / 240 V 132.5 Amps Use 150A Service 30-00-00 Roof Framing Plan scale: 1/4" = V-0" Hatch Legend NAME • e1 ; Connector Schedule Truss Bearing Truss Connector Qnty. Connector Fasteners Point Uplift ID Uplift All trusses to Frame ALL 769 Max. MTS18 1 1000# (14) 10d x 1 1/2" Valley Supporting Framing (4) l Od Trusses <250# VTCR 1 370# Vail Trussey (3) 10d x t 1/2" , 1 vgEv%' a I� .00E C IVIPLI NC T, LUCIE CO Nr Truss Bearing Point Locations are numbered per the Truss Profile 13OCC Sheets Provided by the Truss Manufacturer. Connector Notes: Do not substitute connectors Do not sheath trusses before all straps are in place Attach valley trusses and piggy back trusses, if present,' to main trusses per truss manufacturer drawing. Truss to truss connection by truss company, installed per manufacturers specs. Lateral forces perpendicular and parallel to wall has been considered (less than 300 p.l.f.) Contractor to approve temporary bracing to prevent toppling of trusses, see HIB-9. Other specs, if different from above, have priority. Attic Vents Calculation Attic Area: 1230 s.f. / 150 = 8.2 s.f. re uired. soffit area = 51.5 I.f. x 1.RLE 13 0PY Venting Provided: 8 x 18 soffit vent: 85 sq. in. each vent 15 Vents along overhang = 1,275 sq. irl. 1,275 sq. in. / 144 = 9.4 s.f. l'' Total Ventilation Provided: 8.8 sq. ft. V C CL fn N cr 1. Lu �i Z M v LL O bJDfn ' qj co . � Q LO 0c) N a '' l� J62 Q r ~ V Z aEF VLu 0 o> J uJ C3 '(I) V ) cu `� L /. CU V Q W LO I- N r =oz N LU �cu Q 00 L.L C7 T O Lu U Lu W -C O V, N C� drawn S.I. checked s,. date 3/29/21 scale as noted job number 20057 sheet A-3 Ceramic Tile STRUCTURALNOTES: Bottom Cord Shall be installed in accordance with ANSI A108.1, A108A A108.5 All reinforcing steel shall be high strength billet steel and shall of Truss A108.6, A108.11, Al 18.1, Al 18.3, A136.1, & A137.1. Fiber mat reinforced conform to ASTM A-615 grade 60 specifications. Lap continuous reinforcing 48 bar diameters or 30" in beams and in slabs. Lap backer shall be used behind wall applied ceramic tiles in the tub bottom steel over supports and top steel at midspan. Hook�— and shower areas and conform to ASTM C1325. Per Durock, discontinuous ends of all top bars. Reinforcing steel shall have cement board exceeds ASTM C1325. a minimum of 1" concrete cover, or as follows: BOTTOM TOP SIDES G Gypsum Note 2 x a top plats Beams: 11/2"' 11/2"" 11/2"" Gypsum board shall conform to ASTM C22, C475, C514, 01002, C1047 Slab on Grade: 1 1/2"" 1" _ 01177, 01178, 01278, C1396, or C1658 and installed per FBC residential Structural Poured: 3/4" 3/4" _ Poured Walls: 3/4"" code. Per USG, Wallboard conforms to C1396. _ _ Slabs exposed to the weather 3/4" 1"' Gypsum Board & Gypsum Panel Products _ Reinforcing steel shall be detailed and fabricated in accordance Gypsum board and gypsum panel products shall be applied with the "Manual of Standard Practice of Detailing Reinforcing ""ACI 1/2" gyp. d.w. at right angles or parallel to framing members. All edges and Concrete Structures" and the current Building Code 318"" ends of gypsum board and gypsum panel products shall occur on framing members, except those edges and ends that All structural steel shall conform to current ASTM Specification A-36 2 x 4 studs 24"o.c. are perpendicular to the framing members. Interior gypsum board shall not be installed where it is directly exposed to All wood in contact with masonry shall be pressure treated or approved No. 3 Stud Grade weather or to water, w separating material All dimensions shall be verified in field by the contractor. If there are Wall and ceiling gypsum board shall be fastened with screws any discrepancies the Architect or Engineer shall be notified before spaced at 12"o,c. Screws for attaching gypsum board and gypsum proceeding. 