HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL J - 22 GRANADA SOUTH(1)FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: WYNNE BUIDLING-THE COTTAGE IMPACT
BuilderName: WYNNE BUILDING CORP.
Street: THE COTTAGE
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CORP.
Jurisdiction:
DesignLocation: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Types(1718.3 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block- Int Insul, Exterior
R=4.1 1478.30 ft2
b. Frame -Wood, Adjacent
R=11.0 240.00 ft2
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 1
d.N/A
R= ft2
5. is this a worst case? Yes
11. Ceiling Types (1315.0 sgft.)
Insulation Area
a. UnderAttic (Vented)
R=30.0 1295.00 ft2
6. Conditioned floor area above grade (ft2) 1285
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floorarea belowgrade (ft2) 0
c. NIA
R= ft2
7. Windows(128.9 sgft.) Description Area
12. Ducts
a. Sup: Attic, Rat: Attic, AH: Attic
R ft2
6 120
a. U-Factor: Sgl, U=1.02 76.04 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgi, U=1.03 40.00 ft2
13. Cooling systems
kBtulhr Efficiency
$HOC: SHGC=0.27
a. Central Unit
29.0 SEER:14.00
c. U-Factor: SgI, U=1.02 12.85 ft2
SHGC: SHGCg
Area Weighted Average Overhang Depth: 4.701 ft.
14.Heatingsystems
kBtulhr Efficiency
Area Weighted Average SHGC: 0.281
a. Electric Heat Pump
27.0 HSPF:8.20
8. Skylights Area
c. U-Factor:(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric Tankless
Cap:1 gallons
9. Floor Types (1285.0 sgft.) Insulation Area
EF:0,600
a. Slab -On -Grade Edge Insulation R=0.0 1285.00 ft2
b. Conservation features
b. N/A R= ft2
None
c_ NIA R= ft2
16. Credits
None
Total Proposed Modified Loads: 40.90
GlasslFioorArea: 0.�00
PASS
Total Baseline Loads: 42.89
I hereby certify that the plans and specifications covered by
Review of the plans and
got5
this calculation are in compliance with the Florida Energy
specifications covered by this�j
Code. a
calculation indicates compliance
With the Florida Energy Code.
rlar�r. �••,` ` 9
PREPARED BY;
5-4-2®2�
Before construction is completed
DATE:
this building will be inspected for
d Al
compliance with Section 553.908
I hereby certify that this building, as de si ned -' mpliance
Florida Statutes.
with the Florida Energy
WE
OWNERLAkP
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
5/4/2021 7:07 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE BUIDDING-THE COT Bedrooms: 1
Address Type:
Street Address
Building Type: User
ConditionedArea: 1285
Lot#
OwnerName: WYNNE BUILDING CORP. Total Stories: 1
Block/Subdivision:
#of Units: 1
Worst Case: Yes
Pla Book:
BuilderName: WYNNE BUILDING CORP. RctateAngle: 180
Street:
THE COTTAGE
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County.
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Detached
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design DailyTemp
V Designt-ocation
TMY Site 97.5%
2.5%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1285 10406.1
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 MASTER BEDROO
213 1725.3 No
0
1
1 Yes
Yes
Yes
2 DEN
144 1166.4 No
0
1 Yes
Yes
Yes
3 SINKAREA
42 340.2 No
0
1 Yes
Yes
Yes
4 CLOSET
63 510.3 No
0
1 No
Yes
Yes
5 GREAT ROOM
452 3661.2 No
2
1 Yes
Yes
Yes
6 MASTER BATH
50 405 No
0
1 Yes
Yes
Yes
7 POWDER
25 202.5 No
0
1 No
Yes
Yes
8 KITCHEN
232 18792 Yes
0
1 Yes
Yes
Yes
9 LAUNDRY
40 324 No
0
1 No
Yes
Yes
10 STORAGE
24 192 No
0
0
1 Yes
Yes
Yes
FLOORS
# RoorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab-On-GradeEdge Insulation
MASTER BEDRO 31 It 0
213 ft-
__--
0 1
0
2 Slab-On-GmdeEdge Insulation
DEN 24ft 0
144W
----
0 1
