Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCiE COUNTY City, State, Zip. FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(1718.3 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 c NIA R= ft2 4. Number of Bedrooms 1 d. NIA R= ft2 5. Is this a worst case? Yes 11. Ceiling Types(1336.0 sqft.) Insulation Area 6. Conditioned floor area above grade (ft2) 1306 a. Under Attic (Vented) R=30.0 1306.00 ft2 Conditioned floor area below grade (ft2) 0 b. Knee Wall (Vented) R=19.0 30.00 ft2 0 N/A R= ft2 7. Windows(128.9 sgft.) Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor Sgl, U=1.02 76.04 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 SHGC: SHGC=0.29 b. b. U-Factor: Sgl, U=1.03 40.00 ft2 C. SHGC: SHGC=0.27 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: Sg1, U=1.02 12.85 ft2 a. Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 14. Heating Systems kBtulhr Efficiency 8. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor:(AVG) NIA NIA ft2 SHGC(AVG): NIA 9. Floor Types Insulation Area 15. Hot Water Systems a. Slab -On -Grade Edge Insulation R= 0.0 2 1306.00 ft a. ElectricTankless Cap: 1 gallons b. NIA R= ft2 EF:0.600 c. NIA R= ft2 b. Conservation features None 16. Credits None Glass/Floor Area: 0.099 Total Proposed Modified Loads: 41.30 Total Baseline Loads: 43.21 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this ;%E57;- Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed .� Rrfr1 %- fi� ���-® this building will be inspected for a __ DATE: compliance with Section 553.908gi! Florida Statutes. " I hereby certify that this building, as des' . d is-irrcompliance with the Florida Energy CoOi)y;r'* OWNE NT: BUILDING OFFICIAL: DATE: DATE: - ....,r..a, — ,cZ ca un%,auvEF uy use air handler unn manuracturer tnat tree air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole horse. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 6/7/2021 11:47:00 AMA EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE COTTAGE IMPACT Address type: Street Address Building Type: User Bedrooms: 1 Lot #: - Owner. WYNNE BUILDING CORP. Conditioned Area: 1306 Block/SubDivision: - TotalStories: 1 PlatBook: - BuilderName: WYNNE BUILDING CORP. Worst Case: Yes Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY Rotate Angle: 180 County: St. Lucie Jurisdiction: Cross Ventilation: No City, State, Zip: FT. PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban YearConstruct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Dailytemp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range _FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 131076.2001953125 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _ 1 MASTER BEDROOM 234 1895.4 No 0 1 Yes Yes Yes _2 DEN 144 1166.4 No 0 Yes Yes Yes _3 SINK AREA 42 340.2 No 0 Yes Yes Yes _4 CLOSET 63 510.3 No 0 No Yes Yes _ 5 GREAT ROOM 452 3661.2 No 2 Yes Yes Yes _ 6 MASTER BATH 50 405 No 0 Yes Yes Yes _7 POWDER 25 202.5 No 0 No Yes Yes _8 KITCHEN 232 1879.2 Yes 0 Yes Yes Yes _9 LAUNDRY 40 324 No 0 No Yes Yes 10 STORAGE 24 192 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 1306 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins MASTER BEDROOM 31 0 234 ft 0.473 - 0.00 1.00 0.00 _2 Slab -On -Grade Edge Ins DEN 24 0 144It 0.473 - 0.00 1.00 0.00 _ 3 Slab -On -Grade Edge Ins SINK AREA 7 0 42 ft 0.473 - 0.00 1.00 0.00 _4 Slab -On -Grade