Technical Data Sheet CeftinTeed
WinterGuard®HT Waterproofing Underlayment SAINTGOBAIN
WinterGuard®Sand Waterproofing Shingle Underlayment
WinterGuard�Granular Waterproofing Shingle Underlayment
NOTE: Reference to WinterGuard without specific reference to HT, Sand or Granular relates to all three
products.
PRODUCT INFORMATION
WinterGuard products are most commonly used in critical areas such as roof eaves, valleys, and as a
waterproofing underlayment for low -slope shingle, metal (HT only), slate, and mechanically -fastened tile
roofing applications. WinterGuard HT (High Tack, High Temperature) is an advanced waterproofing
underlayment for shingle, metal, slate and tile roofs. It is specially formulated to resist high roof
temperatures under metal roofs. WinterGuard Sand and Granular underlayments are designed for use
on roof decks as a waterproofing barrier beneath shingle, slate and tile roofs to prevent leakage due to
water back-up from ice dams or wind -driven rain.
Limitations:
• Do not expose WinterGuard permanently to sunlight. Cover WinterGuard as soon as possible
with a permanent roof surface. The maximum exposure time is six (6) months.
• WinterGuard will not adhere to wet or cold surfaces. For cold weather tack down, use only roofing
nails. Under no circumstances should staples be used with WinterGuard products. Refer to
instructions on the carton for additional nailing and sealing instructions.
• Do not apply WinterGuard over shingles or underlayment of any sort.
• WinterGuard is a vapor barrier. Therefore, if WinterGuard is applied over a majority of the roof
deck, proper deck ventilation must be provided.
• If WinterGuard must contact sealants or cements, use solvent -based products sparingly, following
manufacturer's instructions carefully. Excessive use of solvent -based adhesives can damage
WinterGuard's polymer modified asphalt coating. Do not use silicone -based sealants, as they do
not maintain adequate long-term adhesion to asphalt.
• Low -slope application: WinterGuard HT can be applied beneath shingles, slate and mechanically -
fastened tile to acceptable decks with slopes of 2"/12" or greater and beneath metal to acceptable
decks with slopes of 0.5"/12" or greater. WinterGuard Sand and Granular products can be applied
beneath shingles, slate and mechanically -fastened tile to acceptable roof decks with slopes of
2"/12" or greater. See grid below for minimum allowable slopes.
• WinterGuard HT is specially designed to withstand temperatures up to 250°F.
• WinterGuard may become slippery under certain weather conditions. When this occurs, avoid
walking or crawling on the product.
WINTERGUARD — MINIMUM ALLOWABLE APPLICATION SLOPES
Applied Beneath
WinterGuard HT
WinterGuard Sand
WinterGuard Granular
SHINGLES
2712"
2"/12"
2"/12"
METAL
0.5/12"
Not Recommended
Not Recommended
TILE
2"/12"
2"/12"
2"/12"
SLATE
2'712"
2"/12"
2"/12"
Product Composition:
WinterGuard is a self -adhering waterproofing membrane composed of a tough reinforcement that is
impregnated and coated with SBS-modified asphalt. WinterGuard is available in three finishes: sand,
granular, and film. WinterGuard Sand and Granular have top surfaces consisting of mineral matter (sand
or granules) to enhance traction during application. WinterGuard HT has a tough, tear resistant film on its
top surface that won't scratch metal roofing applied over it. The adhesive bottom surface of all
WinterGuard products is protected with a disposable silicone -coated release film, which is split
longitudinally down the middle for easier application.
Technical Data Sheet
WinterGuard Series
Applicable Standards: ASTM D 1970
ICC ESR-1492 Florida Product Approval # FL 11288
Miami -Dade Product Control Approved CSA A123.22
UL 790: Classified for use as underlayment beneath Class A, B, or C fire rated shingle systems
WinterGuard Products by Surface Finish
PHYSICAL DATA
Roll Areas .ft.