0
3 Slab -Or Grade Edge Insulation
SINKAREA 7ft 0
42 ft-
----
0 1
0
4 Slab-On-GradeEdgelnsulation
CLOSET t ft 0
63IF
----
0 1
0
5 Slab-On-GradeEdgelnsulation
GREAT ROOM 32ft 0
452 ft-
----
0 1
0
6 Slab-On-GradeEdge Insulation
MASTER BATH 5ft 0
50 ft'
____
0 1
0
7 Slab-On-GradeEdge Insulation
POWDER 1 ft 0
25 IF
--__
0 1
0
5/4/2021 7:07 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
FloorType Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile
Wood Carpet
8SIab-On-GradeEdgelnsulation KITCHEN 38ft
0
232 ft-
____
0
1
0
9 Slab -On -Grade Edge Insulation LAUNDRY 1 ft 0
40 ft-
0
1
0
1 OSlab-On-Grade Edge Insulation STORAGE 21ft 0
24W
____
0
0
1
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1354 ft2
Oft'
Light
N
0.6
No 0.9
No 0
18.43
ATTIC
/
`�
#
Type Ventilation
Vent Rabo (1 in)
Area
RBS
IRCC
1
Fullattic Vented
150
1285ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
UnderAttic(Vented) MASTER BEDRO 30
Blown
213 ft-
0.1
Wood
2
UnderAttic(Vented) DEN
30
Blown
144 ft2
0.1
Wood
3
UnderAttiC(Vented) SINK AREA
30
Blown
42 ft'
0.1
Wood
4
UnderAttic(VeMed) CLOSET
30
Blown
63 ft'
0.1
Wood
5
UnderAtfc(Vented) GREAT ROOM
30
Blown
452 ft2
0.1
Wood
6
UnderAttic(Vented) MASTER BATH
30
Blown
50W
0.1
Wood
7
UnderAttic(Vented) POWDER
30
Blown
251t'
0.1
Wood
8
UnderAttic(Vented) KITCHEN
30
Blown
232f2
0.1
Wood
9
UnderAttic(Vented) LAUNDRY
30
Blown
40 ft'
0.1
Wood
10
UnderAttic(Vented) STORAGE
30
Blown
24 ft'
0.11
Wood
11
Knee Wall (Vented) GREAT ROOM
19
Blown
30W
0.11
Wood
WALLS
Mt
Adjacent Space Cavity Width
10 WnIllyo_a
Height
Sheathing Framing
Solar Below
1
S=>N
Exterior Concrete Block - Int lnsuMASTERBE
4.1 18
0 8
1
145.5f2
0
0
0.3
0
2
W=>E
Exterior Concrete Block-Int lnsuMASTER BE
4.1 13
0 8
1
105.1 ft2
0
0
0.3
0
_3
N=>S
Exterior Concrete Block - Int lnsul DEN
4.1 12
0 8
1
97.0 ft2
0
0
0.3
0
_4
W=>E
Exterior Concrete Block - Intlnsul DEN
4.1 12
0 8
1
97.0 ft'
0
0
0.3
0
_5
S=>N
Exterior Concrete Block- Int lnsulSINK AREA
4.1 7
0 8
1
56.6 ft'
0
0
0.3
0
_ 6
N=>S
Exterior Concrete Block- Int InsuGREAT ROO
4.1 22
0 8
1
177.8 ft-
0
0
0.3
0
7
W=>E
Exterior Concrete Block- Int lnsuGREAT ROO
4.1 10
0 8
1
80.8 ft2
0
0
0.3
0
8
S=>N
Exterior Concrete Block- Int lnsuMASTER BA
4.1 5
0 8
1
40.4 ft-
0
0
0.3
0
9
N=>S
Exterior Concrete Block-Intlnsul KITCHEN
4.1 17
0 8
1
137.4f2
0
0
0.3
0
10
E=>W
Exterior Concrete Block - Intlnsul KITCHEN
4.1 16
0 8
1
129.3 f12
0
0
0.3
0
11
S=>N
Exterior Concrete Block - Intlnsul KITCHEN
4.1 5
0 8
1
40.4 ft=
0
0
0.3
0
5/4/2021 7:07 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing Solar
Below
12 N=>S Exterior Concrete Block -Int lnsul KITCHEN 4.1 35 8
13 N=>S Exterior Concrete Block- Int lnsul STORAGE 4.09999 6 8
14 N=>S Exterior Concrete Block- Int Insul STORAGE 4.09999 5 8
15 N=>S Garage Frame - Wood MASTER BE 11 30 8
1 282.9 fF
48.0 ft2
40.0 ft2
0 240.0 fF
0 0 0.3
0 0 0.3
0 0 0.3
0 0.23 0.3
0
0
0
0
DOORS
# Omt DoorType
Space Storms
U-Value Width Height
Ft In Ft In
Area
1 E=>W Insulated
KITCHEN None
.32 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V # Omt ID Frame Panes
NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation ImShade
Screening
1 W=>E 2 Metal Low-ESingle
2 W=>E 4 Metal Low-ESingle
3 N=>S 6 Metal Low-ESingle
4 W=>E 7 Metal Low-ESingle
5 S=>N 8 Metal Low-ESingle
6 EaW 10 Metal Low-ESingle
Yes 1.02 0.29 N
Yes 1.02 0.29 N
Yes 1.02 0.29 N
Yes 1.03 027 N
Yes 1.02 029 N
Yes 1.02 0.26 N
32.4 f? 1 ft 5 in
18.4 ft2 1 R 5 in
18A ft2 1ft5in
40Z ft2 12 ft0 in
6.9 ft2 1 ft 5 in
12.8 1`12 1 ft 5 in
1 ft 5 in None
1 ft 5 in None
1ft5in None
1ft5in None
1 ft 5 in None
1 ft 5 m None
None
