HomeMy WebLinkAboutAPPROVED Gabriella Marcano_06-05-2021_Planset signed(1)7.6 KWSYSTEM SIZE :6.4 KW DC STCVICINITY MAPSITE MAP (N.T.S)A-01SITE MAP &VICINITY MAPGABRIELLA MARCANONEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEMDC SYSTEM SIZE (6.4 KW)33°C0°C0 PSF160MPH (ASCE 7-16)IIB32 A(1) GENERAC PWRCELL INVERTER APKEO0014LINE SIDE TAP IN THE MSPWIND FLOW MAP(2) BRANCHES OF 7 MODULES(1) BRANCH OF 6 MODULESSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021DC RATING OF SYSTEMAC RATING OF SYSTEMAC OUTPUT CURRENTNO. OF MODULESNO. OF INVERTERSPOINT OF CONNECTIONARRAY STRINGINGDESCRIPTIONNEW GRID-INTERACTIVE PHOTOVOLTAICSYSTEM WITH NO BATTERY STORAGESYSTEM DETAILSGOVERNING CODESFLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)NATIONAL ELECTRIC CODE, NEC 2017 CODE BOOK, NFPA 70SITE MAP & VICINITY MAPA - 01A - 02S - 01SINGLE LINE DIAGRAMWIRING CALCULATIONSSYSTEM LABELINGMODULE DATASHEETE - 01E - 02E - 03STRUCTURAL ATTACHMENT DETAILOPTIMIZER DATASHEETSNAPRS DATASHEETBATTERY DATASHEETDS - 01DS - 02DS - 03DS - 04S - 02SHEET INDEXSHEET NO.SHEET NAMEROOF PLAN & MODULESARRAY LAYOUTINVERTER DATASHEETATTACHMENT DATASHEETDS - 05DS - 06RACKING DATASHEETDS - 07SITE DETAILSASHRAE EXTREME LOWASHRAE 2% HIGHGROUND SNOW LOADWIND SPEEDRISK CATEGORYWIND EXPOSURE CATEGORY(20) Q.PEAK DUO BLK-G5 (320W) MODULESNO. OF OPTIMIZER(3) GENERAC PV LINK OPTIMIZER39.37"66.33"LAYOUT SUBJECT TO CHANGEBASED ON SITE CONDITIONSNO. OF BATTERIES(3) GENERAC PWRCELL BATTERYDRIVEWAYMSPUM(E) UTILITY METER(OUTSIDE HOUSE)(E) MAIN SERVICE PANEL(INSIDE HOUSE)(E) SERVICE DROPSWIMMING POOL3' SETBACK18" SETBACKROOF 1PV ARRAYPAPAYA DR BARTOW ST75'-7"122'-5"97'-10"99'-6"43'-9"28'31'-8"34'-10" A-02 & MODULESROOF PLANMODULE TYPE, DIMENSIONS & WEIGHTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3.BUILDINGSTRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFTWIND LOADS, AND EQUIPMENT DEAD LOADS. *GENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO TRUSSES SHALL BE INSTALLEDAS SHOWN IN SHEET S-01 AND AS FOLLOWS FOR EACH WINDZONE:.WIND ZONE 1: MAX SPAN 4'-0" O.C.WIND ZONE 2: MAX SPAN 4'-0" O.C.WIND ZONE 3: MAX SPAN 2'-0" O.C.2) EXISTING RESIDENTIAL BUILDING ROOF WITH MEAN ROOFHEIGHT 15 FT AND 2"x4" WOOD ROOF TRUSSES SPACED 24" O.C.CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THEENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANSAND IN FIELD CONDITIONS.LEGENDSUMACDPMMSP- UTILITY METERJB- AC DISCONNECT- PRODUCTION METER- MAIN SERVICE PANEL- VENT, ATTIC FAN (ROOF OBSTRUCTION)- JUNCTION BOXCP- COMBINER PANEL- CONDUIT- MICROINVERTER- FIRE SETBACKNUMBER OF MODULES = 20 MODULESMODULE TYPE = Q.PEAK DUO BLK-G5 (320W) MODULESWEIGHT = 41.22 LBS / 18.7 KG.MODULE DIMENSIONS = 39.37" X 66.33" = 18.13 SFNUMBER OF INVERTER = 1 INVERTERINVERTER TYPE = GENERAC PWRCELL INVERTER APKEO0014DC SYSTEM SIZE: 6.4 KWAC SYSTEM SIZE: 7.6 KWNOTES:1. LOCATION OF JUNCTION BOX(ES), ACDISCONNECTS(S), AC COMBINER PANEL(S), ANDOTHER ELECTRICAL EQUIPMENT(S) RELEVANTTO PV INSTALLATION SUBJECT TO CHANGEBASED ON SITE CONDITIONS.2. SETBACKS AT RIDGES CAN BE REDUCED TO18 INCHES IN COMPLIANCE WITH FBC R 324.6.2:TOTAL PLAN VIEW AREA = 2111.8 SQFTTOTAL PV AREA = 20(66.33 IN)(39.37 IN)/(144 IN^2) = 362.7 SQFT( 362.7 SQFT/ 2111.8 SQFT)100 = 17.17 %TOTAL PV AREA POPULATES 17.17 % OF TOTALPLAN VIEW AREA AND IS WITHIN THE 33%REQUIREMENT.M- METER MAIN COMBOBATTINV- BATTERY- INVERTERMSPUM(E) UTILITY METER(OUTSIDE HOUSE)(E) MAIN SERVICE PANEL(INSIDE HOUSE)ACDINV(N) AC DISCONNECT(N) INVERTERBATT(N) BATTERYJBROOF ACCESS POINT(E) SERVICE DROPROOF ACCESS POINT3' SETBACK18" SETBACKCONDUIT RUNROOF 1PV ARRAY(E) FRONT YARD (E) BACK YARD SWIMMING POOL S-01ARRAYLAYOUT(ROOF #1)ROOF DESCRIPTION:SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021MODULES - 20ROOF TILT - 23°ROOF AZIMUTH - 90°TRUSSES SIZE - 2"X4" @ 24" O.C.LEGENDS- VENT, ATTIC FAN (ROOF OBSTRUCTION)- PV ROOF ATTACHMENT- RAFTERS / TRUSSES- RAILS- FIRE SETBACKWIND