Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET1`t' LLLL 7 ;J l ST. LUCIF INORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form A, B, C Low Slope Application 1A3,4,6,6,7 'Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 1,2,4,5,6,7 Asphaltic Shingles A, B, D Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D 1,2,3,4,5,6.7' Wood Shingles and A, B, D 1,2,4,6,6,7 Shakes Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application Owners Notification for Roofing Considerations (Reroofing Only) 6. 7. Any Required Roof Testing/Calculation Documentation Form Roof1nfoFeb21 Rev Feb 18, 2021 ST. LUCIE WORKS Section A (General Information) Master Permit No. Process No. Contractors Name: Property Renovations & Construction, LLC License # CCC1329801 Job Address. 7910 James Road, Fort Pierce, FL 34951 ROOF CATEGORY 13 Low Slope ❑ Mechanically Fastened Tile 0 Mortar/Adhesive Set Tiles 0 Asphaltic Shingles 13 Metal Panel/Shingles 13Wood Shingles/Shakes 13 Prescriptive BUR-RAS 150 ROOF ROOF TYPE, 0 New roof 0 Repair 13 Maintenance ® Reroofing 13 Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) .__ _ 1700 Total (SF) 1700 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. if ST. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (if a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_" oc @ Lap, # Rows— ® " oc Zone 1 " oc @ Lap, # Rows woo Zone 2:—" oc @ Lap, # Rows ® moo Zone 3•--. -" oc @ Lap, # Rows— @ "oc Number of Fasteners Per Insulation Board: Zone 1'• Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterf lashing, Coping, Etc.. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. Parapet Height Mean Roof Height ST. LUCIE Section D (Steep Slope Roof System) Roof System Manufacturer: ian Notice of Acceptance Number: 20-0701.02 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: Zone 2e: Zone 2n:-Zone 2r: Zone 3e: Zone 3r: Deck Type: plywood \ Type Underiaymeni+ Tribuilt Underlayment & Tribuilt Sand SA Underla ment Roof Slope: a : 12 Insulation: / n a •• Ridge Ventilation? Yes Mean Roof Height TV Fire Barrier: � n/a Fastener Type & Spacing: Iring shank nails, 6" in side lap, 12" oc in fi Id Adhesive Type: n/a Type Cap Sheet n/a Roof Covering: Tamko Shingles Type & Size Drip Edge: 21/2" .032 Alumina ST LUCIE WORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1 'Moment Based Tile Calculations Per RAS 12T (Zone 1: x _ _� _ Mg: = Mn Product Approval Mi� (Zone 2e: x _ _) - Mg: = Mf1, Product Approval Mf (Zone 2n: x'L = - Mg: = Mr21, Product Approval Mf (Zone 2r: x 7L = - Mg: = M,�, Product Approval Mf (Zone 3e: x ;L _ -) -- Mg: = M,, Product Approval Mf (Zone 3r: x _ ) - Mg, = Mrar Product Approval Mf. Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf Mr required Moment Resistance* Mean Roof Height Roof Slope 15, 20' 25' 30' 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 `Must be used in conjunction with a list of moment based tile systems • For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L =x W:= ) -W: cos r =Fri Product Approval F' (Zone 2e: x L =x W:= ) -W: cos r =Fr2e Product Approval F' (Zone 2n: x L =x W:= ) -W: cos r =Fr2n Product Approval F' (Zone 2r: x L =x W:= ) -W: cos r =Fr2r Product Approval F' (Zone 3e: x L =x W:= ) -W: cos r =Fr3e Product Approval F' (Zone 3r: x L =x W:= ) -W: cos r =Fr3r Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Job Site Product Approval Roof Slope 9 Aerodynamic Multiplier a Restoring Moment due to Gravity Mg Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mg Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. UL Evaluation Report UL ER2919-01 Issued: May 21, 2013 Revised: July 05, 2019 Visit UL, LLC's Product iQTm database for the status of this Re UL Category Code: ULEZ CSI MasterFormat® DIVISION: 07 00 00 —THERMAL AND MOISTURE PROTECTION Sub -level 2: 07 30 00 — Steep Slope Roofing Sub -level 3: 07 31 00 — Shingles and Shakes Sub -level 4: 07 31 13 — Asphalt Shingles COMPANY: TAMKO BUILDING PRODUCTS LLC 220 WEST FOURTH STREET JOPLIN, MISSOURI 64801 (417) 624-6644 www.tamko.corn 1. SUBJECT: Asphalt Shingles ELITE GLASS -SEAL, F, P . AGE, HERITAGE IR, HERITAGE PREMIUM, HERITAGE WOODGATE, HERITAGE VINTAGE, HERITAGE VINTAGE 12 X 12 HIP AND RIDGE, 12?/, X 12 HIP AND RIDGE, AND 12'/. X 12 HERITAGE HIP AND RIDGE IR 2. SCOPE OF EVALUATION ■ 2018, 2015, 2012, and 2009 International Building Code O (IBC) ■ 2018, 2015, 2012, and 2009 International Residential Code ® (IRC) ■ ICC ES Acceptance Criteria for Quality Documentation (AC10), Dated January 2018