Loading...
HomeMy WebLinkAboutSurveyr GRAPHIC SCALE 50 300 600 ( IN FEET ) I inch = 300 ft. 1200 203'47"w 4123.4C NOO°03'47"W 506 00' FD 5/8" IR/C (MIXON LS3335) SET 5/8" IR/C SET 5/8IR/C N 1.56' (LB8098) (LB8098) E 1.88' t ^ I 0 z � a �- 0 �I z o- 0 ^ z V w I 0 0 M E U z Aa • o Ld 0 .I m D' F Q , D o cn .I w z_ 49.00' t:±i cD -j FD 3"x3" CM z (NO IDENTIFICATION) (n E 1.32' a � W o n — U Z — = CW00 ! DITCH CONTROL oa- STRUCTURE uj z) Q d-z :z — — GATE GATE- 47 n (O Lo N M N 0 NN N 3-WIRE FENCE X loo 3 SOUTH OF R) o� x x X I r 0 LJ {F ZI LLI x I O x 49.00' o FD 4"x4" CM %< (BROKEN) S 0.14', W 0.72' OHW — — I o i W U Z W LL uj I m Q m / 't NE 1 /4 SECTION 11 SET 5/8" IR/C (LB8098) Do - - EAST 1 4 CORNER o SECTION 11 (HISTORIC DATA) - - N 41893748442 ----- -- -- -- - E 819228.5342 Lo n S jTE PLAN ` 0 TS: * FINISHED FLOOR ELEVATION 18" ABOVE CENTER OF ROAD PER BUILDING DEPARTMENT PUBLIC UTILITIES ARE NOT AVAILABLE S00°03'47"E 507.41' 4' BARB -WIRE FENCE (4.3'-4.8' WEST OF IL') SET 5/8" IR/CH 8'-10't WIDE DITCH (LB8098) 49.00' I� w ON Z 2 I� w Ty O 0 m i_ NORTH 1062.41' DETAIL"' =max , 5%$"' F -I 1 aST. LUCIE COUNx L-J"} VE ICAL CONTROL DISK*'"" . Z "HC-1" EL 22.30'-\ POINT #20001 S00"g1'g5"w .rinF; nw u= 8'-10't WIDE DITCH I 8'-10't WIDE DITCH SET 5/8" IR/C (LB8098) /(1.7'-14.8' BARB-WIRE FENCE WEST OF R) � I IN M 00 0 N � w�a OS y u-) I � 00 Z 0 I ( I �.. E"A D 9 W�"..--C A N A_ L 0 A -- - UHW --- QHW - o - LB8098) 1 _ - w WAY) - - - - - - —TD IVAG"NA1L& WASHER - NORlTTnST_CMIVER-- - _ _ H E A D _ '' R C iA N A L _(SLC PLS419gj O - S . 11 HISTORIC DATA)_ EAST LINE SECTION 11 (68.00' RIGHT-OF-11iAY) N 17.23', W 33.25' o N 11 030 01.0501 44.9015 N _S . L ._R . W. C. D. C A N A L N 0 8 0- - (68.00' RIGHT-OF-WAY) - - - k �U ST. LUCIE COUNTY, FLORIDA VICINITY MAP NO SCALE �N SCALE: 1 "=40' SURVEYORS NOTES AND REPORT: 1. REPRODUCTIONS OF THIS MAP ARE NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER, THIS SURVEY CANNOT BE TRANSFERRED OR ASSIGNED WITHOUT THE SPECIFIC WRITTEN PERMISSION OF ENGINEERING, DESIGN AND CONSTRUCTION, INC. IT IS A VIOLATION OF CHAPTER 5J-17, FLORIDA ADMINISTRATIVE CODE, TO ALTER THIS SURVEY WITHOUT THE EXPRESS PRIOR WRITTEN CONSENT OF THE SURVEYOR. ADDITIONS AND/OR DELETIONS MADE TO THE FACE OF THIS SURVEY WILL MAKE THIS SURVEY INVALID. 2. CURRENT DESCRIPTION(S) SHOWN HEREON PROVIDED BY THIS OFFICE. 