2 x 4 p.t. sill plate panel products to wood framing shall be Type W or Type S in accordance with ASTM C1002 andshall penetrate thewood not less than 5/8" inch (15.9mm) Gypsum board and Gypsum panel All Design and Construction shall be inaccordance with the current wood base products shall be attached to cold formed steel framing less American Concrete Institute (ACI). and the American Institute of Steel than 0.033" 0 mm) thick shall be Type S in accordance with Construction (AISC), The Florida Building Code and all applicable ASTM C1002 or bugle head style in accordance with ASTM C1513 g local codes. Cased Hard Coil and shall penetrate the steel not less than 3/8 " to 0.112" (1 mm to 3mm) thick shall be in accordance with ASTM C954 or Structural Concrete shall attain a minimum ultimate compressive strength Nails 12"o.c. max. bugle head style in accordance with ASTM 1513. Screws for (Fc') in 28 days as follows: attaching gypsum board or gypsum panel products to structural Column Footing andWallFooting: 3000 p.s.i. OA0' —F.F.E. insulated panles shall penetrate the wood structural panle facing All other concrete: ` 3000 p.s.i. not less than 7/16'"o.c. (11.1mm). Footing sizes and reinforcing are based on allowable soil bearing Gypsum board used as the base orbacker for adhesive application capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this Concrete of ceramic tile or other required nonabsorbent finish material shall is not the case, the Architect or Engineer shall be notified before Foundation conform to ASTM 01396, C1178, C1278. Use of water resistant proceeding with the work: gypsum backing board shall be permitted on ceilings. Water Interior Wall Section resistant gypsum board shall not be installed over a Class I or Class 2 vapor retarder in a shower or tub compartment. Out or Timber (Heavy Timber Construction) exposed edges, including those at wall intersections, shall be (a) Truss manufacturer shall submit signed and sealed shop sealed as recommended by the manufactuer. Water resistant drawings by a registered Engineer. (2) 2 4 gypsum backing board shall not be used where there will be (b) Wood rafters to have a Stress Grade of Fb=1200 p.s.i. x direct exposure to water, or areas subject to continuous high (c) Roof members should be secured to the beams or other 70P PLATE humidity. structural components with hurricane anchors for wind uplift. SP4 AT EVERY STUD WITH (6) 10d NAILS Vc.c. All wood members shall have a minimum fiber stress in bendingSP4 (6) 10d TOP &SILL PLATE NAILS Cold Formed Steel Note of 1200 p.s.i. with 1/360 max. deflection. Cold formed steel framing supporting gypsum board and gypsum All bolted connections shall be 1/2"" Cadmium plated or better. (2) MSTA18 04) 10d NAILS panel products shall be not less than 1 1/4" (32mm) wide in the Lag bolts to be used only. in shear connections with minimum least dimension. Non Load bearing cold formed steel framing 4" threaded penetration past steel plate. shall comply with AISI S220 and ASTM C645, Section 10. Load bearing cold formed steel framing shall comply with AISI S200 Lag bolted conditions shall be drill tapped no larger than the and ASTM C955, Section 8. internal thread diameter and shall not be hammer driven. Under Girder Trusses provide equal number of studs as girder (2) I2 x 12�jEADER Wood Framing Note plys at frame bearing locations BOND TOGETHER WITH 16d A(( T 6"c.c. 2 2 x 4 STUDS Wood framing supporting gypsum board and gypsum panel products shall be not less than 2- (51 mm) nominal thickness in th least dimension except that wood furring strips not less than 1" by 2" (25mm x 51mm) nominal dimension shall be GENERAL REQUIREMENTS permitted to be used over solid backing or framing spaced not more than 24"o.c. (610mm) All work to be as per the current edition of the Florida Building Code and meet or exceed all applicable local requirements. 