Sand
short
Sand
Granular
HT (film)
97.5
195
195
195
Roll Length ft.
32.5
65
65
65
Roll Width ft.
3
3
3
3
Thickness mils.typical)
60
60
60
45
Side Laps in.
6
6
4
4
End Laps in.
6
6
6
6
Shipping Weight (approx. lb/roll)
36
68
68
51
Packaging (cartons/pallet
30
20
20
20
TECHNICAL DATA
Per ASTM D1970 ASTM Test
Maximum Load at Break
MD D2523
CMD
Elongation at Break D2523
Modified Bitumen Portion
Requirement
Granular
Sand
HT film
> 25 Ibf/in
Pass
Pass
Pass
Pass
Pass
Pass
> 10%
—
> 12 Ibf/ft
Pass
Pass
Pass
Pass
Pass
Pass
Adhesion to Plywood 75°F
D903
Thermal Stability
D1204
< 3 mm
Pass
Pass
Pass
Flexibility Temperature
D1970
Pass @ -20°F
Pass
Pass
Pass
Tear Resistance
MD
CMD
D4073
E96
> 201bf/in
< 0.1
Pass
Pass I
Pass
Pass
Pass
Pass
Moisture Vapor Permeance
Pass
Pass
Pass
Sealability Around Nail
D1970
No Leakage
Pass
Pass
Pass
Watetproof Integrity of Las
D1970
No Leakage
Pass
Pass I
Pass
INSTALLATION
Storage: Store WinterGuard rolls in their packaging in a dry, protected area at a temperature not
exceeding 110°F.
Page 2 of 3
Deck Preparation: Clean the roof deck until it is free of dirt, dust, nails, and other materials. Providing a
clean, dry and smooth deck surface is important to assure proper adhesion of the WinterGuard to the
deck. Before application to existing roofs, remove all roofing materials including the roofing felt and nails.
Priming: Priming is not necessary for clean and dry wood decks. Concrete and masonry deck surfaces
and oily metal surfaces require priming with an asphalt primer meeting ASTM D 41 standards, such as
CertainTeed's FlintPrimeTm, or equivalent. Before WinterGuard is applied, primer must be dry. Follow
manufacturer's instructions for the application of the primer.
Membrane Application at the Eaves for Ice Dam Protection: WinterGuard can be applied in any length
convenient to the applicator. First, align unrolled material with lower edge of roof and hold in place. Lift
starting end of material approximately 1 foot, peel back and fold under at least 6 inches of both sheets of
protective release film. Carefully return the exposed adhesive surface to the deck and press firmly in
place. If, at lower temperatures, the material does not adhere immediately, tack it in place with roofing
nails. Under no circumstances should staples be used with WinterGuard products. Reroll material from
the other end until the peeled and folded back film is exposed.
Technical Data Sheet
WinterGuard Series Page 3 of 3
Beginning with the folded back film, peel both sheets of the remaining film from the roll, pulling parallel to
the eave. Be sure all material lays flat without wrinkling and is well adhered.
Alternatively, apply by the "peel and flop" method, utilizing the two-piece split -sheet release film feature to
adhere longitudinal halves, one at a time. It is best to cut the product into manageable lengths of about 10
feet when applying WinterGuard by this method.
Applying WinterGuard is strongly recommended wherever there is a possibility of ice build-up. Many
building codes require that the upper edge of ice dam protection extend no less than 24 inches beyond
the interior wall line of the exterior walls. In areas of severe icing, it is recommended that WinterGuard be
applied at least up to the highest water level expected to occur from ice dams. In order to assure
waterproofing, overlap all membrane side laps and end laps per Technical Data table above, press all
overlaps firmly with a membrane seam roller, and offset end laps at least 2 feet from course to course.