None
None
None
None
None
GARAGE
# FloorArea CeilingArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 280 ft- 280 ft2 35 ft
8.1 ft
11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgI-A ACH
ACH 50
1 Wholehouse ProposedACH(50)
.000257 867.2 47.58 89.32 .0907
5
HEATING SYSTEM
# System Type
Subtype Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split Single HSPF:8.2
27 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split Single SEER: 14
29 kBtu/hr
cfrn 0.8 1
sys#1
5/4/2021 7:07 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
Se1Pnt
Conservation
1 Electric
Tankless
Garage
0.6
1gal
60.9 gal
120deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart# CompanyName
System Model# Collector Model#
Area Volume
FEF
None None
ft'
DUCTS
—Supply----
—Return
Air
CFM25
CFM25
HVAC#
V # Location R-Value Area
Location
Area
LeakageType
Handler
TOT
OUT ON RLF
Heat Cool
1 Attic
6 120 ft'
Attic
45 ft-
DefaultLeakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: N
Ceiling Fans:
cooling Jan Feb
Venting Jan Feb
Mar
Mar
r Apr
Apr
r[]] May
Jun [[�] Jul
n Jun
[[�] Aug(j�j
Se
Oct (r7(')Nov
Dec
[ 1 May
I 1 Jul
l l Aug
[ ] Sep
Oct [X]
Nov
Dec
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD)
78
78
78
78
PM
78 78
78
78
78 78
78
78
Cooling(WEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating(WD)
68
68
68
68
PM
68 68
6S
68
68 68
68
68
Heating(WEH) AM
68
68
fib
68
68 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
FumitureFraction
Space
Default(8lbs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8lbs/sq.ft.
ft2
It
0.3
DEN
Default(8lbs/sq.ft.
ft'
it
0.3
SINK AREA
Default(8lbs/sq.ft.
ft'
it
0.3
CLOSET
Default(8 lbs/sq.ft.
it-
it
0.3
GREAT ROOM
Default(8lbs/sq.ft.
ft'
it
0.3
MASTER BATH
Default(Slbs/sq.ft.
ft'
ft
0.3
POWDER
Default(8lbs/sq.fL
w
it
0.3
KITCHEN
Default(81bs/sq.ft.
ft'
It
0.3
LAUNDRY
Defaul 8 1bs/sq.ft.
0 ft2
Oft
0.3
STORAGE
5/4/2021 7:07 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 5
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE BUIDDING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL. Permit Number:
v
Owner: WYNNE BUILDING CORP. Jurisdiction:
ul
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealingmaterial.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ed ceiling/soffit
Y
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking,or floor framing cavity insulation
and cantilevered
e9
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawispace wall
.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind nipino an wirino
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
......,, vywuvu v, ,vy .ro,u ai loll vc n i auuuivai wl, wiui Lill, fnuvialuuJ ul I ,,- uu.
5/4/2021 7:08 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 95
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst rase?
6. Conditioned floor area (ft2)
7. Windows** Description
a. U-Factor: Sgl, U=1.02
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.03
SHGC: SHGC=0.27
c. U-Factor. Sgl, U=1.02
SHGC: SHGC=0.26
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-Factor(AVG): N/A
SHGC(AVG): N/A
THE COTTAGE, FT. PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1478.30 ft'
b. Frame- Wood, Adjacent
R=11.0
240.00 ft2
1
c. N/A
R=
ft2
1
d. N/A
R=
ft2
Yes
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1285.00 ft2
1285
b. Knee Wall (Vented)
R=19.0
30.00 ft2
Area
c. N/A
R=
ft2
76.04 ft2
12. Ducts, location & insulation level
R ft'
a. Sup: Attic, Ret: Attic, AH: Attic
6 120
40.00 ft2
13. Cooling systems
kStu/hr
Efficiency
12.85 ft2
a. Central Unit
29.0 SEER:14.00
ft2
4.701 ft.
