Loading...
HomeMy WebLinkAboutTruss"0 I N 'AO. —A" 21'-4" 4'-4" 14'-0" lild 39'—B" :3 Total Truss Quantity = 57 0 to PAAM F R CONNECTION. .I -r TYPICAL 7' SETBA CORNERSET LABEI AND SPACING 1� t4A�lel( k4d ,La4A — L1, jt-&o0 TIM IS A TRUSS PLAiCF70(r PLAN t15 DITQaEO TD AID IN THE DSTALLAT1a1 IF Tt UE= 840aE aFD TRUSS MAVDCS APO AROO DMIFIALS S{R� TM DR7RFNT. FSTE ES UN RAN DE rn tr �+ TRLLA. ESTL 01gRAID PARR AYIIDAR F14 LA DLSTALAOHI OE Tm1SSEi 1.65 DDAIJOS Y ARa tRs DE OI IA DE 11 A StRTJAa Labeled End Mark >nLVFl A7®NLYWIC Y TK f y Q=nt mrRTml Km a111J. C rA T�n�i aOL7�, IRa.s. Ala a taavD m lOf Olf al ALTOS Tnita wmtw c3cm tv Tm r 111Y oWSFi vLL m t AO'afO1 Vl1taD i1®t VARid APMN& my MwALL ALL FN" Vx,e N6f = AWWy WININ 1D t]tiCY a�'nL>m LOG O a�Qi6s'w Attr ILAa! Yi wStm fVl TIC AT f�IWOf161 mOQACI� wO✓Q'A, 1G �M 76 N8 uaT � m�AVMD � MO POTm�Mf)o1 Dc VmA IdTD1lZ T®a LAi rJBAi mitt PARIM 4WAS fNimlla. C AVM T mtic Ice N.11z lR Tta� m R m®ImOalm S CTA II A®rARJI GfdOS NIIQaalFi m Ki�AQ01 PItEVG iW F39df0 Htm t lAt P.Aml {mMmnn) w m m mmu rA]A 11lVAR lAt WGS Di{iifAS r41 lID liw>Z O TAC>Ll. T DT�1 AnIO N LA DCTALACM T A IC AND'AA OYLLILt cN4iA r6i lAS HMW 1'L IIAiLRldA Gr�IFADAi N6np VIEPAW cep W m C4wwwt IIIIIpAa16p LM EN tm ANIO o< YE lR iRDiSEE ¢ RIO till -al i')lar P�AA' A LViTAR F General Notes 1) 4idm h U. � � P W flat to be iofmrd gnn dde up. 2) N h " to be 9ttprm � wilm CUM 1� 3) Al tram tpodlq Is 24' O.C. wdml *OWN rood. 4) Pr Tnea Plata 6 tb BC9-al mtatnmddian pmnmat X-ha*q dtodd be placed at n imakun �q 15 Ot. aaam the rym, to ho npw at a x tra . of 20' baLnm each X-0Tam e- �aR M. ebutil n Avow Tdr to amt for arry ad6Oatd hocW ,1691, ROOF LOADING SCHEDULE TCDL 7O PSF BCLL = • PSF BCDL 10 PSF TOTAL = 37 PSF DURATION = 1.25 % WIND SPD/TYPE 160 ENCLOSED BLDG EXPOSURE — C USAGE — RESIDENTIAL CAT 11 WIND IMPORTANCE FACTOR= 1 UPLIFTS BASED ON= 9.2 PSF DESIGN CRITERIA FBC 2020 TPI 2014 Tmss member desiT & connector plate arcdni -d for ASCE 7-IE and mmmom forces from both components and claddings and main .d force tex ng systctru. ' These trusses have been revi nd to carry an additional 109 psfnar— urramt bottom chord live Iced. FLOOR LOADING SCHEDU TCLL PSF �CDL PSFCDL = PSFOTAL = PSF ROOF DESIGNED FOR SHINGLE AIL REACTIONS AND UPLIFTS ARE SHOWN ON ENGINEERING 01 WALL KEY ® 0 DESCRIPTION INR. DATE ttna oatttv,m Pant r�Dn1 tau torn 9AZ" ttn IMP twr anvu tan tour c tmtt 7-14 ttra t m, m talt vm twr T/N/l{ toa us tn• fa+rw Itef lP Ntf N/41 Rml to � w/IAm ma an NAutatwvwwa m 3MM rAt twrno ravt tamow ,.— t� LARD/ DE9CIMMON MIT. DATE tm = m vPAru m ttcv mt Aomwno .Aw rinnT tatty tlnAtta nrau.T xD 7rrie ttw lrA Jtlt wu� ENCARPENTER - CONTRACTORS OF AMERICA 3900 AVENUE G, N V. WINTER HAVEN FL13RIDA 33880 PHO)IEt(800) 959-8806 FAM (863) 294-2488 BUILDER D.R. HORTON STATEWIDE PROJECTCF23NME MODEL 1828/CAU/4EBB CCA PROJ/MODEL/ALT 7AB/ 320/182EC,E ALT DESC OTC 3423 TRNM CDR LOT 87 BLOCK .00 rPAGE r' I ENGINEERING PACKAGE 1 Builder: Project: Model/Building: Lot Alt: D R H 0 RTO N /STATEWIDE F77kA5/320 CREEKSIDE 182EC,E^^��„ � ...................................................................................... . _._ JobNumber: N334496 Revision Date: New Load #: �R101 1"a m 0 CARPENTER CONTRACTORS OF AMERICA, INC 0 3900 AVENUE G. N.W. WINTER HAVEN, FLORIDA 33880 PH (800) 959-8806 FAX (941) 294-7934 ti ALPINE March 13,20.19 ANrrWC&QAM Mir. Bob: Michaelis- C-#.r'.'6fit6r.'C- din'trActbr's. of. America, I nic.. ,390Q Avenue 0... Northwest' Wjht6t Haven, FL 33860 -6261 Re: AlternatiVd lhstdlidons.for 6 single ply carried truss with a width less than the -hanger width, and wood. .blotking,tp:p*q achieve full design d face -mounted: N. .0 ignioa 'VOW6.1orhgnge.r'attadhi-h6nt6'n,.-a-one ply .supporting girder. (R46f6tr66 detail WA37-02).. Dear Bob,.: :F& P single Ply carried truss 6. -width 16�t than the ha�igee. Width you can ihs;qW*.. prefabricated h p. jack scab .truss: (1-for wood filler blockjogi.- The chord: sites- 'chord..grqcles, and to be -the. seirrie as the single: pl.k.carried truss. The prefabricated jack scab truss. (*):Wil I ha.v6-a..minimum length of 481' and will.have a. minimum Dit6h-:of-,5A2, The single ply carri.e.d.tcuss shall have:.a reaction oil of 3, 500# or . less. Attach prefabricated. jack scafJaruss. with. two. (2rows: of 0.128"x3.0'?'GUn Nails at27 -O.C. PeeFigure I _bdlio)Please ..eef6tt6.th&Simpson gtrong: Tie Catalog 201:9;. page 6: Figure: for more information: Figure."I FoTa sipg1'e-p*["y'-g.ir"de'r*'th'at requires woo d'blocking to, a'chieve.10 design load Value for flaperMounte.d hangers -attach one wood- block to the back face of the single ply girder with thosarne size.. and dtade-.as'thd bott6m.C. -hotd,Ofthe. single -ply girder. The: VOdd:block length h to be. 'such that-the"w6cid blocking,- -extends to each adjacent "' U par 41 points ;(webs.and bottom chord intersections): Attach wood -of'0.128'�x& r blobk:('�).-witb-1WQ_-(2) rows Nails Gun. ails at. 0' 0. 0. per; row,. staggered UP applied to the 6760 Forum Drive Suite 305, bria'ndo; FL. 31.2821 - (OPP) 521-9100'-1(8(.3$) 422-8685. wwmalpineitm=m ALP' E AN MCOW" single ply -girder face; with an'additional (20) 0.128"x3.'o" Gun `Nails a#:each panel point. applied `to the, wood. 6lock.fare (See igure'2 WOW)..Please refer to th6.Simpson Strong -Tie Catalog C=C 20.19; page 216; Figure.1'for t ore information. WO . tom' �t � �ri:�Yr''�l ^C• � _• f ' ' .• zr -ram. ...-.. •�•- s�T'"' Fgure2l� .... .......... The' application of prefabricated jack scab truss foi' Wood filler:blocking or wood blocking to; achieve full. design load�value forface�mounted hangers. must be approved by the hardware manufacturer:• :All.edge-and end: distances, and spacingforall nail connections -must. be sufficient to'preventsplitting of 'wood.: If I can be. of any further assistance:or if you have any: questions, please -give -me a call. Sin :c ly,►,,,►,,,,,INnihy, . \+ �i .i ENS • `f No'...70861; :o: ; STATE f �r. William H.-Krickp.E'. ' Chief Engineer '°�,P''.0 :R:1D . Alp'in'e an 1TV11' Company /p Engineering Departm.erit. Orlando; FL. 6750 Forum Drive: Suite'305, °Oilaiido, FL .32821 - (80% 521-9.790 - (863) 422-8085 r �Nww.alphOtw:com ALPINE M"Cowftw April 26;:2019* Mr. Bob Michaelis Carpenter Coritradtort ofAthenicaI ne. Avenue �G-j N .-thweAt Winter Hav6n, FL 3388 . 0-6201� Dear. Bob,. .R6- Str6noback bridging. ' on eb6ftruss6t. .. I understand thete. is some. concern over our 'reddMtn6ndations f6rstr6tibback bridging on r'oof'tru' sses, '86-angliAck bridging for roof trusses is not.a requirement of-ANSI-7PI 2014 nor is: it a requirement of :the: -6 Component Safety Information E'�uf sfrongback Building Corn bridging 'on`roof trusses is cled. by_Q'o ­ hte�_Cofifekto _Contractors . s -.6f:.-Amerida:. -Str6hgb46k bridoltig,,seiry , es recommended: rp@� the follqwlr).g- two. functions: — One, bridging aligns the bottom -chords after they: pre- set Aso.. they -are urifform, along the''ceiling fine and " ;j'is-" ' '. '; ''i"' ­­M­­ " .. uniform . . . . .. in nd h p with­-COiling�sorvidetibi Twoi bridging reduces relative d6flecti61ni of. adjacent -trusses:, Strongbackbridging .doe's: tiot.;-or6Vent-prreduce -overall' individual d6fle6fiah, especially -ahy roof trusses, ...... . . ...... .. ......... .. .... _ ............ . .. . .... .. .. ....... ........ - pf s does not e . s :temporary or g6ftnafibrit: bracing and is not St pngOack- bridging in roof. trusses d 's ' o . serve .6 tem 6 ..ra g ihten,d6d to .distribute. I or design,- foods. -between cusses. Consequently, no desido load' have: d`,§tribuie .8 .been accounted for'With this detail and continuous §trdhgback.bddgiho shdUld'hotb6:Atta' ched between torbilrion and girder trusses. The use .:of bridging shall not. `interfere str9rigbac .erfere with other, design k b., dginq considerations as specified :by the Engin' . e0r'.Of R6cotd or the Building: Designer. -The outer ends .ofthe stronig)'Nack bridging s shad . I be attached. -to awall .*or anpthorsecure end. restraint; t- -or ap,specified,.by the Engineer of R66oWi6rAlid BUilding..Desjjh&r.. Strofi-back- bridging be f6. minimum OJ W borbiriai IUM On 6 h the d' . co: 9 lumber. ori t d t 0 epth. vertical:. . . i . Attach with *(8) f8d :common. nails (p. 1'62N3..5!) nails At:. each intersecting When -extending the - strdn back bridging overlap by -at. 'a.minimum of twofrusses. The-.Jocatioa of. fho.qtroogbackbridging` maybe specified by'the Truss ManUfacturieri,. Engineer ,df,R6dord,. or Building Designer: Please ieferto k-S! ""St'rong'b'ackihg'Provi�ions." or to Ajp1rie.:$Tk8R-jBR1014 deid for more. information. . shown (Figitre:1) is . Provisions" ' . .. . ....on. The'. graphic '; -: hu' ,6760 Forum DriveSuite 305, QrlMdo, FL 32821% - (800) 521-07K.- (863).422-8685 WWw-.WfJin6itvV,0m� Figure-1, -If Lalhbb of any further EissistariWor-ifyou "have :-.any questions; please; give me a call. William He Knck. Plz. phief.Engi.heeir Alpirte an [TW.:.Co.mpany Engineering D 6pa"ttmen"t -Od6ndq; - FL -576.0.'Forum Drive Suite:365, Grbfift FL 3282:1* (800). 521-9,790 - (8153).4224685 ww '' I- tw W.a pin.e.1 ...com /­b­ w4f ' _V 6W ;SCAB' STRUN63ACK. BRIDGING RECOMMENDATIONS 'SPLICE I WITH 10d:BDVGUN NAILS IW-.9 ROWS"Af MONGBACK BRIDGING' ATTAbHMtNt. ALTERNATIVES AN ffW4MMPAW 071313WOrtUdva VW10 200 matylaw Havhts, mo 63.0413. or lob � All scab -.on blocks sholl; be: -(x minimum, �2'xe4: 'stress g"Oeol mo-ALL str9ngback bridging .and bracing shiitt ,be :a. mInhUo 2X6 P- . Ine . purpose pose of strondb.ac--k briclo to- -develop load sharing between' Ind tr..1YSsesT resulting Ih an -ovdrpkLl .1hcroasg- In -the stl-Omess�.:of- the. floor. systemi 2x6* st?'Ongback bridging; pdkitlohdd• ids. ishbwn In Cletalls, 'is recommended at 10' =0` -D.C. (MOL)<;) sm-3160: terms: 'b ' 't ' -1.61bIrid' :and :Ilord'dmq­' are somei(mes mistakenly: used Ant' ' e "1natihg`� Is: -PLn , rchanqt imppr'.tom*1 structural r'p'q'pdrelment of dny• floor or raof system, R.efet- 'to.- the Truss. DesIgh 'Prp;*ing (TDD) :fors the; br4cInb r'k-.cjuIr.'bments Irid'h fb.i- L -6c Iv'IcIQAk .-truss component, 'Bridging;' particutaMy "strongbqtk.:';brIdgIng' i's .,Q:.. s r rec6mm.ehdatJdh- f bi.­tr�u$- system to. help control I'vi . bro. tior) In: addition: to alcilrig.. in the: dlstrby�tian of point' tbaols betWee__6 adjacent truss,k 'I .-strongbac bridging serves -to reduce Na qTS bounce. or reslaucLl vibratiom 'res-uttino: frommoving point oin't .10,4fti:50ch as footsteps: Tine Perfor'mancO. of. -all 'floor :systems -are.. enhanced by. the. installation of strbngIa.aitk- ' IorIdglnb and -t.hLiK6fOr.O:is­ strongly recommended by Alpine, For additional jnfdj^hatbh regarding<j7trongboqk bridging, refert.6 3CSJ'OuRcling 'Component Safety'lnformatlo'n5. A -Um' PSF REF T&M. ;PSF HATE. CM PS Nb. tE; , 6' 1. ... t. - . . .F . . IIRWG 11 &L PVF- 3TAI(E - F A ).,( 'PSF SHORING- Q.-ETAIL E.N. A-08 .. .. ..... ... :f Hf, P0, 4--X:44 1 2? Xl -ks: 71 q, H POST$- -'V. sq ia Is B-CAL11.9 NONE' -Pal Rat am 177 I UNV La 0 COM- e J.. . . . . . . . . . . . . ... ............ NO T -IF. AlA LETS -OF -CQNSI� TIM Al'54-1-AL A-11-13HING, �ORE HAW*�500# .14RE. "Tv B'E' &LA,op-om -�-4008 TIP - !k,. 5'011-Ma W. 4kfl% HA' r -c NTRATE '0 9ST-00 VC-STAL.- AT IL AST 2-TS U.58: S. 'D WrO.- FOP,'LUMBER PLATr-..S AND.' i.0 4EIR 0 T A 00 L t I w. ttk i I W a :NOT-R... IAL -0Q -A f: TO. W URPLIM- Oy FFI f11`DA.. Ric. blo& 66-'Of Cracked or Brok6n This drawing specifies repairs for a truss with broken chord i or web member, This design Is valld only for single ply trusses with 2x4 or 2x6 broken members. No more than one break per chord panel and no more than two breaks per truss ore allowed, Contact the truss manufacturer for any repairs that do not F comply with this detail, (B) = Damaged area, 12' max length of damaged section (L) = Minimum nailing distance on each side of damaged area (B) (S) = Two 2x4 or two 2x6 side members, same size, grade, and species as damaged member, Applyy one scab per face, Minimum side member lengths) = (2)(L) + (B) Scab member length (S) must be within the broken panel, Nall Into 2x4 Members using two (2) rows at 4' o.c., rows staggered, Nall Into 2x6 members using three (3) rows at 4' o.c„ rows stmggered, Nail using 10d box or gun nails (0.12810', min) Into ear-h side member; The maximum permitted lumber grade for -use with this detail Is limited to Visual grade 01 and MSR grade 1650f. This repair detail may be used for, broken connector plate at mid --panel splices, This repair detail may not be used for damaged chord or web sections occurring within the connector plate area. Broken chord may not support any tie-in loads. S. L L e �Typlcai ~ + o + o + o + o o + o + o + o + Stagger + = Back Face 10d Box (0.128' x 3', min) Nails, o = Front Face 2x4 Member - Double Row Staggerf 2x6 MMember - Triple Row Staggerer Nail SoadnQ Detail Member-! Repair Detail Load Duratlon = 0% Member forces may be Increased for Duration of Load Maximum Member Axial Force . Memberi Size L SPF-C HF DF-L SYP Web Only 2x4 12' 620# 635# 730# B004 Web Only ! 2x4 18' 975# 1055# 1295# 1415# Web or Chord 2x4 24 975# 1055# 1495# 1745# Web or Cord 2x6 1465# 1585# 2245# 2620# Web or Chord 2x4 30' 1910# 19600 2315# 2555# Web or Chord 2x6 2230# 2365# 3125# 3575# Web or Chord 2x4 .36' 2470# 2530# 2930# 3210# Web or Chord 2x6 3535#. 3635# 4295# 4745# Web or Chord 2x4 42 2975# 3045# 3505# 3835# Web or Chord 2x6 439544 4500# 52250 5725# Web or Chord 2x4 3460# 3540# 4070# 4445# Web or Chord 2x6 5165# 5280# 6095# 6660# LMJNnun 7 l Distance Hlnlnur L Distance 7f �� ONVARwNQce READ An fOLUN ALL WTET ON THIVDRAVi1101 REF MEMBER REPAIR mWORTANTss fUUSH THIS DRAVDIG TO ALL CDHIRACTDRS 14MUDING nE DISTAILERS. Trusses requlev extreme core In fabrieatinM hvAkv, sNpp1Installiro an and braeino. Refer to d DATE 10/O1/14 /ollor tM latest rdHlan o1 ]Csl atuud►�o Dorpavnt Safety ]n ornotlon,, By TP7 and SBCA) far sofrty pr•aeUers peke to perfrred+0 the t functions. Trotallers shall provlir tenpororyyhraeNp pr 7CSf. Unless rested etMn6rt, top ehor�aholl have prbperly attae7»d ttruetural sheatlNrfD bntl button ht o► vales erd DRWG REPCHRD1014 ahnll haw a proprrfy attncFkd rip_W cd4+o. Locations sheen for prrnonentA alo�tteral raetro �1SJP o eaW face Q I 102IL.I�1111=� Rrfsr io drarinps ffoA-Z Ier standard plat. poslblon., Alphe, n dNlaton of ITV lu6dlnC Crnpanenb Oro fnc, shall [et be rnpomlble Fore devlIatbn /eon AN ITW COMPANY tNs �roriny any faAurr to build the 4uss M eon�ornener rkh ANSI/TPI 1, ar for l+and�D, shIPDMo, l7stal10.tlon L •1yodnp of irucces , A sral•on tYls dro►InD x tovrr pope UetMp iF,ls drorl•.p, Lidmias aecrptonce of professke.ol �� any respr is __ solely for the des sheen. Ter sWtahllty aril use of CZ drerW 733BD Lakehiil Ddve for eny sirueturr le the rnpaark set oP ijo D gene al voter per AHSIIfPI l Seet, . EalhDky,Mo63045 For non Infarnntkn see thlr Jobs general notes ppsCCe aA9 t77ese reb sltesi SPACING 24,0' MAX ALPINPj rw.al ,9lts,eenf TPl. vw.tpintt,oroi SDCN rvr�sbeinductrya;t 1CO rrrJe rv.0rg gpd.E BOARD axi) i m .. ' V E'Y'F IN RAM Lumber Size and Grade Alnumum Requirements. • B aii,fiqaid— 4xi'6 2x*4L ICKINIX TRUS$- jiV#j2,`D02* 6eqcr TRUSS UNDER VALLEY -FRA' —=bF VACLEN' RAFTER.OR RIDGE MING cm 4tAlI50L9 p4fs 6h-ciAl-s P.ifW'6 bdh-e r 4W � 2j(wl i4w and CrR aab ytcO focations are Trimvk, vmrkffif.ln tdtolK&.Hd§a- Wd-voiha p r7 - 111 stager rPV,:3. 1, O.0O.C.91 4 . (YSFP) 12 Ediim cut-FAfkALLEL lb , VALLEY RAFTER BEAM, -EVERY TIORR RAFTERS -b: 7t[15:dr�Y�ing.appliesto'YallaysvYttt[:thafoltd.3Yld��condlt(ons: _Install. gfiV 14- -.M.ax[mum #fqAn'lp,'df height; 3,04-t .i& 149 mph,.Enabsed, Cat 11, A --XiT ftloted,-Exp Di IUN-1.0 -16, 1.80 mph; mp'h; VAL LET V PLA- t- Notes 14- en r th rd Ul Offilp' !-.TXPJ44L. -I{1NUNSA1'a i. briafter, are ;.are.not used,. 1 41$0 leli 6t us'ad, ant Not hted'ofhe��ui� traits' 7. &%l&!dffdjd. 4 1.6dto"ills '416d'we+nallt ieathirtQ 3. Cfjp`-0le.tcif.arfibi. 4. 5-3-6dtoe-WIfs 4 2 5d tae;jfzl fi S. -Sldapdi tki-taHi, 4*2:6dtd&ftlls 3 loo tdEkMUs,ea.ch sleepe r.;ky.u$s 6. ii dge:bqbtrA-:6-roof black 4 16't toe-TISUS •R99OAOFLPgcN .7. --fridje-lej , Sed f4tr.05- 4 l6d.W"Os S. .-Fruffld t% (TYR). 3c16.0-wa-na#s. .g. Trilsio,., kli3zkini 416d.toc-011f 10. Truwtd;olppte� 4144--tvVO)li Yr. am -t a d tlp`m P - 4S6d.toa hail's :ARE USED) .13. :Obv bearn tb. mftdt 4 l6dlole-nalls. NOTE;-.16a:1Q-16:& AS-41 d0MMb1Y NAILA WVNWO� Am. -wli FVLUW� At WMI CK .-Tt.- - U 46 54 PZEP NktkY -PA"MqG 2.1 r. kiracha. per. Tc ILLiti ZO 7 1 M DA101�'�A4 D R W..G V, CNV-180101-S -ow Xtr tt.'V,� �v '.P 4;;qi, -Aw� td%.� -tG nth fQ0., WD&� ww.,m 13 tTxyt 60 Ul 0 .0 0 0 .0 0. 0 NE M Tfwctiti Ami 10.,iu AKftn ap xw &IdT, -e- stlau. n Am F.C#mvobLm. er V� Al or "C' P W P4. . '. , .. L.D=-7 Q 50 1 61 kll " Ai"� Trw-.wat.Qk#* dvokv im 441-wm Mvlr�' ?�ylw *U*Alty Of NALITK f- fcr , - - 1 ­ 4 H.':�b' z 64M ::SRxLi c• q ABovs b, I Face -Mount Hangers - 1-Joists, Glulam and SCL 1�( These products are available with additional corrosion protection. For more information, see p.15. Codes: See p.12 for Code Reference Key Chart. rel U v . Carried 'Dimensions " Fasteners'' Allowable Loads Member (in) Actual Joist Model ; Min l DF/SP �� SPF/HF Code Size No E `y Weh M Species Header ". #Species Header" ' Ref. (in.) s Sbff W H B Face , "JoisT Uplift Floor :Snow Roofi ;Floor Snow R66f. Regd 0) 4{i.15}{12;*),.(i00)=(115)' (125) IUS2.56/16 - 2$/a 16 2 Min. (14) 0.148 x 3 - 7O 1,660 1,805 1,805 1,425 1,555 1,555 Max. (16) 0,148 x 3 - 70 1,805 1,805 11,805 1,555 1,555 1,555 21/2 x 16 MIU2.56/16 - 2% 106 21/z - (24) 0.162 x 31/z (2) 0.148 x 11h 230 3,455 3,920 14,045, 2,970 3,370 3,480 U314 ✓ 29/16 101h 2 - (16) 0.162 x 31/z" (6) 0.148 x 11h" 970 1,945 2,205 2,375 1,675 1,895 2,045 HU316 / HUC316 ✓ 29/I6 141A 21h - (20) 0.162 x 31/z (8) 0.148 x 11/z 1,515 2,975 3,360I 3,610 2,565 2,895 3,110 IBC, -MIU2:56/18 -, 2OA6 171s =_ _ 21h - 26 "0.162 x 31h ( ) (2} O�T48 x 1`.230 , 3,745 4,045 4 045j 3;220" 3,480 3,480,, FL, LA 21h x 18 HU3161 HUG316 `• ✓ 2?h6 141Y .2'h. - (20) 0.162 x 31h"_ , (8) O.i#8 x 11h . �: 1515" 2,975 3,360 3 610- 2 565 2 895 3,110 21h x 20 MIU2.56/20 • - 29/16 19316 21h - (28) 0.162 x 31h (2) 0.148 x 11/2 230 4,030 4,060 4,060 3,465 3,495 3,495 21h x 22 to 26 MIU2:56/20 �, _ • : ✓ .2sti6 197/16 21/z - (28) 0162 x 31Iz (2} 0.148 x 11/z 230 4-030, 4,060 4,060 3;465 3 495 3,495'. 29/6 x 91/4 to 26 29AG" wide joists use the same hangers as 21/2" wide joists and have the same loads. 