HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Krueger Residence
Builder Name:.
Street: 10900 Heil Road
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL, 34945
Permit Number:
Owner: Kristine Krueger
Jurisdiction: St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1020.5 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Frame - Wood, Exterior
R=19.0 1020.50 ftz
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 1
d. N/A
R= ftZ
5. Is this a worst case? No
11. Ceiling Types (990.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 990.00 ftz
6. Conditioned floor area above grade (ftz) 990
b. N/A
R= ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
7. Windows(116.8 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ftz
6 65
a. U-Factor: Sgl, U=0.28 116.75 ftz
SHGC: SHGC=0.22
b. U-Factor: N/A ftz
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
24.0 SEER:16.00
c. U-Factor: N/A ftz
- SHGC:
Area Weighted Average Overhang Depth: 4.551 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.220
a. Electric Strip Heat
17.0 COPA.00
8. Skylights Area
c. U-Factor:(AVG) N/A ftz
15. Hot water systems
SHGC(AVG): N/A
a. Electric Tankless
Cap: 1 gallons
9. Floor,Types (990.0 sqft.) Insulation Area
ER 0.950
a. Slab -On -Grade Edge Insulation R=0.0 990.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
16. Credits
CF, Pstat
Glass/Floor Area: 0.118 Total Proposed Modified Loads: 29.43
PASS
Total Baseline Loads: 32.78
I hereby certify that the plans and specifications covered by
Review of the plans and
%ZUE STA?'
this calculation are in compliance with the Florida Energy
specifications covered by this
-
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: -9- O21
this building will be inspected for
compliance with Section 553.908
- ), ` . _ A&
hereby certify that this building, a designed, is in compliance
Florida Statutes.
with the Florida Energy ode
OWNER/AGENT: 'fir
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (111402.4.1.2).
4/8/2021 3:50 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Krueger Residence
Bedrooms: 1
Address Type:
Street Address
Building Type: User
Conditioned Area: 990
Lot #
Owner Name: Kristine Krueger
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
10900 Heil Road
Permit Office: St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County
Whole House Fan: No
City, State, Zip:
Fort Pierce,
Family Type: Detached
FL, 34945
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH _MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 990 9146
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 Bedroom 224
2329.6 No
2
1
1 Yes
Yes
Yes
2 M Bath 98
793.8 No
1
1 Yes
Yes
Yes
3 Craft Room 196
1587.6 No
2
1 Yes
Yes
Yes
4 Kitchen 126
1020.6 Yes
2
1 Yes
Yes
Yes
5 Closet 35
283.5 No
0
1 Yes
Yes
Yes
6 Bath 30
243 No
1
1 No
Yes
Yes
7 Hall 15
121.5 No
0
1 No
Yes
Yes
8 Great Room 266
2766.4 No
2
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Bedroom 30 ft
224 ftz
1 0
0
2 Slab -On -Grade Edge Insulatio
M Bath 21 ft
98 ft2
1 0
0
3 Slab -On -Grade Edge Insulatio
Craft Room 16 ft
196 ft2
1 0
0
4 Slab -On -Grade Edge Insulatio
Kitchen 21 It
126 ft2
1 0
0
5 Slab -On -Grade Edge Insulatio
Closet 5 ft
35 ft2
____
1 0
0
6 Slab -On -Grade Edge Insulatio
Bath 1 ft
30 ft2
1 0
0
7 Slab -On -Grade Edge Insulatio
Hall 1 ft
15 flF
1 0
0
8 Slab -On -Grade Edge Insulatio
Great Room 33 It
266 ft2
1 0
0
4/8/2021 3:50 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1020 ft2
0 ft2
Medium
N
0.6
No
0.9
No 0
14.04
ATTIC
/
v
#
Type
Ventilation
Vent Ratio (1
in)
Area
RBS
IRCC
1
Full attic
Vented
150
990 ft2.
