Loading...
HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL J - 50 SPANISH WAY(1)FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip. FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(1718.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 c. NIA R= ft2 4. Number of Bedrooms 1 d. NIA R= ft2 5. Is this a worst case? Yes 11. Ceiling Types(1336.0 sgft.) Insulation Area 6. Conditioned floor area above grade (ft2) 1306 a. Under Attic (Vented) R=30.0 1306.00 ftz Conditioned floor area below grade (ftz) 0 b. Knee Wall (Vented) R=19,0 30.00 ft2 c. N/A R= ft2 7. Windows(128.9 sgft.) Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Sgl, U=1.02 76.04 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 SHGC: SHGC=0.29 b. b. U-Factor: Sgl, U=1.03 40.00 ft2 C. SHGC: SHGC=0.27 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: Sgl, U=1.02 12.85 ft2 a. Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 14. Heating Systems kBtulhr Efficiency S. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor:(AVG) NIA NIA ft2 SHGC(AVG): NIA 9. Floor Types Insulation Area 15. Hot Water Systems a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ft2 a. ElectricTankless Cap: 1 gallons b. NIA R= ft EF: 0.600 c. NIA R= ft2 b. Conservation features None 16. Credits None Glass/Floor Area. 0.099 Total Proposed Modified Loads: 41.30 Total Baseline Loads: 43.21 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this', Code, calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed 6-�-2��� this building will be inspected for DATE: compliance with Section 553.908 Florida Statutes. li I hereby certify that this building, as de ' compliance' with the Florida Energy Cos OWNEW6 BUILDING OFFICIAL: DATE: - DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factorysealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNETIICC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 617/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE COTTAGE IMPACT Address type: Street Address Building Type: User Bedrooms: 1 Lot#. - Owner. WYNNE BUILDING CORP. Conditioned Area: 1306 Blodr/SubDiWsion: - Total Stories: 1 PlatBook: - Builder Name: WYNNE BUILDING CORP. Worst Case: Yes Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY Rotate Angle: 180 County: St. Lucie Jurisdiction: Cross Ventilation: No City, State, Zip: FT. PIERCE, FamilyType: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban Year Construct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daily temp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range _FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 13IM76.2001953125 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated -1 MASTER BEDROOM 234 1895.4 No 0 1 Yes Yes Yes _2 DEN 144 1166.4 No 0 Yes Yes Yes _3 SINK AREA 42 340.2 No 0 Yes Yes Yes _4 CLOSET 63 510.3 No 0 No Yes Yes _5 GREAT ROOM 452 3661.2 No 2 Yes Yes Yes _6 MASTER BATH 50 405 No 0 Yes Yes Yes _7 POWDER 25 202.5 No 0 No Yes Yes _8 KITCHEN 232 1879.2 Yes 0 Yes Yes Yes _9 LAUNDRY 40 324 No 0 No Yes Yes 10 STORAGE 24 192 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 1306 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins MASTER BEDROOM 31 0 234 ft 0.473 - 0.00 1.00 0.00 _2 Slab -On -Grade Edge Ins DEN 24 0 144it 0.473 - 0.00 1.00 0.00 _ 3 Slab -On -Grade Edge Ins SINK AREA 7 0 42 It 0.473 - 0.00 1.00 0.00 _4 Slab -On -Grade Edge Ins CLOSET 1 0 63ft 0.473 - 0.00 1.00 0.00 _5 Slab -On -Grade Edge Ins GREAT ROOM 32 0 452ft 0.473 - 0.00 1.00 0.00 6 Slab -On -Grade Edge Ins MASTER BATH 5 0 50 ft 0.473 - 0.00 1.00 0.00 _ 7 Slab -On -Grade Edge Ins POWDER 1 0 25 ft 0.473 - 0.00 1.00 0.00 _ 8 Slab -On -Grade Edge Ins KITCHEN 38 0 232 ft 0.473 - 0.00 1.00 0.00 _9 Slab -On -Grade Edge Ins LAUNDRY 1 0 40ft 0.473 - 0.00 1.00 0.00 _ 10 Slab -On -Grade Edge Ins STORAGE 21 0 24 ft 0.304 - 0.00 0.00 1.00 6/7/2021 11:47:00 AM EnergyGaugeS USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) _ 1 Hip Metal 1376 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1306 fP N N CEILING (Total Exposed Area = 1336 sq.ft.) # Ceiling Type Space R-Value Ins.Type Area U-Factor Framing Free. Truss Type _ 1 UnderAtlic(Vented) MASTER BEDROOM 30.0 Blown 234.Oftz 0.053 0.10 Wood _2 UnderAttic(Vented) DEN 30.0 Blown 144.Oft- 0.053 0.10 Wood _3 UnderAttic(Vented) SINK AREA 30.0 Blown 42.Oft2 0.053 0.10 Wood _4 UnderAttic(Vented) CLOSET 30.0 Blown 63.0fF 0.053 0.10 Wood _5 UnderAttic(Vented) GREAT ROOM 30.0 Blown 452.0ft2 0.053 0.10 Wood _6 UnderAttic(Vented) MASTER BATH 30.0 Blown 50.Oft2 0.053 0.10 Wood _7 UnderAttic(Vented) POWDER 30.0 Blown 25.0ft2 0.053 0.10 Wood _8 UnderAttic(Vented) KITCHEN 30.0 Blown 232.Oft2 0.053 0.10 Wood _9 UnderAttic(Vented) LAUNDRY 30.0 Blown 40.Ofe 0.053 0.10 Wood 10 UnderAttic(Vented) STORAGE 30.0 Blown 24.OfF 0.030 0.11 Wood 11 Knee Wall(Vented) GREAT ROOM 19.0 Blown 30.OW 0.045 0.11 Wood WALLS (Total Exposed Area = 1718 sq.ft.) Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the'Projecf'section on page 1. VAdjacent Cavity Width Height Area U- Sheath Frm. Solar Below # Omt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _ 1 S=>N Exterior Conc. Blk- Int Ins MASTER BEDROOM 4.1 18.0 0 8.0 1 145.5 0.149 0 0 0.30 0% _2 W=>E Exterior Conc. Blk- Intlns MASTER BEDROOM 4.1 13.0 0 8.0 1 105.1 0.149 0 0 0.30 0% _3 N=>S Exterior Conc. Blk- Intlns DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _4 W=>E Exterior Conc. Blk- Intlns DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _5 S=>N Exterior Conc. Blk- Intlns SINKAREA 4.1 7.0 0 8.0 1 56.6 0.149 0 0 0.30 0% 6 N=>S Exterior Conc. Blk - Int Ins GREAT ROOM 4.1 22.0 0 8.0 1 177.8 0.149 0 0 0.30 0% _7 W=>E Exterior Conc.Blk- Intlns GREAT ROOM 4.1 10.0 0 8.0 1 80.8 0.149 0 0 0.30 0% _8 S=>N Exterior Conc. Blk- Intlns MASTER BATH 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _9 N=>S Exterior Conc.Blk- Intlns KITCHEN 4.1 17.0 0 8.0 1 137.4 0.149 0 0 0.30 0% _ 10 E=>W Exterior Conc. Blk- IM Ins KITCHEN 4.1 16.0 0 8.0 1 129.3 0.149 0 0 0.30 0% _11 S=>N Exterior Conc. Blk- Intlns KITCHEN 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _ 12 N=>S Exterior Conc. Blk- Int Ins KITCHEN 4.1 35.0 0 8.0 1 282.9 0.149 0 0 0.30 0% _ 13 N=>S Exterior Conc. Bik - Int Ins STORAGE 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _ 14 N=>S Exterior Conc. Blk- Int Ins STORAGE 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.30 0% 15 NaS Garage Frame - Wood MASTER BEDROOM 11.0 30.0 0 8.0 0 240.0 