3 h - M63.12/9 L - 3 "" 91M 2'✓z -- _ _(16)"0.1fi2 k 311z (2} tf 148 x 11Iz' 230 2305 2 615" € 2 820 1980' 2,245` 2,4 25 x�9 ' HU210 2 ! HUC210 2' • ✓ 3= $73/1c 21h Max. ' (18)"0.162x37/(10}i0148 x 3.; .a.:5 2;680, 3,020` 3,25012;305:;2;fi05 2,800` IBC, MIU3.12/11 - 31/a 111/6 . 21/z - (20) 0.162 x 31h (2) 0.148 x 11h 230 2,880 3,135 3,135 12,475 2,695 2,695 FL, 3 x 117/a -" ' " tiU2122 PHUC212=2 ✓ 3%- --109Az " --21✓2 idlaf�: " (22) 0.162 x 31/z (10) 0.148 X 1;795 3;275' 3;69� 3,9'T0 2;820 '3,180 3,425 LA HI1;195%i 7HHlr1, 1 ., 111/ I `113/--' 91h - 194%n1R9s:4h-- : 7191"nURv3 HU3 25/161, ` HUC3 25/16 ' 3 ✓4 = 131J6 21h. Min: �(26) 0.162-x 31/z (8) 0148 x 3 ." 1515` 2,975 3,360. 3;610 t 2 560 2 890 3,105 . Max. (26) p 162 x 31/z- , (12)`04 x 3 `, r;.,5 3 870 4,365 4;095 3;330],3 755, 4,040 - HUCg,, 31/ - (12)1/4".x21/z"SDS _, l 554, �I3%glulam, , F3L HGUS3,2�u/10 = 3'✓4 ( ;-S6la"i r " 4 " (46) OA2 x 31/ , (J6)x31/z, 4;095 9,100 9,100 i 910D1 7825;,7,825] 7.825', IBC, HGUS3c25/12 3'14 l 405/a 4"', -,. (56)"0:162 x 3"4` (20) 0.162 x 31Iz 4 40 '9,400; 9,400 9,400 8 0$5 8;085, 8,085', FL LGU3425" SDS t0, 4?h,-.1/4"421✓z", SDS(12a'x 21/i" '5,555, 62 ri a�,13,- 40 5 f 5,265'' HHUS46 - 35/6 51/s 3 - (14) 0.162 x 31/z (6) 0.162 x 31/2 1,320 2,785 3,155 3,405 2,395 2,715 2,930 31h x 51/4 HGUS46 • • - 3% 47/1i6 4 - (20) 0.162 x 31/z (8) 0.162 x 31/z 2,155 4,360 4,885 5,230 j 3,750 4,200 4,500 HUS48 w •' •'' • - 189A61 .614s 2 : - (6) 0.162 x Alh (6) 0.162 x31/z .: 1,326"1,595 1,815 1960 1 365,11,555 i 1,680'. 31hx71/4-.HHUS48=' •' • - Ni 71✓e, ,3 `.- (22)0.162x31/2 (8}'fl162•X"3Yz ,7801 4,210 4,77015140 3615 4,095 4,415 HGUS48 '", ,• •" = 7'f6. ' "4" .+,- (36) 0.162 x 31/ {12} 0.162x 3?h �; 3;235` 7K460 7,46& 7,460 6,415 6,4315 6,415'' IUS3.56/9.5 - 3%1 91h 2 - (10) 0.148 x 3 - 70 1,185 1,345 1,455 1,020 1,160 1,250 MIU3.56/9 - 39/16 8'-Mfi 21h - (16) 0.162 x 31h (2) 0.148 x 11/z 210 2,305 2,615 2,820 1,980 2,245 2,425 U410 ✓ 31/16 83/s 2 - (14) 0.162 x 31/z (6) 0.148 x 3 970 2,015 2,285 2,465 1,735 1,965 2,120 HUS410 - 39ti6 815/16 2 - (8) 0.162 x 31h (8) 0.162 x 31/z 2,990 2,125 2,420 2,615 1,820 2,070 2,240 HHUS410 - 3% 9 3 - (30) 0.162 x 31/z (10) 0.162 x 31/z 3,565 5,635 6,380 6,445 4,845 5,486 5,545 31/z x 91/z HU410/HUC410 ✓ 39/16 8% 21/z - (36) 0.162 x 31h 1 (12) 0.162 x 31/z 3,235 7,460 7,460 7,460 6,415 6,415 16,415 H000410-SDS - 39A6 9 3 - (12)114" x 21/z" SDS (6)114" x 21/2' SDS 2,265 4,500 4,50G 4,500 3,240 3,240 13,240 HGUS410 - 3% 91✓G 4 - (46) 0.162 x 31/z (16) 0162 x 31/z 4,095 9,100 9,100 19,100 7,825 7,825 7,825 IBC, LGU3.63-SDS - 3% 8 to 30 41/z - (16)1/4" x 21h" SDS (12)1/4" x 21/z" SDS 5,555 6,720 6,720 6,720 4,840 4,840 4,840 LA MGU3.63-SDS - 35/s 91/4 to 30 41/z - (24)1/4" x 21h" SDS (16)1/4" x 21/z" SDS 7,260 9,450 9,450 19,450 6,805 6,805 6,805 IUS3.56/17.88 - 3 - 1171a� ,. 2, - _-, (12)'OJ48 x 3 a 70" " 1,420 1;615 1745,1"1 220 f 1;390! 1,485; MIU3.56111„ , - l3' 6 ,171/a 21h �- �(26):0.162 Oi' - (2)-0.148'X11/z �_ 210 2,880' "3,135 j 3,135 247512;69512,695t ✓ 1,30A61- - 110 1- 2 -, 31/z x 117/6 ':HU412 /.HUC412 b • •" - " 3 46 j 105fi 21h fjjax `.(22);0:1 HUCD412�,SDS •. -- 3 6 11:_, - "(14)M4"x HGUS412, " - i 3 A 1 ' .10?ti6 4 - (56),01 LGU3:63-SDS , •' -: i 341 8 to "30 41/z '`- (16)" A" z �MGU3.63=SDS" - �31%, 9?/ato30 "41h�,--. (24),/, HGU3.63=`SDS - f '35/6 ; it lt`o"30 4?/z ,-" (36)1/4" x 46 See footnotes on p.150. r THA/THAC Adjustable, Truss Hangers This product is preferable to similar connectors because of (a) easier installation, (b) higher loads, (c) lower.installed cost, or a combination of these features. The THA series have extra long straps that can be field -formed to give height adjustability and top -flange hanger convenience. THA hangers can be installed as top -flange or face -mount hangers. THA4x and THA2x-2 models feature a dense nail pattern in the straps, which provides more installation options and allows for easy top -flange installation. Material: See table Finish: Galvanized. Some products available in ZMAX® coating. See Corrosion Information, pp.13-15. Installation: • Use all specified fasteners; see General Notes. The following installation methods may be used: • Top -Flange Installation — The straps must be field formed over the header.— see table for minimum top -flange requirements. Install top and face nails according to the table. Top nails shall not be within'/4" from the edge of the top -flange members. For the THA29 •nailer used4orejoist attachment,must be driverratan --_ angle so that they penetrate through the corner of the joist and into the header. For all other top -flange installations, straighten the double -shear nailing tabs and install the nails straight into the. joist. • Face -Mount (Min.) Installation —.Install face nails according to the table, with at least half of the required fasteners in the top half of the header. Not all,nail. holes in the straps will be filled. . Nails must have a minimum 1/2" edge distance. Straighten the double -shear nailing tabs and install the joist nails straight into the joist. The face -mount (min.) installation option accommodates conditions where the.supported'member hangs either partially or entirely below the header. • Face -Mount (Max.) installation — Install face nails according to the table. Not all nail holes in the straps will be filled except for the following.models: THA29, THA213, THA218 and THA413. For all other models with more nail holes than required, the straps may be installed straight or wrapped over the header, with the tabulated quantity of face nails installed into the face and top of the header. The lowest four face holes must be filled. Nails used for the joist attachment must be driven at an angle so that they penetrate through the corner of the joist into the header. • Uplift — Lowest face nails must be filled to achieve uplift loads. Options: • THA hangers available with the header flanges turned in for 35/s" (except THA413) and larger, with no load reduction — order THAC hanger. Codes: See p.12 for Code Reference Key Chart Double - Shear Nailing Top View Double-Shear Nailing Side View; Do not bend tab 13/4' for THAC422 for 422-2 426-2 THAC422 1Y4 typical 21/2'for THA422-2 and THA426-2 THA418 Double 4x2— 2face nails Use full table value (total) Single 4x2—� a,. 4 top nails Face nails Top nails See (total) nailer table pertable per table ' Straighten the double shear nailing tabs and install nails straight into the joist Typical THA Top Flange Installation on a Nailer (except THA29) THA422 Face -Mount (Max.) Installation Straps may be installed straight or wrapped over with tabulated face nails installed into top and face of heade Dome Double -Shear Nailing Side View (Available on some models) Straighten the double shear nailing tabs and install nails straight Typical THA422 Top Flange Installation on a 4x2 Floor Truss THA44 Face -Mount (Min.) Installation ryplucu r rl ycv Top Flange Installation er to tnote 5 p.187 86 THA/THAC ........................................................... _......... _............................. _..... _...................................................... _... _........ :................. _........................... _............................ ....................................... ............ _ .......... Adjustable Truss Hangers (cont.) These products are available with additional corrosion •protection. For more information, see p.15. a 11/z - 1 (2) 0.148 x 3 (6) 0.148 x 3 1 (4) 0.148 x 3 525 11,750 1,750 1 1,7 50 450 1.1,330 11,330 1,330 THA29 18 1-1/8 911Jis 51/e 2M6 - (4) 0.148 x 3 (6) 0.148 x 3 (4) 0.148 x 3 525 2,610 2,610 2,610 450 1,985 1,985 1,985 THA213 )8 1 sla 135fis 51jzl48 x i„ ��.. • THA218 18 1 % 173/is 51/z 2 (4) 0148 x 3 (2)0.148x3 (4) 0.148 x 11/z 1,460 1 "60 1,460 1; 10 1110 1 10' THA218 2 16 -31Ia=" 17111446 .8 „, `2 " (4} 0162x 3�h ',(2} 0162 x'31h 6}'Q';1481t 3F1.9611) a 3 , rts9 "' 191d . = I;49�i 1 ui a 1 515" " FL, _:. LA THA222-2 16 31/a 22% 8 2 - (4) 0.162 x 3% (2) 0.162 x 3% (6)0.148x3 1 1;9'.'5 1,995 - 1:490 1,515 1 11515 THA418 116 1 3s/e 171/z 71/s 1 2 1- (4) 0.162 x 31/z (2) 0.162 x 31/z (6) 0.148 x 3 1 11,960 1 1,995 1 1 Q95 1- 1:490 11,5151 1,515 �THA422 : 16 35Ia e 7f 2 r�1) 062 xA31 (2),062 X3i (.C414871 i 1 995' T t9ti f t t11=L; e, .. THA426 1 14 1 3% 1 26 77/a 1 2 1-. (4) 0.162 x 31/z (4) 0.162.x 3% (6) 0.162 x 31/z - 2,435 1 2,435 1 2,435 1 12,095 12,095 1 2,095 THA426-2 114 1 71/4 1261tis1 93/4 I 2 .1 - 1(4) 0.162.x 31/z1 (4) 0.162 x 31/z 1(6) 0.162 x 31/z1 - 13,33013,3301 3,330 1 - 12,86512,8651 2,865 THA29 118 115/a 1971/e 151/a I - 1911tis I - I (16) 0.148 x 3 I (4) 0.148 x 3 1525 12,26512,265 I 2,265 1450 11950 11950 I 1950 THA218 118 1 15/a 1173As l 51/z 1 - 1173A6 I - 1 (18) 0.148 x 3 1 (4) 0.148 x 3 1 855 12,450 12,450 1 2,450 1 735 12105 12105 1 2105 THA222-2 16 1 31A 22YIs 8 1 - 141/s 1 - THA413 $ 35Ia3is 411z, „ 1.1331a THA418 16 3% 171/z 77/a - 141/s - THA422�'6 3% 22 `77/s41/1s THA426 14 35/a 26 77/a - 161A6 - FL I 0162 X 31h (6) 0.162 x 3yh $` f1, 3 i c o 595; 2,P45 2 84 },8� : IBC, FL, 0.162 x 31/z (6) 0.162 x 31/z 1,855 3,310 3,310 3,314 1,595 2:845 2,845 2,845 LA 0.162 x 31/z1(6) 0.162 x 31/z1 1,85513:31013,3"101 3,310 1 1595 12,845,12,8451 2,845 0.162 x 31/z1(6) 0.162 x 31/z1 1,855 1 4,415 1 4,480 1 4,480 1 1,595 1 3,795 1 3,855 1 3,855 FL. I THA426-2 14 1 71/a 261tis 93/4 - 18. - 0.162 x 31/zI(6) 0.162 x 31/zl 1,855 15,520 15,520 I 5,520 11,595 14,745 14,745 I 4,745 1. Uplift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 2. Wind (160) is a download rating. 3. Min. top flange refers to the minimum length of strap that must be field -formed over the header. The tabulated bads for the THA29 with 11h" min. top flange are based on a single 2x carrying member; all other top -flange installation loads are based on a minimum 2-ply 2x carrying member. For 4x2 truss carrying members with double top chords, use the specified fasteners for full tabulated values. For single 4x2 top chord or nailer applications, refer to the Nailer Table. 4. Face -mount installation bads are based on a two-ply 2x carrying member minimum. For single 2x carrying members, use 0.148" x 11h" nails in the carrying member and tabulated fasteners in the carried member, and use 0.80 of the table value for 18 gauge, and 0.68 of the table value for 16 gauge and 14 gauge. 5. For the THA 2x models, one strap may be installed vertically according to the face -mount nailing requirements and the other strap wrapped over the truss chord according to the top -flange nailing requirements (see drawing on p. 186) and achieve full tabulated top -flange installation loads. 6. Refer to installation instructions regarding fastener installation into carried Ooist) member. Based on the installation condition, nails will be installed either straight with straighted double -shear nailing tabs or slanted. 7. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. SIMPSON LUS/MUS/HUS/HHUS/HGUS Face -Mount Joist Hangers 2v��EERFG This product is preferable to similar connectors because k+ of a) easier installation, b) higher loads, c) lower installed cost, or a combination of these features. J) b The double -shear hanger series, ranging from the fight -capacity LUS hangers to the highest -capacity HGUS hangers, feature innovative Bauble -shear .ailing that distributes the load through two points on each joist nail for greater strength. This allows for fewer nails, faster installation and the use of all common nails for the same connection. .For medium -load truss applications, the MUS offers a lower -cost alternative and easier installation than the HUS or THA hangers, while providing greater load capacity and bearing than the LUS. 'Material: See tables on pp. 194-195 Finish: Galvanized. Some products available in stainless steel 'or ZMAX® coating. See Corrosion Information, pp.13-15. Installation: • Use all specified fasteners; see General Notes. • Nails must be driven at an angle through the joist or truss into the header to achieve the table loads. Nbt designed for weld6d o'r"naTer applications. Options: • LUS and MUS hangers cannot be modified • Concealed flanges are not available for HGUS and HHUS • Other sizes available; consult your Simpson Strong -Tie representative Codes: See p.12 for Code Reference Key Chart Double -Shear Nairing Top View Double -Shear Nairing Side View Do not bend tab Dome Double -Shear Nailing Side View (Available on CVV some models) 1. for 2)es 1',Ae for Vs fl. �II 10' LUS28 HHUS210-2 PW MUS28 Q 6 OP L nj:. II;n n t. V A� 2^� H US210 (HUS26, HUS28, and HHUS similar) Or HGUS28-2 Typical HUS26 Installation with Reduced Heel Height (multiple member fastening by Designer) 19 LUS/MUS/HUS/HHUS/HGUS Face -Mount Joist Hangers (cont.) Model No° Mir. a Heel H Height Ga. Dimensionslin.) Fasteners- ; W : H �,g Carrying Carved Member Single 2x Sizes LUS24 ° 25/a, , : 18 .' 111/i6 3'le .i 4a/a , _ 1/a 1 1a ' `{4),0 748 x�3"' : (4) 0148 x 3 E (2) 0.148 x 3 (4) 0.481C3 LUSH 4"Ja`.: MUS26 4% 18 'l IA6 5 A6 2 (6) 0.148 x 3 1 (6) 0.148 x 3 HUS26 4-A6 16 1 % 5% 3 (14) 0.162 x 31/z (6) 0.162 x 31/2 `HGUS26 4sl'a-' 12 . i s/a 5ale.,,,(,�'5 ° '(20) 0,162 x3Y l {8) 0.162,X 314 LUS28, ,,. 4%11'1616 - :65(ea , .1?✓a ; (6}.p148"x,3,'"'' ., ,(4) 0.148,X3 ; MUS28 65ti6 18 151, 613A6 2 (8) 0.148 x 3 (8) 0.148 x 3 HUS28 61/2 16 15/a 7 3 (22) 0.162 x 31/2 (8) 0.162 x 31h HGUS28 69A6 12 15/a 71/s 5 (36) 0.162 x 31/2 (12) 0.162 x 31/2 LUS210 41/a -= _ 18' 19A, ' 71� ,s ,13/a {$) 0148 X,3, ,'r' {4) 0.14$ x 3„ 'HUS210 �8a/s 0.162 x 31/2,-[,(10) 6.162 x.31W'; HGUS21p ,8af6., 12" 14 y 9M8 ' '5', (46);0.162X3'lz-- �,(16)0.162x 1 x V1. See table below for allowable bads. N 1= .a N IL Q Q =1 These products are available with additional corrosion protection. For more information, see p.15. For stainless -steel fasteners, see p.21. Many of these products are approved for installation 1 with Strong -Drives SD Connector screws. See pp. 335-337 for more information. DF-Allowable Loads,,,' - SP Allows ble Loads SRFIHF Allovuable Loads Cade: Model h1o, Upliftl `Floor . Snow ° Roof: Wind ; Uphft1"" Floor 'Snow " ,�ioof Wmd Up11fti Floor Snow Roof Wind` Ref.,_,; (160) (100) {115) (125) {1B0) (160)"; , (100) (115) 1125) (�60) 160) ? (100) (160)'; Single 2x Sizes W824f 48, ,676 ` °' 765 : . SM '1,0,45 ,435 ° .725 890'. -1123 ,:. 495°,` -< 565' 805 " : 770 , LUS26 1,165 865 990 1,070 1,355 1,165 ' 935 1,070 1,150 1,475 865 635 725 785 1,000 IBC, FL, MUS26'405 .,'156�-- 1' >3,` 1,a60°S)0; a:W 955,.. 1090 1;180 LA HUS26 1,320 2,735 3,095 3,235 3,235 1,320 2,960 3:280 3,280 3,280 1,150 2,350 22660 2:780 2,780 HGUS26 ,c�r`;4 "4,340: 4,850 5,170 . 5,390, to 67a ?4;690 ; 5;220, •,5,390 -5,390 £3fl ,� ;610 ., , 3,870 3,985 , IBC, FL LUS28 1 1,165 1,100 1 1,260 1,350 1 1725 1 1165 1195 1,360 1465 1 1,730 865 810 925 1 1,000 1270 ,MUS28" ,(,320 , T1,730' = 1,975`' 2;'12,5 225 .' 1 ku,, "1,875 2,135 '2255' -2;c55 .1;f50 '-1,270 ', 1;455 1,575 1,9"rs.s IBC, FL, LA HUS28 1,760 4,095 4,095 4,095 4,095 1,760 4,095 4,095 4,095 4,005 1,480 3,520 3,520 3,520 3,520 HGUS28 1,650 7;2751' 7,275 7275-, 7,275 '' 1,650, 7,275. ", 727w` . 7,275, '. 7,275< ` 1,320 , ,3.67b ;3,820 -:3;915 "41250 IBC, FL LUS210 1,165 1,335 1,530 1,640 2,090 1,165 1,450 1,655 1,775 2,270 865 985 1,120 1,215 1,50 1 113C, FL, HU8210 2r63 5;450 " 5,95,= 5,830 5,830 '; 2,6381 ` s5 • - s,7 SO . . 5,83J . :5 a�0 2:22 `2;33' 2,4L5 2;53' . 2; 325'', LA H US210 2,090 9,100 9,100 9,100 9,100 2,090 9'00 9,100 (3,100 9.100 1:545 6,341 6,730 6,730 1 6,730 1 1BC, FL 1. For dimensions and fastener information, see table above. See table footnotes on p. 195. HHUS/HGUS See Hanger Options information on pp. 98-99. HHUS - Sloped and/or Skewed Seat • HHUS hangers can be skewed to a maximum of 45' and/or sloped to a maximum of 45' • For skew only, maximum allowable download is 0.85 of the table load • For sloped only or sloped and skewed hangers, the maximum allowable download is 0.65 of the table load • Uplift loads for sloped/skewed conditions are 0.72 of the table load, not to exceed 2,475 lb. • The joist must be bevel -cut to allow for double shear nailing HGUS - Skewed Seat • HGUS hangers can be skewed only to a maximum of 451. Allowable loads are: HGUS Seat Width Joist Down Load Uplift W < 2" Square cut 0.62 of table load 0.46 of table load W < 2" Bevel cut 0.72 of table load 0.46 of table load 2" < W < 6" Bevel cut 0.85 of table load 0.41 of table load 2" < W < 6" Square cut 0.46 of table load 0.41 of table load W > 6" Bevel cut 0.85 of table load 0.41 of table load Acute ' side bpeciry angle Top View HHUS Hanger Skewed Right hoist must be bevel cut) All joist nails installed on the outside angle'(non-acute side). 94 LUS/M US/H US/H H US/HG US These products are available with For stainless Many of these products are approved for installation 19 additional corrosion protection. steel fasteners, @ with Strong -Drive' SD Connector screws. For more information, see p. 15. see p. 21. See pp. 335-337 for more information. S, Fs-! 77 Double 2x Sizes LPS24 2 ' "' 2% 31/b: 1�'31� "2,, :1 ) 016 2 X 31 Oi��, 31/k 4,0162X 2x 1/2 1030, 1,170,695` 61 _8 HHUS26-2 45A6 14 3-A6 53/a 3 (14) 0.162 x 31/2 (6) 0.162 x 31h 1,320 2,830 3,190 3,415 14,250 1,135 2,435 1 2,745 2,935 3,655 HGUS26-2 49A6 12 35A6 57AG 4 (20) 0.162 x 31/2 (8) 0.162 x 31/2 2,155 4,340 4,850 5,170 5,575 1,855 3,730 4,170 4,445 4,795 3' 2, )�01 62 x 3 J4 1/2 61 1 40 �030 �916, 301+" 86i q'148 IBC, FL, HHU8�8-2,:,'­," 9A "6 6 14,' '714- 3 -(22)�O.� �x 162 �1/21 6 Z'x 31/2 ,7§01 ',265, 4', A 810 1,515'13,6 0 _,1 'A 'A '3 5 .435 1 5il LA HGUS284-"`A' 69A6n '; 12 3-546- 73; 4, A 62 i 3,1�i, 62 31�, x �,�5 7( 0 3,466, `2,780' 6 415, ,6 05 6;41 6,415: LUS210-2 67As 18 31/a 9 2 (8) 0.162 x 31/2 (6) 0.162 x 31/2 1,445 1,830 2,075 2,245 2,830 1;245 1,575 1,785 1,930 2,435 HHUS210-2 83/a 14 3% 8 7/a 3 (30) 0.162 x 31/2 (10) 0.162 x 31/2 3r5501 5,705 6,435 1 6,485I 6;485 13,335 4,605 5,340 5,060 5,190 HGUS210-2 89A6 12 3-As ff% 4 (46) 0.162 x 31h (16) 0.162 x 31h 4,095 1 9,100 9,100 19,100 9,100 13,520 7,460 7,825 7,825 7,825 Triple 2x Sizes HGUM-3 11, 41% .1162`x8lW 4_ 85 �,730 4 79 4;4�4,�' '4',795� IBC, F L , '12": OAA 711a ;,(30�0,16�x3i/2 ' '31A 3;238 460 7,460' 278Q, 6:418 05" �6 LA HHUS210-3 .8% 14 417A6. 87/8. 3 (30) 0.162 x 31/2 (10) 0.162 x 31/2 3,405 5,630 6,375 6,485 6,485 2,930 4,840 5,485 5,575 5,575 FL HGUS210-3 b13A6 12 91/4 4 (46) 0.162 x 31/2 (16) 0.162 x 31/2 4,095 9,100 9,100 9,100 9,100 3,520 5 7,82L 7,825 7,825 7,825 HGUS2124 62i" 'h 1 3, �b ql� PQ4 A04 J -, 7,78 IBG, FL, LA Quadruple 2x Sizes oy2_-F'Az 4, J VUXu' 6 V'IL- '4' ('HO' I IBG, FL, 71/4 1 12 6-,16 7-As 4 (36) 0.162 x 31/2 (12) 0.162 x 31/2 13,235 1 7,460 I 7,460 7,460 7,460 2,780 1 6,415 1 6,415 16,415 6,415 1 LA I I I �Lj 83/.T14 61/. 