Application of Drip Edge at Rakes and Eaves: At the rake, the drip edge may be installed under or
over WinterGuard. At the eaves, when the WinterGuard does not overlap the gutter or fascia, the drip
edge should be installed under WinterGuard. At the rake or eaves, when WinterGuard overlaps the gutter
or fascia, drip edge or other metal must be installed over the WinterGuard to protect it against damage
from exposure.
Low -Slope Shingle, Metal, Shake, or Tile Application: WinterGuard can be applied under these roofing
materials to provide protection against the infiltration of wind -driven rain on low -slope applications. If
applied to cover the entire roof, ensure sufficient ventilation to avoid condensation. WinterGuard HT can
be applied beneath shingles, slate and mechanically -fastened tile to acceptable decks with slopes of
2"/12" or greater and beneath metal to acceptable decks with slopes of 0.6712" or greater. WinterGuard
Sand and Granular products can be applied beneath shingles, slate and mechanically -fastened tile to
acceptable roof decks with slopes of 2"/12" or greater.
Application at Valleys and Ridges: In the valleys, the width of the WinterGuard must be 36 inches
minimum, and on the ridges, 12 inches minimum. Cut WinterGuard to convenient premeasured lengths (4
to 6 feet recommended). Peel off the release film and drape the sheet into place, allowing the membrane
to locate and adhere in the valley centerline or ridge peak first, working outward toward the edges. In
valleys, start the application at the low point and work upwards. To assure waterproofing, overlap all
sheets 6 inches at lap joints. Do not use WinterGuard as a permanent weathering surface (such as in an
open valley).
MAINTENANCE
WinterGuard requires no maintenance when installed according to manufacturer's application
instructions.
WARRANTY
WinterGuard is warranted against manufacturing defects and to remain watertight for the same period as
the warranty duration carried by the roofing product applied above it — up to a maximum of 50 years. For
specific warranty details and limitations, refer to the warranty itself.
FOR MORE INFORMATION
Sales Support Group: 800-233-8990
Web site: www.certainteed.com
CertainTeed Roofing
20 Moores Road
Malvern, PA 19355
© Copyright CertainTeed Corporation, 2016 CartainTeed
All rights reserved. Updated: 12/2016 SAINT GoaAiN
MIAM in
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (NO
CertainTeed Corporation
20 Moores Road
Malvern, PA 19355
SCOPE:
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.mianddade.eov/econemv
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: CertainTeed Underlayment Systems
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA# 14-1028.02 and consists of pages 1 through 9.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 1 of 9
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category_: Underlayment
Material: SBS
SCOPE:
This approves CertainTeed Underlayment Systems, as described in this Notice of Acceptance; designed to comply with
the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Product
Specification Description
WinterGuard HT 36" x 65' ASTM D 1970 Modified fiberglass reinforced, bituminous sheet
Manufuring rolls material for use as an underlayment in sloped roof
Location #1 assemblies. Designed as an ice & rain shield.
WinterGuard Granular 36" x 65' ASTM D 1970 Granular surfaced modified, fiberglass reinforced,
Manufuring rolls bituminous sheet material for use as an
Location #2 underlayment in sloped roof assemblies.
Designed as an ice & rain shield.
'%0 erGu!�-d Sand 36" 65' AST 1970 Enib ddc- sand surface m dified, fiber - a
Manufuring
o rciufoi ,bituminous sh t material for a as an
Location #2 under^ eni in sloped r o sseniblies.
De.si ned as an ire & r shield.
Diamond Deck" 48" x 250' ASTM D 226 Synthetic, scrim reinforced underlayment for use
Manufuring rolls Type II under shake, shingles, slate or metal roofing.
Location #3& 4
MetaLaymenf" 39 3/s" x 61' ASTM D 1970 A film surfaced, self -adhering underlayment for
Manufuring rolls use under metal roofing.
Location #1
Black Diamon&" 39 3/s" x 68' 7" ASTM D 1970 Granular surfaced modified, fiberglass reinforced,
Base Sheet rolls bituminous sheet material for use as an
Manufuring underlayment in sloped roof assemblies.
