HomeMy WebLinkAboutProject InformationIf A. • Load Short Form aatarg� Iuc (Rest of House) For: Pedro Carvalho Htg Clg Outside db (OF) 43 90 Inside db (°F) 70 75 Design TD (°F) 27 15 Daily range - L Inside humidity (%) 50 50 Moisture difference (grAb) 22 61 HEATING EQUIPMENT RI ref clency sting input Sting output nperature rise ual airflow flow factor tic pressure ace thermostat 100 EFF 7.5 kW 25455 Btuh 15 OF 1517 cfm 0.059 cfm/Btuh 0 in H2O M Rizzo NOV 1..3. 1010 Permitting Department St. Lucie County Infiltration Method Construction quality Fireplaces COOLING EQUIPMENT Make Goodman Mfg. Trade GOODMAN Cond GSX140481K" Simplified Semi -tight 0 Coil A(E,F)M614++TDR AHRI ref 201876848 Efficiency 11.7 EER, 15 SEER Sensible cooling 31850 Btuh Latent cooling 13650 Btuh Total cooling 45500 Btuh Actual airflow 1517 cfm Airflowfactor 0.036 cfmBtuh Static pressure 0 in H2O Load sensible heat ratio. 0.88 ROOM NAME Area (ft2) Htg load (Btuh) Cig load (Btuh) Htg AVF (cfm) CIgAVF (cfm) 'i Bed 3 182 2118 3981 124 142 diving area 2008 12806 20209 751 721 (Master Bed 275 3151 5403 185 193 Rooms 21 193 131 11 5 oom6 18 0 0 0 0 �aundry 51 1084 1247 64 45 Mast bath 162 1141 3586 67 128 oom9 25 570 338 33 12 en 139 1769 3166 104 113 Bath 1 77 497 374 29 13 lbed 192 2531 4063 148 145 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wright5oft' FZigttSrdteC-Universal 2019 19.0.20 RSU0290B Wy Doamer ts\Heat loadslCarvalholCarvalho.n p Calc = M,1B Front Door faces: N 2020-Oct 22 16:18:17 Page 1 t (Rest of House) 3149 25862 42498 1517 1517 Other equip loads 0 0 Equip. @ 0.95 RSM 40373 Latent cooling 5732 TOTALS 1 3149 I 25862 ' 46104 ' 1517 1 1517 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsaft- Right-Sute&Uriversal201919.0.20RSU02908 sWyDoamentsWeatloadslCarvalho\Carvaftnp Calc=MJB Front Door faces: N 2020-Oct 22 16:1 B:17 Page 2 ALoad Short Form ahu Z For: Pedro Carvalho Htg CIg Outside db (°F) 43 90 Method Inside db (°F) 70 75 Construction quality Design TD (°F) 27 15 Fireplaces Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 22 61 Job: Carvalho Da 21, 2020 By: Chri pher T. Rizzo z.-.0 Infiltration Simplified Semi -tight 0 HEATING EQUIPMENT COOLING EQUIPMENT ake Make Goodman Mfg. rade Trade GOODMAN odel Cond GSX140251L` RI ref Coil A(E,F)M304++TDR AHRI ref 201876825 Efficiency 100 EFF Efficiency 12.0 EER, 15 SEER eating input 3.4 kW Sensible cooling 16100 Btuh eating output 11448 Btuh Latent cooling 6900 Btuh emperature rise 14 °F Total cooling 23000 Btuh dual airflow 767 cfm Actual airflow 767 cfm rflowfactor 0.061 cfm/Btuh Airflowfactor 0.040 cfm/Btuh tatic pressure 0 in H2O Static pressure 0 in H2O pace thermostat Load sensible heat ratio 0.84 ROOM NAME Area Htg load Clg load Htg AVF CIgAVF (fF) (Btuh) (Btuh) (cfm) (cfm) ovie Rm 1120 11515 18432 700 739 th 3 31 1101 683 67 27 et bar 42 0 0 0 0 hu 2 1193 12617 19114 767 767 ther equip loads 0 0 Equip. @ 0.95 RSM 18159 tent cooling 3552 OTALS 1193 12617 21711 767 767 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoftN Right SLj*QD-Jniversa12019 19.0.20 RSU02908 AC3C-K ...s\My DoamentsWeat IoadMCarvalho\Garvafm.rup Calc = MJ8 Front Door Faces: N 2020-od 22 16:18:17 Page 3 d :• Project Summary (Rest of House) AfC� A a*age