HomeMy WebLinkAboutTrussez—
19-4'
Products
PlotlD
Net Qty
Product
Length
Plies
J1
9
16" BCI04500s-1.8
18' 0"
1
J2
3
16" BCI® 4500s-1.8
16' 0"
1
J3
10
16" BCI® 4500s-1.8
16' 0"
1
J4
1
16" BCIO 4500s-1.8
16' 0"
1
J5
1
16" BCI® 4500s-1.8
16' 0"
1
J6
3
16" BCIO 4500s-1.8
4' 0"
1
J7
10
16" BCI@ 6000s-1.8
21' 0"
1
J8
1
16" BCIO 6000s-1.8
20' 0"
1
J9
4
16" BCI® 6000s-1.8
20' 0"
1
BM1
2
1-3/4" x 16" VERSA -LAM® 2.0 3100 SP
20' 1 1/8"
2
Bk1
18
16" BCI® 4500s-1.8
2' 0"
1
Bk2
4
16" BCI® 4500s-1.8
1101,
1
Connector Summary
PlotlD
Qty
Manuf Product Skew Slope
Hut
24
Simpson ITS1.81/16 - -
Hu2
15
Simpson ITS2.37/16 - -
Hu3
16
Simpson IUS1.81/16 - -
ran tuDue h'RbaW®S M L. 31llmMla6
IIffORC sec7rw O NRRD 10 lmtAss
t
-- 21'-e le-0'
PA. Gl-e Avi d—w4 ol-u
Totat Truss OumtRy . 107.
THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND ARCHITECTURALS SUPERCEDE THIS DOCUMENT.
PLL
. .. CONNECTION.I
o �
I
r
u
TYPICAL 7' SETBACK
CORNERSET LABELING
AND SPACING
DESCRIPTION INIT. DATE
=x
Imum
111r
lam
VIdAWMR Ins Llaa M
Vp/a
6II
am Lau
am
NYa
Faa
DC tau
.w,
4Na
wa
NZ UM
Lm
Ialtr/a
Im
Na troll
m
enam
Im
LD
lam
rL5[ LnD
D1!
ddB
Il.al
K¢ ram
m
uv
LOAD# DESCRIPTION INIT. DATE
d
or oa. IMI L:C tar
erma
oN
as aama as
twain
m
IiV.Itf= .RI
er"
m
ICVi! aM61a1 M M LD
r41e/ID
Oc-
Z O ti vfi r LD
a am
m
Rcm r.121Der a m LD
9AM
a
Ipl® anma W
a/D/m
ev
rtr� to
unim
�m IwD:tmmtvaatsa rrnl rasa®�
HANGER CHART
d6= HUS 26 (SIWSON)
A \. HUS26-2 (SIMPSON)
l.".d Ed Yak
General Notes
1) All0 pawl dvd 4i. flat fnw ad Got
he kmtdW W e h tp6 Potiled tom
A hap= to be Sing m RM6 mlm aft�M
2) notd.
3) � wxi,p (a 2V D.C. whn otl�tea
4) panam, XHatshmdig ihoM plaW ut a
nwi= epad,q 15' QC a Poe wm4 to
bs ,heated at a mmtmm of 2W baNaen each
X-Non ftm*aA 6a Lhuchm
Plane rttfe to 8C -81 for aV odd5ad Nang
delah.
ROOF LOADING SCHEDULE
TCLL = 20 PSF
TCDL = 7 PSF
BCLL = • PSF
BCDL = 10 PSF
TOTAL = 8.2 PSF
DURATION = 1.25 %
WIND SPD/TYPI= ISO
ENCLOSED
BLDG EXPOSURE = C
USAGE = RESIDENTIAL CAT II
WIND IMPORTANCE FACTOR= 1
UPLIFTS BASED ON= 9.2 PSF
DESIGN CRITERIA
FBC 2020
TPI 2014
'boss membn design & connector plates
e dcsi ed for ASCE7-16 and tm im
forces from both components and claddings
and main wind force resisting systems.
• These trusses have been reviewed m carry
additional 10# psfnon-con t bottom chord Svc
load.
LFORADING SCHEDU
= 40 PSF
= 10 PSF
= 5 PSF
= 58 PSF
ROOF DESIGNED FOR
SHINGLE
ALL REACTIONS OVER 50DOI
AND UPLIFTS OVER 1000E
ARE SHOWN ON ENGINEERING.
WALL KEY
08'-8" MEM
®18'-1'1
LOAD DESCRIPTION IN1T. DATE
Im mm m u/m/m
aY 11S LaLI LD e/LIm
LOAD/ DESCRIPTION INrr. DATE
W
laanm LD
7/MM
tR
um LID
Ui
a
Rvrrrt Iss LD
M44M
uh
Teo to LDaa m
eimm
NER-CARPENTER
CONTRACTORS
OF AMERICA
3900 AVENUE G. N. V.
WINTER HAVEN FLITRIDA 33880
PHONE-<800) 959-8606
FAXI <80) 294-2488
BUILDER DR HORTON—BIWARD
PROJECTCREEKRIDE
MODEL 4EHB/ HAYDEN/ H
CCA PROJ/MODEL/ALT
7A5/320/4EHBH/01
ALT DESC 10' X 8' COV. LAN.
OTC 3349 TRINITY CDR
k.LOT 83 BLOCK
DESIGNER
PAGE
RAA
1
1
ATE
10##24 17OLAN
N362326L
3ALE 6 "=1'
•c _
ALP E
March f-3,-20.19 m UWCM'* IPM4,
Mir. Bob. Michaelis
Car'. 'ht r-00.6tr6dtWs OfAmdriba,inic'..
e P
,390QAveijue 0.... Norihwest.
Winter HaFveh,.:'FL 33880-6201
Re: Alternative fttd1lations.-for 6 single 01y carried truss with a width less than the hanger width, ,and .
wbod.blodki g lq achieve fUll design -for fo'ce-mounted.bgrigeraft -hiont -a,oh#ply�
loqd'valluo. .a6h on
.supporting girder (Rbf&6rr66 Mail WMM2)..
Dear Bob,
Fora single ply carried truss with 'a width less than the hanger. Width you'" can.ihstalf:a. prefabricated jack.
scab truss: (?11) fQr woodfiller bl6ckiogi: The, chord : sites- -'qhqrd..gTa0es, and ApirTo!o6nnect6r.plate(s) to
y The prefabricated s ve.a.minimurn be the. same at ffie sirigle'.0'".carried tr.'Uss.' cat6d.j k1!!§dab'tr" ha'
minimum pit6h.:of 5112, The single ply carried - tv.psg
length of 481' and will have a M.!ni M. shall have: a. reaction of
3,.500.# or less. Attach 'prefabricated. jack:8cab: truss. witlI two. of 0.1 28.nx3 ff" GUn Nails at'2'
P16as6-t6f6r16the Simpson trong S" -Tie..Catal 2010,.ppqq 216. Figgre:3 for more information,
Figurie.."I
For -a single- ply".-glM erthat requires wood blocking to,adhibive:�fUll design load valuefor face -mounted
hangers -attach one wood. block 19 'the back face of ffie. single :ply g�r.dqr with the: same site and
Q. with
grade..as the bottom.- chord.Of the. single ply girdbr. The: o6d: block length to lie such that."the -w6cid
blocking ,e)�teqq§to earl j� adj.acentpah6l Ooihts �(Webs'-Afid bottom.
chord intersections),:, Attach wood
b O*CK: C)"Wit. x3. 0" 6 -0- O.-C.. per, ow,.staggefad 3.0" applied to the l h wa-P) rows.-46.1 -2 G4n N'Jils dt. r
676o Forum Dflive 8uite 305, b.rland.q, FL 32821 = (OQO) 62-1-970.6 ''(85.3):422-8685
-.www.alpinei w.,00m
pw
.AN.
awcomw
single ply-girderf6c% With an additional (20) O..l.�28'.lx3',.O"'Gun *:Nails at--each-pane'.1.point applied lo'the,
wood . blodk.fabe(S6e Figori3'2 b-e,li3.*.)..Ple.as6refer tothO.�SimOsdh$trohg�T.ie:C6t'a'lbg Cre-20193
-page 216, flo.Ur.01'for moreinformation.
Figure Z:,
. ......... ......... ... .... ... . ......... .. .. .. .. ...... ...... ... .. ... ... .. .. .. . ........ ............ ............ . .... .. ... ......... .. ... ......... ... .. .. . . ........ ... .... .. ... . ... ........... ..............
The -application of prefabricated jack 'scab truss forwoodfilldr'blockin.'g :or Wood :bJockipg to.: pph.jqv.e. fUll.
u
design load value for face; -mounted hangers, must be -approved by the. hardware. rnpnufa .00rer..-
At! edge and end: distances, and. spacing 'for . ali nail connections must be su . ffidi6ntto preventsplitting of
"Wood.,
if I can. be. of any further.assistance,.o.r if. you have any: q uestion.si pleasqgiye-meacall..
Nio.10861: I
STATE. (IF'
William K Krick P.E.. V,
Chief Engineer
Alpin*e.a 11-w Coni,r)
n any elf,
Engineering POpqrtment
OHandoi FL
6750T61rium- - NV& SORO'306,0flan' d6,. FL .32821 - (400)521 -9790 - (.863) 422-8685
April 26,':2019-
Mr. Bob Michaelis
Carpenter Cobtradtors ofAtneridA, Ind.
$9.00 Avenue Q, Northwest
wiritet Haven, FL 338 8 0-6201
Dea.r. Bob,.
.R(§* Strok ba'ck bridging 6n'fb6f trusses.
I understand -thete is -sorhe concern over our recommendations f6r.strdhgback- bridging on roof trusses;
StrongoAck bridging - for roof trusses is not a:requirpment of:AN S.kTPI 2014 nor is:!.are qWrementofthe.
Building Component -Safety information- .(BC.SI):. But strongback bridging, orf roof - :trusses it
s
by C4rpphht&.Coht -.6f. menca: -St6hgba6k brj�O�Ihg,: UP$ .9
:..-._recommended.e -the follovvin Wo.
functions;
One, bridging aligns the bottom -qh_o..r...d..s �.after..-they: are. set so.. they are uniform along the ceiling
fine and h
'
T.woi bridging reduces relative deflection i6h of. adjab6ht:tirUssdg:
Strongback bfidging.does riot: prevent or reduce -overall individual cleflectian, espedially ariy r66f trLi§s6s,
than inch.
...............deflect (pg 14 ...... . ...... ....... ............ ... ....... .. .. .
Strongback. bridging in roof. trusses doe's not serve* as teml5br 6 ry . or Pcifta'66ht: bracing % and is, not
i . hton,ded* to' dis'-trbute. or share design' loads. between trusses. Consequently, , no dp.sido load* have:
'
.been accounted for'With this. detail and continuous: Wdhgbac k'bHdg1hg should ' not :be :attached between
cofnrhon and :girder
i -trusses- - The use :of strongbaqK bridging shall not. `interfere with other- design
;.r.der
considerations detati6hs as. specified . by. the Enghebrof Record or the. Building: Design,6r.
The outer ends of the bridging shall be attached. -to a
wall or anothorsecure end. resira,int'. of
ap..sppcified:.Py the 5rigiheeir- of Rbbord or.the Buildina.136sidindr.
Strongback bridging shall. be -'a minimum Of 2X6.nominal lUrnb6t ofidht6cl -Mith the depth Attach
with 8) 16.d :common nails '(0. 1167"x&: 9 nails at;. each intersecting When extending the-
h 'do
:strdngback bridging overlap by at. a.minimpm -qf..two fr.ussps. The location of. f. � e�-. strQngback bridging
irig'.
P Y fa 9
maybe spedifiecib the-TrUis Manufacturer,: Ehgirie& of R6dord, or Building Designer: e
BGS! "Strangbacking Provisions" or tP..Al in*- STRgRIOR1.014 detail for more information
The, graphic
.§hoWh (Figure- 1) is for. -generic IlluWAtivi 'pUrposeonly.
67.0. F.6ru!n Drive:S I uite 305, QMndo, FL 3282-11- (800) 521_97K -.(863)42M685
'vhv—wIWPin&itvV.jtom.
ALPINE
0'.]L5 -Not
Fllgwel,
If I. - can . be of any further assistance' orif you have .any questions; please -give. me a call.
WiIIia&l.H.,Knck-10_'E.
PhiefEng-k9ee ' r
Alpine an !IW..Co.mpany
Engineering' Depait me'n"t
Orlando;. FL 3282.1.
Forum Drive Sbite.-365, Orlandd, FL 32821 -; (800) 521-9.790 - (853)-.4224685'
STRONG -BACK: .BRIDGING RECOMMENDATIONS
BUTT §TRBNGBACKGETHEq 1'
is All sc6b7 -.on blocks shall bz.-cx.minimum. 2x4
'
BRIDGING TO
'stress gradedgradedLumlumber;'
M-AL..s-trongback bridging .and bracing s . h&L . ( :be :a.
mIMImurq x sgraded,- .lumber;'
4
0►Thepyrpose of 5-troM�briclha.ls, to
6
ATTACH SCAB WITH*l0d;Blx�GUN..
i
Ceveiop Aomcsharing n:lnrlvIdUbA trusses,,
; 4! -V Zx6-MIPEN=). WAILS IN-2 ROWSAT'
D.C.
rest. In -dn 'b�4ral.( lhcr&a!Eie- jn'-,jh
.,SCAB' ..6,
NOTE, :IN LIEU.VF- SPLICING. AS'SHOWN,
•
stiffness' of he. floor system,
LAP"STRONGBACK-1RIAGING MEMBERS-
Fak-:AT'LEAST ONE TRUSS
str.-ongback. b)�Idglng, pdkl�tlohdd as.. �s�.hawi ' In
n
STREINGBA.CK'BRIDGING: ':SPLICE 'DETAIL
cletalls, Is recommended .at 10' "C', o.c. (MCLXI>
J`
om--Tho- -.terms.- -and 'bracing` are. some -times
NOTD Details j and R.-arlL, the :pl''ef.er6?d' 6ttatkmen't Meithods.
ATTACH STRdNdAck TO
WEB V/ W 10d.- C13WHON
mlstakenkyusecl.-"Int"eychongeab(j..'* 'Tr.adih :an
impqrton**t structurod requlrem'ent- bf floor
NAILS
:any'
t.
Tru
51g
(T D) TOO. "the,brgdnb r" ulr.'0m.e is 'for
n
I each n g.
-6c. ... dlVldIQ0LL ...truss component. 'Brldgln
I
particularly' `stronQbqdk-'l.brIdg!r)g' Is. a:..
rec6mmphdation- for a -tr.9- :5�yto. help
astejm
con- . vI bratloft In: :dlho..'In the:
tr.P . addition. -to I
distribution of point' loads betw4tih adjacent'
s .0 t6
�t.r ngback bridging,serves � reduce
(a)
STRONGBACK BRIDGING. ,
SPACING' REQUIREMENTS
W . io MY Nbnw r6aubed
kun� g ut. mg: from
moving point Ibadtj%:such as foc)-tst.ops
IV io.,2V I-rvo:(At curkr of vW
The Pierf ormanc'e. of OLLL floor systems -are
3kMMM 8!
.xa0l) OR
*
MlesliclV) �NAILS AT 2x6 IGBACG -
(MINIMUM) STRON - BA K
W,;; 40
enhanced by. the. IntA 'lah of ..t
atliat strop atk.
.1 . I
-A2...k MM.:UF 2x4 RESTRAINED EAcH.END. '
5;i-r _4V M V)hc *&�
i2mr, Malp,
. bric . [gin and -therefore . U. strongly recommended
tTR
AN ffWGDMPAW
12793 FlIvi*4 Odra
SM14 Ma
.XBMWN&,M06304]-
lay Alpine,
(A
k8l.
For additional lr)fdfmo:tIoh -,.5trQngbaqk
refer bridging, t.�,BCSI au'Roling Component
Safety Information).
ATTACH S7RONGIM!
M BOTTOM. Dom. WIN
kO
H
lAOk BRIDGING ATTACHMENT A .TNES w
VPJU":,TM MMLLEr.
V•C0WVVLl=
LL: PSP
REF -STRONGB AQK
No. 70861.
TAX PSF.
ATE
-b -W.0/14
all
lip SIDL PSF-
PRYG jSTRBRIBR1014.-
-LL PSF
8 T-I�TF, - F
PSF
Mau
ii7' sbl!ftM.'psR�k' .
t'^
No MOO
TFa�rr pp����yy}}' �l�1��•:rtr�{�rig z � � r�' air Q . erg s s,. SH00r«a
. � i�f� ATE�1 ���� 17�i�'. �i�`:laf�E?�F�:.�. 00'., I# 101��i#Cd�!"'it�l�l �f►��'irFf3l�L .-
I� 'C�'N
AT L .A,—%.T �W TRUSS: S..-
. etc I SM� -APPROPHTA : ,P .` I ANN. :.LlMBR 'L ? 5 AND.:
WHE'S DATA
3ut#'d.iue:M--o:t14 &l.
���-�:4tl'it,�'}��� �:�Y �sf;! ���,:. jA,�!;�',4� �'. .'�iEi'if�i��!ti�••.� ': r�F: ��� 2p���.�1��
0k 37ftk''1`DA.: f�f
o.ry icltR .sf r1"�nyer, '`T
�) 5
pp". {�''!�' (f�l'}�� (' Fjy� .. ,y{��,�'y' ... - •�M"�-i• .L-00 Ri�n, • -- 685 M1 F •�" l y' - ,w , Yi.*T `�M1 1A.•: I ro
r
I
: .>.. , :,. .�. -. .v��•x c,3r;.n„+...,..rle..�i,.ornRl,....,. a�� -�..r;:,r::ir;�r::»r=' .I—i-�:n� `',-+- _ '•;I•r-:,'M-.�;.ac::••,I•-. -- - - - - - ....y.,..a•:;....,.:.,� . ,
I..
,
,
. kti
y,� �j fir, tl' •`` i;; I •
I J < '
w:l
Is
r
:
E. NONS
lxaz
- ty:,l .'Y.=i C_^_o . ice- d .,F�' � '• .. � r •���i .: i�: •�»��i'�-�.._;. � . LI'•
E�7 Cap
30.7-4
Ml
r\N
.. xFL�'8
E � i
Cracked or Broken
This drawing specifies repairs for a truss with broken chord
or web member,
This design Is vaLM only for single ply trusses with 2x4 or
2x6 broken members. No more than one break per chord panel
and no more than two breaks per truss are allowed.
Contact the truss manufacturer for any repairs that do not
comply with this de -tall,
(B) = Damaged area, 12' max length of damaged section
(L) = Minimum nalling distance on each side of damaged area (B)
(S) = Two 2x4 or two 2x6 side members, some size, grade, and
species as damaged member, Applyy one scab per face,
Minimum side member length(s) = (2)(L) + (B)
Scab member length (S) must be within the broken panel,
Nall Into 2x4 members using two (2) rows at 4' o,c., rows staggered,
Nall Into 2x6 members using three (3) rows at 4' oz., rows staggered,
Nall using 10d box or gun nails (0,128'0', min) Into ear-h side member,
The maximum permitted lumber grade for -use with this
de -tall Is limited to Visual grade #1 and MSR grade 1650f.
This repair detall may be used for broken connector plate at
mid -panel splices.
This repair detail may not be used for damaged chord or web
sections occurring within the connector plate area.
Broken chord may not support any tie -In loads,
S•
L 111110. L
�Typico.
+ o + o + o' + o
0 + 0 + o + o +
Ste
agger
+ = Back Face 10d Box (0.128' x 3', min> Nallsi
0 = Front Face 2x4 Member - Doubble Row Staggered
2x6 Member - Triple Row Staqpered
Nail Spacing Detail
Member- Repair Detail
Load Duratlon = 0%
Member forces May be Increased for Duration of Load
Maximum Member Axial Force .
Memloeri
Size
L
SPF-C
HF
DF-L
SYP
Web Only '
2x4
12'
620#
635#
730#
B004
Web Only
2x4
18'
975#
1055#
1295#
1415#
Web or Chord
2x4
24 f
975#
10551t
1495#
1745#
Web or Cord
2X6
1465#
1585#
2245#
2620#
Web or Chord
2x4
30'
1910#
1960#
2315#
2555#
Web or Chord
2x6
2230#
2365#
3125#
3575#
Web or Chord
2x4
36,
2470#
2530#
2930#
3210#
Web or Chord
2x6
3535#
3635#
4295#
4745#
Web or Chord
2x4
42
2975#
3045#
3505#
3835#
Web a Chord
2x6
43950
4500#
52254
5725#
Web or Chord
2x4
Be .
3460#
3540#
4070#
4445#
Web or Chord
2x6
5165#
5280#
6095#
6660#
NlNnun a L
L Dlstwee
Minimal
L Db:tnner
8
"VARMN011s READ AHD MUM ALL HGTU ON THIS WAVI1401
WWORTAHTss FURNISH TICS TRAVM Ta ALL COW111470RS INCLISING YK MTAILGRS,
REF MEMBER REPAIR
DAT� 10�01�14
,.
Q ��
7russrs require ewtrtne cart h fakelcathlg, hw%Mlra, shpPk�o metal and bradn0. Refer to and
follow the laisst edHlan of hest ®Lading Comfwwnt S¢fety in(ornotlon, by 7p1 and SDCN far s¢erty
Vic prior io perfatrnbli those functlons. installers sh¢11 provrle tsnpororyy �bractn per 7CS1.
unln¢ need otherebu, Lcco chard � shall have property attached structural shemA end hattan eltard
shall have a properly attacked aCS erllno. Lamtlons shown for pernonent lateral restraint of webs
eFNIt hove bracing Metalled per 1 se 13, a7 or atD, as applicable, Apply p�'� to each face
of truss end "Van as shorn above end on tine J¢Ini artalt, wllrss note aiherwise,
Refer, to drawNpi faaM2 I¢r standerd plat. polltlons,
_
DRWG REPCHRD1014
AN RW ODMPI�HY
IaaeDLakeAromOdva
Eadhalty,M0e3045
Alpht, a dNialon of ITV ILA tlln Components Dre Inc, shall not be responsible for r drvl0lan iron
tNs drawing, any faAurr to j;J J` he truss In canfornance with ANSI/Trt 1, r for hand 0 shIppho,
tntallmilon O •hbrracMp of trustee
A Sr¢l'm ilda ernrhp or cover pope listing iNs draskg. Indcates acceptance of professbnaL
erphrerMo rrganslhiNYy, solely for i f! t Iselyann shown. Thr adWbuty ¢nd use of iNs ddrarM+O
fr any tUre Is ills rnpahsLAky oP the AJkMq Des 1 per AHSwrl t Sect
For non Infarnnilon set thle.,Iob's general notes Ppeppe and tinter rrb sltesl
ALPINO sw,el neltw,eenl TPL we,tplrrt,orgi SDGr rww�sbelnductrya V, 1CG rwdacsafe,org
,
,
'
SPACING 24,0' MAX
e
0
R)Cfd.E
BOARD
WO
Lumber size and drade-Minumam Requimmignts
R .ak6 --b- -Z�xr-.W4 ! ctm; .m�.;s#comm Pid-t-Out-,
..r T
Sleepers
fat -W
16
w III it *s6vaty-spiewde beih
PQM4 * .
.OqLLARSEAK.EVERY 7WRQ,
PAIR,OF RAFTERS
P
-MOSPA-IGING 44)"
Of Valley kro IbAL
a
P
TYPICAL 40MMID 2�e4 rfln-24" 0.
;SPA itio 24-Ab.. MS -2x4- at. KINA .(Yiiwrq no. h a. 169. ap I
a
Ok LOVROO-V
PLA N-
rafter If
t2knpa wheds):.4qW-w 14M§ lCurgrtJuss -'hd' r a-etl#+ '11
�M7&jWfi-yalley WOW ill-'b' 4P19 all 'Aallothp I
-Max[Mu(n rfik).A 'rdb'f height; 30-1veL
14p mphI.En4osed, Cat I
TRUISS-
'
ER VALLEY FRAMING
VALLEY RAF1 EIR-OR RIDGE
+qrfpoleb,-41-M1*1dr-30 PSf (TL)'Itnd -26 POf (TID).Mak.
nawcrk(hv. td . JR
-i.
-urniffiriiiO.A40
4 ails
C-iTvP1& 16 f laii.
3.
CrIp"
sheathing
4.
. . .
bjb4kIhk
516ciltoo
Mftdyt&%WOL2X6 sleepers.
426dtoe-dalfi
S.
-Ste-ape td-tr.tvi-
4*16dtd&ftll5
T.Wd*.-bITsl4d06e,Xh:fKj St
3160 tdd-1.rjjUs.
,ea.ch sleepe
.6.
Aidge1ohrdic roof bldck
415dtoe-nSlils
'REGMFOR PnV�i
-y
.-R-,d'S"e-16.2fed fojr.Wes-
436d-tdtA,4JJIs
S.
.-Fruffiri to (Typl,
3;16.416a-nofjs.
.g.
Trizi..t0:6 I bo4kme
416it.tocrA511$
10.
Truzs-td;krlophi.
416kf-toVrraif5
rrusq,to du�.Ip-
4-1G.a.tOe7Wl1;
:AREUSED)
-13.
Cbll4opeam ki3--YaftdO
4 16d*toe-nalls.