Edge Ins CLOSET 1 0 63ft 0.473 - 0.00 1.00 0.00 _5 Slab -On -Grade Edge Ins GREAT ROOM 32 0 452It 0.473 - 0.00 1.00 0.00 _ 6 Slab -On -Grade Edge Ins MASTER BATH 5 0 50 ft 0.473 - 0.00 1.00 0.00 _7 Slab -On -Grade Edge Ins POWDER - 1 0 25ft OA73 - 0.00 1.00 0.00 _8 Slab -On -Grade Edge Ins KITCHEN 38 0 232It 0.473 - 0.00 1.00 0.00 _9 Slab -On -Grade Edge Ins LAUNDRY 1 0 40ft 0.473 - 0.00 1.00 0.00 10 Slab -On -Grade Edge Ins STORAGE 21 0 24ft 0.304 - 0.00 0.00 1.00 617)2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V# Type Materials Area Area Color .Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1376 ft' Oft= Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1306 ft' N N CEILING (Total Exposed Area = 1336 sq.ft.) # Ceiling Type Space R-Value Ins.Type Area U-Factor Framing Fmc. Truss Type _ 1 UnderAtfic(Vented) MASTER BEDROOM 30.0 Blown 234.Oft' 0.053 0.10 Wood _2 UnderAMc(Venled) DEN 30.0 Blown 144.0R' 0.053 0.10 Wood _3 UnderAttio(Vented) SINK AREA 30.0 Blown 42.0f 2 0.053 0.10 Wood _4 UnderAtfic(Vented) CLOSET 30.0 Blown 63.0ft' 0.053 0.10 Wood _5 UnderAtfic(Vented) GREAT ROOM 30.0 Blown 452.0ft' 0.053 0.10 Wood _6 UnderAtfic(Vented) MASTER BATH 30.0 Blown 50.0ft' 0.053 0.10 Wood _7 UnderAtfic(Vented) POWDER 30.0 Blown 25.0ft' 0.053 0.10 Wood _8 UnderAttic(Vented) KITCHEN 30.0 Blown 232.0ft' 0.053 0.10 Wood _9 UnderAttic(Vented) LAUNDRY 30.0 Blown 40.0ft' 0.053 0.10 Wood _ 10 UnderAttic(Vented) STORAGE 30.0 Blown 24.011' 0.030 0.11 Wood 11 Knee Wall(Vented) GREAT ROOM 19.0 Blown 30.W 0.045 0.11 Wood WALLS (Total Exposed Area = 1718 sq.ft.) Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project" section on page 1. Cavity Width Height Area U- Sheath Frm. Solar Below JAdjacent # Omt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _ 1 S=>N Exterior Conc. BIk- Int Ins MASTER BEDROOM 4.1 18.0 0 8.0 1 145.5 0.149 0 0 0.30 0% _2 W=>E Exterior Conc. Blk -Int Ins MASTER BEDROOM 4.1 13.0 0 8.0 1 105.1 0.149 0 0 0.30 0% _3 N=>S Exterior Conc. Blk -Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _4 W=>E Exterior Conc. Blk -Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _5 S=>N Exterior Conc. Blk -Int Ins SINKAREA 4.1 7.0 0 8.0 1 56.6 0.149 0 0 0.30 0% _ 6 N=>S Exterior Conc. BIk- Int Ins GREAT ROOM 4.1 22.0 0 8.0 1 177.8 0.149 0 0 0.30 0% _ 7 W=>E Exterior Conc. Blk- Int Ins GREAT ROOM 4.1 10.0 0 8.0 1 80.8 0.149 0 0 0.30 0% _ 6 S=>N Exterior Conc. BIk - Int Ins MASTER BATH 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _9 N=>S Exterior Conc. Blk -Int Ins KITCHEN 4.1 17.0 0 8.0 1 137.4 0.149 0 0 0.30 0% _ 10 E=>W Exterior Conc. Blk- Int Ins KITCHEN 4.1 16.0 0 8.0 1 129.3 0.149 0 0 0.30 0% _ 11 S=>N Exterior Conc. BIk - Int Ins KITCHEN 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _12 N=>S Exterior Conc. Blk -Int Ins KITCHEN 4.1 35.0 0 8.0 1 282.9 0.149 0 0 0.30 0% _ 13 N=>S Exterior Conc. BIk- Int Ins STORAGE 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _ 14 N=>S Exterior Conc. Blk - Int Ins STORAGE 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.30 0% 15 N=>S Garage Frame - Wood MASTER BEDROOM 11.0 30.0 0 8.0 0 240.0 0.092 0 0.23 0.30 0% DOORS (Total Exposed Area = 20 sq.ft.) / Width Height V# Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area 1 E=>W Insulated KITCHEN None 0.32 3.00 0 6.00 8 20.01t 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 