0.092 0 0.23 0.30 0% DOORS (Total Exposed Area = 20 sq.ft.) Width Height # Ornt Adjacent To Door Type Space Stones U-Value Ft In Ft In Area _ 1 E=>W Insulated KITCHEN None 0.32 3.00 0 6.00 8 20.Oft2 6/7/2021 11".47:00 AM EnergyGauge® USA 7.0.00- FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 129 sq.ft.) / Wall -Overhang- / # Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation InteriorShade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N N 32.4ft- 1.0 ft 5 in 1.0 ft 5 in None None -2 W=>E 4 Metal low-E Single Yes 1.02 0.29 N N 18.4ft2 1.0 It 5 in 1.0 ft 5 in None None 3 N=>S 6 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft- 1.0 ft 5 in 1.0 ft 5 in None None _4 W=>E 7 Metal Low-E Single Yes 1.03 0.27 N N 40.0' 12.0 It 0 in 1.0 ft 5 in None None -5 S=>N 8 Metal Low-E Single Yes 1.02 0.29 N N 6.9ft' 1.0 ft 5 in 1.0 ft 5 in None None _6 E=>W 10 Metal Low-E Single Yes 1.02 0.26 N N 12.8ft' 1.0 It 5 in 1.0 It 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00026 881 48.35 90.78 0.0907 5.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation _ 1 280 W 280 ft- 35 ft 8 It 11 MASS # Mass Type Area Thickness FumitureFraction Space _ 1 Default(8lbs/sq.ft.) 0 ft' 0 ft 0.30 MASTER BEDROOM 2 Default(8lbs/sq.ft.) 0IF 0 It 0.30 DEN _3 Default(81bs/sq.R) 0IF 0 It 0.30 SINK AREA _4 Default(8lbs/sq.fL) 0 ft' 0 It 0.30 CLOSET -5 Default(8lbs/sq.ft.) 0 ft' 0 It 0.30 GREAT ROOM _6 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 MASTER BATH _7 Default(81bs(sq.ft.) Oft' Oft 0.30 POWDER _8 Default(8 lbs/sq.ft.) 0f2 Oft 0.30 KITCHEN _9 Default(8lbs/sq.ft.) Oft' Oft 0.30 LAUNDRY -10 Default(8lbs/sq.ft.) 0 ft' Oft 0.30 STORAGE HEATING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity -Geothermal Heatloump- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Heat Pump Split/Single HSPF: 8.20 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRIr Efficiency Capacity Air Flow SHR Duct Block kBtu/hr chn _1 Central Unit Split/Single SEER:14.0 29.0 0 0.80 sys#1 1 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt FixtureFlow Pipelns. Pipelength 1 Electric Tankless Garage 0.60 (0.60) 1.00 gal 61 gal 120 deg Standard None 82 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS /Duct --supply —Return— Air CFM 25 CFM 25 HVAC # �/ # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6.0 120 ft' Attic 6.0 45 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [] Feb [ ] Mar [ ] Apr [ j May Pq Jun [Xj Jul Pq Aug Pq Sep [ ] Oct [ ] Nov [j Dec Heating [X] Jan [X] Feb [X] Mar [ ]Apr 1] May 1] Jun [ ]Jut [ ]Aug [ ]Sep [ ]Oct [X] Nov [X] Dec Venting []Jan [] Feb [X] Mar [X] Apr [ ] May [I Jun [] Jul [ ] Aug [ ] Sep [X] Oct [Xj Nov [ ] Dec Schedule: HERS 2006 Reference Hours VThermostat Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 _ Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _ Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 _Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 617i2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. Y Owner. WYNNE BUILDING CORP. Jurisdiction: U Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General Acontinuous airbarriershall be installed in the building envelope. Air-permeableinsulationshall