0.281
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1285.00 ft2
b. N/A R= ft2
c. N/A R= ft2
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code com is r `
Builder Signature: Date:
Address of New Homer ��q ��� S � City/FL Zip-:
kBtu/hr Efficiency
27.0 HSPF:8.20
Cap: 1 gallons
EF: 0.6
None
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/4/2021 7:07 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
+ wdghtsoft Project Summary Job:
,
Entire House BY
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORTPIERCE, FL34W Phire: 772-066-6799 Email: QUICKCALCSr`agOLCOM
Promect Information
For. WYNNE BUILDING CORP.
THE COTTAGE, FT. PIERCE, FL
��k
Notes:
Design
Weather. Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42
OF
Outside db
90
OF
Inside db 70
OF
Inside db
75
OF
Design TD 28
OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
grflb
Heating Summary
Sensible Cooling Equipment Load
Sizing
Structure 16269
Btuh
Structure
15484
Btuh
Ducts 3953
Btuh
Duds
5176
Btuh
Central vent (0 cfm) 0
Btuh
Central vent (0 cfm)
0
Btuh
none
(none)
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipmentload 20222
Btuh
Use manufacturers data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
19627
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
2067
Btuh
Ducts
1501
Btuh
Central vent (0 cfm)
0
Btuh
Heatingg
Area(M
Coolingg
(none)
1285
1285
Equipment latent load
3567
Btuh
Volume (tt) 10409
10409
Airchanges/hour 0.45
0.23
Equipment Total Load (Sen+Lat)
23195
Btuh
EquivAVF(cfin) 78
40
Req. total capacity at 0.70 SHR
2.3
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Carrier
Make Carrier
Trade CARRIER
Trade CARRIER
Model CH14NBO3000GOA0
Cond CH14NBO3000GOAD
AHRI ref 9162387
Coil FX4DNBO43L
AHRI ref 9162387
Efficiency 8.2
HSPF
EfBcfency 11.5 EER,14
SEER
Heating input
Sensible cooling
20300
Btuh
Heating output 28000
Btuh @47-F
Latent000ling
8700
Btuh
Temperature rise 26
OF
Total cooling
29000
Btuh
Actual airflow 967
cfm
Actual airflow
967
dim
Airflowfador 0.048
cfm/Btuh
Airflowfactor
0.047
clm/Btuh
Static pressure 0.50
in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.85
Capacity balance point = 34 OF
Backup:
Input=5kW, Output= 18005 Btuh, 100 AFUE
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
-* wrig7tsoW 2021-May-0406:58:58
RigkSule@Uiversa1201919.021 RSU08101 Page 1
...oft HVAQWYNNEBUIDLING-THECOTAGE-1285GL.mp Calc=MI8 FrordWorfares SW
wrightsoft- Right-M) Worksheet Job:
Entire House By.
QUICK CALCS, INC. sy.
317 ST. LUOIE LANE, FORTPIERCE, FL34946 Phore: 772466.6799 EMail:QUICKCALCS AOLOOM
1
Room name
ErOre House
MASTER BEDROOM
2
E1posed wall
145.0 It
31.0 It
3
Room height
8.1 ft
8.1 It heat) c l
4
Room dimensions
13.0 x 18.0 It
5
Roanarea
1285D iF
234D f
Ty
Consruclion
U-value
Or
HTM
Area (F)
Load
Area (11')
Load
number
(BWhW-*n
(Bbw
or perimeter (ft)
(Btuh)
or perimebr (it)
(BWh)
Hwt
Cool
Gros
Npr.
Heat
Cool
Grote
N/Pr5
Heat
Cad
6
-
Y--C
13A4o s
0.143
n
4A0
2.19
446
427
1710
934
0
0
0
0
2glaig,droutr,
1D40
n
29.12
21.68
18
0
537
400
0-
0
0
0
13h4as
0.143
a
4D0
2.19
162
129
516
282
0
0
0
0
2 ,droutr,
-
1D40
a
29.12
39.42
13
2
368
498
0
0
0
0
11
11b0
0390
a
10.92
10.34
20
20
223
211
0
0
0
0
t—G
13AAo s
0.143
's
- 4D0
219
2B4
277
1107
- 605
146
146
- 584
- 319
2glaang,droutr,
1.040
s.