2 x 4 P.T. PLATE EXTERIOR CEILING General contractor is responsible for all labor, materials, utilities, testing, waste removal, storage, securing of site, accomodation, transport/freight, 7/8" Stucco finish over 3/8" high ribbed galy, wire lath fastened to and all other cost related to the completion of this project., unless explicitly framing members with No. 11 guage nails with 1 3/4" embed. with 3/8" identified here. =4 dia. head 6"o.c. max. edges to be tied and nailed at 9"o.c. Install one layer of 15# felt to framing prior to installing ribbed lath Owner is responsible for all municipal relatedcharges such as impact B rn g. Header Detail fees, and water connection, except building permit fees, which are to be INTERIOR WALL FRAMING NOTE included in the construction bid Interior non bearing walls to be 2 x 4 studs 24"o.c. General contractor to check all drawings for errors and ommissions and Spruce, Pine, Fir (SPF) #3 Grade lumber or better bring them to the attention of the architect prior to starting any work, or or metal studs (25 Ga.) Crimper may be used in ordering any materials; of the respective division of work. If such errors lieu of screws. and ommissions are not reported in writingto the architect, any resulting i damages or costs shall be born entirely by the general contractor. THRESHOLD NOTE Architect is not responsible for the contractors method or means of construction. At egress door (see floor plan) the max. hgth. General contractor is to keep the site in a clean and safe state through of the threshold shall be 1 /2" out the course of construction. On building turnover, general contractor to clean all surfaces so as to be free of dust, grease, stains, scuffs, etc. GENERAL ROOFING NOTES Unless otherwise noted, the installation of specified hardware shall conform to the manufacturers instructions and standard practice. Roofing to be composed of and attached to pre manufactured wood trusses as follows: All plans and drawings are not considered complete until they have been reviewed and approved by the St. Lucie County Building Department Felt underlayment (min. ASTM 0 226 Type 11) with 4" min. side and and the building permit has been issued. end laps, fasten with coorosion resistant annular ring shank nails at 6""o.c. in laps and in staggered rows spaced 12"o.c. in field. If roof pitch is < 4/12 install (2) layers 15# felt. If roof pitch is 4/12 or greater, install (1) layer 30# felt. /+ SHEATHING '.NAILING NOTES 'ES 19/32" c.d.x. sheathing or equal installed with staggered joints nailed to trusses with 8d corrosion resistant annular ring shank nails Nailing Pattern Nailing Schedule Ili spaced max. 6"o.c. throughout, except max. 4' o.c. at gable ends. All roof trusses are to be pre -manufactured assemblies provided by Zone 1: 8d at 6 "o.c. field & 4"o.c. edges ROOF & FLOOR DIAGRAM Zone 2E & 2R: 8d at 4-o.c. edges & field Use sheathing with #8 gun nails at 6"o.c. a licensed wood truss fabricator with seperate drawings and data prepared for actual project conditions by a Florida registered Zone 3E & 3R 8d at 4"o.q edges &field at supported panel edges and #8 gun professional engineer certified for truss design. Any deviation from di i t 6" nails ao.c. at intermediate supports. ! ! the proposed plans as shown regarding placement or bearing shall Pneumatic Nails be brought to the attention of the truss engineer prior to fabrication of the trusses. The truss manufacturers certified layout shall govern ROOF SHEATHING TO GABLE END FRAME Pneumatic or mechanicaly driven nails will after fabrication. be accepted under the following conditions: Use #8 gun nails at 4"o.c.. The handling, erection, and fixing of wood trusses shall be in accordance with the specifications contained on the certified mfgr's. Min. nails size 8d or larger ring shank with EXTERIOR SHEATHING Min. shank diameter; .113 drawings and data Min. Length: 2- Use #8 gun nails at 4"o.c, at panel edges Min. Head Diameter:.280 Full Round and #8 gun nails