Location #2 Designed as an ice & rain shield. Not for use as
an Anchor Sheet. Direct adhesion to wood deck
not permitted in the HVHZ.
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 2 of 9
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
Product Dimensions Test Product
Specification Description
Flintlastic GTA 39 3/8" x 32' 10" ASTM D 6222 Granule surfaced APP Modified Bitumen
Manufuring rolls Grade G membrane with non -woven polyester mat
Location #1 Type I reinforcement for torch application.
All Weather/Empire
Base Sheet
Manufuring
Location 91
Flintlastic GMS
Manufuring
Location #1
Flintlastic SA Cap
Manufacturing
Location #1
Roofers' Select
Manufacturing
Location #5
RoofRunner
Manufacturing
Location #6
39 3/8" x 65' 10" ASTM D 4601 Asphalt coated fiberglass reinforced base sheet.
rolls Type II
39 3/s" x 32' 10" ASTM D 6164 Granule surfaced SBS Modified Bitumen
rolls Grade G membrane with non -woven polyester mat
Type I reinforcement for mop application.
39 3/8" x 33' 11"
rolls
36" x 144' rolls
48" x 250 rolls
MANUFACTURING LOCATION:
1.
Little Rock, AR.
2.
Shakopee, MN
3.
Hangzhou, China
4.
Silvassa, India
5.
Shreveport, LA
6.
Vapi, India
TAS 103 Polyester reinforced, self -adhering SBS modified
bitumen cap sheet.
ASTM D226 An asphalt -impregnated, organic felt reinforced
Type I with glass fibers, roofing underlayment.
ASTM D226 Synthetic, scrim reinforced underlayment for use
Type II under asphalt shingles.
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 3 of 9
EVIDENCE SUBMITTED:
Test AF-eney
Test Identifier
Test Name/Report
Date
Momentum Technologies, Inc.
AX31G8G
ASTM D6222
06/05/09
TrinitylERD
3530.12.05-1-R1
ASTM D1623
10/05/09
C30280.12.09-R2
ASTM D226
12/11/09
C32240.03.10
ASTM D4977
03/04/10
C30890.03.10-1
ASTM D1970
03/17/10
C3500.04.10
TAS 103
04/01/10
C31860.05.10
ASTM D1623
05/18/10
C40050.09.12-2
ASTM D1970
09/28/12
C31410.10.10-R1
ASTM D5147. ASTM D4798
11/02/12
C45240.01.14-1
ASTM D1970, TAS 110
01/15/14
C32930.01.11-R2
ASTM D1623
01/20/14
C45240.01.14-2
TAS 103, TAS 110
01/24/14
CTR-SC11145.16-3A
ASTM D4601
09/19/16
CTR-SC11415.11.16
TAS 103
11/28/16
CTR-SC11505.12.16
ASTM D1623
12/22/16
ACT-SC14110.06.17-1
ASTM D 226
06/29/17
PRI Construction Materials
CTC-093-02-01
ASTM D6164, ASTM D4798
08/09/11
Technologies, LLC
CTC-163-02-01
ASTM D6757, ASTM D226,
05/09/13
ASTM D4869
InterTek Testing Services Ltd.
10103165000Q-002C
ASTM D226
08/13/13
101227796COQ-003C
ASTM D4798
08/13/13
10103165000Q-005C
ASTM D4869
08/13/13
QAI Laboratories
RJ3334-2
ASTM D226
07/07/14
RJ3502-1
ASTM E108
09/29/14
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 4 of 9
APPROVED ASSEMBLIES:
Deck Type l: Wood, Non -insulated
Deck Description: "/32" or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above) One or more plies of Diamond Deck with a minimum 4" headlap and a 6" end
lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge
and in a grid pattern spaced 12" o.c. in the field of the roll.