29.12
21M
7
7
202
150
0
0
- 0
0
y/
13AAM
0.143
w
4D0
219
284
192
767
419
105
73
291
159
1Ac1om
1270
w
3556
34.77
41
41
1451
1419
0
0
0
0
1A-hlom
1270
w
3556
61.76
18
3
656
1139
0
0
0
0
1�.--,GG
1A411am
1270
w
3556
63.40
33
5
1162
2072
33
5
1162
2072
C
16C-30m1
0D32
--
0.90
128
- 1285
1285
1151
1645
234
234
- 210
300
F
22A-0
0.989
-
27.69
0.00
1285
145
4015
0
234
31
858
0
6
c)AED e=rsion
1
3591
1
997
Envelope lossigain
13867
13366
3105
3847
12
a) Infilbation
2402
658
514
141
b) Roomvenfilalion
0
0
0
0
13
Inlemalgainv O=panb@ 230
2
460
0
0
Applianoeslobler
1000
0
Sublotal(lirxs61013)
16259
15484
3618
3987
Less exbmal load
0
0
0
0
Lesstansfer
0
0
0
0
Redishib0on
0
0
0
0
14
Subtotal
16269
15484
3618
3987
15
Dud Wads
24%
33%
3953
5176
24%
33%
819
1336
Total roan bad
20M
20660
4498
5323
Airrequired(dm)
967
967
2151
249
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
,� 4* M,µ17 f ^' 2021-May-0406:58s8
A% RigttStita@ Wversa1201919.021 RSU08101 Page 1
..aft HVAC1WYNNESUIDLING-TFECOTTAGE-1285GLnp Calc=M18 FroftDoonaoes:SW
wrightssaft' Right-JO Worksheet job:
Entire House Date:
QUICK CALCS, INC. By
317 ST. LUCIE LANE. FORT PIERCE, FL34946 Plum: 772-466fi799 Eeell:QUICKCALCS@AOL.COM
1
Rcom nave
DEN
SINKAREA
2
Exposedxall
23.0 ft
7D ft
3
Room height
8.1 ft teatbDol
8.1 it heatbool
4
Room dimendons
11.0 x 12D ft
6.0 x 7.0 ft
5
Rom area
132D If
42.0 1F
Ty
Construction
U-%aloe
Or
HTM
AreaLoad
Am
number
(BWMF-°F)
(BtuhAF)
or perimeter (ft)
(BWh)
or perime� (1U
(BWh)
Heat
Cool
Gros
WAS
Heat
Cool
Gros
NIPS
Heat
Cod
6
W
13A-4ac
M143
n
4.00
2.19
97
97
389
213
0
0
0-
0
l—C
2glaarg,droutr,
1D40
n
29.12
21J58
0
0
0
0
0
0
0.
0
Vd
13A4=
0.143
a
4D0
2.19
0
0
0
0
0
0
0
0
L�DG
2 Wng,droutr,
1D40
a
29.12
39A2
0
0
0
0
0
0
0
0
11
11D0
0390
a
1092
10.34
0
0
0
0
0
0
0
0
Y}/
13A-4ots
0.143
s
4.00
2.19
0
0
0
0
57
57
227
124
2gWrig,droW,
1D40
s
29.12
21.68
0
0
0
0
0
0
0
0
--G
13A4ocs
0.143
w
400
2.19
89
71
283
155
0
0
0
0
1Ac1om
1270
w
3556
34.77
0
0
0
0
0
0
0
0
1AJ11om
1270
w
3556
61.76
18
3
656
1139
0
0
0
0
1Ah1om
1270
w
3556
63.40
0
0
0
0
0
0
0
0
C
16C30m1
OD32
-
090
128
132
132
118
169
42
42
38
- 54
F
22A•1pi
0389
-
27.69
Om
132
23
637
0
42
7
194
0
6
C)AlDexausal
575
.3
FJndopelostOn
2083
2250
459
175
12
a) Infiltration
381
104
116
32
b) Roanvenilation
0
0
0
0
13
Infemel gaily O=panls@ 230
0
0
0
0
Appliwoesbtier
0
0
Subtotal (firm to 13)
2464
2355
574
207
Lesex@mial loco
0
0
0
Lestarafar
0
0
0
Redistribution
n2464
0
0
0
14
Subfola1
235574
207
15
Drwthads
24%
33
789
24%
33%
140
Total room load
3063
31Q
714
276
A'vrequiletl (dm)
146
147
34
13
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
zozl-Ma os56�e
ECOTrAGE-1285G np Ca.021RSU08101 Paget
...oftHVAC\WYNNE BUIDLING-hiE COTTAGE-1285 GLnp CaIc=MIB Front0oorfdces:SW
1 wrigwaofr Right-M Worksheet Job:
Entire House Date:
QUICK CALCS, INC. sy.
