APPLICANT: Brian & Susan Young
AGENT: Cooper Enterprises 4.0, LLC
PROPERTY ADDRESS: 4900 Seagrape Dr Fort Pierce, FL 34982
LOT: 8 BLOCK: 42
SUBDIVISION: Indian River Estates ID#: 3402-608-0124-000-4
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ] [01] TANK SIZE [1] 1090.00 [21 [
] [271
SURFACE WATER FT
[ ] [021 TANK MATERIAL Polypropylene [
] [281
DITCHES 19 FT
[ ] [031 OUTLET DEVICE [
] [291
PRIVATE WELLS FT
[ ] [04] MULTI -CHAMBERED [LZJ N ] (
] [30]
PUBLIC WELLS FT
[ ] [051 OUTLET FILTER Polylok PL-68 [
] [31]
IRRIGATION WELLS FT
[ ] [06] LEGEND 1. 70-143-11DC4 2. [
] (321
POTABLE WATER 7 FT
[ ] [071 WATERTIGHT [
] (33]
BUILDING FOUNDATIONS 9 FT
[ ] [081 LEVEL [
] [341
PROPERTY LINES 7 FT
[ ] [091 DEPTH TO LID [
] [351
OTHER FT
DRAINFIELD INSTALLATION
FILLED
/ MOUND SYSTEM
[ ] (10] AREA [1] 504 (21 SQFT [
] [361
DRAINFIELD COVER
[ ] [111 DISTRIBUTION BOX HEADER X [
] [37]
SHOULDERS
[ ] [121 NUMBER OF DRAINLINES 1. 6.00 2. [
] [381
SLOPES
[ ] [131 DRAINLINE SEPARATION [
] [391
STABILIZATION 08/24/2021
[ ] [141 DRAINLINE SLOPE
[ ] [15] DEPTH OF COVER
ADDITIONAL
INFORMATION
[ ] [161 ELEVATION [ ABOVE / BELOW ]BM 2.00 [
] [401
UNOBSTRUCTED AREA
[ ] [171 SYSTEM LOCATION [
] [411
STORMWATER RUNOFF
[ ] [18] DOSING PUMPS (
] [42]
ALARMS
[ ] [191 AGGREGATE SIZE [
] (431
MAINTENANCE AGREEMENT
[ ] [201 AGGREGATE EXCESSIVE FINES [
] [441
BUILDING AREA
[ ] [211 AGGREGATE DEPTH [
] [451
LOCATION CONFORMS WITH SITE PLAN
[
] [46]
FINAL SITE GRADING
FILL / EXCAVATION MATERIAL
[ ] (221 FILL AMOUNT [ ] [471 CONTRACTOR Ernesto Gamez (SEPTIC EN
[ ] [231 FILL TEXTURE [ ] [481 OTHER
[ ] [241 EXCAVATION DEPTH ABANDONMENT
[ ] [251 AREA REPLACED [ ] (491 TANK PUMPED
[ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED 6 FILLED
Comments: Comments are on page 2.
CONSTRUCTION I APPROVEb / St. Lucie CHD
DISAPPROVED ) ' Environ ental-Specialistlll r' gram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM [ APpROVED / DISAPPROVED ]: ~� St. Lucie CHD
Environmental Specialist III n J Ingram (ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page) r'
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC
EH Database v 1.0.1 AP1659219 EID1862241
DATE: 06/17/2021
DATE: 08/24/2021
Page 2 of 3
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
'.y CONSTRUCTION INSPECTION AND FINAL APPROVAL
We'sss'`
Violation Number Comment
Comments
APPLICATION #:AP1659219
PERMIT #:56-SF-1862241
DOCUMENT # : FI 1683330
DATE PAID:04/28/2021
FEE PAID:305.00
RECEIPT #:56-PID-4956934
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300
gpd.
New ST, filter, and 6x7 long BED DF installed. No violations, system ok to cover, contractor notified onsite. Needs final
inspection for mound system and final site grading.
Final system approved. Contrator and building department emailed final approval.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1659219 EID1862241