HomeMy WebLinkAboutEnergy CodeFORM R405-2020 ;
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Prussing Residence
Builder Name:
Street: 18103 Bridle Way
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL, 34987
Permit Number:
Owner: Ryan & Christina Prussing
Jurisdiction: S. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall TypeV048.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1792.00 ftz
b. Frame- Wood, Adjacent
R=11.0 256.00 ft
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
11. Ceiling Types (2511.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2511.00 ft2
6. Conditioned floor area above grade (W) 2511
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(317.2 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ft2
6 90
a. U-Factor: Sgl, U=0.65 317.22 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
46.5 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 6.006 ft.
14. Heating systems
a. Electric Strip Heat
kBtu/hr Efficiency
34.0 COP:1.00
Area Weighted Average SHGC: 0.250
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (2511.0 sqft.) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 2511.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
CF, Pstat
Total Proposed Modified Loads: 70.25
PASS
Glass/Floor Area: 0.126
Total Baseline Loads: 71.10
I hereby certify that the plans and specifications covered by
Review of the plans and
4 TEi>r STRr
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this=="0�
calculation indicates compliance
Florida Energy Code.TOO
r�`'>,. '�' ; _ - Na
with the
is
PREPARED BY:
Before construction completed
...
DATE: 4-6-202'I
this building will be inspected for
compliance with Section 553.908
I hereby certify that uildin s ned, is in compliance
Florida Statutes.
SOD
with the Florida E rgy Co
LVE
OWNER/AGE T:
BUILDING OFFICIAL:
DATE: 74
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
F
1LE Copy
4/5/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Prussing Residence
Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2511
Lot #
Owner Name:
Ryan & Christina Prussing
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
18103 Bridle Way
Permit Office:
St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
S. Lucie County
Whole House Fan: No
City, State,
Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34987
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
heating
Design Daily Temp
Design
Location
TMY Site
97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2511
20088
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
WIC 4
36
288 No
0
1
Yes
Yes
Yes
2
Bath 3
76
608 No
0
1
Yes
Yes
Yes
3
Bedroom 4
182
1456 No
2
1
1
Yes
Yes
Yes
4
Hall
44
352 No
0
1
Yes
Yes
Yes
5
Bedroom 3
208
1664 No
2
1
1
Yes
Yes
Yes
6
Bath 2
81
648 No
0
1
Yes
Yes
Yes
7
Bedroom 2
181
1448 No
0
1
1
Yes
Yes
Yes
8
Kitchen
285
2280 Yes
2
1
No
Yes
Yes
9
Hall
84
672 No
0
1
No
Yes
Yes
10
Dining
140
1120 No
0
1
Yes
Yes
Yes
11
Living Room
345
2760 No
2
1
Yes
Yes
Yes
12
Pantry
60
480 No
0
1
No
Yes
Yes
13
Laundry
60
480 No
0
1
Yes
Yes
Yes
14
Foyer
114
912 No
0
1
Yes
Yes
Yes
15
Master Bedroom
327
2616 No
2
1
1
Yes
Yes
Yes
16
WIC 2
54
432 No
0
1
Yes
Yes
Yes
17
WIC 1
42
336 No
0
1
No
Yes
Yes
18
