Loading...
HomeMy WebLinkAboutBuilding Plans2605 3AY I)��Tip E�.-.�-�{ .i .-�.a CD R I V E �*x , l BAY,, r, 32,1n. 13 cz - H 21) 733-7092 Fax: (321) 733-._797 T STATE OF FLORIDA CERTIFIED BUILDING CONTRACTOR: DR HORTON HOMES 1430 CULVER DRIVE NE PALM BAY, FL 32907 7 . - TEL: (3 21) 1ry 3 3- 7 /� V 9 2 ' FAX: (321) 733`7972 STATE OF FLORIDA PROFESSIONAL ARCHITECT: ��( lV1ICHAEL. l�''I i. ANDERti7c 0N AR' N o . 17305 A.B. DESIGN GROUP, LLC 2194 HWY ALA, SUITE 301 INDIAN HARBOUR BEACH, FL 32937 q p q q _ Tel: (321) 802-3591 - DRAWING / CONTRACT DOCUMENT REVIEW BY BUILDER THE BUILDER ASSUMES ALL LIABILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS. r ,m` ANY ASPECT OF THE CONSTRUCTION (AS >)ESCRIBED IN THIS DRAWING SET) ARE UNCLEAR AND _N NEED OF FURTHER DETAILING OR EXPLANATION IN ORDER TO BUILD THIS PROJECT BASED ON THIS DRAWING SET, THE CORRECT PROCEDURE IS FOR THE BUILDER TO SUBMIT A WRITTEN R.F.I. (REQUEST FOR INFORMATION) TO THE ARCHITECT OR ENGINEER FOR <LARIFICATION. AB DESIGN GROUP WILL RESPOND TO ALL WRITTEN RFI's IN WRITTEN/DRAWN FORMS IN A TIMELY MANNER. AB DESIGN GROUP TAKES NO RESPONSIBILITY FOR INTERPRETATIONS OF CONSTRUCTION BY THE BUILDER WHEN NO RFI'II HAVE BEEN GENERATED FOR UNCLEAR ASPECTS OF THE CONSTRUCTION BASED'' ON THE DRAWING SET. DESIGN CRITERIA: ABBREVIATIONS REVISIONS -nDRIDA BuHDIING CODE, RE3IDENnAL, M1� e�A f iH EDMON (2020) -ALL LOCAL AND STATE CODES -OCCUPANCY —RESIDENTIAL, GROUP R3 - CONSTRUCTION TYPE — VB - MIN. INTERIOR FINISH — CLASS B -BASIC WIND SPEED — Vult=160 MPH Vasd=124 MPH - EXPOSURE - C -I—STORY RESIDENCE — -2—STORY RESIDENCE —MAX. HEIGHT AS PER LOCAL AND STATE CODES -...�.,,, -.. -ABV. ABOVE LAN. LAVATORY.. A/C AIR CONDITIONING LUM. LUMINOUS � ADJ.ADJUSTABLE M.C. MEDICINE CABINET ALT. ALTERNATE MFR. MANUFACTURER AMP AMPERAGE MIN. MINIMUM BD. BOARD M.T. METAL THRESHOLD CL CENTER LINE MTD. MOUNTED CAB. CABINET MTL. METAL CLG CEILING N.T.S. NOT TO SCALE CLR CLEAR O.C.ON CENTER CONC... CONCRETE PL PROPERTY LINE CPT CARPET P.B. PUSHBUTTON C T CERAMIC TILE PH. PHONE - D. DRYER PLY. 'LATE DBE. DOUBLE P D G.. DUAL GLAZED PR.R. PAIR DIA - DIAMETER P.T. PRESSURE TREATED DIM. DIMENSION R. RISER DISP DISPOSAL. RAD, RADIUS DDEEP R.A.G. RETURN AIR GRILL DRR. DOOR REF: REFRIGERATOR Ds. DOWNSPOUT RM. ROOM DTL. DETAIL R.O. ROUGH OPENING D.W.DISHWASHER S.C. SOLID CORE EXTDR EA EACH S.D. SMOKE DETECTOR ELEV. ELEVATION S.H. SINGLE HUNG EQ. EQUAL SHE SHEET EXH.- EXHAUST SHTHG. SHEATHING EXT. EXTERIOR SHWR. SHOWER F.G /P'X . FIXED GLASS Sim. SIMILAR F.G. FUEL GAS SL. SLIDING FIN. FINISH SL. GL. SLIDING GLASS FLR. FLOOR STD. STANDARD FLUOR FLUORESCENT SWs SHEAR WALL FR. DR. FRENCH DOOR SECTION FTG. FOOTING TEMP. TEiMPEREDGLASS GA. GAUGE THK. THICK GAR.: DISP: GARBAGE DISPOSAL T.O.C. TOP OF CURB G.F.I. GROUND -FAULT CIRCUIT T.O.P. TOP OF PLATE -INTERRUPTER T.O.S. TOP OF SLAB GL GLASS TYP. TYPICAL GYP. BD. GYPSUM BOARD U.N.O. UNLESS NOTED H.B. HOSE BIB. OTHERWISE H.C. HOLLOW CORE V.P. VAPOR PROOF MDR. HEADER W. WASHER HOT. OR HEIGHT WD. WITH INT. INTERIOR WDW. WINDOW W/H WATER HEATER W.E WROUGHT IRON DATE DESCRIPTION �n8�� 2-STORY CMu CONVERSION 1245/11 APf LIED COMMENTS FROM M. SEA'Y 01A5118 BID SET ISSUED 02/13/18 ADDED ELEV. 'X t 'K' WITH SIDINGS PER MARK BOWES 02/20/18 BID SET RE -ISSUED �AT/18 FOOTING REVISIONS PER M. BOUJES 0841110 ADDED VALLEY FRAMING DETAIL, UPDATED BOLLARD DETAIL oi/1hn9 DETAIL- 'ADDING BAR TO BOND i3EAM' ADDED TO 51.2A 02/16/19 PLAN MAINTENANCE 03/29/19 REVISED LINTEL SIZE AT FRONT ENTRY DOOR 04/25A9 ADDED ADDITIONAL RECEPTACLE IN GARAGE PER WILL BATSON _ __._ REVISED HVAC VOLUMES ON SQFT CALC SCHEDULE --- UPDATED LEDGER BOLT SIZE f SPACING S .§ ^ � � ki ,Z _'. S 04/25A9 IST FLR. LIVING 1104 SQ. FT. 2ND FLR Ga.LIVING 1501 Q. FT. TOTAL LIVING 2605 SQ. FT.. GARAGE 431 SQ. FT. LANAI 80 so. FT. FORC1i.. III SQ. FT. TOTAL 3095 SQ. FT. A/C VOLUME 22403.2 CU. FT. : '. '.. 04/26/19 06A9A9 -- REVISED I -JOIST LAYOUT 06/21/113 ADDED LED LIGHTS TO KITCHEN 4 BATHROOMS PER MARK 5CLES 09A3/19 LEDGER BOLT SPACINGS REVISED 11A5/19 ADDED COCOA PLUMBING RISER 01/01/20 REPLACE USP CONNECTORS WITH SIMPSON CONNECTORS 05A1/20 REVISED STAIRCASE AND STAIR SECTION DETAIL --- -- — INDEX OF DRAWINGS ARCHITECTURAL SHEET PG Cl—COVER SHEET PG GN— GENERAL NOTES PG Al —FIRST FLOOR PLAN PG AlA—FLOOR PLAN SECTIONS/DETAILS PG A2-SECOND FLOOR PLAN PG A3H-FRONT & REAR ELEVATIONS "H" PG A4H— LEFT & RIGHT ELEVATIONS "H" PG El —FIRST FLOOR ELECTRICAL PLAN PG E2—SECOND FLOOR ELECTRICAL PLAN PG Pl—FIRST FLOOR PLUMBING PLAN PG P2-SECOND FLOOR PLUMBING PLAN PG MI —FIRST FLOOR MECHANICAL PLAN PG M2-SECOND FLOOR MECHANICAL PLAN PG Dl —DETAILS PG D2 DETAILS PG D3—DETAILS PG WAl--WALL ASSEMBLY DETAILS PG WA2—WALL ASSEMBLY DETAILS PG WA3—WALL ASSEMBLY DETAILS PG WA4—NOT USED PG WA5 NOT USED PG WA6—WALL ASSEMBLY DETAILS STRUCTURAL SHEET PG S1-FOUNDATION PLAN PG S1.IA—DETAILS PG S1.2—FIRST FLOOR DOWEL, PLAN PG S1.2A—DETAILS PG S2—FIRST LIFT BEAM PLAN AND NOTES PG S2.IA—DETAILS PG S2.2A—SAFE LOAD TABLES PG S3-FIRST FLOOR FRAMING PLAN PG S3.1A-DETAIL8 PG S3.1B—DETAILS PG S3.1C—DETAILS PG S4--SECOND FLOOR DECK PLAN PG S4.2--SECOND FLOOR DOWEL PLAN PG S5—SECOND LIFT BEAM PLAN AND NOTES PG S5.IA—SAFE LOAD TABLES PG S6—ROOF FRAMING PLAN PG SN1 DETAILS DESCRIPTION Reviewed for Code Compliance universe{g DESCRIPTION 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 0 x S'U BIDI . & LOT: CREEKSIDE PHASE 2 LOT #83 MODEL: 41EHB "26059-HAYDEN" LEFT PAGE: COVER SHEET .60 MPH EXP. ( ARCHfTECT- STATE OF FLORIDA MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 DATE: /19/ 03 21 c SCALE:1/4"=1'-0" SHEET CI GENERAL NOTES SITE WORK TIMBER 1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL (FBCR) 1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT). 1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED 7th EDITION, (2020) . ALL REFERENCED CHAPTERS, CODE SECTIONS AND TABLES STATED IN THESEDOCUMENTS ARE UNDER HEREIN: FBCR 7TH EDITION (2020) UNO. 2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS; ROUGH GRADING, ON -SITE UTILITIES. A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL B. NATIONAI FOREST PRODUCTS ASSOCIATION: 2. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL I NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY FINISH GRADES, PLANTING AND IRRIGATION. C. SOUTHERN PINE INSPECTION BUREAU: THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE I STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER DESIGNED AND INSTALLED IN ACCORDANCE WITH FBCR 2020 CHAPTER 3, SECTION R301.2.1.2. 3. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE D. TRUSS PLATE INSTITUTE: ARCHITECT. I NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI 1-2014) ') 3. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TO WORK E. APA THE ENGINEERED WOOD ASSOCIATION PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND, 4. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN Yz THE HORIZONTAL I. ENGINEERED WOOD CONSTRUCTION GUIDE DISTANCE FROM THE NEAREST EDGE OF THE FOOTING. F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS 4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK 5 ALL BACKFILL AT STRUCTURES, SLABS, STEPS, AND PAVEMENTS SHALL BE CLEAN GRANULAR FILL. PLACE IN 8" LAYERS 2. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES OR OMISSIONS IN THE AND COMPACT TO 95% MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557-2012 E1 THE CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTION AND/ BUILDING SITE SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS, 3. MINIMUM NAILING PER CHAPTER 6- WALL CONSTRUCTION AND TYPICAL NAILING SCHEDULE ON PLANS. FABRICATION OF THE WORK. 4. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL COMPLY WITH CHAPTER 6- WALL CONSTRUCTION. 5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETYAND CONSTRUCTION PROCEDURES, TECHNIQUES, 6. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED, OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED CODES. 5. WALL SHEATHING SHALL BE PER STRUCTURAL, SEE ROOF/WALL/FLOOR SHEATHING FASTENER SCHEDULE ON SHEET SN1. 7 DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE) 6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACTOR 6. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24" AND THE MINIMUM AREA SHALL BE 8 FT . SQ. SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING 8 EXCAVATIONS TO BE A MINIMUM OF T- 0"BEYOND NEW FOOTING LINE, CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED. PLUMBING 9. THE GENERAL CONTRACTOR' MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE 1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL, 7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REQUIREMENTS, 2. WATER SUPPLY' LINES SHALL BE CPVC OR UPONOR PEX "A" (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS, 3. CONDENSATION LINES SHALL BE MINIMUM'%" PVC (SCHEDULE 40), INSULATED WITH'/i' AMAFLEX. 8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER. 10 -CONTRACTOR IS TO VERIFY THE ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY 4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH. WHICH COMPLIES WITH ALL LOCAL CODES HAVING JURISTICTION, INCLUDING ALL APPLICABLE STATE, CITY AND 5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE, 9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED, COUNTY BUILDING AND ZONING CODES. 6. N0 VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES. GARAGES AND CARPORTS 7. SIZE AND LOCATION OF CLFANOIJTS SHALL CONFORM TO FBCR SECTION P3005.2. 11, SWIMMING POOL, DECK, SPA, AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP 8. FIXTURE SUPPLY SIZES SHALL CONFORM TO FBCR SECTION P2903. 1. GARAGE DOOR A. ENGINEERED FOR MIN. WIND LOAD, LISTED ON COVER SHEET DRAWING. 9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER 10. DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF FBCR SECTION P2603.2. 12 TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, C. DETAIL TO BE ATTACHED TO PERMIT PACKAGE BY BUILDER BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION EXTERIOR WALL COVERINGS 2. I GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING AS PER SECTION R30T OPENINGS FROM A PRIVATE G GE C LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE 1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR PURPOSES SHALL NOT BE PERMITTED. OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH BE APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE THE WALLS FOR COMPONENTS AND C1 ADDING LOADS IN ACCORDANCE WITH FBCR TABLE R301.2 2 AS MODIFIED BY FBCR ( ) SOLID WOOD DOORS NOT LESS THAN 1 3/8 INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT LESS THAN BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT TABLE R301.2(3), MANUFACTURED SOFFITS SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE 1-3/8 INCHES THICK, OR 20-MINUTE FIRE -RATED DOORS. THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF EXTERIOR FINISHES 3. AS PER SECTION R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE AGRICULTURE AND CONSUMER SERVICES." 1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, %" THICK, OVER FRAMED WALLS DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO, 26 GAGE (0.48 MM) SHEET STEEL 1" MIN. RIGID APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS ON -METALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE THAN 2 COATS, 1/2" THICK, WHERE APPLIED OVER MASONRY OR CONCRETE. GARAGE. 2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE WITH ASTM-C926-18b, ASTM-C1063-19a & ASTM-C1787. 4. AS PER SECTION R302.6 & TABLE R302.6: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT 3. LATH & ACCESORIES PER ASTM-C-1063-19a & R703,7.1. ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT LIMITED TO: LESS THAN -INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE, GARAGES BENEATH HABITABLE ROOMS SHALL BE ALL STUCCO CONTROL JOINTS DETAILS SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR EQUIVALENT. "L" FLASHING HORIZONN TAL LATH AND PAPER DETAILS HORIZONTAL WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PIPE PENETRATION DETAILS VENT PENETRATION DETAILS PROTECTED BY NOT LESS,THAN'/-INCH GYPSUM BOARD OR EQUIVALENT. WEEP SCREED DETAILS CONDUIT PENETRATION DETAILS CASING BEAD DETAILS DRIP EDGE DETAILS CANTILEVER DRIP EDGE DETAILS CORNER BEAD DETAILS WINDOW CASING DETAILS STUCCO TO SIDING TRANSITION DETAILS WINDOW FLASHING DETAILS ' a 4. SHALL BE INSTALLED PER ASTM-C1063 -19a AND R703.7. FIRE RESISTANT CONSTRUCTION UNDER STAIR PROTECTION 1, ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 112" GYPSUM BOARD. R302.7, EXTERIOR CEILINGS 1. EXTERIOR CEILING TO BE 112" GOLD BOND BRAND EXTERIOR SOFFIT BOARD INSTALLED PERPENDICULAR TO THE FRAMING MEMBERS. THE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD IS TO BE SECURED TO THE FRAMING MEMBERS WITH 1 1/4" TYPE "W" DRYWALL SCREWS AT 12" O.C. (PER MANUFACTURER'S SPECIFICATIONS) . CONSTRUCTION OBSERVATION CONSTRUCTION OBSERVATION SERVICES 1 CONSTRUCTION ADMINISTRATION SERVICES ARE NOT A PART OF AS DESIGN GROUP'S SERVICES FOR THIS PROJECT. IT IS UNDERSTOOD AND AGREED THAT AB DESIGN GROUP'S SCOPE OF SERVICES DOES NOT INCLUDE PROJECT OBSERVATION OR REVIEW OF THE BUILDER'S/CONTRACTOR'S PERFORMANCE OR ANY OTHER CONSTRUCTION PHASE SERVICES, AND THAT SUCH SERVICES WILL BE PROVIDED BY THE BUILDER. THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS, AND FOR CONSTRUCTION OBSERVATION. Reviewea for Code Compliance Universal sciences CONTROL DATE: 12/10/20 (RM) 2194 HWY A1A, SUITE301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 IN w E U w Q F a E rCS1U1EB3DIV. 8e -REEKSIDE PHASE 2 LOT #83 PROJECT 04321.200 083R1 BdODEI.,: 4EHB "2605- HAYDEN" 0ARAG4E S VrM0: LEFT PAGE: GENERAL NOTES Y 160 MPH EXP. C ARCHFECT.n w_ STATE OF FLORIDA Y MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT 2119 DATE: 03 / / SCALE: 1/4"=1'-0" SHEET G _ -z-,> -as , .. apse aazrzaaaa��sww:tim's[a�,ebems�rov Ftt� vSu.4�H£S�FFkY ,yam �3.xs{k'n 23^�lfffi`ci:�1 n�. GROUND I WIND DESIGN SEISMIC 1 511.115,1 TO D.W IAC SOW 1 SPEED TOPOGRAPHIC DESIGN r WEATHERING' FROST LINE LOAD (MPH) EFFECTS' CATAGORY DEPTH NA I Ill G I NA INEGLIGAI I NA FLAME SPREAD AND SMOKE INDEX FOR WALL AND CEILING FINISHES SH, ACCORDANCE WITH SECTION F15C R302.31 THROUGH FBC R302.9.4 FLAME SPREAD AND SMOKE -DEVELOPED INDEX FOR INSULATION SHALL ACCORDANCE WITH SECTION MC R302JOJ THROUGH FHC R302.105 0 =_ FROM WINTER ICE BARRIER FLOOD AIR MEAN TERMITE DESIGN UNDERTLAYMENT HAZARDS a FREEZING ANUA i TEMP' REQUIRED1, INDEX TEMP. VERY HEAVY 42 NA SEE SURVEY NA NA LL 5E IN BE IN 2T-10' 2'-8" 15'-4" 10'_0 -10 -4" -1 4" 4 o 7 F-1 --- COVERED ANAI 1 sLsV C 11'-8" I 10'-011 7i(lH • S-Cs.D. 3❑ �:•:❖ :e•;��i.� Imo:•: BEDROOM #2 a'-e' cLG. c0 LIVING 9 I ROM ROOM a' -a' CII a, -a' CI-G. 9 _0 3 _g ,_loll 5'_8" 3I_8. _2 -- (2) 206s a 1 I I A I -- — I I I I 1R-iSH I = I B II POST I ° z 10 rU5/ BATH#2 .y�1°� VIc 1 I I ^ CIV . N s 010 a'-8' CLG. I- c i 1 11 K, KITCHEN e'-a' cLG. 1 e xib c0 3'-4 5'-4 3' 8 4' 0" 0' H B. W.H. 2868 SC 0 _ 20 MIN. STAIR DATA IOPf.= I `� I° 16 RISER 154' _ iREF `t 15 TREADS ° 10' ARCH i 3-SH BOLLARD C AS REG. — PER Ell B CODE IIF 5 _8 II 131_01, GARAGE III ro a' -a' cLG FOYER 0 Vlllc FLEX O 8'-8' CLG.m III a' 8' CLG. III W/12 3068 a III RANs III s I` r a r' ,.- • , r- r t� *.e�`'�.,,,L may,,,., .�"'"l � #? � ttl" �,.,�•�� GAI ROOFS < � I ���@ 4i Ki 454 tf s Z 3 i 1 4 GABLE ROOFS 10'ti0's4V HIP ROOFS IT<053W eF4I3?, « 4 ft= tt2 �ih FIGURE RM122(7) CC31#4;«TONENT AND CLADDING PRESSURE ZONES -10" 16'-0' X 1'-0' O.H. 20'-4" 21'-8 C7� 0 ❑s E CI O J U (2) 3052-5H 2'-10' 1'-0" I e @ PORCH 1 d 64, CLG. 4 10'-011 4 I'l4 - �9'-8° I D� SQUARE ZONE SO WH WM Mlt] W19 - MIN. WINDOW 10 5 3T/-50 CRITERIA EXTERIOR SWING 18 36/-41 DR. MIN. CRITERIA 5 34/-43- S.G.D. MIN. 41 CRITERIA -�- 16010 O.H.D. 112 5 31 1-34.6 12'xl2" SOFFIT 1 5 313/-49.9 BASIC WIND SPEED MPH = 160 (Vult) 11 INTERNAL PRESSURE COEFFICENT = f 0.18 BLDG. CAT.