at 4"o.c. at panel top and All engineered headers and truss hangers to be provided by the Min. Ring Diameter .012 over shank dia. bottom and 6-o.c. in field truss manufacturer. Min. 16 to 20 Rings per Inch Splitting or cracking of structural components due to installation of Note hardware is not permitted. Gun nails shall be permitted as an Unless otherwise noted, the installation of specified hardware shall acceptable fastener from any manufacturer conform to the truss manufacturers installation instructions and standard practice. Wood screws meeting the same size requirement may be used in lieu of nails without comment 2) 2 x 6 top plate with 'Simpson" SP6 o stud (6) 10d x 1 1 /2" 1) "Simpson" MSTA18 with (14) 10d each at tud to header 2) 2 x 12 with 1/2' Plywood flitched Deader x 6 p.t sill plate th "Simpson SPH6 each stud with 0) 10d x 1 1 /2" 5/8' dia. wedge bolts with 3" square x 1 /8" washers Door Framin SP6 at each stud and 16"o.c. max. along (2) 2 x 12 header header. Use (6) 10d with 1 /2" plywood 1 1 /2" long for each flitch bond together fastener with 16d Co.c. (2) 2 x 6 staggered top plate Header to Stud with (1) MSTA18 with (14) 10d (1) 2 x 6 under header and (1) 2 x 6 along side of header, bond together with 16d 6""o.c. WINDOW ROUGH 2 x 6 with SPH6 OPENING at stud with (10) / \ / 10d x 1 1 /2" SPH6 at each stud Use (10) 10d X 1 1/2" t6" 2 x 6 p.t. sill plate max. fasten as per typ. wall section Window Framing Detail STEP 1 Apply Horizontal Peel & Stick Fashing over Door Frame. Extend flashing Wood Frame back full width of framing wall i m r� Door Frame Secured to wood framing as per manufacturers recomen- dations TYVEK Building Wrap at wood frame locations STEP 2 Apply Vertical Peel & Stick Fashing over Doo�/ Frame. Extend flashing back full width of framing Concrete Foundation Provide Sealant 6r, Under Threshold JP Frame Wall Door Flashing STEP 3 Apply Horizontal Peel & Stick Fashing over Wood Frame Flange. Extend flashing Wall back full width of framing od Frame Wall Window Flange Secured to wood framing as per manufacturers recomen- dations Wood Fra Wall TYVEK Building Wrap at wood frame locations STEP 2 Apply Vertical Peel & Stick Fashing over Flange. Extend flashing back full widthof framing m 1kc, 1 L6_ STEP Wood Frame Wall Apply Sill Peel & Stick Fashing over Flange. U Ci :3 O `0 00 L. V W Z M M LL C 4t b.0 CD W 0 L. a) 00 N a r) U _a � v cu Z a U W o J0 to W W C 4-0 0 Extend flashing back full width of framing Frame Wall Window Flashing ° �a)n W �J LU Q) 2 x 4 diagonal "X" bracing at ridge with (3) 12d each r 9 endue I Max. 2 x 4 blocking at 4'-0"o.c. starting from ridge between both top and bottom cords (2) 12d trusses 24"o.c for two truss spaces from see layout gable end: See truss shop drawings Continuous 2 x 4 Lateral bracing at 1/3 points of span. Nail with (2) 16d each truss btm. cord Continuous 2 x 4 bracing nailed to top plates with 16d at 12""o.c.' Gable End Bracing Detail — Z W L LU _` (� W Alumin.l WEW min. D FOR '_^^ V, CODE CO PLIANCE cn L. LUCIE OUNTY n B07C 2 x 6 fascia Vented soffit Gable end truss by truss mfgr. date revision 5/8" c.d.x. plywood with 8d nails 4"o.c. FJLE COPY 2x "L" web stiffener as required by the truss mfgr. draw„ "Simpson" MSTA18 truss checked to top plate or alined S.I. stud with 04) 10d x 1 1/2" date located at each truss 3/29/21 _ vertical scale as noted (2) 2 x 6 top plate job number with "Simpson SP6 to stud (6) 10d x 1 1/2"" 20057 sneer A-4 METAL ROOF PANELS OVER PEEL & STICK UNDERLAYMENT OVER Climatic & Geographic Design Criteria Project Data Building Data 19/32" CDX PLYWOOD m- Weathering. Negligible Termite Area: Very Heavy SEE CONNECTOR Project Name: Krueger residence Occupancy Type: Group R SCHEDULE . Flame Spread Index & Smoke Developed Index Street Address: T.B.D. Construction Type: V 12 City: Ft. Pierce Number of Stories: One PRE ENG. WD. Insulation