requirements The exteriorthermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior theme] envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing, and anddoors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation andcantilevered shall be permitted to be in contact with the top side floors) ofsheathing, orcontinuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawlspacewalls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garageseparation Air sealing shall be provided between the garage and conditionedspaces. Recessed lighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exterior wall and tubs shall separate them from the showers and tubs. beinsulated. Elechicallphonebox The air barrier shall be installed behind electrical or onexteriorwalls communication boxes or air -sealed boxes shall be installed. HVAC register booh HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade Conditioned floor area below grade (ft=) 7. Windows** Description a. U-Factor. Sgl, U=1.02 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.03 SHGC: SHGC=0.27 c. U-Factor. Sgl, U=1.02 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description U-Factor:(AVG) N/A SHGC(AVG): N/A THE COTTAGE,FT. PIERCE,FL, New (From Plans) Detached 1 1 Yes 1306 0 Area 76.04 ft2 40.00 ft2 12.85 ft2 4.701 ft 0.281 Area N/A ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ft2 b. WA R= ft2 c. N/A R= ft2 10. Wall Types(1718.3 sqft.) Insulation Area a. Concrete Block- Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 c. N/A R= ft2 d. N/A R= ft2 11. Ceiling Types(1336.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ft2 b. Knee Wall (Vented) R=19.0 30.00 ft2 c. WA R= ft2 12. Ducts, location & insulation level R ft2 a. a. Sup: Attic, Rat Attic, AH: Attic 6 120 b. C. 13. Cooling Systems kBtu/hr Efficiency a. Central Unit 29.0 SEER:14.00 14. Heating Systems kBtu/hr Efficiency a. Electric Heat Pump 27.0 HSPF:8.20 15. Hot Water Systems a. ElectricTankless Cap: 1 gallons EF: 0.600 b. Conservation features None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. \\ \ Builder Signature: Date: Address of New Home: THE COTTAGE City/FL Zip: FT. PIERCE,FL, *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 677/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 wrightsoft® Project Summary o y: Entire House BF QUICK CALCS, INC. 317 ST. LUCIE LANE, FORTMERCE, FL34946 Phom:772-466-6799 Email: QUICKC4LCS AOL.COM Project• • For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16327 Btuh Structure 15522 Btuh Duds 4013 Btuh Duds 5251 Btuh Central vent (0 cfim) 0 Btuh Central vent (0 cfnT) 0 Btuh none Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20340 Btuh Use manufacturer's data n Rate/swingg multipplier Equipmentsensibleload 0.95 Infiltration 19734 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2094 Btuh Duds 1524 Btuh Central vent (0 cfm) 0 Btuh g Area ftz He 1tin0g Area Coolingg (none) (T (ft') 9 Equipment latent load 3618 Btuh 11309 MoluAir 105 changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 23352 Btuh Equiv.AUF(cfn) 79 41 Req. total capadty at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO3000GOA0 Cond CH14NB03000GOAO AHRI ref 9162387 Coil FX4DNBO43L AHRI ref 