=II, EXP.=C, MEAN ROOF HT. 23'-0" PRESSURES HAVE BEEN MODIFIED PER FBCR 7TH ED. (2020) SECTION R301.2.1 TO MEET TESTED ALLOWABLE OR NOMINAL WIND LOAD VALUES FROM THE PRODUCT MANUFACTURER. CONTROL DATE OU01121 NOTE: SOFFIT INSTALLATION IS TO BE PER MANUFACTURER'S SPECIFICATIONS THAT ARE TO BE PROVIDED BY THE BUILDER WITH PRODUCT APPROVAL AND NOA SUBMITTALS. FT. FT. FT. FT. FT. FT. FT. Ft. MASONRY / FRAME .,.t. WALL LEGEND 8'-8' BLOCK WALL UN.O ON PLANS I€ BRCa. HGT. VARIES c 8' BLOCK WALL } UN-0 ON PLANS INTERIOR O "j BRG. WALL UN.O. ON PLANS 4' INTERIOR NON LOAD BRG. WALL U.N.O. ON PLANS -ALL INTERIOR DOORS TO BE 6'-8' -ALL EXTERIOR DOORS TO BE 6'-8' UNLESS NOTED OTHERWISE FIRST FLOOR PLAN SCALE: 1/4' = 1'-0' NOTE: -2-8 LOUV. DOOR W/ AIR HANDLER ON METAL STAND OR 2-8 SOLID DOOR W/ RETURN PLENUM AND RETURN AIR GRILLE. -VERIFY CONDENSER PAD LOCATION WITH SITE PLAN -OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LE55 THAN 1 3/8' (35 MM) IN THICKNESS, SOLID OR HONEYCOMB -CORE STEEL DOORS NOT LESS THAN 1 3/8' (35 MM) THICK, OR 20-MINUTE FIRE -RATED DOORS. -THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE < ITS ATTIC AREA BY NOT LESS THAN 11/s"(12.1mm) GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED FROM ALL HABITABLE ROOMS BY NOT LESS THAN TYPE X GYPSUM BOARD OR EQUIVALENT. -UNDER STAIR PROTECTION: ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2 INCH GYPSUM BOARDS. FBCR 2020 CTTH ED.) 302.1 - EGRESS NOTE: DO NOT SHUTTER FRONT DOOR. FRONT ENTRY DOOR TO HE EGRESS POINT WHEN THE HOME IS SHUTTERED. - REFER TO BUCKING DETAILS FOR BUCKING AND RO NOTES. -FRAMED WALL SEPARATION BETWEEN THE UNCONDITIONED GARAGE AND CONDITIONED SPACED SHALL HAVE AN INSULATION R VALUE OF R-13. -CEILING R VALUE TO BE R-30 INSULATIONABOVE CONDITIONED SPACE. -FOR CONSISTENCY, THE VOLUME CALCULATIONS ON PLANS Al PROVIDED BY THE HVAC CONTRACTOR AND ARE OF THEIR CLOSEST ALLOWABLE SOFTWARE TOLERANCES. -OPENING INFORMATION BELOW IS DIRECTLY FROM THE PLAN SET. U-VALUE AND SHCG ARE INFORMATION PROVIDED BY THE MANUFACTURER AS LISTED IN THE RESPECTIVE PRODUCT SPECIFICATIONS Now Reviewed for Code Compliance Universal Engineering 1B Sciences 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 tho \\ T z• ARCHffECT- TE 7-O- MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT DATE: 03/19/21 SCALE: 1/4"=1' — O„ SHEET 1_ "J I, Q 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www. a bd esigngrou p. com AA #: 0003325 0011 F tzi U I O E U h 4 F A FF 128,2605- UBDIV. Be LOT: CREEKSIDE PHASE 2 LOT #83 ROJECT: 4321.200 083Rl ODEL: 4EHB HAYDEN" GARAGE SWING: LEFT PAGE: FLOOR PLAN SECTIONS / DETAILS 60 MPH EXP. J ARCHrrECT= STATE OF FLORIDA - MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 D TE 03/19/21 SCALE: 1/4"=1'-0" SHEET AI A i d ,i A I I' -S" 2' -4" 3052-SH EGRESS o 12 I �J° C7 I I BEDROOM #5 N 8'-8' CLG. �I � 7 777, (2) 3052-8H UPSTAIRS LIVING 8'-8' CLa �r I 12' - 01' 3052 -SH Cr 12KRF, ►.� ,� ' , 'i„ ♦� ►ei I r I ❑ a I c ) 3052 - H EGRESS It— I 8' a ICLG. I QC I. EIJI xU L] 3052-SH 3052-5 2040-SW I LINE OF IST EGRESS EGFRESS TEMP FLOOR FLOOR SELOLU -0 �' 0 �'_4" 5' 4 g'-m" 2'-4" 2'-4" 39' SECOND FLOOR PLAN SCALE: 1/4 = 1'-0' v N -- I m .o I 2194 H WY A1ASUITE 301 +I INDIAN HARB06R BEACH, FLORIDA 32937 PH: 321-802-3591 4 www. abdesigngroup.com �Y. AA #: 0003325 W y U W O F 24 C w 0 F y r A I r� A a Ih � a� irk SUBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #83 'ROJECT# 04321.200/083R1 Reviewed for Cc& MODEIz Compliance 4 E HB Universal Engineering sciences "2605— HAYDEN" � GARAGE SWING: la LEFT SECOND FLOOR PLAN 'SAGE: SCALE. 1/4 = F-0' -FRAMED WALL SEPARATION, BETWEEN THE UNCONDITIONED SECOND GARAGE AND CONDITIONED SPACED SHALL HAVE AN INSULATION R VALUE OF R-13. FLOOR PLAN -CEILING R VALUE TO BE R-30 INSULATION ABOVE CONDITIONED SPACE. -FOR CONSISTENCY, THE VOLUME CALCULATIONS ON PLANS ARE PROVIDED BY THE HVAC CONTRACTOR AND ARE OF THEIR 00 MPH EXP. C CLOSEST ALLOWABLE SOFTWARE TOLERANCES. -OPENING INFORMATION BELOW IS DIRECTLY FROM THE PLAN SET. U-VALUE AND SHCG ARE INFORMATION PROVIDED BY THE MANUFACTURER AS LISTED IN THE RESPECTIVE PRODUCT SPECIFICATIONS m■���EL1 MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 n` 5 mi PEPS' : 03 19 21 DATE: SCALE: 1/4" 1 ' n SHEET/ 2 -i 26'-8" BLDG. PGT.� _ _ SHINGLE ----- - ROOF - - -�T FYPON I6'X48' 12 - - DECORATIVE L I I SHUTTER OR -r _ EQUIVALENT IS'-S" 2ND FLR.h - - - - $18' S" 2ND FLR. SRCs, HGT. r SRC;. HCsT. I' -ro' FYPON I EQUIVALENT X17 OR EQUIVALENT I'I 4' RAISED BAND BE - ) 6' RAISED 6' RAISED 12 I I BAND (TYP.) BAND _ -- N --_� - T-- -� 8 IN. F 10 -0 3/4 —$ 3/4' 2ND FIN. FLR. 2ND LR. _ _ SRCz. HCaT. - ® ENTRY OPT. COACH LIGHT I dl ❑ I I ® A ® I A TYP. 4" RAISED ® r I I BAND 7TY10J 8" RAISED BAND (TYP.) 0 _0 FIN. FLR.o `' $0'-0" FIN. FLR. 2ND FLR. _ SRC. HCsT.'� I' 10'-0 3/4" 2ND FLR� ___ FIN. FLh2/5R3. HeT. 8'-8' CLG. HGT.h 0'-0" FIN. FLR.$ FRONT ELEVATION SCALE: 1/4 = P-0' TEXTURED FINISH NOTE: WALL FENESTRATION FLASHING AS PER F5CR R103.4 I� REAR ]ELEVATION SCALE: 1/4 = 1'-0' TEXTURED FINISH 18'-8" 2ND FLR. BRCS_ "GT. I I 10'-0 3/4' 2ND FLR. r-- FIN- F-LRJER _ ACT. CLG_ HGT. r-- 4B I A' i TYP. —_--i�0'-0" FIN. FLR MODEL 2605-HAYDEN-4EH8 (2-Story) AREA OF ATTIC = 1541 SQ. FT. NET FREE VENTILATION AREA REQUIRED 1/ 300 REQUIRED VENTILATION AREA = 1541/300 5.14 SQ. FT. 5.14 = 739.68 5Q. IN. MIN. REQUIRFDVENTILATION = .4X 739.68 IN UPPER PORTION OF ATTIC = 295.872 SQ. IN. (BALANCE TO BE PROVIDED IN SOFFITVENTS) OFF RIDGE VENTILATION AREA = 138 SQ. IN. PER VENT(netfree area) TOTAL ftOFVENTS REQUIRED = 2.14 TOTAL it'OF VENTS PROVIDED = 3 SOFFIT VENTILATION AREA LINEAR FEET OF SOFFIT REQUI RI 7 SQ. IN. PER LIN EAR FT (net free area) 42.27 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 I PH: 321-802-3591 www.abdesigngroup.com F W U W 0 F 0. U3 w -x 0 W SiJBI7iv. 8C LC7111 CREEKSIDE PHASE 2 LOT #83 PROJECT* 04321.200/'083R1 DdODET • 4EHB "2605-HAYDEN GARAGE SWING: LEFT PAGE: w . FRONT& REAR Reviewed for Coda ComELEVATION "H" plianne Universal Engineering Sciences L60 MPH EXP. C ARCHrrECT: STATE OF FLORIDA MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 1735 PRINT DATE: 03/1921 N.... SHEET A3H M.: 10'-0 3/, a' -a FRAME DOWN FOR FYFON SKTllXl-1 OR EQUIVALENT 18'-8' 2ND FLR. BRCS. HGT 10'-0 3/4" 2ND FLR. F'N. FLR./PR s. HGT a' -a' BRCz. HGT a ENTRY LEFT ELEVATION SCALE: 1/4 = 1'-0' TEXTURED FINISH ]RIGHT ELEVATION SCALE: 1/4 = I'-0' TEXTURED FIN15H la'-8" 2ND FLR. --�BRCz. — 10 -0 3/4' 2ND FLR. FIN. FLR. 8'-g" BRCS. NCxT. --GDel rMiRY - — 0 -0" FIN. FLR. Ia'-V 2ND FL 5RCz. HGT. 0'-0 3/4" 2ND FLR. —$FIN. FLR./5RCz. HC,T. CLa HeT. 0'-0" FIN. FLR. Reviewed for Code Compliance 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 W td W �o F 0. U h W 4 F A C: 9UBDIV. & LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT# 04321.200 083R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: RIGHJEXP. LEF ELEVATI 60 MPH ELECTRICAL FLEGEND T ' SYMBOL DEFINITION Ni wF 1211 OUTLET 20 AMP SINGLE F 110V OUTLET 110V OUTLET 0 OF OUTLET WIRED _ TO SWITCH H 110V OUTLET EQUIPED WVGRND FAULT GIN INTERUPTER (TAMPER RESISTANT TYPE) _-.• 220V OUTLET (4) WIRE CONNECTION FAULT GFI OUTLET INTERRUPTER I SWITCH " SWITCH 3-WAY OPER �4 SWITCH 4-WAY OPER �I I� WALL MOUNTED I LIGHT Cli LIGHT �. O LED CLG LIGHT OL LED VAPOR PROOF LIGHT O Vill VAPOR PROOF LIC714T RECESSED CAN I CFM PER 86i FT s i . eVENT. FAN VENT. FAN W/LIGHT 1 CFM PER SQ. Fr. V.AIXT LIGHT FIXTURE (SF"EC'S TBD BY BUILDER) FLUORESCENT 2-BULB WRAP Ir' ® AROUND 4 (RECESSED) WI FLUORESCENT 2-151,11-15 WRAP I LIGHT AROUND (SURFACE MST.) M� 2' FLUORESCENT I I, li 4 4- FLUORESCENT I!I ; p t 4' TRACK LIGHT PANEL METER R BACK-& h SMOKE DETECTOR W/ HARDWIRE WALL MOUNTED BATT, BACIK-UP SD. SMOKE DETECTOR W/ HARDWIRE S/�%O GARBCN MONOXIi 9MOKE DETf=GTOR BATT. BACK-UP W/ HARDWIRE INTER -CONNECTED SHALL BE A DISTANCE COMA OF NOT LESS THEN 4' FROM WALL PENDANT LIGHT - NATURAL GAS OUTLET IT_ . TELEPHONE JACK WATER FEATER IGNITION SOURCE y DISCONNECT TO B ELEVATED x AIR CONDITIONING TO BE 210V UNO DISCONNECT SEE A14U ON THIS SHEET TV TELEVISION JACK CEILING BOX REQUIRE TO BE SUPPORTED N O J-BOX ACCORDANCE W/ BOX MARKED AS SUCH FOR INSPIECTION i CEILING BOX REQUIRED SUPPORTED I GEICEILING FAN/LIGHT ACCORiIN A 1 DANCE UI/ BOX MARKED AS SUCH FOR . , INSPECTION 24' INCANDESCENT „ LIGHT STRIP 36, INCANDESCENT n n n n n n { o LIGHT STRIP nnn® 48' INCANDESCENT LIGHT STRIP FLOOD LIGHT k v. OPT. SECURITY a KEYPAD .FOR s. FUSH-BUTTON CHIMES F HTHE If `a USES PORT € G • LOCATION OF TV JACKS a PHONE OUTLETS 4 FANS TO BE VERIFIED • HOMEOWNER PRE -CONSTRUCTION MEETING. • ALL B 4 20 AMP BRANCH CIRCUITS TO BE ARC FAULT PROTECTED PER ELECTRICAL PROVISIONS OF POOR -ITH EDITION (2020) a NEC 210.12 201-1 EDITION. + 20 AMP DEDICATED LAUNDRY CIRCUIT. • GFI is ISLAND (NOT ON KITCHEN CIRCUIT) • DISHWASHER DISCONNECT TO BE LOCKOUT IN PANEL • BATHROOM EXHAUST FAN TO HAVE MIN. CAPACITY OF 50 CFM INTERMITTENT PER ELECTRICAL PROVISIONS Or SECTION MI50"13 FBCIIIii EDITION (2020). • LAUNDRY ROOM RECEPTACLE SHALL BE GROUND FAULT CIRCUIT-NTERRUPTER PROTECTION FOR • WIRRZ THIOD SHALL BE NON METALLIC CABLE DER ELECTRICAL PROVISIONS Or FBCR TTH ED (2020). • ALL WORK TO COMPLY WITH ELECTRICAL P1lilOVISIONS OF THE FBI 7TH ED (2020). • ALL LAMPS SHALL BE SELECTED BY BUILDER Ab 15% OF LIGHTING MUST BE ENERGY EFFICIENT TYPE PER P-- ENERGY CONSERVATION (RESIDENTIAL EMERY IE EFFICNCY) 202ID 1tH EDITION R49W METER FIELD VERIFY LOC. GFI' IRRIGATION OUTLET 40' AF.F. COVERED CEILING MTR LIGHT TO BE INSTALLED, I GF1 PROVIDE OPT. F FOR U ❑ J J ❑ J J C J LAN J PRE -WIRED DINING CLG FAN LIVING ROOM Ali PRE -WIRED I, � -- 7 CLG FAN ` BDRM. #2 GFI Y II I I 1 I TO 2ND FL\ SWITCH iN I I— 1 I I S O SWITCH �` CABINET I �. KITCHEN z� BATH #2 ' OUTLETi�--- r -r FOR DWI I*„r GFI s — — PAN. J PB. FO GFI a 44" GFI • 448 DOOR GARAGE t A.F.F. APR SIC GFI IL O-- �! -- F'T. BOLLARDAS REQ. - 1 PER BLDG. CODE / FLEX , � KEYLESS 4II FIXTURE z GFI FOYER III PR£ WCLGIRED AN GARAGE t III DOOR PREWIRE ' GARAGE C C".-- o - E ----__--- -------- COACH LIGHT owl P.B. F CHIMES '� II PORCH one -- — FIRST FLOOR ELECTRICAL PLAN SCALE: 1/4' 11-V 11 nil it no 1 �I I - — _ _ — _ - LED LIGHTING I SINGLE LAV. BATH 02 OUTLET FOR VENT OR MICRO WP Panel MAIN -A PANEL: VOLTAGE: 120 0 240 V -1 Ph MAIN: 150 Amp I FEEDER #1C.nIIlv'Jh1° 1 r:u(f jnrl 1(2"C: OR 3-#210ALTHWN&1-#6Cu(G)in1IQ" G. Wire Pole Bkr Desctiption, Watts Circuit Circuit Watts Description #12 1 20 Exterior Receptacle 3FI fa II ll: 1 00 1 2 Space 912 2 20 Irrigation Pump — uOCR--t — -- -- 4_ Space 5 6 6240 A/C C.U. PANEL - A PANEL: 42.crt. bfeakei VOLTAGE: 120; 240 V -1 Ph MAIN: 150 Amp M.L.O. FEEDER -�-#1.1:1111IVJh1R1 WI 11(,)In1112"C OR 3-#210ALTHWN&1-#6Cu(G)in11f2"G. Wire. Pole Bkr Description _Watts 1500 -_ 1100 14r10 1�00 Circuit_ Circuit Watts Description #.12 1 20 _ Small Appliance _ 11 Hood GFI -- - - Small Appliance Refngerator Dining Receptacles AFC'1 - — Bath GFI Receptacles Foyer I Hall AFCI _ _ 11 Rm. Lanai. Ketch=n, Din I t . AFL Space _ _ SD&GO AFCI Space _ Bedroom #2! Bathmon # 4Fl,l Bedroom 93 AFCI Bedroom #4/Opt . Bed# F,#61 ,I,1 [OR PTI1 Opt. 3-Car Garage Dc-n Opcli?l t;FI Space Space -_ - - Space Space A/C A.H.U. (Heater 5 KVA ate 'J 1 F 9 11 1 x 2 8000. Range # 12 1 20 #12 # 12 1 1 20 6 ° 4500 WaterHeater 20 # 12 #12 1 1 20 20 — iv.10 1200 900 1D! 12 1200 15DO Disposal GFI Dishwasher GFI #14 1 15 14 _ 5000 Dryer GFI #14 1 15 900 �Iri 15 11._ 19 16 18 1500 Washer GFI 914 1 15 20 1000 Garage Door Opener GFI 21 _ 22 1200 Garage I Exterior Us & Receptacles AFCI #14 1 15 rlC 24 900 Bedrocrn #1 AFCI #14 1 15 1r 900 X00 -_ � 1525 27 _ 29 31 _ 31 26 900 Bath #1 AFCI #14 #12 1 1 15 20 29 30 _1200 1000 2nd Roar HallfSM2nd FLLIv/Laun.AFCI Irrigation controls mly 32 Space _ _ 34 Space 3� 7 39 41 36 Space _ 38 Space 48 . 2 35 40 42 Space _ _ Space Load subject to demand factor cal•.,ulatiolls ± Ilne 17(1 27900 Load subject to demand facto Demand Factor Calculations. ABBREVIATIONS: AFCI: ARC FAULT CIRCUIT INTERRUPTER NC: NON -COINCIDENT LOAD GFI: GROUND FAULT INTERRUPTER fatal load subject to demand factor 45500 First 10000 watts at 100% _ _ _ Remaining watts a1 40% 10000 142C0 Total A/C load — - _ li165 Total Cmnecled Lcad Watts Total Amosi�n2tl<,' 24 )wIts) '1r4l 65 49.9 150 AMP ELEC: RIi RISER NOT TO SCALE. GENERAL NOTES - A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR ITH EDITION (2020). LOCAL CODES, AND ALL LOCAL POWER COMPANY REQUIREMENTS. B. ALL CONDUCTORS SHALL BE TYPE THHN/THWN UNLESS NOTED OTHERWISE. POWER GRADE PROVIDE ISO AMP, 120/240 VOLT, I PHASE SECONDARY - ELECTRICAL SERVICE. PROVIDE 3 01 COPPER (CU) IN 1-Irz" DIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3 02/0 ALUMINUM (AL) IN 2" DIA SCHEDULE SO PVC CONDUIT UNLESS SERVICE IS PROVIDED BY THE ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC COMPANY PRIOR TO BID. Qr'® 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH:321-802-3591 www.abdesigngroup.com AA #: 0003325 Tfl 50 2 #6 25 2 #10 20 20 1 1 #12 #12 30 2 #10 20 1 #12 20 1 #12 1 I #12 1 #12#12 l line LOAD CALCULATION IS BASED ON A/C NON -COINCIDENT LOAD I Q General Lighting & Receptacle Load Total AX Square Feet 2605 General I &Rec 3 W l5q. FL 7815 H141ats 3.at65W/Li htat100% 195 General 8010 —. Clots# vattslc Total watts General Us & Rec Panel A 111 7281 8010 Fit s � ` it PROVIDE 302/0 CU, THWN + 1% CU IN 2' CONDUIT OR 3 04/0 AL, THWN + 1% CU IN 2' CONDUIT OR 2/0 AL. S.ER (CONDUIT TO TERMINATE ABOVE SOFFIT • OVERHANG.) UEI;3l r& LOT: COMBINATION SERVICE 15ID AMP CREEKSIDE DISCONNECT SWITCH AND 120/240 VOLT M ELECTRIC METER IN I HA E PHASE 2 NEMA 3R ENCLOSURE MILO PANEL LOT # 8 3 moArzP aROJECT* MGB 1 `191 9nn /nA3R1 CABLE TELEVISION lii031 SERVICE ENTRANCE 4EHB EQUIPMENT "2605—HAYDEN" 1,7�ARAGE SWING: LEFT AGE: 1 e4 CU SERVICE GROUND CONNECTED TO FIRST CONCRETE ENCASED FOOTER STEEL PER FLOOR ELECTRICAL PROVISIONS OF THE FBCR TTH EDITION (2020'. ELECTRICAL 5/8" DIA X 8 FT LONG COPPER CLAD GROUND ROD FLAN u= �_60 M1'H EXPO C Reviewed for Code ARCHrTECT' cornpbance STATE OF FLORIDA Uni4ela. ,;'J'neering� Sclr;nces 1 MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 fSD TE: 03/19/21 EET 1 , E I TELEPHONE SERVICE ENTRANCE EQUIPMENT INTERSYSTEM BONDING TERMINAL AT LOW VOLTAGE CONNECTIONS ELECTRICAL LEGEND SYMBOL DEFINITION NOTES _e 125V OUTLET 20 AMP SINGLE POLE 3/ 110V OUTLET 110V OUTLET In OF OUTLET WIRED TO SWITCH 110V OUTLET EOUIPED WiYaRJD FAUL INTERUPTER (TAMPER RESISTANT I T'PE) 220V OUTLET (4) WIRE CONNECTION WP EXT. WATERPROOF GROUND FAULT GFI OUTLET INTERRUPTER SWITCH SWITCH 3-WAY OPER �74 SWITCH 4-WAY OPER 1� WALL MOUNTED 1 LIGHT CEILING LIGHT O LED CLG LIGHT O VP LED VAPOR PROOF LIGHT O VP VAPOR PROOF LIGHT ORECESSED CAN eVENT. PAN I CFM PER SO. FT. VENT. FAN W/LIGHT I CFM PER SO. FT. VANITY LIGHT FIXTURE (SPEC'S TBD BY BUILDER) ® FLUORESCENT LIGHT 2-BULB WRAP AROUND (RECESSED) 4'X2' FLUORESCENTLIGHT WRAP AROUND (SURFACE MT.) 2' FLUORESCENT *FLUORESCENT p p/� 4' TRACK LIGHT 0 PANEL own METER O SD. TT. SACK -UP W1 HARDWIRE SMOKE DETECTOR WALL MOUNTED MATT, BACK-UP SA SMOKE DETECTOR W/ HARDWIRE S/GO CARBON MMMIM SMOKE DETECTOR BATT. BACK-UP W/ HARDWIRE INTER -CONNECTED SHALL BE A DISTANCE COMBO OF NOT LESS THEN 4' FROM WALL PENDANT LIGHT NATURAL GAS OUTLET ► TELEPHONE JACK WATER HEATER IGNITION SOURCE WH F DISCONNECT TO BE £L£VATED a �/ AIR CONDITIONING TO BE UNO_ SEE AHU N DISCONNECT T44814EO TY TELEVISION JACK CEILING BOX REQUIRED O TO BE SUPPORTED IN ACCORDANCE W/ BOX J-BOX MARKED AS SUCH FOR INSPECTION S RECURR ED TO TO ME SUPPORTED N ME CEILING PAN/LIGHT ACCORDANCE W/ BOX MARKED AS SUCH FOR INSPECTION 24' INCANDESCENT LIGHT STRIP nnnnnn 36' INCANDESCENT LIGHT STRIP nnnnnnnn 48' NC.ANDESCENT LIGHT STRIP