87A 3 (30) 0.162 x 31/2 1 (10)0.162: 31/213,40515,63016,37516,48516,48512,93014,84015,48515,57515,5751 FL I 4x Sizes IBC, FL, LA IBC, FL LUS48 43/a 18 39A6 63/4 2 (6) 0.162 x 31/2 (4) 0.162 x 31h 1,060 1,315 1,490 1,610 2,0301 910 1,130 1 1,280 11,385 1,745 IBC, FL, HUS48 61/8 14 39A6 7 2 (6) 0.162 x 31/2 (6) 0.162 x 31h 1,320 1,580 1,790 1,930 2,415 1:135 1,360 1,540 1,660 2,075 LA HHUS48 61/2 14 3% 71/8 3 (22) 0.162 x 31/2 (8) 0.162 x 31/2 1,760 4,265 4,810 5,155 5,980 1,515 3,670 4,135 4,435 5,145 HGUS48 06 12 3% 71A6 4 (36) 0.162 x 31/2 (12) 0.162 x 31/2 3,235 7,460 7,460 7,460 7,460 2,780 6,415 6,415 6,415 6,415 WS410, ;',ql/4 1 18 8�/4 2°_' (8) 0.162,x 31/2 6 2, k 3,1/2 1,44S' "G__;,4 83 1, 2 5 1;5?6 !,��5 io, 435 _AHUS410I 8 Na 4 14 35% '3 '(3q)�P.162 x 31/2 fl 0�-A­162 x 31/2 3,t,�P 5j705 6i43 '4�9 05 5,535 5: 577 5,5 75 0 , ? J11 X T�9JPl) ',9100'.,'3,520 __ ' - q?§_ 7825 - _�n IBLA HGUS412 10346 12 35/a 10% 4 (56)0.162x3l/2 (20)0.162x3l/2 5,695 9:045 9,045, U405 9:0-�5 4.9010 7,780 -7,780 7,780 7,780 HGUS414 11 7H. 12 35/a_ 12316 4 (66) 0.162 x 31h (22) 0.162 x 31h 5,695,10,125 10,125 10,125 10,125 4,900 8,190 8,190 , 8,190 . 8,190 Double U Sizes FL 1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern. 2. Wind (160) is a download rating. 3. Minimum heel height shown is required to achieve full table loads. For less than minimum heel height, see technical bulletin T-C-REDHEEL at strongtie.com. 4. Truss chord cross -grain tension may limit allowable loads in accordance with ANSVrPl 1-2014. Simpson Strong -Tie® Connector Selector® software includes the evaluation of cross -grain tension in its hanger allowable loads. For additional information, contact Simpson Strong Tie. 5. Loads shown are based on a two-ply 2x carrying member minimum for nailed hangers. With 3x carrying members, use 0.162" x 21h' nails in the header and 0.162" x 31h" in the joist, with no load reduction. With single 2x carrying members, use 0.148" x 1112" nails in the header and 0.148' x 3" in the joist, and reduce the load to 0.64 of the table value. 6. Fasteners: Nail dimensions in the table are risted diameter by length. See pp. 21-22 for fastener information. HTU Face -Mount Truss Hanger The HTU face -mount truss hanger has nail patterns designed specifically for shallow heel heights, so that full allowable loads (with minimum nailing) apply to heel heights as low as 37/a". Minimum and maximum nailing options provide solutions for varying heel heights and end conditions. Alternate allowable loads are provided for gaps between the end of the truss.and the carrying member up to'/2" max. to allow for greater construction tolerances (maximum gap for standard allowable loads is 'Is" per ASTM D1761 and D7147). See technical bulletin T-C-HANGERGAP at strongtie.com for more information. Material: 16 gauge w Finish: Galvanized L 0 Installation: O c • Use all specified fasteners; see General Notes • Can -be installed filling round holes only, or filling V round and triangle holes for maximum values N See alternate installation for applications using the HTU26 on a2x4 carrying member or HTU28 or HTU210 on a 2x6 carrying member for additional uplift capacity d � - Options:---,------------- --- - - d HTU may be skewed up to 67'/2'. See Hanger •Options on pp. 98-99 for allowable loads. • See engineering letter L-C-HTUSD at strongtie.com for installation with Strong -Drive® SD fasteners. Codes: See p.12 for Code Reference Key Chart Min. heel height per table Typical HTU26 Minimum Nailing Installation HTU26 gap between end of truss and carrying member HTU Installation for Standard Allowable Loads (for'/2" maximum gap, use Alternate Allowable Loads.) 1 Many of these products are approved for installation with Strong -Drive® SD Connector screws. See pp. 335-337 for more information. Standard Allowable Loads (1/8" Maximum Hanger Gap) Alternate Installation - HTU28 Installed on 2x6 Carrying Member (HTU210 similar) a Mln... Dimensions(in.)_ Fasteners.(in) DFISPAIIowabteLoads�- SPFIHFAIIowable'Loadsa° Model Code No Heel, Carrying �` Carved Uplift Floor;f Snow `Roof Wind Uplift � Floor' Snow Roof j Wmd Ref. Mehiber , Member (166) (100) (115), ,(125) �(160) .(160), (100} - (115) , (125) I (160) HTU28-2 HTU28-2 2x Sizes 0''/Z _I/a ',ohs I J"12',:(GU)'U.IbGXW/zj�L,U),U1425XtV2 1 ,A;gOO /441.11 aA�4 wv IBC, 37/a 15/a 71A6 31/2 (26) 0.162 x 3'/2 (14) 0.148 x 1'/x 1,235 3,820 3,895 3,895 3,895 1,060 2,865 1 2,920 2,920 2,920 FL, 71/4 15/a 7'1A6 3'h (26) 0.162 x 3'h (26) 0.148 x 1'h 2,020 3,820 4,315 4,655 5,435 1,735 3,285 ,i �10 4,005 4,675 LA 371a . i �a 9'fia :3'%2 ` '(32) 0:162X 3�h.) {14) 0148X 1''h. -.7,330 4 3rj0 ;3 0 300. ' a3 u, •1,145'° 3 225; i' 3,225 "'3 225 -,6,225`>' 15/a VAS 31/2 (32) 0.162'0,_ {32) 0148 x 1''h. 3;31 ')>4,705,� ,"a1tY .,130 .5 995 `;2,850 " 4,045;1 u� i ��4, nv0 5,155 Double 2x Sizes 37fa='"`33is 534 3'/z'�(20)'0.162:0"h '(14) 046;X3 1,515 2,940; 3;3261,0 0, a3910 ,1,305- 1,850_),2,090�'�2;255.2;465, 5'h - 35i s', 5�fa 3'h ; (20) 0.162:x 3'h; _ (20) 0.148 X3. ' `•2,175 ; 2,Q40 ' 3.32u 80 „4 zBC� 1;87,0 " '2,530< 2,8H T' 38 ,, 1,855'�i 37A 35/ia 7'/ts 31h (26) 0.162 x 31h (14) 0.148 x 3 - 1,530 3,820 4,310 4,310 4,310 1,315 2,865 3,235 13,235 3,235 IBC, FL, 71/4 35/1a 7'/,a 3Yz (26) 0.162 x 3'h (26) 0.148 x 3 3,485 3,820 4,315 4,655 5,825 2,995 3,285 77 LA 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch. 3. Upfift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 4. Wind (160) is a download rating. 5. For hanger gaps between'/a" and'h", use the Alternate Allowable Loads. B. Truss chord cross -grain tension may Emit allowable bads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie® Connector Selector" software includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 1'h" nails in the header and reduce the aflowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad. 8. Fasteners: Nail dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener information. 96 Simpson Strong -Tie® Wood Construction Connectors W Face -Mount Truss Hanger (cont.) l Many of these products are approved for installation with Strong -Drive® SD Connector screws. See pp. 335-337 for more information. Alternate Installation Table for 2x4 and 2x6 Carrying Member 1. See table above for dimensions and additional footnotes. 2. Maximum hanger gap for the alternative installation is 1h". 3. Wind (160) is a download rating. 4. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. Alternative Allowable Loads.(1/2" Maximum Hanger (3ap) Single 2x Sizes _ HTU28 (Min.) 37/a - 15/a - ., 71A6 31h -• (26) 0.162 x 1/2 (14) 0.148 x 1 l/z 1,110 3,770 3,770 3,770 3,770 955 2,825 2,825 2,825 2,825 FL, HTU28 (Max.) 71/4 15/a 71/is 31/2 (26) 0.162 x 31/2 (26) 0.148 x 11/2 1,920 3,820 4,315 4,655 5,015 1,695 2,865 3,235 3,490 3,765 LA Hl U210 (Min,) , ° 3'la 1S/8 9�s . 31h (32} 0162 x,3112 (14} 014$ x 1112 1,250 3 60Q 3 600 3 60[i 60C} r' 7,075 .2,700 2 700 2,?Of3 HT11210 (Max) a 9114 1/a 9S g''� 31h ,32j 016? i('112 {32� 0 38 x �'/zi ' 355 -" 7{35 5 02QA(i20 5 020',• 2 $OA o 3,530 3,$5 3�i65 3765 Double 2x Sizes HTU26 2 (Mtn) ' T'la 3 a 5'1,6 3% ,(20) 0162 x 311z (14j 0 U4 x 3 1 515. 2 340 a S O 3 500 T 00'', 1,305""2, 205 2;2050 2x205. 2 205` HTU26 2{Max } ' S . 31e 5'/+a = 31h (20) 0 if 2 X 3"/2 „ , (2D) tl 148 x T • 1,910 2 940 1;30 U? 504 3 5f10 1,645 ; 2 205 , 2,205 2 205 2 205 HTU28-2 (Min.) 37/a 35/ts 71/1a 31/2 (26) 0.162 x 31/2 (14) 0.148 x 3 1,490 3,820 3,980 -3,980 3,980 1,280 2,865 2,985 2,985 2,985 IBC, FL, HTU28-2 (Max.) 71/4 T5/ia 71/1e 31/2 (26) 0.162 x 31/2 (26) 0.148 x 3 3,035 3,82 44,315 4,655 5,520 2,610 2,865 3,235 3,490 4' 40 LA 1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member. 2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch. 3. Upfift bads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern. 4. Wind (160) is a download rating. 5. For hanger gaps between Us" and 1h", use the Alternate Allowable Loads. 6. Truss chord cross -grain tension may Emit allowable bads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie® Connector Selector® software includes the evaluation of cross -grain tension in its hanger allowable loads. For additional information, contact Simpson Strong -Tie. 7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 11/2" nails in the header and reduce the allowable download to 0.70 of the table value: The allowable uplift is 100% of the table bad. 8. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information. 19 Simpson Strong -Tie® Wood Construction Connectors SIMPSON Medium -Duty Face -Mount Hangers HU/HUC hangers may be installed on a masonry/concrete wall as described below. Additionally, HU hangers with one flange concealed may be installed similarly. HU and HUC products are heavy-duty face -mount joist hangers made from 14-gauge galvanized steel. • The HUC is a concealed flange (face flanges turned in) version of the HU. • HU is available with both flanges concealed, provided the W dimension is 25/16" or greater, at 100% of the table load. Specify HUC. • HU is available with one flange concealed when the W dimension is less than 25/16' at 100% of the table load. Specify as an 'X' version and specify flange to conceal. • For any HU or HUC shown in this catalog, the user may substitute all face nails with x 13/a" Titen® 2 screws (Model 1TN2-25134H) for concrete and 'A' x 2344` Titen 2 screws (Model T TN2-25234H) for GFCMU. Follow all installation instructions and use the loads from the sawn lumber or E NIP sections. Material: 14 gauge Finish: Galvanized; ZMAX® and stainless steel available. Installation: • Attach.the hangers to concrete or GFCMU walls using hex -head Titen 2 screws. Titen screws for GFCMU ('/a" x 23/a" — Model 171\12-252341­1) and for concrete CA" x 13/a" — Model TTN2-25134H) are not provided with the hangers. • Drill the 3/1e°-diameter hole to the specified embedment depth plus'/2': • Altematively, drill the 3/16'-diameter hole to the specified embedment depth and blow it clean using compressed air. • Caution: Oversized -diameter holes in the base material will reduce or eliminate the mechanical interlock of the threads with the base material and will reduce the anchor's load capacity. • Titen Installation Tool Kits are available. They include a M6" drill bit and hex -head driver bit (Model TTNT01-RC); a 3/16" x 41/2" drill bit is also available (Model MD1318412). • A minimum edge distance of 11/2" and minimum end distance of 37/3" is required as shown in Figure 1 for full uplift load. • Where no uplift load is required, a minimum end distance of 11/2" is permitted. Codes: See p.12 for Code Reference Key Chart Concealed flanges I J HUC410 e„. Viz` m HU214 Figure 1 — HUC410 Installed on Masonry Block End Wall Figure 2 — HUC410 Installed on Masonry Block End Wall 23 HU/HUC/HSUR/L Medium -Duty Face -Mount Hangers (cont.) 15 These products are available with additional corrosion protection. For more information, see p.15. A 0- ,' Model , = • - :. -- "Fasteners M... C) 5 uv Lo ads AF/Concrete Gode„r GFGM(jlo�able Standard Concealed GFCMU Titen� 2 Concrete Tden� 2 Joist Uplift {1fi0) Down (100/125) Uplift (160) R :Down (i001125) HU26 HU26X (4)1/4 x 23/4 (4) 1/4 x 13/4 (2) 0.148 x 11/2. 335 1,000 335 1,545 HU28 '7604 H62 (6)!4 ., 4 400 HU24-2 HUC24-2 (4)1/4 x 23/4 (4)1/4 x 13/4 (2) 0.148 x 3 380 1,000 380 1,545 HU26 2 (Mm) HUC26 2 (8)?/a x 23/a (8) %d x :13/4 (4) 0148 x 3 7&0 2 000, 760 3,200 HU26 2 (Max) HUC26 2 _. . f,. 12 „lax 2 /a ( ) +` 3 .-, (12)1I4 x131a..• . (6) 014$z� 3 11353,000 .. . ,.:, .... 1•,135 3 950- HU26-3 (Min.) HUC26-3 (Min.) (8) IA x 23/a I (8)1/4 x 1 3/4 (4) 0.148 x 3 760 2,000 760 3,200 HU26-3 (Max.) HUC26-3 (Max.) (12)1/4 x 23/4 (12)1/4 x 13/4 (6) 0.148 x 3 1,135 3,000 1,135 3,950 HU28-2 (Min.)-- ', HUC28= (Mm } '`` (10) %a x 23I4 . (10)1/4 x 13/a (4) 0 748 X 3 760 r _. 2 5pp 760 3 725 - HU28-2 (Max) " HUC2$=2 {Max } (I4)"Y%4 x 2�a (.14);1/a x 131a (6) 01q$"k`3 1135 3,50Q 1,135 ' A' 920 ' HU210 HU21 OX (8)1/4 x 23/4 (8) % x 13/a (4) 0.148 x 11/2 545 2,000 760 2,415 HU210 2 (Min,j HUC21a 2 (Min } ° ; ;(14} 1/a x 23/4 ; {14)114 xa13/a (6) 0148-x 3 7135 3r500 1,135 4,9 20:' HU210:2 (Max) _ HUC210 2 (Max) "- (18)11a x 23/4 1 {18)1la X 13/a (10) 014$ X 3 i`800 ` 4 500� 1;$00 5,085 HU210-3 (Min.) HUC210-3 (Min.) (14)1/4 x 23/4 (14)1/4 x 13/4 (6) 0.148 x 3 1,135 3,500 1,135 4,920 HU210-3 (Max.) HUC210-3 (Max.) (18)1/4 x 23/4 (18)1/4 x 13/4 (10) 0.148 x 3 1,800 4,500 1,800 . 5,085 HU212--' HU212X �„ ",-"(10)1/ax 234YaiX-13/a {6) 0148 x 11h 1135 2 500 < 1,1�35 2 665 HU212-2 (Min.) HUC212-2 (Min.) (16)1/4 x 23/4 (16)1/4 x 13/a (6) 0.148 x 3 1,135 4,000 1,135 4,920 HU212-2 (Max.) HUC212-2 (Max.) (22)1/4 x 23/4 (22)1/4 x 13/4 (10) 0.148 x 3 1,350 5,085 1,350 5,085 HU2,12-3 (Min), -'' r HUG212 3 (Min }- X13/a HU212-3 (Max } ' HUC2,12 3 (Max.) ' (22) ?Ia x 23/4 "-'- (22} 1/a x 13/4 (i p) 0:148 x 3 800 -, 5,085 ` 1;800 5 085 - HU214 HU214X (12)1/4 x 23/4 (12)1/4 x 13/4 (6) 0.148 x 11h 1,135 2,665 1,135 2,665 HU214 2 {Mm) HUC2i4 2 (Min) (18) ✓4 x 23/a '`" {18�,Ya xi?/a (8) 0148 x 3 7,515 4 504 ' HU214 2 Max. .` ( ) ' HUC21'4 2 {Max24)?lax 23/a ? 3 (24) / -7G1 /a .. `} Ol b .. .,5 A85 �. .215 HU214-3 (Min) HUC214-3 (Min.) (18)1/4 x 23/4 (18)1/4 x 13/4 (8) 0.148 x 3 1,515 4,500 1,515 5,085 1. HU214-3 (Max.) HUC214-3 (Max.) (24)1/4 x 23/4 (24)1/4 x 13/4 (12) 0.148 x 3 2,015. 5,085 2,015 5,085 HU216 HU216X (18)`7/4 x 23/4 -. " {18) Ya x13/a, ' (8) 0.148.X 11h 2 92A 1,515 2.920 € " HU216-2 (Min.) HUC216-2 (Min.) (20)1/4 x 23/4 (20)1/a x 13/4 (8) 0.148 x 3 1,515 4,920 1,515 4,920 HU216-2 (Max.) HUC216-2 (Max.) (26)1/4 x 23/4 (26)1/4 x 13/4 (12) 0.148 x 3 2,015 5,085 2,015 5,085 HU21fi;,3(Mm}:' HUC2163(Min} `... (20)*ijax2*4 ; a� (20)1/4x13/a >(8)0198x3 --------------- 1,515 492A 1,515 -� 4920" �. HU216 3 (Max:j HUG216 3 (Max) (26) -1/4 x 23/a (26)1/a x.13/d (1Z) O 14$ x 3 ' 2 015, ; ?5 A85°= 2,015 5 085 HU7 (Min.) (Not available) (12)1/4 x 23/4 (12)1/4 x 13/4 (4) 0.148 x 11h 545 2,980 760 2,980 HU7 (Max.) (Not available) (16)1/4 x 23/4 (16) 1/4 x 1 3/4 (8) 0.148 x 11/2 1,085 3,485 1,085 3,485 HU9 (Min) (Not avaUable)" , (1$},1/4 x 23/a (18)1!4 X)13/a . (6) 014$ X, 1h 1113 , .. 3 230 5 Ih35 3 230 HU9(Maxj �,;� {Nota+raitable) (24}11ax23Ja q. (24)1/dX1ae{10)0I�1$x',11/z 14453735- 1,445 K- 3735 HU11 (Min.) (Not available) (22)1/4 x 23/4 I (22)1/4 x 13/. (6) 0.148 x 11/2 1,135 3,230 1,135 3,230 HU11 (Max.) (Not available) (30) 1/4 x 23/4 I (30)1/4 x 13/4 (10) 0.148 x 11/2 1,445 3,735 1,445 3,735 23 (28} 1/ xaHU14^(Min) 11 1'h 148Noava 1 515 3 485 ° 1,fi15 3,485, HU14•{Max} {Not available) (36j1fax23la <°, x(36111ax13/4y �,(14)0.948x11h 20154245�� 20�5s, i4,245p, 38 UPLIFT/SHEAR ANCHOR r-V EACH TRU55 - SEE B/SKI PLAN NOTE: ADD'L FRAMING NOT SHOWN FOR CLARITY RAISED HEEL TRUSS BEARING A SCALE. NTs SKI f 1, r ED HEEL ROOF TRUSSES PLAN RIBBON BOARD- SEE SCHEDULE FOR SPACING a FASTENING TO TRUSSES i �'\—MASONRY WALL - SEE PLAN' 9` r ;ram B..�J I ��� ROOF SHEATHING- SEE PLAN RAISED HEEL ROOF TRUSSES -SEE PLAN SOFFIT/FASCIA- SEE ARCH. =` W RIBBON BOARD- N O ¢ Q 3 SEE SCHEDULE U Z LL FOR SPACING a Zp oe w w w FASTENING TO W N U:2 Q Q TRUSSES w - 8 zO �M WALL SHEATHING -SEE PLAN = w 3 MIN. 15/32' GDX PLYWOOD OR I 1/16' 055 WITH 8d GUN NAILS U (0.131' X 2 1/29 O V O.G. TO UPLIFT/SHEAR GYP. CEILING - RIBBON BOARDS ANCHOR EACH SEE PLAN a TRUS5- SEE PLAN SCHEDULE ,m a DO NOT FASTEN RIBBON BOARD INTO END GRAIN OF ROOF TRUSS MASONRY WALL - BOTTOM CHORD SEE PLAN m W�"\"'ON: RAISED HEEL TRU55 BEARING B SCALE, NTS SKI RIBBON 5GHEDULE, DESIGN CRITERIA RIBBON MATERIAL RIBBON SPACING RIBBON ATTACHMENT Vull=165 MPH (2) 12d GUN (0.131' X 3') (Yasd:128 MPH) 2X4 5PF02 24' TO EACH TRUSS, (4) EXP. B, NAILS AT JOINTS ENCLOSED Yult-180 MPH (2) 12d GUN (0.131' x 3') (Vasd=139 MPH) 2X4 SPF02 16, TO EACH TRUSS, (4) EXP. C, NAILS AT JOINTS ENCLOSED SHUT TITLE: .—DE ' - —EO NEEI ROOFIPoIeefd SHEET INFORMATION: JOB NO-- ]ellld DfiF ISSUED: II.BB.Id OR.YYM BY: f!EVIEWFDBT: SK.1 ALPI NE , WIIWC6,WA N.Y' January -10',,:.2ff20' .Carpenter ,'C'diittaitt6t,,s 6fAmerica, Inc:.. Q ule G W , Winter,.H`aven;. F-L'33880-'620I Dear Matt: ... Z. - " , �! It has crimetomy aftentionl'ihat,some questions were raised concerning -s diameter, holes .drzlIed thiru the chords iam fac e) co),qf' ys42 gable end trusses tq, allow for' threaded rods used for "tie downs " If ahese.gableends:are over continuous supp;orti w th one face fully sheathed and the'151 di.-Ilt .:� 6, et-d A ittlM.-zenfer4n f" face A6 close: ,; Ian; al:es..Or verticaI,,Yvqb4 then; narer)a!frs.reia-iffrod.- The buss on!y s ipports-2%feet-Offlobtlt dA ',-and-hodddition4l load4, Ifybu have any qu&ftidh§. Please give me -a -,call, sincerely; Y; 6750 �F6pupibri,Ve,. 96ife 306. Nando, FL 328. 2J (OQQ) 5?1 - -' -97RO -(863),42278685 . w e tY0'qllr ww"'Eift c m; " I;- pilpi 7rUSdQGuneit has been eleGtdCl c* sigoW Alpine, an ITW Company >�Se dtt nga[49RWa�#Ptl0d 6750 Forum Drive, Suite 305 cgAeS Wif110tA W vigind siorwA f'8 mistbe Orlando, FL 32821 vefined using" odgilu 1 e#emotic wBion. ALPINE Phone. (800)755.6001 -'W0ft"k%1w t ANITWCOMPann www.alpineitw.corn ,,, H ........." a No. T,t28�51 � � y STATE s COA #0 278 03/05J2021 Custoiner'. Carpenter Contractors of America Job Number. N334496 Job Des✓iption: 7A5,320 ,182EC,E ,R101 / 1828/CAL!