HomeMy WebLinkAboutELECTRICAL UPGRADES1764 W Midway RoadFort Pierce, FL 34981SHEET
571 NW Mercantile Place
Suite 103
Port Saint Lucie, FL 34986
772-621-9494
772-621-9164 fax
bellwether.electric@gmail.com
EC13004122
E01
Drawing Date: 8/11/2021
Scale: 1/4"=1'-0"ELECTRICAL UPGRADESPower and
Lighting Plan
AH
DW
Cond
WH
Pump
SA
SA
SA
GFCI protection to be
installed for existing branch
circuits serving kitchen
countertop areas, exterior
receptacles and bathrooms
Replace
existing
breaker
panel with
new NEMA
3R panel
Bedroom
Bedroom Bathroom
Kitchen
Living Area
Walled Garden
Bath
New Electric Service
Equipment with breaker panel
Existing branch circuits to be
connected and evaluated for
safety and function and
repaired as needed.
FPL Point of Service
Existing
range
circuit to
remain
3/4" PVC
3-10
2-123/4" PVC
4-10
1/2" PVC
3-12
3/4" PVC
3-10
1/2" PVC
3-12
14/2
Romex
Dwelling has no attached
garage, no gas fueled
appliances, and no
fireplace. CO Detectors not
required
3/4" Conduit
3-10
New Hood
Outlet
12/2
Romex