FLOOD LIGHT OPT. SECURITY KP KEYPAD G P.B. PUSH-BUTTON FOR C4IMES --4-� USB PORT • LOCATION OF TV JACKS < PHONE OUTLETS < PANS TO BE VERIFIED • HOMEOWNER PRE -CONSTRUCTION MEETING. • ALL 15 t 20 AMP BRANCH CIRCUITS TO BE ARC FAULT PROTECTED PER ELECTRICAL PROVISIONS OF FBGR TTH EDITION (2020) t NEC 210.12 2011 EDITION. • 20 AMP DEDICATED LAUNDRY CIRCUIT. • GFI s ISLAND (NOT ON KITCHEN CIRCUIT) • DISHWASHER DISCONNECT TO BE LOCKOUT IN PANEL • BATHROOM EXHAUST FAN TO HAVE MIN. CAPACITY OF 5O CFM INTERMITTENT PER ELECTRICAL PROVISIONS OF SECTION MI50-13 FBCR ITH EDITION (2020). • LAUNDRY ROOM RECEPTACLE SHALL BE GROUND FAULT CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL ON FEEDERS • WIRING METHOD SHALL BE NON METALLIC CABLE PER ELECTRICAL PROVISIONS OF FBCR 7TH ED (2020). • ALL WORK TO COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR TTH ED (2020). • AI I I AMPS SHALL BE SELECTED BY BUILDER AND IS% OF LIGHTING MUST BE ENERGY EFFICIENT TYPE PER F.B.C. ENERGY CONSERVATION (RESIDENTIAL ENERGY EFFICIENCY) 2020. Tth EDITION R404.1 � lu I� I I I BEDROOM #S BEDROOM #4 UPSTAI LIVING PRE -WIRED \ , PRE -WIRED GLG FAN I' ) GLG FAN qP L I LAUN. BATH #3 OFT. OW _ A/C ` l y R/p VP S/GO l S.D. - r ' WALL MOUNTED - =- - ' LLIGHT W/SWITCH INi �O) (� \ ATTIC f r \' , ♦ BATH #1 BEDRUUM #3 L_ ' GF1 QQ- PRE-WIRED GLG FAN IL I PRE -WIRED GLG FAN BEDROOM #1 I CaF11l � II 1•I I•li II I it I SECOND FLOOR ELECTRICAL PLAN SCALE: 1/4' = 1'-0' N o 0 L 0 0 L I 1 1'-4' I LED LIGHTING DOUBLE LAV. BATH 03 Reviewed for Code a] Compliance Universal Engineering Sciences LED LIGHTING @ DOUBLE LAV. BATH el 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 J F U W 0 E U W O F A sVBDIV. & LOT: CREEKSIDE PHASE 2 LOT #83 PROJE4 'T* 04321. a0 083 R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: SECOND FLOOR ELECTRICAL PLAN 160 MPH EXP. ARCHfTECT- STATE OF FLORIDA MAR 2 2 2021 MICHAEL C. ANDEF AR NO 17305 Jr' A DATE: 03 19 21 I SCAT E:1/4"=V-0" SHEET E2 IN s TUB/ _ —J S14lllR r i — ----- f 7 FIRST FLOOR PLUMBING PLAN SCALE: 1/4 = I'-®' Ia A -A. LA v 3' , WC (ALTERNATE LEFT) PLUMBING RISER DIAGRAM R 7Reviewed for Code lnOiance „ , P _ngineering ;IEnces 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W y U WW O F E4 cNa h W O h A SVBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT* 04321.200 083R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWINGE: LEFT PAGE: FIRST FLOOR PLUMBING PLAN 60 MPH EXP. C ARCHrrECT: STATE OF FLORIDA MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT DATE- 03 19 21 SCALE: 1/4"=1'-0" SHEET T-)I tT+ r— L V_ L V. 2:-8' 2'-0" ----- r-----� US/ Cf T. � : S - i �F- 131-10" IL — IL I I I fi — 13' - 3' W.G � Lij 36'X60' SHWR W/ENCL p .2 I I I SECOND FLOOR PLUMBING PLAN SCALE: 1/4 = I'-0' 91 Reviewed for Codo Comppliance Universal Engineeeinp Sciences 2194 HWY AIA, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W y U W O F 0. U w 4 F A F� c � S svBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT# 04321.200 083R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: SECOND FLOOR PLUMBING PLAN 60 MPH EXP. C ARCHrrECT. STATE OF FLORIDA MICHA& 2ANDOEI.SON 11 AR NO 17305 PRINT DATE- 03 19 21 SCALE: 1/4"=1'-0" SHEET P2 LLcJ �L n - - - - - .ANAI UI ---- L F W L. w� U W O F 0. v h A F A F� ti sUBDIV. & LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT* 04321.200 083R1 MODEL: 4EHB "2605-HAYDEN" ,rARAGE SWING: LEFT PAGE: FIRST FLOOR MECHANICAL PLAN 60 MPH EXP. i DATE: 03 19 21 SCALE: 1/4"=1'-0" SHEET mI 12X& PASS THRU 1. JI .15 cr-m 50 GFM 81X4 45 CFM 5. f8X4 11 E50 45 CFM, cl=m C 4- IOX6 15 GFM 1111MOMM Reviewed for Code Compliance Universal Engineering Sciences SECOND FLOOR MECHANICAL PLAN SCALE: 1/4 a 1'-0' N4 PA tz� U3 94 14 t. 6 O 0. rA E4 Ny { i LU t. H, SUBDIV. & LOT: CREEKSIDE PHASE 2 LOT#83 PROJECT# -�d 04321.200/083R1 A MODEL: 4EHB 2 6 0 5 — HAYDEN" GARAGE SWING: LEFT PAGE: SECOND FLOOR MECHANICAL PLAN 60 MPH EXP. G' W� PRINT DATE: 03/19/21 SCALE: 1/4"=1'-( SHEET PER FLR. PLAN 1/2' CLG. I 1/2' DRYWALL SECURE BT. — PLATE TO SLAB W/ 10d MASONRY NAIL e 32' O.C. MAX FIN. FLR 2X4 TOP PLATE PRE-FAB TRUSS 2X4 WOOD STUDS ®24' O.G. SLAB NOTE: STUDS IN PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURES AND WALL CABINETS SHALL BE NOT LESS THAN 2x4, WHERE SPACED NOT MORE THAN 16" O.G. OR, NOT LESS THAN 2x6, WHERE SPACED NOT MORE THAN 24" O.G. TYP. INT. WALL (NON-BRG. ;ALE: 3/4' = I'-0' FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR 905.1.1. ROOF SHEATHING THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE PRE-ENG TRUSS MTL. DRIP EDGE 2x FASCIA PER I,-0, TYP. ELEVATIONS VENTED SOFFIT 5/8' GYPSUM 5 OR 1/2' HIGH STRENGTH CLG. BOARD 1/2" DRYWALLS 3 5/8' OR 5 3/8' — METAL STUDS 24' O.G. 20 GA METAL TO BE INSTALLED IN WALLS RECEIVING UPPER/ LOWER CABINETS AND TUB/SHOWER 25 GA. METAL TO BE INSTALLED IN ALL OTHER WALLS. STUDS TO BE SPACED 16' O.C. AT 2ND FLOOR WALLS ADJACENT TO STAIR WELLS AND BATHROOM WALLS W/ TILE FINISH WOOD BASE5OAR0- 3 5/8" OR 5 3/8, TOP CHANNEL (25 GA.) 1/2' DRYWALL 3 5/8, OR 5 3/8, BOTTOM CHANNEL (25 GA.) SECURED TO CONIC FLOOR W/ 3/4' PAP t TO WOOD FLOOR W/ 1/4' WOOD SCREW 1-STORY FINISH FLOOR TYP. INT. WALL METAL STUDS /1_A1 (NON -BRIG.) D� SCALE: 1/2'=1'-0' SEE ENERGY CODE FORMS INSULATION R-VALUES REFERENCE STRUCTURAL PER ELEVATION R-4.1 INSULATION WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS REFERENCE STRUCTURAL Ix2 P.T. FURRING — STRIPS + 24' O.G. 1/2' THICK, 2 COAT PORTLANDt 8' GMU CEMENT PLASTER APPLIEDI/2' GYP. WL. BD.- DIRECTLY TO MASONRY WOOD BASE — 0'-0" FIN. FLR --- - n W/ WINDOW OPENING SCALE: 3/4' =1' -0' FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR S05.1-1. ROOF SHEATHING THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE STRUCTURAL PRE-ENG TRUSS MTL. DRIP EDGE 2x FASCIA PER ELEVATIONS In VENTED SOFFIT BOND BEAM SOLID GROU1 W/ (I)- "5 (2) COURSE 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 5" DIA. SLEEVE, DO NOT GUT 2A­)PIPE THROUGH BOND BEAM D1 SCALE: 3/4"=1'-0" 0'-0' FIN. FLR ROOF 5HEATHING THICKNESS IS ENGINEERED PER ASGE 1-16 IN ACCORDANCE WITH FBCR 2020 ITH EDITION, SECTION R301.13 AND 1609.5.1. B TYP. WALL SECTION NO OPENING NOTE: METHOD TO BE USED FOR THE ul Y4./✓-I\L!-I I ij..l�l I� I-'Ivvvl�r �.wi� WITH FBCR 905.1.1.1 OF THE FBCR 2020 -1TH EDITION IS 1*4 WHICH USES (2) TWO LAYERS OF ASTM D226 TYPE II OR ASTM D4869 TYPE III OR TYPE IV UNDERLAYMENT. FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR 905.1.1. ROOF SHEATHING THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE MTL. DRIP EDGE 2x FASCIA PER ELEVATIONS VENTED SOFFIT WALL SHEATHING 44ICKNES8 AS PER SHEET SNI. SECURE PER FASTENER SCHEDULE ON SHEET SNI PRE-ENG. GABLE TRUSS WEEP SCREED 2x P.T. SECURED PER STRUCTURAL DETAILS 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0'-0" FIN. FLR,L 8' GMU C4LILK AND SEAL LINE O NOT CUT _�-I;' P/C SLEEVE FOR GAS LINE 4E BOND a' a n E AM - in, GYP. EBARS /�-Uk' B AW 2B GAS LINE THRU BLOCK D1 xALe,la•.r_o. —2X4 SPF 24' O.G. MAX. -- SECURE W/ (2) 12CI NAILS EA. END 2x BLOCKING BETWEEN TRUSSES --PER STRUCTURAL DETAILS - 1/2' THICK, 2 COAT - PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY GAL..V. STEEL TRACK BRACKETS FASTENED TO WOOD JAMB PER PRODUCT GALV. STEEL APPROVAL R a VERTICAL TRACK 1' MIN. BY MAUR SLIDE FASTENED TO ,� TRACK BRACKETS W/ PRODUCT APPROVAL REQ. D1 CORNER BEAD e' CMU SEE STRUCTURAL FOR REINFORCEMENT 2x& P.T. WD ATTACHED TO FILL CELL AS PER PRODUCT APPROVAL REi SEALANT BACKER ROD WEATHER STRIP MOULDING ALL AROUND (BY DOOR MANUFJ OVERHEAD DOOR BY OTHERS GARAGE DOOR JAMBS SCALE: 1 l/2' =1I -0` FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR 005.1.1. ROOF SHEATHING THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE STIFFBACK AT ALL UPRIGHTS— I/J PER STRUCTURAL DETAILS MTL. DRIP EDGE AX- PRE-ENG WD. TRUSS Ax. 2x FASCIA PER r 1 ELEVATIONS PER ELEVATION VENTED SOFFIT CONT. 2x RAT RUN SECURED PER- STRUCTURAL DETAILS WALL SHEATHING SEE ENERGY CODE FORMS FOR THICKNESS AS PER INSULATION R-VALUES SHEET SNI. SECURE EE E RE PER PER ELEVATION FASTENER SCHEDULE ON SHEET SNI. 5/8' GYPSUM BOARD OR I/2' — HIGH STRENGTH CLG. BOARD PRE-ENG. GABLE TRUSS n WEEP SCREED A W WINDOW OPENING 2x P.T. SECURED PER R-4.1 INSULATION ----- 1 STRUCTURAL DETAILS WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS I REFERENCE Reviewed for Code STRUCTURAL Compliance 1x2 P.T. FURRING --- Universal Engineering Sciences STRIPS g 24' O.C. In' GYP. WL. BD. 8' CMU WOOD 5ASE— OL 0'-0' FIN. FLR. ROOF SHEATHING THICKNESS IS ENGINEERED PER ASCE I-16 IN ACCORDANCE WITH FBCR 2020 _[TH EDITION, SECTION R301.1.3 AND 1609.5.1. TYP. WALL SECTION NO OPENING NOTE: METHOD TO BE USED FOR THE 6 1-STORY GABI,III BLOCK WALL INSTALLATION OF ROOF 3/4'=I'-0' UNDERLAYMENT IN ACCORDANCE Di SCALE= WITH FBCR S05.1.1.1 OF THE FBCR 2020 7TH EDITION IS 04 WHICH USES (2) TWO LAYERS OF ASTM D226 TYPE II OR ASTM D4865 TYPE III OR TYPE IV UNDERLAYMENT. Note: WALL FENESTRATION FLASHING PER FBCR '103.4 - Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of water into the wall Cavity or penetration of water to the building structural framing components_ Self -adhered membranes used as flashing shall comply with AAMA -111. All exterior fenestration products shall be sealed at the juncture with the building wall with a sealant Complying with AAMA 000 or ASTM C920 Glass 25 Grade NS or greater for proper Joint expansion and Contraction, ASTM C1Z!81, AAMA 812, or other approved standard as appropriate for the type Of sealant. FlUld-applied membranes used as flashing in exterior walls shall comply with AAMA 114. The flashing shall extend to the surface of the exterior wall Finish. 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591> www.abdesigngroup.com AA #: 0003325 F W W QQ 0 F 4 v r7 W O F A ti SUBDIV. ac LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT# 04321.200 083R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: DETAILS 60 MPH EXP. C ARCHITECT: STATE OF FLORIDA MAR 2 2 "21 MICHAEL C. A 4DERSON AR NO 17305 PRINT DATE: 03 19 21 SCALE: 1/4"=1'-0" SHEET ID 1 B FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER F5CR 905.1.1. ROOF SHEATHING THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE PRE-ENG WD.TRUSS 24' O.C. MAX_ METAL DRIP EDGE—'_� 2x FASCIA PER ELEVATIONS VENTED SOFFIT REFERENCE STRUCTURAL 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY IX2 FIRE -STOP SEE STRUCTURAL Ix2 FIRE -STOP 1/2' THICK, 2 GOAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY IX2 FIRE -STOP FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR'305.1.1. ROOF SHEATHING THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE R PRE-ENG WD. TRUSS---- LEVATION 24' O.G. MAX. METAL DRIP EDGE--` BATT INSULATION REFER TO ENERGY CALCS FOR VALUES 2x FASCIA PER—/ GYPSUM BOARD ELEVATIONS OR 1/2' HIGH STRENGTH CLG. BOARD VENTED - __/ L5/8' FIRE -STOP SOFFIT / R-4.1 INSUL. REFERENCE (y —�— WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS STRUCTURAL i 3/4' T 4 G SUBFLOOR GLUED AND NAILED Id AS PER NAILING n SCHEDULE ui i ER ELEVATION LEVAER;T STRUCTURAL 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY IX2 FIRE -STOP SEE STRUCTURAL 5/8' GYPSUM BOARD OR 1/2' HIGH STRENGTH CLG. BOARD _ E �CLEVATION 1X2 FIRE -STOP R-4.1 INSUL. (v I n�I —I—WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS —,`REFERENCE STRUCTURAL Ix2 P.T. FURRING STRIPS A 24' O.G. 8' CMU J 1/2' GYP. WL. BD. WOOD BASE 1/2' THICK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY IX2 FIRE -STOP R ELEVATION BATT INSULATION REFER TO ENERGY CALCS FOR VALUES m o.H. I 5/8' GYPSUM BOARD TYP. - OR 1/2' HIGH STRENGTH CLG. BOARD k Ix2 FIRE -STOP I- R-4.1 INSUL. 0 1 > Lu I; w � f �W 3/4' T 4 G SUBFLOOR GLUED AND NAILED AS PER NAILING z SCHEDULE O 0 > (- u1 � R Li ELEVATION 77 — - PER LE VATION 5/8' GYPSUM BOARD OR 1/2' HIGH STRENGTH CLG. BOARD R-4.1 INSUL. N Z 0 Q > W ul W Reviewed for Code � Compliance Universal Engineering 91 Sciences Ix2 P.T. FURRING STRIPS ® 24' O.G. 8' GMU 1/2' GYP. WL. BD. WOOD BASE 1A W WINDOW OPENING 1B WITHOUT WINDOW OPENING 2-STORY FIRST[' FLOOR BLOCK SECOND FLOOR BLOCK SCALE: 3/4'=1'-0' -- -- 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 rnml W U w 0 0. W O F Q ti suBDIV. Z LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT# 04321.200 083R1 DdODEL 4EHB 2605- HAYDEN' GARAGE SWING: LEFT PAGE: DETAILS 60 MPH EXP. C ARCHRECT: STATE OF FLORIDA MAR 2 2. 2021 MO-ML C. ANDER^AN AR NO 17305 PRINT DATE: 03 19 21 SCALE: 1 /4"=1' — 0" �' I a TOP: 2X6 P.T.. CENTER OF DOOR HEADER SECURED W/ (1) IR' X Be J-BOLT W/ 4' MIN. EMBEDMENT W/ 2' X 2' X I/8' WASHER 4 NUT OR W/ (2) 1/2' X be ANCHOR BOLTS W/ 4' MIN. EMBEDMENT W/ 2' X 2' X 1/5' WASHER 4 NUT Ix4 P.T. OR 5/42X4' MIN. SECURE THRU FRAME 4 EXTEND 1-114' INTO BLOCK W/ 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN HEAD SIZE 300 MIN. EMBEDMENT 1-1/4' WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING �L-SEGURE 2x4 ONE' FLAT TO BLK T1 W/ MASONRY NAILS. SIDES: 2X6 GARAGE DOOR BUCK SECURED W/ (5) 1/2' X 8' J-BOLT OR ANCHOR BOLTS, W/ 4' MIN. EMBEDMENT, W/ 2- X 2' X 1/5' WASHER 4 NUT. (1) WITHIN 8' OF TOP, (1) WITHIN Be OF THE BTM, (3) EVENLY SPACED. NOTES: ALL ANCHORS SHALL BE IN ACCORDANCE TO MANUFACTURER'S INSTALLATION INSTRUCTIONS WHERE SUCH INSTRUCTIONS ARE MORE STRINGENT GARAGE DOOR 1 BUCK ATTACHMENT D3 eca.e, VV-P-®' 8' CMU In, DRYWALL 1'X4' P.T. NAILER DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +3/4" OR +5/4" nl►INDOW TO BLOCK +3/4" OR +5/4" _ H 2X4: IZI SECURE TO BLOCK W/ 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN W OF EACH END 4 18' O.G. MAX SPACING 2X6: CEM SECURE TO BLOCK W/(2) 3/16' TAPCONS (MIN- SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 1W O-C. MAX SPACING. 2X8: CEM SECURE TO BLOCK W/(2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN Be OF EACH END 4 18' O.C. MAX SPACINGSG, 8' CMU 1/2' DRYWALL I'X4' P.T. NAILER 1/16' O.S.B. X 4' MIN. DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +1 15/16" C 1PINDOVP TO BLOCK +1 15/16" 2X4: IZI SECURE TO BLOCK W/ 2X4: 1311 SECURE TO BLOCK W/ 3AW TAPCONS (MIN. 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH WITHIN 8' OF EACH END 4 18' O.G. MAX END 4 18' O.G. MAX SPACING. NOTE: STRUCTURAL 2X MUST BE SPACING. ON OUTSIDE 4 SECURED 2�, CEO 2X6: ® THROUGH NON-STRUCTURAL SECURE TO BLOCK SECURE TO BLOCK 3/16' TAPCON MIN. 1-1/4' W/(2) 3/16' TAPCONS W/(2) 3/16' TAPCONS EMBEDMENT INTO BLOCK (MIN. SHANK SIZE .145 (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 8' CMU MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END WITHIN Be OF EACH END 8' CMU 4 18' OTC. MAX SPACING. 1/2' DRYWALL 4 18' O.G. MAX SPACING. 1/2' DRYWALL 2X8: ® ❑ I'X4' NAILER 2X8: ® SECURE TO BLOCK ❑ I'X4' SECURE TO BLOCK P.T. P.T. NAILER W/(2) 3/16' TAPCONS POOR CASING W/(2) 3/16' TAPCONS (MIN. SHANK SIZE DOOR CASING (MIN. SPANK SIZE J45 .145 MIN- HEAD SIZE 300 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END WITHIN 8' OF EACH END Or— 4 MAX 18 .C. DOOR JAMB OR WINDOW SPACING. X DOOR JAMB OR WINDOW SPA ATTACH TO 2X PER ATTACH TO 2X PER MANUFACTURES DETAILS. MANUFACTURES DETAILS - NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/4') DOOR JAMB TO BLOCK +1 1/2" B WINDOW TO BLOCK +1 1/2" NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +2 1/4" D)1IINDOW TO BLOCK +2 1/4" 2X4: IZI SECURE TO BLOCK W/3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING 2X6: CEM SECURE TO BLOCK W/(2) 3/I6' TAPCONS (MIN_ SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 8' CMU 4 18' OZ. MAX SPACING. 2X8: ® ❑ I/2' DRYWALL SECURE TO BLOCK I,X4, P.T. NAILER W/(2) 3/16' TAPCONS (MIN. SHANK SIZE .145 DOOR CASING MIN- HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH END 4 10' O.G. MAX SPACING:. DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMS JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +3" E 2X4: CM SECURE TO BLOCK W/ 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH END 4 IS' OZ. MAX SPACING. 