HomeMy WebLinkAboutRevision-2103-0802 OFFICE USE ONLY: File COPY
DATE-FILED: PERMIT#2103-0802
REVISION FEE: RECEIPT#
PLANNING&DEVELOPMENT SERVICES
BUILDING&CODE REGULATION DIVISION ...
2300 VIRGINIA AVENUE RECEIVED
FORT PIERCE,FL 34982.5652
(772)462-1553 AUG 2 3 2021
APPLICATION FOR BUILDING PERMIT REVISIONS St huci Cfltttt4y
PROJECT INFORMATION pmitt+ng
LOCATION/SITE
ADDRESS:
Whippoorwill:Run-Condos at 2967-2973 Bent Pine Dr Fort Pierce,FL 34951
DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Replace existing skylights with new skylight lids
CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: CCC1326188 ST. LUCIE CO CERT.#: 27265
BUSINESS NAME: Atlantic Roofing of Vero Beach,lnc
QUALIFIERS NAME: William Lasky,Jr.
ADDRESS: 4310 45th St
CITY: Vero Beach STATE: FL ZIP: 32967
PHONE(DAYTIME): 772-492-8493 FAX: 772-257-5740
OWNER/BUILDER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME: ' FAX:
ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): K_
SLCCC: 9123109
Revised 06/30/17Ul
,ti
�6q 2-t q
Product Evaluation Report
V-1 J Jola- 059, Rev. 5 1 Project No. 420-0913 1 11/30/20 1 Page 1 of 3
Manufacturer Product Series, Model and/ iPly
? GlassSkylights'�912 Kennedy Skylights Curb Mounted G as 35294 Tower Way Non-Impact a I t
Sanford, FL 32773 g�
Code: Current Edition of the Florida Building Code including the 7th Edition(2020)Flo '
jQQMPLIANCE
�°p L� IE COUNT
Compliance Methods: Product Approval Rule 61G20-3.005(1)(a)—Certification Mark or is in
Product Installation Instructions:
• KENN0001, Rev. B,dated 12/6/17,signed and'sealed by Robert J.Amoruso, Kennedy Skylights"ICMG"
Curb Mounted Glass Skylight—LMI—HVHZ, Installation Anchorage Details
• KENN0003, Rev.C,dated 12/14/19,signed and sealed by Robert J.Amoruso, Kennedy Skylights"CMG"
Curb Mounted Glass Skylight-NI, Installation Anchorage Details
• KENN0005, Rev.C,dated 12/14/19,signed and sealed by Robert J.Amoruso, Kennedy Skylights"SFG4"
Curb Mounted Self Flashing Glass Skylight-NI, Installation Anchorage Details
Engineering Analysis£t Product Evaluation: The following engineering and/or rational analysis/calculations have been
performed.
• Anchorage and product verification have been substantiated by calculation(PTC Report.No.2058-1 and 2058-2)
prepared,signed and sealed by Robert J.Amoruso,P.E.in accordance with the current edition of the'Florida
Building Code.
• Design Pressure Evaluation/Product Evaluation
o Drawing No.KENN0001
■ Product Name/Series:"ICMG"Curb Mounted Glass Skylight—LMI
■ High Velocity Hurricane Zone(HVHZ):YES
■ Outside High Velocity Hurricane Zone(HVHZ):YES
■ Impact Resistant:YES
• Glazed laminated product using Kuraray Trosifol PVB Glass Interlayer by Kuraray
America,Inc.Current Kuraray America NOA can be found here.
■ National Certified Test Laboratory, Inc.Test Report No.NCTL-210-3041-1,2
■ Design Pressure
• +/-60 psf
• Margin of Safety=2 applied for positive and negative loading to Structural Design
Pressure per Sections 1504 and 1523 of the current edition of the FBC and MD FAQ
(http://www.miamidade.gov/building/products/skylights.-asp).
■ Performance and Testing Standards
• Test Report No.NCTL-210-3041-1,2
o TAS202-94
o TAS201-94
o TAS203-94
o Drawing No.KENN0003
■ Product Name/Series:"CMG"Curb Mounted Glass Skylight-NI
■ High Velocity Hurricane Zone(HVHZ):NO
■ Outside High Velocity Hurricane Zone(HVHZ):YES
■ Impact Resistant:NO
■ National Certified Test Laboratory,Inc.Test Report No.NCTL-210-3041-3A
■ Design Pressure
A• .MW PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775
��/L 321-690-1788 1 FBPE Certification of Authorization No. 25935
Product Evaluation Report
Rule 61G20-3 F.A.C. I Report No. 2059, Rev. 5 1 Project No. 420-0913 1 11/30/20 1 Page 2 of 3
• +/-95 psf outside HVHZ
• Margin of Safety=2 applied to Structural Design Pressure per Sections 1504 of the
current edition of the FBC.
■ Performance and Testing Standards
• Test Report No.NCTL-210-3041-3A
o AAMA/WDMA 1600/I.S.7-00,Voluntary Specification for Skylights
o Drawing No.KENN0005
■ Product Name/Series:"SFG4"Curb Mounted Self Flashing Glass Skylight-NI
■ High Velocity Hurricane Zone(HVHZ):NO
■ Outside High Velocity Hurricane Zone(HVHZ):YES
■ Impact Resistant:NO
■ National Certified Test Laboratory,Inc.Test Report No.NCTL-210-3012-1
■ Design Pressure
• +/-60 psf
• Margin of Safety=2 applied to Structural Design Pressure per Section 1504 of the
current edition of the FBC.