Master Bath
168
1344 No
0
1
Yes
Yes
Yes
19
Toilet
24
192 No
0
1
Yes
Yes
Yes
4/5/2021 2:36 PM I EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7
C:nonn onnr_OnOn IAIOI IT CI IMMARY CI4FCKI__IRT REPORT
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
WIC 4
12 ft
36 ft2
----
1
0
0
2 Slab -On -Grade Edge Insulatio
Bath 3
20 ft
76 T
----
1
0
0
3 Slab -On -Grade Edge Insulatio
Bedroom 4
14 ft
182 ft2
---_
1
0
0
4 Slab -On -Grade Edge Insulatio
Hall 1
1 ft
44 ft2
----
1
0
0
5 Slab -On -Grade Edge Insulatio
Bedroom 3
13 ft
208 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulatio
Bath 2
9 ft
81 ft2
_-_-
1
0
0
7 Slab -On -Grade Edge Insulatio
Bedroom 2
lift
181 ft2
—
1
0
0
8 Slab -On -Grade Edge Insulatio
Kitchen
1 ft
285 T
_-__
1
0
0
9 Slab -On -Grade Edge Insulatio
Hall 2
1 ft
84 ft2
-___
1
0
0
10SIab-On-Grade Edge Insulatio
Dining
24 ft
140 ft2
----
1
0
0
11SIab-On-Grade Edge Insulatio
Living Room
15 ft
345 T
-_--
1
0
0
12SIab-On-Grade Edge Insulatio
Pantry
1 ft
60 T
----
1
0
0
13SIab-On-Grade Edge Insulatio
Laundry
loft
60 ft2
----
1
0
0
14SIab-On-Grade Edge Insulatio
Foyer
15 ft
114 T
___-
1
0
0
15SIab-On-Grade Edge Insulatio
Master Bedroom 34 ft
327 ft2
----
1
0
0
16SIab-On-Grade Edge Insulatio
WIC 2
9 ft
54 ft2
----
1
0
0
17SIab-On-Grade Edge Insulatio
WIC 1
1 ft
42 ft2
_---
1
0
0
18SIab-On-Grade Edge Insulatio
Master Bath
27 ft
168 T
_---
1
0
0
19SIab-On-Grade Edge Insulatio
Toilet
loft
24 ft2
----
1
0
0
ROOF
/
Roof
Gable Roof
Red
Solar SA Emitt
Emitt
Deck
Pitch
v # Type Materials
Area
Area Color
Ban-
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed Composition shingles 2720 ft2
524 ft2 Medium
N
0.6 No 0.9
No
0
22.62
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Vented
150
2511 ft2
N N
4/5/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) WIC 4
30
Batt
36 ft2
0.1
Wood
2
Under Attic (Vented) Bath 3
30
Batt
76 ft2
0.1
Wood
3
Under Attic (Vented) Bedroom 4
30
Batt
182 ft2
0.1
Wood
4
Under Attic (Vented) Hall 1
30
Batt
44 ft2
0.1
Wood
5
Under Attic (Vented) Bedroom 3
30
Batt
208 ft2
0.1
Wood
6
Under Attic (Vented) Bath 2
30
Batt
81 ft2
0.1
Wood
7
Under Attic (Vented) Bedroom 2
30
Batt
181 ft2
0.1
Wood
8
Under Attic (Vented) Kitchen
30
Batt
285 ft2
0.1
Wood
9
Under Attic (Vented) Hall 2
30
Batt
84 ft2
0.1
Wood
10
Under Attic (Vented) Dining
30
Batt
140 ft2
0.1
Wood
11
Under Attic (Vented) Living Room
30
Batt
345 ft2
0.1
Wood
12
Under Attic (Vented) Pantry
30
Batt
60 ft2
0.1
Wood
13
Under Attic (Vented) Laundry
30
Batt
60 ft2
0.1
Wood
14
Under Attic (Vented) Foyer
30
Batt
114 ft2
0.1
Wood
15
Under Attic (Vented) Master Bedroom
30
Batt
327 ft2
0.1
Wood
16
Under Attic (Vented) WIC 2
30
Batt
54 ft2
0.1
Wood
17
Under Attic (Vented) WIC 1
30
Batt
42 ft2
0.1
Wood
18
Under Attic (Vented) Master Bath
30
Batt
168 ft2
0.1
Wood
19
Under Attic (Vented) Toilet
30
Batt
24 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
Space
tea1
E
Exterior Concrete Block - Int Insul WIC 4
4.1
6
0 8
0
48.0 ft2
0
0
0.4
0
2
S
Exterior Concrete Block - Int Insul WIC 4
4.1
6
0 8
0
48.0 ft2
0
0
0.4
0
3
S
Exterior Concrete Block - Int Insul Bath 3
4.1
11
0 8
0
88.0 ft2
0
0
0.4
0
4
W
Exterior Concrete Block - Int Insul Bath 3
4.1
9
0 8
0
72.0 ft2
