Loading...
HomeMy WebLinkAboutSurveyR=2 —19' =67 ' e 0 P __ _ ----- 5.00' - o_ o w a� r ;-0 IA .? CL CUL D AC2 BENCHMARK SANITARY MANHOLE SS-51 RIM EL=17.11' N.A.V.D. 1988 i FLOOD Z0 E X ROM PROPOSED SANITARY SERVICE 84 VACANT N37'58'17"E 130.00' 0) PROPOSED A/C PAD POSED 83 ERED VACANT RY PROPOSED 1_4.00�GARAGE MODEL 4EHB/H F.F.E.=19.09 F.F.E.=18.59 EXISTING BUILDING PAD EL=18.90 Nr- R=200.00 A-5'52'33" _ L=20.51' TO PT THOMAS P. KIERNAN Professional Surveyor & Mapper Florida Certificate' No. 6199 .6 -,Z,.:> DATE PROPOSED COVERED LANAI LA OOOF 1 OO A •'.ti ,1 � : i D '_5_�____ I cilip SiDES VA7 GRAPHIC SCALE 20 0 10 20 IN Far SET 5/8" IR/C i Inch v Pa r< LB 4286 (TYP) PROPERTY ADDRESS o% 3349 TRINITY CIRCLE, FORT PIERCE, FLORIDA WATER LEGAL DESCRIPTION MANAGEMENT TRACT 1 Being all of Lot 83, according to the plat of CREEKSIDE PLAT NO. 4, as recorded in Plat Book 85, Page 5, Public Records of St. Lucie County, Florida. SET 5/8- IR/C Containing 0.269 acres, more or less. LB 4286 (TYP) 16. loPR, 11 F\ J PROPOSED WATER SERVICE SET 5/8" IR/C ALB 4286 (TYP) LOT 83 AREA SUMMARY IN SQUARE FEET SOD: 9572f DRIVEWAY/WALKWAY: 704± ADD LOMA INFORMATION I JDJ 1 6/23/21 LEGEND & ABBREVIATIONS BB DENOTES BEARING BASE CBS DENOTES CONCRETE BLOCK STRUCTURE C DENOTES CHORD BEARING do DISTANCE DENOTES CENTER LINE D.E. DENOTES DRAINAGE EASEMENT F.F.E. DENOTES FINISH FLOOR ELEVATION FND DENOTES FOUND IR/C DENOTES IRON ROD AND CAP L.B. DENOTES LICENSED BUSINESS L DENOTES ARC LENGTH N/D DENOTES NAIL AND DISK O.S.T. DENOTES OPEN SPACE TRACT P.S.M. DENOTES PROFESSIONAL SURVEYOR do MAPPER P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR R DENOTES RADIUS R/W DENOTES RIGHT OF WAY U.E. DENOTES UTILITY EASEMENT W.M.T. DENOTES WATER MANAGEMENT TRACT A DENOTES INCLUDED ANGLE DENOTES DRAINAGE FLOW l DENOTES PROPOSED ELEVATION GENERAL NOTES 1. The last date of field work was 5-14-20 2. Additions or deletions to survey maps or reports by other than the signing party or parties is prohibited without written consent of the signing party or parties. 3. Reproductions of this map are not valid without the original signature and raised seal of a Florida Licensed Surveyor and Mapper. - 4. Lands shown hereon were not abstracted by this office for rights —of —way,. easements of record, ownership, abandonment's, deed restrictions, or Murphy Act Deeds. This information should be obtained through appropriate title verification. 5. All above ground fixed improvements, if any, have been located and shown hereon. 6. Underground foundations and improvements were not located as part of this survey. 7. Flood Note: By graphic plotting only, the portion of this property scheduled for building improvements is in Zone "X", according to the LOMA Case No. 21-04-138A associated to the Flood Insurance Rate Map, Community Panel No. 12111CO170 J, effective date February 16, 2012. The exact designation can only be determined by an elevation certificate. There may be additional map Amendments affecting this property. 8. The bearings shown hereon are based on Plat information and are referenced to the Easterly line of Lot 83 which bear South 09'00'15" East and all bearings are relative thereto. 9. No easements are shown hereon other than those depicted on the plat. No search of the public records has been performed to find additional easements that may exist. 10. Elevations shown hereon are based on the North American Vertical Datum (N.A.V.D.) 1988. 11. The building setbacks shown hereon, although based on the best available information, are not certified to and must be verified prior to design or construction. RECEIVED PF JUL 2 1 ?1171 0 Permitting Departmt_, St. Lucie Count\