/4EBB ELEV.C/E Address: nee! , Design Code: FBC 7th Ed: 2020 Res tntel/iVIEW Version; 20.02.00A JRef#: 1X3G89750070 Wind Standard., ASCE 7-16 Wind Speed (mph): 160 Design Loading (pst): 37.00 Buildin T e: Closed This package contains general notes pages; 24 truss drawing(s) and 4 detail(s). ltecrir ` I3+•aw►rtg•Nant�er~ � Tr'ais� ,<= .. � ,w � � 1 064.21.1307.55475 Al 3 064.21.1307.54913 A2 5 064.21..1307.55443 A4 7 064.21.1307.53068 A6 9 064.21.1307.554444 A8 11 064.21.1307.53054 A10 13 064.21.1307.55100 A14G 15 0644.21.1307.54553 A13 17 064.21.1307.53506 A16 19 064.21.1307.54397 CiGE 2.1 064.21.1307.54695 CJ5 23 064,21.1307,55693 CJ1 25 A16015ENC160118 27 VAL180160118 2 064.21.1307.55365 A1A 4 064.21.1307-53037 A3' 6 064 21.1307..53053 A5 8 064.21.1307.54538 A7 10 064.21.1307,55225 A9 12 064.21.1307-54694 Al2 14 064.21.1307.55412 All 16 064.21.1307.55678 A15 18 06411.1307.53600 B1GE 20 064;21.1.307.54350 EJ7 22 064.21.1307,54303 1 CJ3 24 064.21.1307.53850 HJ7 26 GBLLETIN01'18 28 VALTN160118 Florida Ced&r-ate of Product Approval #171-1999 Printed 3/5/2021 1`11:49 PM General Notes Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities: The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1, Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to independently verify the accuracy or completeness of the information provided by others and may rely on that information without liability. The responsibility for verification of that information remains with others neither employed nor controlled by the Truss Design Engineer. The Truss Design Engineer's seal and signature on the attached drawings, or cover page listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component designs and not for the technical information furnished by others which technical information and consequences thereof remain their sole responsibility. The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and loads for each truss component match those required by the plans and by the actual use of the individual component, and for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any additional factors required in the particular application. Truss components using metal connector plates with integral teeth shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to exceed 19% and/or cause corrosion of connector plates and other metal fasteners. The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss component design loads, inspection of the truss components before or after installation, the design of temporary or permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports, installation of the truss components, observation of the truss component installation process, review of truss assembly procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in the installation of the truss components and/or its connections. This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request. Temporary Lateral Restraint and Bracing: Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2, B7 and/or 1310 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to and may not be relied upon for the temporary stability of the truss components during their installation. Permanent Lateral Restraint and Bracing: The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional. These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building Designer. Connector Plate Information: Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations, gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60. Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at www.icc-es.oro. Fire Retardant Treated Lumber: Fire retardant treated lumber must be properly re -dried and maintained below 19% or less moisture level through all stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special handling care must be taken to prevent breakage during all handling activities. Page 1 of 3 General Notes (continued) Key to Terms: Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be found in calculation sheets available upon written request. BCDL = Bottom Chord standard design Dead Load in pounds per square foot. BCLL = Bottom Chord standard design Live Load in pounds per square foot. CL = Certified lumber. Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot. FRT = Fire Retardant Treated lumber. FRT-DB = D-Blaze Fire Retardant Treated lumber. FRT-DC = Dricon Fire Retardant Treated lumber. FRT-FP = FirePRO Fire Retardant Treated lumber. FRT-FL = FlamePRO Fire Retardant Treated lumber. FRT-FT = FlameTech Fire Retardant Treated lumber. FRT-PG = PYRO-GUARD Fire Retardant Treated lumber. g = green lumber. HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches. HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep adjustment. HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds. Ic = Incised lumber. FJ = Finger Jointed lumber. L/# = user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value. L/defl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the referenced panel point. Reported as 999 if greater than or equal to 999. Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection. Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases. Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases. Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases. NCBCLL = Non -Concurrent Bottom Chord design Live Load in pounds per square foot. PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds. PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds. PP = Panel Point. R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc). -R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc). Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the indicated location (Loc). RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). Rw = maximum downward design Reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the identified location (Loc). TCDL = Top Chord standard design Dead Load in pounds per square foot. TCLL = Top Chord standard design Live Load in pounds per square foot. U = maximum Upward design reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the indicated location (Loc). VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in inches. VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment. VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load. VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment. W = Width of non -hanger bearing, in inches. Refer to ASCE-7 for Wind and Seismic abbreviations. Uppercase Acronyms not explained above are as defined in TPI 1 Page 2 of 3 References: 1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.org. 2. ICC: International Code Council; www.iccsafe.orq. 3. Alpine, a division of ITW Building Components Group Inc.: 514 Earth City Expressway, Suite 242, Earth City, MO 63045; www.alpineitw.com. 4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.org. 5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindustU.com. Page 3of3 SEQN: 249564 / COMN Ply: 1 FROM: RWM Qty: 11 6'1 "7 6'1"7 Job Number: N334496 ,7A5/320 ,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E Truss Label: Al 12'11"15 I 19'10" + 26'8"l 6'10"8 6'10"1 610"1 5X5 E 39'8" Cust:R8975 JRef:1X3G89750070 T10 D rw N o: 064.21.1307.55475 SSB / YK 03/05/2021 33'6"9 39'8" 617 1' 10' 91101. 9'10" F 10' + 19,101, 29'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pfin PSF) Defl/CSI Criteria TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in lac L/defl U# TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.222 K 999 360 BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.385 K 999 240 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.081 J - - Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.140 J - Building Code: NCBCLL: 10.00 Mean Height: 15.00 ft TCDL: 4.2 psf Creep Factor: 2.0 Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.617 Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.882 Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.457 Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): VIEW Ver: 20.02.00A.1020.20 Wind Duration: 1.60 WAVE Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W4,W5 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. y4ttittltttUOttr����`+' Loading �� �• r�`'�'fri, Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance., �+'� �'� �/®e•°O' r�O°•.• �/ ���� +� •• °°°\eJ e Wind °• ' .: Wind loads based on MWFRS with additional C&C i member design. e Wind loading based on both gable and hip roof types. SAT ,,,a:• • ac, r °•rr e•rre •♦ �`ti� /01 COA t'i �ow"W 03/05/2021 m b 10, 1' 39'8"i ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 1711 /- /- /961 /309 /444 H 1711 /- /- /961 /309 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 2.0 H Brg Width = 8.0 Min Req = 2.0 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1490 - 3155 E - F 1130 - 2029 C - D 1366 - 2875 F - G 1366 - 2875 D - E 1130 - 2029 G - H 1490 - 3155 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - L 2759 -1207 K - J 2278 - 858 L - K 2278 - 879 J- H 2759 -1186 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. L - D 541 -134 K - F 530 - 745 D - K 530 - 745 F - J 541 -134 E - K 1362 - 605 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigid ceiltn Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply Oates to each face of truss and position as shown above and on the Joinf Details, unless noted otherwise. Defer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildinq_ Components Group Inc. shall not,be responsible for any deviation from this drawing, any failure to build the ANR COMP Y truss in conformance with ANSI TP1 1, or for handling, shipping,, installs ion. and bracing of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional en sneering responsibilitty� solely gor the design shown. The suitablli y and use of [his Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSUTPI 1 Sec.2. Orlando FL, 32821 For more information see these web sites: Alpine: aloineilw.com: TPI: toinst.oro: SBCA: sbcinduslrv.com; ICC: iccsafe.orq; AWC: awc.org SEQN: 249588 / COMN Ply: 1 Job Nber: N334496 Cust: R 8975 JRef:1X3GB9750070 T25 / FROM: RWM Qty.. 1 ,�7A5/370,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.55365 Truss Label: A1A SSB / WHK 03/05/2021 17122 23'83108"44 I 398 8177'1111••22 5"14 24T11"2 =5x5 F 39'8" 11 1�2 6'8" 80"11 T11"5 1' FI 8'1"9 12'10"4 14'1 23'8" 31'8"11 i17 1T Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Des Ld:: 37.00 Mean Height: 15.00 ft TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; T1 2x4 SP #1; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; W6,W8,W9,W11 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2ff%min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. + Bottom Chord section between vertcials may be removed. Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.280 P 999 360 VERT(CL): 0.522 P 905 240 HORZ(LL): 0.120 K - - HORZ(TL): 0.225 K - Creep Factor: 2.0 Max TC CSI: 0.790 Max BC CSI: 0.859 Max Web CSI: 0.964 Ver: 20.02.00A.1020.20 • �• � i o- 7,08 1 �t ! ,, SAWO.,. � COA ZNA� ,N 03/05/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 1555 /- /- /960 /309 /444 1 1555 /- /- /961 /309 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 2.2 1 Brg Width = 8.0 Min Req = 2.2 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1413 - 2747 F - G 1409 - 2067 C - D 1715 - 3278 G - H 1217 - 2103 D - E 1437 - 2551 H - 1 1424 - 2775 E - F 1565 - 2527 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - S 2374 -1111 L - K 2401 -1108 Q - M 2867 -1216 K - 1 2404 -1107 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - S 508 - 838 M - F 1684 - 892 C - Q 637 -122 M - L 1745 - 573 S - Q 2530 -1181 F - L 559 - 464 Q - D 744 - 323 L - G 450 - 365 D - M 533 - 912 L - H 477 - 691 **WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI.. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached ri id ceilmp Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 610, as applicab a. Apply plates to each face of truss and position as shown above and on the Join�Detalls, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildinq_ Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the AurtwcornaAur truss in conformance with ANSI/TP) 1, or for handling, shipping,, installation. and bracing of trusses. A seal on this drawing or cover pa gpe 6750 Forum Drive listing this drawing indicates acceptance of professional en ineenng responsibility solely -for the design shown. The suitability and use ofuls Suite 305 drawing for any structure is the responsibility of the BuildingPesigner per ANSI/TPI 1 Sec.2. For snore information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249589 / HIPS Ply: 1 Job Number: N334496 Cust: R 8975 JRef:1X3G89750070 T9 / FROM: RWM Qly: 1 ,7A5/320 ,182EC,E ,R101 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.54913 Truss Label: A2 SSB / WHK 03/05/2021 6'1 "7 12'6"15 19, 6'1"7 6'S"8 6'51 r b o> 10' Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 It NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: h to 2h Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W4,W5,W6 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 271"'1 33'6"9 39'8" 651 6'5"8 6-17 :5X5=5X5 E F 39'8" 9'10" 19'10" i 29'8" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf., NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.172 L 999 360 VERT(CL): 0.321 L 999 240 HORZ(LL): 0.066 K - - HORZ(TL): 0.123 K - Creep Factor: 2.0 Max TC CSI: 0.480 Max BC CSI: 0.747 Max Web CSI: 0.625 VIEW Ver: 20.02.00A.1020.20 03/05/2021 10, r 39'8"+ ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1556 /- /- /963 /310 /427 1 1556 /- /- /963 /310 P Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.8 1 Brg Width = 8.0 Min Req = 1.8 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1542 - 2800 F - G 1182 -1779 C - D 1425 - 2521 G - H 1425 - 2521 D - E 1182 -1779 H - I 1542 - 2800 E - F 1159 -1559 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - M 2444 -1262 L - K 2030 - 937 M - L 2030 - 957 K - 1 2444 -1241 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - D 508 -119 L - F 548 - 356 D - L 521 - 683 L - G 521 - 683 E - L 548 - 356 G - K 508 -119 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT"" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, Installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSL Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin Installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each faceof truss and position as shown above and on the Join Details, unless noted otherwise. f�efer to ALPINE drawings 160A-Z for standard plate positions. Refer to jobs General Notes page for additional information. Alpine, a division of ITW BuildincL Components Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the -CO A. truss in conformance with ANSI/TPI 1, or for handling, shipping,. Installation and bracing of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engmeenng responsibilityy solely -for the design shown. The suitability and use of This Suite 305 drawing for any s9ructure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC:awc.org Orlando FL, 32821 SEQN: 249590 / HIPS Ply: 1 Job Number: N334496 Cust: R 6975 JRef: 1 X3G89750070 T22 / FROM: RWM Qty: 1 ,7A5/320 ,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.53037 Truss Label: A3 SSB / WHK 03/05/2021 12'0"15 18'0"1 217"1 6'1'7 5'11"9 5'11"2 3714 ;5X5 =5X5 E F 39'8" 10' + 9'10„ 10' 19,10" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA BCDL: 10.00 Risk Category: II Snow Duration: NA EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Building Code: Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 WAVE Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W4,W5,W6 2x4 SP #2 N; Bracing (a) 1 X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. 27'7"1 33'6"9 + 39'8" 5'11"2 5'11"9 617 91101, 29'8" Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.171 L 999 360 VERT(CL): 0.319 L 999 240 HORZ(LL): 0.066 K - - HORZ(TL): 0.124 K - Creep Factor: 2.0 Max TC CSI: 0.408 Max BC CSI: 0.748 Max Web CSI: 0.485 VIEW Ver:20.02.00A.1020.20 Wind'` f-4. Wind loads based on MWFRS with additional C&C tp `�+•+■••"•■■..�'�� member design.! ���r,`,E �• Wind loading based on both gable and hip roof types. 4' •' �'• • o. 708 1 . ww 'w COA ONAIL �G ,• 03/05/2021 10, 1' 39'8"+ ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 1556 /- /- /965 /312 /407 1 1556 /- /- /965 1312 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.8 1 Brg Width = 8.0 Min Req = 1.8 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1608 - 2796 F - G 1252 -1794 C - D 1497 - 2523 G - H 1498 - 2523 D - E 1252 -1794 H - 1 1609 - 2796 E - F 1245 -1635 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - M 2439 -1329 L - K 2064 -1027 M - L 2064 -1048 K - 1 2439 -1308 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - D 495 -106 L - F 523 - 300 D - L 497 - 674 L - G 497 - 674 E - L 523 - 300 G - K 495 -106 "'WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attache U rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Joinf Details, unless noted otherwise. f�efer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not. be responsible for any deviation from this drawing, any, failure to build the A -COW - truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracingg of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional en ineenng responsibilitty�r solely for the design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the Buildinguesigner per ANSI/TPI 1 Sec .2. For mare information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ]CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEON: 249591 / HIPS Ply: 1 Job Number. N334496 Cust: R 8975 JRef:1X3G89750070 TS / FROM: RWM City: 1 ,7A5/320 ,182EC,E ,R101 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.55443 Truss Label: A4 SSB / WHK 03/05/2021 s fM b_ b 7'1014 1 17' + 22'8" 7' 10"14 9' 1 "2 68" io5X5 =5X5 D E 39'6" 31'9"2 39'8" 9' 1 "2 T1014 0, 1 offs" 10, 91101, 9110.1 10, 19,10" 29'8" Loading Criteria (psi) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.149 J 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.279 J 999 240 B 1552 /- /- /965 /318 /386 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.060 1 - - G 1552 A A /965 /318 /- EXP: C Kzt: NA Des Ld: 37.00 HORZ(TL): 0.112 1 Wind reactions based on MWFRS Mean Height: 15.00 it NCBCLL: 10.00 Building Code: CreepFactor: 2.0 B Brg Width = 8.0 Min Req = 1.8 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.760 G Brg Width = 8.0 Min Req = 1.8 Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.755 Bearings B & G are a rigid surface. Bearings B & li require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.989 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20 0 /10 0 () () Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 1673 -2755 E - F 1699 -2561 C - D 1698 - 2561 F - G 1674 - 2755 Top chord: 2x4 SP #2 N; T2,T4 2x4 SP 2400f-2.OE; D - E 1352 -1728 Bot chord: 2x4 SP #1; Webs: 2x4 SP #2 N; W1,W6 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) 1X4 #3SRI3 or better continuous lateral restraint to B - K 2393 -1373 J - 1 1695 - 842 be equally spaced. Attach with (2) 8d Box or Gun K - J 1695 -863 1 - G 2393 -1352 nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. Maximum Web Forces Per Ply (Ibs) (a) or scab reinforcement may be used in lieu of CLR Webs Tens.Comp. Webs Tens. Comp. restraint. substitute (1) scab for (1) CLR and (2) scabs C - K 498 -448 E - I 770 -435 for (2) CLR'S where shown. Scab reinforcement to be K - D 770 -435 I - F 498 -448 same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc.y{lltl►tflllp1f0����" Windy Wind loads based on MWFRS with additional C&C ,l� �'�r�� +��� /`�•.