Loading...
HomeMy WebLinkAboutPermit WorksheetMobile Home Permit Worksheet Installer: EDDIE GRUNDEL Address of home 5821 S HEADER CANAL RD being installed FT PIERCE Manufacturer JACOBSEN License # IH1118467 Length x width 32X68 NOTE. if home is a single wide fill out one half of the blocking plan if home is a triple or quad wide sketch in remainder of home I understand Lateral Arm Systems cannot be used on any home (new or used) where the sidewall ties exceed 5 ft 4 in. Installers initials EG Typical pier spa::�� in 9' 61 I lateral � Show locations of Longitudinal and Lateral Systems longitudinal (use dark lines to show these locations) I t:T --r Lj Li Li Ej --- :-----------------------n - --------------------------n ------------------------ 4U - - - - maniage wall piers within 2' of end of home per ule 15C Application Number: Date: New Home Q Used Home Home installed to the Manufacturers Installation Manual Home is installed in accordance with Rule 15-C 8✓ Single wide Wind Zone II Wind Zone Ili �✓ Double wide ✓] Installation Decal # TBD Triple/Quad ❑ Serial # TBD PIER SPACING TABLE FOR USED HOMES Load bearing capacity Footer size {sq in) 16" x 16" (256) 181/2" x 18 1/2" (342) 20" x 20" (400) 22" x 22" (4a4)* 24" X 24" (576)" 26" x 26" (676) 1000 Dsf3 4 1500 Dsf4' V16 7 8 00 pst I6 8 8 8 2500 s 3000 pst I 8 8 8' 3500 pSt8 1 81 1 81 1 6, 1 8' m►crpuiamu uunr rwic ia%.-t pier spacing tame. PIER PAD SIZES I-beam pier pad size 17X22.5 Perimeter pier pad size 16X16 Other pier pad sizes (required by the mfg.) Draw the approximate locations of marriage wall openings 4 foot or greater. Use this symbol to show the piers. List all marriage wall openings greater than 4 foot and their pier pad sizes below. iK]"ilLi'i►�c;►L! t��• sue, il�L�lfiC:3'y:��ifi[:11�J♦'I illlllllllllllll�.r�z��l� ANCHORS 4ft —V'f-5ft— — FRAME TIES within 2' of end of he -- spaced at 5' 4" oc _ V( _ TiEDOWN COMPONENTS OTHER TIES Number Longitudinal Stabilizing Device (LSD) Sidewall Manufacturer QLIVER Longitudinal Longitudinal Stabilizing Device w/ Lateral Arms Marriage wall Manufacturer Shearwall Opening 1-4 Pier pad size 17X22.5 2-3, 23X31 Page 1 of 2 Mobile Home Permit Worksheet Application Number: Date: POCKET E TRO TE E T The pocket penetrometer tests are rounded down to 1500 psf or check here to declare 1000 lb. soil without testing. X 1,500 X 1,500 X 1,500 POCKET PENETROMETER TESTING METHOD 1. Test the perimeter of the home at 6 locations. 2. Take the reading at the depth of the footer. 3. Using 500 lb. increments, take the lowest reading and round down to that increment. X 1,500 X 1,500 X 1,500 TORQUE PROBE TEST The results of the torque probe test is 290 inch pounds or check here if you are declaring 5' anchors without testing . A test showing 275 inch pounds or less will require 5 foot anchors. Note: A state approved lateral arm system is being used and 4 ft. anchors are allowed atthe sidewall locations. I understand 5 ft anchors are required at all centerline tie points where the torque test reading is 275 or less and where the mobile home manufacturer may requires anchors with 4000 lb holding capacity. Installer's initials ALL TESTS MUST BE PERFORMED BY A LICENSED INSTALLER Installer Name EDDIE GRUNDEL Date Tested Electrical Connect electrical conductors between multi -wide units, but not to the main power source. This includes the bonding wire between mutt -wide units. Pg. Plumbing Connect all sewer drains to an existing sewer tap or septic tank. Pg. Site Preparation Debris and organic material removed X Water drainage: Natural Swale Pad X Other Fastening multi wide units Floor: Type Fastener: LAG Length: s" Spacing: 24" Walls: Type Fastener. LAG Length: s" Spacing: 24" Roof. Type Fastener: GALy Length: CONT Spacing: 24" For used homes a min. 30 gauge, 8" wide, galvanized metal strip will be centered over the peak of the roof and fastened with galy. roofing nails at 2" on center on both sides of the centerline. Gasket (weatimprwfin9 regLdmmew) -- I understand a properly installed gasket is a requirement of all new and used homes and that condensation, mold, meldew and buckled marriage walls are a result of a poorly installed or no gasket being installed. I understand a strip of tape will not serve as a gasket. Installer's initials Type gasket FACTORY FOAM Installed: Pg. Between Floors Yes X Between Walls Yes X Bottom of ridgebeam Yes x Weatherproofing The bottomboard will be repaired and/or taped. Yes X . Pg. Siding on units is installed to manufacturer's specifications. Yes x Fireplace chimney installed so as not to allow intrusion of rain water. Yes X Miscellaneous Skirting to be installed. Yes X No Dryer vent installed outside of skirting. Yes X N/A Range downflow vent installed outside of skirting. Yes X N/A Drain lines supported at 4 foot intervals. Yes X Electrical crossovers protected. Yes X Other: Installer verifies all information given with this permit worksheet Is accurate and true based on the manufacturer's installation instructions and or Rule 15C-1 & 2 Connect all potable water supply piping to an existing water meter, water tap, or other Installer Signature independent water supply systems. Pg. Date Page 2 of 2