NOTE f.1aiOAG2N9.S-y COMMbff
NAHA
T L� ;9.6'-30 46 54 9t, r NktLf-'Y Vd,'
WWMMO� W-6 90; F6=0 Al "=I
-MUM,
rUF4=;TF= WAMIC V d wjo-Rt. 64
S$W, . . 0 * TC DL- It ZO 7 '? DAT9 !O/PI/1'4
for_- irt
-f4 ory , m,
, , ,
praclrui,. prior: id t6- DA w
-.4ww ., 0 .0 0 0 DRW.G V q
-4�N f
T, 9', OF
I INVI80101S
ur��sz rat
...,w eut: -i&; TA
ww. b. -ti,6 J-ih Wo,
laaq
E.S."r.....M., 4 A N,
=1 41.4 :-w = . %1 - , lt� BC- LI, 0 .0 0 0
60.� 'plate W - . �N
a, dvls7on of -.4, ot ro — .2Yo'h,ad'+tt'tritYr'heenfarhance'ektl'nit5t/T�t.L or fa. d % r-1 -7 61
OR 1-9 TOT. LD..5'0 50 4 -
m uw C &4PAW cau
WOO"
srtaCon ..Of
f PoroAm %w W NN
0�,- rA;,- ABOVE
i iNx.J;b'% mwb. , I : . I . .
-W.
#LPZZ-wwwAh*wktk;;v.� k�� X=O "M
•
Face -Mount Hangers - I -Joists, Glularn and SCL
........... .......... I ........................................ . ............ ......... . .......... . .... I ............................................ ........................ ............................................................ ........... - .................................. . . . ................... . ...... . . . ........... . . . ..... . ...... . .. ... . . ....................... . .................... . -
[D These products are available with additional corrosion protection. For more information, see p. 15. Codes: See p. 12 for Code Reference Key Chart.
A
M
EM
Carried
-Dimensions
F' asteners
Allowable Loads
!
Member
(in;), .
0
A c '
bFISP
�Joist
Wodel
MW
Cod6
S lze.
NO
Web
Max
ea er
Species H" d
S POPI. r,
Ref.
StiffB
Rqd,
*'
,,� H
Face
joist
Uplift
Floor
'(100)
Snow:,,
Roof
Floor.
Snow,
RooV
Jim
'(115
5(160)
Y
15)f(1251
Min.
(14) 0.148 x 3
70
1,660
1,805
1,805
1,425
1
IUS2.56/16
2%
16
2
Max.
(16) 0.148 x 3
-
7
.0
1,805
i'8_105
1,P
:. 05
1 11,555
1,555
1,555
21/2 x 16
MIL12.56/16
29A6
157/16
21/2
-
(24) 0.162 x 31/2.
(2) 0.148 x 11/2
230
3,455
3,920
4,045
12,970
3,370
3,480
U314
• V
29AG
101/2
2
-
(16) 0.162 x 31/2"
(6) 0.148 x 11/2"
970
1,945
2,205
2,37511,675
11,895
2,045
HU316 / HUC316
V
29AB
141/8
21h
-
(20) 0.162 x 31/2
(8) 0.148 x 11/2
.1,515
2,975
3,360
31610
1 2,565
2,895
3,110
IBC,
FL,
0 .
MILUZ.�64'
-1, 3(
2;
(�6) 0.162 x,3W
(2) 0.148 x 11/2
74 5
4704 5
��04 "I �
I
f, �
LA
,2-Yk 18
'HU316 /,HUC3,16
12"As'
2 M2
01 62x3!W'
0)",
`,(8),OA48X1 Id"'
-1515
2,975
3,36013'610
25
21/2 x 20
MIL12.56/20
12�/,.
191/,6
21/2
(28) 0.162 x 31h
(2) 0.148 x 11/2
1 230
4,030
14,06014,060
13,465
13,495
3,495
21A6 x 91/4
to 26
29AB" wide joists use the same hangers as 21/2" wide joists and have the same loads.
MIU312/91
9 146:
X
x
HU -2 / HQC21 _Z_1
. 910 I Pl-✓
'A*�
I
-
"
" Max�X.
0 X
48 x 3
55,
2,680
3,0201
1
1BG'
MIL13.12/11
131/.!
111A
21h
_20)
0.162 x 31h
(2) 0.148 x 11/2
230
2,880
3,135
3,135
2,475
1 2,695
12,695
FL,
gX 11 7/S
111.12'12wZTHUG212-2
+.•1
✓
1 31/al
109A6
21/2
Max:�_
- (2 2) 0 16 2 x 31/2
(10) 0.148 x 3
1,795-3-275
3,6951
aXO-
-2;820-1-3,180
3,425
1
LA
FL
1BG'
FL
1 31/2 x 51/4 IHHUS46 1- 1-1 1 - 13% 1 51A 13 1 - 1 (14) 0.162 x 31/2 1 (6) 0.162 x 31/2 11,32012,785 13,155 13,40512,395 1 2,715 ",930
IHGUS46 1- 1-1 1 - 131/.1 47/t. 1 4 1 - 1 (20) 0.162 x 31/2 1 (8) 0.162 x 31/2 12,155 14,360 14,885 15,23013,750 14,200 14,500 1
711"A".
rlr1UO!io
T I
'I
�_,178'1
4 ZB'
1,
ftIVIVI
Oq t4v
I 01y"11)
J'xt'vvy
1111, "i
�HdUS48"
3%f
7M�
4 "J,
I (W)OA201/
'(12)0.162X31��
�3,"�3&
7,466
7A d
Z4601
6,415
6,415,
k415
IUS3.56/9.5
35/81
91h
2
(10) 0.148 x 3
-
70
1,185
1,345
1,455
1,020
1,160
1,250
MIL13.56/9
.
3%,
89A.
21h
(16) 0.162 x 31h
(2) 0.148 x 11/2
210
12,305
2,615
2,820
1,980
2,245
2,425
U410
.
V
39A61
8-'A
2
(14) 0.162 x 31/2
(6) 0.148 x 3
970
12,015
2,28512,465
1,735
1,9651
2,120
HUS410
-
-
39A61
811A6
2
(8) 0.162 x 31/2
(8) 0.162 x 31/2
2,990
2,125
2,420
2,615
1,820
2,070
2,240
HHUS410
0
-
3%
i 9
3
(30) 0.162 x 31h
(10) 0.162 x 31/2
3,565
5,635
6,380
BA45
4,845
5,486
5,545
31/2 x 91/2
HU410/HUC410
. .
. I V
139A.
85A
21h
I -
1 (36) 0162 x 31/2
(12) 0.162 x 31/2
3,235
7,460
7,460
7,460
6,415
6,415
6,415
HUC0410-SDS
. .
-
39AB
9
3
-
(12) 1/4" x 21/2" SDS
(6) 1/4" x 21/2" SDS
2,265
4,500
4,500
/L506
3,240
3,240
3,240
HGUS410
0 0
-
3%
9 'A 6
4
(46) 0.162 x 31/2
(16) 0.162 x 31/2
-4,095
9,100
9,100
9,100
7,825
17,825
7,825
FL,
LGU3.63-SDS
. .
-
3%
8 to 30
41/2
-
(16) 1/4" x 21/2" SDS
(12) 'A" x 21/2" SDS
15,55516,720
6,720
6,720
4,840
4,840
4,840
LA
MGU3.63-SDS
. *
-
3%
91/4 to 30
41h
-
(24)1/4" x 21/2" SDS
(16) 1/4" X 21/2" SDS
7,260
19,450
9,450
9,450
6,805
6,805
6,805
11US156/11;88 1,'�
2
x
70, 1149
1615 1174511
.22
" 0;1
1.340fl485
' I
.46
See footnotes on p. 150.
THA/THAC
Adjustable Truss Hangers
This product is preferable to similar connectors because
of (a) easier installation, (b) higher loads, (c) lower installed
cost, or a combination of these features.
The THA series have extra long straps that can be field -formed to
give height adjustability and top -flange hanger convenience. THA
hangers can be installed as top -flange or face -mount hangers.
THA4x and THA2x-2 models feature a dense nail pattern in the
straps, which provides more installation options and allows for
easy top -flange installation.
Material: See table
Finish: Galvanized. Some products available in ZMAX® coating.
See Corrosion Information, pp.13-15.
Installation:
• Use all specified fasteners; see General Notes.
The following installation methods may be used:
• Top -Flange Installation — The straps must be field formed
over the header — see table for minimum top -flange requirements.
Install top and face nails according to the table. Top nails shall
not be within 1/4° from the edge of the top -flange members. For
the THA29; nails used -for -joist --attachment must be driven at an
angle so that they penetrate through the corner of the joist and
into the header. For all other top -flange installations, straighten
the double -shear nailing tabs and install the nails straight into
the joist.
• Face -Mount (Min.) Installation — Install face nails according
to the table, with at least half of the required fasteners in the top
half of the header. Not all nail holes in the straps will be filled.
Nails must have a minimum 1/2" edge distance. Straighten the
double -shear nailing tabs and install the joist nails straight into
the joist. The face -mount (min.) installation option accommodates
conditions where the supported member hangs either partially or
entirety below the header.
• Face -Mount (Max.) Installation — Install face nails according to
the table. Not all nail holes in the straps will be filled except for the
following models: THA29, THA213, THA218 and THA413. For all
other models with more nail holes than required, the straps may be
installed straight or wrapped over the header, with the tabulated
quantity of face nails installed into the face and top of the header.
The lowest four face holes must be filled. Nails used for the joist
attachment must be driven at an angle so that they penetrate
through the corner of the joist into the header.
• Uplift — Lowest face nails must be filled to achieve uplift loads.
Options:
• THA hangers available with the header flanges turned in for
35/e" (except THA413) and larger, with no load reduction —
order THAC hanger.
Codes: See p.12 for Code Reference Key Chart
for
,422
for
122-2
126-2
UIN'THAC422
Face nails Top nails
pertable per table
13/4' typical
21h' for THA422-2
and THA426-2
THA418
2� 1/ayl
8ffi °
'affi
hw 21t1
THA29
Double 4x2 — 2 face nails
Use full table value (total)
Straighten the double
shear nailing tabs and install
nails straight into the joist
Typical THA Top Flange
Installation on a Nailer
(except THA29)
THA422 Face -Mount
(Max.) Installation
Straps may be installed straight
or wrapped over with tabulated
face nails installed into top
and face of headE
® Double -Shear
Double Nailing Dome Double -Shear
Shear Side View; Nailing Side View
Naiing Do not CC
(Available on
Top View bend tab some models)
Single
S1
nailer
Straighten the
double shear nailing tabs
and install nails straight
Typical THA422
Top Flange Installation
on a 4x2 Floor Truss
THA44 Face -Mount
(Min.) Installation
�er to
tnote 5
p.187
86
Top Flange Installation
U
z
a
0
0
U
0
z
0
Cn
z
0
rn
0
N
0
rn
0
N
U
U
THA/THAC
Adjustable Truss Hangers (cont.)
These products are available with additional corrosion protection. For more information, see p.15.
0
1.,ffikle
$,
ads
THA29 18 15/s 9"fi6 5'/e 11/z - (2)0.148x3 (6)0.148x3 (4)0.148x3 1 525 1,750 1,750 1,750 1 450 1,3301,330 1,330
27/s - (4)0.148x3 (6)0.148x3 (4)0.148x3 1 525 2,61,32,610 2,610 1 450 1,985 1,985 1,985
THA218
18
1 %
17-i6
51/z 1
2
-
(4) 0.148 x 3
(2) 0.148 x 3
(4) 0.148 x 1'/z
-
1,460
1:460
1,460
-
1,110
i 110
1 10
IBC,
,ThtA218 2
16
.3
17�1s
,
(60148x3"
19c
D
4D0J6>!z
FL,
.
LA
THA222-2
16
31/a
22'6
8
2
-
(4) 0.162 x 31h
(2) 0.162 x 31/z
(6) 0.148 x 3
-
1,960
1:995
1,995
-
t;49U
1,515
1,515
`THA413
18
35/e.
13V's
"4'/z `
2 �
- _
. (4) Q 148 x &"
;; (2) 0148 x 3 "x
--77777
" (4j 014$ x 3
1 3t
THA418
16
3%
171/z
77/a
2
-
(4) 0.162 x 31/2
(2) 0.162 x 31/z
(6) 0.148 x 3
-
1,960
1;995
1,995
-
1,49U
1,515
1;515
THA426 114 1 35/s 1 26 1 77A 1 2 1 - 1(4) 0.162 x 3'/z1 (4) 0.162 x 3'/z 1(6) 0.162 x 3'h1 - 12,43512,4351 2,435 1 - 12,09512,0951 2,095
FL I
THA426-2 114 171/4 126'161 93/4 1 2 I - 1(4) 0.162 x 31/z1 (4) 0.162 x 31/z 1(6) 0.162 x 31/z( - 13,330 13,330 1 3,330 1 - 12,865 12,865 1 2,865
THA29
18
- i s/s
P/,s
51A
1
91M6
1
(16) 0.148 x 3
(4) 0.148 x 3
525
2,265
2,265
2,265
450
1950
11950
1950
T"HA213
.18 "
751a
13%['
� s
:5%,
13� s
(14} 0148`x 3
(4) 0;748 x•3'
355
" ts4 z
2 340
;!" 4 1.::
73u
=76
1t1,
210 „
THA218
18
1 %
17-34s
51/z
-
173A6
-
(18) 0.148 x 3
(4) 0.148 x 3
355
2,450
2,450
2,450
735
2105
2105
2105
THA218-2
`1;6
3'/a "17']tis
B'
14'fis
- ..
{22} O 162k(3'!z
{6)`0.162 x 3'fz
1, 855
,1�
a 31U
% � 31 t
1 595
2' 5
2,84`,
2,84ut ' '
IBC,
THA222-2
16
3'/a
22Y1s
8
-
14%
-
(22) 0.162 x 31/z
(6) 0.162 x 31h
1,855
3:310
3310
3,310
1,595
2,845
2,845
2,845
FL,
LA
TtiA413
-; 8
35/s
13'%
".4'/z '':
133/s
(4) 0.148 x 3
° (4) 0.148 x 3
55
"2 f
(3 t1
s 4 (J' '
fU
THA418
16
3%
171/z
77/a
-
14'/s
-
(22) 0.162 x 3'/z
(6) 0.162 x 3Yz
1,855
3;310
33101
3,31GI
1595
2;845
2,845
2,845
THA426 14 35/a 26 77/a - 16'/6 - (30) 0.162 x 31/z (6) 0.162 x 31/z 1,855 4,415 4,480 4,480- 1,595 3,795 3,855 3,855
THA422-2. 14. 71/' 22 '6ti 93/a 1S is (30) 016ZX 31/z (B) 0A62"x 3Jh 1 855 5;1.7Q 5,520` 5,52D 1,595 "4,445 4,745 4 745 FL
THA426-2 14 71/4 261/e 93/4 - 18 - (38) 0.162 x 31/z (6) 0.162 x 31/z 1,855 5,520 5,520 5,520 1,595 4,745 4,745 4,745
1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern.
2. Wind (160) is a download rating.
3.-Min. top flange refers to the minimum length of strap that must be field -formed over the header. The tabulated bads for the THA29 with 11h° min.
top flange are based on a single 2x carrying member; all other top -flange installation loads are based on a minimum 2-ply 2x carrying member.
For 4x2 truss carrying members with double top chords, use the specified fasteners for full tabulated values. For single 4x2 top chord or nailer
applications, refer to the Nailer Table.
4. Face -mount installation bads are based on a two-ply 2x carrying member minimum. For single 2x carrying members, use 0.148" x 11h" nails in
the carrying member and tabulated fasteners in the carried member, and use 0.80 of the table value for 18 gauge, and 0.68 of the table value for
16 gauge and 14 gauge.
5. For the THA 2x models, one strap may be installed vertically according to the face -mount nailing requirements and the other strap wrapped over
the truss chord according to the top -flange nailing requirements (see drawing on p. 186) and achieve full tabulated top -flange installation loads.
6. Refer to installation instructions regarding fastener installation into carried Ooist) member. Based on the installation condition, nails will be installed
either straight with straighted double -shear nailing tabs or slanted.
7. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information.
i
O
aa
V
d
C
C
O
V
N
N
7
N
M
d
-W
to
18
LUS/MUS/HUS/HHUS/HGUS
Face -Mount Joist Hangers
This product is preferable to similar connectors because
of a) easier installation, b) higher loads, c) lower
installed cost, or a combination of these features.
The double -shear hanger series, ranging from the light -capacity
LUS hangers to the highest -capacity HGUS hangers, feature
innovative double -shear nailing thw distributes the load through
tvdo points on each joist nail for greater strength. This allows for
fewer nails, faster installation and the use of all common nails for
the same connection.
For medium -load truss applications, the MUS offers a lower -cost
alternative and easier installation than the HUS or THA hangers,
while providing greater load capacity and bearing than the LUS.
Material: See tables on pp. 194-195
Finish: Galvanized. Some products available in stainless steel
or ZMAX® coating. See Corrosion Information, pp.13-15.
Installation:
• Use all specified fasteners; see General Notes.
• Nails must be driven at an angle through the joist or truss
into the header to achieve the table loads.
• Not desidned for welded or nailer applicafions.
Options:
• LUS and MUS hangers cannot be modified
• Concealed flanges are not available for HGUS and HHUS
• Other sizes available; consult your Simpson Strong -Tie
representative
Codes: See p.12 for Code Reference Key Chart
Double -Shear
Nailing
Top View
CCDouble -Shear Nailing
Side View
Do not bend tab
Double -Shear
QDome
Nailing Side View
(Available on
some models)
1' for 2,
1'tie"for 4xs
H
G�w B
LUS28
HHUS210-2
MUS28
b 6.
„, murw
HUS210
(HUS26, HUS28,
and HHUS similar)
951111-11
HGUS28-2
Typical HUS26
Installation
with Reduced
Heel Height
(multiple member
fastening
by Designer)
LUS/M US/H US/HHUS/HGUS
Face -Mount Joist Hangers (cont.)
Model
No
Min._a
He ght
Ga
Dimensions{rn:}
Fasteners
W
H g
Carrying Carried
Member ,j Member `
Single 2x Sizes
tUS24
Zsla
18 .'.
"'
1 1fi631/6
-
1 3/4{4)-Q1148
x 3- _
(2) 0148 x 3
tU826 ` �:
4✓4 ->
1 %i6`
A4 -:.
13/a „
" (4}.0148 x=3,
t (4) 0138 X 3'
MUS26
411/16
18
1'A6
53A6
2
(6) 0.148 x 3
(6) 0.148 x 3
HUS26
45A6
16
15/a
53/a
3
(14) 0.162 x 31/2
(6) 0.162 x 31/2
HGUS2fi -
06,` �.
12' '-
15/a
"" 5We
(20}.0162x31Ji-
'�`(8)0.162x3"h',
'LUS28 ,,
43A6'
1$,;;
1a/6
614
1Y4
(6)0.148x3:=°
` (4}'0.148x3 :
MUS28
6-5�6
18
19A6
613/16
2
(8) 0.148 x 3
(8) 0.148 x 3
HUS28
61/2
16
15/a
7
3
(22) 0.162 x 31/:
1 (8) 0.162 x 31h
HGUS28
69A6
12
1 %
71/8
5
(36) 0.162 x 31h
j (12) 0.162 x 31/2
LUS210 � -
F 41/4
18
1-' 6. -
773j6 ,g
1 /4 a
" '(8)'014&x 3,°-,
{4)'.0:14$ x 3"
'HUS210
83/3':
1fi"
15/a
9
3.-.(30)-0.162x31/2
(f0)^'0:J2X31/2'
HGUS210
8 6
12 .
15/a
V1. See table below for allowable loads.
N
N
H _
ay
III
a
m
"'-_' Single'2xSizes
These products are available with additional corrosion
protection. For more information, see p.15.
For stainless -steel fasteners, see p. 21.
Many of these products are approved for installation
& with Strong -Drive® SD Connector screws.
See pp. 335-337 for more information.
LUS26
1,165
865
1 990
1,070
1 1,355
1 1,165
935
1 1,070
1,150
1 1,475
865
635
725
1 785
1,000
IBC, FL,
MU826
9 J',
1,295
1484
,1,,560°
1,560
93v•,`,
:.1405
,;.15603,
t'56v-
1,560`-
: £1`
955
1,090
1,18Q
£' `
LA
HUS26
1,320
2,735
3,095
3,235
3,235
1,320
2,960
3,28-0
3,280
3,280
1,150
2,350
2,660
2780
2,780
;HGUS26
Fir
4,340';
'91860
5,170 ^
' S;390
81a u
�,'4,69d'
220 �.
5 390°
5,390
£S0� °
3 225
_ 3,610 '
-3,87 -
�3,985 ".
IBC, FL
LUS28
1,165
1,100
1,260
1,350
1,725
1,165
1,195
1,360
1,465
1,730
865
810
925
1,000
1,270
MUS28 `n'
,1,32fk
173Q'
1975,
2,125
2 25u,
.,;1„323
'`1,875 ;'
2jl35
2255
. °2,25c ,
;1zt50 A
: 1,270
1,455 .
; 1,575.
.+,95 ;'
IBC, L,
HUS28
1,760
4,095
4,095
4,095
4.095
1,760
4,095
4,095
4,095
4,095
1,480
3,520
3,520
3,520
3,520
HGUS28
1,65t3
7;2'S'
',7,275:
,7,275.'
7275 '
" 60
'7,2A)'x
7,275
7275.,
7,275 =
1.32 .
�,i 7G
3,820
3;915
4,250`':
IBC, FL
LUS210
1,165
1,335
1,530
1,640
2,090
1,165
1,450
1,655
1,775
2,270
865
985
1,120
1,215
1,500
IBC, FL,
HUS210+
?As5
5x 5t
, �5155'`'
6,830
83F":
2,6 5
.395.
='5 730i"
6 833
5: w0
-2.22C1
2 83J
2,456
2_u38
2 fi? '
LA
HGUS210
2,090
9,100
9,100
9,100
91100
2,090
1 91100
9 100
9, 0
9,10i1
1,545
6,340
6,730
6,730
6,730
113C, FL
1. For dimensions and fastener information, see table above. See table footnotes on p. 195.
HHUS/HGUS
See Hanger Options information on pp.98-99.
HHUS - Sloped and/or Skewed Seat
• HHUS hangers can be skewed to a maximum of 45' and/or sloped to a maximum of 45°
• For skew only, maximum allowable download is 0.85 of the table load
• For sloped only or sloped and skewed hangers, the maximum allowable download
is 0.65 of the table load
• Uplift loads for sloped/skewed conditions are 0.72 of the table load, not to exceed 2,475 lb.
• The joist must be bevel -cut to allow, for double shear nailing
HGUS - Skewed Seat
• HGUS hangers can be skewed only to a maximum of 450. Allowable loads are:
HGUS Seat Width Joist Down Load Uplift
W < 2" Square cut 0.62 of table load 0.46 of table load
W < 2" Bevel out 0.72 of table load 0.46 of table load
2" < W < 6" Bevel cut 0.85 of table load 0.41 of table load
2" < W < 6" Square cut 0.46 of table load 0.41 of table load
W > 6" Bevel cut 0.85 of table load 0.41 of table load
Ik"Acute
side
0°,.
Specify angle
Top View HHUS Hanger
Skewed Right
hoist must be bevel cut)
All joist nails installed on the
outside angle (non -acute side).
94
LUS/MUS/HUS/HHUS/HGUS
These products are available with For stainless Many of these products are approved for installation
10 additional corrosion protection, steel fasteners, B with Strong -Drive° SD Connector screws.
For more information, see p.15. see p.21. See pp. 335-337 for more information.
SS
'
o
z
r
z
a
0
0
U
Z
z
o
Cc
In
z
0
CO
CD
0
0
N
0
0
N
U
U
Double 2x Sizes
HHUS26-2 4-16 14 35/i6 53/s 3 (14) 0.162 x 31/2 (6) 0.162 x 31h 1,320 2,830 3,190 3,415 4,250 1,135 2,435 2,745 2,935 3,655
HGUS26-2 49/16 12 35/16 57/16 4 (20) 0.162 x 31/z (8) 0.162 x 31/z 2,155 4,340 4,850 5,170 5,575 1,855 3,730 4,170 4,445 4,795
IBC, FL,
LA
LUS210-2 I 67/I6 18 3I/a 9 2 (8) 0.162 x 31/z 1 (6) 0.162 x 31h 1,445 11,830 2,075 2,245 12,830 1;245 1,575 1,785 1,930 12,435
HHUS210-2 83/s 14 3-A,, 87A 3 (30) 0.162 x 31/z (10) 0.162 x 31/2 3,550 5,705 6,435 6,485 6,485 3,335 4,905 5,340 5;060 5,190
HGUS210-2 89fi6 12 35/I6 9�A, 4 (46) 0.162 x 31/z 1 (16) 0.162 x 31/2 4,095 9,100 1 9,100 1 9,100 9,100 1 3,520 7,460 1 7,825 7,825 7,825
Triple 2x Sizes
`I1uVJLU"J
Y'T6
IL'
Y'T6-,-J
%2<
4
{LVJ U.:IUL'7.J%2
-{Of'U.IOL XJ%2
',L,IJJ
Y,JYU=.
Y,OJU
Jj1,JU
J,J/.J
I,OJJ
I JU
I If,'.V U,"
4,4'#J
HGUS28 3 : ;
61�6
' 12
4?5/s
71/a
4
(36} 0.162x 3�1z
{12) 0.162'z31h
-3,235
;7,460
7460
7,460
:7;460,
2,7$0
6,415
6,915
,6,415
6,415
LA
HHUS210-3
83/8
14
411Ar,
87/a
3
(30) 0.162 x 31/2
(10) 0.162 x 31h
3,405
5,630
6,375
6,485
6,485
2,930
4,840
5,485
5,575
5,575
FL
HGUS210-3
87%
12
415A6
91/4
4
(46) 0.162 x 31/2
(16) 0.162 x 31h
4,095
9,100
9,100
9,100
9,100
3,520
7,825
7,825
7,825
7,825
,�HGUS212 3 '
b%
' i >
,4'1,Ae
103/a'
'4 ,,
.(50 0.1.62 x 31/z
(20) O.i62<j�31h
S,l U
,04 '
1 G45
0 4
9,04 ,_
,4,000'
`t 78,
7%`11G
?Ae'cr,
IBC FL, .
