HomeMy WebLinkAboutSTRUCTURAL PERFORMANCE CERTIFICATION REPORTDocument Title: Doc No: FRM B1-02
Structural Performance
Certification
Authorization Report
Rev No: 7 Page: 1 Of: 1
Required By: PRO B1-03
This Certification Authorization Report (CAR) is issued by Keystone Certifications, Inc. (KCI) after full validation review,
and is based on a standardized evaluation of the product conducted by an independent accredited laboratory in
accordance with the specified referenced standard. Actual fenestration product performance may vary based on many
factors, including installation, condition of the wall/roof substrate and the age of the product and installation
components.
This report indicates the product is eligible for the application of Keystone Certification Program certification labels.
Licensee stipulates in affixing certification labels to products, that those products are representative of the specimen
evaluated and documented for certification authorization. Only products bearing such a certification label shall be
considered certified. The information in this report can be verified at www.keystonecerts.com.
622 -107.0
12/29/2016
6/6/2023
622
CAR & Product ID Number:
Issue Date:
Expiration Date:
Company Code:
Licensee Information: Product Information:
Model:176 HVHZ Vertical/Horizontal Mullion
Operator Type:Mull
Max Width:See Table
Max Height:See Table
Referenced Standard: Product Rating:
AAMA 450-10 & PA/TAS 201/202/203 See Appendix 1 Load Tables and Impact Ratings
Config:No Reinforcement
Qualifying Test Information:
Test Report No:NCTL-210-4032-1
Test Report Expiration:6/6/2023
Authorized Signature:Keystone Certifications, Inc.
145 Limekiln Rd. Suite 100B
New Cumberland, Pennsylvania 17070
Phone: 717-932-8500
Fax: 717-932-8501
Revision Date:5/27/2020
Eastern Architectural Systems
16341 Domestic Ave
Fort Myers, FL 33912
USA
www.keystonecerts.com
Appendix 1 CAR No: 622‐107.0
Expiration Date: 06/06/2023
Keystone Certifications, Inc. New Cumberland, PA 17070 145 Limekiln Rd, Suite 100B
Phone: 717.932.8500
www.keystonecerts.com
Eastern Architectural Systems
10030 Bavaria Road
Fort Myers, FL 33913
Load Tables for the:
176 HVHZ Vertical/Horizontal Mullion
DESIGN PRESSURE RATING (psf)
(Design pressures are positive and negative)
Mullion
span (in)
Tributary width (in)
24.00 30.00 36.00 42.00 48.00 54.00 60.00 66.00 72.00
36.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0
42.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0
48.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0
54.00 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0 150.0
60.00 150.0 150.0 150.0 137.7 128.1 122.7 120.9 120.9 120.9
66.00 150.0 143.1 123.3 110.0 101.1 95.3 92.0 90.9 90.9
72.00 145.4 118.9 101.8 90.2 82.2 76.6 72.9 70.7 70.0
78.00 123.2 100.4 85.6 75.4 68.2 63.1 59.4 57.0 55.5
84.00 105.7 85.9 73.0 64.1 57.7 53.0 49.6 47.1 45.4
90.00 91.8 74.4 63.1 55.2 49.5 45.2 42.1 39.7 38.0
96.00 80.4 65.1 55.1 48.1 42.9 39.1 36.2 34.0 32.3
102.00 71.1 57.5 48.5 42.2 37.7 34.2 31.5 29.5 27.9
108.00 63.3 51.1 43.1 37.4 33.3 30.2 27.7 25.8 24.3
114.00 54.2 43.8 36.9 32.1 28.6 25.9 23.9 22.2 21.0
120.00 46.4 37.4 31.5 27.4 24.3 22.0 20.2 18.8 17.7
Impact Ratings
PA/TAS 201/203 – Large and Small Missile Impact Rated Up to Wind Zone 4 and HVHZ