N
N
CEILING
#
Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented)
Bedroom
30
Batt
224 ft2
0
Wood
2
Under Attic (Vented)
M Bath
30
Batt
98 ft2
0.1
Wood
3
Under Attic (Vented)
Craft Room
30
Batt
196 ft2
0.1
Wood
4
Under Attic (Vented)
Kitchen
30
Batt
126 ft2
0.1
Wood
5
Under Attic (Vented)
Closet
30
Batt
35 ft2
0.1
Wood
6
Under Attic (Vented)
Bath
30
Batt
30 ft2
0.1
Wood
7
Under Attic (Vented)
Hall
30
Batt
15 ft2
0.1
Wood
8
Under Attic (Vented)
Great Room
30
Batt
266 ft2
0
Wood
WALLS
Adjacent
Space
Cavity Width Height
Sheathing Framing Solar Below
1
N
Exterior Frame - Wood
Bedroom
19 12
6 10
5
130.2 ft2
0
0.25
0.6
0
2
W
Exterior Frame - Wood
Bedroom
19 10
11 10
5
113.7 ft2
0
0.25
0.6
0
3
N
Exterior Frame - Wood
M Bath
19 14
0 8
1
113.2 ft2
0
0.25
0.6
0
4
E
Exterior Frame - Wood
M Bath
19 7
0 8
1
56.6 ft2
0
0.25
0.6
0
5
E
Exterior Frame - Wood
Craft Room
19 16
0 8
1
129.3 ft2
0
0.25
0.6
0
6
E
Exterior Frame - Wood
Kitchen
19 10
0 8
1
80:8 ft2
0
0.25
0.6
0
7
S
Exterior Frame - Wood
Kitchen
19 11
0 8
1
88.9 ft2
0
0.25
0.6
0
8
W
Exterior Frame - Wood
Closet
19 5
0 8
1
40.4 ft2
0
0.25
' 0.6
0
9
S
Exterior Frame - Wood
Great Room
19 14
9 10
5
153.6 ft2
0
0.25
0.6
0
10
W
Exterior Frame - Wood
Great Room
19 10
11 10
5
113.7 ft2
0
0.25
0.6
0
DOORS
#
Omt Door Type
Space
Storms
U-Value
Width
Height Area
Ft
In
Ft
In
1
N Insulated
M Bath
None
.39
2
10
6
10 19.4 ft2
2
S Insulated
Great Room
None
.39
3
6
10 20.5 ft2
4/8/2021 3:50 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
V #
Wall
Omt ID Frame Panes
Overhang
NFRC U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1
2
3
4
5
6
N 1 Vinyl Low-E Single
N 1 Vinyl Low-E Single
E 4 Vinyl Low-E Single
E 5 Vinyl Low-E Single
S 7 Vinyl Low-E Single
S 9 Vinyl Low-E Single
Yes 0.28 0.22 Y 14.6 ft2 1 ft 7 in 1 ft 4 in
Yes 0.28 0.22 Y 15.0 ft2 1 ft 7 in 1 ft 4 in
Yes 0.28 0.22 Y 4.0 ft' 1 ft 7 in 1 ft 4 in
Yes 0.28 0.22 Y 29.2 ft' 1 ft 7 in 1 ft 4 in
Yes 0.28 0.22 Y 9.0 ft2 8 ft 0 in 1 ft 4 in
Yes 0.28 0.22 Y 45.0 ft2 8 ft 0 in 1 ft 4 in
None
None
None
None
None
None
None
None
None
None
None
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000411 1067 58.54 109.9 .1338 7
HEATING SYSTEM
#
System Type
Subtype Speed Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None COPA 17 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split Singl SEER: 16 24 kBtu/hr cfm 0.7 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location EF Cap Use SetPnt
Conservation
1
Electric Tankless
Craft Room 0.95 1 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
V #
— Supply - —
Location R-Value Area
— Return — Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1
Attic 6 65 ft2
Attic 15 ft2 Default Leakage Attic (Default) (Default)
1 1
4/8/2021 3:50 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Coolin Jan
Heating Jan
Feb
Feb
Mar
Mar
Apr
Apr
Ma
May
Jun
Jun
Jul
Jul
Au
Aug
Se
Sep
Oct [[ ]]Nov
Oct [X]
Nov
Dec
Dec
Venting Jan
Feb
Mar
Apr
May
Jun
Jul
Aug
Sep
Oct [[XX])
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
6B
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Craft Room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
Default(8 lbs/sq.ft.
ft2
ft
0.3
Closet
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall
Default(8 Ibs/s .ft.
ft2
ft
0.3
Great Room