•*I�•+••o.: �� member design. Wind loading based on both gable and hip roof types. �5���✓ �'•��rj�G s�; • %.� �.• r ` �' +!F- �` o. 08 1 ' • SAT O ' COA 03/05/2021 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! '"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly attached rt id ceiling Locations shown for permanent lateral restraint of webs shall have bracm installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to ALPINE drawings 16OA-Z for standard plate positions. Refer to jobs General Notes page for additional information. Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing, anyfailure to build the nN mvcOrunrry truss in conformance with ANSl1TPI 1, or for handling, shipping,installation and bracinq of trusses. A seal on this drawinq or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibilit� solely -for the design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSI/TP1 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249592 / HIPS Ply: 1 Job Number. N334496 Cust: R 8975 JRef:1X3G89750070 T24 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,R101 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.53053 Truss Label: A5 SSB / WHK 03/05/2021 6'1 "7 16'0" 1 23'7" 15 33'6"9 39'8" 6' 1 "7 9'10" 10 7'7"14 9'101,10 6'1 "7 6X6 = 6X6 D E T2 12 T4 6 P -5X5 ;T o5X5 F 0o C 9) W W1 B G A H y- 4X6(A2) =-5X5 =5X5 =5X5=4X6(A2) 39'8" 10' 9'10" 9'10" 10, 1 �1. + + + 10' 19,10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pt. NA Ce: NA VERT(LL): 0.156 J 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.292 J 999 240 B 1556 !- /- /964 7713 /366 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.064 1 - - G 1556 /- /- /964 /713 /- EXP: C Kzt: NA HORZ TL 0.119 1 - Wind reactions based on MWFRS Des Ld: 7.00 () 3 Mean Height: 15.00 ft - 1.8 NCBCLL: 10.00 Building Code: Creep Factor: 2.0 B Br Width = 8.0 Min Re TCDL: 4.2 psf G Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 BCDL: 5.0 sf FBC 7th Ed. 2020 Res. Max TC CSI: 0.799 P Bearings B & G are a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.745 Bearings B & li require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.485 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCr 0.18 Plate T e s : pi: yP () Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B-C 1841 -2852 E-F 1665 -2513 C - D 1665 - 2513 F - G 1841 - 2852 Top chord: 2x4 SP #2 N; T2,T4 2x4 SP 2400f-2.OE; D - E 1456 -1829 Bot chord: 2x4 SP #1; Webs: 2x4 SP #2 N; W1,W6 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - K 2505 -1555 J - 1 1780 - 984 member design. K - J 1780 -1005 I - G 2505 -1535 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C-K 511 -469 E-I 617 -249 K - D 617 - 248 I - F 512 - 469 iy�tjt�tlultntuftple •� e a 0.708 1 a y s ,4 ;• SAT 0 •4 •: l � , lft#mp111N 03/05/2021 •'WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT"' FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing.. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bottom have bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and chord shall a properly Locations for lateral restraint of webs shall have bracing installed BCSI sections B3, B7 or B10 attached rigid ceiling shown permanent per as applicable. Apply plates to each face. of truss and position as shown above and on the Joint Details, unless noted otherwise. Defer to drawings 160A-Z for standard plate positrons. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Building Components Group Inc. shall not. be responsible for any deviation from this drawing, any, failure to build the RNI COWANY in ANSI/1 PI 1, for handling, bracingof trusses. A seal on this drawing or cover a truss conformance with or shipping,, installation and pa 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibilitty� solelyor the design shown. The suitability and use of This Suite 305 -Designer drawing for any structure is the responsibility of the Building per ANSI/TP1 1 Sec.2. For more information see these web sites: Alpine: al ine!tw.com; TPI: t insl.or ; SBCA: sbcindusl .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249593 / HIPS Ply: 1 Job Number: N334496 Cust: R8975 JRetlX3G89750070 T7 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.53068 Truss Label: A6 SSB / WHK 03/05/2021 71014 15, 24'8" 31'9"2 39'8" 7'1014 7'1"2 9'8" 7'1"2 T10"14 :6X6 = 6X6 D T3 E 12 6 ' C 5 \5 F SO5 o W m W1 B G t AIII H � 4X6(A2) =5X5 =5X5 =5X5=4X6(A2) 39'8" 9'10" 9110.. 10, + 10' 19,10" 29'8" +1'� + 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf. NA Ce: NA VERT(LL): 0.159 J 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.298 J 999 240 B 1552 /- /- /962 /328 /346 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.061 1 - - G 1552 /- /- /962 1328 /- Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.115 1 Wind reactions based on MWFRS Mean Height: 15.00 It BuildingB NCBCLL: 10.00 Cade: Creep Factor: 2.0 Br Width = 8.0 Min Re 1.8 9 q = TCDL: 4.2 psf Soffit: 0.00 FBC 7th Ed. 2020 Res. Max TC CSI: 0.913 BCDL: 5.0 psf G Brg Width = 8.0 Min Req = 1.8 Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.760 Bearings B & G are a rigid surface. Bearings B & li require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 It Rep Fac: Yes Max Web CSI: 0.474 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 itFTlRT:20 (0)/10 (0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 1807 - 2729 E - F 1827 - 2537 C - D 1826 - 2538 F - G 1807 - 2729 Top chord: 2x4 SP #2 N; T3 2x4 SP 2400f-2.0E; D - E 1539 -1910 Bot chord: 2x4 SP #1; Webs: 2x4 SP #2 N; W1,W6 2x4 SP #3; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - K 2363 -1483 J - 1 1847 -1110 member design. K - J 1847 -1131 I - G 2363 -1462 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - K 394 - 358 E - I 628 - 300 K - D 628 - 300 I - F 394 - 358 ' ���QiAtlfNi{lp�Jitifly/jI !fl 10' 1 1 • ¢t, o. T08 1 • • Z s T o J• ss� COA //t3 o NAL ECG 'ftft0 3/riliNlN 03/05/2021 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached ri id ceiling.Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, Refer as applicable. Apply plates to each face off truss and position as shown above and on the Joint Details, unless noted otherwise. drawings 160A-Z for standard plate positions. Refer to jobs General Notes page for additional information. to ALPINE Alpine, a division of ITW Buildin$gComponents Group Inc. shall not,be respponsible for any deviation from this drawing, any. failure to build the pN IWCDNYpNY truss in conformance with ANSI 1, or for handling, shipping,. installation. and bracing of trusses; A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibilityY solely -for the design shown. The suitability and use of this Suite 3o5 -Designer drawing for any structure is the responsibility of the Building per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t insl.or ; SBCA: sbcindust .com; [CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249594 / HIPS Ply: 1 Job Number. N334496 Cust: R 8975 JRef:1X3G89750070 T23 I FROM: RWM Qty: 1 7A5/320 ,182EC,E ,13101 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.54538 Truss Label: A7 SSB / WHK 03/05/2021 6'1"7 14'0"1 19'10" 25'7"15 336"9 39'8" r 6'1"7 + 7'10"10 + 5'915 + 5'9"15 7'10"10 6'1"7 5X5 1112X4 =5X5 D E F T2 12 T4 6 F,-,- W C 5 5X5 G W3 B H A � 4X6(A2) -5X5 =5X8 =5X5 =4X6(A2) 39'8" 10' 9'10" 91101, 10' 1'. �1' 10' 19,10., 29'8" 39'8" Loading Criteria (psi) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.176 E 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.329 E 999 240 B 1556 /- /- /958 /715 /325 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.065 J - - H 1556 /- /- /958 /715 /- Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.121 J Wind reactions based on MWFRS Mean Height: 15.00 ft Building p q = NCBCLL: 10.00 g Cade: Creep Factor: 2.0 B Brg Width = 8.0 Min Re 1.8 TCDL: 4.2 psf H Br Width = 8.0 Min Re 1.8 Soffit: 0.00 FBC 7th Ed. 2020 Res. Max TC CSI: 0.743 g q = BCDL: 5.0 sf P Bearings B & H are a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.748 Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.434 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 it FT/RT:20(0)/l0(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 B - C 1975 -2822 E - F 1780 -2112 Lumber C - D 1821 - 2515 F - G 1821 - 2515 Top chord: 2x4 SP #2 N; T2,T4 2x4 SP #1; D - E 1780 -2112 G - H 1975 -2822 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - L 2470 -1666 K - J 1912 -1210 member design. L - K 1912 -1231 J - H 2470 -1645 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - L 439 - 395 F - J 556 -182 L - D 556 -182 J- G 439 - 395 E - K 440 -281 ��Ay11�t1tlft0iNflrl►lrj� • i o. / 08 1 • • II• „� �; SAT 0 •: � AK• ek 1 ,••`�• caw, iV ALA ���`• COAA (3/05/2021 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing BCSI. Unless top have structural sheathing and bottom chord shall have a per noted otherwise, chord shall proper)v attached properly attacheU rigpid ceiling Locations shown for permanent lateral restraint of webs shall have bracingg installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face. of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to jobs General Notes page for additional information. ALPINE Alpine, a division of ITW Buildin Components Group Inc. shall not.be responsible for any deviation from this drawing, any, failure to build the pNRWCOMCRNY ANSIi9 PI 1, for handling, bracing trusses. A this drawing truss in conformance with or shipping,. mstallation.and of seal on or cover pate 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibili((�� solely -for the design shown. The suitability and use ofisSuite 305 -Designer ANSI/TPI 1 Sec.2. drawing for any structure is the responsibility of the Building per For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindusl .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 2495951 HIPS Ply: 1 Job Number: N334496 Cust: R 8975 JRef:1X3G89750070 T6 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.55444 Truss Label: A8 SSB I WHK 03/05/2021 1'23' 19,101, 2"0"2 3 99„84 i i 66'10" +' 'I 612 2 5X5 III2X4 =5X5 D E F 12 6 �2X4 W p2X4 M C 0 G 1O o W3 B H A s a I �8'8" 4X6(A2) -5X5 =5X8 =5X5 =4X6(A2) 39'8" 1' 10' 9'10" 9'10" T 10, 1' 10' 19,10" 29'8" 39'6" Loading Criteria (psi) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in ]cc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.191 E 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.357 E 999 240 B 1556 /- /- /953 /716 /305 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.065 J - - H 1556 /- /- /953 /716 /- EXP: C Kzt: NA Des Ld: 37.00 () HORZ TL : 0.121 J Wind reactions based on MWFRS Mean Height: 15.00 ft NCBCLL: 10.00 Building Code: Creep Factor: 2.0 TCDL: 4.2 psf B Brg Width = 8.0 Min Req = 1.8 FBC 7th Ed. 2020 Res. 0 TC CSI Soffit: 0.00 BCDL: 5.0 psf Maxs. : . H Brg Width = 8.0 Min Req = 1.8 Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.754 Bearings B & H are a rigid surface. Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.687 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 2014 - 2780 E - F 1973 - 2289 C - D 1925 - 2523 F - G 1925 - 2523 Top chord: 2x4 SP #2 N; D - E 1973 -2289 G - H 2O14 -2780 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - L 2421 -1686 K - J 1982 -1323 member design. L - K 1982 -1344 J - H 2421 -1665 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - L 381 - 339 K - F 425 - 401 L - D 535 -183 F -J 535 -183 D - K 425 - 401 J - G 381 - 339 V00sN161111 ku► E - K 585 - 391 0. 7,08 1 • ..o :• SAT O tNAL COA I � 'utrearP»n1000 (3/05/2021 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition for of BCSI (Building Component Safety Information, by TPI and SBCA) safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attachetl rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections as applicable. Apply Oates to each face of truss and as shown above and on the Join Details, unless noted otherwise. B3, B7 or B10, Refer to position drawings 16OA-Z far standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Building Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the co ,U truss in ANSI/TPI 1, for handling, bracing trusses. A seal on this drawing or cover conformance with or shipping,, installation and of page 6750 Forum Drive listing this drawing indicates acceptance of professional enmineenng responsibility solely -for the design shown. The suitability and use of this Suite 305 -Designer drawing for any structure is the responsibility of the Building per ANSIITPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ]CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249596 / HIPS Ply: 1 Job Number. N334496 Cust: R 8975 JRef:1X3G89750070 T21 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,RI01 / 1828/CAL114EBB ELEV.C/E DrwNo: 064.21.1307.55225 Truss Label: A9 SSB ! WHK 03/05/2021 6'3"4 12'0"1 19,101, 27'7"15 33'4"12 398" 6,3"4 5'8"12 T9"15 7915"1263"5 E5 5X5 III2X4 = 5X5 D E F 12 T 6 �2C4 i2G v `O W3 Z m B H A 1 a 3 �8'8" =4X6(A2) =5X5 =5X8 =5X5 =4X6(A2) 39'8" 10' 9'10" 9'10" 10, 1'. 10' 19'10., 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udell U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.206 E 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.385 E 999 240 B 1556 /- /- /947 l717 1284 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.066 J - - H 1556 /- /- /947 f717 P EDP: C Kzt: NA Des Ld: 37.00 HORZ(TL): 0.124 J Wind reactions based on MWFRS Mean Height: 15.00 ft NCBCLL: 10.00 Building Cade: Creep Factor: 2.0 B Br Width = 8.0 Min Re 1.8 9 q = TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.748 H Br Width = 8.0 Min Re = 1.8 g q Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.753 Bearings B & H are i rigid surface. Bearings B & H require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.999 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 2102 -2791 E - F 2189 -2492 C - D 1987 - 2524 F - G 1987 - 2524 Top chord: 2x4 SP #2 N; D - E 2189 -2492 G - H 2103 -2791 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Wind Chords Tens.Comp. Chords Tens. Comp. Wind loads based on MWFRS with additional C&C B - L 2434 -1769 K - J 2065 -1444 member design. L - K 2065 -1465 J - H 2434 -1748 Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. L - D 498 -118 K - F 539 - 531 D - K 539 - 531 F - J 498 -118 E - K 685 -462 *�iWtt�lljutjtyt • G r • w 0.708 i ,��� SAT 0 •� r �.�• .,�� mow` � ' 1 s � ' e1m"itA= 03/05/202 ) "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT•` FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing. , Refer to and follow the latest edition Component Safety Information, by TPI r of BCSI (Building and SBCA) safety practices prior to performing these functions. Installers shall provide temporary bracing BCSI. Unless noted otherwise, top chord shall have bottom have per properly attached structural sheathing and chord shall attached rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections a properly B3, B7 or 810 as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. t�efer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Building Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the ANMCOAWAW truss in with ANSI 1, or for handling, shipping,. bracing trusses. A this drawin conformance installation. and of seal on or cover pa a 6750 Forum Drive listing this drawing indicates acceptance of professional enc neering responsibility solely -for the design shown. The suitability and use of this Suite Fos -Designer drawing for any structure is the responsibility of the Building per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindusl .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249597 / HIPS Ply: 1 Job Number: N334496 Cust: R 8975 JRef:1X3G89750070 T5 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.53054 Truss Label: A10 SSB / WHK 03/05/2021 19' 28'8" 33'10"12 12 T 8, i 9'8" 5-2"12 59"4 OE5DX5 =5E5 �5F5 T3 12 T 6 T � 2X4 W ,2X4 G o C (a) (a) ri W3 B ID H 4X6(A2) =5X5 = SX8 = SX5 = 4X6(A2) 39'8" 1' 10' 9'10" 9'10" 10, 1' 10' 19,10'. 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.213 E 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.399 E 999 240 B 1556 /- /- /940 /718 /264 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.068 J - - H 1556 /- /- /940 /718 /- EXP: C Kzt: NA Des Ld: 37.00 (T ) L : 0.127 J HORZBuilding Wind reactions based on MWFRS NCBCLL: 10.00 Mean Height: 15.00 ft Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.934 H Brg Width = 8.0 Min Req = 1.8 Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.752 Bearings B & H are a rigid surface. Bearings B & li require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.751 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20 Lumber B - C 2194 - 2804 E - F 2386 - 2693 C - D 2057 - 2533 F - G 2066 - 2539 Top chord: 2x4 SP #2 N; T3 2x4 SP 2400f-2.OE; D - E 2502 -2773 G - H 2184 -2797 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) 1 X4 #3SRB or better continuous lateral restraint to B - L 2448 -1855 K - J 2163 -1578 be equally spaced. Attach with (2) 8d Box or Gun L - K 2147 -1575 J - H 2440 -1822 nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. Maximum Web Forces Per Ply (Ibs) (a) or scab reinforcement may be used in lieu of CLR Webs Tens.Comp. Webs Tens. Comp. restraint. substitute (1) scab for (1) CLR and (2) scabs L - D 470 -71 K - F 626 -612 for (2) CLR'S where shown. Scab reinforcement to be D - K 739 -778 F - J 466 -52 same size, species, grade, and 80% length of web µtnrmtrur//r/��r/rff E - K 789 -534 member. Attach with 0.128x3" gun nails @ 6" oc.NO `i, Wind � W ••S••./�`� '� Wind loads based on MWFRS with additional C&C `.���•�•••� member design. • •. y ��� •° Wind loading based on both gable and hip roof types. a 0. 