Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 ; FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Prussing Residence Builder Name: Street: 18103 Bridle Way Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL, 34987 Permit Number: Owner: Ryan & Christina Prussing Jurisdiction: S. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall TypeV048.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1792.00 ftz b. Frame- Wood, Adjacent R=11.0 256.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 11. Ceiling Types (2511.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2511.00 ft2 6. Conditioned floor area above grade (W) 2511 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(317.2 sqft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 90 a. U-Factor: Sgl, U=0.65 317.22 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 13. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 46.5 SEER:16.00 c. U-Factor: N/A ft2 SHGC: Area Weighted Average Overhang Depth: 6.006 ft. 14. Heating systems a. Electric Strip Heat kBtu/hr Efficiency 34.0 COP:1.00 Area Weighted Average SHGC: 0.250 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2511.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 2511.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits CF, Pstat Total Proposed Modified Loads: 70.25 PASS Glass/Floor Area: 0.126 Total Baseline Loads: 71.10 I hereby certify that the plans and specifications covered by Review of the plans and 4 TEi>r STRr this calculation are in compliance with the Florida Energy Code. specifications covered by this=="0� calculation indicates compliance Florida Energy Code.TOO r�`'>,. '�' ; _ - Na with the is PREPARED BY: Before construction completed ... DATE: 4-6-202'I this building will be inspected for compliance with Section 553.908 I hereby certify that uildin s ned, is in compliance Florida Statutes. SOD with the Florida E rgy Co LVE OWNER/AGE T: BUILDING OFFICIAL: DATE: 74 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2). F 1LE Copy 4/5/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Prussing Residence Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2511 Lot # Owner Name: Ryan & Christina Prussing Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 18103 Bridle Way Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: S. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Detached FL, 34987 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2511 20088 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 WIC 4 36 288 No 0 1 Yes Yes Yes 2 Bath 3 76 608 No 0 1 Yes Yes Yes 3 Bedroom 4 182 1456 No 2 1 1 Yes Yes Yes 4 Hall 44 352 No 0 1 Yes Yes Yes 5 Bedroom 3 208 1664 No 2 1 1 Yes Yes Yes 6 Bath 2 81 648 No 0 1 Yes Yes Yes 7 Bedroom 2 181 1448 No 0 1 1 Yes Yes Yes 8 Kitchen 285 2280 Yes 2 1 No Yes Yes 9 Hall 84 672 No 0 1 No Yes Yes 10 Dining 140 1120 No 0 1 Yes Yes Yes 11 Living Room 345 2760 No 2 1 Yes Yes Yes 12 Pantry 60 480 No 0 1 No Yes Yes 13 Laundry 60 480 No 0 1 Yes Yes Yes 14 Foyer 114 912 No 0 1 Yes Yes Yes 15 Master Bedroom 327 2616 No 2 1 1 Yes Yes Yes 16 WIC 2 54 432 No 0 1 Yes Yes Yes 17 WIC 1 42 336 No 0 1 No Yes Yes 18 Master Bath 168 1344 No 0 1 Yes Yes Yes 19 Toilet 24 192 No 0 1 Yes Yes Yes 4/5/2021 2:36 PM I EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 C:nonn onnr_OnOn IAIOI IT CI IMMARY CI4FCKI__IRT REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio WIC 4 12 ft 36 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulatio Bath 3 20 ft 76 T ---- 1 0 0 3 Slab -On -Grade Edge Insulatio Bedroom 4 14 ft 182 ft2 ---_ 1 0 0 4 Slab -On -Grade Edge Insulatio Hall 1 1 ft 44 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulatio Bedroom 3 13 ft 208 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulatio Bath 2 9 ft 81 ft2 _-_- 1 0 0 7 Slab -On -Grade Edge Insulatio Bedroom 2 lift 181 ft2 — 1 0 0 8 Slab -On -Grade Edge Insulatio Kitchen 1 ft 285 T _-__ 1 0 0 9 Slab -On -Grade Edge Insulatio Hall 2 1 ft 84 ft2 -___ 1 0 0 