317 ST. LUCIE LANE, FORTPIERCE, FL34946 Phore: 772466-6799 EmaiI:QUICKCA.LCS@A0L.00M
1
Room name
CLOSET
GREAT ROOM
2
EVosedmill
0 ft
33.0 ft
3
Room height
8.1 It heaY=I
8.1 It heatlmol
4
5
Room dimensions
Roomarea
9.0 x 7.0 It
63.0 T
1.0 x 452.0 It
452D ft°
Ty
Conshuction
U-value
Or
HTM
Area
Load
number
(BWh4F-'F)
(Bwhm)
or perimeter (ft)
(BWh)
oorPerime�ter (ft)
(Btih)
Heat
Cool
Gros;
NIPS
Heat
Cool
Gross
WP/S
Heat
Cool
6
M/
13A4a
0.143
n
4.00
2.19
0
0
0
0
178
160
640
350
1—C
U+1
2gaarg,droutr,
13A4a
1.040
0.143
n
a
29.12
4A0
21.68
2.19
0
0
0
0
0
0
0
0
18
0
0
0
537
0
400
0
11
2glaang,droutr,
1100
1.D40
0.390
a
a
29.12
10.92
39.42
10.34
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1�—(G
Ur/
13A-4=
2glaarg,drouT,
13AAo
0.143
1A40
0.143
s
s
w
4.00
29.12
4.00
2.19
21.66
2.19
0
0
0
0
0
0
0
0
0
0
0
0
0
0
89
0
0
48
0
0
193
0
0
106
—G
tAalom
1270
w
3556
34.77
0
0
0
0
41
41
1451
1419
IA-hlom
1270
w
35.56
61.76
0
0
0
0
0
0
0
0
C
to-hlom
16CS0ml
1270
0.032
w
-
3556
0.90
63.40
128
0
63
0
63
0
56
0
81
0
452
0
452
0
405
0
579
F
22A-tpI
0.989
-
27.69
0.00
63
0
0
0
452
33
914
0
6
c)AEDe=rslon
-1
2068
Ewelope lossfon
156
801
4140
4921
12
a) Infiltradon
0
0
547
150
b) Roomvenfiladon
0
0
0
0
13
Intemal gaire: Omlpants@ 230
0
0
2
460
AppiianoeNother
0
0
Sublotal(lines6t113)
56
80
4687
1530
Lesexdemalloao
0
0
0
0
Lesstransfer
0
0
0
0
14
Redistribution
Subtotal
0
56
0
80
0
4687
0
5530
15
Dudloads
24A
33%
14
27
24%
33%
1139
1852
Total room load
Air required(dm)
70
3
106
5
5825
2791
7383
346
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
-ro- war9hssore` 2021-Nay-0406:58:56
�c� RigttSufeO+ lhiversa1201919.021 RSU08101 Page 3
...cRWACIWYNNESUIDLING-THECOTrAGE-1285GL.np CaIc=WB Frord DoorfarQs:SW
wrightsott- Right-J@ Worksheet Job:
Entire House DOW`
QUICK CALCS, INC. By.
317 ST. LUCIE LANE, FORT PERCE, FL34946 Phore: 772-466-6799 EnaiI:OUIGCCALCS@AOL.COM
1
Room name
N14STER BATH
POWDER
2
Exposdwall
50 R
0 it
3
Room height
8.1 it heaVowl
8.1 it heatlmol
4
Rom dmensiom
10.0 x 5D 8
50 x 5.0 it
5
Romn area
50.0 if
25D T
Ty
Cordhiction
U-value
Or
HTM
Area (fly
Load
Area (t)
Load
number
(Bbh4l;*n
or penmeter M
(Btuh)
or perimeter M
(BWh)
Heat
Cool
Gross
IWPfS
Heat
Cool
Gros
NIPS
Heat
Cool
6
W
13A4as
0.143
n
4.00
2.19
.0
0
0
0
0
0
0
0
�G
2glaang,droutr,
1.040
n
29.12
21.68
0
0
0
0
0
0
0
0
W
13A-4=
0.143
a
400
2.19
0
0
0
0
0
0
0
0
I:G
2glaang,droutr,
1040
a
29.12
39A2
0
0
0
0
0
0
0
0
11
11DO
0390
a
10.92
10.34
0
0
0
0
0
0
0
0
—D
W.
LC
13AAM
0.143
s
4.DO
2.19
41
34
134
73
0
0
0
0
2glaarg.droutr,
1040
s
29.12
21.68
7-
7
202
150
0
0
0
0
V�1
13A-0ors
0.143
w
400
2.19
0
0
0
0
0
0
0
0
�C
1A-dw
1-7m
w
3556
34.77
0
0
0
0
0
0
0
0
IL —CC
Whom
12M
w
3556
61.76
0
0
0
0
0
0
0
0
tAhlom
1270
w
35M
63-40
0
0
0
0
0
0
0
0
C
16C-80ml
UK
-
090
128
50
50
45
64
25
25
22
32
F
22"
0989
-
27B9
000
50
5
138
0
25
0
0
0
6
c)Amexa¢aon
-4
0
6nelope losagain
520
284
22
32
12
a) Irifiltra5on
83
23
0
0
b) RoomlerNlalon
0
0
0
0
13
Internal gains: Omlpan5@ 230
0
0
0
0
Applianordother
0
0
Subbml Qinesfito13)
602
306
22
32
Lese&malioad
0
0
0
0
Leshansfer
0
0
0
0
RedWbuhon
0
0
0
0
14
Subtotal
602
306
22
32
15
Ductloads
24%
33%
146
103
240A
33%
5
11
Total room load
749
409
28
42
Airre9tored (dm)
36
19
1
2
Calculations approved bvACCAto meet all requirerneMs of Manual J 8lh Ed.