(2:12 to < 4:12) One or more plies of Diamond Deck with a minimum 20" headlap and a 12"
end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll. Vertical joints should be offset
36" minimum.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, and metal roof applications. Must Comply with applicable Roofing Application Standards
and Building Codes
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(2): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above) a single layer of RoofRunner shall be applied with printed side up, parallel to
the eaves, overlapping each course with a minimum 3" headlap and a 6" end lap mechanically
fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and spaced 15" o.c.
vertically and 12" o.c. horizontally in the field of the roll.
Surfacing: Shall be acceptable for use in approved asphaltic shingle applications. Must Comply with
applicable Roofing Application Standards and Building Codes
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 5 of 9
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(3): Anchor sheet mechanically fastened to deck.
Anchor Sheet: (4:12 or Above) Two plies of Roofers' Select with a minimum 2" headlap and a 6" end lap
mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and
in a grid pattern spaced 12" o.c. in the field of the roll.
(2:12 to < 4:12) Two plies of Roofers' Select with a minimum 19" headlap and a 12" end lap
mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and
in a grid pattern spaced 12" o.c. in the field of the roll. Vertical joints should be offset 72"
minimum.
Surfacing: Shall be acceptable for use in approved asphaltic shingle applications. Must Comply with
applicable Roofing Application Standards and Building Codes
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(4): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap
edge and in a grid pattern spaced 12" o.c. in the field of the roll.
Membrane: One or more plies of Flintlastic GTA torch applied to anchor sheet or WinterGuard HT,
WinterGuard Granular, WinterGuard Sand, MetaLayment or Black Diamond Base Sheet self -
adhering membrane adhered to the anchor sheet with a minimum 3" headlap and 6" end lap.
Place the first course of membrane parallel to the eave, rolling the membrane to obtain
maximum contact. Remove the release membrane as the membrane is applied. Vertical
strapping of the membrane is acceptable. If membrane is strapped, then anchor sheet must also
be strapped.
Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry
slate, and metal roof applications. Must Comply with applicable Roofing Application Standards
and Building Codes
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 6 of 9
Deck Type 1: Wood, Non -insulated
Deck Description: 19/32" or greater plywood or wood plank
System E(5): Anchor sheet mechanically fastened to deck, membrane adhered.
Anchor Sheet: One ply of ASTM D 226 Type I1 organic felt or All Weather/Empire Base mechanically
attached with a minimum 4" side lap and a minimum 6" end lap. Anchor sheet shall be applied
at a right angle (900) to the slope of the deck with approved annular ring shank nails and tin
caps at a fastener spacing of 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in
the field of the roll of the base sheet.
Ply Sheet: (Optional) One or more plies of an ASTM D226 ply sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Membrane: One ply of Flintlastic GMS adhered in a full mopping of Type IV asphalt applied within the
EVT range and at a rate of 20-40 lbs./sq. or Flintlastic GTA torch applied to the preceding sheet
or Flintlastic SA Cap, self -adhering membranes adhered to the preceding sheet with a minimum
4" side lap and 6" end lap. Place the first course of membrane parallel to the eave, rolling the
membrane to obtain maximum contact. Remove the release membrane as the membrane is
applied. Vertical strapping of the membrane is acceptable. If membrane is strapped, then
anchor sheet and ply sheet must also be strapped.
When used in Tile roof systems the cap sheet shall be back nailed to deck with approved
annular ring shank nails and tin caps at a maximum of 12" o.c. at the side laps and 6" o.c. at the
end laps. No nails or tin caps shall be exposed.
Surfacing: *Flintlastic SA Cap, Flintlastic GTA and Flintlastic GMS may be used with any approved roof
tile system mechanically fastened as specified in their current NOA.
•Flintlastic SA Cap, Flintlastic GTA and Flintlastic GMS may be used with any approved roof
tile system adhered as specified in their current NOA using any foam adhesive listed and
having a current tile adhesive NOA approval.