129 sq.ft.) / Wall ----- Overhang- / # Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation InteriorShade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N N 32.412 1.0 ft 5 in 1.0 It 5 in None None _ 2 W=>E 4 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft 1.0 ft 5 in 1.0 It 5 in None None _ 3 N=>S 6 Metal Low-E Single Yes 1.02 0.29 N N 18.412 ft 5 in 1.0 ft 5 in None None -4 W=>E 7 Metal Low-E Single Yes 1.03 0.27 N N 40.011 12.0 ft 0 in 1.0 ft 5 in None None -5 S=>N 8 Metal Low-E Single Yes 1.02 0.29 N N 6.02 1.0 ft 5 in 1.0 ft 5 in None None 6 E=>W 10 Metal Low-E Single Yes 1.02 0.26 N N 12.8ft' 1.0 ft 5 in 1.0 ft 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00026 881 48.35 90.78 0.0907 5.0 All GARAGE # FloorArea Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280 IF 280 ft2 35 ft 8 ft 11 MASS # Mass Type Area Thickness FumitureFraction Space _ 1 DefaulgBlbs/sq.ft.) 0 ft' 0 ft 0.30 MASTER BEDROOM _2 Default(81bs/sq.fL) 0 ft2 ft 0.30 DEN _ 3 Default(8lbs/sq.ft.) 0 ft- 0 ft 0.30 SINK AREA _4 Default(Blbs/sq.fL) Oft' Oft 0.30 CLOSET -5 Default(8lbs/sq.ft.) 0 ft2 0 ft 0.30 GREAT ROOM _6 Default(8lbs/sq.ft.) 0 ft' 0 ft 0.30 MASTER BATH _ 7 Defaul481bs1sq.ft.) 0 ft2 0 ft 0.30 POWDER -8 Default(8lbs/sq.ft.) 0 ft' 0 ft 0.30 KITCHEN _ 9 Default(8lbs/sq.ft.) 0 ft' 0 ft 0.30 LAUNDRY -10 Default(8lWsq.ft.) 0 ft' Oft 0.30 STORAGE HEATING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity -GeothermalHeatPump- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Heat Pump Split/Single HSPF: 8.20 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm _1 Central Unit Split/Single SEER:14.0 29.0 0 0.80 sys#1 1 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length 1 Electric Tankless Garage 0.60 (0.60) 1.00 gal 61 gal 120 deg Standard None 82 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR OtherCredits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS —Suppty-- --Return— Air CFM 25 CFM 25 HVAC # vDud # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT QN RLF Heat Cod 1 Attic 6.0 120 ft' Attic 6.0 45 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [] Feb [ ] Mar [ ] Apr [] May [X] Jun Pq Jul [X) Aug [X] Sep [] Oct [ ] Nov [ ] Dec Heating [X] Jan [X] Feb [X] Mar [ ] Apr [] May [] Jun []Jul [ ] Aug [ ] Sep [] Oct [X) Nov [X] Dec Venting [] Jan [] Feb [X] Mar [X] Apr [I May [ ] Jun []Jul []Aug [ ] Sep [X] Oct [X] Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours �/ Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 —Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _ Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _Heating (WD) PM 68 68 68 68 68 68 68 68 68 68 68 68 _Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 677/202111:47:00 AM EnergyGauge®USA 7.0.00- FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: WYNNE BUILDING CORP. Jurisdiction: U Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barriershall be installed in the building envelope. Air-permeableinsulationshall requirements The exteriorthermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be Sealed - The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exteriorthennal envelope insulation forframed walls shall be installed in substantial contactand continuous alignmentwith the airbarrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subflcordeckin ,or floor g cavity