HomeMy WebLinkAboutTindal letter6904 Parke East Blvd. Tampa, FL 33610-4115 MiTek USA, Inc. RE: 2463982 - Design Code: FBC2020/TPI2014 Wind Code: N/A Wind Speed: 160 mph Roof Load: 40.0 psf Design Program: MiTek 20/20 8.4 1 of 2 This package includes 65 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Floor Load: N/A psf Site Information: Lot/Block: . Customer Info: Christy Tindall Project Name: Tindall Residence Model: . Subdivision: . Address: ., . State: FLCity: Fort Pierce Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: January 6,2021 Finn, Walter The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource-Jacksonville. Truss Design Engineer's Name: Finn, Walter My license renewal date for the state of Florida is February 28, 2021. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. No. Seal# Truss Name 1 T22355098 PB1 Date 1/6/21 2 T22355099 PB2 1/6/21 3 T22355100 PB3 1/6/21 4 T22355101 PB4 1/6/21 5 T22355102 RF01 1/6/21 6 T22355103 RF02 1/6/21 7 T22355104 RF03 1/6/21 8 T22355105 RF04 1/6/21 9 T22355106 RF05 1/6/21 10 T22355107 RF06 1/6/21 11 T22355108 RF07 1/6/21 12 T22355109 RF08 1/6/21 13 T22355110 RF09 1/6/21 14 T22355111 RF10 1/6/21 15 T22355112 RF11 1/6/21 16 T22355113 RF12 1/6/21 17 T22355114 RF13 1/6/21 18 T22355115 RF14 1/6/21 19 T22355116 RF15 1/6/21 20 T22355117 RF16 1/6/21 21 T22355118 RF17 1/6/21 22 T22355119 RF18 1/6/21 No. Seal# Truss Name 23 T22355120 RF19 Date 1/6/21 24 T22355121 RF20 1/6/21 25 T22355122 RF21 1/6/21 26 T22355123 RF22 1/6/21 27 T22355124 RF23 1/6/21 28 T22355125 RF24 1/6/21 29 T22355126 RF25 1/6/21 30 T22355127 RF26 1/6/21 31 T22355128 RF27 1/6/21 32 T22355129 RF28 1/6/21 33 T22355130 RF29 1/6/21 34 T22355131 RF30 1/6/21 35 T22355132 RF31 1/6/21 36 T22355133 RF32 1/6/21 37 T22355134 RF33 1/6/21 38 T22355135 RF34 1/6/21 39 T22355136 RF35 1/6/21 40 T22355137 RF36 1/6/21 41 T22355138 RF37 1/6/21 42 T22355139 V1 1/6/21 43 T22355140 V2 1/6/21 44 T22355141 V3 1/6/21 To Whom It May Concern: The V24 truss was eliminated at time of truss erection because of field conditions. The Space between V24 and RF05 is less than 30". Due to the fact that there is additional loading applied to the RF05 Girder Truss and that the span rating of 19/32 structural roof sheathing is 30" no additional bracing or repairs are necessary to the truss system. August 24th, 2021 Sincerely, Walter P. Finn