ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Low Slope Application
Prescriptive BUR-RAS 150
Asphaltic Shingles
Concrete or Clay Tile
Metal Roofs
Wood Shingles and
Shakes
Other
Required Sections of
the Permit Application
Form
A, B, C
A, B, C
A, 8, D
A,B,D,E
A, B, ❑
A, B, D
As Applicable
Attachments Required
See List Below
1,2,3,4A6,7
t,4,5,6,7
1,2.4,5r8,7
1,2,3,4,5,6,7
1,2,3,4,50,7
t,2,4A6,7
I,2,3.4,5,6,7
ATTACHMENTS REQUIRED As Applicable):
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4. Other Component of Product Approval
5. Municipal Permit Application
6. Owners Notification for Roofing Considerations (Reroofing Only)
7. Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
'" LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval No.:
Design Wind Pressures, From RAS 128 Or Calculations. -
Zone V: _ Zone 1: Zone 2: Zone 3:
Max. Design Pressure, from the specific product approval
system:
Deck:
Type:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Banding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Sanding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':—"
oc @ Lap, # Rows
@ "ao
Zone 1:—"
❑c @ Lap, # Rows
@ Doc
Zone 2:_,_."
oc @ Lap, # Rows
@ moo
Zone 3:—"
oc @ Lap, # Rows
@ "oc
Number of Fasteners Per Insulation Board:
Zone 1': Zane 1: Zone 2: Zone 3
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16.
ST. LUC E WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: JA TAYLOR ROOFING EDGE-LOC 1" STANDING SEAM
Notice of Acceptance Number: N0A:18-1023.17
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1: -57 Zone 2e:-57 Zone 2n -91 Zone 2r: -91 Zone 3e: -91 Zone 3r: -128
Deck Type: i PLYWOOD
Roof $iope: Type Underlayment: ELF ApHEREp UNaERLAYMEiJT To POLYGLASS MTs FL#5259.1
insulation:
Fire Barrier:
Ridge Ventilation? Fastener Type & Spacing: Fj�F EL�14- ERIMETER, 8❑ RING S NK NAILS
Adhesive Type:
Type Cap Sheet:
[!!an Roof Height: 15' FT Roof Covering: METAL
Type R Size Drip 2" x 2 112"
Edge:
ST. LUCIE WORKS
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mf. If the Mf values
are greater than or equal to the Mrvalues, for each area of the roof, then the rile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: x h � Md Product Approval ML-
(Zone 2e: _ X. = ---) - Mg: = M,,�* Product Approval Mr
(Zone 2n: x X - Mg; = Product Approval Mf
(Zone 2r: x 7L = j - Mg: = Me, Product Approval Mf
(Zone 3e: x 76 = - Mg: - Mr& Product Approval Mt
(zone 3r: x - Mg'. -- Mar ar Product Approval Mf_
Method 2 "Slmplified Tile Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below Product Approval Mf
Mr required Moment Resistance*
Mean Roof Height Roof Slope
2:12
3:12
4:12
5:12
6:12
1s,
34.4
32.2
30.4
28.4
26.4
2D'
36.5
34.4
32.2
30.1
28.0
25'
38.2
36.0
33.8
31.6
29.4
3d
39.7
37.4
35.1
32.8
30.5
40'
42.2
39.8
37.3
34.9
32,4
7:12
24.4
25.9
z7.1
28.2
30.0
*Must be used in conjunction with
a list of moment based tile systems
■ For Uplift based tile systems use Method 3. Compare the values for F'
with the values for F, If the F' values are greater than or
equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations
Per RAS 12T
(zone 1: x L =x W:= j -W: cos r =Fr1
Product Approval F'
(Zone 2e: x L =x W:=�� -W.-cos r =F,2e
Prod u ct Ap p rova I F'
(Zone 2n: x I =x W:=:� -W; cos r =Fr2"
Product Approval F'
(Zone 2r: x L =x W:= ) -W: cos r =Fr2r
Product Approval F'
(Zone 3e: x (-= x W:= 7 -W: cos r =Fr3e
Product Approval F'
(Zone 3r: x L =x W:= ) -W: cos r =Fr3r
Product Approval F'