708 1 s v s -o :• S Ai O Zko-.2.;�. ONA 10 COA � 03/05/2021 "WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition functions. of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper) attached structural sheathing and bottom chord shall have a properly attache U ri id ceilin Locations shown for permanent lateral restraint otwwebs shall have bracin installed per BCSI sections B3, B7 or B10 as applicable. Applgy plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW Buildin Components Group Inc. shall not,be responsible for any deviation from this drawing, any, failure to build the nNnwco vury A drawing truss in conformance with ANSI 1, or for handling, shipping,. installation and bracin4 of trusses. seal on this or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engtneenng responsibilityy solely -for the design shown. The suitability and use of4 is Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249598 / HIPS Ply: 1 Job Number: N334496 Cust: R 8975 JRef.,1X3G89750070 T4 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.54694 Truss Label: Al2 SSB / WHK 03/05/2021 9' 17' 30'8" + + + 91 8' 5'8" 8' 9' ,6X6 =5X5 =4X4 =6X6 C T2 D E T3 F 12 6 T T o (a) W (a) a W5 io �n I B G 1 A H gam-, 1 =4X6(A2) =6X6 =6X6 =6X6=4X6(A2) 39'8" 1' 10' 9'10" 10, 1' 10' 19,10" 29'8" 39'8" Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.251 J 999 360 Loc R+ ! R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.469 J 999 240 B 1556 /- /- /921 /720 /223 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.081 1 - - G 1556 /- /- /921 /720 /- EXP: C Kzt: NA HORZ TL : 0.150 1 Wind reactions based on MWFRS Des Ld: 37.00 ( ) NCBCLL: 10.00 Mean Height: 15.00 ft Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Reg = 1.8 TCDL: 4.2 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.939 G Brg Width = 8.0 Min Reg = 1.8 Soffit: 0.00 BCDL: 5.0 psf Bearings B & G are a rigid surface. Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.834 Bearings B & li require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.306 Members not listed have forces less than 375# Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCr: 0.18 Plate T e s : pi: yP () Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 IWAVE VIEW Ver: 20.02.00A.1020.20 B - C 2250 -2705 E - F 2239 -2478 Lumber C - D 2238 - 2478 F - G 2250 - 2704 Top chord: 2x4 SP #1; T2,T3 2x4 SP #2 N; D - E 2906 -3233 Bot chord: 2x4 SP #1; Webs: 2x4 SP #3; W2,W5 2x4 SP #2 N; Maximum Bot Chord Forces Per Ply (Ibs) Bracing Chords Tens.Comp. Chords Tens. Comp. (a) 1X4 #3SRB or better continuous lateral restraint to B - K 2330 -1856 J - 1 3176 - 2629 be equally spaced. Attach with (2) 8d Box or Gun K - J 3174 -2647 I - G 2329 -1835 nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. Maximum Web Forces Per Ply (Ibs) (a) or scab reinforcement may be used in lieu of CLR Webs Tens.Comp. Webs Tens. Comp. restraint. substitute (1) scab for (1) CLR and (2) scabs C - K 718 -428 E - 1 944 -834 for (2) CLR'S where shown. Scab reinforcement to be K - D 940 - 832 I - F 718 -430 same size, species, grade, and 80% length of web itaittfll>dlttt�t member. Attach with 0.128x3" gun nails @ 6" oc. 00 p<<�` , Wind i Wind loads based on MWFRS with additional C&C �' ��ew'•�'�'°'•'•'• �� ��.` +.• ' member design. �� •�\C! Wind loading based on both gable and hip roof types. _ �;• • s • ,a' • SAT O of COA gIONAI. gatt!/671t1�i41 03/05/2021 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing BCSI.. Unless noted otherwise, top chord shall have proper!v attached structural sheathing and bottom chord shall have a properly per attach6d rigid ceillnp Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10 as applicable. Apply plates to each face. of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positrons. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW BuildinccL�Components Group Inc. shall not,be responsible for any deviation from this drawing, any, failure to build the .—cc�+— bracing trusses; A this drawing truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation and of seal on or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibilit�yy solely'for the design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSIlTP1 1 Sec.2. For ,Wore information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindusl .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249610 / HIPS Ply: 1 Job Number: N334496 Cust: R 8975 JRef:1X3G89750070 T28 / FROM: LPM Qty: 1 7A5/320 ,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.55100 Truss Label: A14G SSB / WHK 03/05/2021 7' 13' 19' 28'4" 32'B" 39'8" 6' 6' 'i 9,4„ i 4,4„ i 7, �6X6 %6X6 =4X4 =8X10 =H1014 12 C D T2 E T3 F T4 G 6 T � T o (a) W (a) I B A H I l V. 1 5X5(A2) =H0510 =4X4 =6X8 III5X5K B3 -4X6 =3X6(A1) 28'4" i 11'4" 1010"4 5'1"12 1 4'4" 4'4" 7' 1' 18'10"4 I 24' 28'4" 32'8" i__all Loading Criteria (pst) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pt. NA Ce: NA VERT(LL): 0.179 D 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.338 D 999 240 B 1922 /_ /_ /- /884 /- BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.048 L - - K 4268 /- /- /- /1911 /- EXP: C Kzt: NA TL : 0.091 L - - Des Ld: 37HORZ.00 ( ) H 80 /- /- /- /60 /- Mean Height: 10.51 It NCBCLL: 0.00 Building Code: Creep Factor: 2.0 Wind reactions based on MWFRS TCDL: 4.2 sf Soffit: 0.00 p FBC 7th Ed. 2020 Res. Max TC CSI: 0.846 BCDL: 5.0 B Brg Width = 8.0 Min Req = 1.6 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.785 K Brg Width = 8.0 Min Req = 5.9 H Brg Width = 8.0 Min Req = 1.5 Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: No Max Web CSI: 0.819 Bearings B, K, & H are a rigid surface. Loc. from endwall: NA FT/RT:20(0)/10(0) Bearings B, K, & H require a seat plate. GCpi: 0.18 Plate Type(s): Members not listed have forces less than 375# Wind Duration: 1.60 WAVE HS VIEW Ver: 20.02.0OA.1020.20 Maximum Top Chord Forces Per Ply (Ibs) Lumber Chords Tens.Comp. Chords Tens. Comp. Top chord: 2x4 SP #2 N; T2,T3 2x6 SP #2 N; B - C 1596 - 3565 E - F 169 - 505 T4 2x6 SP SS; C - D 1465 -3467 F - G 400 -180 Bot chord: 2x4 SP 2400f-2.OE; B3 2x4 SP #2 N; D - E 1332 - 3056 G - H 538 -269 Webs: 2x4 SP #3; W6 2x4 SP #2 N; Bracing Maximum Bot Chord Forces Per Ply (Ibs) (a) 1X4 #3SRB or better continuous lateral restraint to Chords Tens.Comp. Chords Tens. Comp. be equally spaced. Attach with (2) 8d Box or Gun B - N 3126 -1377 L - K 786 -1874 nails(0.113"x2.5",min.). Restraint material to be supplied N - M 3815 -1821 K - J 786 -1874 and attached at both ends to a suitable support by M - L 2986 -1327 J - H 179 - 399 erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs Maximum Web Forces Per Ply (Ibs) for (2) CLR'S where shown. Scab reinforcement to be Webs Tens.Comp. Webs Tens. Comp. same size, species, grade, and 80% length of web 01101►111141rrrrrr Attach 0.128x3" 6" C - N 1089 -274 L - F 3047 -1224 member. with gun nails @ oc. `� H. ri ' N - D 440 -430 F - K 2007 -4053 Loading ••••,•e•F�' D - M 568 -883 F - J 1889 -778 M - E 834 - 67 G - J 344 - 528 #1 hip supports 7-0-0 jacks with no webs. �s �•• t � •••1..' E-L 1423 -3051 4y ,`C` Wind Wind loads and reactions based on MWFRS. 0.7QE ' /gyp a � I Wind loading based on both gable and hip roof types. s WARNING! This truss is not symmetric, but its exterior geometry makes erection error more S AT probable. It is imperative that this truss be installed ,00 ; Q properly. �� ep �� 1 A• �+` ne— NNA COA i � (3/05/2021 `"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! —IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building functions. Installers temporary Component Safety Information, by TPI an SBCA) for safety practices prior to performing these shall provide bracing per BCSI.. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall attached ri id ceilinct Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections have a properly B3, B7 or B10, as applicable. Apply plates to each face. of truss and position as shown above and on the Joini9Details, unless noted otherwise. Refer to drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. ALPINE Alpine, a division of ITW BuildingQ Components Group Inc. shall not be responsible for any deviation from this drawing, any. failure to build the mmvcowu truss in ANSIITPI 1, for handling, installation and bracing of trusses. A seal on this drawing or cover conformance with or shipping,. page 6750 Forum Drive listing this drawing indicates acceptance of professional en�Lineering responsibility solelyorthe design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the Building IJesigner ANSI/TPI 1 Sec.2. per Formore information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SECiN: 249599 / SPEC Ply: 1 Job Number: N334496 Cust: R 8975 JRef:1X3G89750070 T2 / FROM: RWM City: 1 7A5/320 ,182EC,E ,R101 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.55412 Truss Label: All SSB / WHK 03/05/2021 T zo l� 10'8" 11'3"15 16'0"1 23'7"15 297"15 39'8" 5'7"4 5'0"12 7' 15 4'82 7'7"14 6' 1010"1 5X5 5X5 =4X4 =5X5 =5X5 D E F G H 39'8" 9'101, + 91101. 10 1 19,10" 29'8" 39'8" TT to I I ev. Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.229 L 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.427 L 999 240 B 1556 /- /- 1932 1716 /257 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.076 K - - 1 1556 /- /- /930 1718 /- Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.142 K Wind reactions based on MWFRS NCBCLL: 00 Mean Height: 15.00 ItBuildin g Code: Creep Factor: 2.0 P B Brg Width = 8.0 Min Req = 1.8 Soffit: 0.00 0. TCDL: 4.2 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.820 1 Br Width = 8.0 Min Re = 1.8 g q Load Duration: 1.25 BCDL: 5.0 sf P MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.802 Bearings B & I are a rigid surface. Bearings B & I require a seat plate. Spacing: 24.0 " C&C Dist a: 3.97 ft Re Fac: Yes p Max Web CSI: 0.811 Members not listed have forces less than 375# Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0) Maximum Top Chord Forces Per Ply (Ibs) GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp. Wind Duration: 1.60 WAVE 18SS VIEW Ver: 20.02.00A.1020.20 B - C 2225 -2806 F - G 2509 -2878 Lumber C - D 2062 - 2521 G - H 2O44 - 2305 Top chord: 2x4 SP #2 N; T5 2x4 SP 2400f-2.OE; D - E 1917 -2214 H - 1 2093 -2649 Bot chord: 2x4 SP #1; E - F 1976 -2258 Webs: 2x4 SP #3; Wind Maximum Bot Chord Forces Per Ply (Ibs) Wind loads based on MWFRS with additional C&C Chords Tens.Comp. Chords Tens. Comp. member design. B - M 2452 -1880 L - K 2805 - 2204 Wind loading based on both gable and hip roof types. M - L 2814 -2230 K - 1 2266 -1674 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. M - D 1699 -1345 G - K 774 - 669 M - E 760 - 872 K - H 693 - 431 ,.,1d11t�Itrlltq�rue,._ M - F 856 -742 lAloine. a COA #0%W, , w y 1A1- Nrh�untnuu�p 03/05/2021 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS quire extreme care in fabricating, handling,shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building t Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary r BCSI. Unless noted otherwise, top chord shall have proper) attached structural sheathing and bottom chord. shall have a properly iid ceiling Locations shown for permanent lateral restraint o�webs shall have bracin installed p r BCSI s coons B3, B7 or B10. e. AppTy plates to each face. of truss and position as shown above and on the Join, Details, un�ess notedPotherwise. Refer to 6OA-Z for standard plate positions. Refer to jobs General Notes page for additional information. ivision of ITW Buildingq�Components Group Inc. shall not be respponsible for any deviation from this drawing, any, failure to build the ,form with ANSI PI 1, or for handling, shipping,, installation. and bracin4 of trusses. A seal on this drawrnq or cover page drawing indicates acceptance of professional engineering responsibility solely -for the design shown. The suitability and use of this lrawing for any structure is the responsibility of the Building Designer per ANSI/TP1 1 Sec.2. :or more information see these web sites: Alpine: alpineitw.com; TPI: (pinst.org; SBCA: sbcindustry.com; ICC: iccsafe.org; AWC: awc.org AL NE ANMCCWV 6750 Forum Drive Suite 305 Orlando FL, 32821 • SEQN: 249600 / COMN Ply: 1 Job Number: N334496 Cust: R 8975 JRef:1X3G89750070 T20 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.54553 Truss Label: A13 SSB ! WHK 03/05/2021 5'7"4 10'8" + 13'3"1r5 217'15 + 317'15 + 39'8" 5'7"4 5'0"12 2-7"1 8'4" 10, 8101 =5X5 D 12 =5X5 T3 =_H0610 T4 —6G T 6E2X4 T C (a) W B H A 11 8,8„ 3X6(A1) B1 -3X8 =5X5 N =4X6 =5X5=3X6(A7) 20'8" 5181. 13'4" 1 OT" 10'8" Loading Criteria (psi) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 it NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; T3 2x4 SP #1; T4 2x4 SP 2400f-2.OE; Bot chord: 2x4 SP #2 N; 131 2x4 SP #1; Webs: 2x4 SP #3; W7 2x4 SP #2 N; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. 5'4" T 10" 7' 10" 16' 23'10" 31'8" 8' 1' 39'8"+ Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs), or'=PLF Pg: NA Ct: NA CAT: NA PP Deflection in loc Lldefl L!# Gravity Non -Gravity Pf: NA Ce: NA VERT(LL): 0.043 M 999 360 Loc R+ / R- / Rh / Rw / U / RL Lu: NA Cs: NA VERT(CL): 0.080 M 999 240 B 840 1- 1- /551 /397 /257 Snow Duration: NA HORZ(LL): 0.017 J - - N• 315 /- /- /159 /140 /- HORZ(TL): 0.028 J H 585 /- /- /436 /242 /- Building Code: Creep Factor: 2.0 Wind reactions based on MWFRS FBC 7th Ed. 2020 Res. Max TC CSI: 0.957 B Brg Width = 8.0 Min Req = 1.5 TPI Std: 2014 Max BC CSI: 0.647 N Brg Width = 68.0 Min Req = - Rep Fac: Yes Max Web CSI: 0.546 H Brg Width = 8.0 Min Req = 1.5 Bearings B, N, & H are a rigid surface. FTlRT:20(0)!10(0) Bearings B, N, & H require a seat plate. Plate Type(s): I Members not listed have forces less than 375# WAVE HS VIEW Ver: 20.02.00A.1020.20 Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 959 -1265 E - F 645 - 628 C - D 755 -932 F - G 648 -471 D-E 808 -911 G-H 324 -611 03/05/2021 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - M 1088 - 733 K - J 924 - 213 M - L 931 - 620 J - H 455 -107 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp C - M 396 - 367 L - F 903 - 565 D - M 619 - 454 F - K 1390 -1254 M - E 442 - 299 K - G 854 -1043 E - L 449 - 564 **WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chard shall have a properly attached r'iiid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face. of truss and position as shown above and on the Join Details, unless noted otherwise. Ffefer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANMCCNmnuv truss in conformance with ANSIITPI 1, or for handling, shipping,, installation. and bracingof trusses. A seal on this drawingg or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional en sneering responsibility solelyorthe design shown. The suitabilip, and use of this Suite 305 drawing for any s9r'ucture is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindusl .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 4 SEQN: 249601 / COMN Ply: 1 Job Number: N334496 Cust*R 8975 JRef:1X3G89750070 T19 / FROM: RWM Qty: 1 7A5/320 ,182EC,E ,RI01 / 1828/CALI14EBB ELEV.C/E DrwNo: 064.21.1307.55678 Truss Label: A15 SSB / WHK 03/05/2021 5'74 10'8" 15'3"15 23'3"15 31'8"1 32'8" 39,8" r 5,74 'f' 5'0'12 'i' 4'7"15 i' 8' '+ 8'4"2 +11 '15 7' T ,2 6 2X4 C En B � A 5X08 5X5 D = 5X14 = H0510 = 5X10(SRS) T E T3 F T4 G (a) o Tm io J 111�6,8., N I—IM L K 1 =_3X6(A1) =5X5 =4X6 =4X4 =5X5 21' 5' 13'8" 5' 5' 518" 8' 1' 26' 31'8" 39'8" Loading Criteria (psf) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II Des Ld: 37.00 EXP: C Kzt: NA Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.97 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; T3,T4 2x4 SP #1; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Bracing (a) 1X4 #3SRB or better continuous lateral restraint to be equally spaced. Attach with (2) 8d Box or Gun nails(0.113"x2.5",min.). Restraint material to be supplied and attached at both ends to a suitable support by erection contractor. (a) or scab reinforcement may be used in lieu of CLR restraint. substitute (1) scab for (1) CLR and (2) scabs for (2) CLR'S where shown. Scab reinforcement to be same size, species, grade, and 80% length of web member. Attach with 0.128x3" gun nails @ 6" oc. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U# Gravity Non -Gravity Pf: NA Ce: NA VERT(LL): 0.038 O 999 360 Loc R+ / R- / Rh / Rw / U / RL Lu: NA Cs: NA VERT(CL): 0.072 O 999 240 B 745 /- /- /497 /341 /276 Snow Duration: NA HORZ(LL): 0.017 K - - M 1429 P /- /726 /654 /- HORZ(TL): 0.031 K - - L 629 P P /238 /218 /- Building Code: Creep Factor: 2.0 1 534 /- /- /399 /245 /- FBC 7th Ed. 2020 Res. Max TC CSI: 0.701 Wind reactions based on MWFRS TPI Std: 2014 Max BC CSI: 0.635 B Brg Width = 8.0 Min Req = 1.5 Rep Fac: Yes Max Web CSI: 0.703 M Brg Width = 8.0 Min Req = 2.0 L Brg Width = 8.0 Min Req = 1.5 FT/RT:20(0)/10(0) I Brg Width = 8.0 Min Req = 1.5 Plate Type(s): Bearings B, M, L, & I are a rigid surface. WAVE HS VIEW Ver: 20.02.00A.1020.20 Bearings B, M, L, & I require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. B - C 1109 -1100 E - F 800 - 732 C - D 1003 - 901 G - H 766 - 618 D - E 835 - 674 H - I 595 - 577 as��`�};••�-AGE S�: ,.•� i • e i o. i08 1 • jo•. ,.,•�, COAW lot, �t ryq�ONAi. 03/05/2021 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp B - O 936 - 827 M - L 464 - 410 O - N 570 - 442 L - K 530 - 367 N - M 598 - 426 K - 1 451 - 326 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Comp. C - O 502 -291 M - F 909 -732 O - D 469 - 387 L - G 947 - 898 E - M 1635 -1574 "'WARNING' READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per SCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached r'Ipid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face. oT truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildingqComponents Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANMCOMPAW truss in conformance with ANSI 1, or for handling, shipping,, Installation. and bracingof trusses. A seal on this draw(nq or cover pa qa 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibili��r solelyor the design shown. The suitability and use of th!s Suite Fos drawing for any structure is the responsibility of the Building -Designer per ANSI/TP1 1 Sec.2. For.more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 2496021 SPEC Ply: 1 Job Number. N334496 Cusl: R 8975 JRef1X3G89750070 T18 / FROM: RWM Qty: 1 ,7A5/320 ,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.53506 Truss Label: A16 �SSB / WHK 03/05/2021 5'74 10'8" 17'3"15 23'6" 29'8"l 32'8" 39'8" 5'74 5'11A2 6'7"15 6'2"1 6'2"1 2'11"1 7' 19'3"15 5p5 T6 � —12 SLS �n C =8X8 -8X8 :5X10(SRS T � ao E F G H I J K n o T Zp B Z AB AE Ms� A N la I�e'e" 3X6(A1) =5X5 =5X5 W V =4X6 T 1112X4 ") R Q P =5XQ5 =3X6(A1) 1 21' 5' 13'8" 8' 1'3"15 5' 3 ' 8' 8' 16' 17' "15 26' 29'6"5 39'8" i 3T'i i 2'111 r 2 3 8; Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs) TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc L/defl L/# Gravity Non -Gravity TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.037 Y 999 360 Loc R+ / R- / Rh / Rw / U / RL BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.069 Y 999 240 B 774 /- P /508 /355 /317 BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.016 0 - - U 1323 P P /633 /586 /- Des Ld: 37.00 EXP: C Kzt: NA HORZ(TL): 0.030 0 R 711 /- /- /257 /237 /- NCBCLL: 10.00 Mean Height: 15.00 ft Building Code: Creep Factor: 2.0 M 531 P P /381 /247 P Soffit: 0.00 TCDL: 4.2 psf BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.948 Wind reactions based on MWFRS Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.636 B Brg Width = 8.0 Min Req = 1.5 U Brg Width = 8.0 Min Req = 1.8 Spacing: 24.0 " C&C Dist a: 3.97 ft Rep Fac: Yes Max Web CSI: 0.584 R Brg Width = 8.0 Min Req = 1.5 Loc. from endwall: Any FT/RT:20(0)/10(0) M Brg Width = 8.0 Min Req = 1.5 GCpi: 0.18 Plate Type(s): Bearings B, U, R, & M are a rigid surface. Wind Duration: 1.60 WAVE VIEW Ver: 20.02.o0A.1020.20 Bearings B, U, R, & M require a seat plate. Lumber Members not listed have forces less than 375# Top chord: 2x4 SP #2 N; Maximum Top Chord Forces Per Ply (Ibs) Bot chord: 2x4 SP #2 N; Chords Tens.Comp. Chords Tens. Comp. Webs: 2x4 SP #3; B - C 1118 -1151 F - G 823 -776 Plating Notes C - D 1027 -960 G - H 834 -791 D - E 791 - 722 K - L 681 - 548 All plates are 2X4 except as noted. E - F 823 -777 L - M 628 - 571 (") 1 plate(s) require special positioning. Refer to scaled plate plot details for special positioning Maximum Bot Chord Forces Per Ply (Ibs) requirements. Chords Tens.Comp. Chords Tens. Comp. Wind B-Y 978 -830 T-S 585 -491 Wind loads based on MWFRS with additional C&C Y - X 627 -411 S - R 584 -491 member design. X - W 462 -350 R - Q 424 - 356 Wind loading based on both gable and hip roof types. tiStittltr111A1trr11 W - V 462 -350 Q - P 424 -355 U - T 589 - 490 O - M 445 - 354 v �,v ��`� •� �'r Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. Webs Tens. Camp. � o s 0.70$ 1 C-Y 445 -257 U-AB 611 -605 D 453 - 285 AB- H 504 - 522 s E - Z 1516 -1447 R -AE 930 - 847 i T = Z - U 1536 -1466 AE- K 910 - 826 . � �t • jf ........... •• COA f�l /QfVrAL 03/05/2021 "'WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing.. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have �roper)v attached structural sheathing and bottom chord shall have a properly attached rigpid ceiling Locations shown for permanent lateral restraint of webs shall have bracln installed per BCSI sections B3, B7 or B10, as appllcab-le. Apply plates to each face of truss and position as shown above and on the Jointi9Deta1ls, unless noted otherwise. Pefer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinggComponents Group Inc. shall not. be responsible for any deviation from this drawing, any. failure to build the •vrrH,COW— truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation and bracing of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional encLmeering responsibilittyy solely for the design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For•more information see these web sites: Alpine: alpineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249603 / GABL Ply: 1 Job Number: N334496 Cust: R 8975 MetlX3G89750070 T3 / FROM: HMT Qty: 1 7A5/320 ,182EC,E ,R101 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.53600 Truss Label: B1GE SSB / WHK 03/05/2021 1018" 21'4" - 10,8.' 10'8" _ � 4,8„ 1 2' � (TYP) =-4F4 Loading Criteria (psi) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A16015ENC160118 & GBLLETIN0118 for gable wind bracing and other requirements. =b715 21'4" 21'4" 21,4" Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf. NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/l 0(0) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.004 R 999 360 VERT(CL): 0.007 R 999 240 HORZ(LL): 0.005 L - - HORZ(TL): 0.006 L - - Creep Factor: 2.0 Max TC CSI: 0.196 Max BC CSI: 0.164 Max Web CSI: 0.069 03/05/2021 Ver: 20.02.00A.1020.20 ♦ Maximum Reactions (lbs), or *=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 245 /- /- /134 /103 /243 J* 72 A /- /35 /33 A Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 J Brg Width = 248 Min Req = - Bearings B & B are a rigid surface. Bearings B & B require a seat plate. Members not listed have forces less than 375# **WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, Installingi and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performng these functions. Installers shall provide temporary rwi bracing per BCSL Unless noted othesetop chord shall have proper)v attached structural sheathing and bottom chord shall have a properly attachetl rigid ceiling Locations shown for'permanent lateral restraint of webs sha!1 have bracin installed per BCSI sections B3, B7 or 1310, as applrcab4e. Apply places to each faceoT truss and position as shown above and on the Joinetails, unless noted otherwise. Defer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildincL Components Group Inc. shall not be responsible for any deviation from this drawing, any, failure to build the ANMCOWAW truss in conformance with ANSIfTPI 1, or for handling, shipping,, installation and bracing of trusses. A seal on this drawinq or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibili(t�� solely -for the design shown. The suitability and use of ih!s Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSVVT l 1 Sec.2. For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC:awc.org Odando FL, 32821 SEQN: 249604 / GABL Ply: 1 Job Number: N334496 Cust: R 8975 JRef:1X3G89750070 T1 / FROM: RWM Qty: 1 ,7A5/320 ,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.54397 Truss Label: C1GE �SSB / WHK 03/05/2021 i Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 It Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Webs: 2x4 SP #3; Plating Notes All plates are 2X4 except as noted. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes See DWGS A16015ENC160118 & GBLLETIN0118 for gable wind bracing and other requirements. 7' 7' 7' 5, '1 2' —' (TYP) 4X4 D 14' 14' 3w Criteria (Pg,Pf in PSF) NA Ct: NA CAT: NA NA Ce: NA NA Cs: NA )w Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.005 J 999 360 VERT(CL): 0.008 J 999 240 HORZ(LL): 0.004 H - - HORZ(TL): 0.006 J Creep Factor: 2.0 Max TC CSI: 0.308 Max BC CSI: 0.177 Max Web CSI: 0.142 Ver: 20.02.00A.1020.20 ,o70I1 Ell 49 COA ffft,$V0NAL V ,�,l 03/05/2021 ♦ Maximum Reactions (Ibs), or'=PLF Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B' 68 /- /- /38 /30 /13 F 268 /- A /206 1134 /- Wind reactions based on MWFRS B Brg Width = 159 Min Req = - F Brg Width = 8.0 Min Req = 1.5 Bearings B & F are a rigid surface. Bearings B & F require a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. Chords Tens. Comp. C - D 377 -129 D - E 376 -129 Maximum Gable Forces Per Ply (Ibs) Gables Tens.Comp. Gables Tens. Comp. C - J 511 - 238 H - E 511 - 238 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handling shipping, installing and bracing.. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper) attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint o>Ywebs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Buildin$Components Group Inc. shall not,be responsible for any deviation from this drawing, any failure to build the pNmvcopvpry truss in conformance with ANSIII PI 1, or for handling, shipping,, installation and bracing of trusses. A seal on this drawing or cover pa 9a 6750 Forum Drive listing this drawing indicates acceptance of professional enpineermg responsibilityy solely -for the design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Formore information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 249616 / EJAC Ply: 1 Job Nuber: N334496 Cust: R 8975 JRef:1X3G89750070 T15 / FROM: RWM Qty: 14 ,7A55 30m, 182EC,E ,RI01 / 1828/CALIMEBB ELEV.C/E DrwNo: 064.21.1307.54350 Truss Label: EJ7 SSB / WHK 03/05/2021 w Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " C 12'2"11 12 6 M O u7 V B .�' A D 1 7- 7- Wind Criteria Snow Criteria (Pg,Pf in PSF) Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA Speed: 160 mph Pf: NA Ce: NA Enclosure: Closed Lu: NA Cs: NA Risk Category: II Snow Duration: NA EXP: C Kzt: NA Mean Height: 15.00 ft Building Code: TCDL: 4.2 psf BCDL: 5.0 psf FBC 7th Ed. 2020 Res. MWFRS Parallel Dist: h/2 to h TPI Std: 2014 C&C Dist a: 3.00 ft Rep Fac: Yes Loc. from endwall: not in 4.50 It FT/RT20(0)/l0(0) GCpi: 0.18 Plate Type(s): Wind Duration: 1.60 inrevr: Lumber Top chord: 2x4 SP #1; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.015 D HORZ(TL): 0.028 D Creep Factor: 2.0 Max TC CSI: 0.720 Max BC CSI: 0.507 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 ,%*�._ H. N GE o. 7+08 1 o r+� v •• c coA fft z 8/OOVA L Vl V 03/05/2021 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 331 /- /- /249 /108 /208 D 125 /- /- 173 /- /- C 174 /- /- /128 /169 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Big Width = 1.5 Min Req = - C Big Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT'* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI an � SBCA) fo'r satPety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicab-le. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Defer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW BuildinccLL Components Group Inc. shall not.be responsible for any deviation from this drawing, any failure to build the AN-CO-W truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracingp� of trusses; A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibilityy solely for the design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For.more information see these web sites: Alpine: al ineitw.com; TPI: t insl.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 2496061 JACK Ply: 1 Job Number: N334496 Cust: R 8975 JRef:1X3G89750070 T11 / FROM: LPM Qty: 4 ,7A5/320 ,182EC,E ,Riot / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.54695 Truss Label: CJ5 KD / YK 03/05/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " C 11'2"5 12 6 M N Cl) M B A 8'8" D Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 It TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord. 411 "4 4' 11 "4 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.005 D HORZ(TL): 0.010 D Creep Factor: 2.0 Max TC CSI: 0.549 Max BC CSI: 0.257 Max Web CSI: 0.000 EW Ver: 20.02.00A.1020.20 o +i 0.708 SAT • COA NAL mi"Mig 03/05/2021 �•._ 1, 1 ♦ Maximum Reactions (lbs) Gravity Non -Gravity Loc R+ /R- /Rh /Rw /U /RL B 256 /- /- /200 /88 /152 D 89 !- /- /51 /- /- C 118 /- /- /85 /116 A Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT"" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord. shall have a properly attachetl ri id ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. App�y plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall notbe responsible for any deviation from this drawing, any failure to build the ANCO A- truss in conformance with ANSIII PI 1, or for handling, shipping,, installation n and bracin of trusses: A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engiineering responsibilittyy solely or the design shown. The suitability and use of This Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSIrr 11 Sec.2. For more information see these web sites: Alpine: aI ineitw.com: TPI: t inst.or ; SBCA: sbcindust .com; [CC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 2496071 JACK Ply: 1 Job Number: N334496 Cust: R 8975 JRef1X3G89750070 T26 / FROM: LPM Qty: 4 ,7A5/320 ,182EC,E ,R101 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.54303 Truss Label: CJ3 �SSB / WHK 03/05/2021 Loading Criteria (psi) Wind Criteria TCLL: 20.00 Wind Std: ASCE 7-16 TCDL: 7.00 Speed: 160 mph BCLL: 0.00 Enclosure: Closed BCDL: 10.00 Risk Category: II EXP: C Kzt: NA Des Ld: 37.00 Mean Height: 15.00 ft NCBCLL: 10.00 TCDL: 4.2 psf Soffit: 0.00 BCDL: 5.0 psf Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 Spacing: 24.0 " C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131"x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 2' 11 "4 2' 11 "4 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): C T Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.001 D HORZ(TL): 0.001 D Creep Factor: 2.0 Max TC CSI: 0.234 Max BC CSI: 0.105 Max Web CSI: 0.000 Ver: 20.02.00A.1020.20 Y. • • i o. 708 1 ,4 SAT O Coo, 03/05/2021 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS the latest edition of BCSI (Building Installers shall provide temporary bottom chord shall have a properly )er BCSI sections B3, B7 or B10, iless noted otherwise. Refer to Alpine, a division of truss in conformanc listing this drawin drawing for any siru For more information TPI: tpinst.org; SBCA: 10'2"5 rn i� CV 8'8" ♦ Maximum Reactions (lbs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 185 A /- /156 /71 /99 D 50 /- /- 127 A /- C 63 /- /- /44 /64 /- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# deviation from this drawing, any, failure to build the of trusses; A seal on this drawing or cover page or the design shown. The suitability and use Nis ALPINE A-COW- 6750 Forum Drive Suite 305 Orlando FL, 32821 SEQN: 2496081 JACK I Ply: 1 Job Number: N334496 Cust: R 8975 JRefAX3G89750070 T27 / : 4 , FROM: LPM QtyA5/320 ,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.55693 Truss Label: CA KD / WHK 03/05/2021 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " 12 6 [::�7- C 43 V Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Lumber Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP #2 N; Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes Provide (2) 0.131 "x3.0", min. toe -nails at top chord. Provide (2) 0.131"x3.0", min. toe -nails at bottom chord. 1,Ea .11"4 11114 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:20(0)/10(0) Plate Type(s): RAN 00 M 1 Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.000 D HORZ(TL): 0.000 D Creep Factor: 2.0 Max TC CSI: 0.183 Max BC CSI: 0.022 Max Web CSI: 0.000 VIEW Ver: 20.02.00A.1020.20 cif �i 4. 708 1 % SAT O COA t aNAl. E ,N�• 03/05/2021 9'2"5 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ / R- / Rh / Rw / U / RL B 143 /- /- /145 /76 /45 D 11 /-2 /- /14 /10 /- C - /-15 /- /29 /33 1- Wind reactions based on MWFRS B Brg Width = 8.0 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, as applicable. Apply ptates to each face of truss and positron as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANMCOWAW truss in conformance with ANSI/TPI 1, or for handling, shipping,installation and bracing of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawing indicates acceptance of professional engineering responsibilitty� solely for the design shown. The suitability and use of this Suite 305 drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. For,more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821 SEQN: 2496091 HIP_ Ply: 1 Job Number: N334496 Cust: R 8975 JRef:1=389750070 T16 / FROM: HMT Qty: 2 7A5/320 ,182EC,E ,RI01 / 1828/CALI/4EBB ELEV.C/E DrwNo: 064.21.1307.53850 Truss Label: HJ7 KD / WHK 03/05/2021 Ae, 5'3"5 9110"1 5'3"5 4'6"11 n 127'3 12 4.24 2X4 C v m n v B T a; a 8'8" A FE 2X4(A1) =4X4 Loading Criteria (psf) TCLL: 20.00 TCDL: 7.00 BCLL: 0.00 BCDL: 10.00 Des Ld: 37.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.25 Soacina: 24.0 " Lumber 1'5" 9'2"2 1 7„14 97"2 9'10'1 Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: C Kzt: NA Mean Height: 15.00 ft TCDL: 4.2 psf BCDL: 5.0 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 It Loc. from endwall: NA GCpi: 0.18 Wind Duration: 1.60 Top chord: 2x4 SP #2 N; Bot chord: 2x4 SP 2400f-2.0E; Webs: 2x4 SP #3; Loading Hipjack supports 6-11-8 setback jacks with no webs. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. (3) 16d common (0.162"x3.5") nails at top chord (3) 16d common (0. 1 62"x3.5") nails at bottom chord Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:20(0)/l 0(0) Plate Type(s): Defl/CSI Criteria PP Deflection in loc Udefl U# VERT(LL): 0.040 F 999 360 VERT(CL): 0.076 F 999 240 HORZ(LL): 0.010 C - - HORZ(TL): 0.018 C Creep Factor: 2.0 Max TC CSI: 0.546 Max BC CSI: 0.416 Max Web CSI: 0.260 03/05/2021 Ve r: 20.02.00A.1020.20 ♦ Maximum Reactions (Ibs) Gravity Non -Gravity Loc R+ /R- !Rh /Rw /U /RL B 326 /- /- /- /154 /- E 364 /- /0 !- /84 /0 D 214 /- /- /- /177 P Wind reactions based on MWFRS B Brg Width = 10.6 Min Req = 1.5 E Brg Width = 1.5 Min Req = - D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Members not listed have forces less than 375# Maximum Top Chord Forces Per Ply (Ibs) Chords Tens.Comp. B - C 394 - 562 Maximum Bot Chord Forces Per Ply (Ibs) Chords Tens.Comp. B - F 531 - 358 Maximum Web Forces Per Ply (Ibs) Webs Tens.Comp. C - F 394 - 583 "WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING! "IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS Trusses require extreme care in fabricating, handiin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly attached ri td ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, as applicable. Apply lates to each face otruss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information. Alpine, a division of ITW Building Components Group Inc. shall not be restonsible for any deviation from this drawing, any, failure to build the ANMCOWANV truss in conformance with ANSI/TPI 1, or for handling, shipping,, installs ion and bracing of trusses. A seal on this drawing or cover page 6750 Forum Drive listing this drawin indicates acceptance of professional en sneering responsibili(t�� solely -for the design shown. The suitability and use of this Suite 305 drawing for any sfIucture is the responsibility of the BuildingUesigner per ANSI/TPI 1 Sec.2. Fopmore information see these web sites: Aloine: aloineilw.com: TPI: toinsl.ora: SBCA: sbcindustrv.com: ICC: iccsafe.ora: AWC: awc.ora Oriando FL, 32821 Gable Stud Reinf orcerlent Detail ASCE 7-161 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1'00 Or, 140 mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1,00 Or, 140 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00 Or' 120 moh Wind Soeed. 