LA
Quadruple 2x Sizes
.IIU'uJLU,Y, - 072' "IC liU/]6 J'%16 I ,eft {LU1VJUGAJ,%2: 1
R°OtAU. I UL 71 a 72,1e 41 IJJ '+,a-*" i'f,OJV.'Z)'oI lU U,J (=J '1„0.�,7:.7J,1 JU IYIU 1Y,'{F}.7, 4,IBC,F
HGUS28-4 I 71/4 1 12 69/16 73Ai 4 (36) 0.162 x 31h (12) 0.162 x 31h 3,235 7,460 7,460 1 7,460N 7,460 2,780 1 6,415 6,415 1 6,415 6,415 LA
HHUS210-4 8% 1 14 61/e 1 87/e 1 3 1 (30) 0.162 x 31/2 1 (10) 0.162 x 31/z 13,405 5,630 6,375 16,485 16,485 12,930 14,840 5,485 15,575 5,575 FL
4x Sizes
IBC, F
LA
IBC, FL
LUS48
4%
1 18
39A6
63/a 1
2
(6) 0.162 x 31/2 1
(4) 0.162 x 31h
1 11,060
11,315 11,49011,610
12,0301
910 11,130
11,280
11,385
1,745
IBC, FL,
HUS48
61/a
14
39/16
7
2
(6) 0.162 x 31/2
(6) 0.162 x 31/2
1,320
1,580
1,790
1,930
2,415
1135
1,360
1,540
1,660
2,075
LA
HHUS48
61/2
14
35/s
71A
3
(22) 0.162 x 31/2
(8) 0.162 x 31/2
1;760
4,265
4,810
5,155
5,980
1,515
3,670
4,135
4,435
5,145
HGUS48
67/16
12
35/a
71f6
4
(36) 0.162 x 31/2
(12) 0.162 x 31h
3,235
7,460
7,460
7,460
7,460
2,780
6,415
6,415
6,415
6,415
HGUS412 107/i6 1 12 35/s 1106 1 4 1 (56) 0.162 x 31h (20) 0.162 x 31h 15,695 1 91045 19,045 19,045 9:045 1 4:900 1 7 780 1 7,780 17,780 7,780
HGUS414 117/Is 1 12 1 35/e 1123161 4 1 (66) 0.162 x 31/2 (22) 0.162 x 31h 1 5,695 10,125 10,125 10,125 10,125 4,900 1 8,190 8,190 18,190 8,190
Double 4x Sizes
IBC, FL,
LA
FL
1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern.
2. Wind (160) is a download rating.
3. Minimum heel height shown is required to achieve full table bads. For less than minimum heel height, see technical bulletin T-C-REDHEEL at strongtie.com.
4. Truss chord cross -grain tension may limit allowable loads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie® Connector Selector° software includes
the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie.
5. Loads shown are based on a two-ply 2x carrying member minimum for nailed hangers. With 3x carrying members, use 0.162" x 21h" nails in the header
and 0.162" x 31h" in the joist, with no load reduction. With single 2x carrying members, use 0.148" x 11h" nails in the header and 0.148" x 3" in the joist,
and reduce the load to 0.64 of the table value.
6. Fasteners: Nail dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener information.
19
HTU
Face -Mount Truss Hanger
The HTU face -mount truss hanger has nail patterns
designed specifically for shallow heel heights, so that
full allowable loads (with minimum nailing) apply to
heel heights as low as 37/8". Minimum and maximum
nailing options provide solutions for varying heel
heights and end conditions.
Alternate allowable loads are provided for gaps
between the end of the truss and the carrying member
up to 1/2" max. to allow for greater construction
tolerances (maximum gap for standard allowable loads
is %" per ASTM D1761 and D7147). See technical
bulletin T-C-HANGERGAP at strongtie.com for
more information.
Material: 16 gauge
w ' Finish: Galvanized
L
+0, Installation:
C)
• Use all specified fasteners; see General Notes
• Can be installed filling round holes only, or filling
U round and triangle holes for maximum values
N • See alternate installation for applications
using the HTU26 on a 2x4 carrying member or
HTU28 or HTU210 on a 2x6 carrying member
for additional uplift capacity
a; Options:
R
0. • HTU may be skewed up to 671/z°. See Hanger
Options on pp. 98-99 for allowable loads.
• See engineering letter L-C-HTUSD at strongtie.com
for installation with Strong -Drive® SD fasteners.
Codes: See p.12 for Code Reference Key Chart
Min. heel
height
per table
9 Many of these products are approved for installation with Strong -Drive®
SD Connector screws. See pp. 335-337 for. more information.
HTU26
truss and carrying member
HTU Installation for
Standard Allowable Loads
(for 1/2" maximum gap,
use Alternate Allowable Loads.)
Standard Allowable Loads (1/8" Maximum Hanger Gap)
2x Sizes
Typical HTU26
Minimum Nailing
Installation
Alternate Installation -
HTU28 Installed on
2x6 Carrying Member
(HTU210 similar)
J11:V4V.tIYIQA.1-`1 ,I,.
J72
'1'71 .
J."l16
;J
A 972'I;
tfuj UJ'+9 A 1"72
I,JJ3.
G,U,VU
'?,043
a ,x„77V
41jlu
f I,JJJ
'L,Jov"
4'Quu
v1vGU
0,140V-
IBC
HTU28 (Min.)
37/s
15/a
71As
31/2
(26) 0.162 x 31/2
(14) 0.148 x 11/2
1,235
3,820
3,895
3,895
3,895
1,060
2,865
2,920
2,920
2,920
FL,
HTU28 (Max.)
71/4
15/a
71%
31/2
(26) 0.162 x 31h
(26) 0.148 x 11/2
2,020
3,820
4,315
4,655
5,435
1,735
3,285
3,710
4,005
4,675
LA
HTU210 (MIn.)
, 37/s ;
15%
9'A6
31/2
.(32) 0.162x31h
= (14) 0148 x 1-?/2
1,330
j ti3Ct0
4 3
4300
3��
1,145
3 2 5._
�5
3.2215
p3,225
.HTU210,(Maz j _
X 91/a
15k
VA6
, x'f
,02) 0.162'x'3'h
`{32, 0.148 x vh
3,3,15;,�
4 705
1310
' tt�i „
,5,995
12,850 ,
4 045
565
Double 2x Sizes
HTU26 2
3?
/sf7
162 z 31h
4) 0148 x
1,515 _
2;940
t
2l n C(Min)
3;9i0
1,305',.,1,850
"
2,090
-2 255
2,465'",
FJT(J26 2 (Max,}
. 5Yz
;33Ss.
5?Aa
:(20) 0162 X 31h,
(2Q) 0.148,X 3'
2175 1
2,940
3,323 , 3 J80
4,4180_
,1,870
2,530
# 2,855
3,085
1 3,855
HTU28-2 (Min.)
37Aa
3 s
71As
31/2
(26) 0.162 x 31/2
(14) 0.148 x 3
1,530
3,820
4,310 4,310
4,310
1,315
2,865
3,235
3,235
3,235
IBC,
HTU28-2 (Max.)
71/a
135As
71As
31h
(26) 0.162 x 31/2
(26) 0.148 x 3
3,485
13,820
4,315 4,655
5,825
2,995
3,285
.3,f 0
"v5 .
,-5EI ':
FL,
LA
1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member.
2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch.
3. Uplift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern.
4. Wind (160) is a download rating.
5. For hanger gaps between 1k" and 1h", use the Alternate Allowable Loads.
6. Truss chord cross -grain tension may limit allowable bads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie® Connector Selector° software
includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie.
7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 11h" nails in the header and
reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad.
S. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information.
96
HTU
Face -Mount Truss Hanger (cont.)
Many of these products are approved for installation with Strong -Drive®
SD Connector screws. See pp. 335-337 for more information.
Alternate Installation Table for 2x4 and 2x6 Carrying Member
HTU26 (Min.) 37/s 1 (2) 2x4 1 (10) 0.162 x 31/z 1 (14) 0.148 x 1 % 1 925 1 1,470 1 1,660 1 1 90 1,875 795
HTU26 (Max.) 1 51/z 1 (2) 2x4 (10) 0.162 x 31/z (20) 0.148 x 11/z 1,240 1 1;470 1 1,660 1 1,700 90 2,220 1 1065
1. See table above for dimensions and additional footnotes.
2. Maximum hanger gap for the alternative installation is 1h".
3. Wind (160) is a download rating.
4. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information.
Alternative Allowable Loads (1/2" Maximum Hanger Gap)
Single 2x Sizes
';Ref.
1,265 1,430 11,5400 1,615
1,265 1,430 1,540 1, 910 IBC,
yam`( ag,q;�n -. a sari : FL, LA
IBC,
HTU28 (Min.) 37/a 1 % 71fe 31/z (26) 0.162 x 31/z (14) 0.148 x 11h 11110 3,770 3,770 3,770 3,770 955 2,825 2,825 2,825 2,825 FL,
LA
HTU28 (Max.) 71/4 1 % 71%6 31/z (26) 0.162 x 31/z (26) 0.148 x 11/z 1,920 3,820 4,315 4,655 5,015 1,695 2,865 1235 3,490 3,765
HTU210 (Mih.)1' ' " 3'/a 1 Ja` 9'tc ' `31/z (32) 0.162x 311z ;(14} O 1A8-x i:�h° `1,250 3`;600 `3,600 ,,-3,,60Q 3,600 ',1,075 2,700 ` 2,700 2;700 '2,70 '
Double 2x Sizes
HTU28-2 (Min.) 37/a 3-A6 71/ie 31/z (26) 0.162 x 31/z (14) 0.148 x 3 1,490 3,820 3,980 3,980 3,980 1,280 2,865 2,985 2,985 2,985 IBC,
FL,
HTU28-2 (Max.) 1 71/a 1 3-4a 1 71/ia 1 31/z (26) 0.162 x 3'/z . (26) 0.148 x 3 1.3,035 13,820 4,315 4,655 5,520 2,610 1 2,865 3,235 3,490 1 4,140 1 LA
1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member.
2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch.
3. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern.
4. Wind (160) is a download rating.
5. For hanger gaps between %" and 1h", use the Alternate Allowable Loads.
6. Truss chord cross -grain tension may limit allowable bads in accordance with ANSVI-PI 1-2014. Simpson Strong -Tie® Connector Selector" software
includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie.
7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 11/2" nails in the header and
reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad.
8. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information.
HU/HUC/HSUR/L
Medium -Duty Face -Mount Hangers
HU/HUC hangers may be installed on a masonry/concrete wall
as described below. Additionally HU hangers with one flange
concealed may be installed similarly.
HU and HUC products are heavy-duty face -mount joist hangers
made from 14-gauge galvanized steel.
• The HUC is a concealed flange (face flanges turned in)
version of the HU.
• HU is available with both flanges concealed, provided the
W dimension is 25/15" or greater, at 100% of the table load.
Specify HUC.
• HU is available with one flange concealed when the W dimension
is less than 25/15" at 100% of the table load. Specify as an 'X'
version and specify flange to conceal.
• For any HU or HUC shown in this catalog, the user may
substitute all face nails with 1/4" x 13/4" Titen® 2 screws
(Model TTN2-25134H) for concrete and 'A' x 2a44" Titen 2
screws (Model TTN2-25234M, for GFCMU. Follow all
installation instructions and use the loads from the sawn
lumber or EWF sectons.
Material: 14 gauge
Finish: Galvanized; ZMAX® and stainless steel available
Installation:
• Attach the hangers to concrete or GFCMU walls using
hex -head Titen 2 screws. Titen screws for GFCMU (1/4" x 23/4" —
Model TTN2-252341) and for concrete (1/4" x 13/4" — Model
TTN2-25134H) are not provided with the hangers.
• Drill the 3/1e°-diameter hole to the specified embedment
depth plus 1/2".
• Alternatively drill the 3/1e"-diameter hole to the specified
embedment depth and blow it clean using compressed air.
• Caution: Oversized -diameter holes in the base material
will reduce or eliminate the mechanical interlock of the
threads with the base material and will reduce the anchor's
load capacity.
• Titen Installation Tool ICts are available. They include a
3/16" drill bit and hex -head driver bit (Model TTNT01-RC);
a 3/15" x 41/2" drill bit is also available (Model MDB18412).
• A minimum edge distance of 11/2" and minimum end distance
of 37/3" is required as shown in Figure 1 for full uplift load.
• Where no uplift load is required, a minimum end distance
of 11/2" is -per itted.
Codes: See p.12 for Code Reference Key Chart
Concealed flanges
HUC410
S5_u-% °
V
HU214
Figure 1 — HUC410 Installed on
Masonry Block End Wall
Figure 2 — HUC410 Installed on
Masonry Block End Wall
23
Simpson� Construction Connectors
.. oo
HU/HUC/HSUR/L
................ _.......................................... ......................................_...... _._..... _........................... __............ _..... ---............... .... _.......... ......... _....................................... _........... _......................................._.................................. ............ _......................... _............ .... - .............
..._.
Medium -Duty Face -Mount Hangers (cont.)
These products are available with additional corrosion protection. For more information, see p.15.
HU26 HU26X (4)'/a x 23/a (4)1A x 13/a (2) 0.148 x 1'/z 335 1,000 335 1,545
HU28 HU28X; {6)aYa`X 23Ia`" (6} 1la x y 3! (-0) 0148 X.11Iz 545 1500 760 2 400
r
HU24-2 HUC24-2 (4)1/a x 23/4 (4)1/4 x-13/a (2) 0.148 x 3 380 1,000 380 1,545
HU26-3 (Min.)
HUC26-3 (Min.)
(8) % x 23/4
(8)1/a x 13/a
(4) 0.148 x 3
760
2,000
760
3,200
HU26-3 (Max.)
HUC26-3 (Max.)
(12)114 x 23/4
(12)1/4 x.13/a
(6) 0.148 x 3
1,135
-3,000
1,135
3,950
HU28-2 (Mm) ' ":
HUC28 2 (Min)
(10} lax 2?la
(10)1/a'X`13/4
(4} 0148 c`3
60
2 500 '"
760
3,725,
.,
.
_
"
HU2872 (Mix'.):
HUC28, 2 (Max } „)
t14)"�/a x 23/<
(14)1/4 x 13/4
(6) 014$ x 3 r"
"-41,135
F"
' 3 500
1;135
4 92p
HU210
HU21 OX
(8) 1/a x 2a/4
(8)1/4 x 13/4
(4) 0.148 x 11/2
5:45 •
2,000 -.
760
2,415
HU210-3 (Min.)
HUC21073 (Min.)
(14)114 x 23/4
(14)1/4 x 13/a
(6) 0.148 x 3
1,135
3,500
1'135
4,920
HU210-3 (Max.)
HUC210-3 (Max.)
(18) 1/4 x 23/4
(18)1/a x 13/4'
(10) 0.148k 3
1,'800
4,500
1,800
5,085
`
1lHU2
0148
,
-2'22
HU212-2 (Min.)
HUC212-2 (Min.)
(16)1%4 x 23/4
(16)1/4 x 13/4
(6) 0.148 x 3
1,135
4,006
1,135
4,920
HU212-2 (Max.)
HUC212-2 (Max.)
(22)1/4 x 23/4
(22)1/4 x 13/4
(10) 0.148 x 3 ..
1,350
5,085
1,350
5,085
HU214 I HU214X I (12)1/4 x 23/a I (12) A x 13/4 I (6) 0.148 x 11h f "1,135 1 2,665 I 1,135 I 2,665 I
HU214-3 (Min.)
HUC214-3 (Min.)
(18)1/4 x 23/4
(18)1/4 x 13/4
(8) 0.148 x 3.
i;515
4,500
1,515
5,085
HU214-3 (Max.)
HUC214-3 (Max.) .
(24)1/4 x 23/4
(24)114 x 13/a
(12) 0.148 x 3
2,015
5,085
2,015
5,085
HU216
HU216X'
(18)1/a x 231a
(18)1l4 z 13fa
{$) 014$`x 1'1h
1515
e 2 920
1 515
HU216-2 (Min.)
HUC216-2 (Min.)
(20)1/4 x 23/a
(20)1/4 x 13/4
(8) 0.148 x 3
1,515
4,920
1,515
4,920
HU216-2 (Max.)
HUC216-2 (Max.)
(26)1/4 x 23/4
(26)1/4 x 13/4
(12) 0.148 x 3
- 2,015
5,085
2,015
5,085
HU7 (Min.) (Not available) 1 (12) 1/4 x 23/4 (12)1/4 x 13/a 1 (4) 0.148 x 11h 545 2,980 760 2,980
HU7 (Max.) (Not available) 1 (16)1/4 x 23/a (16)1/a x 13/a I (8) 0.148 x 11/z 1 1,085 1 3,485 1 1,085 1 3,485
HU11 (Min.) (Not available) (22) Ya x 23/a (22)1/a x 13/4 (6) 0.148 x 11/z 1,135 3,230 1 1,135 3,230
HU11 (Max.) (Not available) (30)1/4 x 23/a (30) 1/4 x 13/4 (10) 0.148 x 11/z 1,445 3,735 1 1,445 37735
0
UPLIFT/5HEAR ANCHORS—V
EACH TRUSS - SEE 5/SKI
PLAN
NOTE: ADVL FRAMING NOT
SHOWN FOR CLARITY
RAISED HEEL TRUSS BEARING WASCALE, NTS
I
I.
,ED HEEL ROOF TRU5SE5
PLAN
ROOF SHEATHING- SEE f
SOFFIT/FA5CIA- SEE ARCH.
RAISED HEEL ROOF TRUSSES
-SEE PLAN
RIBBON BOARD -
SEE SCHEDULE
FOR SPACING 4
RIBBON BOARD- SEE
FASTENING TO w N
.
SCHEDULE FOR SPACING 4
TRUSSES
FASTENING TO TRUSSES
WALL 5HEATHING-5EE PLAN
-=
MIN. 15/32' CDX PLYWOOD OR
F
Y
9/16' O5B WITH 8d GUN NAILS
WALL- I
l0.131' X 2 I/2') 0 6' O.G. TO
UPLIFT/SHEAR GYP. CEILING -
SEE PLAN r
SEE
SEE PLAN
RIBBON BOARDS
ANCHOR EACH SEE PLAN 4
TRUSS- SEE PLAN SCHEDULE
n
DO NOT FASTEN RIBBON BOARD
INTO END GRAIN OF ROOF TPU55
MASONRY WALL -
BOTTOM CHORD
SEE PLAN
RAISED HEEL TRUSS BEARING B
SCALE: HIS SKI
RIBBON 5CHEDULE'
DESIGN CRITERIA
RIBBON MATERIAL
RIBBON SPACING
RIBBON ATTACHMENT
Vult=165 MPH
(2) 12d GUN (0.131' X 3')
(Vasd= MPH)
2X4 5PF12
24'
TO EACH TRUSS, (4)
EXP.. B,
ENCLOSED
NAILS AT JOINTS
Vult=ISO MPH
(2) 12d GUN l0.131' X 39
(Vasd=139 MPH)
2X4 SPF�2
I6'
TO EACH TRU55, (4)
EXP. C,
ENCLOSED
%
NAILS AT JOINTS
U
�uZ_T
Z j2 oy
OwLu-
Ui»
oe Q o =
uj o �
ZOR;�
w Z
cL 3
U
SHEET TITLE:
MON 0E FOR
RNSFO NEFL ROOFIRUSSES
SHEET INFORMATION:
SOBnO: ddl lld
BAIF ISSUED; II OB.Id
DMVM BY: -
EVIEwEDBY; M
SKA
ALPINE
.AkflWCOMPAW
I January 1Q;),2920,'
Carpenter f'o . fitractors of'Ameri I ca, inc"..
S 60' Avenue d N
Winter Haven; AL3J'986;62,0,1
Dear Matt:
It,hascome `tbmyattent-ion'"th.a't'some qgqstions wgre raised concOr Ii. idh6ter'
holes-;, ifled t futh&ch6fds1(wide .-ftcp)-qf'sy,0-2g4 Yo,-pgdirqssesl-to,,ailciwfbt,
threaded rods used Ior "tie.downs " If these:,gable ends are over continuous 5U -o-m
'e.
1. Jy d n gr. i ngpf t
with o oj��W' s,-,..ea,:h ti b a dmi e
ou - amagin-g.,'46y' bon ind"N 1; t"",
case.
; khan
fate no .
or p a es -or verucaj,-W.e4s tbep
no re_�r15 peq d" 8Th' truss supports feet of 4,6bf.:Ibads,,dhd.'�'ndadditional.
-1 -' " give
lfy6it have -questions,: leas'e m e-qcall;i
6750' Forum , Uite 305j F, Drive, We9' ' ' ' - '
rL32821-'z-(800)52 -97 --,(863),422-8685
Alpine, an ITW Company
6750 Forum Drive, Suite 305
t 1Ett�I4t1f►/�// ` ALPINE
�j �i
��/`
Or: (do,)FL 32821
Phone: 800 755-6001
WWW.a Ij7ineitw,com
,q,4, { • • ! f AN ITW COMPANY
"�` s • �c � • % FL REG# 278, Yoonhwak Kim, FL PE #86367
�4'`
.` • "".a 03/05/2021
M No.86367 =.
TE OF
t?
fir ��� M v { � �+doctr»�nt:t= been *Wcowic y slued
d , •' r �'� ssaitd ttsifg s OW Sov&". ft"d
.'JISQ,ilnforlr:�tl4ri .:: '�, �X».� 4 � '.''. .,, ,.. ✓)l�n,.�C.��.:..« hF'"',�. '.�; ( :
�� s� 1�� �ii3' k`�w5?A .. .R^°,wf
��Z� �l ��j 4- 4..1�i: ..1..Y
Customer. Carpenter Contractors of America
Job Number. N362326
Job Description_ ,7A5/320 ,4EHBH ,01H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS
Address:
�<3fi"'1�") lii{@2a�iri�5�s is'i ; � . � �+ ��. �v . � � � - R _ < _ �$ , , .��i � �.>� x, ., ;•W �' �.
Design Code: FBC 7th Ed. 2020 Res IntelliVIEW Version: 20.02.00A
JRef# 1X3G89750045
Wind' Standard; ASCE 7-16 Wind Speed (_mph): 160 Design Loading (pso.' 37.00
Building Type: Closed
'This package contains general notes pages, 34 truss drawing(s) and 5 detail(s).
1
064.21.1108.44416
Al
3
064.21.1108.44463
A3
5
064.21.1108.44259
A5
7
064.21.1108.44775
A7
9
064.21,1108.45182
A9G
11
064.21.1108.44573
62G
13
064.21.1108.45026
Ll
1.5
064.21.1108.44494
EGE
17
064.21.1108A5010
EJ3
19
064.21.1108.44493
CJ3E
21
064.21 . 1108.45087
CJ1 L
23
064.21.1108.44603
EJ7
25
064.21.1108.44432
CJ5A
27
064.21.1108.44963
CJ52.
29
064.21.1108.44868
CJ3A
31
064.21.1108.44823
CJ1
33
064.21.1108.45056
HJ3
35
A16015ENC101014
37
A16030ENC101014
39
GBLLETIN0118
2
064.21.1108A4838
A2
4
064.21.1108.44932
A4
6
064.21.1108.44728
A6
8
064.21.1108'.44682
A8G
10
064,21.1108A4744
B1
1`2
064.21.1108.44526
MEG
14
064.21.1108.45073
L2G
16
064.21.1108.44401
EJ6E
18
064.2.1.1108.44681
CJ5E
20
064,21.1108.44635
CJ1E
22
064.21.1108.45135
MG1
24
064.21.1'108.44806
EJ72
26
064.21;1108.44260
CJ5
28
064.21.1108.44478
CJ3
30
064.21.1108.44885
CJ32
32
064.21.1108.44900
HJ6E
34
064.21.1108:44619
HJ7
36
A16015ENC16011.8
38
A16030ENC160118
Florida Certificate of Product Approval #FL1999
Printed 3/5/2021 11:38:20 AM
General Notes
Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities:
The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1,
Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate
Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design
Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and
dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to
independently verify the accuracy or completeness of the information provided by others and may rely on that information
without liability. The responsibility for verification of that information remains with others neither employed nor controlled
by the Truss Design Engineer. The Truss Design Engineer's seal and signature on the attached drawings, or cover page
listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component
designs and not for the technical information furnished by others which technical information and consequences thereof
remain their sole responsibility.
The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in
accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and
loads for each truss component match those required by the plans and by the actual use of the individual. component, and
for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any
additional factors required in the particular application. Truss components using metal connector plates with integral teeth
shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to
exceed 19% and/or cause corrosion of connector plates and other metal fasteners.
The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set
forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss
component design loads, inspection of the truss components before or after installation, the design of temporary or
permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear
walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the
foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports,
installation of the truss components, observation of the truss component installation process, review of truss assembly
procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in
the installation of the truss components and/or its connections.
This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic
file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request.
Temporary Lateral Restraint and Bracing:
Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2,
B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or
other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these
drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to
and may not be relied upon for the temporary stability of the truss components during their installation.
Permanent Lateral Restraint and Bracing:
The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of
the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of
BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional.
These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building
stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building
Designer.
Connector Plate Information:
Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations,
gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60.
Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at
www. icc-es. ora.
Fire Retardant Treated Lumber:
Fire retardant treated lumber must be properly re -dried and maintained below 19% or less moisture level through all
stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special
handling care must be taken to prevent breakage during all handling activities.
