HomeMy WebLinkAboutPROJECT INFORMATION2'-8"10'-10" Certification Number: AR 17155 Date: 8/21/21 Name: Dan Stuart Davis, Architect Product Product Approval Submittal Affidavit (PAA) ManufacturerModel # 49.7 160 MPH (ult) WIND SPEED PER FBC R301.2(2), EXPOSURE ‘B’ 6d GALV COMMON OR #8x1-1/2" GALV WOOD SCREWS @ 6"oc ON 1 2" PLY ON WOOD STUDS @ 16"oc JAMES HARDIE CO.5 16" HARDIEPANELEXTERIOR SIDING Z5, 10SF +24.3/-32.5 FLOOR PLAN SCALE 1/4" = 1'-0" WALL SECTION SCALE 1" = 1'-0"ELEVATIONFLOOR PLAN1 DESIGN PARAMETERSDETAILSBuilding Design Pressure (PSF) Product Design Pressure (PSF) Attachment Method Type, Size, Spacing, & Embedment DAN STUART DAVIS, ARCHITECTPROJ: 2115 DWN: DSDDATE: 8/19/21 CHK: DSD36 Tuckaway Ct.Henderson, NV 89074Tel: 772-979-3380E-mail: dan.dsd@gmail.comFRAME WALL DETAIL479 SANDIA AVE.,PORT ST. LUCIE, FL 34952HARDIE BD TYVEK 1 2" PLY SHTG STUD ENLARGED DETAIL PROJECT INFORMATION 10'-0" EXIST +/-0.18Internal Pressure Coefficient: OCCUPANCY: EXISTING CONSTRUCTION: Int walls - wood stds & drywall Ext. bearing walls - CBS & wood studs Unprotected, Unsprinklered R3 One-Family Residence Wood trusses Type V Building Mean Height: DESIGN PARAMETERS: Building Design: AREA TABULATIONS: No Change 160 mph 3 sec. gust IIRisk Category: Roof Overhang:24" Roof Pitch:2/12 Membrane Roofing Enclosed 2020 7th Ed. Florida Residential & Existing Building Codes, Repair GENERAL SCOPE OF WORK: GENERAL NOTES: 1. SCOPE OF WORK INCLUDES: a) REMOVE ALL ROTTED STUDS OR WALL PLATES REPLACE WITH NEW. USE P.T. AT BASE PLATE. b) INSTALL ALL ANCHOR HARDWARE AS DETAILED, SIMPSON OR EQ. c) INSTALL INSULATION, PLYWOOD SHEATHING, TYVEK AND HARDIE BD. SIDING. d) SEAL JOINTS AND ALL EDGES OF HARDIE BD. e) PAINT EXTERIOR WITH EXTERIOR GRADE LATEX PAINT 1. THIS PROJECT REPAIRS A ROT DAMAGED FRAME WALL FILLS IN AT AN ORIGINAL DOUBLE WINDOW. 2. ANCHORAGE IS PROVIDED FROM TRUSSES TO FOUNDATION SLAB. 3. PER FBC, EXISTING 2020 7th ED., 406.2.1, THE ROTTED STRUCTURAL ELEMENTS (STUDS & PLATES) HAVE NOT CAUSED SUBSTANTIAL STRUCTURAL DAMAGE AND HAVE BEEN REPLACED LIKE FOR LIKE. STRAPS ARE BEING ADDED TO STRENGHTEN THE WALL BEYOND IT'S ORIGINAL DESIGN. 4. HARDIE BOARD SIDING SHALL BE PER FL 13233-R6, 5 16" THK 'HARDIEPANEL', SEE PAA. 5. CONFORM TO THE REQUIREMENTS OF THE ST. LUCIE COUNTY BUILDING DEPARTMENT. PLATE TO TRUSS CONN. 1-1/2" SCALE 8'' TIMBERLOK SCREW @ EACH TRUSS EXISTING ELEC OUTLETS VERIFY LOCATION AND SERVICIBILITY PREVIOUS ROTTED WINDOW REPLACED WITH NEW STUDS REBUILT FRAME WALL PER DETAILS AND NOTES - 8/21/21 CLIENT REVIEW- 8/23/21 PERMIT APPLICATIONSignature: I have reviewed the above product approval information and approved it. CERTIFICATION OF UN-PERMITTED WORK THE REPAIR WORK SHOWN ON THIS DRAWING HAS BEEN INSPECTED AND APPROVED ACCORDING TO THE FLORIDA BUILDING CODE - RESIDENTIAL - EXISTING 2020, 7th ED. FOR STRUCTURAL, ARCHITECTURAL, AND ELECTRICAL BY DAN S. DAVIS, FL 17155 AND SEALED ON THIS TITLE BLOCK SHEET. DocuSign Envelope ID: E31B25CD-3712-4C46-8854-BF40C945002C 8/23/2021