LOAD INFORMATION:THIS SYSTEM HAS BEEN DESIGN TO MEETTHE REQUIREMENTS OF THE 7TH EDITION OFTHE FLORIDA BUILDING CODE AND USED THE FOLLOWING DESIGN PARAMETERS: ULTIMATE WIND SPEED: 160 MPHEXPOSURE CATEGORY: BRISK CATEGORY: IIMEAN ROOF HEIGHT: 15ROOF SLOPE: 20°-27°- WIND ZONE 1- WIND ZONE 1'WIND ZONE 2- WIND ZONE (2)- WIND ZONE (2r)- WIND ZONE (2e)- WIND ZONE (2n)WIND ZONE 3- WIND ZONE (3)- WIND ZONE (3r)- WIND ZONE (3e)- COUPLINGWIND ZONE 1ROOF #13' SETBACK18" SETBACK(E) SERVICE DROPSOLAR MODULE56'-6"15'15'-10"16'-2"33'-8"15' PHOTOVOLTAIC MODULE GENERAL NOTES:1. APPLICABLE CODE: 2020 FLORIDA BUILDING CODE 7th ED. & ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER NDS(2012)REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A WOOD ROOF TRUSS AS EMBEDMENT MATERIAL.3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLERESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27° (2/12 TO AMAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOTEXCEED 30'-0" MEAN ROOF HEIGHT.4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511.5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TOMANUFACTURERS' MANUAL FOR ALL ARCHITECTURAL, MECHANICAL,ELECTRICAL, AND SOLAR SPECS.6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESSOTHERWISE NOTED.7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED.8. ALL RAILING AND MODULES SHALL BE INSTALLED PERMANUFACTURERS' INSTRUCTIONS.9. I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCEWITH FBC:BUILDING CHAPTER 16 AND FBC:RESIDENTIAL CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATEDWIND LATERAL AND UPLIFT FORCES, AND EQUIPMENT DEAD LOADS.S-02STRUCTURAL ATTACHMENTDETAILSSTRUCTURAL ATTACHMENT DETAILSSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021SOLAR MODULE5/16"x4" STAINLESSSTEEL LAG SCREWWOOD SHEATHINGRAFTERSRAFTERSWOOD SHEATHINGQUICK MOUNT QRAIL LIGHTL FOOTRT MINI BASEQUICK MOUNT QRAIL LIGHT L FOOTRT MINI BASE NOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, NFPA 70 AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDINGMAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OFMODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURERAND MODEL NUMBER, INVERTER MANUFACTURER AND MODELNUMBER, AS APPLICABLE.2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTERSPACE IS INADEQUATE.E-01ELECTRICALLINE DIAGRAMINVERTER SPECIFICATIONSMANUFACTURERGENERACMODEL NO.SKU:APKE00014MAX DC INPUT VOLTAGE 420 VMAX OUTPUT POWER4600 WNOMINAL AC OUTPUT VOLTAGE 240 VNOMINAL AC OUTPUT CURRENT 32 ASHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021SOLAR ARRAY (6.4 KW-DC STC)(20)Q.PEAK DUO BLK-G5 (320W) MODULES(2) BRANCHES OF 07 MODULES(1) BRANCH OF 06 MODULESOPTIMIZER SPECIFICATIONMODEL NO.GENERAC PV LINKOPTIMIZEROPEN CIRCUIT VOLTAGE (Voc)420 VSHORT CIRCUIT CURRENT (Isc)18 AMAX. DC OUTPUT CURRENT8 AMODULE SPECIFICATIONMODEL NO.HANWHA Q PEAKDUO BLK-G5PEAK POWER320WRATED VOLTAGE (Vmpp)33.80 VRATED CURRENT (Impp)9.74 AOPEN CIRCUIT VOLTAGE (Voc)40.56 VSHORT CIRCUIT CURRENT (Isc)9.94 A200AGNGUM60A ACDISCONNECTFUSEDMAIN SERVICEPANEL120/240V200AGENERAC PWRCELLINVERTER APKEO001430AGENERACPOWERCORE30A1 STRING OF7 MODULESGG7 MODULES1 STRING OF1 STRING OF6 MODULESPWRCELLBATTERYPROTECTEDLOAD PANELPV LINKSUBSTRINGOPTIMIZER50A40A/2P(3) #8 AWG THWN-2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(3) #10 AWG THWN-2 - RED(3) #10 AWG THWN-2 - BLACK(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(3) #8 AWG THWN-2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNLINE TAP USINGINSULATIONPIERCING 705.12(A)(3) #8 AWG THWN-2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC, PVC, HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT CONDUIT RUN ELECTRICAL NOTES1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR75 DEGREE C.3. CONDUCTOR TERMINATION AND SPLICING AS PER NEC 110.144. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE ASPOSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.5. WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS.CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLECODES AND STANDARDS.7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITSARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELEDAND READILY VISIBLE.9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE310.10 (D).16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLEFOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C).E-02WIRINGCALCULATIONSSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021ELECTRICAL CALCULATIONS:1.CURRENT CARRYING CONDUCTOR(A)BEFORE IINVERTERAMBIENT TEMPERATURE = 33°CCONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(c)TEMPERATURE DERATE FACTOR - 0.96 ...NEC 310.15(B)(2)(a)GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a)CONDUCTOR AMPACITY= (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B)= [(8 x 1.56] / 0.96 / 0.8= 16.25 ASELECTED CONDUCTOR - #10THWN-2 ...NEC 310.15(B)(16)(B)AFTER INVERTERTEMPERATURE DERATE FACTOR - 0.96GROUPING FACTOR - 1 CONDUCTOR AMPACITY=(TOTAL INV O/P CURRENT) x 1.25 / 0.96 / 1 ...NEC 690.8(B)=[(32) x 1.25] /0.96 / 1=41.67 ASELECTED CONDUCTOR - #8 THWN-2 ...NEC 310.15(B)(16)2.PV OVER CURRENT PROTECTION ..NEC 690.9(B)=TOTAL INVERTER O/P CURRENT x 1.25=(32) x 1.25 = 40 ASELECTED OCPD = 40ASELECTED EQUIPMENT GROUND CONDUCTOR (EGC) = #10 THWN-2 ... NEC 250.122(A) WARNINGELECTRIC SHOCK HAZARD!DO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONPHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 32 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICEPHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDE-03WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNING PHOTOVOLTAICPOWER SOURCE!727-571- 4141EMERGENCY CONTACTWARNING!INVERTER OUTPUT CONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICEWARNING!DEDICATED SOLAR PANELS DONOT CONNECT ANY OTHER LOADSSHUTDOWNSOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWNSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021SYSTEMLABELINGLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION, COMBINER PANEL(PER CODE: NEC 690.13(B))LABEL LOCATION:AC DISCONNECT, INVERTER(PER CODE: NEC 690.54)LABEL LOCATION:CONDUIT RUNWAY(PER CODE: NEC690.31(G)(3)(4))LABEL LOCATION:MAIN SERVICE DISCONNECT(NEC 705.12(B)(3-4) & NEC 690.59)ADHESIVE FASTENED SIGNS:·ANSI Z535.4-2011 PRODUCT SAFETY SIGNS AND LABELS, PROVIDESGUIDELINES FOR SUITABLE FONT SIZES, WORDS, COLORS, SYMBOLS, ANDLOCATION REQUIREMENTS FOR LABELS. NEC 110.21(B)(1)·THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THEENVIRONMENT INVOLVED. NEC 110.21(B)(3)·ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLYADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT. IFC 605.11.1.3LABEL LOCATION:POINT OF INTERCONNECTION, MAIN SERVICE DISCONNECT(PER CODE: NEC 705.12 (B)(2)(c))[Not required if panelboard is rated not less than sum of ampere ratingsof all overcurrent devices supplying it]LABEL LOCATION:AC DISCONNECT, DC DISCONNECT, POINT OFINTERCONNECTION(PER CODE: NEC 690.56(C)(3))IFC 605.11.3.1(1) & 690.56(C)(1)(a) Label for PV Systems thatShut down the array and the conductors leaving the array DS-01DATASHEETMODULESHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021 DS-02SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021DATASHEETSNAPRS DS-03DATASHEETOPTIMIZERSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021 DS-04DATASHEETINVERTERSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021 DATASHEETBATTERYDS-05SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021 DATASHEETATTACHMENTDS-06SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021 DATASHEETRACKINGDS-07SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMKDESIGNERREVIEWERDATEGABRIELLA MARCANO 5902 PAPAYA DR, FORT PIERCE, FL 34982, USA Signature with SealADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777CONTACT : 727-571-4141LICENSE #AEC-07807ENGG.06/05/2021