0
0
0.4
0
5
E
Exterior Concrete Block - Int InsuBedroom 4
4.1
14
0 8
0
112.0 ft2
0
0
0.4
0
6
W
Exterior Concrete Block - Int Insul Hall 1
4.1
1
0 8
0
8.0 ft2
0
0
0.4
0
7
E
Exterior Concrete Block - Int InsuBedroom 3
4.1
13
0 8
0
104.0 ft2
0
0
0.4
0
8
E
Exterior Concrete Block - Int Insul Bath 2
4.1
9
0 8
0
72.0 ft2
0
0
0.4
0
9
E
Exterior Concrete Block - Int InsuBedroom 2
4.1
11
0 8
0
88.0 ft2
0
0
0.4
0
_ 10
S
Exterior Concrete Block - Int Insul Dining
4.1
14
0 8
0
112.0 ft2
0
0
0.4
0
11
W
Exterior Concrete Block - Int Insul Dining
4.1
10
0 8
0
80.0 ft2
0
0
0.4
0
12
S
Exterior Concrete Block - Int Insilliving Room
4.1
15
0 8
0
120.0 ft2
0
0
0.4
0
_ 13
N
Exterior Concrete Block - Int Insul Laundry
4.1
10
0 8
0
80.0 ft2
0
0
0.4
0
14
N
Exterior Concrete Block - Int Insul Foyer
4.1
15
0 8
0
120.0 ft2
0
0
0.4
0
15
S
Exterior Concrete Block - Int InsMaster Bedro
4.1
16
0 8
0
128.0 ft2
0
0
0.4
0
16
W
Exterior Concrete Block - Int InsMaster Sedro
4.1
18
0 8
0
144.0 ft2
0
0
0.4
0
17
W
Exterior Concrete Block - Int Insul WIC 2
4.1
9
0 8
0
72.0 ft2
0
0
0.4
0
18
N
Exterior Concrete Block - Int InsLMaster Bath
4.1
12
0 8
0
96.0 ft2
0
0
0.4
0
19
E
Exterior Concrete Block - Int InstlVllaster Bath
4.1
9
0 8
0
72.0 ft2
0
0
0.4
0
20
W
Exterior Concrete Block - Int InsWaster Bath
4.1
6
0 8
0
48.0 ft2
0
0
0.4
0
21
N
Exterior Concrete Block - Int Insul Toilet
4.1
4
0 8
0
32.0 ft2
0
0
0.4
0
4/5/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
SpaceEt
Cavity Width
113
Height
FtArea
Sheathing Framing
Solar Below
AhSor o
_22
W
Exterior
Concrete Block - Int
Insul Toilet
4.1 6
0
8 0
48.0 ft2
0
0
0.4
0
_23
N
Garage
Frame
- Wood
Bedroom 2
11 14
8
112.0 ft2
0.23
0.4
0
_24
W
Garage
Frame
- Wood
Bedroom 2
11 2
8
16.0 ft2
0.23
0.4
0
_25
N
Garage
Frame - Wood
Bedroom 2
11 3
8
24.0 ft2
0.23
0.4
0
_ 26
W
Garage
Frame
- Wood
Bedroom 2
11 5
8
40.0 ftz
0.23
0.4
0
_27
N
Garage
Frame
- Wood
Hall 2
11 4
8
32.0 ft2
0.23
0.4
0
_28
E
Garage
Frame - Wood
Laundry
11 4
8
32.0 ft2
0.23
0.4
0
DOORS
#
Ornt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
W
Wood
Bath 3
None
.39
2
10
6 10
19.4 ft2
2
N
Insulated
Foyer
None
.39
6
a
48 ft2
3
N
Insulated
Hall 2
None
.39
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame
Panes
NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
S
3
Metal
Low-E Single
Yes
0.65 0.25
Y
3.1 ft2
1 ft 7 in
1 ft 4 in
None
None
2
E
5
Metal
Low-E Single
Yes
0.65 0.25
Y
15.0 ft2
1 ft 7 in
1 ft 4 in
None
None
3
E
7
Metal
Low-E Single
Yes
0.65 0.25
Y
15.0 ft2
1 ft 7 in
1 ft 4 in
None
None
4
E
8
Metal
Low-E Single
Yes
0.65 0.25
Y
6.0 ft2'
1 ft 7 in
1 ft 4 in
None
None
5
E
9
Metal
Low E Single
Yes
0.65 0.25
Y
15.0 ft2
1 ft 7 in
1 ft 4 in
None
None
6
S
10
Metal
Low-E Single
Yes
0.65 0.25
Y
30.0 ft2
1 ft 7 in
1 ft 4 in
None
None
7
W
11
Metal
Low-E Single
Yes
0.65 0.25
Y
48.0 ft2
4 ft 0 in
1 ft 4 in
None
None
8
S
12
Metal
Low-E Single
Yes
0.65 0.25
Y
96.0 ft2
10 ft 0 in
1 ft 4 in
None
None
9
N
13
Metal
Low-E Single
Yes
0.66 0.25
Y
9.0 ft2
6 ft 0 in
1 ft 4 in
None
None
10
N
14
Metal
Low-E Single
Yes
0.65 0.25
Y
8.0 ft2
6 ft 0 in
1 ft 4 in
None
None
11
S
15
Metal
Low-E Single
Yes
0.65 0.25
Y
48.0 ft2
10 ft 0 in
1 ft 4 in
None
None
12
W
16
Metal
Low-E Single
Yes
0.65 0.25