3. PARCELS CONTAIN A TOTAL OF 23.65 ACRES MORE OR LESS. 4. SUB -SURFACE IMPROVEMENTS INCLUDING UNDERGROUND UTILITIES, UTILITY SERVICES, WERE NOT LOCATED AS PART OF THIS SURVEY. SUB -SURFACE IMPROVEMENTS SHOWN ARE BASED ON REFERENCE MATERIAL AND AS -BUILT RECORDS PROVIDED BY THIS OFFICE AND THE DEVELOPER. UNDERGROUND UTILITIES SHOWN HEREON MAY HAVE BEEN REMOVED. 5. THE LAST DATE OF FIELD WORK WAS MAY 27, 2021. 6. REVISIONS SHOWN HEREON DO NOT REPRESENT A "FIELD SURVEY UPDATE" UNLESS OTHERWISE NOTED. 7, BEARINGS SHOWN HERON ARE BASED UPON THE EAST LINE OF SECTION 11, TOWNSHIP 36 SOUTH, RANGE 38 EAST, PER THE LINE LABELED HERON AS (BEARING BASIS) AND ALL OTHER' BEARINGS ARE RELATIVE THERETO. DISTANCES ARE IN U.S. SURVEY FEET AND DECIMAL PARTS THEREOF. B. IN SOME INSTANCES, GRAPHIC REPRESENTATIONS AND SYMBOLS SHOWN HAVE BEEN EXAGGERATED TO MORE CLEARLY ILLUSTRATE THE RELATIONSHIP BETWEEN PHYSICAL IMPROVEMENTS AND/OR LOT LINES. THE DIMENSIONS SHOWN SHALL CONTROL THE LOCATION, OF THE IMPROVEMENTS, OVER THE SCALED POSITIONS.- 9. THE OWNERSHIP OF PERIMETER FENCES, WALLS, HEDGES LANDSCAPING, IF ANY, SHOWN HEREON ARE NOT KNOWN AND ARE NOT LISTED AS ENCROACHMENTS. THEIR RELATIVE LOCATION IS SHOWN IN RELATION TO THE BOUNDARY LINES SHOWN. 10. THE SURVEY MAP SHOWN HEREON DOES NOT NECESSARILY CONTAIN ALL OF THE INFORMATION OBTAINED OR DEVELOPED BY THE UNDERSIGNED SURVEYOR IN HIS FIELD WORK,' OFFICE WORK OR RESEARCH. 11. THE HEREON DESCRIBED PROPERTY IS LOCATED WITHIN AREA OF MINIMAL FLOODING, FLOOD HAZARD ZONE DESIGNATION "X", ACCORDING TO (UNPRINTED) FLOOD INSURANCE RATE MAPS NO. 12111CO250J AND 12111CO255J, SAINT LUCIE COUNTY, FLORIDA, BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY (F.E.M.A.). 12. THE EXPECTED USE OF THE SUBJECT PROPERTY FALLS WITHIN THE RESIDENTIAL CATEGORY AS CLASSIFIED IN CHAPTER 5J-17.051(15)(8)(I1), FLORIDA ADMINISTRATIVE CODE. ALL FIELD -MEASURED CONTROL MEASUREMENTS EXCEEDED 1: 10,000 FEET ACCURACY REQUIREMENTS FOR THIS CLASSIFICATION. REDUNDANT MEASUREMENTS PRODUCED AN AVERAGE ACCURACY OF 0.08't HORIZONTALLY AND 0,16't VERTICALLY. 13. THE CPS SOFTWARE USED FOR THIS PROJECT: TDS SURVEY PRO, VERSION 4.95, /REALTIME PROCESSING IS BASED ON THE TRIMBLE RTKLINK NETWORK. NORTHING AND EASTING COORDINATES ARE BASED ON NAD 83 STATE PLANE DATUM (FLORIDA EAST) ZONE. THE PROCEDURES AND NETWORK DESIGN MEETS THE GEODETIC ACCURACY STANDARDS AND SPECIFICATIONS FOR USING GPS RELATED POSITIONING AS SET FORTH BY THE FEDERAL GEODETIC CONTROL COMMITTEE IN THE MOST CURRENT PUBLICATION FOR 3RD ORDER CLASS ONE FOR HORIZONTAL CONTROL SURVEYS. LE