insulation andcantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class l vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrowcavities Batts in narrow cavities shall be cut to fit, or narrow Cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garageseparation Air sealing shall be provided between the garage and conditionedspaces. Recessedlighting Recessed lightfudures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on " installation readily conforms to available space shall extend behind piping and wiring. Showeritub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall on exteriorwall and tubs shall separate them from the showers and tubs. beinsulated. Electrical/phonebox The air barrier shall be installed behind electrical or on exteriorwalls communication boxes orair-sealed boxes shall be installed. HVAC register boot HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, Inspection of log walls shall be in accordance with the provisions of ICC-400. 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. THE COTTAGE,FT. PIERCE,FL, 1. New construction or existing New (From Plans) 2. Single family or multiple family Detached 3. Number of units, if multiple family 1 4. Number of Bedrooms 1 5. Is this a worst case? Yes 6. Conditioned Floor area above grade (f:2) 1306 Conditioned floor area below grade (ftz) 0 7. Windows** Description Area a. U-Factor. Sgl, U=1.02 76.04 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.03 40.00 fe SHGC: SHGC=0.27 c. U-Factor: Sgl, U=1.02 12.85 ftZ SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 8. Skylights Description Area U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R= 0.0 1306.00 ftZ b. N/A R= fe c. N/A R= ftZ 10. Wall Types(1718.3 sqft.) Insulation Area a. Concrete Block- Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ftZ c. WA R= ftz d. N/A R= ft2 11. Ceiling Types(1336.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ft2 b. Knee Wall (Vented) R=19.0 30.00 ftz c. N/A R= ftZ 12. Ducts, location & insulation level R ftZ a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 b. C. 13. Cooling Systems kBtu/hr Efficiency a. Central Unit 29.0 SEER:14.00 14. Heating Systems kBtu/hr Efficiency a. Electric Heat Pump 27.0 HSPF:8.20 15. Hot Water Systems a. ElectricTankless Cap: 1 gallons EF: 0.600 b. Conservation features None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: THE COTTAGE City/FL Zip: FT. PIERCE,FL, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. *"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 677/2021 11:47:00 AM EnergyGauge® USA 7.0.00- FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 ® Project Summary o te: wrightsaft Entire House By. QUICK CALCS, INC. 317 ST.LUC3E LANE, FORMIERCE, FL34W PhDm:772-066-6799 Email:QUICKCALCS@AOL.COM For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL Notes: Design Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outsidedb 42 OF Outsidedb 90 OF Insidedb 70 OF Insidedb 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16327 Btuh Structure 15522 Btuh Duds 4013 Btuh Duds 5251 Btuh Central vent (0 cim) 0 Btuh Central vent (0 cfin) 0 Btuh none e) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipmentload 20340 Btuh Use manufacturer's data n Infiltration Rate/swing multiplier Equipment sensible load 0.95 19734 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2094 