wrl9htsotR^ 2021-May-0406:5BM
RigttSdte®lkivers1201919.021 RSW8101 Page
...oft HVAaWYNNE BUIDLING-7FE COTTAGE-12B5 GL.rp Calc=MIA Frort Doorfares SW
>{� wrightsoft- Right-JO Worksheet Job:
Entire House °fit
QUICK CALCS, INC. BY
317 ST. LUCK LANE, FORTMERCE, FL34M Phn :772-4666799 Email: QUICKCALCS@AOL.COM
1
Room name
KRCHEN
LAUNDRY
2
Expowdx%ell
38.0 ft
0 ft
3
Fa a height
8.1 ft heaUcad
8.1 ft heabbool
4
Room dim risons
10 x 223D ft
4.0 x 100 ft
5
Room area
223.0 ff
40.0 ff
Ty
Construcfion
ll-wiue
Or
HTM
Area
Load
ALM(ff�
Load
number
I
(BU MP-*9
(EMW
or perimeter (ft)
(fiWh)
or penme4+s (ft)
fth)
Halt
Cool
Grow
NrPS
Heat
Cod
Gross
NrPS
Heat
Cool
6
W
13A-4als
0.143
n
4A0
- 2.19
138
138
551
301
- 0
0
0
- 0
LG
2gkdng,droutr,
1.040-
n
29.12
21A
0-
0
0
0
0-
0
0
0
Yy y13A4ocs
0.143
a
4A0
2.19
130
97
387
211
0
0
0
0
fl----DG
2glaarg,droutr,
IA40
a
29.12
39.42
13
2
368
498
0
0
0
0
11
11DO
02W
a
10.92
10.34
20
20
223
211
0
0
0
0
W
L—C
134-0as -
0.143
s
4A0
Z19
41
41
162
89
0
- 0
0
0
2glaang,droutr,
1.040
s
29.12
21M
0
0
0-
0
0
0
0
0
4y
1A-c1w
w
0
0
0
0
0
0
0
0
IIL—_--GGG
1270
1270
w
3556
5-%
4.77
0
0
0
0
0
0
0
0
%h1w
1A-h1om
1270
w
3556
61.76
61.76
0
0
0
0
0
0
0
0
to-hlom
12M
w
3555
63A0
0
0
0
0
0
0
0
0
C
16G30m1
OA32
-
0.90
128
223
223
200
285
40
- 40
36
51
F
22A-011
0289
-
2759
0.00
223
38
1052
0
40
0
0
0
6
c)AEDexasson
37
_1
EmAdope loWgain
I2943
1559
36
51
12
a) hfiltralion
630
172
0
0
b) Room w filation
0
0
0
0
13
Intemalgaim Omrpan5@ 230
0
0
0
0
Appliarimslother
1000
0
Subfolal(lims61o13)
3573
2731
36
51
Leweldemd load
0
0
0
0
Lewtransfer
0
0
0
0
RedishibLdw
0
0
0
0
14
Submfal
3573
2731
36
51
15
Dudloatls
249/6
33%
868
915
24%
339(
9
17
Total mom load
3646
45
67
Air regwred(dm)
212
171
2
3
Calculations approved byACCAto meet all requirements of Manual J Sth Ed
2021-May0406:58M
R9OT'rAG .1285GL.np919.021 B Fror01 Pages
._oltHVAC1WYNNE BUIOLINGhIE COT(AGE-7285 GL.np CaIc=MB Fmd Doorfaces:SW
TAAJ F wr3ghwow Right-J® Worksheet Joe
Entire House Dfit
QUICK CALCS, INC. By.