2X6: CEM SECURE TO BLOCK WK2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN Be OF EACH END 4 18' O.G. MAX SPACING. 2)(8: SECURE TO BLOCK W/(2) 3/16' TAPCON8 (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 IS' OZ. MAX SPACING. NOTE: STRUCTURAL 2X MUST BE ON OUTSIDE 4 SECURED THROUGH NON-STRUCTURAL 3AW TAPCON MIN. 1-1/4' EMBEDMENT INTO BLOCK B' CMU 1/2' DRYWALL ❑ 1'X4' P.T. NAILER DOOR CASING 2ND 2X SECURE TO STRUCTURAL MEMBER W/l2)126 WITHIN Be OF EACH END 4 W TO Be O.C. MAX DOOR JAMB OR WINDOW ATTACH TO 2X PER NOTE: SHIM AS NEEDED TO PLUMB MANUFACTURES DETAILS. JAMB (DO NOT EXCEED 1/4') DOOR JAMB TO BLOCK +3" F A 2X4: CM SECURE TO BLOCK W/ 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 2Xb: CEO SECURE TO BLOCK W/(2) 1/4' TAPCONS (MIN SHANK SIZE 145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN Be OF EACH END 4 IS' OZ- MAX SPACING 2X8: SECURE TO BLOCK W/l2) 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN Be OF EACH END 4 18' OZ. MAX SPACING. J H � 8' CMU ❑ 1/2' DRYWALL 1'X4' P.T. NAILER 1/16' OS.B. X 4' MIN. DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/4') DOOR JAMB TO BLOCK +3 7/16" G IIINDO'W TO BLOCK +3 7/16" 2X4: SECURE TO BLOCK W/ 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN, EMBEDMENT 1 1/4') WITHIN W OF EACH END 4 18' O.G. MAX SPACING. 2X6: CEO SECURE TO BLOCK W/(2) 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 2X8: MM SECURE TO BLOCK W/(2) 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN_ HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN W OF EACH END 4 18' O.G. MAX SPACING. NOTE: STRUCTURAL 2X MUST BE ON OUTSIDE 4 SECURED THROUGH NON-STRUCTURAL 3/I6' TAPCON MIN. 1-1/4' EMBEDMENT INTO BLOCK- 1 141 8' CMU - I/2' DRYWALL ❑ I'X4' P.T. NAILER a I' PS. X 4' MIN. � DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/40) DOOR JAMB TO BLOCK +3 3/4" H 5P 211W TO BLOCK +3 3/4" E�m As Reviewed for Code Compliance Universal Engineering Sciences CMU IQ O0% is DRYWALL IX FURRING RIP 2XI0 TO DOOR FRAMING HOLD FLUSH TO INTERIOR FACE OF DRYWALL ENTRY DOOR BUCK (]./�REQUIREMENTS 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www. a b d es i g ngrou p. co m AA #: 0003325 00 F W x v W 0 F 0. U W A h A z sysDIV. & LOT- CREEKSIDE PHASE 2 LOT #83 PROJECT* 04321.200 083R1 MODEL• 4EHB "2605-HAYDEN' GARAGE SWING: LEFT PAGE: DE TAIL ) 60 MPH EXP. C 00 ARCHITECT: STATE OF FLORIDA MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 rsur" DATE: / 03 19 21 i SCALE: 1/4"=1'-0" 1 SHEET D3 i 2194 HWY A1A. SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 E. W y r4 O U W 0 h 4 F A F ti SiJHDIV. 8e LOT: CREEKSIDE PEASE 2 LOT #83 PROJECT# 04321.200 083R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: WALL ASSEMBLY DETAILS 60 MPH EXP. JC ARCHffECT STATE OF FLORIDA MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT 2119 DATE: 03 / / SCALE: 1/4"=1'-0" SHEET LEGEND DRAINAGE PLANE (WRS LATER *1, STUCCO WRAP) WRB LATER *2 (FORTIFIBER — — — — — BUILDING PAPER) METAL LATH X—X—X—x STUCCO WOOD OR -1/16" ZIP WALL SHEATHING SELF-ADHESIVE FLA5HING NOTE - METAL LATH: LATH TO BE PER SECTION R-I03.1.1 / ASTM C-841-14a, MIN. 2.5 LSS. PER Sa. WARD (UTILITY' OR NOMINAL LATH DOES NOT MEET 8FEGIFICATION5) FINISH 6" SELF ADHESIVE OVER TOP E SIDES SELF FLASHING UNIT PREMANUF. DRYER VENT CAP (SET IN CONT. SEALANT) SEALANT g TOP E SIDES YER VENT ( BLOC] BUILDING PAPER OVER 'QUICK FLASH' PIPE THROUGH WALL 6" SELF ADHESIVE — FLASHING (INSTALL PER MANUF. SPECS.) BUILDING PAPER UNDER 'QUICK FLASH' A VENT PENETRATION SCALE: N.TS. ELEC. METER FIELD VERIFY LOCATION AREA TO RECEIVE STUCCO SCRATCH COAT 4 1 COAT OF PAINT W/BACK- ROLL PRIOR TO ELEC. METER INSTALLATION C. METER FIELD .IFY LOCATION APPLY STUCCO SCRATCH GOAT AND ONE (1) LAYER OF PAINT PRIOR TO INSTALLING ELEC. METER CAVITY TO BE FILLED WITH RIGID POLYMERIC ISOCYANOTE-POLYBLEND FOAM /n�_�r A rti ir"n 7R .SIMILAR) APPLY A SILICON BASE SEALANT AT POINT THAT ELEC. WIRE PENETRATES ;O SCRATCH COAT LARGER THAN THE ELEC. METER CAN OR METER GAN COMBO OR METER CAN AND DISCONNECT O ELECTRICAL CONDUIT PENETRATION WOOD SHEATHING WRB LAYER *I, STUCCO WRAP WRB LAYER 02, FORTIFIBER 10/ BUILDING PAPER METAL LATH WOOD -1/5' TEXTURED CONSTRUCTION �-�FINISI-I a WOOD FASTEN TO WOOD STRUCTURAL 13' GMU MEMBER a In OjC. MAX Ye' TON MID -WALL 1 �, WEEP SCIREED = zQ 6' WIDE STRIP SELF ADHESIvE FLASHING, CLEAN MASONRY BEFORE APPLYING TEXTURED FINISH a MASONRY HORIZONTAL WEEP SCREED (FRAME TO BLOCK) all WRB LAYER *I, CUT OPENING IN STUCCO WRAP APPROVED HOUSEWRAF, At FOR BOX INSTALLATION SCUT `X' INTO TUCCO WERAP I MEMBRANE FLLASNING I �, .I APPLY SELF -ADHERING WOOD SHEATHING I IMEMRANE FLASHING OVER BBOX AND OVER APPROVED WRB Reviewed for Code LAYER *1 Compliance 5 T� S T F �^ Univerz MSci nceiseering APPROVED HOUSEWRAP BELOW CUT SUCH THAT NO MEMBRANE ENTERS BOX, APPLY TO FACE EDGE APPLY E-Z BEAD OVER 60 MIN GRADE 'D' FELT -PROVIDE SEALANT AT ALL JOINTS AND INTERSECTIONS ST f= #3 WRB LAYER *I, STUCCO WRAP Ea APPLY 60 MIN SELF —ADHERING GRADE 'D' FELT MEMBRANE FLASHING OVER SELF -ADHERING FLASHING OVER APROVED HOUSEWRAP WRB LAYER *2, FORTIFIBER BUILDING PAPER 5T #4 ELASTOMERIC COATING OVER STUCCO/ G.V. FINISH (SEE TYPICAL WALL SECTION) METAL LATH 5T I*F7;i 5T E F **(o ELECTRICAL RECEPTACLE 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W y U 0. w 4 F A BUBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT# 04321.200 083R1 MODEL 4EHB "2605—HAYDEN" GARAGE SWING: LEFT PAGE: WALL ASSEMBLY DETAILS 60 MPH EXP. C ARCHITECT= STATE OF FLORIDA MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 rrcaav • a DAT03 19 21 E/ SCALE: 1/4"=1'-0" SHEET LEGENT DRAINAGE PLANE (UJRB LATER #1, STUCCO UJRAP) UJRB LATER #2 (FORTIFIPER — — — — — BUILDING fi=APER) METAL LATk x x x x STUCCO WOOD OR 1/16" ZIP WALL SkEATNING ---- SELF—AC)kE51VE FLA5k1NG z 1/211 CORNER BEAD (FASTENER & SPACING al C. N ' CMU 1/2" THICK, 2 COAT CEMENT _j PLASTER APPLIED 148 CORNER D IRECTL`r' TO MASONRY BEAD 0) BLOC][ Reviewed for Code Compliance Universal Engineering 91 Sciences 2194 HWY A1A. SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www. a b d es i g ngro u p. com AA #: 0003325 F rA W v W may.. 0 F 0. V to F A c 0 w SUBDIP. & LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT# 04321.200 083R1 MODEL: 4EHB "2605—HAYDEN" GARAGE SWING: LEFT PAGE: �l 41 WALL ASSEMBLY DETAILS 60 MPH EXP. C ARCHFrECT STATE OF FLORIDA MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT 03 19 21 DATE: / / SCALE: 1/4"=1'-0" SHEET I I I 11 1 " 2xro SUB -BAND W/1"x4" NOTCH tv END, WRAPPED IN PEEL 4 STICK DRIP EDGE ►\\ 11 1/8" TEXTURED I �\ FINISH 10 WOOD I \ 1/2" TEXTURED 1 FINISH e CMU / \ METAL FASCIA + WRAP Ya" FROM \ STUCCO, 1" FROM \\ WOOD WALL 1 EXTERIOR WALL \ (FRAME OR CMU) ,\ �\ NOTE: NOTCH FOR 2X6 1 SUB BAND ONLY N. AN A METAL FASCIA WRAP 2X6 SU13 BAND-1= —ROOF KICK OUT REMOVED \\ FOR CLARITY .ROOF DECK (BEYOND) \art DRIP EDGE, 1" OFF WALL VNOT INTO STUCCO) 11/5" TEXTURED FINISH 6 / WOOD, 1/2" TEXTURED FINISH m CMU / ��2xro SUB -BAND W/1"x4" NOTCH 6 END, WRAPPED IN PEEL d STICK METAL FASCIA WRAP 1" OFF WOOD WALL. SUB BAND 2" OFF WOOD WALL -1/8' TEXTURED FINISH o WOOD, 1/2' TEXTURED FINISH a CMU METAL LATH WOOD SHEATHING: OR CMU WRB LAYER 01, STUCCO WRAP (FRAME ONLY) WRB LAYER 02, FORTIRBER BUILDING: PAPER (FRAME ONLY) ROOFING: CEMENT DRIP EDGE METAL KICK OUT NOTE: IF ZIP SHEATHING 5, PLEASE SEE MANUF PROCEDURES PRE-ENG'D TRUSS TO BE CUT 6 WALL LINE TO AVOID CONTACT W/TEXTURED FINISH 2 "x4"x4' -m" SCABBED TO TRUSS W/126 NAILS roll-8" O.C. MAX. 2x SUB -BAND W4V2"x4" NOTCH 'Q END METAL FASCIA WRAP DRIP EDGE EXTERIOR WALL (FRAME OR CMU) SUB BAND DETAIL C� WALL SUB BAND DETAIL OP WAL W/KIC K-- O U'I' FRAME OR CMU FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. Y4" ABOVE BOTTOM OF DRIP EDGE 2x SUS -BAND W/tY"x4" NOTCH a END, WRAPPED IN PEEL 8 STICK *ROOF CEMENT a ROOF EDGE OMITTED FOR CLARITY <�r FRAME OR CMU WALL KICK -OUT FLASHING FELT PAPER DRIP EDGE (REFERENCE POINT ONLY FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. Y4" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/tY"x4" NOTCH -8 END, WRAPPED IN PEEL 8 STICK *ROOF CEMENT -8 ROOF EDGE OMITTED FOR CLARITY 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 3, 1-802-3591 www.aba esigngroup.cum AA #: 0003325 00 F N U w 0 Q G a E; A siumnv. & LOT. CREEKSIDE PHASE 2 LOT #83 PROJECT# 04321.200 083R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: WALL ASSEMBLY DETAILS: SUB -BAND 60 MPH EXP. C ARCHrrECT MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT 2119 DATE: 03 / SCALE: 1/4"=1'-0" SHEET WAS 39'-8" 27-10„ 101-0.1 1'-10.; oo uu FFM-12X18 _ o 100 001 m 0D I oo X r I i o 4" CONC. IX LL SLAB LL li LOMU c L�j.o -.1 L L rE u � ° —4------1— —FM-16x18 ---------- I 2.1 1.1 2'-8" 15'-4" 1 V-8" 10'-0" I 00 I� CV. 0101,zo z co X r I' IT P OF TO T rI SLAB b N N CP 0 Lo 0 co iv V W SLAB io 0 11'-10" 7-5" 20'-5" . *CW-12x"12 �— 11 R 8 Z_ J II 1.1 1.1 C)F-21H•x24 Cr II O c' CWC-12x12 O OD 11< III (p N — N O 2 11 v �4 VC f 00 CSJ LL �N UP TO 2ND FLOOR u) I v ay CHASE (FIELD VERIFY I L�. EXACT LOCATION) 8 ii W �1 5 3'-0" 11 tl 9'-4" 2'-8" 9"-0,. 9,_3" 9,-5„ N X 1 P w -j IU 00 #3 TRSER STEEL 1.1 C@ 24" O.C. MAX 2 U) ao - co 1.1 N I N i\j � 0'-0" FIN. ELEV. xo FIN. CONC. SLAB jj LL—FM-16x18 4 4 �I E] Um=111I i,I 1'-03' 5'v 3' 11„ 9' 8" 2' 10" 1.1 16'-0" 1.1 2 — FM-16x18 J o — - - - N TI 0 0- r LL I7—FM-12x18 71 20'-4" 1-4" 5 4' '-4" -: 10'-01, 4„ 21'-8" 18'-01, 39'-8" i FOUNDATION PLAN SCALE:'1/4' = 1,_0" O OP zo Cl) Y b. O Ov N o OP n J w C? F- co d �O F- I 0 N s FOUNDATION NOTES 1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR COMPACTING REQUIREMENTS. 2. TOP OF FINISHED SLAB SHALL BE +44% 3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED OTHERWISE. 4. REFERENCE ELEVATION F-0'4SEE SURVEY PLOT FOR NAVD. 5. PROVIDE A (-,'OMPLFTE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS ESTABLISHED BY THE FLOF3IDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. 6. PROVIDE ISOLA [ION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: PROVIDE 1 2" FELT PAPER AT THE JOINT. 7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL DRAWINGS. 8. SEE ARCHI I FG T I II ;AL A iAWINGS FOR THE ORIENTATION OF THE BUILDING, 9. WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE WINDOW. DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS AND WITH THE MANUFACTURES SPECIFICATIONS, 10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. 11.11 INDICATES 45 BAR. OINDICATES'#6 BAR,OINDICATES #7 BAR VERTICAL REINFORCING; BAR IN CELLS FILLED WITH GROUT. ENDS OF REINF. BARS SHALL BE HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 900 HOOK. BARS f,HALL BE PLACED AS SHOWN IN HE PLANS. 12, SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = 30", #6 =36" ), AND REINFORCING SHALL BE CONTINUOUS. 13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS BEEN DELETED UNL ESS NOTED OTHERWISE. 14, VERTICAL REINFORCING IN CMU SHALL BE #5'SAS SHOWN ON THIS PLAN, UNLESS OTHERWISE NOTED IN I HE PLAN. ONE REINFORCING BAR SHALL BE: A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS 15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH TMS 4021602-16, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. CONSTRUCTION SHALL BE IN ACCORDANCE WITH TMS 402/602-16, USING: F'm = 2,000 PSI, TYPE "M" OR"S" MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN RUNNING BOND. 16. WIRE WELLIFD MF:_ H LOCATED IN THE MIDDLE TO UPPER -3 OF SLAB SUPPORTED T-0" OTC MAX. SEE PLAN FOR WWM SIZE. INSPECTOR NOTE: 1. STRUCTURE WAS DESIGNED BASED ON THE'2020 FLORIDA RESIDENTIAL BUILDING CODE, RESIDENTIAL, 71h EDITION SLAB SCHEDULE SLAB IIIICKNESS REINF REMARKS 6x6 W1.4xW1.4 OVER GENERAL I I I'2" 6 MIL VAPOR COMPACTED FILL BARRIER FOOTING SCHEDULE PROVIDE_ CORNER BARS, SAMI SIZI- OUAN I ITY AS BARS IN FOUNDATION, WITH 30" LEG EACH WAY. MARK WIDTH I ENGTLI THICKNESS BOTTOM REINF. TOP REINF. T.O.F. -- _ — - ' SHORT LONG FM-12x18 12" CON INUOUS 18' (2) #5's I - (+)0' 0,, FM-16xl8 16" CONTINUOUS 18" (2) #5's - (+)0"-0', FM-20xl8 20" CONI INUOUS 181, (2) #5's - (+)0"-0" FMC-16xI8 16" CON T INUOUS 18" (2) #5's - VARIES CW-12xl2 12" SFF PLAN _ 12" (2) #51s - (+)0"-0" CWC-12x12 12" SFF PLAN 121, (2)#Ss - VARIES F-24x24 24" 24" 12" (2) #5's' (2) #5's - (+)0"-0" TE-1 8" SI I PLAN 8" (1)#5's (_)0^_411 Reviewed for Code Compliance Universal Engineerinel Sciences NOTE: WELDED WIRE MESH A VERTICAL RE BAR NO SHOWN FOR CLARI I Y #3 TRANSFER STEEL a 24 ()JJ MAX ON 1 1,2" SECURE CHAIRS @ FOUNDATIONSI AB A WIRE IIED A/G SIMPS❑N WB TO CONTINUOUS FOOI F R S Lr I I STRAP TO CONC. W/ UNIT ROLL STRAP OR (2)-3/16'X2' EQUAL 2 EACH TAP —CONS CORNER OF _ - L _B UNIT TOP OF SLAB CONC• SECURE STRAP TO SUPPORT #s w 1 I 7 Cl InIRs SLAB UNITS W/ (2) #Bxl 1/4 SHT MTL SCREWS A/C CONNECTION TO PAD DETAIL TRANSFER STEEL INSTALLATION SCALE: 3r4"=V-0" 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH. FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W U 0 F 0. W 4 A it sLJBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT* 04321.200 083R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: FOUNDATION PLAN 7 60 MPH EXP. C ARCH x _CT: TE OF FLOF I+ MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 1 DATE 03/19/21 SCALE: 1/4 =1 -0 SHEET S I J ' IP m t W^ e Z SEE I STEEL REINFORCING IN GROUTED CELL SEE PLAN FOR SIZE AND 0- SPACING REQUIREMENTS Lu m 00 J oC co _ z 8" CMU WALL O to � co a - r a SLAB SCHEDULE EXT. PORCH SLAB 4" CHAMFER (1-STORY) W/ 1/2" ISOLATION 6" CHAMFER (2-STORY) JOINT (WHERE • • APPLICABLE) z SEE SCHEDULE FOR WxD, BAR SIZE N AND BAR QUANTITY BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" EXTERIOR MONO -FOOTING ' SCALE: 3/4"= V-0" 0 co LLARD LAP P PLATE A MIN. OF 48" AND N L W/ 16d COMMON NAILS, 2- OWS,4" O/C BTM. LAP TO OC ROVER STUD 2x4 OR 2x6 WOO BEARING - WALL W/ SYP No 2 TUDS SEE PLANS FOR SPACIN SINGLE BTM: PLATE TO BE PT. PROVIDE DBL. TOP PLAT TOP OF SLAB 2"CAPPED GALVANIZED PIPE W/FLANGE pa BASE SECURE FLANGE TO SLAB W/(4) 1/4" X21/4" TAPCONS ®1 M SCALE VERIFY HEIGHT OF WALL W/PLAN PROVIDE BLOCK7ETO SECURE BT. P S 10d SONRY NAIL O/ T GERED. ,A T L METAL C N TORS NOT RED WHEN NO FT IS PRESENT. SEE SLAB SCHEDULE ® SEE SCHEDULE FOR WxD, BAR SIZE D BAR QUANTITY D9INTE R FOUNDATION OD WALL SCALE: 3/4"=1'-0" (NO P L I FT) z_ " STEEL REINFORCING IN GROUTED CELL SEE PLAN FOR SIZE AND } SPACING REQUIREMENTS w m U Lu � Q ir 8" CMU WALL o - Z co o- �- T SEE SLAB SCHEDULE TOP EXT. PORCH SLAB 4" CHAMFER (1-STORY) W/ 1/2" ISOLATION 6" CHAMFER (2-STORY) JOINT (WHERE • • SEE SCHEDULE APPLICABLE) z FOR WxD, BAR SIZE AND BAR QUANTITY (V EXTERIOR MONO -FOOTING GARAGE SCALE: 3/4"=V-0" O' 0- I co NEW.REINF. BAR O SECURED W/2-PART a g EPDXY. MIN. EMBED 8", UNO p FOLLOW ALL MANE. = SPECIFICATIONS FOR = m I USEAND 00 41 4 PREPARATION OF Z HOLE. LJ J' M o Q) Q 4" CHAMFER (1-STORY) 6" CHAMFER (2-STORY) ADDING BAR TO MONOLITHIC FOUNDATION LE: 3/4"=V-0" POURED LI N P. • OU ) ro,;, 8" CMU F L C P.) U' 2X W L F MI 1/ " DIA. N STB2 BOLTS 5" MIN UM E EDMENT INTO GRO ELL, 4" FROM ENDS AND 16" O.0 RTICALLY MAX INTER R FRAME BRG W L TO BL(O K WALL CONNECTION 11 SCALE:3/4"=V-0" 30" MIN. EACH WAY I- - MONOLI [I IIC FOOTING Fr �.; ]—FM— CORNF H HAHS, SAME SIZE AS LARGER BAR 1N F OUNI )A I II )N WITH 30" LEG EACH WAY AI ALI CNANGES IN DIRECTIONS SU 1 HA I I HF S I F EL REINF. IS CONTINUOUS MATCH AMOUNT OF CONTINUOUS BARS ILL _ CONIINIIOIIS SI.FEL MONOLITHIC F.L)OI INc HL INI OHCEMENT SEE SCHEDULE WHEN TRANSITIONS ARF I't f ROM FOUNDATIONS HAVING DIFFERENT NUMBER OF CON INUOIJS BARS PROVIDE THE LEAST NUMBER OF BARS (ie 2 To 1 3. PROVIDE 2 BARS). LINO MONOLITHIC FOUNDATION CORNER BARS DETAIL z STFFI RFINFORCINGINGROUTED CELL SEE PLAN FOR SIZE AND SPACING REQUIREMENTS O } oc 00 U V J cc U) - Z 8" CMU WALL O co 0 M SEE SLAB SCHEDULE EXT: PORCH SLAB 4" CHAMFER (I -STORY) W/ 1/2" ISOLATION 6" CHAMFER (2-STORY) JOINT (WHERE • APPLICABLE) Z MATCH STEEL 2 REINFORCEMENT 6" PVC CHASE N PER SCHEDULE THRU FOOTING �� -SEE SCHEDULE FOR WxD BAR SIZE FOR NRY ISET EV: RECESS AROUND GARAGE DOOR OPENING SCALE: 3/4"=V-0" I.Al' IOPPIA]EAMIN .OF48"- ANU NAIL W' 16d COMMON NAII S. 2-ROWS, 4" O/C B-TM. I_AP 10 OCCUR OVER STUD Px4 (Al 2v6 WOOI) BEARING - WAI I W RYP No 2 STUDS SEE PLANS FOR SPACING. SINGLE BIM PI All TOBE PL PROVIUF f)RI TOP PLATE —07OIr U" P OF SI AB +- 0'-0.. _ TOP OF SLAB BAR SIZE 48 BAR DIA #3 18" #4 24. #5 30" #6 36"— #7 42' AND BAR QUANTITY PVC CHASE S�ITHRUFOOTING SCA[[ 3`4"-I' 0" VERIFY HEIGHT OF WALL W/ PLAN PROVIDE BLOCKING SECURE BT. PLATE TO SLAB W/10d MASONRY NAIL 16" O/C STAGGERED. / ADDITIONAL METAL CONNECTORS NOT REQUIRED WHEN NO UPLIFT IS PRESENT. Li rSEE SLAB SCHEDULE I EQ. EQ. SEE SCHEDULE FOR WxD, BAR SIZE AND BAR QUANTITY INTERIOR CURB FOUNDATION WOOD WALL SCALE. 