Btuh Duds 1524 Btuh Central vent (0 ctm) 0 Btuh Heatingg Area Coolingg (none) (f12) 1306 1306 Equipment latent load 3618 Btuh Volume (fr) 10579 10579 Airchanges/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 23352 Btuh Equiv.AVF (cfrn) 79 41 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB03000GOA0 Cond CH14NBO3000GOA0 AHRI ref 9162387 Coil FX4DNBO43L AHRI ref 9162387 Effidency 8.2 HSPF Efficiency 11.5 EER,14 SEER Heating input Sensible cooling 20300 Btuh Heating output 28000 Btuh@47°F Latentcooling 8700 Btuh Temperature rise 26 OF Total cooling 29000 Btuh Actual airflow 967 cfm Actual airflow 967 cfm Airflowfactor 0.048 dm/Btuh Airflowfactor 0.047 ctm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point = 34 OF Backup: Input=5 kW, Output=18005 Btuh, 100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. Ay Wrp^g^"~^ c6Q RigItSute® Lhiversa1201919.021 RSU08101 2021-JarF121 Page 1 /6.C.t. Pagel .SWngt6oft HUAC\WYNNE BUIDLING-THE COTTAGE.ny Ca1c=M18 Frort Doorhces:SW Ll' wrightsoft° Right-J® Worksheet Job: Entire House Date: BY QUICK CALCS, INC. 317 ST. LUCE LANE, FORr PIERCE, FL34946 Ph w772-4666799 EmiI:OUICKCALCS@AOLCOM 1 Room name Entire Home MASTER BEDROOM 2 bposedwall 145.0 It 31.0 2 3 Room height 8.1 it 8.1 It heabbod 4 5 Room dimensons .Room area 130&0 ft 234.0 13A x 1&0 ft ft Ty Conshiction rwmber U- lue (BWhdk'g Or HTM (BWhAn Area a perimeRr (it) Load @Wh) Area (ft� or perimeter (10 Load (Bluh) Heat Cool Gros NIP/. Heat Cool Gross NIP/. Heat Cool 6 Vf/ 13A-4= 0.143 n 4A0 2-19 446 427 1710 934 0 0 0 0 �C 2glazingdrouh, 13AA= 1A40 0.143 n a 29.12 4A0 21.68 2.19 - 18 162 0 129 537 516 -400 282 0 0 0 0 0 0 0 0 11 2 gg6ong,drouh, 11D0 1.040 03M a a 29.12 10.92 39.42 10.34 13 20 2 20 368 223 498 211 0 0 0 0 0 0 0 0 lR/ t-G 13A4= 2glaar�q,draN, 0.143 1D40 a s 4A0 29.12 2.19 21M 284 7 277 7 1107 202 . 605 150 146 0 146 0 584 0 319 0 l(V 13A4= 0.143 w 4A0 219 294 192 767 419 105 73 291 159 1A-dw 1A-h1w 1270 1270 w w 355S 3556 3M1.77 61.76 41 18 41 3 1451 656 1419 1139 0 0 0 0 0 0 0 0 L��GG 1A411om 1270 w 35.56 63.40 33 5 1162 2072 33 5 1162 2072 C 16C-3)Ml - 01M - 0.90 128 1306 1306 1170 1672 234 -234 210 300 F 22A-1pl 0M - 27.9 0.00 1306 145 4015 0 234 31 8% 0 6 c)AED u rson 3591 997 Erwelope low/gain 13885 13393 3105 3847 12 a) Mll ation 2441 868 522 143 b) Room lerNlauon 0 0 0 0 13 Internal gain Omlpants@ 230 2 460 0 0 APPIMMSfolher 1000 0 .ubt3fal(1ines61o13) 116327115522 3627 3990 Lesextamalload 0 0 0 0 Lestransfer 0 0 0 0 Redishbubon 0 0 0 0 14 Subtotal 16327 15522 3627 3990 15 Dudloads 25% 34% 4013 5251 25% 34% 892 1352 Total room load Air required (dm) 20340 967 20773 967 4518 215 5342 249 Calculations aoproved-bTACCA to meet all requirements of Manual J 8th Ed . 20214a 121321#0 RigkTHE CO rAGE p Calc.021 RS rort Do Page 1 ..ANrigtC;oftHVAG\VJYNNE BUIDLING-THE COTiAGEnp CaIc=MIS Frort Doorfaces SW wrighilsoft- Right-JO Worksheet '°b'. Entire House per` By. QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 P1nne: 772-466.6799 E.il:OUICKCALCS@AOL.COM 1 Room name DEN SINKAREA 2 Elrposedwall 24D It 7.0 It 3 Room height 8.1 It heaVWol 8.1 R heaVcool 4 Room dimensions 12.0 x 12.0 It 6.0 x 7.0 It 5 Roomarea 144.0 IF 42.0 IF Ty Construction U-value or HTM Area number (Bluh41;°F) (BWh/M or perimeter (R) (Btuh) or perimeter (fl) (BWh) Heat Cool Gross N/Pr5 Heat Cool Gros N/PS