317 SL LUCIE LANE, FORT PIERCE, FL34946 Phor :772-466£799 Email: OUICKCALCS@AOL.COM
1
Room name
STORAGE
2
EVosedvall
8.0It
3
Room height
8.1 it heatl000l
4
5
Room dimensions
Room area
4.0 x 6.0 It
24.0 fF
Ty
Corstiudion
number
U-value
(BWhW-'9
Or
HTM
(BtuhM�
Area
or perimeter (ft)
Load
(BWh)
Area
or perimeter
L
Heat
Cool
Gross
NIPS
Heat
Cool
Gross
NIPS
Heat
Cool
6
VII
�G
13A-0as
2glaarg,droutr,
13A-4=
0.143
1.040
0.143
n
n
a
4.00
29.12
4.00
2.19
21.68
2.19
32
0
32
32
0
32
130
0
130
71
0
71
V /
11
I�—D�
2glaang,droutr,
11DO
13A4ors
2glaang,droutr,
13AAocs
1.040
0.390
0.143
1.040
0.143
a
a
s
s
w
29.12
10.92
4.00
29.12
4A0
39.42
10.34
2.19
21.68
2.19
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-
VN
I—C
1Aclam
1A-hlom
1270
1270
w
w
3556
3556
34.77
61.76
0
0
0
0
0
0
0
0
C
1A-htom
16C-30mi
1270
0.032
w
-
3556
0.90
63.40
128
0
24
0
24
0
22
0
31
F
22A-tpl
0.989
-
27.69
0.00
24
8
222
0
6
c)AIDe=ulson
3
Envelopeloss/gain
502
170
12
a) Infiltration
133
36
b) Roomsentilation
0
0
13
Intemalgains: Ooupants@ 230
0
0
Applian ardother
0
Subbtal(linesfito13)
IM
206
Les e»mal load
0
0
Lestransfer
0
0
RedL*ibuScn
0
0
14
Sublotal
635
206
15
Dud loads
24%
290/.
154
59
Totai room load
789
265
Air required(cfm)
38
12
Calculations approved bvACCA to meet all reauirements of Manual J 8th Ed
...Ri1l .021 RSU08101 2021.Wy-0406:58:58
oftHVAGWMNESUIDLING-THEC07rAGE-1285GL.np Galc=vB FroNDoorh�sSW Page 6
. wrightsoW Duct System Summary o bate:
Entire House By.
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Ptnre: 772466.6799 Ema11:QU1CKCA1-CS@AO1-.COM
Project• •
For. WYNNE BUILDING CORP.
THE COTTAGE, FT. PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual airflow
Total effective length (TEL)
Heating
0.50
in H2O
0.28
in H2O
0.22
in H2O
0.110/0.110
in H2O
0.080
in/100ft
967
cfm
126
Supply Branch Detail Table
Cooling
0.50
in H2O
0.28
in H2O
0.22
in H2O
0.110/0.110
in H2O
0.080
in/100ft
967
cfm
Name
Design
(Btuh)
Htg
(Cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
CLOSET
c 106
3
5
0.080
4.0
Ox0
VIFx
24.6
90.0
st1
DEN
c 3143
146
147
0.080
7.0
Ox0
VIFx
33.5
90.0
st1
GREATROOM
c 3691
139
173
0.080
8.0
OxO
VIFx
14.6
70.0
GREATROOM-A
c 3691
139
173
0.080
8.0
OxO
VIFx
16.1
70.0
KrrCHEN
h 4441
212
171
0.080
7.0
OxO
VIFx
4.5
70.0
LAUNDRY
c 67
2
3
0.080
4.0
OxO
VIFx
5.4
70.0
MASTERBATH
h 749
36
19
0.080
4.0
OxO
VIFx
32.9
90.0
st1
MASTER BEDROOM
c 2661
108
125
0.080
7.0
OXO
VIFx
27.9
90.0
SO
MASTERBEDROOMA
c 2661
108
125
0.080
7.0
Ox0
VIFx
35.9
90.0
st1
POWDER
c 42
1
2
0.080
4.0
Ox0
VIFx
29.2
90.0
SO
SINKAREA
h 714
34
13
0.080
4.0
Ox0
VIFx
30.9
90.0
st1
STORAGE
h 789
38
12 1
0.080
4.0
Ox0
VIFX
11.2
70.0
Supply Trunk Detail Table
Name
Trunk
Type
Htg
(cfin)
Clg
(cfm)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Dud
Material
Trunk
st1
PeakAVF
436
435
0.080
555
12.0
0 x 0
VinIFIX
Wfl�7tSOft' 2021-May-0406S859
�„ -- ......- mow.,.«, RigH-SdR Unv .1201919.021 RSU08101 Page 1
,4DM...oft HVAQWYNNE BUIDLING-THE COTTAGE-1285 GL.W Calc=W8 FrorQDoOrfaces:BW
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(dM)
cIg
(Cfm)
TEL
(it)
Design
FR
Woc
(fpm)
Diam
(in)
H x W
(n)
Stud/Joist
Opening (in)
Dud
Mat
Trunk
rbl
Ox0
967
967
0
0
0
0
Ox 0
1
VIFx
mtL® 2f127-�y 0 08:58s9
RigFk dU Urivatsa1201919A21 RSW8101 Page
...oRWAC1WYMJEBUIDLING-THECOTTAGE-1285GL.np Calc=NW FrortDmrfa ,SW