Loading...
HomeMy WebLinkAboutSTRUCTURAL PERFORMANCE CERTIFICATION REPORTDocument Title: Doc No: FRM B1-02 Structural Performance Certification Authorization Report Rev No: 7 Page: 1 Of: 1 Required By: PRO B1-03 This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review, and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in accordance with the specified referenced standard. Actual fenestration product performance may vary based on many factors, including installation, condition of the wall/roof substrate and the age of the product and installation components. This report indicates the product is eligible for the application of Keystone Certification Program certification labels. Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen evaluated and documented for certification authorization. Only products bearing such a certification label shall be considered certified. The information in this report can be verified at www.keystonecerts.com. 622 -107.0 12/29/2016 6/6/2023 622 CAR & Product ID Number: Issue Date: Expiration Date: Company Code: Licensee Information: Product Information: Model:176 HVHZ Vertical/Horizontal Mullion Operator Type:Mull Max Width:See Table Max Height:See Table Referenced Standard: Product Rating: AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings Config:No Reinforcement Qualifying Test Information: Test Report No:NCTL-210-4032-1 Test Report Expiration:6/6/2023 Authorized Signature:Keystone Certifications, Inc. 145 Limekiln Rd. Suite 100B New Cumberland, Pennsylvania 17070 Phone: 717-932-8500 Fax: 717-932-8501 Revision Date:5/27/2020 Eastern Architectural Systems 16341 Domestic Ave Fort Myers, FL 33912 USA www.keystonecerts.com       Appendix 1 CAR No: 622‐107.0 Expiration Date: 06/06/2023  Keystone Certifications, Inc. New Cumberland, PA 17070 145 Limekiln Rd, Suite 100B  Phone: 717.932.8500  www.keystonecerts.com Eastern Architectural Systems  10030 Bavaria Road  Fort Myers, FL 33913  Load Tables for the:  176 HVHZ Vertical/Horizontal Mullion  DESIGN PRESSURE RATING (psf)  (Design pressures are positive and negative)  Mullion  span (in)  Tributary width (in)  24.00 30.00 36.00 42.00 48.00 54.00 60.00 66.00 72.00  36.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0  42.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0  48.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0  54.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0  60.00 150.0 150.0 150.0 137.7 128.1 122.7 120.9 120.9 120.9  66.00 150.0 143.1 123.3 110.0 101.1 95.3 92.0 90.9 90.9  72.00 145.4 118.9 101.8 90.2 82.2 76.6 72.9 70.7 70.0  78.00 123.2 100.4 85.6 75.4 68.2 63.1 59.4 57.0 55.5  84.00 105.7 85.9 73.0 64.1 57.7 53.0 49.6 47.1 45.4  90.00 91.8 74.4 63.1 55.2 49.5 45.2 42.1 39.7 38.0  96.00 80.4 65.1 55.1 48.1 42.9 39.1 36.2 34.0 32.3  102.00 71.1 57.5 48.5 42.2 37.7 34.2 31.5 29.5 27.9  108.00 63.3 51.1 43.1 37.4 33.3 30.2 27.7 25.8 24.3  114.00 54.2 43.8 36.9 32.1 28.6 25.9 23.9 22.2 21.0  120.00 46.4 37.4 31.5 27.4 24.3 22.0 20.2 18.8 17.7  Impact Ratings  PA/TAS 201/203 – Large and Small Missile Impact Rated Up to Wind Zone 4 and HVHZ