AL DESCRIPTION: THE SOUTH 506 FEET OF THE NORTH 1062.41 FEET OF THE FOLLOWING DESCRIBED PARCEL: THE NORTHEAST 1/4 OF SECTION 11, TOWNSHIP 36 SOUTH, RANGE 38 EAST, LESS RIGHT-OF-WAY FOR PUBLIC ROADS AND DRAINAGE CANALS, ST. LUCIE COUNTY, FLORIDA. CONTAINING 1,030,194 SQUARE FEET (23.65 ACRES), MORE OR LESS. SYMBOL LEGEND TEL = AT&T RISER ° ° ^ = GUARD RAIL WVDQ = WATER VALVE BFP-+ = BACK FLOW PREVENTER GUY WIRE ANCHOR = WOOD POLE STREET LIGHT FOR = BENCH ® =HANDICAP =WOOD POWER POLE = BENCHMARK = HYDRANT QT = TRAFFIC HANDHOLD QJI = BIKE RACK ® = IRRIGATION CONTROL VALVE HH = UNKNOWN HANDHOLD CAN ❑ = CABLE RISER IRRP O = IRRIGATION PUMP RISER = UNKNOWN RISER. BOX BOX ® = CABLE/TV HANDHOLD OC = IRRIGATION VALVE —BPM— = BLUE PAINT MARKS ® =. CATCH BASIN LSA =LIMITS OF LANDSCAPING _RPM_ = RED PAINT MARKS LIMITS OF TREE CANOPY C00 = CLEAN OUT `'� BUSH/HEDGE —GPM— = GREEN PAINT MARKS } = CONCRETE LIGHT POST '),,X = LIGHT POST —OpM_ = ORANGE PAINT MARKS CPP ®= CONCRETE POWER POLE 21 = MAILBOX —WPM— = WHITE PAINT MARKS = CONCRETE POWER POLE W/STREET LIGHT = METAL LIGHT POST =RED FLAG. = CONCRETE SIGNAL LIGHT POLE ® = MONITORING WELL = WHITE FLAG = DECORATIVE LIGHT POST --OHW — = OVERHEAD WIRE I® = BLUE FLAG 0 = DIAMETER S = PARKING METER = YELLOW FLAG ® = DRAINAGE MANHOLE RCV N = RECLAIMED WATER VALVE = ORANGE FLAG Eel = ELECTRIC BOX SVD4 = SANITARY VALVE = GREEN FLAG H© = ELECTRIC HAND HOLE ® = SET IRON ROD WITH CAP "LB. 6599" QA = AIR RELEASE VALVE EMS =ELECTRIC METER ® = SET NAIL AND DISK "L.B. 6599" F = FPL MANHOLE P,waL= ELECTRICAL PANEL = SIGN QU = UNKNOWN TYPE MANHOLE X 0.00 = EXISTING ELEVATION - SPIGOT Q = SANITARY MANHOLE 'T = FIBER OPTIC MARKER + = SPRINKLER VALVE p0 = STORMWATER DRAIAGE MANHOLE FO0 = FIBER OPTIC RISER .-¢-- = STREET SIGN F.O. = WATER SERVICE METER 1AULTO = FIBER OP11C VAULT ❑W YtQtpttb4bi}tt l7,7t 0.= GROUND LIGHT = CURB INLET �qq�w ELT o, I,! FLORIDA REGISTRATION #5556 ..1- 4- A I ' ENGINEERS Q SURVEYORS ENVIRONMENTAL 10250 VILLAGE PARKWAY UNIT 201 PORT ST. LUCIE, FL 34987 'R 772.462-2455 -,� www.edc-inc.com F.B.P.E. CERTIFICATE OF AUTHORIZATION 9935 L.B. CERTIFICATE OF AUTHORIZATION 8098 cl W 0 0 LL I— COD Ca W r Go ®> V �Wo Z V J uj CL � 0 U 3r LJi. = U 0Z, C) m �" M° Z L Lu _L uJ 0(D ® `Z I U) mO L.L. LJ. O 14, j LIJ U) 10250 VILLAGE PARKWAY UNIT 201 PORT ST. LUCIE, FL 34987 `��' 772-462-2455 I — . — -1 i SIGNATURE D TE: &IP Ja SETBACK 10. :FRONT 4 ?ID"ES �Q`T (1IVft SIDES R AR _ ehlG.J?- TECH. 0 7)I