9162387 Efficiency 8.2 HSPF Efficiency 11.5 EER,14 SEER Heatinginput Sensiblecooling 20300 Btuh Heating output 28000 Btuh @47-F Latentcooling 8700 Stuh Temperature rise 26 OF Total cooling 29000 Btuh Actual air low 967 din Actual airflow 967 cfin Airflowfactor 0.048 ctm/Btuh Airflowfador 0.047 cfm/Btuh Static pressure 0.50 in H2O Staticpressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point = 34 OF Backup: Input=5kW, Output= 18005 Btuh, 100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wr110•ft6tI 2021-Ja,121321:40 '� •� �w RgttSULOUrivemI201919.021 RSU08101 Page 1 ...1WdgttsoltFNAQWYNNESUIDLING-THECOT-rAGE.np Calca W8 FrortDoorfaces:SW wrightsoft° Right-J@ Worksheet Joe: Entire House Date: QUICK CALCS, INC. By. 317ST.LUCIEU ,FORT PIFRCE,FL34946Phwe:72-06 798 E I:QUICKC CSOAOLOOM 1 Room name Emre House MASTER BEDROOM 2 Evosed%nell 145.0 It 31.0 2 3 Room height 8.1 ft 8.1 ft heaVmd 4 Room Eimensons 13D X 18.0 ft 5 .Room area 1306D fF 234.0 T Ty Construction U-wlue Or HTM Area (� � number (BWhdl-n (Bluh0f) or perimeter (ft) (BWh) a perimeter (1) (BWh) Heat Cool G. N/P/S Heat Cool G. NIPS Heat Cool 6 V// 13A-4= 0.143 n 4.00 219 446 427 1710 934 0 0 0 0 t—G 2glaarg,droutr, 1jW n 29.12 21.68 18 0 537 400 0 0 0 - 0 1344ons 0.143 a 4.00 2.19 162 129 516 282 0 0 0 0 2gglazirlg, droulr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 11D0 0.390 a 1092 10.34 20 20 223 211 0 0 0 0 IL-6 13A-4= 0.143 s 4.00 219 284 277 1107 635 w146 584 319 2glazig,droutr, 1D40 s 29.12 21.68 7 7 202 150 0 0 0- 0 13A-0as 0.143 w 4.00 219 284 192 767 419 106 73 291 159 tAa7om 1270 w 3555 34.77 41 41 1451 1419 0 0 0 0 1Ah1om 1270 w 3556 61.76 18 3 656 1139 0 0 0 0 1Ah1om 1270 w 3556 63.40 33 5 1162 2072 33 5 1162 2072 c - - 16C30ml 0.032 - 090 128 1306 1306 - 1170 1672 234 234 - 210 300 F 22A-10 0289 - 27B9 ODO 1306 145 4015 0 234 31 858 0 6 c)AED exurson 3591 997 Ernelope loss/gain 13BB5 13393 3105 3847 12 a) tlfilrtation 2441 668 522 143 b) Roomeenfilafion 0 0 0 0 13 Intemalgains Ooupana@ 230 2 460 0 0 Applianasotlxr 1000 0 Subbtal(lines64713) 16327 15522 3627 3990 Lessel4emalload 0 0 0 0 Lesstranster 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 16327 1� 3627 3990 15 Dud 25% 34% 4013 5251 25% 34% 892 1352loatls 1352 Toial mom bad 20340 20773 4518 5242 Air required (dm) 967 967 215 249 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed r+glfL9oec- RigrtSdldve [e®trsa1201979.021 RW S8101 2021Jarv121321:40 ACLA ...1WngfisoftHVAL1WVNNE BUIOLING-THE COTiAGE4tp Calc=M16 RortWorfaces:SW Page 1 wrightsoft° Right-J® Worksheet 'Ob" Entire House Daft: QUICK CALCS, INC. By. 317 ST.. LUCIE LANE, FORTPIERCE, FL34946 Phone: 772-06&6799 EmaiI:QUICKCALCS@AOL.COM 1 2 3 Roomreme EVOSedwell Room height DEN 24.0 It 8.1 R heaf/o3ol SWAREA 7.0 tt 8.1 It heaHmol 4 5 Room tlimensons Room area 12.0 x 120 It 144.0 if 6D x 7A It 42.0 T Ty Construction member 11-Ndue (BL dQ'L'F) Or HTM (BWhfin Area (tF) or perimehar (e) Load (Bluh) Area or perimeter (to Load (Bluh) Heat Cool G. NIPS Heat Cool Gross Nh'S Heat Cool 6 11 Yy �C 13A4= 2gMr,,,droutr, 13A4= 2gWzJng,droutr, 1100 13A4= 2glaang,droutr, 13A4= lAclom lA-hlom lA-htom 16G-30mf 22A-Q11 0.143 1.040 0.143 1040 0.390 0.143 1.040 0.143 1270 1270 1270 0.032 0.989 n - n a a a s s w w w w - • 4DO 29.12 4.00 29.12 10.92 4110. 