314"=V-0" (NO UPLIFT) Reviewed for Code Compliance Universal Engineering Sciences NG REINFORCEMENT PER SCHEDULE 2194 H WY A1A. SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com 11114 AA #: 0003325 F W U W a a U 4 _- F A L��'d � SiT]BDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT# 04321.200 083R1 MODEL: 4EHB F "2605—HAYDEN" 6iI%AGE SWING: a, LEFT PAGE: DETAILS Ai )I.60 MPH EXP. Cl ARCHrrECT: STATE OF FLORIDA rXII?l I) MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 ';PRINT SATE: 03/19 /21 ;SCALE: 1 /4" =1' — 0" SHEET C S l' . 1 O C7 N a N 00 _I, II -V _- -- -'-4/ FIRST FLOOR DOWEL PLAN SCALE: 1/4" = 1'-0" 0 W Q� N Reviewed for Code I Compliance hu Universal Engineering Sciences F W U WW O F 0. U W Q F A Ci r r VBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT# 04321.200 083R1 MODEL: 4EHB "2605— HAYDEN" GARAGE SWING: LEFT PAGE: FIRST FLOOR DOWEL PLAN 460 MPH EXP. C ARCHrrECT- STATE OF FLORIDA - MAR222221 MICHAEL C. ANDERSON AR NO 17305 FPRINT DATE: 03 19 21 SCALE: 1 /4"=1' — 0' SHEET S1.2 i i. o- TIE VERTICAL REBAR TO HORIZONTAL Z REBAR W/ 10" HOOK : GROUTED BOND BEAM cy VARIES PER ELEV. r _ -.- (V T Q O m co ,^ CLEAN OUT REQUIRED FOR INSPECTION ..0'-0" FIN. ELF. TIEERTICAL REBAR TO HORIZONTAL REBAR W/ 10" HOOK d a a Z X O CO U HORIZONTAL/VERTICAL BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" REINFORCING 1 SCALE: 3/4"=V-0" ww I 0 a NEW REINF. BAR O Cr SECURED W/ 2- PART a I EPDXY. MIN. EMBED ¢ 6", UNO Q FOLLOW ALL MANE. = Q U) E SPECIFICATIONS FOR = USE AND mPREPARATION OF z 00 HOLE. Lu o ° o— �QQ a ao .a STEEL REINF. OF BOND BEAM ADDING BAR TO 4 BOND BEAM SCALE: 3/4"=V-0" OFFSET METHOD HORIZONTAL/VERTICAL REINFORCING SCALE: 3/4"=V-0" CONTINUOUS METHOD BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" LEV. ns RARS [Fill 8" I,-0" I 0 CMU UNIT DIMENSIONS ; ARE NOMINAL SIZES •`� MASONRY SYMBOLS 3 SCALE3 4"-1'-0" kyReviewed for Code Compliance Universal Engineering Sciences 2194 HWY A1A, SUITE 301' INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www. a b d es i g ngrou p. com AA #: 0003325 f7EI3Iv ae T: CREEKSIDE PHASE 2 LOT #83 I ..� F' ROJECT# 04321.200 083RI k`, 1�1AO]DEL: 4EHB "2605—HAYDEN" C GARAGE SWING: I AFT ?AGE - DETAILS M. ltil 1EI1ER ; gym,; , 41:. ARCHTEC"r- STATE OF FLOMIDA N, MAR 2 2 2021 �MICHAEL C. ANDERSON r. AR NO 17305 .PRINT DATE: 03/19/21 SCALE: 1/4"=1'-0" SHEET g S1.2 A FRAMING NOTES: 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9) 10d x 1 1/2" HDG NAILS. CONCRETE TO WOOD FLOOR`, SIMPSON LTA2 W/ (8) 1 Od x 1 1/2" HDG NAILS, WOOD TO WOOD: SIMPSON H1OA OR LGT2 W/ 1Od x 1 1/2" HDG NAILS, FILL ALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, CONNECTERS ARE TO BE GALVANIZED. 6. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE CONCRETE LINTELS. 7. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS. 8. LINTELS SHALL HAVE 4" NOMINAL BEARING (4'). 9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL. 10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF,.POWDER ACCTUATED FASTENER, ZF 72 P8S36, .177" ° x 2 7/8" LONG, WITH WASHER @ 16" O.C. 11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 12. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. 13. ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. HEADER SCHEDULE MARK SIZE 8 REMARK DESCRIPTION (2) 2X8 BEAM SCHEDULE INDICATES OPENING BELOW / T.O.B. = TOP OF BEAM / B.O.L. = BOTTOM OF LINTEL / T.O.A. =TOP OF ARCH / T.O.S = TOP OF SLAB ABBREVIATIONS E.E. = EACH END, O/C = ON CENTER, F.E.S. = FROM EACH SUPPORT, T.O. = THROUGHOUT MARK DESCRIPTION (psi) WINE' REINFORCEMENT STIRRUPS REMARKS BTM. TOP MID SIZE SPACING BBi MASONRY 3000 8x16 — (1) #5 (1) #5 N/A — GROUTED SOLID BB2 MASONRY 3000 8x8' — (1) #5 — N/A — GROUTED SOLI D SEE SHEET S2.2A FOR SAFE LOAD TABLES 8F32-1 T/1 M/0B UNO, PROVIDE BB1 WHERE TRUSSES BEAR TOP OF WALL EL. 10'-0" ♦ 8F16/1T/1M/0B I1' 0 1 ♦♦ BB2 @ 8'-8" ,I 1 1 ♦ 3- SIDES I 1 - 1m --% GT- m1 1 � �% �� 1 1 LL 1 ° 1 1 a0 1 00 1 8F32-1 T/1 M/0B 8F40-1 T/1 M/OB S2 1 U 8 F2-1T/1M/0B 8F32-iT.%1M/0B___ REHM GT 1 ♦,♦ of ♦ ri 8F42(MIN)-1T/1M;1B �♦ILL L1 FINISHED GARAGE SLAB 8F16 1 � 1 1T/OM/08 1 8F16/1T/0MOB 8F16)1T/0M/0B FIRST FLOOR LIFT BEAM PLAN SCALE: 1 /4" = 1 `4' Reviewed for Cod€ Compliant.@ cm Universal Englnwng Scienoex 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 �' W N 03 rh U N 0 F 0. w 4 I. N J DI WT- CREEKSIDE PHASE 2 LOT #83 PROJECT# 04321.200 083R1 MODEL 4EHB "2605—HAYDI(N" GARAGE SWING: LEFT PAGE: FIRST FLOOR LIFT BEAM PLAN AND NOTES 160 MPH EXP. C mmommmposo ARCHITECT STATE OF FLO1D LEC. AVDIE OR N1730 PRINT DATE: 03 19 21 SHEET S 2 a #5 CORNER BAR W/ 30" LAP FOR EACH COURSE OF BOND BEAM VERTICAL REBAR W110" HOOK #5 BAR IN BOND BEAM OPEN FACE SHELL SO AS TO ALLOW BENT BAR TO BE PLACED IN UPPER AND LOWER BOND BEAM CORNER REINFORCING OF BOND BEAM SCALE: 3/4"=1'-O" SINGLE BOND BEAM AT HIGHER ELEVATION SINGLE BOND BEAM AT LOWER ELEVATION #5 BAR BENT AS SHOWN #5 MIN. REQUIRED IN EACH CELL HOOKED IN TOP BOND BEAM W/ STANDARD ACI HOOK CORNER BARS 3 AT CORNER STEP SCALE: 3.r4"=1'-0" NOTES TO THE INSPECTOR/CONTRACTOR 1. PLACE LINTEL ACROSS TOP OI OPENIHG. 2. IF BOTTOM STEEI IS RLOUIPI- D PLACI 1t5 BAR IN LIN I EL. 3. PLACE MASONRY UNITS AS HFOUIHI 1 ) TO ACHIEVE I I IF REQUIRED BEARING PLACE STEEL HEIGHT. REINFORCING (1-2) 4. THE LAST COURS[l WILL RP A BONI) RI AM WITH (1 ) W, BAR CONTINUOUS AHOUNI) AS DEPICTED HEREIN. STRUCTURE. A DOUBLE BOND BC AM MAY BE SPECIFIF 1) SO THAT THEN THE I_As I TWO COURSES ARE BOND BEAMS WHH A #5 BAR IN EACH COURSE. 5. SHOULD THE DOUBLE BOND BLAM COINCIDE WITH A I INTEL THE BOTTOM COURSE OF BOND BEAM IS OMI I TED AND A LINTEL IS PI ACED. THE STEEL REINFORCING FOR IHE BOTTOM BOND BEAM IS TO BF CONTINUOUS THROUGH I HL TOP OF THE LINTEL_ 6. UNO COMPOSITE MASONRY REAM IS 1 LOBE NOT LF SS THAN 16" DEEP. 8x16 DRI BOND BEAM W 111 05 BAH 4 EACH COURSE Y�� 8x8 BOND BEAM — -� � I OR OF • FQQ�� F W II (1) #5 BAR • ll- BOND BEAM �- = FILLE D W! GROUT U = UNFILLED GROUT SOLID FROM B S1X� NOMINAL LINTEL TO TOP OL BOND WIDTH # OF #5'S, IN 2ND BOND BEAM COURSE BEAM. IF FILLED I INTEL. 16-1 T/ 1 M/0 B LINTELRE A' T#COBNNCCRL TE NOM_ice HEIGHT L LENGTH OF BAR - WIDTH OF #OF#5'S,TOP OPENING 2" IT IS THIS ENGINEER'S INTENT BOND BEAM COURSE OR THAT XFXX - 1T/1 M/OB INDICATES A DOUBLE BOND BEAM — # OF #5'S, BOTTOM 8x8 PRE CAST CONCRETE AND XFXX - 1T;OMrOB INDICATES A SINGLE BOND BEAM PLACED IN LINTEL I IN1 EL. W:'OS TELL (LI) REFER IT IS THIS ENGINEER'S INTENT TO PLAN FOR LOCATIONS AND XUXX - 1T/1 M/OB INDICATES A DOUBLE BOND BEAM ABOVE UNFILLED LINTEL AND XUXX - 1T,-0M/08 INDICATES A SINGLE BOND BEAM ABOVE UNFILLED LINTEL WINDC PRE -CAST WINDOW SILL TYPICAL MASONRY WINDOW SILL CONSTRUCTION d 1 N8" 11#5 BOND D BEAM TYP.8"x16" BOND BEAM /_ 8" 4 _0 1 OP "I OPF MASONRY BD EAM_ DESIGNATION SGALF: 3!4"=1'-O" TOP OF OPFNIN(i SINGLE #5 CORNER I BAR, 30X30 TURNED UP OR TURNED DOWN INTO - STEEL REINF. OF S:, FILLED CELL BOND. BEAM PROVIDE #5 BAR STEEL REINF. OF AT EACH SIDE BOND. BEAM OF ELEVATION CHANGE CHANGE IN ELEVATION OF BOND BEAM SCALE: 314"=1'-O" WOOD SECTION FASTENER SPACING d„ -2" MIN. 2 -" MAX - 2,1" MIN, 9" MAX (212x4 s -1 MIN, 2 1' MAX P1-2' MIN, 2-L" MAX d„ =2" MIN, 2 1," MAX S.. -- 2 �41" MIN, 9" MAX (2) 2x6 s -14" MIN, 2 �' MAX' oo - 4" MIN, 2 z" MAX d., -2" MIN, 2 a" MAX - 2 4," MIN, 9" MAX (2) 2x8 s-1 4" MIN, 2 2" MAX' P,I - '" MIN. 2?" MAX 1.411ST HAVE 2 OR MORE LONGITUDINAL ROWS OF NAILS DOUBLE STUD W/ 10d NAIL ATTACHMENT Revigwit5fflj %Ij' B& Unly 1`041 ETigipwFIK Sciences NOTE: • ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES OF THE COLUMN • ALL NAILS PENETRATE ALL LAMINATIONS AND AT LEAST 1 4" OF THE THICKNESS OF THE OUTERMOST LAMINATION WHERE: de = END DISTANCE s;, = SPACING BETWEEN ADJACENT FASTENERS IN A ROW si = SPACING BETWEEN ROWS OF FASTENERS e;i = EDGE DISTANCE L " / SCALE: N.T.S. 2194 H WY A1A. SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W D3 U W 0 F U Q F A 4 8 13IV & LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT* 04321.200 083R1 MODEL 4EHB "2605—HAYDEN" GARAGE SWING: LEFT PAGE: DETAILS 60 MPH EXP. C ARCHffECT: STATE OF FLOPoDA MAR 2 2 2021 MKAAAEL C. ANDERSON AR NO 17305 PRINT DATE: 03 19 21 SCALE: 1/4"=V-0" SHEET S2. 1 A "LOTT'S CONCRETE" / "CAST-CRETE" / "QUALITY' SAFE LOAD TABLES SAFE GRAVITY LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS T SAFE ':LATERAL LOADS FOR SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS SAFE LOAD - POUNDS PER LINEAR FOOT SAFE PL LFOAD SAFE LOAD - POUNDS PER LINEAR FOOT TYPE LENGTH SUS 8/8-OB /16-1T/06 /20-1T/0B /24-lT/OB /28-1T/013 /32-1T/0B TYPE LENGTH 8/8 PLAIN 8/8 SOLID TYPE LENGTH 8/8-1T 8/16-1T 8/20-1T 8/24-1T 8/28-1T 8/32-1T 8/8-1B 8/16-1T/1B /20-1T/1B /24-1T/16 /28-1T/1B /32-1T/1B 8/8-2T 8/16-2T 8/20-2T 8/24-2T 8/28-2T 8/32-2T T-6" PRECAST 1436 952 3114 4217 5321 6426 7531 3'-6" PRECAST 689 1024 3'-6" PRECAST 1569 3524 4394 5263 6132 7001 2465 6113 6385 7708 9031 l0000 1569 3524 4394 5263 6132 7001 4'-0" PRECAST 1065 700 2305 3125 3945 4765 5587 4'-0 " PRECAST 514 763 4'-0" PRECAST 1363 3060 3815 4570 5325 6079 1961 6113 7192 6524 7627 8751 1363 1 3060 3815 4570 5325 6079 4'-6" PRECAST 819 533 1770 2400 3033 3666 4300 4'-6" PRECAST 398 591 4'-6" PRECAST 1207 1 2582 3375 4043 4711 5379 1625 5743 7547 6752 6541 7565 1207 2707 3375 4043 4711_ 5379 5'-4" PRECAST 931 1247 1999 2560 3123 3686 4249 5'-4" PRECAST 411 411 5'-4" PRECAST 1016 1806 2374 2944 3513 4084 1319 4460 7196 7342 5780 6259 1016 2276 2838 3399 3961 5'-10" PRECAST 817 1024 1631 2090 2549 3009 3470 5'-10" PRECAST 340 339 5'-10" PRECAST 909 1499 1971 2443 2915 _4084 3387 1161 3693 5877 6036 6548 5776 929 2080 2593 3107 3620 4133 6'-6" PRECAST 692 1139 3227 3031 3707 4383 5061 6'-6" PRECAST 410 721 6'-6" PRECAST 835 1201 1578 1955 2332 2709 1139 3227 4598 7054 10000 8825 835 1868 2329 2790 3251 3712 7'-6" PRECAST 570 938 2498 2205 2698 3191 3685 7'-6" PRECAST 303 534 7'-6" PRECAST 716 900 1181 1462 1743 2025 938 2498 3408 4864 7067 6472 727 1624 2025 2426 2827 3228 9'-4" PRECAST 428 633 1593 2204 2481 2818 2621 1 9 -4 PRECAST 192 384 ,- 9 4 PRECAST 454 586 767 948 1129 1310 639 1674 2298 3081 4099 4899 572 1318 1643 1969 2164 2519 10'-6" PRECAST 388 487 1247 1767 1904 2163 2028 10'-6" PRECAST 151 301 10'-6" PRECAST 356 468 612 755 899 1042 550 1407 1897 2781 3222 3784 504 1180 1472 1763 -- 1710 1989 11' 4" PRECAST 330 544 1312 1742 2252 2868 3630 11'-4" PRECAST 132 417 11'-4" PRECAST 430 406 530 653 777 872 544 1312 1742 2252 2868 3552 466 1042 - 1372 — 1643 1470 1710 12'-0" PRECAST 308 507 1210 1596 2048 2586 3191 12'-0" PRECAST 111 370 12'-0" PRECAST 383 366 476 587 698 783 507 1210 1596 2048 2586 3171 440 940 1300 1560 1314 1476 13'-4" PRECAST 270 433 1045 1365 1732 2157 2535 13'-4" PRECAST 82 298 13'-4" PRECAST 308 303 393 484 575 645 414 1045 1365 1732 2316 2605 396 780 1057 ------ 1312 - 1071 1203 14'-0" PRECAST 254 388 978 1272 1606 1988 2279 14'-0" PRECAST 71 293 14'-0" PRECAST 279 278 360 443 526 609 390 978 1272 1606 1950 2389 378 717 961 1192 975 1133 14'-$" PRESTRESSED N.R. NR NR NR NR NR NR 14'-8" PRESTRESSED N.R. 283 14'-8" PRESTRESSED 239 422 _ 506 626 746 865 ass 1079 1429 1824 2277 2712 246 663 980 1237 1474 — 1715 15'-4" PRESTRESSED N.R. NR NR NR NR NR NR 15'-4" PRESTRESSED N.R. 252 15'-4" PRESTRESSED 224 387 464 574 684 793 412 1014 1340 1703 2118 2513 230 616 908 ----- 1134 -- 1353 -- 1572 17'-4" PRESTRESSED N.R. NR NR NR NR NR NR 17'-4" PRESTRESSED N.R. 183 17'-4" PRESTRESSED 187 326 365 451 587 680 300 ass 1121 1413 1739 2047 192 506 720 501 1135 1312 19'-4° PRESTRESSED N.R. NR NR NR NR NR NR 19'-4" PRESTRESSED N.R. 148 19'-4" PRESTRESSED 162 266 348 430 513 595 235 736 959 1200 1467 1716 166 429 623 -- 803 950 1098 21'-4" PRESTRESSED N.R. NR NR NR NR NR NR 21'-4" PRESTRESSED N.R. 125 21'-4" PRESTRESSED 142 219 308 381 454 527 180 598 833 1038 1168 1468 142 373 537 690 816 943 22'-0" PRESTRESSED N.R. NR NR NR NR NR NR 22'-0" PRESTRESSED N.R. 116 22'-0" PRESTRESSED 137 226 290 359 428 497 165 550 784 992 1203 1381 137 358 513 659 779 900 24'-0" PRESTRESSED N.R. NR NR NR NR NR NR 24'-0" PRESTRESSED N.R. 91 24'-0" PRESTRESSED 124 174 245 _ 302 360 418 129 450 654 824 1014 1147 124 319 455 581 687 793 - ALL VALUES TAKEN AS THE LESSER FROM "SAFE LOAD TABLES" BY QUALITY 2018 EDITION, LOTT'S MAY 2015 EDITION - PRECAST PRODUCTS BY OTHERS TO MEET OR EXCEED VALUES STATED ABOVE AND CASTCRETE MAY 2015 EDITION. - ALL PRECAST PRODUCTS ARE TO BE INSTALLED PER MANUFACTURES SPECIFICATIONS - PROVIDE MINIMUM 4" OF BEARING PAST EACH SIDE OF WINDOW OPENING PRODUCT CONTROL NOTICE OF ACCEPTANCE F.E.C.P. CORPORATION -CAST E-CRETE DIVISION ACCEPTANCE #: 19-0130.13 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 3 0 U W o I 4 U W Q F a SUBDIV. & LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT# 04321.200 083R1 MODEL: 4EHB "2605-HAYDEN' GARAGE SWING: LEFT PAGE: SAFE LOAD TABLES 60 MPH EXP. C ARCHITECT - STATE OF FLORIDA MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 rrcaan a DATE: 03 19 21 SCALE: 1/4"=1'-0" 1 SHEET Ste 2A FRAMING NOTES: 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9) 10d x 1 1/2" HDG NAILS. CONCRETE TO WOOD FLOOR: SIMPSON LTA2 W/ (8) 10d x 1 1/2" HDG NAILS, WOOD TO WOOD: SIMPSON H10A OR LGT2 W/ 10d x 1 1/2" HDG NAILS, FILL ALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, CONNECTERS ARE TO BE GALVANIZED. 6. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE CONCRETE LINTELS. 7. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS. 8. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). 9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL. 10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2X MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED FASTENER, ZF72 PBS36, .177" °x 2 7/8" LONG, WITH WASHER@ 16"O.C. 11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 12; WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. 13. ALL ELEVATIONS ARE REFERENCED FROM U-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. I TRUSS MANUFACTURER / ENGINEER NOTES: 1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2,500 LBS SHALL BE FABRICATED W/ A 2x6 BTM. CHORD (MIN.) 2. COORDINATE ANY TRAY/COFFERED CEILINGS, AND ATTIC ACCESS WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION AND MISTAKES. 3. TRUSS COMPANY / ENGINEER IS RESPONSIBLE FOR ALL TRUSS TO TRUSS CONNECTIONS. 