• Page 1 of 3
General Notes (continued)
Key to Terms:
Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed
information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be
found in calculation sheets available upon written request.
BCDL = Bottom Chord standard design Dead Load in pounds per square foot.
BCLL = Bottom Chord standard design Live Load in pounds per square foot.
CL = Certified lumber.
Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot.
FRT = Fire Retardant Treated lumber.
FRT-DB = D-Blaze Fire Retardant Treated lumber.
FRT-DC = Dricon Fire Retardant Treated lumber.
FRT-FP = FirePRO Fire Retardant Treated lumber.
FRT-FL = FlamePRO Fire Retardant Treated lumber.
FRT-FT = FlameTech Fire Retardant Treated lumber.
FRT-PG = PYRO-GUARD Fire Retardant Treated lumber.
g = green lumber.
HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches.
HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep
adjustment.
HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds.
Ic = Incised lumber.
FJ = Finger Jointed lumber.
U# = user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value.
L/defl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the
referenced panel point. Reported as 999 if greater than or equal to 999.
Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection.
Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases.
Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases.
Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases.
NCBCLL = Non -Concurrent Bottom Chord design Live Load in pounds per square foot.
PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds.
PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds
PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds.
PP = Panel Point.
R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc).
-R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc).
Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the
indicated location (Loc).
RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non -gravity (wind or seismic)
load cases, at the indicated location (Loc).
Rw = maximum downward design Reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the
identified location (Loc).
TCDL = Top Chord standard design Dead Load in pounds per square foot.
TCLL = Top Chord standard design Live Load in pounds per square foot.
U = maximum Upward design reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the
indicated location (Loc).
VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in
inches.
VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and
maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment.
VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load.
VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment.
W = Width of non -hanger bearing, in inches.
Refer to ASCE-7 for Wind and Seismic abbreviations.
Uppercase Acronyms not explained above are as defined in TPI 1
Page 2 of 3
References:
1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.org.
2. ICC: International Code Council; www.iccsafe.org.
3. Alpine, a division of ITW Building Components Group Inc.: 514 Earth City Expressway, Suite 242, Earth City, MO
63045; www.alpineitw.com.
4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.org.
5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindustry.com.
Page 3 of 3
SEQN: 67490 / HIPS Ply: 1 Job Number: N362326 Cust: R 8975 JRef1X3G89750045 T6 I
FROM: RAA Qty: 1 ,7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44416
Truss Label: Al / YK 03/05/2021
m
m
6'3
6'1"4 11' '9 18'34 + 21'4"12 27'5"7 33'6"12 + 39-8"
6'1"44 6'1"5 6'0"11 3'1"8'f' 6'0"11 6'15 6'1"4
9'10"
9'10"
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 22.84 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
Spacing: 24.0 "
C&C Dist a: 3.97 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #1;
Webs: 2x4 SP #3; W3,W6 2x4 SP #2 N;
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint to
be equally spaced. Attach with (2) 8d Box or Gun
nails(0.113"x2ff%min.). Restraint material to be supplied
and attached at both ends to a suitable support by
erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
restraint. substitute (1) scab for (1) CLR and (2) scabs
for (2) CLR'S where shown. Scab reinforcement to be
same size, species, grade, and 80% length of web
member. Attach with 0.128x3" gun nails @ 6" oc.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
**IMPORTANT**
�o5X5 =5X5
E F
39'8"
10' 10, 9'10" 1'
19'10" 29'10" 39'8"
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.259 L 999 360
VERT(CL): 0.481 L 983 240
HORZ(LL): 0.097 K - -
HORZ(TL): 0.179 K
Creep Factor: 2.0
Max TC CSI: 0.865
Max BC CSI: 0.863
Max Web CSI: 0.392
Ver: 20.02.00A.1020.20
`Q�IIt111f11�p���D,
gees,
wa * �
No.86367Or
0
� . a
M
A
~° a STATE OF
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1546 /- /- /861 f785 /303
N 1546 /- /- 1861 f785 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
N Brg Width = 8.0 Min Req = 1.8
Bearings B & I are a rigid surface.
Bearings B & I require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 1981 - 3037 F - G 1518 - 2011
C - D 1835 - 2773 G - H 1835 - 2773
D - E 1518 - 2011 H - 1 1982 - 3037
E - F 1525 -1892
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - M 2726 -1720 L - K 2369 -1414
M - L 2369 -1433 K - 1 2726 -1702
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
M - D 453 - 75 L - F 521 - 323
D - L 555 - 703 L - G 556 - 703
E - L 521 -323 G - K 453 -76
cos/®NA� illif+k�t,o
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
RNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
in fabricating handlin shipping, installing,and bracing. Refer to and follow the latest edition of BCSI (Building
i, by TPI anc7 SECA) for safety practices pnor to performing these functions. Installers shall provide temporary
:d otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
is shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10,
each face, of truss and position as shown above and on the Joint Details, unless noted otherwise. I#efer to
plate positions. Refer to job's General Notes page for additional information.
ingg�Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the
31 PI 1, or for handling, shipping,, installapon and bracin4 of trusses. A seal on this drawin or cover page
acceptance of professional engineering responsibility solely or the design shown. The suitabilify and use of This
Ning for any structure is the responsibility of the Building�esigner per ANSI7TPI 1 Sec.2.
more information see these web
AL NE
AN MCOMPANY
6750 Forum Drive
Suite 305
Orlando FL, 32821
SEQN: 67491 / HIPS Ply: 1 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T12 /
FROM: RAA Qty: 2 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44838
Truss Label: A2 / YK 03/05/2021
6-1 "4
6'1"4
�1'+ 9'10"
9'10"
12'2"9 17' 22'8"
-1"5 4'9"7
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 22.58 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
Spacing: 24.0 "
C&C Dist a: 3.97 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N; T1,T5 2x4 SP #1;
Bot chord: 2x4 SP 2400f-2.OE;
Webs: 2x4 SP #3; W3,W6 2x4 SP #2 N;
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint to
be equally spaced. Attach with (2) 8d Box or Gun
nails(0.113"x2.5",min.). Restraint material to be supplied
and attached at both ends to a suitable support by
erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
restraint. substitute (1) scab for (1) CLR and (2) scabs
for (2) CLR'S where shown. Scab reinforcement to be
same size, species, grade, and 80% length of web
member. Attach with 0.128x3" gun nails @ 6" oc.
Loading
Truss passed check for 20 psf additional bottom chord
live load in areas with 42"-high x 24"-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
525X5 =5X5
E F
27'5"7
4'9"7
39'8"
10, + 10,
19,10" 29'10"
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.264 L 999 360
VERT(CL): 0.466 L 999 240
HORZ(LL): 0.091 K - -
HORZ(TL): 0.160 K
Creep Factor: 2.0
Max TC CSI: 0.680
Max BC CSI: 0.542
Max Web CSI: 0.323
VIEW Ver: 20.02.00A.1020.20
`e'A t,,JIjIIIIIINl►r/
4` aNNWA/f '*,
�* fa • f
a
a No, 86367 .
r R 'S
STATE OF a i9Fb
33'6"12 39'8"
6'1"5 '} 6.1"4
=yAotacf
9'10" 1'
39'8+
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1645 /- A /867 /786 /284
N 1645 /- /- /867 /786 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
N Brg Width = 8.0 Min Req = 1.5
Bearings B & I are a rigid surface.
Bearings B & I require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 2105 - 3292 F - G 1649 - 2207
C - D 1949 - 3025 G - H 1950 - 3025
D - E 1649 - 2207 H - 1 2105 - 3292
E - F 1674 - 2198
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
B - M 2958 -1835
L - K 2568 -1513
M - L 2568 -1532
K - I 2958 -1817
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp.
Webs
Tens. Comp.
M - D
456 - 81
L - F
590 - 280
D - L
494 - 708
L - G
494 - 708
E - L
590 - 280
G - K
456 - 81
'ro,'� •• OR14, C.
s/®�(AO
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracinp installed per BCSI sections B3, B7 or B10.
as applicable. Apply plates to each face, of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE
drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information.
Al ing, a division of ITW Buildin Components Group Inc. $hall not,be responsible for any deviation from this drawing, any failure to build the RNMCOMPA
truss m conformance with ANSI/ PI 1, or for handling, shipping,, installation and bracing of trusses. A seal on this drawingor cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional engineering responsibility solely -for the design shown. The suitabilitand use of This
drawing for any structure is the responsibility of the Building Designer per ANSUTPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.org; AWC _awc.org Orlando FL, 32821
SEQN: 67492 / HIPS I Ply: 1 Job Number: N362326 Cust: R 8975 JRef: 1 X3G89750045 T11 I
FROM: RAA Qty: 2 ,7A5132O ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44463
Truss Label: A3 / YK ` 03/05/2021
7'8"6
7'8"6
�1' I 9'10"
9'10"
15' 19'10" I 24'8"
7'3"10 410 4-10"
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 7.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 22.16 ft
NCBCLL: 10.00 TCDL: 4.2 psf
Soffit: 0.00 BCDL: 5.0 psf
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h
Spacing: 24.0 " C&C Dist a: 3.97 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #1; T3 2x4 SP #2 N;
Bot chord: 2x4 SP 2400f-2.OE; B2,B3 2x6 SP #2 N;
Webs: 2x4 SP #2 N; W1,W4,W7 2x4 SP #3;
Loading
Truss passed check for 20 psf additional bottom chord
live load in areas with 42"-high x 24"-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
=_5X5 1112X4 =5X5
D E T3 F
39'8"
0' 10
10" 29'19'
Snow Criteria (Pg,Pfin PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Sid: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
31'11"10 39'8"
7'3"10 7'8"6
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.278 E 999 360
VERT(CL): 0.480 E 985 240
HORZ(LL): 0.092 J - -
HORZ(TL): 0.159 J
Creep Factor: 2.0
Max TC CSI: 0.757
Max BC CSI: 0.840
Max Web CSI: 0.385
Ve r: 20.02.00A.1020.20
oe•eS
No, $6367
e —
STATE 4F a
9.10.1 1'
39'8"��
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1692 /- /- /874 /789 /255
M 1692 /- /- /874 /789 A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
M Brg Width = 8.0 Min Req = 1.5
Bearings B & H are a rigid surface.
Bearings B & H require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 2277 - 3391 E - F 2062 - 2703
C - D 2224 - 3172 F - G 2225 - 3172
D - E 2062 - 2703 G - H 2277 - 3391
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - L 3045 -1981 K - J 2456 -1533
L - K 2456 -1552 J- H 3045 -1963
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C - L 447 - 349 K - F 411 - 252
L - D 639 - 300 F - J 639 - 300
D - K 411 - 252 J - G 447 - 349
E - K 389 - 207
41 So•0 0fte
Sl$ NAI. �.
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care
Component Safety Informatior
bracing per BCSI. Unless note
attached ri id ceiling Locatior
as applicable. Apply Oates tc
drawings 160A-Z for standard
Alpine, a division of ITW Buildino Components Grouo Inc. shall not be responsible for anv
any
deviation from this drawing, any failure to build the
of trusses. A seal on this drawin or cover pacle
or the design shown. The suitability and use of this
ALPINE
MN CCWAW
6750 Forum Drive
Suite 305
Orlando FL, 32821
TPI:
SEQN: 67493! HIPS Ply: 1 Job Number: N362326 Cust: R8975 JRef1X3G89750045 T10 /
FROM: RAA Qty: 2 ,7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44932
Truss Label: A4 / YK 03/05/2021
7'4"5
7'4"5
13'
57'10
119'10" 26'8"
6'10" 6110"
=5X5 III2X4 =5X5
D E T2 F
32'3"11 + 39" '8
5711 7'4"6
1 ,2
5 2C4 W oi2G4
W3
1 A B H 1
4xs(Bz) III6X8 B2 =8X8 B3 1116X8 =4x6(B2)
39'8"
9'10: 10, 10, 91101. +1'�
9'1019,10" 29'10" 39'8"
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 7.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
Des Ld: 37.00 EXP: C Kzt: NA
Mean Height: 21.75 ft
NCBCLL: 10.00 TCDL: 4.2 psf
Soffit: 0.00 BCDL: 5.0 psf
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h
Spacing: 24.0 " C&C Dist a: 3.97 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #1; T2 2x4 SP #2 N;
Bot chord: 2x4 SP 2400f-2.OE; B2,B3 2x6 SP #2 N;
Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N;
Loading
Truss passed check for 20 psf additional bottom chord
live load in areas with 42"-high x 24"-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Cade:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in [cc Udefl U#
VERT(LL): 0.292 E 999 360
VERT(CL): 0.512 E 925 240
HORZ(LL): 0.089 J - -
HORZ(TL): 0.156 J
Creep Factor: 2.0
Max TC CSI: 0.689
Max BC CSI: 0.778
Max Web CSI: 0.748
Ve r: 20.02.0 OA.1020.20
> 11iIIifIIIIFli►p
`1 Q�A�A WAA, r�°y
M I
e
s No, 86367 2
ab
Go
STATE OF
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1657 A /- /875 /790 /225
M 1657 /- A /875 /790 A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
M Brg Width = 8.0 Min Req = 1.5
Bearings B & H are a rigid surface.
Bearings B & H require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 2451 - 3301 E - F 2514 - 2994
C - D 2372 - 3073 F - G 2372 - 3073
D - E 2514 - 2994 G - H 2451 - 3301
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - L 2960 - 2140 K - J 2537 -1811
L - K 2537 -1830 J - H 2960 - 2122
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
L-D 504 -171 K-F 590 -511
D - K 590 - 511 F - J 504 -171
E - K 645 - 388
'�,'�' ' CAR yQ
odi111i1blkW
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top -chord shall have proper)v attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. Apply Oates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. f�efer to ALPINE
drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not. be responsible for any deviation from this drawing, any, failure to build the ANMCOWP
truss in conformance with ANSI/ PI 1, or for handling, shipping,, installatlon,and bracing of trusses. A seal on this drawing,
or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional engiineering responsibilit�yy solely -for the design shown. The suitability and use of this
drawing for any sfructure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; [CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 67494 / HIPS Ply: 1 Job Number: N362326 Cust: R8975 JRef:1X3G89750045 T9 /
FROM: RAA Qty: 2 7A51320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44259
Truss Label: A5 / YK 03/05/2021
7'4"4 11' 16'11"4 22'8"12 288" 32'3"12 39'8"
7'4"4 3'7"12 5'11"4 5'9"8 5'11"4 3'7"12 7'4"4
=5X5 =5X5 =4X4 e5X5
D E F G
12
5 2X4 ia2X4 T
C H
(a) W (a)
W6
rn
TA B J �18'8"12
=4X6(B2) -8X10 B2 =8X8 B3 =8X10 = N
9'10"
9'10"
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 21.33 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
Spacing: 24.0 "
C&C Dist a: 3.97 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #1; B2,B3 2x6 SP #2 N;
Webs: 2x4 SP #3; W3,W6 2x4 SP #2 N;
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint to
be equally spaced. Attach with (2) 8d Box or Gun
nails(0.113"x2.5",min.). Restraint material to be supplied
and attached at both ends to a suitable support by
erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
restraint. substitute (1) scab for (1) CLR and (2) scabs
for (2) CLR'S where shown. Scab reinforcement to be
same size, species, grade, and 80% length of web
member. Attach with 0.128x3" gun nails @ 6" oc.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
39'8"
10' 10,
19'10" 29'10"
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Stoll: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.307 L 999 360
VERT(CL): 0.569 L 831 240
HORZ(LL): 0.094 K - -
HORZ(TL): 0.173 K
Creep Factor: 2.0
Max TC CSI: 0.890
Max BC CSI: 0.825
Max Web CSI: 0.314
VIEW Ver: 20.02.00A.1020.20
�, o • ��C Ns�, e ��
0
r
NO. 86367
STATE OF d jugs
p g «
. 6%
—4X6(B2)
9.101. 1'
39'8"+
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1546 /- /- /872 /791 /196
N 1546 !- /- /872 1791 /-
Wind reactions based on MWFRS
B Erg Width = 8.0 Min Req = 1.8
N Brg Width = 8.0 Min Req = 1.8
Bearings B & I are a rigid surface.
Bearings B & I require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 2614 - 3016 F - G 2270 - 2353
C - D 2542 - 2800 G - H 2542 - 2800
D - E 2271 - 2354 H - 1 2615 - 3016
E - F 2947 - 3107
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - M 2698 - 2287 L - K 3032 - 2643
M - L 3030 - 2659 K - 1 2698 - 2268
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
M - D 823 - 601 F - K 956 - 817
M - E 951 - 814 G - K 825 - 604
l
10, 4C S 9
/ON�A� ����
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
—WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and'SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted -otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly
attachetl ri id ceiling Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face ovtruss and position as shown above and on the Join Details, unless noted otherwise. Defer to
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the AN mvco�aANv
truss in conformance with ANSI/ PI 1, or for handling, shipping,, installation and bracing of trusses. A seal on this drawingor cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional en sneering responsibili(� solely -for the design shown. The suitability and use of )his
drawing for any s9ructure is the responsibility of the Buildingt "gner per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SECA: sbcindust .com; ]CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 674951 SPEC Ply: 1 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T20 /
FROM: RAA Qty.
1 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44728
Truss Label: A6 / YK 03/05/2021
12'i—1'_0
10'
7'1"1 101101, 19'10" 24'8" 30'8" 32'�"5 39'8"
3'8"15 f T2" i 6' 1'7" T411
T
0
TF3
=5X5 1112X4
12 D =6X6 -5X5 =5X5
5 �a2C4 T3 T
E F G H ��� PX4
T
W4
A B J
K �18'8"12
4X6(B2) =6X8 =5X8 —cv� — 0
� 39'8"
�1 0 10
991'10" 19,101,
Loading Criteria (psl)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
TCLL: 20.00
Wind Std: ASCE 7-16
Pg: NA Ct: NA CAT: NA
TCDL: 7.00
Speed: 160 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
Des Ld: 37.00
EXP: C Kzt: NA
Mean Height: 21.30 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Building Code:
Soffit: 0.00
BCDL: 5.0 psf
FBC 7th Ed. 2020 Res.
Load Duration: 1.25
MWFRS Parallel Dist: h/2 to h
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 3.97 ft
Rep Fac: Yes
Loc. from endwall: not in 9.00 ft
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration: 1.60
WAVE
Lumber
Top chord: 2x4 SP #2 N; T3 2x4 SP #1;
Bot chord: 2x4 SP #1;
Webs: 2x4 SP #3; W4 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types
9'101,
29'8"
Defl/CSI Criteria
PP Deflection in loc Udef! U#
VERT(LL): 0.384 F 999 360
VERT(CL): 0.712 F 664 240
HORZ(LL): 0.104 L - -
HORZ(TL): 0.193 L
Creep Factor: 2.0
Max TC CSI: 0.896
Max BC CSI: 0.836
Max Web CSI: 0.917
Ver: 20.02.00A.1020.20
Irl
• No, 86367 o
STATE OF
=4X6(B2)
10'
3_9
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1546 /- /- /855 l788 /193
0 1546 /- /- /859 /791 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
0 Brg Width = 8.0 Min Req = 1.8
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 2618 - 3005 F - G 3611 - 3760
C - D 2523 - 2780 G - H 2615 - 2776
D - E 2200 - 2352 H - 1 2614 - 2789
E - F 3612 - 3761 I - J 2684 - 2992
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
Chords Tens. Comp.
B - N 2688 - 2277
M - L 3452 - 3105
N - M 3197 - 2820
L - J 2675 - 2328
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
N - D 1865 -1705 M - G 400 - 308
N - E 1923 -1815 G - L 1049 - 864
E - M 645 - 713 L - H 867 - 679
F - M 561 - 352
O,af, • •. Qlp:,. $�
r, S 0 a• v
FL REG# 278, Yoonhwak Kim, FL PE 486367
03/05/2021
-WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI an c7 SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing er BCSL Unless noted otherwise, top chord shall have propq)d attached structural sheathing and bottom chord shall have a properly
attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracinfq installed per BCSI sections B3, B7 or B10,
as applicable. Apply -plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Ffefer to - ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not,be respponsible for any deviation from this drawing, any failure to build the A,,,,,,,Co,,,,,J,,,
truss in conformance with ANSI/ PI 1, or for handling, shipping,, installation and bracinccl1 of trusses. A seal on this drawing or cover page 675o Forum Drive
listing -this drawing indicates acceptance of professional engqineering responsibili((�� solely -for the design shown. The suitability and use of this
drawing for any structure is the responsibility of the Building -Designer per ANSI/TP1 1 Sec.2. Suite 305
For,more information see these web sites: Alpine: alpineilw.com; TPI: tpinst.org; SBCA: sbcindustrv.com: ]CC: iccsafe.ora: AWC: awc.ora Orlando FL, 32821
SEQN: 67496 / HIPS Ply: 1 Job Number. N362326 Cust: R 8975 JRef.'1X3G89750045 T8 /
FROM: RAA Qty: 1 ,7A,' 20 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44775
Truss Label: A7 / YK 03/05/2021
�I
1'' 0+ 18'8"7'112 I91'14 7
2330'8"
6'4" r 7,8"
32'6"14 39'8"
1'10�14 7-1"2
=5X5 =4X4 =5X5 =5X5
12 2x4 D E T2 F T3 G —')VA
� r 910"
9'10"
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 20.91 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.97 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N; T2,T3 2x4 SP #1;
Bot chord: 2x4 SP #1;
Webs: 2x4 SP #3; W3,W6 2x4 SP #2 N;
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint to
be equally spaced. Attach with (2) 8d Box or Gun
nails(0.113"x2.5",min.). Restraint material to be supplied
and attached at both ends to a suitable support by
erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
restraint. substitute (1) scab for (1) CLR and (2) scabs
for (2) CLR'S where shown. Scab reinforcement to be
same size, species, grade, and 80% length of web
member. Attach with 0.128x3" gun nails @ 6" oc.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
39'8"
10, 10,
19,101, + 29'10"
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.367 L 999 360
VERT(CL): 0.681 L 694 240
HORZ(LL): 0.110 K - -
HORZ(TL): 0.203 K
Creep Factor: 2.0
Max TC CSI: 0.898
Max BC CSI: 0.869
Max Web CSI: 0.320
VIEW Ver: 20.02.00A.1020.20
t���11111PPP►�rrror
a
No, 86367
f
a
-P STATE OF ® Li'
fi
1 ,18'8"12
91101.
39'8"
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1546 A /- /864 /827 /166
N 1546 /- /- /864 /827 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.8
N Brg Width = 8.0 Min Req = 1.8
Bearings B & I are a rigid surface.
Bearings B & I require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 2761 - 2998 F - G 2686 - 2758
C - D 2709 - 2811 G - H 2710 - 2812
D - E 2685 - 2757 H - 1 2762 - 2998
E - F 3607 - 3700
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - M 2681 - 2420 L - K 3612 - 3366
M - L 3615 - 3388 K - I . 2681 - 2402
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
D - M 776 - 568 F - K 1200 - 989
M - E 1205 - 992 K - G 773 - 564
SJoN(A� 1��e
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached rigpid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face of truss and position as shown above -and on the Join QDetalls, unless notedotherwise. f7efer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the pN iW Cap�V�NY
truss in conformance with ANSI 1, or for handling, shipping,. installatlon and bracinclof trusses. A seal on this drawin or cover pa a 6750 Forum Drive
listing this drawincl indicates acceptance of professional en rneenng responsibilitty� solely -for the design shown. The suitability and use of This Suite Fos
drawing for any sCructure is the responsibility of the Buildinggesigner per ANSIrr 11 Sec.2.
For more information see these web sites: Alpine: alpineitw.com: TPI: toinsl.ora: SBCA: sbcindustrv.com: ICC: iccsafe.ora- AWC: awc.oro Orlando FL, 32821
SEQN: 67499 / HIPS Ply: 2 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T14 !
FROM: RAA Qty: 1 ,7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB 12601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44682
Truss Label: A8G l YK 03/05/2021
2 Complete Trusses Required
7' 1TY14
7' r 6'5"14
12 =-6X6 =4X4
5 F--- C D T2
T
Sn
in
1�
1' 6'10"4 6'5"14
F' } 6,10„4 134„2 T
Loading Criteria (psi)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 20.50 ft
NCBCLL: 0.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.97 ft
Loc. from endwall: NA
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N; T2,T3 2x6 SP #2 N;
Bot chord: 2x6 SP SS;
Webs: 2x4 SP #3;
Nailnote
Nail Schedule:0.128"x3" nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 1 Row @12.00" o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Loading
#1 hip supports 7-0-0 jacks with no webs.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
1 0"ATT
6-4"2 6'42
=8X8 =4X4
E F T3
32'8" 39'8"
6'5"14 } 7'
6G6
1112X4 =_m =3X8 =8X8 1112X4
T
1 �18'8"12
39'8"
6'5"14 6'5"14 65"14 6'10"4 1'
19'10" r 26'3"14 '1
32'9'12 39'8"
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
Pg: NA Ct: NA CAT: NA
PP Deflection in loc Udefl U#
Gravity Non -Gravity
Pf: NA Ce: NA
VERT(LL): 0.434 E 999 360
Loc R+ / R- / Rh / Rw / U / RL
Lu: NA Cs: NA
VERT(CL): 0.813 E 581 240
B 3115 /- /- /- /1614 /-
Snow Duration: NA
HORZ(LL): 0.071 C - -
0 3115 /- /- A /1614 A
HORZ(TL): 0.133 C
Wind reactions based on MWFRS
Building Code:
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 1.8
FBC 7th Ed. 2020 Res.
Max TC CSI: 0.542
0 Brg Width = 8.0 Min Req = 1.8
TPI Std: 2014
Max BC CSI: 0.411
Bearings B & H are a rigid surface.