29.12 4.00 3556 3556 3556 0.90 27.6.9 2.19 21M 219 39.42 10.34 219 21M 2.19 34.77 61.76 63.40 128 OR 97 - 0 0 0 0 0 0 97 0 18 0 144 144 97 0 0 0 0 0 0 79 0 3 0 144 24 389 0 0 0 0 0 0 315 0 656 0 129 665 213 0 0 0 0 0 0 172 0 1139 0 184 0 0 0 0 0 0 57 0 0 0 0 0 42 42 0 0 0 0 0 57 0- 0 0 0 0 -. 42 7 0 0 0 0 0 227 0 0 0 0 0 38 194 0 0 0 0 0 124 0 0 0 0 0 54 0 W Y-9 C F 6 c)AEDe rson 574 S Envelope loss/gain 2154 2283 459 175 12 a) I16ltralion b) Roomlentilation 404 0 ill 0 118 0 32 0 13 Ntemal gains: Oompanls@ 230 Applianceyolher 0 0 D 0 0 0 Subbtal(lirles64r13) 2558 2394 576 207 14 15 Les odNnal load Leseander Redistibulion Subbtzl Ductloads 25% 34% 0 0 0 25M 629 0 0 0 2394 811 J 34% 0 0 0 576 142 0 0 0 207 70 Total room load Airrequretl (Qm) 3187 152 3205 149 718 34 278 13 Calculations approved byACCAto meet ail requirements of Manual J 8th Ed -r k- wrlghasoTt- 20214a 121321 rio RightSuteDLkiversal 201919.021 RSU08101 Page 2 ...\WdgYmtWAQWYNNEBUIDLING-7 iEOOT7AGE.ny Calc=Ml8 FrortDoorfaces SW wrightsoft- Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. t3y. 317 ST. LUCIE LINE, FORTPIERCE, FL34946 Prow 7724666799 EmaiI:QU1CKCALCS@AOL.COM 1 Room name CLOSET GREAT ROOM 2 EVosad wall 0 It 32.0 ft 3 Room height 8.1 ft heaHmol 8.1 It heatbD01 4 Room dimensions 9D x 7D ft 1D x 452D ft 5 Room area 63.0 IF 4520 B Ty Construction U--Aue or HTM Area Load Area (fF) Load number I (BWhWL*g (BIuW or perimeter (ft) (BWh) or perinneter (ft) (Ruh) Heat Cool Gross NPS Heat Cool Gross NIPS Heat Cod 6 W 13AA= 0.143 n 4A0 2.19 0 0 0 0 178 160 640 350 �C 2glaang,droutr, 1A40 n 29:12 21.68 0 0 0 0 18 0 537 40D 13A = 0.143 a 4D0 219 0 0 0 0 0 0 0 0 2glaang,droutr, 1.OA a 29.12 39.42 0 0 0 0 0 0 0 0 11 11D0 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 t1344ats 0.143 a 4DO 2.19 0 0 0 0 0 0 0 0 2glaang,droutr, 11M1 5 29.12 21.6E 0 0 0 0 0 -0 0- 0 —G 13A-4ocs 0.143 w 4.00 2-19 0 0 0 0 81 40 161 88 1A Iom 12M w 35M 34.77 0 0 0 0 41 41 1451 1419 1A-h1om 12M w 35M 61.76 0 0 0 0 0 0 0 0 IA-hlom 1270 w 3556 63AO 0 0 0 0 0 0 0 0 C 16c-mml Om - ODD 128 63 63 56 81 452 452 405 579 F 22A-tpl OM - 27B9 ODD 63 0 0 0 452 32 886 0 6 c)AEDexansion -1 2069 Envelope lcss/pn 56 801 4080 4903 12 a) Infiltration 0 0 539 148 b) RoomlenNalion 0 0 0 0 13 Irlbrrlal gars Oovpanls@ 230 0 0 2 460 Applianceslather 0 0 Subtotal (fines6to 13) 56 80 4619 5511 leasexemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 80 4619 5511 15 Dudloads 25% 34% 14 27 25% 34%j 1135 1868 Total room bad 1 70 107 5754 7379 Air lequired(dm) 1 3 5 274 343 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed -►I wr�9titsoTc^ 20214k 121321r10 Fish RigltSute®Uriwrsa1201919D21 RSU08101 Page3 ...IWng%oft FNAC1WYNNEBUIDLING-7HECOTTAGExW Calc=MIB FrorfDoorfaca&SW wrightsoft, Right-J@ Worksheet Job: Entire House Data: QUICK CALCS, INC. By. 317 ST.. LUCE LANE, FORPPIERCE, FL34946 Phore: 7724666799 Email: QUICKCALCS@oAOLCOM 1 Room name MASTER BATH POWDER 2 EVos:dwall 5A ft 0 R 3 Room height &1 R heaUmol 8.1 ft heaY000t 4 5 Roomdimertiom Roomarea 10.0 x 5.0 ft SDA fF 5.0 x 5.0 R 25.0 fP Ty Conshuchon number U-value (BbjhV-°F) Or HTM (Bbh'V) Area (fe) or perimeter (ft) Load (BWh) Area (fF) Of Perimeter (ft) Load (Bluh) Heat Cod Gross NiP/S Heat Cool Gross NIPS Heat cool 6 Vil 13A4c s 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 �C W/ 2glaang,droulr, IMAM 1.040 0.143 n a 29.12 4A0 21.68 2.19 0 0 0 0 0 0 0 0 0 0 0 0 0 0- 0 0 11 {`—DG 2glazug,droufr, 1100 1A40 0.390 a a 29.12 10.92 39.42 10.34 0 a 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W I a 13A�4ar_s 2glaang.droutr, 13A4o s 0.143 1.040 0.143 5 s w 4A0 29.12 4,00 2.19 21.68 2.19 -41 7 0 34 7 0 134 202 0 73 150 0 0 0 0 0 .0 0 0 0 0 - 0 0 0 1Ac1om 1A-h1w 1270 1270 w w 35M 3555 34.77 61.76 0 0 0 0 0 0 0 0 0 0 0 a 0 0 0 0 c F tAhlom 16C30mi 22AApl 1270 OA32 0.989 w - - 35.56 090 27.E 63.40 12B OAO 0 50 50 0 - so 5 0 45 138 0 - 64 0 0 25 25 0 25 0 0 22 0 0 32 0 6 c)AEDe=rsim 4 0 Envelope losVgain 520 294 22 32 12 a) Mliation 84 23 0 0 b) Rcom1 blation 1 0 0 0 0 13 Inkmd grins: O—pants@ 230 0 0 0 0 Appli rxoesother 0 0 Subbtal(lines6to13) 604 307 22 32 Lesser alload 0 0 0 0 14 Lesshansfar Redstibubon Subtotal 0 0 604 0 0 307 0 0 22 0 0 32 15 Dudloads 25% 34% 148 104 251; 34 6 11 Total room bad Air required (dm) 752 361 411 19 28 1 42 2 Calculations approved bvACCAto meet all reauirements of Manual J 8th Ed �I w� ti�aR 2021-JaM21321AO .4�A R(3-THECOTrAGExt01919.02 B Fror 101 Page4 ...\Wngtl=oR HUACIWYNNE BUIDLING-iHE COTTAGEnp CaIc=M18 FrortOaorfaces:SW wrightsoft- Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317ST. LUCIE LANE, FORTPIERCE, FLU946 Phore:772.466-6799 EmaiI:OUICKCALCS AOL.COM 1 Room name KfrCHEN LAUNDRY 2 Exposedwall 38A ft 0 It 3 Room height 8.1 ft heakool 8.1 It hea0mol 4 Room dimensions 1.0 x 232.0 ft 4.0 x 10.0 ft 5 Room area 232.0 It' 40D fP Ty Construction U-value Or HTM Area Load number I (Btuhd--°rg (Bbadft or perimeter (ft) (Btoh) or (ft) (Bluh) Heat Cool Gross NIPS Heat Cool Gross N/P/S Heat Cool 6 W 13A4= 0.143 n 4.00 2.19 138 138 551 301 0 0 0 0 �G 2glaang,droufr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A-4= 0.143 a 4.00 2.19 130 97 387 211 0 0 0 0 2 glazing, croutr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 11DO 0.390 a 1022 10.34 20 20 223 211 0 0 0 0 M1 13A4= 0.143 s 4.00 219 41 41 162 89 0 0 0 0 t--C 2glazing,droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 13A4= 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 tAclom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 IA-hlom 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 1A-hlom 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16330m1 0.032 - 090 128 232 232 208 297 40 40 36 51 F 22A-Ipl 0.989 - 27.69 0.00 232 38 1052 0 40 0 0 0 6 c)AED emersion _87 -1 Envelope los(gain 2951 1570 36 51 12 a) Infiltration 640 175 0 0 b) Roomsantilaton 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoesbther 100D 0 Subtotal(lines6b13) 3591 2745 36 51 Lessextomalload 0 0 0 0 Les7ransrer 0 0 0 0 Redistibulion 0 0 0 0 14 Subtotal 3591 2745 36 51 15 Ductloads 25% 34% 883 931 25/ 34/ 9 17 Total room load 4474 3676 45 68 Air required (cfm) 213 171 2 3 Calculations approved byACCAto meet all requirements of Manual J 8th Ed wry9h�nR' 2021-Jar+121321:40 Afth Rigk-SdL&Uriwrsl201919.021 RSU08101 Page 5 ...