Heat Cool 6 W 13A-4= 0.143 n 4.00 2.19 97 97 389 213 0 0 0 0 �-C 2giaang,droutr, 1A40 n 29.12 21.68 0 0 0 0 0 0 0 0 moo s 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing, droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 t-G 13A-0us 0.143 s 4.00 2.19 0 0 0 0 57 57 227 124 2glaang,droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 13AAo s 0.143 w 4.00 2.19 97 79 315 172 0 0 0 0 tAclom 1270 w 3556 34.77 0 0 0 0 0 0 0 0 IA-htom 1270 w 35.56 61.76 18 3 656 1139 0 0 0 0 1A-htom 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C30ml 0.032 - 0.90 128 144 144 129 184 42 42 38 54 F 22A-tpl 0.989 - 27.69 0.00 144 24 665 0 42 7 194 0 6 c)AED exnnsion 574 -3 Envelope losagain 2154 2283 1 459 175 12 a) Infiltration 404 111 118 32 b) Roomvenllatlon 0 0 0 0 13 Internal gains: O=par%@ 230 0 0 0 0 Applianoes/other 0 0 Subtotal(lines6w 13) 12558 2394 576 207 Lesel�mal loatl 0 0 0 0 Lestrarafer 0 0 0 0 Retlistribution 0 0 0 0 14 Subtotal 2558 2394 576 207 15 Duct loads 25% 34% 629 811 25% 34% 142 70 Total room load 3167 3205 718 278 Airrequired (dm) 152 149 1 34 13 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wVjqftvs�� Aft, RigtlSul@ Udwrsa1201919.021 RS1/08101 2021-Jarv721321:40Page t ...\W69ttoftWACIWVNNESUIDLING-THECOTTAGEnp Calc=tM FrortDoorfams:SW I�a wrightsoft° Right-JO Worksheet Job: Entire House °a. By. QUICK CALCS, INC. 317ST. LUCIE LAPS, FORTPIERCE,FL34946 PInre:772A66-6799 EmaiI:QU1CKCALCS@AOL.00M 1 Room name CLOSET GREAT ROOM 2 E1posdwall 0 It 32D ft 3 Room height 8.1 ft heaNmol 8.1 It he&ood 4 5 Room dim7.ons Room area 9D x 7.0 ft 630 fF 1A x A .O ft 452D ft Ty Coratrucfion U-wlue or HTM Area (ft-) Load Area (fl) Load number (BWhnt-*9 (BWhAM or perimeter (fl) 1 (BWh) or perimeter (ft) (BWh) Hear Cool Gross NIPS Heal Cool Gros: NIPS Heat Cod 6 W 13A4o s 0.143 n 4.00 2.19 0 0 0 0 178 160 640 350 _ 2glaang,droutr, 13A4xs IMO 0.143 n a 29.12 4DO 21,68 2.19 0 0 0 0 0 0 0 0 18 0 0 0 637 0 400 0 1'I 2gla2ing,droutr, 11DO 1D40 0.390 a a 29.12 1092 39A2 10.34 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A4= 2glaarg,droutr, 0.143 1D40 a a 4A0 29.12 2.19 21.68 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 13A4ots 0.143 w 4D0 219 0 0 0 - 0 81 40 161 88 1Aciom to-htom 1270 1270 w w 3555 3556 34.77 61.76 0 0 0 0 0 0 0 0 41 0 41 0 1451 0 1419 0 1AN= 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 16C-30m1 094 - 090 128 63 63 56 81 452 452 405 679 F 22A-1pl 0989 - 27B9 ODO 63 0 0 0 452 32 886 0 6 c)AEDe=rson _1 2D69 Emelope loss(gain 56 80 4080 4903 12 a) hfiltralon b) Roomwnfilafion 0 0 0 0 639 0 148 0 13 trlemelgairs: Ocupanls@ 230 0 0 2 460 Appliarws/othw 0 0 Subbtal(linea6to13) 56 80 4619 5511 Lesseftmallced 0 0 0 0 14 Lesstrarsfer Redistribution Subhlhal 0 0 56 0 0 80 0 0 4619 0 0 6511 15 Ductbads 250/6 34% 14 27 259% 34% 1135 1868 Total mom load Air required (dm) 70 3 107 5 5754 274 7379 343 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed 'rw w loft vc f!".lak 2021.km121321 #0 RigrrSLiWOUriversa1201919.021 RSLWIO7 P�e3 ...lWngttof WAQWYNNEBUIDLING-7HECOTTAGEAp Calc=M16 FrortDoorfaws SW wr7ghtsoft° Right-J® Worksheet Job: Entire House °fit QUICK CALCS, INC. BY 317 ST.Lt/CIE LANE, FORTMERCE, FL34946 PMre:772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name MASTER BATH POWDER 2 E.Nposed%all 5D ft 0 ft 3 Room height 8.1 It heWcool 8.1 It heatlmol 4 Room