UES Project No: 3360.1800067.0000
Workorder No: 242806-1
Report Date: 08/25/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In -Place Density Test Report
Client: D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician: Mark Rogers
1430 Culver Drive, NE Date Tested: 08/17/2021
Palm Bay, FL 32907
Project: CMT CREEKSIDE
Yorktown Drive & Okeechobee Road,Fort Pierce, St Lucie County, FL
Area Tested: Lot 30 / 3416 Trinity Cir, Fort Pierce, FL
Material: Backfill
Reference Datum: 0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Type of Test:
Field: ASTM D-6938 Nuclear Gauge Method
Laboratory: ASTM D1557 Modified Proctor
Maximum
Optimum
Field Dry
Field
Soil
Pass
Test
Density
Moisture
Density
Moisture
Compaction
or
No.
Location of Test
Range
(pcf)
(%)
(pcf)
(%)
(%)
Fail
1
Northeast corner of lot
0-1 ft
118.6
10.8
114.3
9.7
96
Pass
2
Southwest corner of lot
0-1 ft
118.6
10.8
115.6
9.7
97
Pass
3
Center of lot
0-1 ft
118.6
10.8
115.4
10.0
97
Pass
Remarks
Permit: 2105-0815
The in -place density tests were performed within the foundation/
building pad footprint of the referenced residential lot. The test
results either meet or exceed the requirements of the FHA/HUD
manual and the current edition of the Florida Building Code for
soil compaction. The Contractor is responsible for maintaining
the tested soil sub grade in the same condition that existed at
the time UES performed the referenced density tests. UES is not
responsible if the tested area is altered from the approved
condition at the time of testing.
Reviewed By
GFA International, Inc
FBPE Registry No.4930
N. p84146
�O STATE OF [/
%SS/�NA� fit,`•
Digitally signed by Thomas D
Montano:A0141 0000000178
18498DCD000019A3
Date: 2021.08.2 5 12:18:11
-04'00'
Thomas Dominic Montano
Branch Manager
STATE OF FLORIDA
Professional Engineer No. 84146
This item has been digitally signed and sealed by Thomas Dominic
Montano on the date adjacent to the seal. Printed copies of this
document are not considered signed and sealed and the signature
must be verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1