10SIab-On-Grade Edge Insulatio Dining 24 ft 140 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulatio Living Room 15 ft 345 T -_-- 1 0 0 12SIab-On-Grade Edge Insulatio Pantry 1 ft 60 T ---- 1 0 0 13SIab-On-Grade Edge Insulatio Laundry loft 60 ft2 ---- 1 0 0 14SIab-On-Grade Edge Insulatio Foyer 15 ft 114 T ___- 1 0 0 15SIab-On-Grade Edge Insulatio Master Bedroom 34 ft 327 ft2 ---- 1 0 0 16SIab-On-Grade Edge Insulatio WIC 2 9 ft 54 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulatio WIC 1 1 ft 42 ft2 _--- 1 0 0 18SIab-On-Grade Edge Insulatio Master Bath 27 ft 168 T _--- 1 0 0 19SIab-On-Grade Edge Insulatio Toilet loft 24 ft2 ---- 1 0 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Ban- Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2720 ft2 524 ft2 Medium N 0.6 No 0.9 No 0 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2511 ft2 N N 4/5/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) WIC 4 30 Batt 36 ft2 0.1 Wood 2 Under Attic (Vented) Bath 3 30 Batt 76 ft2 0.1 Wood 3 Under Attic (Vented) Bedroom 4 30 Batt 182 ft2 0.1 Wood 4 Under Attic (Vented) Hall 1 30 Batt 44 ft2 0.1 Wood 5 Under Attic (Vented) Bedroom 3 30 Batt 208 ft2 0.1 Wood 6 Under Attic (Vented) Bath 2 30 Batt 81 ft2 0.1 Wood 7 Under Attic (Vented) Bedroom 2 30 Batt 181 ft2 0.1 Wood 8 Under Attic (Vented) Kitchen 30 Batt 285 ft2 0.1 Wood 9 Under Attic (Vented) Hall 2 30 Batt 84 ft2 0.1 Wood 10 Under Attic (Vented) Dining 30 Batt 140 ft2 0.1 Wood 11 Under Attic (Vented) Living Room 30 Batt 345 ft2 0.1 Wood 12 Under Attic (Vented) Pantry 30 Batt 60 ft2 0.1 Wood 13 Under Attic (Vented) Laundry 30 Batt 60 ft2 0.1 Wood 14 Under Attic (Vented) Foyer 30 Batt 114 ft2 0.1 Wood 15 Under Attic (Vented) Master Bedroom 30 Batt 327 ft2 0.1 Wood 16 Under Attic (Vented) WIC 2 30 Batt 54 ft2 0.1 Wood 17 Under Attic (Vented) WIC 1 30 Batt 42 ft2 0.1 Wood 18 Under Attic (Vented) Master Bath 30 Batt 168 ft2 0.1 Wood 19 Under Attic (Vented) Toilet 30 Batt 24 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space tea1 E Exterior Concrete Block - Int Insul WIC 4 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 2 S Exterior Concrete Block - Int Insul WIC 4 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 3 S Exterior Concrete Block - Int Insul Bath 3 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 4 W Exterior Concrete Block - Int Insul Bath 3 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 5 E Exterior Concrete Block - Int InsuBedroom 4 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 6 W Exterior Concrete Block - Int Insul Hall 1 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 7 E Exterior Concrete Block - Int InsuBedroom 3 4.1 13 0 8 0 104.0 ft2 0 0 0.4 0 8 E Exterior Concrete Block - Int Insul Bath 2 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 9 E Exterior Concrete Block - Int InsuBedroom 2 4.1 11 0 8 0 88.0 ft2 0 0 0.4 0 _ 10 S Exterior Concrete Block - Int Insul Dining 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 11 W Exterior Concrete Block - Int Insul Dining 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 12 S Exterior Concrete Block - Int Insilliving Room 4.1 15 0 8 0 120.0 ft2 0 0 0.4 0 _ 13 N Exterior Concrete Block - Int Insul Laundry 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 14 N Exterior Concrete Block - Int Insul Foyer 4.1 15 0 8 0 120.0 ft2 0 0 0.4 0 15 S Exterior Concrete Block - Int InsMaster Bedro 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 16 W Exterior Concrete Block - Int InsMaster Sedro 4.1 18 0 8 0 144.0 ft2 0 0 0.4 0 17 W Exterior Concrete Block - Int Insul WIC 2 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 18 N Exterior Concrete Block - Int InsLMaster Bath 4.1 12 0 8 0 96.0 ft2 0 0 0.4 0 19 E Exterior Concrete Block - Int InstlVllaster Bath 4.1 9 0 8 0 72.0 ft2 0 0 0.4 0 20 W Exterior Concrete Block - Int InsWaster Bath 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 21 N Exterior Concrete Block - Int Insul Toilet 4.1 4 0 8 0 32.0 