Rep Fac: No
Max Web CSI: 0.743
Bearings B & H require a seat plate.
FT/RT:20(0)/10(0)
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Plate Type(s):
Chords Tens.Comp. Chords Tens. Comp.
WAVE
VIEW Ver: 20.02.00A.1020.20
B - C 1762 - 3442 E - F 2781 - 5456
C - D 2492 - 4892 F - G 2493 - 4893
D - E 2781 - 5458 G - H 1763 - 3443
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - N 3147 -1600 L - K 4957 - 2539
N - M 3136 -1600 K - J 3137 -1601
M - L 4956 - 2539 J - H 3148 -1601
,l�t��q+,1111P1Or���`Maximum Web Forces Per Ply (Ibs)
�r v�,*�0�� • /''�/ CeM 1951Tens.Comp.
99 WeFs Tens.Comp.
Co267
M - D 488 - 672 F - K 488 - 672
. No, 8���� A D-L 554 -267 K-G 1951 -991
II r
r ® e
STATE QE a 4q ,"
/t✓►'! sa'yp� A A a `� s b
111J4f1118IIIW4
FL REG# 278, Yoonhwak Kim, FL PE 486367
03/05/2021
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing er BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attacheTri id ceiling Locations shown for permanent lateral restraint of webs shall have bracinp installed per BCSI s ctions B3, B7 or B10.
as applicable. Apply plates to each face, otruss and position as shown above and on the Join Details, unless note otherwise. Defer to ALPINE
drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Building Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the ANMCOMPAW
truss in conformance with ANSI 1, or for handling, shipping,. installation and bracing of trusses. A seal on this drawing or cover page 675o Forum Drive
listing this drawing indicates acceptance of professional encLmeering responsibilitty� solely -for the design shown. The suitability and use of this Suite Fos
drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2.
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Odando FL, 32821
SEQN: 67500 / SPEC Ply: 2 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T38 /
FROM: HMT Qty..
1 ,7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 26011 HAYDEN EXPRESS DrwNo: 064.21.1108.45182
Truss Label: A9G AK / YK 03/05/2021
2 Complete Trusses Required
7'1"4 10'10" 14'8" 19'10"4 24'8" 32'8" 39'8"
7'14 3'8"12 3'10" 5'2"4 4'9"12 8' 7'
=5X5
12 D
T 5 C4 =-8E8 1112F4 T3 =8X8 T4 =6X6 T
G H
50
N (a) W co iv
-4X6 A1)=4X8(B1) D
s3 A 1 J 11 �18'8"12
=8X10 =H1014 B3 ==-10X10 1112X4 O
39'8"
10' 10, 7'8" 5'1"12 6'10"4 1
10' 20' 27'8" 32'9"12 39'8"
Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity
TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.426 F 999 360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.789 F 598. 240 B 2756 /- /- /- /1633 /-
BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.092 D - - 0 3785 /- /- /- /2265 A
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 21.30 ft HORZ(TL): 0.170 D Wind reactions based on MWFRS
NCBCLL: 0.00 Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.6
TCDL: 4.2 psf 0 Br Width = 8.0 Min Re 2.2
Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.730 g q =
Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: o.479 Bearings B & I are i rigid surface.
Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: No Max Web CSI: o.791 Bearings B & I require a seat plate.
Members not listed have forces less than 375#
Loc. from endwall: not in 9.00 ItFT/RT:20(0)/10(0)
Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp.
Wind Duration: 1.60 WAVE HS VIEW Ver: 20.02.00A.1020.20
Lumber Wind B - C 1792 -2983 F - G 3944 -6563-
C - D 1688 - 2876 G - H 3368 - 5683
Top chord: 2x4 SP #2 N; T3,T4 2x6 SP SS; Wind loads and reactions based on MWFRS. D - E 1476 -2504 H -1 2532 -4224
Bot chord: 2x6 SP SS; B3 2x8 SP 2400f-2.OE; Wind loading based on both gable and hip roof types. E - F 3951 - 6570
Webs: 2x4 SP #3; W8 2x4 SP #2 N;
Bracing Maximum Bot Chord Forces Per Ply (Ibs)
(a) 1X4 #3SRB or better continuous lateral restraint to Chords Tens.Comp, Chords Tens. Comp.
be equally spaced. Attach with (2) 8d Box or Gun B - N 2713 -1619 L - K 3865 -2314
nails(0.113"x2.5",min.). Restraint material to be supplied N - M 5151 - 3100 K - I 3869 - 2310
and attached at both ends to a suitable support by M - L 5151 -3109
erection contractor. 10q;J J i J If } (11PI PIP P
Nailnote q�� a�H WAA t%j, Maximum Web Forces Per Ply (Ibs)
r ; a ° • * .0 / PO Webs Tens.Comp. Webs Tens. Comp.
Nail Schedule:0.128"x3" nails ® °
Top Chord: 1 Row @12.00" o.c. CEN
Bot Chord: 1 Row @12.00" o.c. �� s �, � N - D 1975 -1124 G - L 797 897
Webs : 1 Row @ 4" o.c. e + N - E 2091 - 3404 L - H 2117 -1255
Use equal spacing between rows and stagger nails ® No. $6367 s E - M 1625 -973
in each row to avoid splitting. c a
Special Loads o
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) ®� ATE OF b
TC: From 55 plf at 1.00 to 55 plf at 22.60 + r^
TC: From 28 plf at 22.60 to 28 plf at 32.67 rI 0 r^
TC: From 55 plf at 32.67 to 55 plf at 40.67 o,'�
BC: From 20 plf at 0.00 to 20 plf at 22.60 0,Sh °e 6 gBC: From 10 °rCL b
lf at 32.64
BC: From 20 plf at 32.64 to 20 lf at 22.60 to 10 plf at 39.67 8�/� v N A
TC: 177 lb Conc. Load at 22.60,24.60,26.60
TC: 169 lb Conc. Load at 28.60,30.60
TC: 380 lb Conc. Load at 32.60
BC: 1445 lb Conc. Load at 21.14
BC: 129 lb Conc. Load at 22.60,24.60,26.60
BC: 127 lb Conc. Load at 32.60,30.60
491
BC: 491 FL REG# 278, Yoonhwak Kim, FL PE #86367
lb Conc. Load at 32.64 03/05/2021
•'WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
-IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bmcingper BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the �,mco�,,,u,,.
truss in conformance with ANSI PI 1, or for handling, shipping,, installation and bracin of trusses. A sea! on this drawin or cover pare 675o Forum Drive
listing this drawing indicates acceptance of professional enccLLsneering responsibilittcy�-solely or the design shown. The suitabilify and use of this
drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.or • SBCA: sbcindustry.com; ]CC: iccsafe.org; AWC: awc.org Orlando FL, 32821
SEON: 67475! HIPS Ply: 1 Job Number: N362326 Cust: R8975 JRef1X3G89750045 T2 /
FROM: RAA city:
1 7 A51320,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44744
Truss Label: B1 / YK 03/05/2021
9' 12'8"
9' + 3'8"
1, I 9'1"12
9'1"12
Loading Criteria (psi)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 20.91 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
-
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #1; T2 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Webs: 2x4 SP #3; W4 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types
Ea
C8 T2 =5XD5
21'
3'4"8
12'6"4
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
21'
8'4"
8'2"4
20'8"8
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.036 G 999 360
VERT(CL): 0.066 G 999 240
HORZ(LL): -0.015 H - -
HORZ(TL): 0.026 E
Creep Factor: 2.0
Max TC CSI: 0.822
Max BC CSI: 0.757
Max Web CSI: 0.949
Ver: 20.02.00A.1020.20
0
01iIItIIIIPfI0
``fit O•��®�.o�`'i 00
EN
SO
No.8fi367 d ?
�oST
ATE OF�u�
"8
'2Y'
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 850 /- /- /475 /536 /137
F 778 /- /- /396 /486 A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
F Brg Width = - Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 1163 -1274 D - E 1136 -1241
C - D 1178 -1073
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - H 1088 - 958 H - G 1093 - 956
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
G - E 825 - 717 E - F 708 - 706
01 S +•.o.®
•���f'S'�NAe W�01
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have propery attached structural sheathing and bottom chord shall have a properly
attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10.
as applicabgle. Apply Oates to each face of truss and position as shown above and on the Join Details, -unless noted otherwise. Defer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not,be responsible for any deviation from this drawing, any. failure to build the ANMCOWAW
truss in conformance with ANSI 1, or for handling, shipping,, installation and bracin4 of trusses. A seal on this drawing or cover page 6750 Forum Drive
listing this drawing indicates acceptance of professional en ineenng responsibility solely -for the design shown. The suitability and use of This
drawing for any sQructure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; [CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 67478 / HIPS Ply: 1 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T5 1
FROM: RAA Qty: 1 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44573
Truss Label: 82G / YK 03/05/2021
I
l_f3
7' 14'8"
7' T8"
6'10"4
6' 10"4
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 20.50 ft
NCBCLL: 0.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: NA
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #1; T2 2x6 SP SS;
Bot chord: 2x4 SP 2400f-2.OE; B2 2x4 SP #1;
Webs: 2x4 SP #3; W2,W4 2x4 SP #2 N;
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint to
be equally spaced. Attach with (2) 8d Box or Gun
nails(0.113"x2.5",min.). Restraint material to be supplied
and attached at both ends to a suitable support by
erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
restraint. substitute (1) scab for (1) CLR and (2) scabs
for (2) CLR'S where shown. Scab reinforcement to be
same size, species, grade, and 80% length of web
member. Attach with 0.128x3" gun nails @ 6" oc.
Loading
#1 hip supports 7-0-0 jacks with no webs
Left side jacks have 7-0-0 setback with 0-0-0 cant and
1-0-0 overhang. End jacks have 7-0-0 setback with
0-0-0 cant and 1-0-0 overhang. Right side jacks have
6-4-0 setback with 0-0-0 cant and 0-0-0 overhang.
Wind
Wind loads and reactions based on MWFRS.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
=6X6 =6X6
C T2 D
0
T11"8
14'9"12
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.136 H 999 360
VERT(CL): 0.253 H 989 240
HORZ(LL): 0.043 E - -
HORZ(TL): 0.081 E
Creep Factor: 2.0
Max TC CSI: 0.786
Max BC CSI: 0.945
Max Web CSI: 0.696
Ver: 20.02.00A.1020.20
0111111i11f1!fee a/��l
EN ® 4'.�r�►
t � �
� 4 \• � s o
d e N0.86367 i r
• to .�
STATE OF ° 4WCC
�
p e ft
21'
6'4"
5'10"12
20'8"8
� 3''8
'29'
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1605 /- A /- /997 /-
F 1559 A /- /- /953 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
F Big Width = - Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 1967 - 3258 D - E 1904 - 3157
C - D 1711 - 2847
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - H 2932 -1748 H - G 2901 -1743
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
H - C 650 -106 G - E 2741 -1621
D - G 518 - 37 E - F 968 -1535
a!(411t00��1
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
—WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3 B7 or B10,
as appllcab�e. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwisd. Defer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the " „,Co,,,,,,,,,,
truss in conformance with ANSI/ PI 1, or for handling, shipping,, installation and bracinctof trusses. A seal on this drawing or cover pa%e 675o Forum Drive
listing this drawing indicates acceptance of professional engineering responsibilitty�r solely -for the design shown. The suitability and use of this
drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; ]CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 67479 / HIPM Ply: 1 Job Number: N362326 Cust: R 8975 JRefAX3G89750045 T39 /
FROM: RAA Qty..
1 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44526
Truss Label: MEG / WHK 03/05/2021
11
519"8 I 11'8"15
5'9"8 5'11 "7
e 5X8
C
1112XD4
17'8"6 17'i11"14
5'11 "7 3' 8
=4X12
E
1112X4 = 5X14 = 3X6
1113X6
17'11"14
1, 511"4 5191,11 + 5'11"7
5'11"4 11,81,15 17'8"6
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x6 SP #2 N;
Webs: 2x4 SP #3; W4 2x4 SP #2 N;
Rt Bearing Leg: 2x4 SP #3;
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 55 plf at -1.00 to
55 plf at 5.79
TC: From 27 plf at 5.79 to
27 plf at 17.99
BC: From 20 pif at 0.00 to
20 plf at 5.82
BC: From 10 plf at 5.82 to
10 plf at 17.70
TC: 141 lb Conc. Load at 5.85, 7.85,
9.85,11.85
13.85,15.85
TC: 247 lb Conc. Load at 17.71
BC: 221 lb Conc. Load at 5.82
BC: 106 lb Conc. Load at 7.85, 9.85,11.85,13.85
15.85
Wind
Wind loads and reactions based on MWFRS.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
Snow Criteria (Pg,Pfin PSF)
Defl/CSI Criteria
Pg: NA Ct: NA CAT: NA
PP Deflection in loc Udefl U#
Pf: NA Ce: NA
VERT(LL): 0.142 D 999 360
Lu: NA Cs: NA
VERT(CL): 0.262 D 813 240
Snow Duration: NA
HORZ(LL): 0.024 C - -
HORZ(TL): 0.044 C -
Building Code:
Creep Factor: 2.0
FBC 7th Ed. 2020 Res.
Max TC CSI: 0.877
TPI Bid: 2014
Max BC CSI: 0.796
Rep Fac: Varies by Ld Case
Max Web CSI: 0.824
FT/RT:20(0)/10(0)
Plate Type(s):
VIEW Ver: 20.02.00A.1020.20
WAVE
,NX
g'l�iflflllll��ll
No.86367
r
STATE OF`,��4/�
ti
�3' 8
i711"14
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
J 1248 /- /- /- /541 /-
F 1537 /- /- /- /686 /-
Wind reactions based on MWFRS
J Brg Width = 8.0 Min Req = 1.7
F Brg Width = 1.6 Min Req = 1.5
Bearings J & F are a rigid surface.
Bearing J requires a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 1184 - 2876 D - E 1282 - 2958
C - D 1282 - 2958
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - I 2687 -1092 1 - H 2711 -1683
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
D - H 551 - 622 E - F 1458 - 2167
H - E 2848 -1195
'�i o ••+ee+ r
1 ON+A1.
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI andSBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face of truss and position as shown above and on the Joint9Details, unless noted otherwise. Refer to ALPINE
drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin$gComponents Group Inc. shall not,be responsible for any deviation from this drawing, any failure to build the a,,mco,�,,,,,.
truss in conformance with ANSI 1, or for handling, shipping,. installapon and bracin of trusses. A seal on this drawin or cover pa a 675o Forum Drive
listing this drawing indicates acceptance of professional engineering responsibility solely -for the design shown. The suitability and use of this
drawing for any structure is the responsibility of the Building -Designer per ANSI/TNl 1 Sec.2. Suite 305
For more -information see these web sites: AI ine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 67476 / COMN Ply: 1 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T24 /
FROM: MRS Qty: 2 , A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.45026
Truss Label: L1 AK / YK 03/05/2021
5' 10,
5' 5' i
12 =4C4
4 T
B D ih
4 E 8-8"
F
2X4(A1) 1112X4 =2X4(A1)
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc, from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Webs: 2x4 SP #3;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types
10'
5'
5'
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
5'
10,
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.016 F 999 360
VERT(CL): 0.028 F 999 240
HORZ(LL): 0.005 F - -
HORZ(TL): 0.009 F
Creep Factor: 2.0
Max TC CSI: 0.396
Max BC CSI: 0.306
Max Web CSI: 0.079
VIEW Ver: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 429 A A /273 /206 /79
D 429 A /- /187 /206 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 8.0 Min Req = 1.5
Bearings B & D are a rigid surface.
Bearings B & D require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 1066 - 641 C - D 1066 - 641
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - F 578 - 825 F - D 578 - 825
CENs� "� A,
No. a
Nv, 86367 Ss
A
STATE 4E
/ t h ' �-
fut�+,�N+A, +�1
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING
—IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI an c7 SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections 53, B7 or B10,
as applicabgle. Apply plates to each face oT truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE
drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Building �,,,,,, Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the ro,,,P,U,,,
truss in conformance with ANSI Q PI 1, or for handling, shipping,installation and bracing of trusses. A seal on this drawing or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional encLmeering responsibilit�%y solely -for the design shown. The suitability and use of this
drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305
For mqre information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 67480 / HIPS Ply: 1 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045
FROM: MRS Qty: 1 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.45073
Truss Label: L2G AK / YK 03/05/2021
M
315
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
3' 7' I 10,
3' 41 r 3'
12
4 = 4X4 = 4X4
C D
T
B E
qU H F 88
2X4(A1) 1112X4 1112X4 =2X4(A1)
1 3'1"12
3'1"12
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft -
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Webs: 2x4 SP #3;
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 55 plf at -1.00 to
55 plf at
3.00
TC: From 27 plf at 3.00 to
27 pif at
7.00
TC: From 55 plf at 7.00 to
55 plf at
11.00
BC: From 20 plf at 0.00 to
20 plf at
3.03
BC: From 10 plf at 3.03 to
10 plf at
6.97
BC: From 20 plf at 6.97 to
20 plf at
10.00
TC: 98 lb Conc. Load at 3.03, 6.97
TC: 63 lb Conc. Load at 5.00
BC: 119 lb Conc. Load at 3.03, 6.97
BC: 50 lb Conc. Load at 5.00
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
10,
3'8"8
6' 10"4
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
31 10'�i`� 1
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): 0.037 G 999 360
VERT(CL): 0.074 G 999 240
HORZ(LL): 0.011 G - -
HORZ(TL): 0.020 G -
Creep Factor: 2.0
Max TC CSI: 0.337
Max BC CSI: 0.502
Max Web CSI: 0.070
Ver: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 628 /- /- /- /276 P
E 628 P P A /276 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
E Brg Width = 8.0 Min Req = 1.5
Bearings B & E are a rigid surface.
Bearings B & E require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B-C 506 -1313 D-E 506 -1313
C - D 461 -1249
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - H 1226 - 466 G - E 1226 - 466
H - G 1249 -461
®1���t„r� r rr►rr���f
I�
No.86367 s
STATE OF
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
"WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly
attached rigid ceilin Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. Applgy plates to each face ovtruss and position as shown above and on the Join Details, unless noted otherwise. f7efer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not,be respponsible for any deviation from this drawing, any failure to build the ANI COWAW
truss in -conformance with ANSI/ PI 1, or for handling, shipping,, installation and bracingg of trusses. A seal on -this drawing or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional engiineering responsibility solely for the design shown. The suitability and use of ittis
drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN:67477/ EJAC Ply: 1 Job Number: N362326 Cust:R8975 JRef:1X3G89750045 T17 /
FROM: RAA Qty: 1 ,�7A,511320,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44494
Truss Label: EGE / YK 03/05/2021
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wnd Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Webs: 2x4 SP #3;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
1'8"12 1'1 "8
1'8"12 "12
1112X4CD
F
3
8 A 1'2"12
1, 1 8 12 112
1'8"12 1'1 "8
Snow Criteria (Pg,af in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
T T
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.000 F
HORZ(TL): 0.000 F
Creep Factor: 2.0
Max TC CSI: 0.177
Max BC CSI: 0.014
Max Web CSI: 0.061
Ver: 20.02.00A.1020.20
8'8"
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 131 /- /- /113 /86 /49
B 42 /- /- /24 /4 P
G 49 A A /30 /33 A
Wind reactions based on MWFRS
B Brg Width = 1.5 Min Req = 1.5
B Brg Width = 14.5 Min Req = 1.5
G Brg Width = 7.5 Min Req = 1.5
Bearings B, B, & F are a rigid surface.
Bearings B, B, & F require a seat plate.
Members not listed have forces less than 375#
,J III lllIliftoj
-.`1'QNH WA k ,sfi
4
S e
N0.86367 s
OF o -� � •
STATE OF ® ice,
rr ife, S, • . * r
Vv"O, /ON A L
�®ddllHlll�
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
—WARNING*" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper) attached structural sheathing and bottom chord shall have a properl
attached rigid ceilin Locations shown for permanent lateral restraint otywebs shall have bracing installed per BCSI sections B3, B7 or B10,
as applicable. Apply Oates to each face o1 truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin$QComponents Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the
truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracingc1 of trusses. A seal on this drawing,
or cover pa e
listing this drawing indicates acceptance of professional enppmeering responsibilit� solely -for the design shown. The suitability and use of this
drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2.
For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.orq• SBCA: sbcinduslry.com; ICC: iccsafe.org; AWC• awc org
ALPINE
*NMCCWV
6750 Forum Drive
Suite 305
Orlando FL, 32821
SEQN: 674591 EJAC Ply: 1 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T7 /
FROM: RAA Qty: 7 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44401
Truss Label: EJ6E / YK 03/05/2021
6"1
t
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
4X4(B1)
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf _
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 It
Loc. from endwall: not in 4.50 It
GCp1: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131"x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
5'9"8
5'9"8
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Deft/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.007 D
HORZ(TL): 0.012 D
Creep Factor: 2.0
Max TC CSI: 0.805
Max BC CSI: 0.356
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
101
10'9"11
N �
♦ Maximum Reactions (lbs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 283 /- /- /210 /119 /117
D 106 A /- /58 A 1-
C 141 /- /- /85 /126 A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
* Q •1
• No, 86367
dot
r
r
®;� STATE OF, Q3
Ft p,
aas''j+
e14 4d�NA� 1%0l'
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
'"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in. fabricating, handling, shipping, installing and bracing. _ Refer to and follow the latest edition of
wry-c for stancaro plate positions. peter to IOD-s ueneral Notes page for additional intofmatlon.
/ision of ITW Buildingq�Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the
formance with ANSI 1, or for handling, shipping,, installation and bracinct of trusses. A seal on this drawing or cover page
rawing indicates acceptance of professional engineering responsibility solely -for the design shown The suitability and use of Zis
any structure is the responsibility of the Building -Designer per ANSUT I 1 Sec.2.
rrmation see these web sites: Alpine•-alpineitw com• TPi: tpinst org• SBCA: sbcinduslrycom; ICC• iccsafe oro• AWC• awc oro
ALPINE
mnwcaw
6750 Forum Drive
Suite 305
Orlando FL, 32821
SEQN: 674601 EJAC Ply: 1 Job Number: N362326 Cusl: R8975 JRef:1X3G89750045 T42 /
FROM: MRS Qty. 3 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.45010
Truss Label: EJ3 AK / YK 03/05/2021
12
4 F_�
C
9r$n7
B
8rprr
A U
D
2M(A1)
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
Des Ld: 37.00
EXP: C Kzt: NA
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 It
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131"x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
3'
31
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.001 D -
HORZ(TL): 0.002 D -
Creep Factor: 2.0
Max TC CSI: 0.234
Max BC CSI: 0.135
Max Web CSI: 0.006
Ver: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 185 /- A /149 /85 /67
D 50 /- /- /27 /- /-
C 63 A A /36 /54 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
`011iIItIII fff fillip
o E e 1100,
No, 66367 s s
®;• STATE OF'1", 0cv��
®144416111b
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
—WARNING`* READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in, fabricating, handling, shipping, installing.and bracing. _ Refer to and follow the latest edition of
is I ovr,-z- ror stanuaru plate positions. Meter to )oo s uenerai notes page Tor a0oitional mtormation.
a division of ITW Buildin$QComponents Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the
conformance with ANSI/TPI 1, or for handling, shipping,. installation and bracin of trusses. A seal on this drawing or cover pa e
us drawing indicates acceptance of professional engeering responsibility solely -for the design shown. The suitability and use of This
for any structure is the responsibility of the Building DDesigner per ANSIrrPI 1 Sec.2.
information see these web sites: Alpine: alpineitw.com; TPI: tpinst.or • SBCA: sbcindustrycom• ICC: iccsafe orq• AWC: awc orq
ALPINE
RNR COWAW
6750 Forum Drive
Suite 305
Orlando FL, 32821
SEQN: 67461 / JACK Ply: 1 Job Number: N362326 Cust: R8975 JRef1X3G89750045 T37 /
FROM: RAA City: 2 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44681
Truss Label: CJ5E / YK 03/05/2021
12 C
4 10'6"5
M
• � ti
� C7
B (V (V
s11 '� 818"
' D
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131"x3.0", min. toe -nails at bottom chord.
4' 11 "4
4' 11 "4
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in Icc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.004 D
HORZ(TL): 0.007 D -
Creep Factor: 2.0
Max TC CSI: 0.560
Max BC CSI: 0.250
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 252 /- /- /191 /108 /102
D 90 /- /- /49 /- /-
C 119 /- /- /71 /107 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
% Irl
4 • O
No. 86367
o
m� STATE OF
ZORIV
d��llf9it16111►►,
FL REG# 278, Yoonhwak Kim, FL PE 486367
03/05/2021
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating,-handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properir attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face oT truss and position as shown above and on the Join f Details, unless noted otherwise. Defer to
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE
Alpine, a division of ITW Buildingq�Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the ANMCOWAW
truss in conformance with -ANSI 1, or for handling, shipping,, installation and bracingcL of trusses. A seal on this drawing or cover pa a 675o Forum Drive
listing this drawing indicates acceptance of professional en ineenng responsibility solely for the design shown. The suitabiliCy and use of this
drawing for any structure is the responsibility of the Buildinguesigner per ANSUTPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com• TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 67462 / JACK Ply: 1 Job Number: N362326 Cust: R 8975 JRef1X3G89750045 T32 /
FROM: RAA Qty: 2 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44493
Truss Label: CJ3E / YK 03/05/2021
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
T
61
12
4 C
2' 11 "4
1 @T 2' 11 "4
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131"x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
T
m
in
1
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.001 D
HORZ(TL): 0.001 D
Creep Factor: 2.0
Max TC CSI: 0.290
Max BC CSI: 0.078
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
9' 10"5
r`
ti
8'8"
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 183 /- /- /147 /82 /66
D 52 /- /- /27 /- /-
C 64 /- /- /35 /61 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width =1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
��4�Si11111!!i/��I
No. 86367
a r •
CZ
STATE 4F - 4 -4
ZORIV
,QN+AO `�`1
FL REG# 278,.Yoonhwak Kim, FL PE #86367
03/05/2021
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building. -.
Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attache. rigid ceiling Locations shown for of lateral restraint of webs shall have bracin installed per BCSI sections 53, B7 or B10,
as applicable. Apply plates to each face, o truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW BuildinQQComponents Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the *NR COWV
truss in conformance with ANSI/TPI 1, or for handling, shipping,. mstallapon and bracincl of trusses. A seal on this drawin or cover pa a 675o Forum Drive
listing this drawing indicates acceptance of professional en i ,eenng responsibilittyy solely -for the design shown. The suitabili y and use of this
drawing for any structure is the responsibility of the Building�esigner per ANSI/TP1 1 Sec.2. Suite 305
For more information see these web sites: Alpine: aI ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or • AWC: awc.org Orlando FL, 32821
SEQN: 67463 / JACK Ply: 1 Job Number: N362326 Cust: R 8975 JRef IX3G89750045 T33 /
FROM: RAA Qty: 2 ,7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44635
Truss Label: CAE / YK 03/05/2021
Loading Criteria (psi)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 " -
T
Tl
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 fit
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131"x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
12
4 �
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
C
_F T
o
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.000 D
HORZ(TL): 0.000 C
Creep Factor: 2.0
Max TC CSI: 0.186
Max BC CSI: 0.025
Max Web CSI: 0.000
VIEW Ver. 20.02.00A.1020.20
9'2"9
::
♦Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 139 /- !- /129 /95 /32
D 14 /- /- /11 /3 /-
C - /-11 /- /28 /30 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
�X
° \c E IV "
a
• No.86367
lop---
V
a STATE OF o is ,
4s,ONAs tt`���
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face oP truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW BuildinlComponents Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the RNMCOWAW
trdss in conformance with ANSI 1, or for handling, shipping,, not.
ion and bracin4 of trusses. A seal on this drawing or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional enggneering responsibility solely -for the design shown. The suitability and use of this
drawing for any sgructur is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 67464 / JACK Ply: 1 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T40 I
FROM: MRS Qty: 4 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.45087
Truss Label: CJ1L AK / YK 03/05/2021
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
12
4
C
B
31 A
D
2X4(A1)
11114
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131"x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
T 9' 0"3
7"11
= 8r8"
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.000 D
HORZ(TL): 0.000 C -
Creep Factor: 2.0
Max TC CSI: 0.198
Max BC CSI: 0.025
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 141 /- A 1134 /102 /31
D 10 Al A /16 /11 /-
C - A15 A /29 /27 A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
�,��tii�vr� r►r i<i����P
• 41 ;f!r
p�
a
No. 86367
a ..
STATE OF ic-
.4o
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
—IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for of lateral restraint of webs shall hav bracing installed per BCSI sections B3, B7 or 1310,
as applicable. Apply plates to each face. o truss and position as shown above and on tt e Join Details, unless noted otherwise. Refer to - ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildingg Components Group Inc. shall not.be responsible for any deviation from this drawing, any failure to build the
truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation and bracin44 of trusses. A seal on this drawingor cover page 6750 Forum Drive
listing this drawing indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of this
drawing for any structure is the responsibility of the Building -Designer per ANSI/Wl 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.orq Orlando FL, 32821
SEQN: 67482 / MONO Ply: 2 Job Number: N362326 Cust: R 8975 JRef:1X3G69750045 T23
FROM: RAA Qty: 1 ,7A5/320 ,4EHBH ,01 H ,RLO1 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.45135
Truss Label: MG1 �AK / WHK 03/05/2021
2 Complete Trusses Required
T 6,
1
3'2 9 7'
3:28 3'9"8
1112XC
12
5 p
4BX4
r�
in
ih
4X4A(A1)
Li
1a'e 1z
E D
1114X6 1114X8
Loading Criteria (psf) Wind Criteria
TOLL: 20.00 Wind Std: ASCE 7-16
TCDL: 7.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
Des Ld: 37.00 EXP: C Kzt: NA
Mean Height: 20.70 ft
NCBCLL: 0.00 TCDL: 4.2 psf
Soffit: 0.00 BCDL: 5.0 psf
Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 " C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x6 SP #2 N;
Webs: 2x4 SP #3;
Nailnote
Nail Schedule:0.128"x3" nails
Top Chord: 1 Row @12.00" o.c.
Bot Chord: 1 Row @ 4.25" o.c.
Webs : 1 Row @ 4" o.c.
Use equal spacing between rows and stagger nails
in each row to avoid splitting.
Special Loads
------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From 55 pit at 0.00 to 55 plf at 7.00
BC: From 10 plf at 0.00 to 10 plf at 7.00
BC: 161 lb Conc. Load at 1.09
BC: 1559 lb Conc. Load at 3.00
BC: 778 lb Conc. Load at 5.00
Wind
Wind loads and reactions based on MWFRS.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
7'
3'0"12
T0"12
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/l 0(0)
Plate Type(s):
3'11"4
T
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.021 E 999 360
VERT(CL): 0:038 E 999 240
HORZ(LL): 0.005 D - -
HORZ(TL): 0.009 D
Creep Factor: 2.0
Max TC CSI: 0.244
Max BC CSI: 0.667
Max Web CSI: 0.439
EW Ver: 20.02.00A.1020.20
HWAA
4 • Or
a
No.8636% •
6�l
5P STATE OF • [c/�q
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 1508 /- /- /- /956 /-
D 1445 /- /- A /945 A
Wind reactions based on MWFRS
A Brg Width = 8.0 Min Req = 1.5
D Brg Width = - Min Req = -
Bearing A is a rigid surface.
Bearing A requires a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
A - B 931 -1442
Maximum Sot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
A - E 1311 - 843 E - D 1252 - 808
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
E - B 948 - 568 B - D 858 -1330
M•.qt• a
BdsIQN+A, `�
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWINGI
"'IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have pproper)v attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. Apply Oates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Building Components Group Inc. shall not. be respqonsible for any deviation from this drawing, any failure to build the
trriss in conformance with ANSI/) PI 1, or for handling, shipping,, mstallatlon and bracing of trusses. A seal on this drawing or cover pa e
listing this drawingg Indicates acceptance of professional englneering responsibilittyy solely -for the design shown. The suitability and use of This
drawing for any structure is the responsibility of the Building Designer perANSI/TPI 1 Sec.2.
For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcinduslry.com; ICC: iccsafe.org; AWC: awc.oro
AL NE
ANMCOMPANY
6750 Forum Drive
Suite 305
Orlando FL, 32821
SEQN: 67434 / SPEC Ply: 1 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T18 /
FROM: RAA Qty: 22 ,7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44603
Truss Label: EJ7 / YK 03/05/2021
Loading Criteria (pst)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
C
21'10"3
12
5
(h Cl)
CQ r_
Cl)
B
A 18'8"12
D
1, { 7
7'
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.50 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #1;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.016 D
HORZ(TL): 0.021 D
Creep Factor: 2.0
Max TC CSI: 0.794
Max BC CSI: 0.537
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 327 /- /- /224 /164 /210
D 129 /- /- /70 /- /-
C 177 /- /- /99 /208 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
o�AN WAS ,,r.5.
No. 86367 '
- ; STATE 4E
0NAL
f'�ei�aurta►►N��
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT * FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
t Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary.
BCSL Unless noted -otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly
id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10
e. AppTy. plates to each face of truss and position as shown above and on the JoinrDetails, unless noted otherwise. Refer to
6OA-Z for standard plate positions. Refer to job's General Notes page for additional information.
any
of
deviation from this drawing, any failure to build the
of trusses. A seal on this drawin or cover page
,r the design shown. The suitability and use of this
ALPINE
ANR COWV
6750 Forum Drive
Suite 305
Orlando FL, 32821
more
TPI:
SEQN: 67443 / SPEC Ply: 1 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T22 /
FROM: RAA City: 3 ,7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44806
Truss Label: EJ72 / YK 03/05/2021
[y
21' 10"3
12
5
6-3
� M
O
B
18'8"12
A p
=axarRl�
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
f�— 2' 7
7'
Wind Criteria -
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.29 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 it
Loc. from endwall: not in 4.50 ft
GCp!: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #1;
Bat chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.012 D
HORZ(TL): 0.016 D
Creep Factor: 2.0
Max TC CSI: 0.738
Max BC CSI: 0.527
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 395 /- /- 1297 /219 /231
D 127 /- /- /67 A /-
C 169 /- /- /90 /199 P
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
��� R�JN WAk Sri
No. 86367
STATE OF
a
15", X% ° • Z OR1aP•
flogo ill imkkjkk�
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI ancJ-SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracinq installed per BCSI sections B3, B7 or B10,
as applicabgle. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to — ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW BuildinccLLComponents Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANMCOWAW
truss in conformance with ANSI PI 1, or for handling, shipping,. installation and bracincl of trusses. A seal on this drawin or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional engsneering responsibili(� solely -for the design shown. The suitability and use Nis
drawing for any structure is the responsibility of the Building -Designer per ANSIITPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 67444 / JACK Piy: 1 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T4 /
FROM: HMT Qty: 1 ,7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.110B.44432
Truss Label: CJ5A / YK 03/05/2021
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit; 0.00
Load Duration: 1.25
Spacing: 24.0 "
12
C
III3X8(E3) D
4X4(E3)
5"
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.41 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Lt Slider: 2x4 SP #3; block length = 2.000'
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131"x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
V T4
4'3"4
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
21'0"2
ZD
N
18'8"12
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.033 B
HORZ(TL): 0.038 B
Creep Factor: 2.0
Max TC CSI: 0.598
Max BC CSI: 0.195
Max Web CSI: 0.176
Ver: 20.02.00A.1020.20
Q No.86367
v'p ®• STATE OF • c(/��
ri► ® 1-�.
Q �A
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 161 /- /- /95 /60 /114
D 80 /- /- /44 /- /-
C 113 /- A /65 /138 /-
Wind reactions based on MWFRS
A Brg Width = - Min Req = -
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Members not listed have forces less than 375#
-
ONAL
ollljmlkkO
FL REG# 278, Yoonhwak Kim, FL PE 486367
03/05/2021
-WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted o"therwise, top chord shall have properir attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling.Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 1310,
as applicabgle. Appplates to each face oT truss and position as shown above and on the Joinl Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the q, n Co,,,,,,,,,.
truss in conformance with ANSI/ PI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawing or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional engineering responsibilittyy solely for the design shown. The suitabilify and use of this
drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindusl .com; ICC: iccsafe.or ; AWC: awc.orq Orlando FL, 32821
-
ONAL
ollljmlkkO
FL REG# 278, Yoonhwak Kim, FL PE 486367
03/05/2021
-WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted o"therwise, top chord shall have properir attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling.Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 1310,
as applicabgle. Appplates to each face oT truss and position as shown above and on the Joinl Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the q, n Co,,,,,,,,,.
truss in conformance with ANSI/ PI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawing or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional engineering responsibilittyy solely for the design shown. The suitabilify and use of this
drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindusl .com; ICC: iccsafe.or ; AWC: awc.orq Orlando FL, 32821
SEQN: 67445 / JACK Ply: 1 Job Number: N362326 'Gust: R 8976 JRef:1X3G89750045 T26
FROM: RAA Qty: 8 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44260
Truss Label: CJ5 KID / WHK 03/05/2021
C
12 2011 "14
5
00
a,
N N
B
6 3 A
18'8"12
D
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 20.07 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft -
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
4'11"4
4' 11 "4
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.006 D
HORZ(TL): 0.007 D -
Creep Factor: 2.0
Max TC CSI: 0.624
Max BC CSI: 0.258
Max Web CSI: 0.000
Ver: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 252 /- /- /180 /128 /152
C 121 /- /- /67 /143 /-
D 91 /- /- /49 A /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
C Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
,Qtv+;111Ft11�/�r��
a
r
No. 86367
'fit • ,..�-... • �
%� o• STATE OF o �rr
46 • OR 6
•�o®oC o
NAL
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
**WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING!
'"IMPORTANT— FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted dtherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached ri id ceilin Locations shown for ermanent lateral restraint of webs shall hay bracin installed per BCSI sections B3, B7 or B10,
as applicable. App�y plates to each face. of truss and position as shown above and on tt a Join Details, unless noted otherwise. Defer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not. be responsible for any deviation from this drawing, any, failure to build the
truss in conformance with ANSI/ PI 1, or for handling, shipping,, installation. and bracin of trusses. A seal on this drawm or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional en ineenng responsibilit�yr solely or the design shown. The suitabili y and use of this
drawing for any structure is the responsibility of the BuildingUesigner per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ]CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 67446 / JACK Ply: 1 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T30 /
FROM: RAA Qty: 1 7A5/320 ,4EHBH ,01 H .RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44963
Truss Label: CJ52 / YK 03/05/2021
C
20'11"14
12
5
io 0
N N
B co
6
18'8"12
A p
4X4(B1)
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
12'
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 19.86 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
4' 11 "4
4' 11 "4
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.004 D
HORZ(TL): 0.005 D -
Creep Factor: 2.0
Max TC CSI: 0.572
Max BC CSI: 0.248
Max Web CSI: 0.000
Ve r: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 325 /- /- /259 /186 /173
C 109 /- !- /53 /131 /-
D 90 /- /- /47 /- A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
C Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
N WA JI
CENS
a4 � ea•ei �`
No, 85367 o
w
O v
+� STATE 4F
Q�
�0RIOQ:
°° S' •reoe•
ONAL
4IIIII4iUJkk0""
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly
attached riprd ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. App�y plates to each face oT truss and position as shown above and on the Joinf9Details, unless noted otherwise. Pefer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alping, a division of ITW Buildin Components Group Inc. shall not. be responsible for any deviation from this drawing, any, failure to build the "MCOMvun
truss m conformance with ANSIlr{ PI 1, or for handling, shipping,. installation and bracinct of trusses. A seal on this drawm or cover pa a 675o Forum Drive
listing this drawing indicates acceptance of professional en sneering responsibility solely -for the design shown. The suitabili y and use of this
drawing for any s9ructure is the responsibility of the BuildingUesigner per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org _ Orlando FL, 32821
SEQN: 67447 / JACK Ply: 1 Job Number: N362326 Cust: R 8975 JRef:1X3G89750045 T27 /
FROM: RAA Qty: 8 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44478
Truss Label: CJ3 �JB / WHK 03/05/2021
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
T
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 19.65 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131"x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
12 C
2' 11 "4
)W Criteria (Pg,Pf in PSF)
NA Ct: NA CAT: NA
NA Ce: NA
NA Cs: NA
)w Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
T
co
Defl/CSI Criteria,
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.001 D -
HORZ(TL): 0.001 D -
Creep Factor: 2.0
Max TC CSI: 0.291
Max BC CSI: 0.080
Max Web CSI: 0.000
Ve r: 20.02.00A.1020.20
20'1 "14
18'8"12
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ ! R- ! Rh / Rw / U / RL
B 182 /- /- /139 /96 /98
C 66 /- /- /34 /81 A
D 53 /- /- /28 A /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
C Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
No.86367 n
� r • � S.
� r
o
STATE OFWO
cam;
�� S' ••ooe° m
ll(II1N1N
FL REG# 278, Yoonhwak Kim, FL PE 486367
03/05/2021
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING]
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent laterel restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10,
as applicabgle. Apply plates to each face of truss and position as shown above and on the Join QDetails, unless noted otherwise. f�efer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin$Components Group Inc. shall not be responsible for any deviation from this drawing, any. failure to build the "MCOWAW
truss in conformance with ANSI/) PI 1, or for handling, shipping,, installation and bracingof trusses. A seal on this drawing or cover page 6750 Forum Drive
listing this drawing indicates acceptance of professional anc�pneenng responsibili��r solelyor the design shown. The suitability and use of This Suite Fos
drawing for any structure is the responsibility of the Building -Designer per ANSI[TPI 1 Sec.2.
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or • SBCA: sbcindust .com; ]CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 67448 /
FROM: RAA
JACK I Ply: 1
Qty: 1
Job Number: N362326
,7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS
Truss Label: CJ3A
Cust: R8975 JRef:1X3G89750045 T13 7
DrwNo: 064.21.1108.44868
/ YK 03/05/2021
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
T
6"3
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 19.86 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
12
5 B
2' 11 "4
211 "4
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
20'1 '14
Nt
00
18'8"12
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.002 C
HORZ(TL): 0.002 C
Creep Factor: 2.0
Max TC CSI: 0.343
Max BC CSI: 0.112
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 115 /- /- (69 /44 [76
B 74 /- /- (42 (88 /-
C 54 /- /- (30 /- 1-
Wind reactions based on MWFRS
A Brg Width = 8.0 Min Req = 1.5
B Brg Width = 1.5 Min Req = -
C Brg Width =1.5 Min Req = -
Bearing A is a rigid surface.
Bearing A requires a seat plate.
Members not listed have forces less than 375#
����tr��ti►�Rrrrrr
CIENSOil 10,
.o
No, 86367 0
d STATE OF cam,;
OR IV
.,°yro3+,i
ONAi ,�,
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to A LPI N G
drawings 160A-Z for standard plate positions. Refer to jobs General Notes page for additional information.
Alpine, a division of ITW Buildin$g�Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the µ, COWAW
truss in conformance with ANSIrfPI 1, or for handling, shipping,. installation and bracingg� of trusses. A seal on this drawingor cover paWe 6750 Forum Drive
listing this drawing indicates acceptance of professional engineering responsibilittyy solely for the design shown. The suitability and use of this
drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEON: 67449 / JACK Ply: 1 Job Number: N362326 Cusl: R 8975 JRef:1X3G89750045 T31 I
FROM: RAA city: 1 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44885
Truss Label: CJ32 / YK 03/05/2021
C
20'1"14
5 �
B 00 00
r- - T63 N
18'8" 12
A p
4X4(B1)
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
SDacina: 24.0 "
i 2'
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 19.44 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SIP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131"x3.0", min. toe -nails at bottom chord.
2' 11 "4
2' 11 "4
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.003 D -
HORZ(TL): 0.003 D -
Creep Factor: 2.0
Max TC CSI: 0.781
Max BC CSI: 0.129
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 268 A /- /233 /165 /118
C 44 /- /- /27 /61 A
D 51 /- A /27 /- A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
C Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
����tra4�►irrrrhe
a9° HWA p�sr
f( r
N0.66367
STATE OF
-lid
ON+AB t e
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI an c7 SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly
attachetl ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face: of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin$cLComponents Group Inc. shall not, be responsible for any deviation from this drawipg, any failure to build the A e,, COWA,,.,
truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracin4 of trusses. A seal on this drawin or cover pa9a 6750 Forum Drive
listing this drawing indicates acceptance of professional engineering responsibilittyv solely -for the design shown. The suitability and use of this
drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305
For rnore information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: Iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 67450 / JACK Ply: 1 Job Number. N362326 Cust: R 8975 JRef:1X3G89750045 T28 /
FROM: RAA Qty: 10 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44823
Truss Label: CJ1 / YK 03/05/21
Loading Criteria (psi)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
T
6" 3
i
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 19.23 it
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc., from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131"x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
12
5 C
[-11"4--{
1' i 11 "4 I
11"4 )
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/l 0(0)
Plate Type(s):
T T
co
o
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.000 D
HORZ(TL): 0.000 C
Creep Factor: 2.0
Max TC CSI: 0.168
Max BC CSI: 0.022
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
19'3"14
18'8"12
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 135 /- /- /123 /90 /44
C - /-11 1- /29 /31 /-
D 14 /- /- /10 /3 A
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
C Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
`01iiii1 P (P ryittt,P
NO. 86367
STATE OF
If��dSIOAf+Ab t�,,�
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
"'WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT"' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling shipping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly
attached ripid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. Apply Oates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW BuildingQ Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the MMCOWAW
truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracincl of trusses. A seal on this drawing,
or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional enlu,eering responsibility solely -for the design shown. The suitabilil9y and use of This
drawing for any sgructure is the responsibility of the Building Designer per ANSIrr I 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t insl.or ; SBCA: sbcindust .com: ]CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 67467 / HIP_ Ply: 1 Job Number: N362326
FROM: RAA Qty: 1 ,7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS
Truss Label: HJ6E
Cust:R8975 JRef:1X3G89750045 T1 /
DrwNo: 064.21.1108.44900
/ YK 03/05/2021
5"14 A
V r
0
2X4(A1)
2.83 0
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 7.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: - 10.00 Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 0.00 ft
NCBCLL: 0.00 TCDL: 4.2 psf
Soffit: 0.00 BCDL: 5.0 psf
Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 " C&C Dist a: 3.00 ft
Loc. from endwall: NA
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #1;
Bot chord: 2x4 SP #2 N;
Loading
Hipjack supports 5-9-8 setback jacks with no webs.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (3) 0.131"x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
8'2"5
8'2"5
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.017 D
HORZ(TL): 0.031 D
Creep Factor: 2.0
Max TC CSI: 0.865
Max BC CSI: 0.594
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
C
T10'9"7
F_ N
N �
N
81811
D
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 250 /- /-
/- /127 /-
D 115 /- /-
/32 /- /-
C 273 /- A
/- /211 /-
Wind reactions based on MWFRS
B Brg Width = 11.3
Min Req = 1.5
D Brg Width = 1.5
Min Req = -
C Brg Width = 1.5
Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
ve •o•�.•��j
u��� NSA• all*
� e �
No. 86i367 a
Q
��• ...gym .�r�
v�1 ; STATE OF • ���
~
+reel®••i tOR10�
r�®00
e'o+s '(140 Nf� 8 eel
FL REG# 278, Yoonhwak Kim, FL PE #86367
03/05/2021
""WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
luire extreme care in fabricating handling,shipping, installing,and bracing. Refer to and follow the latest edition of BCSI (Building
Safety Information, by TPI an fabricating,
fsafety practices prior to performing these functions. Installers shall provide temporary
BCSI. Unless noted otherwise, top chord shall have propery attached structural sheathing and bottom chord shall have a properly
id ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 1310,
le. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. f�efer to
MA-Z for standard plate positions. Refer to job's General Notes page for additional information.
/ision of ITW BuildinTComponents Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the
formance with ANSI PI 1, or for handling, shipping,, installation and bracinctof trusses. A seal on this drawin or cover page
rawinq indicates acceptance of professional engineering responsibility solely -for the design shown. The suitabili y and use Nis
any s ructure is the responsibility of the Building Designer, per ANSI/TPI 1 Sec.2.
ALPINE
M" COWAW
6750 Forum Drive
Suite 305
Orlando FL, 32821
SEQN: 67468 / HIP_ Ply: 1 Job Number: N362326 Cust: R 8975 JRefAX3G89750045 T43 /
FROM: MRS Qty: 2 ,7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.45056
Truss Label: HJ3 AK / YK 03/05/2021
2.83 12
C
1'5"
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 7.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 15.00 ft
NCBCLL: 10.00 TCDL: 4.2 psf
Soffit: 0.00 BCDL: 5.0 psf
Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 " C&C Dist a: 3.00 It
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Special Loads
----(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25)
TC: From -0 plf at -1.41 to 54 plf at 0.00
TC: From 2 plf at 0.00 to 2 plf at 4.18
BC: From 2 pif at 0.00 to 2 plf at 4.18
TC: -2 lb Conc. Load at 1.37
BC: 19 lb Conc. Load at 1.37
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
4'2"3
4'2"3
Snow Criteria (Pg,Pr in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Varies by Ld Case
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc L/defl L/#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.001 D -
HORZ(TL): 0.004 D -
Creep Factor: 2.0
Max TC CSI: 0,120
Max BC CSI: 0.144
Max Web CSI: 0.000
Ver: 20.02.00A.1020.20
T 9'8"4
C\I
M
8r8rr
♦ Maximum Reactions (lbs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
E 142 /- /- A /86 A
D 69 A A /- /6 /-
C 36 A A A /8 A
Wind reactions based on MWFRS
E Brg Width = 10.6 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing E is a rigid surface.
Bearing E requires a seat plate.
Members not listed have forces less than 375#
0111IIItfrf)ffffl
ease �',o•
® �\CE Ns
s�f rp��i�
,a No. �6367
r
•
v?S , STATE 4F •Goa
i �OR1ap�`°.�a
/11111118111
FL REG# 278, Yoonhwak Kim, FL PE 486367
03/05/2021
-WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING
"IMPORTANT'"' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
quire extreme care in fabricating, handlin shipping, instaliing,and bracing. Refer to and follow the latest edition of BCSI (Building
d Safety Information, by TPI an SBCA) fo'r safety practices pnor to performing these functions. Installers shall provide temporary
r BCSI. Unless noted o herwise,.top chord shall have proper)y attached structural sheathing and bottom chord shall have a properly
id ceiling Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
e. AppTy plates to each face of truss and position as shown above and on the Joint9Details, unless noted otherwise. Refer to
60A-Z for standard plate positions. Refer to job's General Notes page for additional information.
ivision of ITW BuildincLComponents Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the
tf 1rmin ce with ANSI/TPI 1, or for handling, shipping,, installation and bracin4 of trusses. A seal on this drawing or cover page
Jrawin9: indicates acceptance of professional enc,�rneenng responsibilitx solely or the design shown. The suitability and use of this
ALPINE
mmvconwa
6750 Forum Drive
Suite 305
Orlando FL, 32821
more information see these -web sites: Alpine: aloineitw.com: TPI:
SEQN: 67452 / SPEC Ply: 1 Job Number: N362326 Cust: R 8975 JRef1X3G89750045 T19 !