Flame Spread: Not to exceed 25 TRUSSES 24"c.c. VERIES County: St. Lucie �' R30 BATT INSUL Prgiect Area: 1,230 s.f. : Insulation Smoke Developed Index: Not to exceed 450 State' Florida :3 v) cu GALV. DRIP EDGE ON 1 x 2 P.T. ON 2 x 6 Wall Finishes: Not greater than 200 Building Code 0 u! FASCIA q Ceiling Finishes: Not greater than 200 Scope of Work 0 z cn 2Q20 Florida Building Code: Residential � � � 1/2 New one level Frame single 2017 National Electric Code NFPA 70 d D.W. family residence W LU (2) 2 x 6 TOP PLATE Y Q� r-) Q ❑ WITH SP6 AT EACH STUD _ CEMENT PANEL SOFFIT WITH (6)10dHAILS Design Loads AreaTabulation WITH 8"" x 18" SCREEN V-6" g _ Lt VENTS 8'-0"o.c, Qy Roof Live Load: 20.0 p.s.f. 2x 6 STUDSI6"o.c, Floor Live Load: 40.0 ps.f. Living 990 � � 4 45 Wind Speed: 150 MPH Porch 240 z CL Wind Importance Factor. 1.0 (,� ul Iv Ats Barr INSULATION 1230suLATtoN Building Category: II � � ct CEMENT SIDING Wind Exposure: C v1 L Cubic Volume XXXX c.f. Lu CD p EXTERIOR FINISH Internal Pressure Coefficent: :18 Q) M Rear Elevation ', Structure Designed: Enclosed �' scale:1/4" V-0„ Soil bearing capacity: 2000 p.s.f. ONE LAYER OF HOUSE C%) WRAP OVER PLYWOOD 5/8-CDX PLYWOOD CD FASTEN TO STUDS - -_ PER NAILING SCH DL FASTEN SILL WITH 5/8- DIA. VIEDGE BOLTS WITH 30' 0"' 1,3"" Co try x 3" WASHERS 24'o.c. 8'-113-s" w E "I" S_ cv El2 x 6 P.T.SILL PLATE Q Ca I WITH SP6 AT EACH STUD 3'-0" 2'-0" �_ r 17fFH (6) lOd NAILS Z N Open WOOD BASE FFE LIJ r C/) r GRADECO i 25 s.h. 25 s.h. a C'�) _ 4" 3000g FD3ERMIX CONC. Egress Egress N HB ,- N 'OVER .006 VAPOR BARRIER ON CLEAN, COMPACTED. _.--_- -- TERMITE TREATED FILL O Header 1 12868 p 15' 2 Pocket 10._2--------------- 0 \3'-O"/ Right Elevation MOh10.-FODING I is co V-6 scale: 1 /4" = V-Q"" 12"x 24"Non WITH (,2) #5 REBAR Oln,; Functional Louver Bedroom m Cln I H32 s.h. 3/12 Oing. Safety 1 x 4 Frieze Typical Wall, Section Unen Teap.eaoisr. Glass m Bands wdia ca on as^ran wan load V ems. V METAL ROOF PANELS OVER well PEEL & STICK UNDERLAYME'NT OVER p 19/32" CDX PLYWOOd"` Ib ON rp SEE CONNECTOR 6 8 I 3 U_ Craft ROOM r $� 25 s.h. SCHEDULE \ 8'-1 "Cing. Egress 12 2868 soad r 286 I I 1 I I I I I PRE ENG WD. A.G: Cond. Pocket wain S z� rr Cement Panel Siding TRUSSES Wec. 2.5 on cone. pad with 1 x 3 vertical trim Open O at 12"o.c. GALV. DRIP EDGE ON 1 x4Trim at 1x2P.T.ON2x6 a Comers, Windows, FASCIA 4 and Doors M (2) 2 x 12 Header (� rftyj.J, -- 0 2 1 26 D ea Pocke 4 '-6" 25 s.h. Egress L LL la 5- 1'-7„ 5'-10" 2 I 22"x 36' I Access L-_ �+,� i i xto Cing. L-8,_1- o LL1 of Z 6k Tankless Water Htr. STUCCO CLNG. oc et Cing. 508$ LU HB ` BEAM WITH 1/2" PLYWD 2FLrTCH BETWEEN °m 1� j rOpt,1 ~ CEMENT PANEL SOFFIT c �, I�SinkJl w/d W ,II Left, .Elevation FASTEN PLYS WITH 16d NAILS d - WCfH 8" x 18'" SCREEN +� d � o 1'-6 Cox. WRAP WITH SIDING a + _ water scale: 1 /4" = 1._0., VENTS 8'-0' o.c. - oQ. u10. ¢ H I �° O e r HB o E c a 3/12GI OOm o I tCilen " O N E m-M,- M I 8 1"Cing. Ref. mEv�y I F- .. —mot —.. — 4x 4 P.T. POST Q �t v m Ceiling dge WRAP WITH SIDING Ri4 { lyC�oX I x r 1Z( (�IGtC^ FASTEN BEAM TO COLUMN t? m `! ; (p)(�o y'1 IvX w Y') N j ExhgHood t� b Vent WITRI (?) MSTA78 WITH (14) 10d i eo 3 a R 18'-11" 2_0 3 I O Thru PER ST17AP b' Wall A EVIE WED' FOR o CODE COMPLIANCE � Beam ST. LUCIE COUNTY 1 d_w• 1 Pocket —�Occ . a Soffit Top date revision of Window 1 1 25 25 25 23 1 s.h. s.h, s.h. Co m s.h. II ❑ ❑ II ro II ■ ❑ 11 {I ABU44 POST BASE WITH (1) I I Porch 11 56d T 6" WEDGE BOLT & (12) { I l { 16d TO POST � Il 8'-0"Cing. I I I I from F.F.E. 100 d FFE II drawn FFE GRADE chocked ____.— _ _----- — -- -- �y data ---------r��=_ _ , - _�----__�---�-- ____-_ FILE COPY 4" 3000# FIBERMIX CONC. � aizeizl OVER .006 VAPOR BARRIER scale -0N CLEAN. COMPACTED. TERMITE TREATED FILL as notes 3 5'-4" 4'-1" V-6" 2'-6" 5'o" 2'-7 3" job number 2W57 SEE FOOTING sheet DETAILS Floor Plan Porch Detail scale: 1/4" = V-0" A-1