4. AVOID PLACING A TRUSS PERPENDICULAR TO STEEL COLUMN.' MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN. COLUMN SCHEDULE MARK SIZE & BASE PLATE OR REMARK DESCRIPTION REINFORCEMENT WD-1 4X6 (3 Y"x5 Y") SYP. HTT4 W/5/8" D IA x 5" 5/S3.1A PT., WOOD POST EXP. BOLT r - - - - - - - -1. FIRE DRAFT STOP 3/4" SUB FLOOR �ti 2X4 NAILER FOR DRAFT PRE-ENG. STOP FLR. TRUSS 1 ELEV. VIEW �II PRE-ENG. FLR. JOISTS 'I �I 3/4" PLYWOOD_�''I DRAFT STOP �I PRE-ENG. FLR. JOISTS 2X4 NAILER FOR DRAFT STOP 3/4" PLYWOOD DRAFT STOP PLAN VIEW DRAFT STOP DETAILS T o, CJ1L n nEJ3 II CAL 9 1 A L2G 3.1 GT tiq �Q 9B 9A 9A 10B 3-- W -- 3.1 3.1 3.1 IT I� II II II II II II II II II II I II II II II II II II I III � n n n n u u u u u u n a n u u III II II II II II II II II II II II I I II II II II II II II .III , Ir II II II IIII IlII II fl 0 II II 11 II II III II II� 11 11 11 19 II II Ih J2 J3 I I I I I I I I I I I I I I I I 11 II 11 I I I I I I III II LI II II II II II 21x4 WOOD WALL W- II II II II II II II II II Ill 3.1 II II it SYP. NO.2STUDS 2x4 WOOD II II II II II II @ 12 O.0 I II SYP II II II WALL W/ NO 2 JI II II II II I III 111 I I II 11 11 11 L. II II II II 11 11 STUDS D1 II II n@ 11 II II II II II W 12' O.C. w II II 2X6 WOOD II �=j BM1 WALL W/ DBL. J6 III II II STUD UNDER 6 FF w EACH JOIST 4 I�=== J4_ II -n n n II 11 3.1 --- -_ III - III tt 4 DBL STUD ' 11 III 1 3.1 'll\r( IIu112X4 WOOD 9A PROVIDE DRAFTSTOII WALL W/ DEL. III 11 ALONG THIS TRUSS AS TO 11 STUD UNDER ° II 4 III II LIMIT AREATO 1000 S.F. II EACH JOIST III PER FBCR 302.12 J7 -II_ = =_ 111 IIIII u u u n n n II n n PRE -FABRICATED FLOOR7II 'Il II II II �� II II II II II I I I I+� _ =...JOISTS @ 24" O.C. - �d III I I I I 11 I I I I I I 11 --..I I I I I I III n - III If n n n n n n n n n " II II II II II II II II II II � GT In nI II -tiQn C_J5 = e 33. _CJ3ELLL L -1_A toI IIII n gB EJ6E III II CJ 1 E 3.1 II If II 1t II 10B EGE 3.1 W cLu w 3 FIRST FLOOR FRAMING PLAN SCALE: 1/4" = V-0" 1-JOIST BM1 TO CMU WALL W/ SIMPSON LGUM46-SDS W/ (4) %" x 4" TITEN HD ANCHORS AND (4) X" x 2 Yz" SDS SCREWS TO BM1 3 101 rmrmg Reviewed for Code Compliance ud Universal Engineering Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdosigngroup.com AA #: 0003325 11-11�1 fi PACE: FIRST FLOOR FRAMING PLAN 00 MPH EXP. C MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17300 PRINT DATE: 03 19 21 SCALE: 1/4"=V-0" SHEET S 3 L A-(1) SIMPSON HETA16 TRUSS ANCHOR WITH (9) 1 Od x 1 2" NAILS TO TRUSS B-(2) SIMPSON HETA16 TRUSS ANCHOR WITH (12) 16d x 1 z" NAILS TO TRUSS DBL STRAP, 1 EACH SIDE WRAPS UP AND OVER TRUSS (NOT SHOWN) C-(1) SIMPSON LGT2 GIRDER TIEDOWN WITH (16) 1 Od x 3 4" NAILS TO GIRDER AND (2) SIMPSON HETA16 TRUSS ANCHORS WITH (12) 16d x 3 Z" NAILS TO GIRDER Ix2, 2x WOOD FASCIA SEE ARCHITECTURAL 2x SECURED GALV. COMMON NAILS. 1x2 SECURED W/ 10d GALV. COMMON NAILS 12" O/C k I, MASONRY BOND BEAM PLYWOOD SHEATHING, SEE "ROOF/WALUFLOOR SHEATHING FASTENER SCHEDULE" NOTE: APT SYP #22"x4", 6", 8" x 4'-0" MAY BE ADDED W/ 1 Od NAILS, 2 ROWS, 3" O/C TO FACILITATE ONE ADDITIONAL PLY MAX. TO ACCOMMODATE TRUSS ANCHOR REQUIREMENTS. ENGINEERED WOOD TRUSSES @ 24" O/C, SUBMIT SHOP DRAWINGS FOR REVIEW AND APPROVAL SEE SCHEDULE A ALLOWABLE UPLIFT = U:1810 LBS, L,:770 LBS (1 PLY) B ALLOWABLE UPLIFT = U:2365 LBS, 1_ 1430 LBS (2 OR 3 PLY) C ALLOWABLE UPLIFT = U:2705 LBS (2 PLY) TYPICAL TRUSS/ F 1 a 1 b 1 c SCALI I GIRDER CONNECTOR(S) SERIES BACKER BLOCK THICKNESS 4500 3/4" WOOD PANELS 6000 (2)1/2"WOOD PANELS 50 (2) 1/2" WOOD PANELS 90 2x LUMBER 3/4" T & G SUBFLOOR GLUED AND SCREWED AS PER SCHEDULE a , PRE-ENG I -JOIST' 5/8" GYPSUM BOARD OR 1/2" HIGH STRENGTH CLG. BOARD; SECURE I -JOIST TO TOP PLATE w/ (2) 12d TOENAILS DOUBLE TOP PLATE 2x4 OR2x6 WOOD BEARING WALL W/ SYP No 2 STUDS SEE PLANS FOR SPACING. SINGLE BTM. PLATE TO BE PT. PROVIDE DBL. TOP PLATE PROVIDE BLOCKING 112" GYP. WL. BD. SEE SHEET S1.1A FOR NAIL SIZE AND PATTERN i I -JOIST CONNECTION @a L.B.W. SCALE: 3/4"=V-0" (NO UPLIFT) NOTCH DEPTH 1/4`D �0 HOLE EDGE >5/8" HOLE DIAMETER I", — < 2/5"D SGL. STUD OUTER 1/30F SPAN ONLY HO BTM. - PLATE AND BORING LIMITS $ SCALE 1 1/2"=V-0" EDGE >5/8" HOLE DIAMETER < 3/5*D DBL. STUD ENGINEERED WOOD TRUSSE PLYWOOD SHEATHING, SEE @ 24" O/C, SUBMIT SHOP "ROOF/WALUFLOOR DRAWINGS FOR REVIEW SHEATHING AND APPROVAL FASTENER SCHEDULE" (1) SIMPSON HETA16 TRUSS ANCHOR WITH NOTE: A PT SYP #2 2" x 4", (9) 1 Od x 1 2' NAILS TO 6", 8" x 4'-0" MAY BE ADDED GIRDER. PROVIDE 5" W/ I Od NAILS, 2 ROWS, 3" MINIMUM CONCRETE O/C TO FACILITATE ONE EMBEDMENT. USED IN ADDITIONAL PLY MAX. TO CONJUNCTION WITH ACCOMMODATE GIRDER HEAVY UPLIFT TIEDOWN REQUIREMENTS. CONNECTOR A-(1) SIMPSON LGT3-SDS2.5 GIRDER TIEDOWN WITH (4) e" x 5"TITEN HD TO CMU AND (12) SDS �' x 2 2" TO GIRDER B-(1) SIMPSON FGTR GIRDER TIEDOWN WITH (2) 2x 5" TITEN HD TO CMU AND (18) SDS a x 1x2, 2x WOOD FASCIA TO GIRDER SEE ARCHITECTURAL' C-(2) SIMPSON FGTR GIRDER TIEDOWNS WITH 2x SECURED W/ (3) 16d (2) z"x 57ITEN HD TO CMU AND (18) SDS 4" x 3" GALV. COMMON NAILS. 1x2 SECURED W/ 10d MASONRY BOND SCREWS TO GIRDER (EACH TIEDOWN) GALV. COMMON NAILS BEAM ENSURE THAT CELLS ARE GROUTED 12" O/C SEE SCHEDULE SOLID, 8" EACH WAY OF BOLTS A ALLOWABLE UPLIFT = 3285 LBS (2 OR 3 PLY) B ALLOWABLE UPLIFT = 4725 LBS (2 PLY MIN.) C ALLOWABLE UPLIFT = 8885 LBS (2 PLY MIN.) TYPICAL ROOF 2a 2b 2C SCALE:3/4"=V-0" GIRDER CONNECTOR(S) LSTA12 20 GAUGE W/ 10dx1/2 HDG COMMON NAILS. @ EACH END TOTAL OF 10 SERIES BACKERBLOCK THICKNESS 4500 3/4" WOOD PANELS 6000 (2) 112" WOOD PANELS 60 (2) 1/2" WOOD PANELS 90 2x LUMBER LVL/I-JOIST WITH BACKER BLOCK HTT4 W/ 5/8" A.B. WITH MIN. 7" EMBEDMENT TO SLAB & (18) 16d x 2-1/2" NAILS TO POST., POST TO SIT DIRECTLY ON SLAB —` LVL/WOOD POST CONNECTIONS '3UALL. 324"-V-U A - SIMPSON IUS1.81/16 G < 1400 LBS, U < 70 LBS W/ (2) 3/4"° WEDGE-BOLT/J-BOLT, 5" MIN. EMBED (14) 10d GALV. COMMON NAILS TO HEADER FL#17241 B - SIMPSON IUS2.37/16 G < 1400 LBS, U < 70 LBS W/ (2) 3/4"° WEDGE-BOLT/J-BOLT, 5" MIN. EMBED (14) 10d GALV. COMMON NAILS TO HEADER FL#17241 C - SIMPSON MIU3.56/16 G < 2900 LBS, U < 210 LBS W/ (4) 3/4"° WEDGE-BOLT/J-BOLT, 5" MIN. EMBED (24) 16d GALV. COMMON NAILS TO HEADER AND (2) 10dxl-1/2" GALV. NAILS TO JOIST FL#17241 D - SIMPSON HHUS725/10 G < 4140 LBS, U < 1610 LBS W/ (8) 3/4"° WEDGE-BOLT/J-BOLT, 5" MIN. EMBED (16) 16d GALV. COMMON NAILS TO HEADER AND (10) 16d GALV. NAILS TO JOIST FL#25749 E SIMPSON MIU4.75/16 G < 3455 LBS, U <210 LBS W/ (8) 3/4"° WEDGE-BOLT/J-BOLT,5" MIN. EMBED 16d GALV. COMMON NAILS TO HEADER AND (2) 10dx1-112" GALV. NAILS TO JOIST FL#17241 WOOD LEDGER 9 ATTACHMENT.DETAIL SCALE: 3/4"=V-0 6-0" MAX (W/1 X4) OR 10'-0" MAX (W/2X4) F # 1100 UPLIFT SIMPSON HTSM20 W'10 1 Od TO TRUSS AND (4) 1/4" x 2 1/4" TITEN 2 ANCHORS TO CONT POURED LINTEL # 1900 UPLIFT (2) SIMPSON HTSM20 INSTALLED ON OPPOSITE FACES OF BLOCK WALL W/1010dTO TRUSS AND (4) 1/4" x 2 1/4" TITEN 2 ANCHORS TO CONT POURED LINTEL PRE-ENG TRUSS CONTINUOUS' BOND BEAM TITEN 2 ANCHORS MIN 2" COVER & 2" APART REPAIR OF MULTIPLE MISPLACED EMBEDDED TRUSS ANCHOR 3 SCALE 3/4"=V-0" (2) 2X4 No.2 SYP DIAG.' 2x4 BLOCKING BETWEEN BRACE W/ (3) 12d @ EA. TRUSSES WHERE TRUSS (DIAL. BRACE TO X-BRACING IS PRESENT AT COVER 5 TRUSSES) 4'-0" O.C. (AT SHEATHING 0' 0" TO 30'-0" 11 I "X" BRACE SEAMS) 30'-1" TO 60'-0 (3) "X" BRACE SECURE 2x PT. PLATE (1) "X" BRACF @ CENTER TO BLK W/ 1/2" DIA. 12) "X" BRACE DIVIDED EQUALLY ANCHOR BOLT W/ 2" FROM CFNTFR TO FND. WASHER SET IN HIGH 2x WOOD FASCIA, STRENGTH EPDXY 6" SEE ARCHITECTURAL MIN. EMBED. AT 32" OC 1x4 DIAGONAL MAX. BTM. CHORD PRE-ENGGABLE TRUSS - SECURE GABLE TO 2x8 BRACING, SEE P.T. PLATE W/ 12d's 8" PLAN FOR LOCATION STIFFBACK (AS PER -- O.C. MAX MAY NOT BE REQUIRED I RUSS ENG) CONT. 2x4 SECURED W/ (2) 1 Od's @ EACH TRUSS TO BE INSTALLED @ BTM. CHORD OF I 10'-0" O.C. MAX: WOOD ROOF TRUSSES 1x4 BTM. CHORD BRACING 6-0" O/C END WALL OR OTHER MAX., OR 2x4 BTM. CHORD BRACING END TYPE CONDITION, IF 10'-0" O/C MAXSECURED W/ (2) 10d CHORD / + DEPICTED SEE PLAN COMMONSECTIOLSATEACHCHOR BTM. CHORD BRAVING INTERSECTION TYP: SCALE: 3'4"=1'-O" ' 24" 24" MAX. wl Io151 MAX. SPACING ENDB" END w/1-JOIST TRUSS ERG. BTM. PACIN SSEE FRAMING PLAN TYP. vP. vR. END OF MAX MAX MAX LEDGER BD. 1EXP. X8 SYP P.T. LuLEDGER EDGE BOLT/J-BOLTLT W/ 2" BOARD LEDGER BOARD TO BOLT,J BOLT Wi 2" WASHER & 51/2" TO BE USED 1. ENSURE TI ]AT EXP. BE USED WITH I-JOISI WASHER & 5 1/2" MIN. EMBED.(TYP) WITH I -JOIST BOLI S J-BOLI S ARE PLACED MIN. EMBED.(TYP) INTO GHOU I ED CELLS. 8" ALL AROUND BOLT. FRONF - 2. SPLICE OF FRONT AND REAR LEDGER - LEDGER SI IOULD LAP A MIN 01 - Z 4._ Z. �o 3. ALL BOLTS TO I IAVC WASIILRS 1 14 4. EXP. BOLIS/.I-BOLISSHOULD 1212X12 NOT BE ANY CLOSER I HAN 6" SYP PT z Z_ O/C. 00 5. ONLY LEDGER IN DIRECT °J � (2) 2X8 CONTACT (REAR LEDGER) WITI I REAR r SYP PT CMU REQUIRED 10 BE P.l. LEDCER FLOOR JOIST LEDGER SCHEDULE MARK A SIZE DOUBLE SYP 2x8 BOLT SIZE 1,12" (2) 3/4" END SPACING 8" MAX. 8" MAX. CENTRAL SPACING 24" O/C MAX. 24" O/C MAX. B DOUBLE SYP 2x12 I -JOIST WOOD LEDGER DETAIL 61JALE: 3/4"=V-0' SEE SCHEDULE FOR ---- BOND BEAM REG. BLOCK WALL W/ GABLE END PRE-ENG'D TRUSS SCALI 1,-0„ Reviewed for Code 93 Compliance Universal Engineering Sciences THE USE OF ALTERNATE MATERIALS MAY BE USED SO LONG AS THEY CONFORM TO THE FOLLOWING 1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS A) AN ALTERNATE STRAP MAY USED SO LONG AS THE NEW STRAP HAS EQUIVALENT OR GREATER UPLIFT AND LATERAL (F1 AND F2) LOAD CAPACITIES AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO A SIMPSON H10A OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, F1, AND F2 FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE SUBJECT TO F1 AND F2 FORCES. ALTERNATE MATERIALS SCALE: 3/4"=V=®',, 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 100 fF . a CREEKSIDE PHASE 2 I-J LOT #83 g PIROJECT# 04321.200 083R1 MODEL: 4EHB "2605—HAYDEN" GE SWING: LEFT PAGE: 1� DETAILS (I— JO IS T) 160 MPH EXP. C 00 ARCHrrECT. f8'117ATE OF FLORIDA MAR 2 2 2021 ICHAEL C. ANDERSON AR NO 17305 UNWOMMM OMMM IIoTT jA E / ' 21 SCALE: 1/4"=1'- SHEET S3. 1 i ■ SIMPSON H6 W; (8)8d COMMON NAILS 2x STUDS SIMPSON H6 W/(8) Sd EACH END - - REFER TO NAILINGSCHEDULE ON SHEET COMMON NAILS. EACH SN1 FOR SUBFLOOR END EVERY STUD OR ON REFER TO NAILING ATTACHMENT TO EACH END OF "BUNDLE" SCHEDULE ON SHEET OF STUDS SN1 FOR SUBFLOOR LEDGER BOARDS ATTACHMENT TO DBL. 2X8 SYP #2 LEDGER. PLYWOOD FLOOR LEDGER BOARDS SEE BOLT SCHEDULE, SHEATHING 10/S3.1A. 8" CMU WALL REINF PER PLAN 8" CMU WALL REINF PER PLAN Ir_ PER ELEVATION _ PER ELEVATION O �� LL w0= � N I JOIST ISEE O gZ O OInQ _ FRAMING PLAN) �OU Z W N.: O�< N G Zy Lu PER ELEVATION m� O_ PER ELEVATION m'-- (2) 2x4 P.T. W,' "-- kq2 MASONRY NAILS DBL2X12SYP#2LEDGER.SEE _ I -JOIST (SEE BOLT SCHEDULE, 10'S3.1A. 2x4 P-T- CEILINGFRAMING PLAN) @ 12" O.C. NAILER W! MASONRY NAILS SIMPSON SPH41SPH6 BTM. 1X2 FIRE -STOP q 12" O.C. 1 JOIST LVL PLATE STRAPS W/ 10d x 1 1/2"HDGNAILS SECTION DETAIL 1X2FIRF-SIOR- SECTION DETAIL WALL / FLOOR FRAMING, AT I -JOISTS PERPENDICULAR AT I -JOISTS PARALLEL I -JOIST PARALLEL TO WALL TO EXTERIOR WALL TO EXTERIOR WALL 2 SCALE: 3/4'1 3 ��LE: 3/4"1 PRE-ENG GABLE TRUSS 2x4 BLOCKING BETWEEN TRUSSES AT FIRST TWO BAYS 4'-0" O.C. (AT STRAP TRUSS TO PL —91 N4 PRE-ENG SHEATHING SEAMS) (BLOCKING o PRE-ENG'D WOOD SEE SCHED. BELOW ROOF TRUSS NOT SHOWN FOR CLARITY) TRUSS (TYP) @ 24" O.C. MAX 0 2X4 DIAGONAL BTM. CHORD PER ELEVATION BRACING. SEE PLAN FOR _ LOCATION FOR STRAPPING R VERIFY \ PRE-ENG ROOFTRUSS SECURE 2x6 PT. PLATE TO BLK W, TRUSS PLAN TRUSS TO TOP PLATE 5%8" GYPSUM BOARD OR 112" HIGH W/ 1/2" DIA. ANCHOR BOLT W/ 2" A - SIMPSON MTS12 STRENGTH CLG. BOARD WASHER SET IN HIGH 4x4'4x6 SYP NO.2 U < 990 LBS W/ (14) 10d SECURE TRUSS TO TOP PLATE w/ (2) WOOD POST TO Reviewed for STRENGTH EPDXY 6" MIN. GALV. NAILS. 16d TOENAILS B - (2) SIMPSON MTS12 DOUBLE TOP PLATE Universal n In g EMBED. AT 32" OC MAX. SLAB. SEE Complianee SECURE GABLE TO 2x8 P.T. U < 1420 LBS W/ (14) 10d SCHEDULE Scisnce;eenn BELOW FOR 29 PLATE W/ 12d's 8" O.C. MAX GALV. NAILS EA. STRAP 2x4 OR 2x6 WOOD BEARING CONNECTION WALL W1 SYP No 2 STUDS SEE FL#17239 CONC. POURED PLANS FOR SPACING. SINGLE BTN1 PLATE TO BE PT. LINTEL COURSE PROVIDE DBL. TOP PLATE n PROVIDE BLOCKING - SIMPSON SPH4 OR SPH6 BTM °_,v 1i2" GYP. WL. BD. AND TOP PLATE ANCHORS W, 10d x 1 1,2" COMMON NAILS SECURE BT. PLATE TO SLAB W' Li FILL ALL HOLES, DO NOT USE 12"x9" WEDGE ANCHOR W/2" TRUSS TO CNSTALL Ca) -0" EACH WASHER SET IN HIGH STRENGTH TRUSS/WOOD POST CONNECTIONS TRUSS TO BE INSTALLED @ 10'-0" O.C. MAX. 10d x 3" 10a 10b 10c EPDXY 5-1!2" EMBED. MIN. @ 16" OC MAX. GABLE END BRACING W/ PRE-ENG $ GABLE TRUSS @ CMU WALL SCALE: 314"=V-0" TRUSS TO POST CONNECTION A - SIMPSON MTS-12 U < 990 LBS W1(14) 10d GALV. NAILS. B - SIMPSON HTS-20 U < 1310 LBS W,/ (20) 10d GALV. NAILS. C - 2-PLY-SIMPSON VGT/HDU4 U < 4565 LBS VGT TO TRUSS W/ (16) 1/4"x3"SDS, (1) 5/8"' A.T.R. TOHDU4 AND (10)1/4"X21/2"SDSTOPOST ga gb TRUSS CONNECTION @ L.B.W. POST TO SLAB CONNECTION SCALE 3!4"-1'-0' A&B - SIMPSON ABU44Z POST BASE <tJ:1,900 G:5.660 W 5'8 DIA. x 6" EXP. BOLT SIMPSON ABU46Z POST BASE <U:2,300 0:10,335 W/ 5/8 DIA. x 6" EXP. BOLT C - SIMPSON HTT5 POST ON SLAB <U:4,565 WI5/8" A.B. WITH MIN. 7" EMBEDMENT TO SLAB & (26) 16d x 2-112" NAILS TO POST. 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W W a U w 0 F 0. v W O F A F ti SVSDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT* 04321.200 083R1 MODEL 4EHB "2605-HAYDEN" GARAGE S VfMG: LEFT PACE: DETAILS (I -JOIST) 60 MPH EXP. C ARCHrrECT: STATE OF FLORIDA MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 rr &N s DATE: 03 19 21 SCALE: 1 /4"=1' - 0" SI3EE^'' S 3 > 1I� JLR SIDE VIEW 1 VTCR SPACING (1) AT EACH END ai.in a'_n^ n C. MAX. PRE-ENGINEERED VALLEY TRUSS CONNECTION SCALE: N.T.S. Reviewed for Code Compliance Universal Engineering Sciences 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #i 0003325 UIBDIV: & LOT- & CREEKSIDE PHASE 2 LOT #83 PROJECT* 04321.200/083R1� MODEL• 4EHB fI "2605-HAYDEN" ,1^,ARAGE SWING: 0 LEFT DETAILS 60 MPH EXP. ARC,WrECT. STATE `°)F FLOW )A MAR 2 2 7021 I 39'-8" 2'-8" 14'-0" 17'-4" 2'-0" T-0" I I L------------------------1 39'-8" SECOND FLOOR DECK PLAN SCALE: 1l4" = 1'-0" LL r V OP 0 CP O d Reviewed for Code Compliance Universal Engineering - Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 F W 0 U W W F 0. I; ca W 4 ti Lo SUBDIV. 8e LOT CREEKSIDE PHASE 2 LOT #83 PROJECT* 04321.200 083R1 f MODEL: 4EHB "2605-HAYDEN' GARAGE S VfMG: LEFT PAGE: SECOND FLOOR DECK PLAN �L60 MPH EXP. ARCHFECT= STATE OF FLORIDA -� tom_ MAR 2 2 2021 MICHAEI ' C. ANDER' ON AR 140 17305 PRINT 03 19 21 DATE- / / SCALE: 1/4" =1' — 0" SHEET S4 -1 co bo oa N N 0 - in 0 SECOND FLOOR DOWEL PLAN SCALE: 1/4" = V-0" NORPON Reviewed for Code Compliance Universal Engineering Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 fi a i UBDIV. & LOT: CREEKSIDE PHASE 2 LOT #83 -PROJECT* 04321.200 083R1 MODEL: 4EHB "2605- HAYDEN" GARAGE SWING: LEFT PAGE: SECOI D FLOQR DOWEL PLA q 60 MPH EXP. C ARCHfTECT. STATE OF FLORIDA MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 "PRINT DATE: 03 19 21 SCALE: 1/4"=1' — 0" SHEET S -A--F-2 FRAMING NOTES: ;I 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE XAII k n InA x I I/01'LJr)r_'K1A1 CONCRETE E_ 1 0 WOOD ROOF: SIMPSON mr- 1 A lb CONCRETE TO WOOD FLOOR: SIMPSON LTA2 W1 (8) 1 Od x 1 1/2" H DG NAILS, WOOD TO WOOD: SIMPSON H1 OA OR LGT2 W1 1 Od x 1 1/2" HDG NAILS, FILL ALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSSTO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, CONNECTERS ARE TO BE GALVANIZED. 6. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE CONCRETE LINTELS. 7. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS. 8. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). 9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL. 10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED FASTENER, ZF 72 NS36,.1177 0 x 2 7/8" LONG, WITH WASHER @ 16" O.C. 11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 12. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. 13. ALL ELEVATIONS ARE REFERENCED FROM Y-O", FINISH FLOOR. UNLESS NOTED OTHERWISE. I HEADER SCHEDULE MARK SIZE & REMARK DESCRIPTION (D (2) 2X8 BEAM SCHEDULE ZM?�M INDICATES OPENING BELOW/ T.O.B. =TOP OF BEAM/ B.O.L. =BOTTOM OF LINTEL/ T.O.A. =TOP OF ARCH /T.O.