\WngrGoft HVAC\WYNNESUIDLING-THECOTrAGE.np Calc=MI8 Frorf Doorfaoes SW wrightsoft° RighW@ Worksheet Job: Entire House °fit QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34M Phore: 772466-6799 Email: QUICKCA.LCS AOL.COM 1 Room name STORAGE 2 E>posedxall 8.0 R 3 Room height 8.1 It heaqh) 4 Room dimensions 4.0 x 6.0 5 Room area 24D 1p Ty Consruaon U-value Or HTM Area (T) LoaArea Load number (BWhAf---F) (BWhlft' or perimeter (ft) (BWor perimeter Heat Cool Gros NIPS Heat Gros NIPS Heat Cool 6 Vf/ 13A-4ocs 0.143 n 4.00 2.19 32 32 130�C2glaarg,droutr, 1.040 n 29.12 21.68 0 0 013A-4 'NBC s 0.143 a 4.00 2.19 32 32 13071 2glaang,droutr, 1.040 a 29.12 39.42 0 0 0 0 11 `D 11DO 0.390 a 10.92 10.34 0 0 0 0 Vy 13A-0as 0.143 s 4.00 2.19 0 0 0 0 I-6 2gla2irg,droutr, 1.040 s 29.12 21.68 0 0 0 0 13A-0as 0.143 w 4.00 2.19 0 0 0 0 1Ac1om 1270 w 3556 34.77 0 0 0 0 1A-h1om 1270 w 3556 61.76 0 0 0 0 1A-h1om 1270 w 3556 63.40 0 0 0 0 C 16C30ml UK - 0.90 128 24 24 22 31 F 22A-Ipl 0.989 - 27.69 0.00 24 8 222 0 6 c)AEDexansion -3 Enuelope loss(gain 502 170 12 a) Infiltration 135 37 b) Room ver141ation 0 0 13 Internal gains: Cmipants@ 230 0 Appliancesrother 0 Submlal(lirres6to13) 637 207 Lessex�malload E25% 0 0 Leatransfer 0 0 Redistribution 0 0 14 Subtotal 637 207 15 Dudloads 299% 157 60 Total room load 794 266 Air required (di 38 12 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed - wra9�+Cso/2� 2021-JaM21321:40 RigrtTHECO rrAGE..nip Ca9.=M RS rortDo Page6 ...1WngdsoRFNAgWYNNE BUIDLING-h1E COTiAGE.np Calc=N76 FrortDoorfares:SW - wrightsoft® Duct System Summary o: Entire House BF QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 PhDm: T72466-6799 Email: OUICKCALCS ,AOLWM For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in H2O 028 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 dim 126 Supply Branch Detail Table Cooling 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.11010.110 in H2O 0.080 in/100ft 967 c5n Name Design (Btuh) Htg (dn) Clg (cfm) Design FIR Diam (in) H x W (in) Dud Mat Actual Ln (8) Ftg.Egv Ln (ft) Trunk CLOSET C 107 3 5 0.080 4.0 Ox0 VIFx 24.6 90.0 st1 DEN h 3187 152 149 0.080 7.0 Ox0 MFx 33.5 90.0 st1 GREATROOM C 3689 137 172 0.080 8.0 OxO VIFx 14.6 70.0 GREATROOM-A c 3689 137 172 0.080 8.0 Ox0 VIFx 16.1 70.0 KITCHEN h 4474 213 171 0.080 7.0 Ox0 VIFx 4.5 70.0 LAUNDRY c 68 2 3 0.080 4.0 OxO VIFx 5A 70.0 MASTERBATH h 752 36 19 0.080 4.0 0x0 VIFx 32.9 90.0 st1 MASTERBEDROOM C 2671 107 124 0.080 7.0 OxO VIFx 27.9 90.0 st1 MASTERBEDROONLA C 2671 107 124 0.080 7.0 OxO VI Fx 35.9 90.0 st1 POWDER c 42 1 2 0.080 4.0 OxO VIFx 292 90.0 stl SINKAREA h 718 34 13 0.080 4.0 0x0 VIFx 30.9 90.0 st1 STORAGE h 794 38 12 0.080 4.0 OxO VIFx 112 70.0 Supply Trunk Detail Table Name Trunk Type Htg (Cfm) Clg (CfiT1) Design FIR Veloc (fpm) Diam (in) HxW (in) Duct Material Trunk st1 PeakAVF 441 437 0.080 561 12.0 0 x 0 VinlFlx WrighlsoR^ 2021Ja 121321:41 •r++-! 4�.., PogkSUte4JUriversa120t919.021 RSU08101Xck Pagel ...\w6gtfsoftWAQWYNNEBUIDLING-THECOTFAGE.rLp CaIc=MJ6 FmrtDoorfa=SW Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Dud Matl Trunk rb1 Ox0 967 967 0 0 0 0 Ox 0 VIFx o * wrightsoft2021-Jao-121821:41 •4 � wm-.,�.-, Ri9kSute&Uriversa1201919,021 RSU08101 Page ...\WdgFtsDft WAQWYNNESUIULING-THECATTAGE.np Caic=MJS RortWoriaces SW