Fine; For: Pedro Carvalho Notes: Weather: Vero Beach, FL, US Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 21623 Btuh Ducts 4239 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 25862 Btuh Infiltration Method Construction quality Fireplaces Simplified Semi -tight 0 Heating Cooling Area (fl 3149 3149 Volume (ft') 34560 34560 Air changes/hour 0.16 0.08 Equiv AVF (cfm) 92 48 Heating Equipment Summary Make Trade Model AHRI ref Efficiency 100 EFF Heating input 7.5 kW Heating output 25455 Btuh Temperature rise 15 OF Actual airflow 1517 cfm Airflowfactor 0.059 cfm/Btuh Static pressure 0 in H2O Space thermostat AJO Ca Iho Chris pher T. :J/'lL�LA Z.o Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 grAb Sensible Cooling Equipment Load Sizing Structure 35660 Btuh Ducts 6838 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 40373 Btuh Latent Cooling Equipment Load Sizing Structure 4215 Btuh Ducts 1517 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5732 Btuh Equipment Total Load (Sen+Lat) 46104 Btuh Req. total capacity at 0.70 SHR 4.8 ton Cooling Equipment Summary Make Goodman Mfg Trade GOODMAN Cond GSX140481 K" Coil A(E,F)M614++TDR AHRI ref 201876848 Efficiency 11.7 EER,15 SEER Sensible cooling 31850 Btuh Latent cooling 13650 Btuh Total cooling 45500 Btuh Actual airflow 1517 cfm Air flow factor 0.036 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.88 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fk wrigtstsoft 2020-Oct-2216:18:17 Right-SLAegUniversal 201919.0.20 RSU02908 Page 1 s1MyDoc=arasWeatloadslCarvalholCarvaft.rup Calc=MJB FrontDoorfaces: N Project Summary ahu 2 fnc;. For: Pedro Carvalho Notes: Weather: Vero Beach, FL, US Winter Design Conditions Outside db 43 OF Inside db 70 OF Design TD 27 OF Heating Summary Structure 10368 Btuh Ducts 2249 Btuh Central vent (0 cfm) D Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 12617 Btuh Infiltration Method Construction quality Fireplaces Simplified Semi -tight 0 Heatingg Cooling Area (fF) 1193 1193 Volume (fP) 11858 11858 Air changes/hour 0.28 0.15 Equiv AVF (cfm) 55 29 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating Input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat 100 EFF 3.4 kW 11448 Btuh 14 OF 767 cfm 0.061 cIm/Btuh 0 in H2O 2020 Sher T. Rizzo T L& JZzl .a o Z o Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity L 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 15560 Btuh Ducts 3554 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 18159 Btuh Latent Cooling Equipment Load Sizing Structure 2817 Btuh Ducts 735 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 3552 Btuh Equipment Total Load (Sen+Lat) 21711 Btuh Req. total capacity at 0.70 SHR 2.2 ton Cooling Equipment Summary Make Goodman Mfg. Trade GOODMAN Cond GSX140251L* Coil A E,F M304++TDR AHRI ref 201876825 Efficiency 12.0 EER,15 SEER Sensible cooling 16100 Btuh Latent cooling 6900 Btuh Total cooling 23000 Btuh Actual airflow 767 cf n Air flow factor 0.040 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -4- wrigF%tsoft- 2020-Oct 22 16:18:17 1..1 ,,,,,, , ,,,,,,,,,--m,„ Rigft-& e®UNversal 2019 19.0.20 RSU029DB Page 2 sWlyDocunertslHeatloadsIGarvalhoiCarval:o.rup CaIc=M,1B Front Door faces: N