$ =TOP OF SLAB ABBREVIATIONS E.E. = EACH END, O/C = ON CENTER, F.E.S. = FROM EACH SUPPORT, T.O. = THROUGHOUT MARK DESCRIPTION C (psi) P S 1) E F! ZX H' REINFORCEMENT STIRRUPS REMARKS BTM. TOP MID SIZE SPACING BB1 MASONRY 3000 8x16 (1) #5 (1) #5 N/A GROUTED SOLID BB2 MASONRY 3000 8X8 (1) #5 — _ N/A GROUTED SOLID SEE SHEET S5.1 A FOR SAFE LOAD TABLES . . . . . . . . . . . . . . . . I 8F16-1T/0M/0B F16-1T/0M/0B 8F16-1T/0M/0B CD ♦ GT U.N.O. PROVIDE BB2 WHERE ROOF TRUSSES BEAR, TOP OF WALL EL 18'-8" F, ## ## *+. % % % ♦% % % GT % 3q % % % % % % % % % % % 8F16-IT;0Mi0B --------I % r L. . . . . . . ###8F16_1T/0M/0B 8F16-1T/0M/0B 8F16-1T'0M,'0B % % 2.1 I - a, %% V. . . . . . . . . . . . . . . . . . . . . . . . . . . . SECOND FLOOR LIFT BEAM PLAN SCALE: 1/4" = V-0" Reviewed for Cod m a a Compliance Universal Engineering Sciences 2194 HWY AJ.A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-359:1 www.abdesigngroup.com AA #: 0003325 SUBDIV. CREEKSIDE PIASE E 2 'I LET #83'? PROJECT# 04321.200/083R1 MODEL. 4EHB J "2605-HAYDEN" GARAGE SWING: ha LEFT PAGE: :SECOND FLOOR J LIFT BEAM PLAN 60 MPH EXP. 0, ARCHITECT STATE OF FLORIDA MAR 2 2 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT DATE: 03/19/21 SCAMP: 1/4"=1'-O SHEET S5 "LOTT'S CONCRETE" / "CAST-CRETE" / "QUALITY" SAFE LOAD TABLE_ S _ SAFE GRAVITY LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS FF SAFE LATERAL LOADS FOR SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS SAFE LOAD - POUNDS PER LINEAR FOOT TYPE LENGTH 8U8 8/8-OB /16-1T/OB /20-1T/OB /24-1T/0B /28-1T/0B /32-1T/0B 8/8-1B /16-1T/1B 120-1T/16 /24-1T/1B /28-1T/1B /32-1T/1B 3'-6" PRECAST 1436 952 3114 4217 5321 6426 7531 2465 6113 6385 7708 9031 10000 4'-0" PRECAST 7065 700 2305 3125 3945 4765 5587 1961 6113 7192 6524 7627 8751 4'-6" PRECAST 819 533 1770 2400 3033 3666 4300 1625 5743 7547 6752 6541 7565 5'-4" PRECAST 931 1247 1999 2560 3123 3686 4249 1319 4460 7196 1 7342 5780 6259 5'-10" PRECAST 817 1024 1631 2090 2549 3009 3470 1161 3693 5877 6036 6548 1 5776 6'-6" PRECAST 692 1139 3227 3031 3707 4383 5061 1139 3227 4598 7054 10000 8825 7'-6" PRECAST 570 938 2498 2205 2698 3191 3685 938 2498 3408 4864 7067 6472 91-4" PRECAST 428 633 1593 2204 2481 2818 2621 639 1674 2298 3081 4099 4899 10'-6" PRECAST 388 487 1247 1767 1904 2163 2028 550 1407 1897 2781 3222 3784 11' 4" PRECAST 330 544 1312 1742 2252 2868 3630 544 1312 1742 2252 2868 3552 12'-0" PRECAST 308 507 1210 1596 2048 2586 3191 507 1210 1596 2048 2586 3171 13' 4" PRECAST 270 433 1045 1365 1732 2157 2535 414 1045 1365 1732 2316 2605 14'-0" PRECAST 254 388 978 1272 1606 1988 2279 390 978 1272 1606 1950 2389 14'-8" PRESTRESSED N.R. NR NR NR NR NR NR 458 1079 1429 1824 2277 2712 15'-4" PRESTRESSED N.R. NR NR NR NR NR NR 412 1014 1340 1703 2118 2513 17'-4" PRESTRESSED N.R. NR NR NR NR NR NR 300 856 1121 1413 1739 2047 19'-4" PRESTRESSED N.R. NR NR NR NR NR NR 235 736 959 1200 1467 1716 211-4" PRESTRESSED N.R. NR NR NR NR NR NR 180 598 833 1038 1168 1468 22'-0" PRESTRESSED N.R. NR NR NR NR NR NR 165 550 784 992 1203 1381 24'-0" PRESTRESSED N.R. NR NR NR NR NR NR 129 450 654 824 1014 1147 SAFE LOAD PLF TYPE LENGTH 8/8 PLAIN 8/8 SOLID T-6" PRECAST 689 1024 4'-0" PRECAST 514 763 4'-6" PRECAST 398 591 5'-4" PRECAST 411 411 5'-10" PRECAST 340 339 6'-6" PRECAST 410 721 7'-6" PRECAST 303 534 9'-4" PRECAST 192 384 10'-6" PRECAST 151 301 11141 PRECAST 132 417 12'-0" PRECAST 111 370 13'-4" PRECAST 82 298 14'-0" PRECAST 71 293 14'-8" PRESTRESSED N.R. 283 15'-4" PRESTRESSED N.R. 252 17'-4" PRESTRESSED N.R. 183 19'-4" PRESTRESSED N.R. 148 2114" PRESTRESSED N.R. 125 22'-0" PRESTRESSED N.R. 116 24'-0" PRESTRESSED N.R. 91 - ALL VALUES TAKEN AS THE LESSER FROM "SAFE LOAD TABLES" BY QUALITY 2018 EDITION, LOTT'S MAY 2015 EDITION AND CASTCRETE MAY 2015 EDITION. - ALL PRECAST PRODUCTS ARE TO BE INSTALLED PER MANUFACTURES SPECIFICATIONS PRODUCT CONTROL NOTICE OF ACCEPTANCE F.E.C.P. CORPORATION-CASTE-CRETE DIVISION ACCEPTANCE #: 19-0130.13 SAFE LOAD - POUNDS PER LINEAR FOOT 8/8-1T 8/16-1T 8/20-1T 8/24-1T 8/28-1T 8/32-1T 8/8-2T 8/16-2T 8/20-2T 8/24-2T 8/28-2T 8/32-2T TYPE LENGTH 3'-6" PRECAST 1569 3524 4394 5263 5263 4570 6132 7001 1569 3524 4394 6132 7001 4'-0" PRECAST 1363 3060 3815 5325 6079 1363 3060 3815 4570 5325 6079 4'-6" PRECAST 1207 2582 3375_ 4711 5379 1207 2707 3375 _4043 4043 _ 4711 3513 5379 4084 5'-4" PRECAST 1016 1806 2374 2944 1016 2276 2838 3399 2443 3107 3961 2915 4084 5-10" PRECAST _ 909 1499 1971 929 2080 2593 36_20 -3387 4133 U-6" PRECAST 835 1201 1578 1955 2332 2709 835 1868 2329 2790 3251 3712 7'-6" PRECAST 716 900 1181 1462 2426 1743 2025 727 1624 2025 2827 3228 9'-4" PRECAST _ 454 586 767 948 1969 1129 2164 1310 572 1318 1643 2519 PRECAST _ 356 468 612 899 1042 504 1180 1472 _755 1763 1710 1989 1l'-4" PRECAST 430 406 530 653 _ 1643 587 777 872 466 383 1042 366 1372 476 - 1470 698 1710 783 12'-0" PRECAST 440 940 1300 1560 1314 1476 645 13' 4" PRECAST 308 303 393 484 575 396 1 780 1057 1312 1071 1203 14'-0" PRECAST 279 278 360 443 526 609 378 717 961 1192 975 1133 14'-8" PRESTRESSED 239 422 506 626 746 865 246 663 980 1237 1474 1715 15'-4" PRESTRESSED _ 224 387 464 574 684 793 230 616 908 1134 1353 1572 17'A" PRESTRESSED 187 326 365 587 680 192 506 _ 720 _451 501 1135 1312 19'-4" PRESTRESSED 162 266 348 430 513 595 166 429 623 803 950 1098 21'-4" PRESTRESSED 142 219 308 381 454 527 142 373 537 690 816 943 22'-0" PRESTRESSED _ 137 226 290 359 428 497 137 358 513 659 779 900 24'41 PRESTRESSED 124 174 245 302 360 418 124 319 455 581 687 793 - PRECAST PRODUCTS BY OTHERS TO MEET OR EXCEED VALUES STATED A - PROVIDE MINIMUM 4" OF BEARING PAST EACH SIDE OF WINDOW OPENING Reviewed for Code ED Compliance Universal Engineering Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 00133325 U w 0 0. U 03 w 0 F a sUHDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #83 PROJECT* 04321.200 083R1 MODEL: 4EHB "2605-HAYDEN" GARAGE SWING: LEFT PAGE: SAFE LOAD TABLES 60 MPH EXP. C ARCHITECT - MAR 2 2 V21 MICHAEL C. ANDERSON AR NO 17305 PRINT DATE: 03 19 21 SCALE: 1 /4"= V — 0" SHEET 5 . 1 A G TRUSS MANUFACTURER / ENGINEER NOTES: 1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2,500 LBS SHALL BE c FABRICATED W/A 2x6 BTM. CHORD (MIN.) c 2. COORDINATE ANY TRAY/COFFERED CEILINGS, AND ATTIC ACCESS FRAMING NOTES; WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION AND MISTAKES - CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9) 10d x 1 1/2" HDG NAILS. 3. TRUSS COMPANY /ENGINEER IS RESPONSIBLE, FOR ALL TRUSS TO TRUSS CONNECTIONS. CONCRETE TO WOOD FLOOR: 4. AVOID PLACING A TRUSS PERPENDICULAR TO A STEEL COLUMN. SIMPSON LTA2 W/ (8) 10d x 1 1/2" HDG NAILS, WOOD TO WOOD: MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN. SIMPSON H10A OR LGT2 W/ 10d x 1 1/2" HDG NAILS, FILL ALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE 1 MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, < a" ■ COLUMN SCHEDULE MARK SIZE & BASE PLATE OR REMARK DESCRIPTION REINFORCEMENT 4X6 (3Y"x5Y") SYP. HTT4 W/5/8" DIAx5" 5/S3.1A WD 1 PT., WOOD POST EXP. BOLT CONNECTERS ARE TO BE GALVANIZED. 6. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE CONCRETE LINTELS: 7. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND GIRDER/TRUSS TRUSSES W/2x4 w/2x68oTTOM CLEAR SPAN OPENINGS. BOTTOM CHORD B. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). CHORD Co L0 DO C0 9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE U 0CMI DESIGNED UNDER THE ASSUMPTION THE v v U ., SUPPORTING STRUCTURE HAS FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEERS REVIEW AND APPROVAL. - 10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILTI X ZF POWDER ACCTUATED wF FASTENER, ZF 72 P8S36, .177" ° x 2 7/8" LONG, WITH WASHER @ 16" O.C. 11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 12. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. 13. ALL ELEVATIONS ARE REFERENCED FROM U-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. 14. BOTTOM CHORD BRACING, DIAGONAL BRACING AND GABLE END BRACING SHOWN ON THE FRAMING PLANS AND DETAIL ARE DRAWN AS A DIAGRAMMATIC PURPOSES FOR MINIMUM SPANS AND MAXIMUM SPACING. THESE DRAWINGS ARE INTENDED AS A GUIDELINE FOR CONSTRUCTION AND DO NOT NECESSARILY REFLECT ALL ACTUAL CONDITIONS THAT MAY ARISE IN THE FIELD, FIELD CONSTRUCTION SHOULD CLOSELY PARALLEL THE BRACING DIAGRAMS WITHIN THESE MINIMUM AND MAXIMUM TOLERANCES. ADJUSTMENTS IN THE FIELD ARE ACCEPTABLE FOR FIELD CONDITIONS SUCH AS INTERFERENCES WITH TRUSS WEBBING, SHEETING ETC. IN SITUATIONS WHERE THE DIAGRAMS LOCATION AND ACTUAL TRUSS WEBBING CONDITIONS CONFLICT, THE CONTRACTOR SHALL PLACE THE DIAGONAL BRAE ADJACENT TO THE TRUSS WEB AS CONDITIONS ALLOW. 2x4 SCAB NAILED TO /I DIAGONAL END JACK TRUSS BOTTOM IIC/X�\II BRACING/BOTTOM CHORD W/MIN (4) 10dCHORD BRACING IRE APPLICABLE NAILS FOR EACH CHORD CONNECTION DISSIMILAR BOTTOM CHORD, BRACING @ END "' FOR EACH CHORD CONNECTION nTSc;TMTT.AR BOTTOM CHORD BRACING ® MID RUN CONTROL DATE. 01/21/2021 CONNECTOR SCHEDULE MiTek USP SIMPSON MiTek USP SIMPSON DES. UPLIFT .GRAVITY DES.. UPLIFT GRAVITY FASTENER FASTENER (S)10d X 11/2" 1-PLY, (7) 16d 2-PLY,EMBED 4' (8)1Dd x 11/2 1 PLY,(6)16d 2-PLY, EMBED 4' 8 1625 META-16 1450 (2) META-16 1985 (12110d x 11/2" 1-PLV, EMBED 4"(10) lOd v 11/2 1 PLY; EMBED 41870 6-18 2430 X11/2",(8) 16d2PLY, EMBED 4' (9)10d x 11/2 1PLV,(8) 16d2PLY, EMBED41870 HETA-16 1810 (10)1od 11/2", (8)16d 2-PLY, EMBED 4" (9) 10d x 11/2 1 PLY, (8)16d 2-PLV, EMBED 42035 HETA-20 1810 (10)10d x (12)10d x 11/2", 1-PLY, EMBED 4" (10) 10d x 11/2 1 PLR, EMBED 4" 2500 (10)16d 2-PLY, EMBED 4' : (12)16d 2-PLY, EMBED 4' P16-18 20 2430 (2)HETA-20 1885 BLK (511/4 x 3" ,,d,,B.1, Anchors; WOOD (16)10d (7)-1/4".x 21/4" TTTEN, WOOD (16)1Gd Z 1655LGF-2 3480 CONC (4) 3/8" X 5" Wed a BoIY+Anchors;WOOD (12 W525 g ) (12) SDS 1/4'k3"TO GIRDER, (4) 3/8'x 5"TITEN HD TO WALL O 33W LGT3-SDS2.5 (16) -10d x 11/2,1 PLY ALTERNATE USE OF (21 HTA-20 ACCEPTABLE (1S) -10d x 11/2, 1 PLV ALTERNATE USE OF (2) HETA-20 ACCEPTABLE 2430 DETA620 2480 < (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED), (22)10d TO WOOD) (1) 5/a'ATR IN HIGH STRENGTH EPDXY (MIN. 12" EMBED(; (22110d TO WOOD + 3945 MGT+ 3965 WOOD(a) 10d, MASONRY(2) 3/4"A.T.R (2)3/4"gTR.IN HIGH STRENGTH EPDXY (MIN. 12"EMBEDI, (16) 10d TO WOOD - HUGT2+ 9575 HGT-2+ 10690 WOOD 10d. MASONRY (2) 3/4"ATR (2) 3/4" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED), (16)10d TO WOOD HUGT3+ 9860 HGT-3+ 10690 (8) 1510 PARALLEL TO WALL LTA2 1210 PARALLEL 1210 PERPENDICULAR TO WALL TO (10) 10d x 11/2"' (10) 10d ti 1-1/2" LPTA PERPENDICULAR TO WALL WALL VGT 4WD (1)5/8"A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED), (4) 10d TOP/(6)10d FACE/(12) 10d BACK OF TRUSS (1)5/8'.A.T.R. IN HIGH STRENGTH EPDXY (MIN. 12" EMBED), (16) SIDS 1/4"x3" MUGT15 3940 IN HIGH STRENGTH EPDXY (MIN. 12"EMBED),(8)10d (2)5/8"AT.R. I N HIGH STRENGTH EPDXY (MIN. 12" EMBED),(321 SDS 1/4"xT' HUGT 9575 (2)VGT 7185 (2)5/81,A.T.R. MTW 12 965 MTS-12 990 (14)10d x 11/2", (14) 10d kk (14)10d X 11/2 HTW 16 135S HTS-16 1310 (16)10d X 11/2", (16) 10d (16)10d X 11/2 HTW 20 1355 HTS-7D 7310 (24) 10d %11/2", (20)10d (24)10d X 11/2 HTW 24 1355 HTS-24 1310 (24)10d X 11/2", (20)10d (24)10d x 11/2 LSTA 12++ 930 LSTA-12 «* 925 (10)10d (10) 10d LSTA 1S++ 1235 LSW-18 ++ 1235 (14) 10d (14) 10d MSTA-18, 1310 MSTA-IB+. A15 (14) IOd (14110d MSTA-24++ 1640 MSTA-2A ++ 1640 (18110d (18) lOd MSTA-30++ 2065 MSTA-30 ++ 20 00 (22)10d (22)lOd MSTA-36++ 2065 MSTA-36 ++ 2050 (26) 10d ` (2G)10d iSFI236. 2765 MSNA6 3800 (36)10d X 11/2' (48110d X 11/2 5070 (48)10d X 11/2' (481 KTSI248 51D5 MSTI-48 (16) Ed 11/2"; (16) Ed) d TO LATE (8) Ed TO PLATES, (8) Ed TO STUDS LFTA6 980 H6 105S.. (6)10d TO STUDS (6)10d TO PLATE (6110d x 11/2 TO STUDS SPT4 875 SP4 825 430 (4)Edx11/2" TO BEAM, (4) 8d x 11/2" TO POST. (4)Ed x 1 1/2TO BEAM,(41 Ed x 11/2" TO POST. MP34 525 IN F1@I60% A34 (10110d x 11/2"TO MUSS, (10) 10d X 11/2"TO PLATE (12110d X 11/2 HHCP2 680 HCP2 -590 H1DA 1040 19)10d x 11/2" TO TRUSS, (8)10d X 11/2 TO PLATE (18) SOd X 11/2 RT16A 1020 '4940 (28)lOd TO TRUSS, (10) WS3 WOODS[REWSTO POST W/5/B"THREADED ROD (16)-SDS1/4x3 TO WOO D(10)-SDS 2/4"x21/2'W/ TH READED ROD. (2) N UTS/WASH ER/2 PLY MUGT15&PHD4A 4175 VGT&MDU4 4940 (28)10d TO TRUSS, (10) WS3 WOOD SCREWSTO POST W/5/S"THREADED ROD (I6)-SDS}/4x3"TO WOOD, .(3)-3/4"STUD BOLTS W/THREAD ED ROD, (2) NUTS/WASHERf2PLY MUGT15&PHD4A I 4175 VGT&HD7B 2300.. 7]50 (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED) IN CONC., (12)16d TO. WOOD (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY, (MIN 7" EMBED.) IN CONC (12):1Gd TO WOOD ppOgq 2535 6]]5 ABU 442 2190 18205 11) 5/8" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED) IN CONC,(12)16d TO WOOD (1)5/8"ATR IN HIGH STRENGTH EPO%V,.(MIN.7"EMBED.I IN CONC.,(12)16dTO WOOD PAU66 y 2455 16W5 ABU BE 1310 111,3/4" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED) IN CONC:, (8)10d TO WOOD (1) 3/4" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. ]" EMBED.) IN CONIC., (8)I0d TO WOOD on LT519+++ 1205 LTT19 ++* 1500 (1) 3/4" A.T.R. IN HIGH STRENGTH EPDXY, (MIN. 7" EMBED) IN CONC.,(10)IOd x 1-1/2TO WOOD (1)1/2".ATR IN HIGH STRENGTH EPDXY, (MIN.]"EMBED.)IN fONC,(ID)10d TO WOOD O LT5208 i-.+ 1100 LTT208-- 4455 (1) 5/8." A.T.R. IN HIGH STRENGTH EPDXY (MIN. 7" EMBED) IN CONIC., (18)16d X 21/2" (1) 5/8" A.T.R. IN HIGH STRENGTH EPDXY (MIN. 7" EMBED,) IN CONC., (26)16d X 21/2' - x HTT45 4160 HTT4 IN HIGH STRENGTH EPDXY (MIN. 7' EMBED) IN CONC, (26116d X 21/2" (1)5/8 ATR.iN HIGH STRENGTH EPDXY (MIN. 7" IN CONC., (26)16dX21/2" QHTT45 3005 HTT5 5090 (1)5/8"A.T.R. HHD011-SDS 11810 (1)1"A.T.R. IN HIGH STRENGTH EPDXY, (MIN.10" EMBED) IN CONC.,(,4) WS3 WOOD SCREWS (1)1 ATR IN HIGH STRENGTH EPDXY, (MIN 10"EMBED.) IN CONC.,(24) SDS%"x 2Y,"WOOD SCREWS UPHDll+ 14395 2.5+ (1)5/8" A.B. IN HIGH STRENGTH EPDXY, MIN 7" EMBED) IN CONIC:(14 WS3 WOODSCREWS ( (3)7/8 A.B.IN HIGH STRENGTH EPDXY, (MIN. 7"EMBED.)IN CONC, (3)3/4" STUD BOLTSTO WOOD PHDSA 6525 HD70 EMS 1117/8" A.B. IN HIGH STRENGTH EPDXY, (MIN. 7' EMBED) IN CONC. (3) 7/8" STUD BOLTSTO WOOD TDXB 7870 (1)1%2"'.1-BOLTW MIN G" EMBED &NOT LESS THAN 4"FROM EDGE OF CONC W/3/4"CIA ITW ftAMSET/REDHEAD (1)3/4 A.T.R.IN HIGH STRENGTH EPDXY,(MIN.6J5"EMBEDMENTJINC.M.U. TOP, (1)3/4"A.T.R IN HIGH STRENGTH. NFM35X12U 2590 7130 MBHA 3.56/11.25 3475 5330, DVNA BOLT SLEEVE ANCHOR OR EO W/MIN S"EMBED INSTALLED IN FACE. (19)IOd AT 1018T EPDXY, (MIN, 6]5"EMBEDMENT) IN C. M. U. FACE, (18)10d TO BEAM 2710(100%) HUSC412 2635(100%)(10) (10) 16d'.. TO HEADER '(10) 16d TO WOOD H U54121F 3G15 '.. 3435 16d TO HEADER, (10) 16d TO WOOD 3325(125%) (WOOD). 3220(125%) C' HUC410 (18)1/4 x3"' W53 SCREWS, (10) 10d TO (18)1/4 x23/4 TITEN(9 PER FLANGE). TO CMU, (10) 10d TO WOOD, HD4101F (CMU) 1950 3080 (CMU) 1800 4500 WOOD. USE (20) 3/16"" TAPPER+, (10) 10d TO WOOD Z HUC210=2 (18)1/4 'x 3"'WS3 SCREWS. (10) 10d TO - (18) 1/41' x23/4 TITEN(9 PER FLANGE) TO CMU;(10) 10d TO WOOD: S HD210-21F (CMU) 1950 3080 (CMU LL- 1900 4500 WOOD. USP (20) 3/16"" TAPPER,, (10) 10d TO WOOD HUC214-3 1800 4500 (1S)1/4 x 3"" WS3 SCREWS, (10) 10d TO (18)1/4x 2 3/4 TITEN. (9 PER FLQNOEI TO CMU, (10)10d TO WOOD. HD210-31F (CMU) 2795. 5015 (CMuy I I IWOOD. USP (20) 3116 " TAPPER+, (10) 10d TO WOOD 1430 5595 (4)3/8"X4"Wedge-Bolt+ Anchors, WOOD (4) WS3 WOOD SCREWS (4)3/8 s4TITEN HD ANCHORS(26E(i FLANGEI TO CMU, (4)1/4X2-1/25D8 SCREWS TO WOOD. LGUM26-2 2125 6065 LGUMM-2-SDI 1 1 1A O 4 CJ1 CJ" Y i0 u n u n n u n n n EJ7e n n n n n n u IL 11 n n n n n u n n n u n u u u II = r II II II II If II (I II II (I II If II II A8G �Q GT A7 IA5 I 83.1--- A4 IA3 PRE -FABRICATED I1OOF A2 TRUSSES @ 24" O.C. - A---- ----- RIDGE- ----- -- - A3 �Q 22"X3077-7-==_- --__ATTIC I P A4 _ CCESS _ _. A5�-== LL / y1I1IF- �1I GT II I F B1 n n n II II II _ CJ5 - B2G GT - c� II II II NII NII NII CJ3- CJN wll WII CJ5 = u n n n n CJ3i II II I� ti cJ1 EJ7 I 1� ,- II II IL II �, cJ 1 I A _ 53.1 co Co ROOF FRAMING PLAN SCALE: 14" = V-0" 11 II IL _ __. II J II Co u - --- - -- CJ1 CJ3 0 CJ5 CJi iC g rJ O O O m o [[ N�1 O V LL (D J Z_ ZU a O m o Tr 1 '.09�d m b � N O J LL -j Z Z U Q OCE El O I` IDReviewed for Code Compliance Universal Engineering Sciences 2194 H WY ALA, SUITE 301 , INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321,$02-3591 www.abdesigngroup.com AA #: 0003325 r U W 4 A Cr A ti SLTBDIV. 