■ Performance and Testing Standards
• Test Report No.NCTL-210-3012-1
o AAMA/WDMA 1600/I.S.7-00,Voluntary Specification for Skylights
• Condensation Channel(Item No.3 on KENN0003 and Item No.8 on KENN0005)manufacturer has been changed to
Omega Plastics.The condensation channel is a non-structural component that collects condensation on the
skylight.It is an internal component offering no structural significance. Dimensionally and materially,the
condensation channel remains consistent with the original component used in testing and is therefore acceptable.
Performance Testing Standards:
• TAS 201-94-Impact Test Procedures
• TAS 202-94-Criteria for Testing Impact;Non-impact Resistant Building Envelope Components Using Uniform Static
Air Pressure
• TAS 203-94-Criteria for Testing Products Subject to Cyclic Wind Pressure Loading
• AAMA/WDMA 1600/I.S.7-00,Voluntary Specification for Skylights
Product Testing:
• NCTL-210-3041-1,2,dated 10/5/04,signed and sealed by Gerald J.Ferrara,P.E.,testing to TAS 201/202/203-94 for
"ICMG"Curb Mounted Glass Skylight
• NCTL-210-3041-3A,dated 10/5/04,signed and sealed by Gerald J.Ferrara,P.E.,testing to AAMA/WDMA 1600--
00/I.S.7-2000 for"CMG"Curb Mounted Glass Skylight
• NCTL-210-3012-1,dated 4/12/04,signed and sealed by Gerald J.Ferrara,P.E.,testing to AAMA/WDMA 1600-
00/I.S.7-2000 for"SFG4"Curb Mounted Self Flashing Glass Skylight
Material Certifications/Component Approvals:
• Laminated Glass Interlayer:See current Miami-Dade Notice of Acceptance(NOA)for component approval for
Kuraray Trosifol PVB Glass Interlayer by Kuraray America,Inc.used in this product.Kuraray America NOA can be
found here.
Limitations ft Conditions of Use:
• "ICMG"Curb Mounted Glass Skylight shown on KENN0001
o This product has been evaluated for use inside the HVHZ(High Velocity Hurricane Zone)
o This product is Impact Resistance.Therefore,a protective impact-rated device is not required.
PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775
r/L. 321-690-1788 1 FBPE Certification of Authorization No: 25935
Product Evaluation Report
Rule 61G20-3 F.A.C. I Report No. 2059, Rev. 5 1 Project No. 420-0913 1 11/30/20 1 Page 3 of 3
• "CMG'Curb Mounted Glass Skylight shown on KENN0003
o This product has not been evaluated for use inside the HVHZ(High Velocity Hurricane Zone)
o This product is not Impact Resistance.Therefore,a protective impact-rated device is required when used
in a wind-borne debris region.
• "SFG4"Curb Mounted Self Flashing Glass Skylight shown on KENN0005
o This product has not been evaluated for use inside the HVHZ(High Velocity Hurricane Zone)
o This product is not Impact Resistance.Therefore,a protective impact-rated device is required when used
in a wind-borne debris region.
• Refer to Product installation Instructions noted above for:
o Maximum allowable wind loads at related maximum allowable size(s).
o Overall dimensions and material/grade of main product components,accessories,etc.
o illustrated diagrams of the attachment of the product to the structure.
o Anchor type(s),size(s),substrate(s),embedment,edge distance,and spacing/locations.
• Site wind pressures shall be determined by a licensed professional engineer in accordance with the current edition
of the Florida Building Code(and/or ASCE 7 as referenced in the current edition of the Florida Building Code)for
components and cladding based on allowable stress design.
• Site conditions not covered in this product evaluation document are subject to additional engineering analysis by a
licensed professional engineer or registered architect as required by the authority having jurisdiction.
• Adequacy of the existing structural substrates as a main wind force resisting system capable of withstanding and
transferring applied product loads to the foundation is the responsibility of the licensed professional engineer or
registered architect acting as the design professional of record for the project of installation.
Certificate of Independence per Product Approval Digitally signed
E05�J8d^:
Rule 61G20-3.009 oe�0ga@�F., freoi
PTC Product Design Group,LLC and Robert J.Amoruso,P.E. .,7 e_C."., G E Pd e � Sao by Robert J
does not have,nor will acquire,any financial interest in the ,`> J•:Go'a
company manufacturing or distributing product(s)s covered 7°• No 39�5` 'a
P Y g gP ( ) Amoruso
by this Product Evaluation Report. PTC Product Design
Group,LLC and Robert J.Amoruso,P.E.do not have,nor '. Date.
:; OF
will acquire any financial interest in any other entity : 0•'• v •4f v`
f: '•f' N�e S o
involved in the approval process or testing of the .��r�``£;n Fit 0,,1 ��da 2020:11 :30
product(s)covered by this Product Evaluation Report.
17:36:26 -05'00'
Evaluated by:
Robert J. Amoruso, P.E.
FL PE License No. 49752
PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775
/O /L. 321-690-1788 1 FBPE Certification of Authorization No. 25935