dimensions 10A x 5.0 It 5.0 x 5.0 ft 5 Roomarea 50D fF 25.0 fF Ty Construction U-value Or HTM Area Load Area (ft� Load number (Bfu11AF2F) (BWh" or perimeter (ft) (Bfuh) or perimeter (ft) (Bluh) Heat Cool Gross N1PIS Heat Cool Gross WP/S Heat Cool 6 Vfl 13A-0as 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 �C 2glaang,drou,, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 l�l 13A4= 0.143 a 4.00 219 0 0 0 0 0 0 0 0 ILA_ 2 glazing, droufr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 D 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 13A4ors 0.143 s 4.00 2.19 41 34 134 73 0 0 0 0 G 2glaang,droutr, 1.040 s 29.12 21.68 7 7 202 150 0 0 0 0 13A-0as 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1Ac1cm 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 1A-h1om 1270 w 3556 61.76 0 0 0 0 0 0 0 0 1A-hlom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 16C301111 DM2 - 090 128 50 50 45 64 25 25 22 32 F Mmpi 0989 - 27.69 0.00 50 5 138 0 25 0 0 0 6 o)AED excurson 4 0 Envelopelossgain 520 284 22 32 12 a) Infiloa4on 84 23 0 0 b) Roomventlation 0 0 0 0 13 bremal gains Omlpants@ 230 0 0 0 Appliancedother 0 0 0 Subtotal(linesftl3) 604 307 22 32 Lessexamalload 0 0 0 0 Less Iansfer 0 0 0 0 Red�ibutlon 0 0 0 0 14 Subtotal 604 307 22 32 15 Duct loads 250/6 306 148 104 25% 34% 6 11 Toni room load 752 411 28 42 Airrequired(dm) 36 19 1 2 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed '�`� wrigtiLsof!- AAA RigtHE Um2021-J2n121321A0 ersa1201919.021 RSU08101 ...\Wngdsoft HVAgWYNNE BUIDLING-T-TtiE C OTTAGE.np Calc=M78 FrortDaorfaoss:SW Page 4 wrightsoft- Right-J@ Worksheet Job: Entire House Data: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772466-6799 Email: QUICKCALCS@AOLdJM 1 Room name KITCHEN LAUNDRY 2 Eposedwall 38.0 it 0 It 3 Room height 8.1 ft heaVcool 8.1 ft heatl000l 4 Room dimendons 1.0 x 232.0 ft 4.0 x 10.0 ft 5 Rcomarea 232.0 ft' 40.0 1F Ty Construction U-value Or HTM Area (ft� Load Area (IF) Load number (BWhAF2F) (Btuhr) or perimeter (ft) (Btuh) or perimeter (ft) (BWh) Heat Cool Gross NP5 Heat Cool Gross NP/9 Heat Cool 6 1Rl 13A-4= 0.143 n 4.00 2.19 138 138 551 301 0 0 0 0 I-G 2glazing, droutr, 1A40 n 29.12 21.68 0 0 0 0 0 0 0 0 13A-4= 0.143 a 40 2.19 130 97 387 211 0 0 0 0 2glaang,droutr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 11DO 0,390 a 10.92 10.34 20 20 223 211 0 0 0 0 W 13A-4= 0.143 s 4.00 2.19 41 41 162 89 0 0 0 0 I-C 2glaarg,droutr, 1.040 s 29.12 21 b8 0 0 0 0 0 0 0 0 13A4ors 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1A-ctom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 1A-hlom 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 1A-h1om 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 16C-30mi 0.032 - 0.90 128 232 232 208 297 40 40 36 51 F 22A-Ipl 0.989 - 27.69 0.00 232 38 1052 0 40 0 0 0 6 c)AED e=raon 37 -1 Envelopelossngain 2951 1570 36 51 12 a) IrAltrallon 640 175 0 0 b) Room wriblation 0 0 0 0 13 internal gains: C=pants@ 230 0 0 0 0 Applianossnoher 1000 0 Subbal(lines6to13) 3591 2745 36 51 Lessextemalload 0 0 0 0 Les;tranYer 0 0 0 0 Redistribution 0 0 14 Subtatal 3.591 2745 36 50 15 Ducticads 25% 34% 883 931 25% 34% 9 17 Total room load 4474 3676 45 68 Air required (dm) 213 171 2 3 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed '}'� wH9hisoTC ..Rigk-s2 9.02101 2021-Jam121321:40 .