ft2 0 0 0.4 0 4/5/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent SpaceEt Cavity Width 113 Height FtArea Sheathing Framing Solar Below AhSor o _22 W Exterior Concrete Block - Int Insul Toilet 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _23 N Garage Frame - Wood Bedroom 2 11 14 8 112.0 ft2 0.23 0.4 0 _24 W Garage Frame - Wood Bedroom 2 11 2 8 16.0 ft2 0.23 0.4 0 _25 N Garage Frame - Wood Bedroom 2 11 3 8 24.0 ft2 0.23 0.4 0 _ 26 W Garage Frame - Wood Bedroom 2 11 5 8 40.0 ftz 0.23 0.4 0 _27 N Garage Frame - Wood Hall 2 11 4 8 32.0 ft2 0.23 0.4 0 _28 E Garage Frame - Wood Laundry 11 4 8 32.0 ft2 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Wood Bath 3 None .39 2 10 6 10 19.4 ft2 2 N Insulated Foyer None .39 6 a 48 ft2 3 N Insulated Hall 2 None .39 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 3 Metal Low-E Single Yes 0.65 0.25 Y 3.1 ft2 1 ft 7 in 1 ft 4 in None None 2 E 5 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 1 ft 7 in 1 ft 4 in None None 3 E 7 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 1 ft 7 in 1 ft 4 in None None 4 E 8 Metal Low-E Single Yes 0.65 0.25 Y 6.0 ft2' 1 ft 7 in 1 ft 4 in None None 5 E 9 Metal Low E Single Yes 0.65 0.25 Y 15.0 ft2 1 ft 7 in 1 ft 4 in None None 6 S 10 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 1 ft 7 in 1 ft 4 in None None 7 W 11 Metal Low-E Single Yes 0.65 0.25 Y 48.0 ft2 4 ft 0 in 1 ft 4 in None None 8 S 12 Metal Low-E Single Yes 0.65 0.25 Y 96.0 ft2 10 ft 0 in 1 ft 4 in None None 9 N 13 Metal Low-E Single Yes 0.66 0.25 Y 9.0 ft2 6 ft 0 in 1 ft 4 in None None 10 N 14 Metal Low-E Single Yes 0.65 0.25 Y 8.0 ft2 6 ft 0 in 1 ft 4 in None None 11 S 15 Metal Low-E Single Yes 0.65 0.25 Y 48.0 ft2 10 ft 0 in 1 ft 4 in None None 12 W 16 Metal Low-E Single Yes 0.65 0.25 Y 20.0 ft2 1 ft 7 in 1 ft 4 In None None 13 N 18 Metal Low-E Single Yes 0.65 0.25 Y 4.1 ft2 1 ft 7 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 567 ft2 567 ft2 32 ft 8 ft 11 4/5/2021 2:36 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000305 2008.8 110.21 206.9 .1083 6 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 46.5 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 DUCTS — Supply — # Location R-Value Area — Return --- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 90 ftZ Attic 20 ft' Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y CoolingH Jan [[ ]] Feb Mar HeatinJan [X] Feb Mar Vent in Jan [ l Feb Mar Ceiling Fans: [ ] Apr [ ] May [X� Jun [X] Jul [X] AugX] Se [ ] [ ] Apr € ] May E ] Jun [ ] Jul [ ] Aui ] Sep [ ] [X] Apr ] May ] Jun [ ] Jul [ l Aug [ ] Se [X] Oct r ] Nov Oct [X] Nov Oct [X] Nov Dec Dec Dec 4/5/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 WIC 4 Default(8 lbs/sq.ft. ft2 ft 0.3 Bath 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(B Ibs/sq.ft. ft2 ft 0.3 Hall 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 lbs/sq.ft. ft2 ft 0.3 Living Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 WIC 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Toilet 4/5/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Softwar6 Page 7 of 7 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Prussing Residence Builder Name: Street: 18103 Bridle Way Permit Office: St. Lucie County City, State, Zip: Fort Pierce , FL , 34987 Permit Number: Y Owner: Ryan & Christina Prussing Jurisdiction: S. Lucie County W Design Location: FL, Fort Pierce C) COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier, not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be Installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity Insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation Installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind nmn'no and wirina. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs, be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover glates and walls or ceil*nos. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 4/5/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1