Must comply with appropriate Roofing Application Standard RAS 118, RAS 119, RAS 120 and
applicable Building Codes.
LABELING:
All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city,
state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County
Product Control Seal as shown below.
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 7 of 9
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
This Notice of Acceptance.
Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this material.
LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. CertainTeed underlayment roofing systems utilizing Flintlastic GTA, WinterGuard HT, WinterGuard Granular,
WinterGuard Sand, DiamondDeck, MetaLayment or Black Diamond Base Sheet as a cap membrane shall be
acceptable for use in asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications.
CertainTeed underlayment roofing systems utilizing RoofRunner or Roofers' Select shall be acceptable for use in
asphaltic shingles.
3. CertainTeed underlayment roofing systems utilizing Flintlastic SA Cap, Flintlastic GTA or Flintlastic GMS as a
cap membrane shall be acceptable for use in foam adhesive set and mechanically fastened roof tile systems as
specified in the surfacing option of the approved assemblies.
4. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. CertainTeed underlayment roofing systems shall be installed in strict compliance with
applicable Building Code.
5. CertainTeed underlayment roofing systems membranes shall be applied to a smooth, clean and dry surface with
deck free of irregularities.
6. CertainTeed underlayment roofing systems membranes shall not be applied over an existing roof membrane as a
recover system but may be applied over an approved roofing Base/Anchor sheet underlayment.
7. WinterGuard HT, WinterGuard Granular, WinterGuard Sand, Black Diamond Base Sheet, Flintlastic SA Cap,
MetaLayment, Diamond Deck, Flintlastic GMS, and Flintlastic GTA shall not be left exposed as a temporary roof
for longer than 180 days of application. RoofRunner and Roofers' Select shall not be left exposed as a temporary
roof for longer than 30 days after application.
8. CertainTeed underlayment products may be used with any approved roof covering Notice of Acceptance listing
CertainTeed underlayment products as a component part of an assembly in the Notice of Acceptance. If
CertainTeed underlayment products are not listed, a request may be made to the Authority Having Jurisdiction
(AHJ) or Miami -Dade County Product Control for approval provided that appropriate documentation is provided
to detail compatibility of the products, wind uplift resistance, and fire testing results.
9. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
10. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions.
11. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
12. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
NOA No.: 17-0306.07
M AMF�E�,cCauhErr Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 8 of 9
13. The maximum roof slope for use as roof tile underlayment for direct -to -deck tile assemblies shall be as follows:
(Limitations noted below are a result of the tile stacking/tile loading performance and do not reflect to that of the
underlayment. See Table Below)
Tile Profile
Flintlastic GMS'
Flintlastic SA Cape
Flintlastic GTA3
Flat Tile
4:12
6:12
6:12
Profiled Tile
4:12
5:12
6:12
'The following is applicable to all systems using and Flintlastic GMS:
*Slopes greater than 4:12 — Horizontal batten strips are required. Stage tiles touching horizontal battens; a
maximum of 10 tiles shall be stacked parallel to the slope (See Figure 2 below).
'The following is applicable to all systems using Flintlastic SA Cap:
*Slopes up to 5:12, Profiled Tile — Stage by placing two tiles perpendicular to the slope followed by maximum
four tiles on top parallel to the slope for a total of 6 tiles. (Illustrated in Figure 1 below).
*Slopes greater than those shown in the above table — Horizontal batten strips are required. Stage tiles touching
horizontal battens; a maximum of 10 tiles shall be stacked parallel to the slope (See Figure 2 below).
'The following is applicable to all systems using Flintlastic GTA:
*Tiles shall be stored on battens on roof pitches greater than 6:12".
Slope I
Front View Front
Figure 1: Staged Method, View
Figure 2: Batten Method
END OF THIS ACCEPTANCE
Side View
Figure 2: Batten Method
NOA No.: 17-0306.07
Expiration Date: 11/24/19
Approval Date: 07/26/18
Page 9 of 9