FROM: RAA Qty: 5 7A5/320 ,4EHBH ,01 H ,RL01 / 4EHB / 2601 / HAYDEN EXPRESS DrwNo: 064.21.1108.44619
Truss Label: HJ7 / WHK 03/05/2021
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
5'7"8
5'7"8
9'10"1
4'2"9
21'10"2
12
3.54 p ; 4X4
C
ir) 90
ih
B
ALl N 1 1418'8"12
G F F
�— VT
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 20.50 ft
TCDL: 4.2, psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 It
Loc, from endwall: NA
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP 92 N;
Bot chord: 2x4 SP #2 N;
Webs: 2x4 SP #3;
Loading
Hipjack supports 6-11-8 setback jacks with no webs.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
Additional Notes
Refer to General Notes for additional information
Provide (3) 16d common 0.162"x3.5", toe -nails at TC.
Provide (3) 16d common 0.162"x3.5", toe -nails at BC.
5'5"12 3'6"3 1 1(
'1
5'5"12 18'11"15 9'1
Snow Criteria (Pg,Pf in PSF)
Deft/CSI Criteria
Pg: NA Ct: NA CAT: NA
PP Deflection in loc Udefl U#
Pf: NA Ce: NA
VERT(LL): 0.044 G 999 360
Lu: NA Cs: NA
VERT(CL): 0.082 G 999 240
Snow Duration: NA
HORZ(LL): 0.008 C - -
HORZ(TL): 0.014 C
Building Code:
Creep Factor: 2.0
FBC 7th Ed. 2020 Res.
Max TC CSI: 0.512
TPI Std: 2014
Max BC CSI: 0.699
Rep Fac: No
Max Web CSI: 0,268
FT/RT:20(0)/10(0)
Plate Type(s):
VIEW Ver: 20.02.00A.1020.20
tArnvF
o' OA�WA(ffr%I i
m �
No, 86367 °
• a
STATF OF.rv° ct,�
rs�®�•�®1ORtDP
be
"IS4Qi V �1 F• � e
ll(1(y10111`
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 324 /- /- /- /205 /-
E 363 /- A /- 1142 /-
D 211 /- A A /206 A
Wind reactions based on MWFRS
B Brg Width = 10.6 Min Req = 1.5
E Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B - C 439 - 713
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - G 664 -404 G - F 654 -406
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
C - F 458 -737
FL REG# 278, Yoonhwak Kim, FL PE 486367
03/05/2021
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING
"IMPORTANT`" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, stalling and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, bV TPI anc7 SBCA) fo'r safety practices pnor to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly
attached rigid ceiling Locations shown for permanent laterel restraint of webs shall have bracing installed per BCSI sections B3, 67 or 810,
as applicable. Apply plates to each face optruss and position as shown above and on the Joint Details, unless noted otherwise._- Defer -to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW BuildinIc�Components Group -Inc. shall not, be responsible for any deviation from this drawing, any failure to build the MMCOAWAW
truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracing of trusses. A seal on this drawin or cover pare 675o Forum Drive
listing this drawing indicates acceptance of professional en ,eering responsibilittyy solely for the design shown. The suitability and use of 4 is
drawing for any structure is the responsibility of the Building�esigner per ANSI/T 11 Sec.2. Suite 305
For -more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com• ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
e
Gable Stud Reinforcement Detail
ASCE 7-10i 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1,00
Or, 140 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00
Uri 140 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00
n- tan -L Ul-A c. -A IM, u _- - --
S
2x4 Brace
Gable Vertical
Spacing Species Grade
,
No
Braces
(1) lx4 'L' Brace w
(1) 2x4 'L' Brace w
(2) 2x4 'L' Brace ww
(1) 2x6 'L' Brace w
(2) 2x6 'L' Brace w
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
S P F
#1 #2
1.9'
3•
U
#3
3' 8'
5' 9'
6' 2'
7' 8'
i' 11'
9' 1'1
9' 6'
12, 0'
12' 6'
14' 0'
14' 0'
Stud
3' 8'
5' 9'
6' 1'
7' 8'
7' 11'
9' 1'
9' 6'
12' 0'
12' 6'
14' 0'
14' 0'
Oj
0
Standard
3' 8'
4' 11'
5' 3'
1 6' 7'
7111
8' 11'
9' 6'
10' 4'
11' 1'
14' 0'
14' 0'
#1
4' 0'
6' 8'
6' 11'
7' 10'
8' 2'
9' 4'
9' 8'
12' 4'
12' 9'
14' 0'
14' 0'
J
S P
#2
3' 10,
6' 7'
6' 10'
7' 9'
8' 1'
9' 3'
9' 7'
12' 2'
12' 8'
14' 0'
14' 0'
#3
3' 9'
5' 3'
5' 7'
6' 11'
7' 5'
9' 2'
9' 7'
10, 11'
11' 8'
14' 0'
14' 0'
d
P
Stud
3' 9'
5' 3'
5' 7'
6' 11'
7' 5'
9' 2'
9' 7'
10, 11'
11' 8'
14' 0'
14' 0'
Standard
3' 6'
4' 7'
4' 11'
6' 2'
6' 7'
6' 4'
8' 11'
9' 8'
10' 4'
13' 1'
14' 0'
U
_
S P P
#1 / #2
4' 5'
7' 6'
7' 9'
8' 10,
9' 3'
10' 7'
11' 0'
13' Il'
14' 0'
14' 0'
14' 0'
+>
_
#3
4' 2'
7' 1'
7' 9'
8' 9'
9' 1'
10' 5'
10' 10,
13' 9'
14' 0'
14' 0'
1 14' 0'
U
L1 P
Stud
4' 2'
7' 1'
7' 6'
8' 9'
9' 1'
10' 5'
10, 10,
13' 9'
14' 0'
14' 0'
14' 0'
Q1
0
�I
Standard
4' 2'
6' 1'
6' 5'
8' 1'
6' 8'
10, 5'
10' 10'
1 12' 8'
13' 7'
14' 0'
14' 0'
#1
4' 7'
7' 7'
7' 11'
9' 0
9' 4'
10, 6'
11' 1'
14' 0'
14' 0'
14' 0'
14' 0'
S P
#2
4' 5'
7' 6'
7' 9'
6' 10,
9' 3'
10' 7'
ill 0'
13' 11'
14' 0'
14' 0'
14' 0'
Q1
D rr L
#3
4' 4'
6' 5'
6' 10'
8' 6'
9' 1'
10' 6'
10, 11'
13' 4'
14' 0'
14' 0'
14' 0'
Stud
4' 4'
6' 5'
6' 10'
8' 6'
9' 1'
10, 6'
10, 11'
13' 4'
14' 0'
14' 0'
14' 0'
Standard
4' 2'
5' 8'
6' 0'
7' 6'
8' 0'
10, 2'
10, 10,
11' 10,
12' 7'
14' 0'
14' 0'
[-
S P
#1 / #2
4' 10'
8' 3'
8' 7'
9' 9'
10' 2'
10' 7'
12' 1'
14' 0'
14' 0'
14' 0'
14' 0'
CS
_
r
#3
4' 7'
8' 2'
8' 5'
9' 6'
10, 0'
11' 6'
12, 0'
14' 0'
14' 0'
14' 0'
14' 0'
U
0
I�
H
d
4' 7'
8' 2'
6' 5'
9' 8'
10, 0'
11' 6'
12, 0'
14' 0'
14' 0'
14' 0'
14' 0'
Standard
4' 7'
7' 0'
7' 5'
9' 4'
10, 0'
11' 6'
12' 0'
14' 0'
14' 0'
14' 0'
14' 0'
X
#1
5' 1'
8' 5'
B' 8'
9' 11'
10' 3'
Ill 9'
12' 3'
14' 0'
14' 0'
14' 0'
14' 0'
d
S P
#2
4' 10'
8' 3'
8' 7'
9' 9'
10' 2'
11' 7'
12, 1'
14' 0'
14' 0'
14' 0'
14' 0'
#3
4' 9'
7' 4'
7' 10'
9' 8'
10, 1'
11' 7'
12, 0'
14' 0'
14' 0'
14' 0'
14' 0'
.--I
D f[- L
Stud
4' 9'
7' 4'
7' 10'
9' 8'
10' 1'
11' 7'
12' 0'
14' 0'
14' 0'
14' 0'
14' 0'
Standard
4' 7'
6' 6'
6' 11'
8' 8'
9' 3'
11' 6'
12' 0'
13' 7'
14' 0'
14' 0'
14' 0'
Diagonal brace option -
vertical length may be
doubled when diagonal
brace Is used. Connect
diagonal brace for 600#
at each end. Max web
total length Is 14'.
Vertical length shown
In table above.
Connect dianonnl at
AN 1TWC01
115141 Eanh\ Cily1 Expressway
\ 1 Suile1242
\\ Eanh\ City,\ M0163045
..,.
About
Truss
� 1t3� 31E
,L, L IIIItP!!►!
Brace �4 WA�l��/!�
•
2x6 DF-L #2 or t ©• • • 4
better diagonal "r oOA� •
brace) single I
or double cut 6' �
• �3 7
451* (as shown) at L 1
upper end, .1 M rl n!
on l,r , Bearing a
Refer to chart abo o, In �v Rica
"YARNING" READ AND FOLLDV ALL NDTES oN THIS 1RAVM r a •
wwDfMTANTww FURNISH THIS DRAVM M ALL CWMACT1RS INCLUDDIG THE INSTALLERS. �/ /� •
Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer to and 0 �(i • S + o R 0
nlow the latest edition of BCSI (BuRdtng Component Safety Information, by TPI and SBCA) for safety;Uc✓ l?)S %� f+
less ce. notedlootherr to wiseF o performing
shathese ll havepropertyattached ers shatt structural ovide pshenthlry g bracing ber ottom Schord�'A� 1 ;,
iall haven properly attached rigid ceiling. Loctbns shown for permanent Intern: restraint of webs
,all have hating Installed per BCSI sections B3, B7 or H10, as applicable. Apply plates to each face
truss and position as shown above and on the Joint Details, unless noted otherwise.
rfer to drawings 16OA-Z for standard plate positions.
Alpine, a division of ITV Binding Components Group Inc shall not be responsible for any deviation fron
is drawing, any failure to build the truss in confornance with ANSI/TPI 1, or for handling, shipping,
-tallation 6 bracing of trusses.
A seal on this drawing or cover page Ustkp this drawing, Indicates acceptance of professional
glneeNng responsWlity solely far the design shorn The sultabiUty and use of this drawing
r any structve is the responsWlty of the Buntline Designer per ANSI/TPI 1 Sec2.
For more Information see this Job's general notes l n and these web s:ftYl 5 7�p �8 l oonhwak Kim, FL PE #863(
ALPINE vD v walpineltw,con) TPw.tpinst.org) SBCM vwsbdndustry.orgi ICd wwdc f
Bracing Group Species and Grades,
Group Al
S ruce-Pine-Fir Hem -Fir
#1 / #2 iStandard #2 Stud
#3 Stud #3 IStandardl
Dou lns Fir -Larch Southern Pinew3mm
#3 #3
Stud Stud
Standard Standard
Group B:
Hem -Fir
#1 & Btr
#1
Douglas Fir -Larch Southern Pinewww
#1 #1
#2 #2 EL
1x4 Braces shall be SRB (Stress -Rated Board).
wwFor Ix4 So. Pine use only Industrial 55 or
Industrial 45 Stress -Rated Boards, Group B
values may be used with these grades.
Gable I russ Detail Notes:
Wind Load deflection criterion Is L/240.
Provide uplift connections for 75 plf over
continuous bearing (5 psf TC Dead Load),
Gable end supports load from 4' 0' outlockers
with 2' 0' overhang, or 12' plywood overhang.
Attach 'L' braces with 10d (0,128'x3.0' min) nails.
)K For (1) 'L' brace- space nails at 2' o.c.
In 18' end zones and 4' o.c, between zones.
)K)KFor (2) 'L' bracest space nails at 3' o.c.
In 18' end zones and 6' o.c. between zones.
'L' bracing must be a minimum of 807 of web
member length.
Gable Vertical Plate Sizes
1P
Vertical Len th
No S lice
Less than 4' 0'
2X3
Greater than 4' 01, but
less than IS' 6'
3X4
Greater than 11' 6'
4X4
II+ Refer common truss design for
peak, splice,
ice, and heel plates,
b
Refer to the Building Designer for conditions
i
not addressed by this detail.
REF ASCE7-10-GAB16015
DATE 10/01/14
DRWG A16015ENC101014
AX. TOT, LD, 60 PSF
AX. SPACING 24,0'
Gable Stud Reinforcement Detail
ASCE 7-16: 160 mph Wind Speed, 15/ Mean Height, Enclosed, Exposure C, Kzt = 1,00
Or, 140 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00
Or, 140 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00
I1r, 1?n mnh Winn Snoorl_ 15' Monn 14.1M,+ Pn +L.ii., ro._L.--A r.,,--- n vim+ - ran
S
2x4 �Brace
Gable VerticalNo
Spacing Species
Braces
(1) lx4 'L' Brace w
(1) 2x4 'L' Brace w
(2) 2x4 'L' Brace w■
(1) 2x6 'L' Brace w
<2) 2x6 'L' Brace *31
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
S P
#1 / #2
'
'
-
#3
3' 8'
5' 9'
6' 2'
7' 8'
7' 11-
9' 1'
9' 6-
12, 0'
12' 6'
14' 0'
14' 0'
HF
Stud
3' 8'
5' 9'
6' 1'
7' 8'
7' 11'
9' 1'
9' 6'
12, 0'
12' 6'
14' 0'
14' 0'
0
Standard
3' 6'
4' 11'
5' 3'
6' 7'
7' V
8' 11'
9' 6
10' 4'
11' 1'
14' 0'
14' 0'
#1
4' 0'
6' 8'
6' 11'
7' 10'
8' 2'
9' 4'
9' 8'
12' 4'
12' 9'
14' 0'
14' 0'
J
S P
#2
3' 10'
6' 7'
6' 10'
7' 9'
8' 1'
9' 3'
9' 7'
12' 2'
12' 8'
14' 0'
14' 0'
#3
3' 9-
5' 3'
5' 7'
6' 11'
7' 5'
9' 2'
9' 7'
10, 11'
11' 8'
14' 0'
14' 0'
d
P
Stud
3' 9'
5' 3'
5' 7'
6' 11'
7' 5-
9' 2'
9' 7'
10, 11'
11, 8'
14' 0'
14' 0'
Standard
3' 6'
4' 7'
4' 11-
6' 2-
6' 7'
8' 4'
8' 11'
9' 8'
10' 4'
13' 1'
14' 0'
U
#1 / #2
4' 5'
7' 6'
7' 9'
8' 10'
9' 3'
10' 7'
11' 0'
13' 11'
14' 0'
14' 0'
14' 0'
_
S P P
#3
4' 2'
7' V
7' 9'
8' 9'
9' 1'
10' 5'
10, 10'
13' 9'
14' 0'
14' 0'
14' 0'
U
LI [
H
Stud
4' 2'
7' 1'
7' 6'
8' 9'
9' 1'
10' 5'
10, 10'
13' 9'
14' 0'
14' 0'
14' 0'
QJ
0
I
Standard
4' 2'
6' 1'
6' 5-
8' 1'
8' 8'
10' 5'
10, 10'
12' 8'
13' 7'
14' 0'
14' 0'
#1
4' 7'
7' 7'
7' 11'
9' 0'
9' 4'
10, 8'
ill 1'
14' 0'
14' 0'
14' 0'
14' 0'
S P
#2
4' 5'
7' 6-
7' 9'
8' 10'
9' 3'
10' 7'
11' 0'
13' 11'
14' 0'
14' 0'
14' 0'
OJ
D
D P L
#3
4' 4-
6' 5'
6' 101.
8' G.
9' 1'
10' 6'
10, 11'
13' 4'
14' 0'
14' 0'
14, 0'
Stud
4' 4'
6' 5'
6' 10'
8' 6'
9' 1'
10' 6'
10' 11-
13' 4'
14' 0'
14' 0'
14' 0'
Standard
4' 2'
5' 8'
6' 0'
7' 6'
8' 0'
10' 2'
10' 10'
11' 10'
12' 7'
14' 0'
14' 0'
Q
#1 / #2
4' 10'
8' 3'
8' 7'
9' 9'
10' 2'
10' 7'
12' 1'
14' 0'
14' 0'
14' 0'
14' 0'
d
S P P
#3
4' 7'
B' 2-
8' 5'
9' 8'
10, 0'
11' 6'
12, 0'
14' 0'
14' 0'
14' 0'
14' 0'
L�
U
u
d
4' 7'
8' 2'
8' 5'
9' 8'
10, 0'
11' 6'
12' 0'
14' 0'
14' 0'
14' 0'
14' 0'
0
�l
Standard
4' 7'
7' 0'
7' 5'
9' 4'
10, 0'
11' 6'
12' 0'
14' 0'
14' 0'
14' 0'
14' 0'
X
#1
5' 1'
8' 5'
8' 8'
9' 11'
10' 3'
11' 9'
12' 3'
14' 0'
14' 0'
14' 0'
14' 0'
d
S P
#2
4' 10'
8' 3'
8' 7'
9' 9'
10' 2'
11' 7'
12, 1'
14' 0'
14' 0'
14' 0'
14' 0'
#3
4' 9'
7' 4'
7' 10'
9' 8'
10' 1'
11' 7'
12, 0'
14' 0'
14' 0'
14' 0'
14' 0'
r-I
D P L
Stud
4' 9'
7' 4'
7' 10'
9' 8'
10' 1'
11' 7'
12, 0'
14' 0'
14' 0-
14' 0'
14' 0'
Standard
4' 7'
6' 6-
6' 11'
8' 8'
9' 3'
11' 6'
12' 0'
13' 7'
14' 0'
14' 0-
14' 0'
Diagonal brace optlon,
vertical length may be
doubled when diagonal
brace Is used. Connect
diagonal brace for 600#
at each end. Max web
total length Is 14'.
Vertical length shown
In table above.
Connect dlo.gonnl at
midoolnt of vertical web.
AN ITW CO
%% 514% Earth% City\ Expressway
I Suite\ 242
% % Eanh% City,% MO% 63045
Truss
about!{_
L
S
'L' Brace End
iq
Zones, typ.
2x6 DF-L #2 or
better diagonal
r
`1
A
O
bracer single
ti
O
or double cut
<as shown) at
L
upper end.
oniyfs&Bel
\41.1 `U` Refer to chart aboii2'
WAVARNBU— READ AND FR10V ALL NOTES ON THIS DRAVM w'
—DWMTANTn FURNISH TIRS DRAVIN6 TO ALL CONTRACTORS DICIAMM THE INSTALLER&. i
Trusses require extreme care In fabricating, handling, shipping, Installing and bracing, Refer to and
,[low the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety
•actices prior to performing these functions. Installers shall provide temporary, bracing per BCSL
,less noted otherwise, top chord shall have properly attached structural sheathing and bottom chor
,all have a properly attached rigid ceiling, Locations shown for permanent lateral restraint of webs
,all have bracing Installed per BCSI sections B3, B7 or HIO, as oppllcable, Apply plates to each face
truss and position as shown above and on the Joint Details, unless noted otherwlse.
Wer to drawings 160A-Z for standard plate positions.
Alpine, a division of ITV Building Components Group Inc shall not be responsible for any deviation frc
Os drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping,
-tallatlon R bracing of trusses.
A seal on this drawing or cover page Ustnng this drawing, indicates acceptance of professional
ngineewng responswity solely for the design shown The suitnWllty and use of this drawing
r any struci,re L' the responsibility of the BuildingDesigner per ANSI/TPI 1 Sec2.
For no" Information see this Job's general notes page and these webs Q la �J7R
ALPINE, wwwalpineltw.coni TPD wwwApinst,orgi SECA, www,sbcindustryargi ICC, wwwJ 7
111111//o
IWq�'��Prr
a
9Au
�0RIV�:el'
� • 0
'S/0N�A�
Bracing Group Species and Grades,
Group At
S ruce-Pine-Fir Hem -Fir
#1 / #2 Standard #2 Stud
#3 Stud 1 11 #3 Standard
Dou ins Fir -Larch Southern Pinewww
#3 #3
Stud Stud
Standard Standard
Group B,
Hem -Fir
#1 & Btr
#1
Do"" u ins Flr-Lurch Southern Pinewww
#1 #1
#2 #2
lx4 Braces shall be SRB (Stress -Rated Board),I
wwFor lx4 So. Pine use only Industrial 55 or
Industrial 45 Stress -Rated Boards. Group B
values may be used with these grades.
Gable Truss Detail Notes+
Wind Load deflection criterion Is L/240.
Provide uplift connections for 75 plf over
continuous bearing <5 psf TC Dead Load).
Gable end supports load from 4' 0' outlookers
with 2' 0' overhang, or 12' plywood overhang.
Attach 'L' braces with 10d (0.128'x3.0' min) nails.
)K For (1) 'L' brace, space nails at 2' o.c.
In 18' end zones and 4' o.c. between zones,
)K)KFor <2) 'L' braces, space nails at 3' o.c.
In IS' end zones and 6' o.c. between zones.
'L' bracing must be a minimum of 80X of web
member length.
II Gable Vertical Plate Sizes 11
Vertical Length
No S lice
Less than 4' 0'
2X3
Greater than 4' 0', but
less than 11' 6'
3X4
Greater than "' 6'
4X4
+ Refer to common truss design for
peak, splice, and heel plates. 11
Refer to the Building Designer for conditions
not addressed by this detail.
TOT, LD, 60 PSF
SPACING 24,0'
REF ASCE7-16-GAB16015
DATE 01/26/2018
DRWG A16015ENC160118
Gable Stud Reinforcement Detail
ASCE 7-10: 160 mph Wind Speed, 30' Mean Height, Enclosed, Exposure C, Kzt = 1,00
Or 140 MPH Wind Speed, 30' Mean Height, Partially Enclosed, Exposure C. Kzt = 1.00
' Or: 140 mph Wind Speed, 30' Mean Height, Enclosed, Exposure D, Kzt = 1.00
❑r+ 12n mnh Wind Snood. 9n' Monn Holnk+ Pnr+inli" Cnr1nen,4 C....n v-.� - i nn
S
2x4 Brace
Gable Vertical
Spacing Species Grade
No
Braces
(1) lx4 'L' Brace iK
(1) 2x4 'L' Brace x
(2) 2x4 'L' Brace xx
(1) 2x6 'L' Brace X
(2) 2x6 'L' Brace ■
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
#1 / #2
3' 8'
6' 3'
6' 6'
75'
7' 8'
8' 9'
9' 2'
11' 7'
12' 0'
13' 9'
14' 0'
0)
U
S P F
#3
3' 6'
5' 5'
5' 9'
7' 2'
7' 7'
8' 8'
9' 1'
11' 3'
11' il'
13' 7'
14' 0'
HF
Stud
3' 6'
5' 4'
5' 8'
7' 2'
7' 7'
8' 8'
9' 1'
11' 2'
11' 11'
13' 7'
14' 0'
o
Standard
3' 6'
4' 7'
4' 11'
6' 2'
6' 7'
8' 4'
8' ill
9' 8'
10' 4'
13, 1'
14' 0'
#1
3' 10,
6' 4'
6' 7'
7' 6'
7' 9'
8' 11'
9' 3'
11' 9'
12' 2'
13' 11'
14' 0'
J
S P
#2
3' 8'
6' 1'
6' 6'
7' 5'
7' 8'
8' 9'
9' 2'
11' 7'
12' 0'
13' 9'
14' 0'
#3
3' 7'
4' 10'
5' 2'
6' 5'
6' 11'
8' 9'
9' 1'
10, 1'
10, 10'
13181
14' 0'
d
P
Stud
3' 7'
4' 10'
5' 2'
6' 5'
6' ll'
8' 9'
9' 1'
10, 1'
10, 10'
13' 8'
14' 0'
Standard
3' 3'
4' 3'
4' 7'
5' 8'
6' 1'
7' 9'
8' 3'
8' 11'
9' 7'
12, 2'
13, 0'
�-%
#1 / #2
4' 2'
7' 2'
7' 5'
8' 5'
8' 9'
10, 1'
10' 6'
13' 3'
13' 9'
14' 0'
14' 0'
_
S P P
#3
4' 0'
6' 7'
7' 5'
8' 4'
8' e'
9' 11'
10' 4'
13' 1'
13' 7'
14' 0'
14' 0'
U
H
Stud
4' 0'
6' 7'
7' 0'
8' 4'
8' e'
9' 11'
10' 4'
13' 1'
13' 7'
14' 0'
14' 0'
U
Standard
4' 0'
5' 8'
6' 0'
7' 6'
B' 0'
9' 11'
10' 4'
11' 10'
12' 8'
14' 0'
14' 0'
#1
4' 5'
7' 3'
7' 6'
8' 7'
8' 11'
10, 2'
10' 7'
13' 5'
13' 11'
14' 0'
14' 0'
S P
#2
4' 2'
7' 2'
7' 5'
8' 5'
8' 9'
10, 1'
10, 6'
13, 3'
13, 9'
14' 0'
14' 0'
#3
4' 1'
5' 11'
6' 4'
7' 11'
8' 5'
10, 0'
10' 5'
12' 5'
13' 3'
14' 0'
14, 0'
QJ
C
D r L
Stud
4' 1'
5' 11'
6' 4'
7' 11'
8' 5'
10' 0'
10' 5'
12' 5'
13' 3'
14' 0'
14' 0'
Standard
4' 0'
5' 3'
5' 7'
7' 0'
7' 6'
9' 5'
10' 2'
11' 0'
11' 9'
14' 0'
14' 0'
#1 / #2
4' 8'
7' 11'
8' 2'
9' 4'
9' B.