\Wrgt�oftHVAG1WYNNEBUIDLING-THErOTrAGE.q Calc=M18 FmMDoorfacesSW Page 5 -r� wrightsoft° RighWO Worksheet Joey Entire House Date: QUICK CALCS, INC. ey 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Email:QUICKCALCS AOL.COM 1 Room name STORAGE 2 Epwsd wall 8.0 ft 3 Room height 8.1 ft heaVcool 4 Room dimendons 4.0 x 6.0 ft 5 Room area 24p 1F Ty Construction U-value Or HTM Area M Load Area Load number (BtuWF F) (ftw) or perimeter (ft) (Btuh) or perimeter Heat Cool Gros N/M Heat Cool Gross N/P/8 Heat Cool 6 V}/ 13A-4= 0.143 n 4A0 2.19 $2 32 130 71 �—G 2glaang,droutr, 1.040 In 29.12 21 b8 0 0 0 0 y/ 13A-4os 0.143 a 4.00 2.19 32 32 130 71 2glaang, or outr, 1A40 a 29.12 39.42 0 0 0 0 11 IL—G D 11DO 0.390 a 1092 10.34 0 0 0 0 13A4= 0.143 s 4.00 2.19 0 0 0 0 2glaang,droutr, 1.040 s 29.12 21.68 0 0 0 0 y/ 13A-0gs w 4.56 0 0 0 0 1ACIam 1270 1270 w 3556 4.77 0 0 0 0 1A-h7am 7270 w 3556 61.76 67.76 0 0 0 0 IA-hiom 1270 w 3556 63.40 0 0 0 0 C 16C30ml 0.032 - 0.90 128 24 24 22 31 F 22A->) 0.989 - 27.69 0.00 24 8 222 0 6 c)AEDemnsion 3 Enselopelos/gain 502 170 12 a) hfiftion 130 37 b) Rcomwntilation 0 0 13 Intemalgaim Occupants@ 230 0 0 Apptiano�qother 0 SuWal(lines6b13) 637 207 Lessekemal load 0 0 Leshan*r 0 0 Redistribution 0 0 14 Subtotal 637 207 75 Dud 25% 29% 157 60loatls tip Total room load 794 266 Air required (dm) 38 12 Calculations approved WACCAto meet all requirements of Manual J 8th Ed wrl9h>csolt� 9LA ...R9rS OUrA9021 RSU08101 :2021J,-121321:40 1Wdgt6oftVACWYNNEBUIDLING-HECGTGE..rup CaIc=MFrortLborfaoa53W Page ® Duct System Summary t: wrightsoft y CY Date: Entire House BY QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phae: 772466-6799 Email: QUICKCALCS@AOL.COM Project Information For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply/return available pressure Lowest friction rate Actual airflow Total efective length (TEL) Heating 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 clin 126 Supply Branch Detail Table Cooling 0.50 in H2O 028 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 d n Name Design (Btuh) Htg (Clm) Clg (Cfm) Design FR Diam (in) H x W (in) Dud Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk CLOSET c 107 3 5 0.080 4.0 Ox0 VIFx 24.6 90.0 st1 DEN h 3187 152 149 0.080 7.0 OxO VIFx 33.5 90.0 st1 GREAT ROOM c 3689 137 172 0.080 8.0 Ox0 VIFx 14.6 70.0 GREATROOM-A c 3689 137 172 0.080 8.0 OxO VIFx 16.1 70.0 KRCHEN h 4474 213 171 0.080 7.0 OxO VIFx 4.5 70.0 LAUNDRY c 68 2 3 0.080 4.0 OxO VIFx 5.4 70.0 MASTERSAiFi h 752 36 19 0.080 4.0 OxO MFx 32.9 90.0 st1 MASTERBEDROOM C 2671 107 124 0.080 7.0 OxO VIFx 27.9 90.0 st1 MASTERBEDROONM C 2671 107 124 0.080 7.0 1 VIFx 35.9 90.0 st1 POWDER C 42 1 2 0.080 4.0 OXO VIFx 292 90.0 SO SINKAREA h 718 34 13 0.080 4.0 Ox0 VIFx 30.9 90.0 st1 STORAGE h 794 38 12 0.080 4.0 Ox0 VIFx 11.2 70.0 Name Trunk Type Htg (cfm) Clg II IJesign FIR Veloc (fpm) I Im (in) H x W (in) Duct Material Trunk st1 PeakAVF 441 437 0.080 561 12.0 0 x 0 VinIFIX f' Wrightsoft- 2021-Jam121321:41 RJgkStiL@Uri.r 1201919.021 RSU06101 Page 1 ...\WrigY�oft HVACtWYNNE BUIDLING-THE COTTAGEnp CaIc=MIB Frori Doorhces SW Name Grille Size (in) Htg (Cfm) CI9 (Cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Dud Mat Trunk rbl OxO 967 967 0 0 0 0 Ox 0 MR WrightsoRm 2021Ja 121321:41 �.o..: ...��.., RigHSULVL i er.1201919.021 RSU08101ACM Page ...1WrighsoftWADWYNNESUIDLING-THECOTTAGE.rup C lc=MI8 Frort Door fares: SW