Y
20.0 ft2
1 ft 7 in
1 ft 4 In
None
None
13
N
18
Metal
Low-E Single
Yes
0.65 0.25
Y
4.1 ft2
1 ft 7 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
567 ft2
567 ft2
32 ft
8 ft
11
4/5/2021 2:36 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000305
2008.8 110.21 206.9 .1083
6
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity
Block
Ducts
1 Electric Strip Heat/
None
COP:1 34 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 16 46.5 kBtu/hr cfm
0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric None
Garage
0.95 50 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
DUCTS
— Supply —
# Location R-Value Area
— Return --- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT
QN RLF
HVAC #
Heat Cool
1 Attic 6 90 ftZ
Attic
20 ft' Default Leakage Garage (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingH Jan [[ ]] Feb Mar
HeatinJan [X] Feb Mar
Vent in Jan [ l Feb Mar
Ceiling Fans:
[ ] Apr [ ] May [X� Jun [X] Jul [X] AugX] Se [ ]
[ ] Apr € ] May E ] Jun [ ] Jul [ ] Aui ] Sep [ ]
[X] Apr ] May ] Jun [ ] Jul [ l Aug [ ] Se [X]
Oct r ] Nov
Oct [X] Nov
Oct [X] Nov
Dec
Dec
Dec
4/5/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating(WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
WIC 4
Default(8 lbs/sq.ft.
ft2
ft
0.3
Bath 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 4
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Hall 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 3
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bath 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Bedroom 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Kitchen
Default(B Ibs/sq.ft.
ft2
ft
0.3
Hall 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Dining
Default(8 lbs/sq.ft.
ft2
ft
0.3
Living Room
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Pantry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Laundry
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Foyer
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master
Bedroom
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC 1
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Master Bath
Default(8 Ibs/sq.ft.
ft2
ft
0.3
Toilet
4/5/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Softwar6 Page 7 of 7
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Prussing Residence Builder Name:
Street: 18103 Bridle Way Permit Office: St. Lucie County
City, State, Zip: Fort Pierce , FL , 34987 Permit Number:
Y
Owner: Ryan & Christina Prussing Jurisdiction: S. Lucie County
W
Design Location: FL, Fort Pierce
C)
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier,
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be Installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity Insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation Installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace wall
.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind nmn'no and wirina.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs,
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover glates and walls or ceil*nos.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/5/2021 2:36 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1