Loading...
HomeMy WebLinkAboutELECTRICAL1764 W Midway RoadFort Pierce, FL 34981SHEET 571 NW Mercantile Place Suite 103 Port Saint Lucie, FL 34986 772-621-9494 772-621-9164 fax bellwether.electric@gmail.com EC13004122 E02 Drawing Date: 8/11/2021 Scale: N.T.S.ELECTRICAL UPGRADESRiser Diagram and Load Calculation Optional Service Load Calculation 220.80 NEC 2014 Service Load Calculation General Lighting Load 220.82(B)(1) 1188 square feet living area @ 3 VA = 3564 VA Total 3564 VA Minimum Number of Branch Circuits Required 3564 29.7 amps 29.7 2.0 2 circuits 29.7 1.5 2 circuits Small Appliance Load 220.82(B)(2) 2 Small appliance circuits @ 1500 VA = 3000 VA Total 3000 VA Laundry Load 220.82(B)(2) 1 Laundry Circuit @ 1500 VA = 1500 VA Total 1500 VA Appliances Fastened In Place (Other Than Cooking, Dryers, Heat, and AC) 220.82(B)(3&4) 1 1800 1800 VA 0 500 0 VA 0 1440 0 VA 0 960 0 VA 0 510 0 VA 1 4500 4500 VA 000VA 000VA 000VA 000VA Appliance Demand Load @ Name Plate Values 6300 VA Cooking Appliances 220.82(B)(3) 1 Cooking Appliance at Nameplate 12000 12000 VA 0 Cooking Appliance at Nameplate 8000 0 VA Total 12000 VA Electric Dryers 220.82(B)(3) 1 Dryer(s) At Nameplate = 6240 6240 VA Total 6240 VA Total Load Subject To Demand Factor 32604 Demand Factor 220.82(B) 1st 10000 VA @ 100%10000 VA Over 10000 VA @ 40%9042 VA Net Load 19042 VA Fixed Electric Space Heating 220.82(C ) 1 5 KW Heat Strips in A/H With Blower 5414 5414 VA 0 8 KW Heat Strips in A/H With Blower 8460 0 VA 0 10 KW Heat Strips in A/H With Blower 10506 0 VA Total 5414 VA x 65% 3519.1 VA Heat Pumps 220.82(C ) 0 1.5 Ton Heat Pump 1495 0 VA 1 2 Ton Heat Pump 2300 2300 VA 0 2.5 Ton Heat Pump 2392 0 VA 0 3 Ton Heat Pump 3565 0 VA 0 3.5 Ton Heat Pump 3864 0 VA 0 4 Ton Heat Pump 4600 0 VA 0 5 Ton Heat Pump 6026 0 VA Total 2300 VA Motors 220.50 and 430.24 0 1/2 HP 1127 0 VA 0 3/4 HP 1587 0 VA 0 1 HP 1840 0 VA 1 1‐1/2 HP 2300 2300 VA 0 2 HP 2760 0 VA 0 3 HP 3910 0 VA Total Motor Loads 2300 VA Largest Motor or Motor Combination Equipment x 25%575 VA Total 2875 VA Net Calculated Load 27736 VA For 120/240 Volt 3‐Wire Single Phase Service: 115.57 Amps / 120 volts = / 15 amps = / 20 amps = 1764 W Midway Road Fort Pierce, FL Range Hood 0 Microwave 120V Dishwasher Disposal Garage Door Operator Water Heater 0 0 0 0 0 0 0 0 0 Optional Service Load Calculation 220.80 NEC 2014 Feeder Load Calculation General Lighting Load 220.82(B)(1) 1188 square feet living area @ 3 VA = 3564 VA Total 3564 VA Minimum Number of Branch Circuits Required 3564 29.7 amps 29.7 2.0 2 circuits 29.7 1.5 2 circuits Small Appliance Load 220.82(B)(2) 2 Small appliance circuits @ 1500 VA = 3000 VA Total 3000 VA Laundry Load 220.82(B)(2) 0 Laundry Circuit @ 1500 VA = 0 VA Total 0 VA Appliances Fastened In Place (Other Than Cooking, Dryers, Heat, and AC) 220.82(B)(3&4) 1 1800 1800 VA 0 500 0 VA 0 1440 0 VA 0 960 0 VA 0 510 0 VA 0 4500 0 VA 000VA 000VA 000VA 000VA Appliance Demand Load @ Name Plate Values 1800 VA Cooking Appliances 220.82(B)(3) 1 Cooking Appliance at Nameplate 12000 12000 VA 0 Cooking Appliance at Nameplate 8000 0 VA Total 12000 VA Electric Dryers 220.82(B)(3) 0 Dryer(s) At Nameplate = 6240 0 VA Total 0 VA Total Load Subject To Demand Factor 20364 Demand Factor 220.82(B) 1st 10000 VA @ 100%10000 VA Over 10000 VA @ 40%4146 VA Net Load 14146 VA Fixed Electric Space Heating 220.82(C ) 0 5 KW Heat Strips in A/H With Blower 5414 0 VA 0 8 KW Heat Strips in A/H With Blower 8460 0 VA 0 10 KW Heat Strips in A/H With Blower 10506 0 VA Total 0 VA x 65% 0 VA Heat Pumps 220.82(C ) 0 1.5 Ton Heat Pump 1495 0 VA 0 2 Ton Heat Pump 2300 0 VA 0 2.5 Ton Heat Pump 2392 0 VA 0 3 Ton Heat Pump 3565 0 VA 0 3.5 Ton Heat Pump 3864 0 VA 0 4 Ton Heat Pump 4600 0 VA 0 5 Ton Heat Pump 6026 0 VA Total 0 VA Motors 220.50 and 430.24 0 1/2 HP 1127 0 VA 0 3/4 HP 1587 0 VA 0 1 HP 1840 0 VA 0 1‐1/2 HP 2300 0 VA 0 2 HP 2760 0 VA 0 3 HP 3910 0 VA Total Motor Loads 0VA Largest Motor or Motor Combination Equipment x 25%0 VA Total 0 VA Net Calculated Load 14146 VA For 120/240 Volt 3‐Wire Single Phase Service: 58.94 Amps / 120 volts = / 15 amps = / 20 amps = 1764 W Midway Road Fort Pierce, FL Range Hood 0 Microwave 120V Dishwasher Disposal Garage Door Operator Water Heater 0 0 0 0 0 0 0 0 0 Panel B Replace existing panel with New 125 Amp MLO NEMA 3R panel 1" PVC 3-6 1-8 60 Riser Diagram Panel A New 200 Amp Main Breaker NEMA 3R Panel 2" RMC 3-4/0 AL #4 bare SOL CU to two 5/8" x 8 ground rods and existing metal piping systems if any 2" PVC 2-4/0 AL New 200 Amp Meter Socket System Voltage: 120/240V Single Phase