10, 1'
11' 6'
14' 0'
14' 0'
14' 0'
14' 0'
d
_
Sc
P I�
#3
4' 5'
7' 7'
8' 1'
9' 2'
9' 6'
10, 11'
11, 5'
14' 0'
14' 0'
14' 0'
14' 0'
U
LJ P
Stud
4' 5'
7' 7'
8' 1'
9' 2'
9' 6'
10, 11'
11' 5'
14' 0'
14' 0'
14' 0'
14' 0'
U
I�
Standard
4' 5'
6' 6'
6' 11'
8' 8'
9' 3'
10' 11'
11' S'
13' 7'
14' 0'
14' 0'
14' 0'
X
#1
4' 10'
8' 0'
8' 3'
9' 5'
9' 9'
11' 2'
11' 8'
14' 0'
14' 0'
14' 0'
14' 0'
d
S P
#2
4' 8'
7' 11'
8' 2'
9' 4'
9' 8'
11' V
11' 6'
14' 0'
14' 0'
14' 0'
14' 0'
#3
4' 6'
6' 10'
7' 3'
9' 1'
9' 7'
ll' 0'
11' 6'
14' 0'
14' 0'
14' 0'
14' 0'
.--I
[-
D f L
Stud
4' 6'
6' 10'
7' 3'
9' 1'
9' 7'
11' 0'
11' 6'
14' 0'
14' 0'
14' 0'
14' 0'
Standard
4' 5'
6' 1'
6' 5'
8' 1'
8' 7'
10' 11'
11' 5'
12' 8'
13' 7'
14' 0'
14' 0'
Bracing Group Species and Grades+
Group At
S ruce-Pine-Fly, Hen -Fir
#1 / #2 Stnndnrd #2 Stud
#3 1 Stud 1 #3 IStQndardl
Dou ins Fir -Larch Southern Pinemmm
#3 #3
Stud Stud
Standard I Standard
Group Bi
Hen -Fir
#1 & Btr
#1
Douglas Fir -Larch Southern Plnermom
#1 #1
#2 #2
1x4 Braces shall be SRB (Stress -Rated Board).
■wFor lx4 So. Pine use only Industrial 55 or
Industrial 45 Stress -Rated Boards. Group B
values may be used with these grades.
Gable Truss Detail Notes:
Wind Load deflection criterion Is L/240.
Provide uplift connections for 135 plf over
continuous bearing (5 psf TC Dead Load).
Gable end supports load from 4' 0' outlookers
with 2' 0' overhang, or 12' plywood overhang.
Atiaut jt
Attach 'L' braces with 10d (0,128'x3.0' min) nails.
able Truss
)K For (1) 'L' brace+ space nails at 2' o.c.
In IS' end zones and 4' o.c. between zones.
Diagonal brace option-
)K)KFor (2) 'L' braces+ space nails at 3' o.c,
vertical length may be
T
In 18' end zones and 6' o.c, between zones,
doubled when diagonal
18'
)K
'L' bracing must be a minimum of 80X of web
brace Is used. Connect
dlagonnl brace for 690#
•L. L
-�-
1+��i►rrrp
member length.
at each end. Max web
Brace
WA
Gable Verticnl Plate Sizes
total length Is 14'.
h • Ir r%
• •
/� ���
Verticnl Len th No S lice
2x6 DF-L #2 or
I <�
V • •
�p
Less than 4' 0' 2X4
better dlagonnl
r
1I �A
••
Greater than 4' 0', but 4X4
Vertical. Length shown
bracer single
8,
4
#
less than 12' 0'
In table above.
45'
or double cut
(as
L
1
��
shown) at
Iril I
+ Refer to common truss design for
upper end.
ri
npeak,
splice, and heel plates.
Connect diagonal at
• ne
o•' riW seBenring ry ,
'L
C G'Ic
Refer to the Building Designer for conditions
midpoint of vertical web.
Refer to
chart abo
C v
or roa� vQl3tft a
not addressed by this detail.
ovARNDraH READ AND FfLLDV ALL NOTES W THIS DRAVMGI /
�DPCIRTANTww FURNISH THIS DRAVIW TO ALL CONTRACTORS INCLUDING THE DuTALLERs.
fl • Qn1��
`°`
C
REF ASCE7-10-GAB16030
Trusses require extreme care N fabrlcatlnp, handling, shipping, Installing and bracing, Refer to and
follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety
iS 1
� ('T (7 # » • • p s`
/ U [[11
DATE 10�01�14
practices prior to performing these Functions. Installers shall provide temporaryy bracing per BCSL
Unless noted otherwise, top chord shall have attached bottom
jl l
%
DRWG A16030ENC101014
properly structural sheatHYrg and chord
shall have a properly attached Hold ceiling. Locations shown for permanent lateral restraint of webs
shall have bracing Installed BCSI
`ly,
M j
//e1�+'�i111`\1 \
ah
per sections B3, B7 or BIO, as appUcable. Apply plates to each face
of truss and position as shown above and on the Joint Detalis, unless noted otherwise.
P'
Refer to drawings 160A-Z for standard plate positions.
a c
Alpine, division of ITW Building Components Group Inshall not be responsible for any deviation fran
)AX,
AN llW COMPANY
this drawing, any failure to bu0d the truss In conformance with ANSI/TPI 1, or for handling, shipping,
InstWatlen 6 bracing of trusses.
TOT, LD, 60 PSF
A sent on this drawing or cover page Ustkp this drawing, k,dcmtes acceptance of professional
11514\Earth\ Cit \ Expressway
Y y
engineering responsWlty solely for the design shown. The slth abittty and use of this dwg
rn
11 Suite%242
For any structure Is the rasponsWlty of the Bulldhg Designer per ANSUIPI 1 SecP-
%\Earth\City.%MO\63045
For no" Information see this Job's general notes page and these web si
ALPINE+ TPI,
MAX.
SPACING 24,0'
www.alpineltw,conN www.tpinst.orgi SECA, www.sbctndustryargN 100 ww-=WW178.
Yoonhwak Kim FL PE #86367
Gable Stud Reinforcement Detail
ASCE 7-16: 160 mph Wind Speed, 30' Mean Height, Enclosed, Exposure C, Kzt = 1,00
Or, 140 MPH Wind Speed, 30' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00
Ort 140 Mph Wind Speed, 30' Mean Height, Enclosed, Exposure D, Kzt = 1.00
Or, 120 Mph Wind Speed, 30' Mean Height, Partially Enclosed, Exposure D, Kzt = 1.00
S
2x4 Brace
Gable Vertical
Spacing Species Grade
No
Braces
(1) lx4 'L' Brace x
(1) 2x4 'L' Brace x
(2) 2x4 'L' Brace xx
(1) 2x6 'L' Brace x
(2) 2x6 'L' Brace 131
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
#1 / #2
3' 8'
6' 3'
6' 6'
7' 5'
7' 8'
8' 9'
9' 2'
11' 7'
12' 0'
13' 9'
14' 0'
U
Sp
I F
#3
3' 6'
S' 5'
5' 9'
7' 2'
7' 7'
8' 8'
9' 1'
ill 3'
ill 11'
13' 7'
14' 0'
Stud
3' 6'
5' 4'
5' 8'
7' 2'
7' 7'
8' 8'
9' 1'
11' 2'
11' 11'
13' 7'
14' 0'
O
Stnndnrd
3' 6'
4' 7'
4' 11'
6' 2'
6' 7'
8' 4'
B' 11'
9' 8'
10' 4'
13, 1'
14' 0'
#1
3' 10'
6' 4'
6' 7'
7' 6'
7' 9'
8' 11'
9' 3'
11' 9'
12, 2'
13' 11'
14' 0'
J
S P
#2
3' 8'
6' 1'
6' 6'
7' 5'
7' 8'
8' 9'
9' 2'
11' 7'
12, 0'
13' 9'
14' 0'
#3
3' 7'
4' 10'
5' 2'
6' 5'
6' ill
8' 9'
9' 1'
10, 1'
10, 10'
13' 8'
14' 0'
d
DFLI
Stud
3' 7'
4' 10'
5' 2'
6' 5'
6' 11'
8' 9'
9' 1'
10, 1'
10, 10'
13' 8'
14' 0'
Standard
3' 3'
4' 3'
4' 7'
5' 8'
6' 1'
7' 9'
8' 3'
8' ill
9' 7'
12, 2'
13' 0'
U
#1 / #2
4' 2'
7' 2'
7' 5'
8' 5'
8' 9'
10, 1'
10' 6'
13' 3'
13, 9'
14' 0'
14' 0'
_
S P F
#3
4' 0'
6' 7'
7' 5'
8' 4'
8' B'
9' 11'
10, 4'
13, 1'
13' 7'
14' 0'
14' D-
U
LJ [
Stud
4' 0'
6' 7'
7' 0'
8' 4'
8' B'
9' 11'
10' 4'
13' 1'
13' 7'
14' 0'
14' 0'
oi
O
I I
Standard
4' 0'
S' B'
6' 0'
T 6'
8' 0'
9' 11'
10' 4'
11' 10'
12' B'
14' 0'
14' 0'
#1
4' 5'
7' 3'
7' 6'
8' 7'
8' 11'
10, 2'
10' 7'
13' 5'
13, 11'
14' 0'
14' 0'
S P
#2
4' 2'
7' 2'
7' 5'
8' 5'
8' 9'
10, 1'
10' 6'
13' 3'
13' 9'
14' 0'
14' 0'
#3
4' 1'
5' 11'
6' 4'
7' 11'
8' 5'
10' 0'
10' 5'
12' 5'
13' 3'
14' 0'
14' 0'
0)
D F L
Stud
4' 1'
5' 11'
V 4'
7' 11'
8' 5'
10, 0'
10' 5'
12' 5'
13' 3'
14' 0'
14' 0'
Standard
4' 0'
5' 3'
5' 7'
7' 0'
7' 6'
9' 5'
10' 2'
ill 0'
11' 9'
14' 0'
14' 0'
0
#1 / #2
4' 8'
7' 11'
e' 2'
9' 4'
9' 8'
10, 1'
11' 6'
14' 0'
14' 0'
14' 0'
14' 0'
d
S P F
#3
4' 5'
7' 7'
8' 1'
9' 2'
9' 6'
10, ill
11' 5'
14' 0'
14' 0'
14' 0'
14' 0'
U
I I F
Stud
4' 5'
7' 7'
8' 1'
9' 2'
9' 6'
10, 11'
11' 5'
14' 0'
14' 0'
14' 0'
14' 0'
O
I�I
Standard
4' 5'
6' 6'
6' 11'
B' 8'
9' 3'
10' 11'
11' 5'
13' 7'
14' 0'
14' 0'
14' 0'
X
#1
4' 10'
8' 0'
8' 3'
9' 5'
9' 9'
11' 2'
11' 8'
14' 0'
14' 0'
14' 0'
14' 0'
d
S P
#2
4' 8'
7' 11'
8' 2'
9' 4'
9' 8'
ill 1'
11' 6'
14' 0'
14' 0'
14' 0'
14' 0'
#3
4' 6'
6' 10'
7' 3'
9' 1'
9' 7'
11' 0'
11' 6'
14' 0'
14' 0'
14' 0'
14' 0'
r-I
D F L
Stud
4' 6'
6' 10'
7' 3'
9' 1'
9' 7'
11' 0'
ill 6'
14' 0'
14' 0'
14' 0'
144 0'
Standard
4' 5'
6' 1'
6' 5'
8' 1'
8' 7'
10, 11'
11' 5'
12' 8
13' 7'
14' 0'
14' 0'
Bracing Group Species and Grades,
Group AI
S ruce-Pine-Fir Hem-Flr
Stnndnrd #2 Stud
#3 Stud #3 Stnndnrd
Dou las Fir -Larch Southern Plnewww
#3 i
Stud Stud
Standard Standard
Group Bi
Hen -Fir
#1 & Btr
#1
Dou Ins Flr-Lurch Southern Plnewww
#1 #1
#z 1 #2
lx4 Braces shall be SRB (Stress -Rated Board),
wwFor lx4 So. Pine use only Industrial 55 or
Industrial 45 Stress -Rated Boards, Group B
values ma be used with these rndes.
Gable Truss Detail Notes:
Wind Load deflection criterion Is L/240.
Provide uplift connections for 135 plf over
continuous bearing (5 psf TC Dead Load).
Gable end supports toad from 4' 0' outlookers
with 2' 0' overhang, or 12' plywood overhang.
About
j�
Attach 'L' braces with IOd (0,128'x3.0' min) nalls,
able Truss
)K For (1) 'L' braces space nails at 2' o.c.
In Is' end zones and 4' o,c, between zones.
Diagonal brace options
)K)KFor (2) 'L' bracesi space nails at 3' o,c,
vertical length may be
In 18' end zones and 6' o.c, between zones.
doubled when diagonal
18'
'L' bracing must be a minimum of 80X of web
brace is used. Connect
L
1Q4�,� fffff
member length.
diagonal brace for 690#
at each end. Max web
'L'
Wqx' P10.
Gable Vertical Plate Sizes
total length Is 14'.
Brace End
Zones, typ,
�:
54/t
Vertical
Q • ` / r/
��
Len th No S lice
2x6 DF-L #2 or
"r'
e�
, �p
Less than 4' 0' 2X4
better diagonal
yA
xo
Greater than 4' 0', but 4X4
Vertical length shown
brace: single
8,
�4
s
less than 12' 0'
In table above.
45'
or double cut
I
L
(as shown) at
+ Refer to common truss design for
upper end.
peak, splice, and heel plates.
Connect diagonal at
on s Bearing
Refer to the Building Designer for conditions
midpoint of vertical web.
Refer to
chart abo
t� Fca •a
o Ma vlaiftl
not addressed by this detail.
"WARNIN(iilm READ AND FOi OV ALL NOTES ON THIS DRAVDU '�
oD�(TANTww FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS �i
.<` s 0 " ���
0 . C OR10�:
REF ASCE7-16-GAB16030
Trusses require extreme care In fabricating, hand(ing, shipping, Installing and bracing. Refer to and
follow the latest edition of BCSI (BuRding Component Safety Information, by TPI and SBCA) for safety
A ®e 0 ��
A l? (�
DATE O1/26/2018
practices prior to performing these functions. Installers shall provide temporaryy bracing per BCSL
Unless anted otherwise, top chord shall have bottom
d� /f�AI�� 1�
DRWG A16030ENC160118
properly attached structural shenthtno and chord
shall have a properly attached rigid ce0.ing. Locations shown for permanent lateral restraint of webs
shall have bracing Installed BCSI B31B7
`V W]Vf
per sections or B10, as applkabte. Apply plates to each face
of truss and position as shown above and on the Joint Details, unless noted otherwise.
�I
Refer to drawings 160A-Z for standard plate positions.
Alpine, a division of ITV Building Components Group Inc shall not be responsible for anyy deviation from
AN TTW COMPANY
this drawing, any fallure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping,
Installation & bracing of trusses.
AX,
TAT, LDr 60 PSF
A seal on this drawing or cover page Usting this drawing, Indicates acceptance of professional
\ \ 514\Earth Cil \ Expressway
Y P y
englnecring responsWFty solely for the design shown The suitability and use of this drawing
11 Suite\242
far any structure Is the respons6Nty of the Building Designer per ANSI/TPI 1 Sec2.
\ \ Earth\ City,\ MO\ 63045
For no" information see this Job's general notes page and these web
ALPINEe www.alpineltw.com) TPIi www.tpinst.org) SBCA www.sbclndustry.org) ICG ,uw.l
MAX,
SPACING 24,0'
'T
Relnfol
Memb
Go
Tr
Gable Detail
Fnr I Pt -in \/PI -tarn 1 4_-
Gable Truss Plate
pproprlate Alpine gable detail for
e sizes for vertical studs,
Engineered truss design for peak,
,b, and heel plates.
vertical plates overlap, use a
.te that covers the total area of
lapped plates to span the web.
el 2*2X4
4 2X8
Provide connections for uplift specified on the engineered truss design.
Attach each 'T' reinforcing member with
End Driven Nails[
10d Common (0.148'x 3,',min) Nails at 4' o,c. plus
(4) nails In the top and bottom chords,
Toenalled NQI1si
IOd Common (0.148'x3',min) Toenails at 4' o,c. plus
(4) toenails In the top and bottom chords.
This detail to be used with the appropriate Alpine gable detail for ASCE
wind load,
ASCE 7-05 Gable Detail Drawings
A13015051014, A12015051014, A11015051014, A10015051014, A14015051014,
A13030051014, A12030051014, A11030051014, A10030051014, A14030051014
ASCE 7-10 8 ASCE 7-16 Gable Detail Drawings f
A11515ENC100118, A12015ENC100118, A14015ENC100118,
A18015ENC100118, A20015ENC100118, A20015END1001 0 ryr
A11530ENC100118, A12030ENC100118, A14030ENC1�� 0
A18030ENC100118, A20030ENC100118, A20030ENI{T01l� A�0 3 61�11�?�C`�al
S11515ENC100118, S12015ENC100118, S14015EN 0118,A6 bl�l
S18015ENC100118, S20015ENC100118, S20015Ep�10011% S 0 15P 1 8
•
S11530ENC100118, S12030ENC100118, S14030EMC1001VS, Saw 7 p
S18030ENC100118, S20030ENC100118, S20030&N]yp0118, S20030PED100118 8
Tl T>
See appropriate Alpine gable detail for maximum unrwInforced'6*e Vertical lgi
-WARNIIG- READ AND FILLDW ALL NOTES UN THIS DRAWM VO
-I PORTANTww FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDB�i THE INSTALLERS. di
Trusses require extreme care In fabricating, handUng, shipping, InstalUng and bracng. Refer to and
folio. the latest edition of BCSI (Bullring Component Safety Information, by TPI and SBCA) for safety
practices prior to performing these functions. Installers shall provide temporary bracing per BCSL
Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom cho
shall have a properly attached rigid ceRing. Locations shorn for permanent lateral restraint of web!
shall have bracing Installed per BCSI sections B3, B7 or BID, as applicable. Apply plates to each face
of truss anal position as shown above and on the Joint Detalls, unless noted otherwise.
PI Refer to drawings 16CA-Z for standard plate positions.
Alpine, a divislaInc.n of ITV Building Components Group Inshall not be responsible for any deviation fr
this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping,
AN ITW COMPANY Installation R bracing of trusses.
A seal on this drowing or cover page UstkQ this drawing, Fwlcates acceptance of professional
11
514N Earth\ City\ Expressway engineering responsibility solely for the design shown. The sultablUty and use of this dmwkV
\ \ Suite\ 242 for any structure Is the responsU ty of the Bu &v Designer per ANSI/TPI 1 Sec2. /
\ \ Earth\ City.\ MO\ 63045 For ncre Information see this Job's general notes page and these web - ow
ALPINFu ww.alpineltw.coni TPD www.tpinstorgl SBCA, ww.sbclndustryargi ICO wwdctsaf
-Aa q ATE OF
T 0 0 • 0 ® 0
"' jiii��4 i'0
e
Yoonhwak Kim, FL PE #86367
'T' Reinforcement Attachment Detail
'T' Reinforcing 'T' Reinforcing
Member Member
Toe-nall - Or - End-nall
To convert from 'L' to 'T' reinforcing members,
multiply 'T' Increase by length (based on
appropriate Alpine gable detail).
Maximum allowable 'T' reinforced gable vertical
length Is 14' from top to bottom chord.
'T' reinforcing member material must match size,
specie, and grade of the 'L' reinforcing member,
✓eb Length Increase w/ 'T' Brace
'T' Relnf.
Mbr, Size
'T'
Increase
2x4
30 X
2x6
20 X
Example
ASCE 7-10 Wind Speed = 120 mph
Mean Roof Height = 30 ft, Kzt = 1.00
Gable Vertical = 24'o.c. SP #3
'T' Reinforcing Member Size = 2x4
'T' Brace Increase (From Above) = 307 = 1.30
(1) 2x4 'L' Brace Length = 8' 7'
Maximum 'T' Reinforced Gable Vertical Length
1.30 x 8' 7' = 11' 2'
TOT. LD. 60 PSF
FAC, ANY
SPACING 24.0'
F LET -IN VERT
TE 01/02/2018
WG GBLLETIN0118
0 0
I VALLEY FRAMING & BRACING DETAIL
R
BC
t/2
01
Lumber Size and Grade Minumum Requirements
GENERAL NOTES
Purlins required T-0" O.C. in absence of plywood sheathing.
Trusses without sheathing applied must be evaluated accordingly.
Purlins should overlap sheathing one truss spacing minimum.
In cases that this is Impractical, overlap sheathing a minimum
of 6", and nail upwards through sheathing into purlin with a
minimum of 8-8d (0.131"x2.5") common wire nails.
Effects of not providing sheathing below a valley set
must be evaluated by the building designer.
This drawing applies to valleys with the following conditions:
Spans (distance between heels) 40'-0" or less
-Maximum valley height: 14'-0"
-Maximum mean roof height: 30 feet
-ASCE 7-05,140 mph, Enclosed, Cat II, Exp B,1=1.0, Kzt=1.0
-Or A Maximum of ASCE 7-10,180 mph, Enclosed, Exp D, Kzt=1.0
TRUSS
TRUSS UNDER VALLEY FRAMING
VALLEY RAFTER OR RIDGE
® +CRIPPLE
ripples 4'-0" for 30 psf (TL) and 20 psf (TD) Max.
ce the crippes for each row starting from the valleys or sleepers
working inward to the ridge board so that cripple locations are
gered between rows.
(TYp)
innection Requirement Notes
2x6 rafters to ridge
4 16d toe -nails
Cripple to ridge
416d toe -nails
Cripple to rafter
416d toe -nails
(••) 816d face -nails
Rafter to sleeper or blocking
516d toe -nails
Rafter to two 2x6 sleepers
416d toe -nails
Sleeper to truss
416d toe -nails
Two 2x6 sleepers to truss
316d toe -nails each sleeper & truss
Ridge board to roof block
416d toe -nails
Ridge board to truss
416d toe -nails
Puriin to (Typ)
316d toe -nails
Truss to blocking
4 16d toe -nails
Truss to cripple
416d toe -nails
Truss to cripple
416d toe -nails
Cripple to purlin
316d toe -nails
tl%w r n-urncu rr an.ccrcrta AKM ubeul 13. Collar beam to rafter 416d toe -nails
CRIPPLE, BRACING, & BLOCKING NOTES NOTE: 16d (0.162"x3.5") COMMON NAILS
-2x4 continuous lateral restraint (CLR) min. is required for cripples 5'-0" to 10'-0" long
nailed w/ 2 -10d (0.148"x3") nails. Or 2x4 "T" or scab reinforcement nailed to flat edge
of crippee with 10d 40.128"x3.0") nails at 6" o.c. "T" or scab must be 90 % of cripple length.
Cripplles over 10'-0' long requre two CLR's or both faces wf "T'. or scab. Use stress
graded lumber & box or common nails.
cNarrow edge of cripple can face ridge or rafter,
as long as the proper number of nails are
Installed Into ridge board
-Install blocking under rafter if sleepers are not used.
-Install blocking under cripples If cripples fall between
lower truss top chords and lateral bracing is not used.
Apply all nailing in accordance to current NDSrwise.eme otherwise.
He
Nails are common wire nails unless noted otherwise.
��`'•v�GENSF''• C�
� Smarr i
BMARNmKb- READ NO FOLLW ALL NOTES DTI TWS MAVDIi S •-• - - - •
on• Talro Ft1RMSH THIS BMWM TO ALL @nRACTuts +NIM rDUNG THE =TALLBRS. * • * C LL 20 30 40 54 REF VALLEY FRAMING
Trusses ngulre extrene can In fabrlcatkg, handling, sWppkg, Instaltky and bracip ' Refer 64
fellow the latest edition of BCSI (BuRdkp Uwan•nt Safety Lrformatlon, by TP1 and SBCA) for di&y T T j C DL 10 20 7 7 DATE 10/01/14
prints net
pN.r to perfomkp these functions. Installers shalt Provide tenporry bndnG. per B STATE 1 1= f1i •
lHess rood oth-Ise, top chord shall have property attached structa j sheatHnG and bettat'cMM��tt p 1 //'"`111 O : Er413C
BC DL 0 0 0 0 DRWG VACNV1801015
., shall have a properly attached rlyd ceiling. Locations shown for pernanent lateral restraint of'.irett�7 0 • I._.
shall have brackp kutalled per BCSI senor B3, 27 r B10, as applicable. Apply plates to each F¢cc j • �V of truss and osttlon as shorn above and m the Joint Detals, unless noted otherle. '', o�a'�,4OR10LL o 0 0 0
Refer to drawYgs 160A-Z for standard plate posltlons. ,o ® •
Alpine, a division of ITV Bulldlno Components rroup L,a shalt not be responsible for any deviation f 0••.a•..jta•• ,4 TOT. LD.30 50 47 61
ANrl"WOOMRAMf this darkq, any �nreof fro bbusjthe
arras kn conformance with ANSLTPI 1, or fr hwwUV, shIppiny oI (�,O�l`�
f�l.seet ontion ;Z drarNtis fvo�r—cov;r trPthe bs o this ha- okili, Indicates f y a.�d u tHstanc,& of �drvrk�ip� ,�f "rA f Y notn`Ni` �t DUR. FAC. 1.25/1.15
13389 Lakefront Drive any heresponsibility ].*, D• � I I Sect'
EaM City, MO 63045 For mare - see this job's General. notes page and these web sites. (� 2 C'� SPACING SEE ABOVE
AIPM rrralpinrrr elt-onl TPI. tpi storpl SBwndrd CA, sbuICO stry V rrr.hczafeap