8e an" CREEKSIDE PHASE 2 LOT #83 PROJECT* 04321.200 083R1 MODEL 4EHB 2605-HAYDEN GARAGE SWING: LEFT PAGE: <,r ROOF FRAMING PLAN AND NOTES 160 MPH EXP. C)` ARCHrrEC3 STATE OF FLORIDA MAR 2 2 2021 rMICHAEL C. ANDERSON AR NO 17305 PRINT DATE 03 19 21 SCALE: 1 /4"= V - 0" SHEET S 6 GABLE END a 3E 2N 3R 3R 2N 3E v 19 o0 0 v V 00 o v v 0° 0 V v 0 o v v 00 o v 19 2E tO (2,^RRL^�I. 2R 1O 2E , C,•, „ .. , ,. A r A A A r V 19 °° 0 V v °0 0 7 v V 19 °O 0° V v 0°0 0° v v °o ° o° v V OO°O0 0°O v 9� ° ® 2R 0 V 2R o ° ° , V O00 O °0 V 19 0 2R 2R ° V 0°O 00 0 00O°00 V 19 V 0° 000 V v �0000 V a 3 v v v v v v vla 2E vV V v V VQil 3. a k*I HIP ROOF ROOF WIND DESIGN PRESSURES NET (GROSS) ASCE 7-16 ZONE 1 = 58.00 PSF (68-00) ZONE 3 = 66.50 PSF (76.50) ZONE 2e = 66.50 PSF (76.50) ZONE 3e = 76.60 PSF (86.60) ZONE 2n = 76.60 PSF (86.60) ZONE 3r = 91.70 PSF (101.70) ZONE 2r = 76.60 ESE (86.60) "A"= 4'-0" END ZONE DISTANCE BASIC WIND SPEED: 160 MPH EXPOSURE CATEGORY: "C" RISK CATAGORY: II APPLICABLE INTERNAL PRESSURE COEFFICIENT: +/- 0.18 ROOF DIAPHRAGM ROOF/ WALL/ FLOOR FOR ASPHALT SHINGLE ROOF, USE MIN 7/16" STRUCTURAL SHEATHING EXP 1(24/16) or 15/32" STRUCTURAL SHEATHING EXP 1 SHEATHING (32/16), FOR CEMENTITIOUS TILE AND METAL ROOFING, USE 15/32" STRUCTURAL SHEATHING EDGES ACING) SEE DETAIL. XP 1 (3216) :(SEE TABLE FOR FIELD AND FASTENER SCHEDULE ROOF SHEATHING TO GABLE END FRAME USE 8d RING SHANK GUN NAILS @ 4" O.C. EDGEWISE 2x4 BLOCKING ALL PANEL JOINTS W1IN 4' NAIL REQUIREMENTS OF GABLE END. SIZE HEAD" LENGTH DIA. TENSILE STR. SHANK ASTM 8d RING SHANK, 23/8" 0.113 170,000 RING (16-20 RINGS F1667 RSRS-01 SCREW SHANK PER INCH) 8d RING SHANK, 2 3/8" 0.113 F1667 PNEUMATIC RSRS-01 SCREW -NAILS EXTERIOR SHEATHING USE 1/2" CDX OR 7/16" O.S.B. PLY WITH 8d RING SHANK GUN NAILS AT 4" O.C. AT PANEL SIDES AND 8d RING SHANK GUN NAILS 4" O.C. TOP & RAFTER OR TRUSS BOTTOM PANEL AND 8d RING SHANK GUN NAILS AT 6" O.C. AT ROOF SHEATHING INTERMEDIATE SUPPORTS OR 7/16" ZIP SHEATHING SYSTEM (INSTALLED PER MANUF. SPECS.) SEE DETAIL. - f z_= ROOF SHEATHING ATTACHEMENT SPACING „ .C, IN FIELD -� -- ZONE 1. Sd NAILS @ 4 O.C. ON EDGE AND 6" O I , ZONE 2e, 2n, 2r: Bid NAILS @ 4" O.C. ON EDGE AND 4" O.C. IN FIELD — - -- m ZONE 3,3e, 3r: 8d NAILS @ 4" O.C. ON EDGE AND 4" O.C. IN FIELD BUILDING LENGTH p NOTE: ROOF SHEATHING THICKNESS WAS CALCULATED F OOF SHEATHING LAYOUT AND ADHERES TO ASCE 7-16 AND ENDWALL BRACING FOR GABLE END FRAMING NOTE: GABLES DROP GABLE END & (1) ADD'L DROPPED TRUSS 2x4 #2 SYP OUTLOOKER RAFTER W/ BLOCKING @ 16"O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING @ 16,0 O.C. FIRST 4 BAYS W/ (2)12d NAILS EA. END- ATTACH ROOF SHEATHING TO RAFTERS 21 BLOCKING PER NAILING SCHEDULE 8d RING SHANK GUN NAILS 9 4" O.C. TOP &BOTTOM EDGES U) 7I a J Z W 0 I/l W zV� =O U) Z CE 'a J a Z Z ^ I/ \ zLU ¢ O , J E: z Z V . O a @) TYP. EXT. SHEATHING ATTACHMENT TYP CBid RING SHANK GUN NAILS SEE "ROOF SHEATHING ATTACHMENT" TABLE FOR FIELD SPACING IT FOR STRUCTURAL ROOF C#8 2" DECK SCREWS @ 6"-8" O.C. MAX @ EDGES & 12" O-C. MAX IN FIELD. UNTHREADED SHANK TO EXTEND BEYOND THICKNESS OF SUB -FLOOR SHEATHING TRIP. 3/4" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS GENERAL NOTES: ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C331C33M. MAXIMUM AGGREGATE SIZE SHALL BE 34' STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND - IA/nhn' - ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT PROVIDE 6%AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR 1NEAIHER - ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS`. FBC-R 2020, 7th EDITION ALL EXPOSED EDGES OF CONCRETE ARE '0 BE CHAMFERED 3.4 _ ACI 318-14, BUILDING CODE REQUIREMENTS ARC H I T E CTs - FOR STRUCTURAL CONCRETE, TMS 402/602-16 AISI SPECIFICATION FOR THE DESIGN OF PROVIDE 6-MILCONTINUOUSPOLYETHY LENF VAPOR BARRIER PAFA4BR9NE UNDER ALL SL4B5-ON-GROUNDNIW - - - - COLD FORMED STEEL STRUCTURAL MEMBERS 2016, ASCE 7-16 AND AISC. SPECIFICATIONS DRAWINGS. SEAMS LAPPED 6 INCHES AND "F AL.ED WITH ADHE^.IVE TAPE. ALL DETAILS. AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND FORM -WORK: ,7 SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR. SITUATION ELSEWHERE ON THE PROJECT, FORM -WORK, SHORING, AND BRACING FOR ALI CONCREI E BEAMS,SLABS, COLUMNS, WAL ft si n EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. - AND FOOTINGS SHALL BE DESIGNED AND CONS 1"RI ICTED IN ACCORDANCE WITH ACI 347 LF Group,,. EDITION,"RECOMMENDED PRACI ICE FOR CONCRETE FORM -WORK. ` ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE DRAWINGS: FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BEROUGHT EXCLUSIONS FROM THESE PLANS: Aril 21; 2021 p 2 2194 HWY A1A, SUITE 301 F ARCHITECT PRIOR TO PROCEEDING WITH THE PART TO THE ATTENTION O THE AR C WATERPROOFING, FLASHING, SOUND ISOLATION. FIRE SEPARATION, OR OTHER NON STRC - INDIANHARBOUR BEACH, OF THE WORK. ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUC - Planning & Development Services '.. ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE Building & Code Regulation Division $ g FLORIDA 32937 THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING - PH:.321-802-3591 IS COMPLETE. IT IS THE CONTRACTORS RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND 2300.Virginia Ave. www.abrSigngrOup. m SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS WELDED WIRE MESH: FOrtIPlOrce; F1:-349$2 - AA., 0003325 DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, ,., . 772 462 2172 �:. TEMPORARY BRACING, GUYS OR TIE -DOWNS. WELDED WIRE MESH, SHALL BE / I A I CrWA 1064M. (,RADE 65 AND BE PLACED IN ACCORI- - ACI. TYPICAL DETAILS. MINIMUM I Al ^IiAI-I BE ()NF SPACE PLUS TWO INCHES. WIRE MESH THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION BE SUPPORTED WITH 2' CHAIRS SPACED :i' o" OC:. EACH WAY. RE:. Permit # REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. D.R. Horton Homes - DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR REINFORCING. STEEL: Creekside Lot 83 TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. REBAR SHALL BE ASTM A615A615M GRADE 40 IN CONGRE rE DEFORMED BARS, REBAR SHA - Response Letter GRADE 60 IN MASONRY DEFORMED BARS, FREE FROM OIL:., SCALE, AND RUST AND PLACEC - DESIGN LOADS: W/ THE TYPICAL BENDING DIAGRAM AND PLACING DE rAll S OF THE ACI STANDARDS AND S CONTRACTOR SHALL SUBMIT REBAR. SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATIC ,_. :. ..: For the above listed project, the plans indicate 7/14" roof sheathingonsheet SlNl1. AND BARS SHALL LAP 6 x,BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ROOF LIVE LOAD FLOOR: LIVE LOAD 40 sf p REVIEW. ' This iSa$error on the plans. The correct ca110Ut Shall be 19l32" Sheathing thickness and 20psf TOP CHORD -non-concurrent TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR 25" #6 BAR 36 - the correct reference.. for Wind pressures is ASCE 7-16 reference. . 10psf BTM CHORD -non-concurrent #5 BAR 30" #7 BAR 42" - - - PROVIDE 36" x 36" CORNER BARS, BOND BEAM ONLY. LAPPED AND TIED TO EACH BEAM REI DEAD LOAD DEAD LOAD FOR ADDITIONAL INFORMATION. _ pat TOP CHORD psf TOP CHORD (7 psf wT HALT SHINGLES) (1 psf w/ No GYPCRETE) (7 ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOO p 5 psf BTM CHORD - 10 psf BTM CHORD 5 THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTC DEAD LOAD TO RESIST WIND UPLIFT: 11 MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT TH BALCONY LIVE LOAD 60 psf WALL. STAIRS LIVE LOAD 40 psf ST WIND: DEAD LOAD SPEED 160 MPH 3- SECONDCRISK RUN REINFORCING BARS CONTINUOUSLY LAPPED Al SPLICES AND AROUND CORNE C,RISK CATEGORY II) (ASCE 7 16 (FBC R2020) EXPOSURE , CA INTO INTERSECTING WALLS AND HOOK AT ENDS- STAGGER SPLICES WHEREVER PC LIVE LOADS: UNINHABITABLE ATTIC WITHOUT STORAGE: 10psf, UNINHABITABLE ATTIC WITH LIMITED STORAGE: 20psf,.HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS: 30psf, BALCONIES (EXTERIOR) DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION Of AND I DECKS:: 40psf, GUARDS AND HANDRAILS: 21 GUARD IN -FILL COMPONENTS: 50psf, PASSENGER WITHOUT THE APPROVAL OF THE ENGINEER. VEHICLE GARAGES: 50psf, ROOMS OTHER THAN SLEEPING ROOM: 40psf;SLEEPING. ROOMS: 31 STAIRS: C `• a P + k r I 4 7 , d `s 7 IjI > B Y I I t WS 40sf P MASONRY: MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OI SHOP DRAWING REVIEW: "SPECIFICATION MASONRY. STRUCTURES" (TMS 402. BUILDING CODE REQUIREMENTS FOR.I' .SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE. WITH THE DESIGNING INTENT STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES), A k OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY -OF THE CONTRACTOR TO VERIFY THE MASONRY STANDARDS JOINT COMMITTEE. - Should you have any questions, please feel free to contact rile. II COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. ALL BLOCK WALLS SHALL BE TWO CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BE( G.I ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT. MANUFACTURED IN CONFORMANCE WITH AS R',4 C 90, GRADE Nn = 2000 PSI. BLOCK SHALL Sincerely - _ . ('I DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED.. SHOP DRAWINGS IN THE FORM RUNNING BOND UNLESS OTHERWISE NOTED. I AY I IF MASONRY WALLS TO BOTTOM OF TIE - - (I OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON -TRACT DOCUMENTS) ARE PROHIBITED PLACING CONCRETE FOR IN -WALL COLUMNS. (,ROUT USED TO FILL MASONRY CELLS SHA ASTM C-476, AND SHALL PROVIDE A MINIMUM OMPRESSIVE STRENGTH OF - ' - �i --- ` a WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER. IN ALL INSTANCES, THE CONTRACT C3000 PSI AT 28 -_<�� - � I. DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS CHECKED, UNLESS OTHERWISE SPECIFIED IN SPECIFICALLY NOTED OTHERWISE ON FOUNDA I ION PLAN. THE GROUT MIX SHALL HAVE A - COURSE AGGREGATE, AND SHALL RE PLACE[) S W A L OF 8TO 10. USE ONLY MECHA I IMP " "Dp _ WRITING BY THE ARCHITECT. A _ PLACR 2 TO CONSOLIDATE GROUT. �� _ , FOUNDATION/ SITE PREPARATION: -- - TYPE "M" OR "S" MORTAR SHALL RE IJSEI) EXCLI ISIVEt Y ON THIS PROJECT, MORTAR SHALI FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 psf, FOOTING PROPORTIONED. AND MIXED AS OUT[ INED I INI T R ASTM C 270. HORIZONTAL AND VERTICA IVLI - -el C. AriderSOni''': EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 95%OF THE SHALL BE 3/8" THICK UNLESS OTHERWISE NO1FD. REMOVE MORTAR PROTRUSIONS THAT �- MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WITH ASTM D-1557. TREAT ALL CELLS TO BE FILLED. FlOiideAT6hitect A'k05 I' SOIL FOR TERMITE PROTECTION. - - - FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS ANC , THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY REINFORCING. SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE GEO-TECHNICAL ENGINEER'S REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE LAP VERTICAL REBAR 6 X BAR NO. i4n BAR DIAMF FFRSL, I J.N.O.. 2194 Hwy AIA, Suite 301 Indian Harbour Beach, FL 32937 • Phone: (321) 802-3591 CONTRACTOR'S EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE www.abdesi 1 MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL gttgroup.com ' 8E. MADE BY THE GEO-TECH. ENGINEER. STRUCTURAL STEEL:Emommommom x,_ THE MATERIAL, FABRICATION, AND ERECTION OF STRt1C1URAL STEEL SHALL COMPLY WITH THE CONCRETE: SPECIFICATIONS FOR THE DESIGN. FARRICATIc1N AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS.. _-SUBDIV 7AT: 9TH EDITION, BY THE AMERICAN INST ITUTE OF':I FFL CONSTRUCTION. STRUCTURAL STEEL SHAI L RE AS I M CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS: A36/A36M, Fy = 36 ksi FOR ANGLES, PI ATFS. AN[) W SHAPES: STRUCTURAL TUBING SHALL BE ASTM (v Tj�1 T7� A500/A500M, GRADE B, Fy - 46 ksi STRI ICTURAI PIPE SHALL BE ASTM A53:'A53M, GRADE B, TYPE E OR S. I y - C REEKS IDE ' 2,500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE 35 ksi. TUBE AND PIPE COLUMNS SHALI- BE CONCRETE FILLED IN THE SHOP. c�1 3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE SLAB. PHASE 2 - ANCHOR BOLTS AT THE COLUMN BASES SHALI BE AS FM A307 BOLTS WITH DOUBLE -NUT LEVELING ALL - LOT rP Q CONTRACTOR SHALL SUBMIT PROPOSED MIX DESIGNS, WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MIX PRIOR TO OTHER BOLTS SHALL BE ASTM F3125�F3125M BOLTS WITH. WASHERS UNDER THE TURNED ELEMENT ROL.1 S L 1 # U 3 ' CONCRETE PLACEMENT. CONCRETE SLUMP SHALL NOT EXCEED 5"+1- PRIOR TO THE ADDITION OF PLASTICIZER. SHALL BE TIGHTENED IN ACCORDANCE WITH THE TURN OFF -THE -NUT METHOD. r.19 a CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 318 AND ASTM C941C94M OR MEASURING, MIXING, TRANSPORTING, ALL ANCHOR BOLTS SHALL BE GALVANIZED STEEL. J BOLTS ARE TO BE STEEL PROJECT* '? ETC. CONCRETE TICKETS SHALL BE TIME -STAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM WHEN 04321. 200 0 U 3R1 WATER IS ADDED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. IF FOR ANY REASON - MODEL,. THERE IS A DELAY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL BE THE. RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY 4 EI HB rX NON COMPLIANCE WITH THE ABOVE. IT REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS: /� "26O5-HAYDEN" A. 3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH (FOUNDATIONS):+, GARAGE SWING: B,. FOR CONCRETE EXPOSED TO EARTH AND/OR WEATHER: Reviewed for Code l Compliance ompli 1-1/2' FOR #5 AND SMALLER CLEFT 2" FOR #6 AND LARGER Universal Engineering C. FOR CONCRETE NOT EXPOSED TO WEATHER - Sciences PAGE,: 3/4" FOR SLABS, WALLS AND JOISTS 1-1/2" FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRRUPS IL FASTENER SCHEDULE APPLICATION sPF TJE SPACING RFHAPP APP,. I(:ATION - Sor TYPE SPACING REMARKS 1x2 PT FURRING TO 0A`,F HARUENFD,-+Ill fl'OIC I AFNS_ F DpOR SLICK V4"DIA. TAPCON MASONRY 11/2" EMBED., G END DIST, MASONRY CON.. / C 1 1I t r N : JI I 'I T ^, r dA..O JR BC, ,MC NO WASHER FASTENER 8'DID I +12" EDGE DIST, SGD. AL. EXT. DOOR'! ,. A'E IIAC RFNFD '.� ,II 8" O/C WINDUV✓ U C Fn-,.IPiIFR ;ARAGE RUCK 3,13 UTA. OR (3/B' DIA) q" EMBED., END DIST., I PT, SEE NOTE e PIAp I:"IN5; I' STAGGERED INi,>t�A. NP/ .,>L'. T MAGUPIRf:GUNC. V2' DIA EXPANSION BOLT 24O/C 24" O/C (V2" DIA) 3" EDGEE DIST. w/ WASHER WINDOW BUCK I IIAnDPNFD, I Ill 4'o/C WINn"V, r ,r F .IFIIFt, MFTA(.;TRAPTO CONTACT THIS ENGINEER FOR SPACING ix PT, SEE NOTED 6IAII I I gTAGGERED MA ONRI/CONC.. REQUIREMENTS EXT. SWING DOOR I'I Iri'nA TAPION' I I:' F, r<FI " FIII 1 I RFARINO WOOD 1 2'" EXPANSION - 4' EMBED. 4' END BUCK 2x PT, SEE NOTF9 IA, NA1LFP FA',TNER Je'O/C n1,( Ft5.F111 I ,r, I_ TO CONIC SI AS W/ WASHER BOLT 24"O/C DIST.; 3" EDGE DIST. 2x PT WINDOW BUr:K ' ' I O/C A" I I r' PTTO STEEL COL. SFF " I"J^AF HFn ^,TAGGERFD �F t'ds,r Fill F)1 ill NOTE6- NOTES 1. STAPLES SHALL NOT BE IISEU FOR ANY STRUC FURAL APPLICATIONS 2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS GHAI I. BF AS PER MANUFACTURER'S SPECS AND /OR NOA 3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED 4. RAF SHALL BE HILTI X-ZF HEAVY CUT PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN 5. FASTENER SPACING FOR THE ®LICKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE ;PACIN(� DE NLED ABOVE 6. WINDOW AND DOOR BUCKS 61IAL1 RE AS WIDE OR WIDER AS THE DOOR OR WINDOW FRAME FXCFI I FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. lx MEMBERS ARE NAILED AND 2x MEMBERS ARE SECURFD W! TAFCONs OR PAP TO THE SUBSTRATE. DETAILS ,i I 60 MPH EXF ` ARCHII-Ill 44 MAR 2 2 2021 Mill C. ANDERSON AR NO 17305 DATE: 03/19/21 SCALE: 1/4"=,1' - 0" SHEET 6._J I