15' Mean Heloht, Partially Enclosed, Exoosure D. Kzt = 1,00 S 2x4 Brace Gable Vertical Spacing Species Grade No Braces (1) Ix4 'L' Brace 1( (1) 2x4 'L' Brace x (2) 2x4 'L' Brace xx (1) 2x6 'L' Brace x (2) 2x6 'L' Brace x Group A Group B Group A Group B Group A Group B Group A Group B Group A Group B p #1 / #2 3' 10' 6' 7' 6' 10' 7' 9' 8' 1' 9' 3' 9' 7' 12' 2' 12' 8' 14' 0' 14' 0' U S I F #3 3' 8' 5' 9' 6' 2' 7' 6' 7' 11' 9' 1' 9' 6' 12' 0' 12' 6' 14' 0' 14' 0' Stud 3' 8' 5' 9' 6' 1'1 7' 8' 7' 11' 9' 1' 9' 6' 12' 0' 12' 6' 14' 0' 14' 0' Q HF Standard 11,11 0j 4' 0' 6' 8' 6' 1' 7' 0' 8' 2' 9' 4' 9' 8' 12' 4' 12' 9' 14' 0' 14' 0' -j S P #2 3' 10' 6' 7' 6' 10, 7' 9' B' 1' 9' 3' 9' 7' 12' 2' 12' 8' 14' 0' 14' 0' #3 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, 11' 11' 8' 14' 0' 14' 0' d P Stud 3' 9' 5' 3' 5' 7' 6' 11' 7' 5' 9' 2' 9' 7' 10, 11' 11' 8' 14' 0' 14' 0' Standard 3' 6' 4' 7' 4' 11' 6' 2' 6' 7' 8' 4' 8' 11' 9' 8' 10' 4' 13' 1' 14' 0' U_ #1 / #2 4' 5' 7' 6' 7' 9' 8' 10, 9' 3' 10' 7' ill 0' 13' 11' 14' 0' 14' 0' 14' 0' _ S P rr #3 4' 2' 7' 1' 7' 9' 8' 9' 9' 1' 10' 5' 10, 10, 13' 9' 14' 0' 14' 0' 14' 0' <J l' Stud 4' 2' 7' 1' 7' 6' 8' 9' 9' 1' 10' 5' 10' 10' 13, 9' 14' 0' 14' 0' 14' 0' O r Standard 4' 2' 6' 1' 6' S' 8' 1' 8' 8' 10, 5' 10, 10, 12, 8' 13' 7' 14' 0' 14' 0' CU CU S P #1 4' 7' 7' 7' 7' 11' 9' 0' 9' 4' 10, 8' Ill 1' 14' 0' 14' 0' 14' 0' 14' 0' #2 4' 5' 7' 6' 7' 9' 8' 10, 9' 3' 10' 7' 11' 0' 13' 11' 14' 0' 14' 0' 14' 0' #3 4' 4' 6' 5' 6' 10, 8' 6' 9' 1' 10' 6' 10, 11' 13' 4' 14' 0' 14' 0' 14' 0' QJ r D r L Stud 4' 4' 6' S' 6' 10, 8' 6' 9' 1' 10, 6' 10, 11' 13' 4' 14' 0' 14' 0' 14' 0' Standard 4' 2' 5' 8' 6' 0' 7' 6' 8' 0' 10, 2' 10, 10' 11' 10, 12' 7' 14' 0' 14' 0' #Ear 4' 10' 8' 3' 8' 7' 9' 9' 10' 2' 10' 7' 12' 1' 14' 0' 14' 0' 14' 0' 14' 0' d S P P 4' 7' B' 2' 8' S' 9' 8' 10, 0' 11' 6' 12, 0' 14' 0' 14' 0' 14' 0' 14' 0' LJ <J l I C 4' 7' 8' 2' 8' 5' 9' 8' 10, 0' 11' 6' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' O I l r St 4' 7' 7' 0' 7' 5' 9' 4' 10, 0' 11' 6' 12, 0' 14' 0' 14' 0' 14' 0' 14' 0' X 5' 1' 8' 5' 8' 8' 9' 11' 10' 3' 11' 9' 12' 3' 14' 0' 14' 0' 14' 0' 14' 0' d S P #2 4' 10' 8' 3' 8' 7' 9' 9' 10' 2' 11' 7' 12' 1' 14' 0 14' 0' 14' 0' 14' 0' #3 1 4' 9' 7' 4' 7' 10' 9' 8' 10' 1' 11' 7' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' 757 --I r D r L Stud 4' 9' 7' 4' 7' 10' 9' 8' 10' 1' 11' 7' 12' 0' 14' 0' 14' 0' 14' 0' 14' 0' Standard 4' 7' 6' 6' 6' 11' 8' 8' 9' 3' 11' 6' 12' 0' 13' 7' 14' 0' 14' 0' 14' 0' Diagonal brace option' vertical length may be doubled when diagonal brace Is used, Connect diagonal brace for 600# at each end, Max web total length Is 14', Vertical length shown In table above, Connect diagonal at mldooint of vertical web. AN ITW CO 11 514% Earth% City\ Expressway \ \ suite\ 242 \ \ Earth\ City,\ MO\ 63045 aymm About 18' L 'L' Brace End Zones, typ. 2x6 DF-L #2 or better diagonal I T brace) single 8, or double cut L (as shown) at upper end, 14141-1 Refer to chart a ■■VARNwGn■ READ AND FmLDV ALL NOTES ON THIS DRAVIMCd -DIPORTANTxx FURNISH THIS DRAVMG TO ALL CONTRACTORS INCLUBTHE DUTALLERSc UROIG Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refe allow the infest edition of HCSI (BuRding Component Safety Information, by TPI nod SHCA) fo •nctices prior to performing these functlons. Installers shall provide tenpornry braGng pe 'less noted otherwise, top chord shall have properly attached structural sheathing and bo 'all have a properly attached rigid ceiling. Locations shown for permanent lateral restraint 'all have brocing Installed per SCSI sections B3, B7 or B10, as applicable. Apply plates to ead ' truss and position as shown above and on the Joint Details, unless noted otherwise. ,fer to drawings 160A-Z for standard plate positions. Alpine, a division of ITV Building Components Group Inc shall not be responsible for any devla+ Is drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shll -tatlatton & bracing of trusses. A seal on this drawing or cover page listing this drawing, Indicates acceptance of professlonc gineeNng responsanlllty solely for the design shown. The sultab" and use of this drawing r any structure is the responstbMty of the MdIng Designer per ANSI/TPI 1 Sec:Z For more Information see this Job's general notes page and these web sites' ALPINE' www.alpineitw,coni TPL ow,tpinstorgi SBCA' wrw,sbcindustry.orgi ICC' wwwlccsafearl BCSL S Bracing Group Species and Grades, Group At S ruce-Pine-Fir Hen -Fir #1 / #2 IStandarq #2 Stud #3 Stud #3 IStandardl Dou ins Flr-Larch Southern Plnexxx #3 #3 Stud Stud Standard Standard Group Bt Hem -Fir #1 & Btr #1 Dou Ins Fir -Larch Southern Plnexxx #1 #1 #2 #2 Ix4 Braces shot( be SRB (Stress -Rated Board). xwFor Ix4 So. Pine use only Industrial 55 or Industrial 45 Stress -Rated Boards, Group B values may be used with these rades, Goble Truss Detail Notes, Wind Load deflection criterion Is L/240. Provide uplift connections for 75 plf over, continuous bearing <5 psf TC Dead Load), Gable end supports load from 4' 0' outlookers with 2' 0' overhang, or 12' plywood overhang, Attach 'L' braces with 10d (0.128'x3.0' min) nails, )K For <1) 'L' brace, space nails at 2' o.c, In 18' end zones and 4' o.c. between zones. )KFor (2) 'L' braces' space nails at 3' o,c. In IS' end zones and 6' o,c. between zones. 'L' bracing must be a minimum of 80X of web member length. Gable Vertical Plate Sizes 11 411tf/{ to,,,, Vertical Len th No Splice Less than 4' 0' 2X3 Greater than 4' 0', but less than 11' 6' 3X4 Greater than 11' 6' 4X4 9 �f/ice + Refer to common truss design for •a. peak, splice, and heel plates, +� Refer to the Building Designer for conditions lx abl ve t1X1 le` th, not addressed by this detail, 3' REF- ASCE7-16-GAB16015 DATE 01/26/2018 AT' 0 •� DRWG A16015ENC160118 MAX, T❑T, LD, 60 PSF 05/202 l n MAX, SPACING 24,0' 'T Relnfoi Memb Gn Tr Gabe Detail F'nr I Pt -in VPrtlrnl Gable Truss Plate Sizes ppropriate Alpine gable detail for e sizes for vertical studs. Engineered truss design for peak, b, and heel plates, vertical plates overlap, use a .te that covers the total area of lapped plates to span the web. 2*2X4 2X8 Nrovide connections for uplift specified on the engineered truss design, Attach each 'T' reinforcing member with End Driven Nnllsl 10d Common (0,148'x 3.',min) Nails at 4' o.c, plus (4) nails In the top and bottom chords. Toenalled Nailsi 10d Common (0,148'x3',m1n) Toenails at 4' o.c. plus (4) toenails In the top and bottom chords, This detail to be used with the appropriate Alpine gable detail for ASCE wind load. ASCE 7-05 Gable Detail Drawings A13015051014, A12015051014, A11015051014, A10015051014, A14015051014, A13030051014, A12030051014, A11030051014, A10030051014, A14030051014 ASCE 7-10 & ASCE 7-16 Gable Detail Drawings A11515ENC100118, A12015ENC100118, A14015ENC100118, A16015ENC100118, A18015ENC100118, A20015ENC100118, A20015END100118, A20015PED100118, A11530ENC100118, A12030ENC100118, A14030ENC100118, A16030ENC100118, A18030ENC100118, A20030ENC100118, A20030ENDI00118, A2003OPED100118, S11515ENC100118, S12015ENC100118, S14015ENC100118, S16015ENCI00118, S18015ENC100118, S20015ENC100118, S20015END10011 t%1SPBft%, S11530ENC100118, S12030ENCI00118, S14030ENC 30 1001 ;ily S18030ENC100118, S20030ENC100118, S20030E O1 f• ggQP ili.( See appropriate Alpine gable detail for maxim ejlfil•c c'�rt W,,wd� 'T' Reinforcement Attachment Detall 'T' Reinforcing 'T' Reinforcing Member Member Toe -null - Or - End -nail To convert from 'L' to 'T' reinforcing members, multiply 'T' Increase by length (based on appropriate Alpine gable detail). Maximum allowable 'T' reinforced gable vertical Length Is 14' from top to bottom chord. 'T' reinforcing member material must match size, specie, and grade of the 'L' reinforcing member. eb Length Increase w/ 'T' Brace Example) ASCE 7-10 Wind Speed = 120 mph Mean Roof Height = 30 ft, Kzt = 1.00 Gable Vertical = 24'o.c. SP #3 'T' Reinforcing Member Size = 2x4 'T' Brace Increase (From Above) = 30% = 1.30 (1) 2x4 'L' Brace Length = 8' 7' Maximum 'T' Reinforced Gable Vertical Length 1.30 x 8' 7 ' = 11 ' 2 ' 'T' Relnf, Mbr, Size 'T' Increase 2x4 30 2x6 20 rwVARNINGrw READ AND FCLLOV ALL NOTES a THIS BRAVING $ ; U. r vv - REF LET -IN VERT "IMPORTANT■w FURNISH THIS DRAWING TO ALL CCNTRACTDRS INCLUDING THE INSTALLERSC w Trusses require extreme care In fabricating, handling, shipping, Installing and bracing Ref "tsA.an$, DATE O1/02/2018 follow the latest edition of BCSI (Building Component Safety Information, by TPI and SBCA) fo s tyw • practices prior to performing these functions. Installers shall provide temporary brndng pe BCSI� 0 _S Unless noted otherwise, top chord shall have property attached structural sheathing and b' m cholo �• �T 4 a DRWG GBLLETIN0118 shall have a properly attached rigid calling. Locations shorn for permanent lateral restraint f s1 shall have bracing Installed per BCSI sections B3, B7 or BIC, as applicable. Apply plates to eJ& of truss and position as shown above and on the Joint Details, unless noted otherwlse� Q, •• • d�.'V AILP' Refer to drawings 160A-Z for standard plate positions. t � thlslpdrnring,Ivnnynfnllure to of ITV ubulld the Components n6conform ace arlth ANSI/TPI lt not be responsible for h.na.ny geshippin r n••w`•rw(�w{*•�•• ANITWCOMPANY Installation & bracing of trusses. MAX, TOT, LD, 60 PSF A seal on this drawing or cover page listing this drawing, Indicates acceptance of professional l� IQ h 1Al. A t 11514\Earth\City\Expressway engineering responsibility solely for the design shown The suitability and use of this drawing 4$�f 11J j-4•& �y �05�2�2� BUR, FAC, ANY \ \ Suite\ 242 for my structure Is the responsibility of the Building Designer per ANSI/TPI 1 Sec2. (, tP \\Earth\City.\MO\63045 For more Information see this Job's general notes page and these web sites MAX, SPACING 24,0' ALPINE www.elpineitw.comi TPA www.tpinst.orgi SBCA, www,sbclndustry.orgl ICG .wraccsafearg Valley Detail - ASCE 7-16: 180 mph, 30' Mean Height, Partially Enc(osed, Exp, C, Kzt=1,00 Top Chord 2x4 SP #2N, SPF #1/#2, DF-L #2 or better, Bot Chord 2x4 SP #2N or SPF #1/#2 or better, Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better, )K)K Attach each valley to every supporting truss with, 535# connection or with (1) Simpson H2,5A or equivalent connector for ASCE 7-16 180 mph, 30' Mean Height, Part, Enc, Building, Exp, C, Wind TC DL=5 psf, Kzt = 1.00 Or ASCE 7-16 160 mph, 30' Mean Height, Part, Enc, Building, Exp, D, Wind TC DL=5 psf, Kzt = 1.00 Bottom chord may be square or pitched cut as shown, Valleys short enough to be cut as solid triangular members from a single 2x6, or larger as required, shall be permitted in lieu of fabricating from separate 2x4 members, All plates shown are Alpine Wave Plates, 3X4 12 Max. 12 2X4 X4 8-0-0 max 4X4 20-0-0 (++) Supporting trusses at 24' o,c, maximum spacing, Unless specified otherwise on engineer's sealed design, for vertical valley webs taller than 7-9' apply 2x4 'T' reinforcement, 80Y length of web, same species and grade or better, attached with 10d box <0.128' x 3,0') nails at 6' o.c, In lieu of 'T' reinforcement, 2x4 Continuous Lateral Restraint applied at mid -length of web is permitted with diagonal bracing as shown in DRWG BRCLBANC1014, Top chord of truss beneath valley set must be braced with, properly attached, rated sheathing applied prior to valley truss Installation, Or Purlins at 24' o,c, or as otherwise specified on engineer's sealed design Or By valley trusses used in lieu of purlin spacing as specified on Engineer's sealed design, xww Note that the purlin spacing for bracing the top chord of the truss beneath the valley is measured along the slope of the top chord, ++ Larger spans may be built as long as the vertical height does not exceed 14'-0'. Pitched Cut Bottom Chord Valley Valle Spacing Square Cut Bottom Chord Vallev Q oL�� �yn,<umluf. SQ H. 2X4 4X4 -�Ir Stubbed Valley ❑Ptional Hip End Detail Joint Detail m in Tr usses Partial Framing t 24' o,c, Plan PI AN ITW COMPANY 11514\ Earth\ City\ Expressway 11 SuitM 242 11 Earth\ City,% MO% 63045 ..VARNWGI. READ AND FOLLDV ALL NOTES GN THIS BRAVING • wwINPQtTANTww FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS t Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer folio• the latest adltlon of BCSI (Building Component Safety Information, by TPI and SBCA) far f • practices prior to performing these functions, Installers shall provide temporary bracing per SI. Unless noted otherwise, top chord shall have properly attached structural sheathing ahard shall have a property attached rigid ceiling. Locations shown for permanent lateral restraint o e}yA shall have bracing Installed per BCSI sections B3, B7 or 1130, as applicable. Apply plates to each n of truss and Position as shown above and on the Joint Details, unless noted otherwise. �.� Refer to drawings I60A-2 for standard plate positions, Alpine, o division of ITV Building Components Group Inc shall not be responsible for any deviation this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, shipping, Installation 4 bracing of trusses. A seal on this drawing or cover page � this drawling, Indkates acceptance of profess ltlMV.3` engineering responslbNt sole, for the de shorn The sWtabalty and use of this draw for any structure Is the respa Witty of the McUrg Designer per ANSI/TPI 1 Sec p- For wmore Information see this ,Job's general notes page and these web sites ALPINE- ww.alpineltw.coml TPD t. www,tpinsorgi SBCAj www,sbcindustry.orgi ICd ,a wwwlccsaferg Q. I V0 i '�' y-. IAr • f1 t i [�V 'C •� I 1J •� ` •os�C Ba ••t.tejjje1•.00 (" � /0$��OZ Nsca LL 30 TC DL 20 $C DL 10 BC LL 0 TOT. LD, 60 30 15 10 0 40 PSF 7 PSF 10 PSF 0 PSF 57PSF REF VALLEY DETAIL DATE O1/26/2018 DRWG VAL180160118 55 DUR,FAC,1,25/1.33 1.15 1.15 SPACING 24,0' Valley Detail - ASCE 7-16: 30' Mean Height, Enclosed, Exp, C, Kzt=1,00 Top Chord 2x4 SP #2N, SPF #1/#2, DF-L #2 or better. Bot Chord 2x4 SP #2N or SPF #1/#2 or better. Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better, �'� Attach each valley to every supporting truss with, (2) 16d box (0,135' x 3,5') nails toe -nailed for ASCE 7-16, 30' Mean Height, Enclosed Building, Exp, C, Wind TC DL=5 psf, Kzt = 1,00, Max, Wind Speed based on supporting truss material at connection location, 170 mph for SP (G = 0.55, min,), 155 mph for DF-L (G = 0,50, min.), or 120 mph for HF & SPF (G = 0,42, min,), Maximum top chord pitch is 10/12 for supporting trusses below valley trusses. Bottom chord of valley trusses may be square or pitched cut as shown, Valleys short enough to be cut as solid triangular members from a single 2x6, or larger as required, shall be permitted in lieu of fabricating from separate 2x4 members, All plates shown are Alpine Wave Plates, 3X4 12 12 Max, I 2X4 X4 12 12 Max, I 1X3 - 8-0-0 max •+ 4X4 9 IX3 (Max Spacing) 5X4/SPL ff _1X3 20-0-0 (++) Supporting trusses at 24' o.c, maximum spacing, Unless specified otherwise on engineer's sealed design, for vertical valley webs taller than 7-9' apply 2x4 'T' reinforcement, 80% length of web, same species and grade or better, attached with 10d . box (0,128' x 3,0') nails at 6' o.c, In lieu of 'T' reinforcement, 2x4 Continuous Lateral Restraint applied at mid -length of web is permitted with diagonal bracing as shown in DRWG BRCLBANC1014, Top chord of truss beneath valley set must be braced with, properly attached, rated sheathing applied prior to valley truss Installation, Or Purlins at 24' o,c, or as otherwise specified on engineer's sealed design Or By valley trusses used in lieu of purlin spacing as specified on Engineer's sealed design, www Note that the purlin spacing for bracing the top chord of the truss beneath the valley is measured along the slope of the top chord, ++ Larger spans may be built as long as the vertical height does not exceed 14'-0'. Valle Spacing Pitched Cut Bottom Chord Valley Itoe-nailed Square Cut Bottom Chord Vallev 10 Max, 1 12 ` r\ 9 � SP��°Nuslls� s oJ' w••��G 2X4 Stubbed Valley End Detail 4X4 ❑Ptional Hip Joint Detail Tru 24' ro� Partial Framing Plan ."ARNwa.. READ AND FOLLOW ALL NOTES DN THIS DRAVINa V. !Uo LL 30 30 40PSF REF VALLEY DETAIL UNWORTANTUN FURNISH THIS DRAWING TO ALL CONTRACTDRS MCLUDD4 THE INSTALLER Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Re'46 mid r TC DL 20 15 7 PSF DATE O1/26/2018 follow the latest edition of BCSI (Building Component Safety Information, by TPI and S1B F e{y • practices prior to performing these functions. Installers shall provide tempornry braUng BCSLw _S Untess noted otherwise, top chord shot( have properly attached structural shenthine and b ton third A� fl - BC DL 10 10 10 PSF DRWG VALTN160118 shall have a properly attached rigid ceiling, Locations sham for permanent lateral restrain of bs shall hove bracing Installed per BCSI sections B3, 17 or 110, as applicable. Apply plates to ea& e*r i `��:'� A PI of truss and position as shown above and on the Joint Details, unless noted otherwise. W (� BC LL 0 0 0 PSF Refer to drawings 160A-Z for standard plate positions. ,/y� �• < ww � ~/ � Alpine, a division of ITV Building Components Group Inc. shall not be responsible for any devlati f �•w� •� TOT, LD, 60 55 57PSF this dra ing, any failure to build the truss In conformance with ANSI/TPI I, or for handling, shi114 A� ••w��wr�w AN lTW COMPANY Installation 6 bracing of trusses. 47 A seal on this drawing or cover page listing this drawing, Indicates acceptance of professional 4 ��/ `N/O5/2021 \\514\Earth\City\Expressway engineering responsibility solely for the design shown.The suitability and use of this drawing 'Vy� , DUR,FAC. 1,25/1.33 1.15 1,15 \\Suite\242 For any structure Is the responsibility of the Building Designer per ANSI/TPI 1 SecZ jln9plyyi \\Earth\ City.\ MO\ 63045 For more Information see this Job's general notes page and these web sitesr SPACING 24,0' ALPINEi www.alpineltw.comi TPB www.tpinst.orgi SBCAi www.sbcindustry.orgi ICG wwwJccsafe.org VALLEY FRAMING & BRACING DETAIL L W Lumber Size and Grade Minumum Requirements GENERAL NOTES Purlins required 2'-0" O.C. in absence of plywood sheathing. Trusses without sheathing applied must be evaluated accordingly. Purlins should overlap sheathing one truss spacing minimum. In cases that this is impractical, overlap sheathing a minimum of 6", and nail upwards through sheathing into purlin with a minimum of 8-8d (0.131"x2.5") common wire nails. Effects of not providing sheathing below a valley set must be evaluated by the building designer. This drawing applies to valleys with the following conditions: Spans (distance between heels) 40'-0" or less -Maximum valley height: W-0" -Maximum mean roof height: 30 feet -ASCE 7-05, 140 mph, Enclosed, Cat II, Exp B, 1=1.0, Kzt=1.0 -Or A Maximum of ASCE 7-10, 180 mph, Enclosed, Exp D, Kzt=1.0 TRUSS TRUSS UNDER VALLEY FRAMING VALLEY RAFTER OR RIDGE ® +CRIPPLE ripples 41-0" for 30 psf (TL)'and 20 psf (TD) Max. ce the crippes for each row starting from the valleys or sleepers working Inward to the ridge board so that cripple locations are gored between rows. (Typ) innection Requirement Notes 2x6 rafters to ridge 4 16d toe -nails Cripple to ridge 4 16d toe -nails Cripple to rafter 416d toe -nails (•e) 816d face -nails Rafter to sleeper or blocking 516d toe -nails Rafter to two 2x6 sleepers 416d toe -nails Sleeper to truss 416d toe -nails Two 2x6 sleepers to truss 316d toe -nails each sleeper & truss Ridge board to roof block 416d toe -nails Ridge board to truss 416d toe -nails Purlin to (Typ) 316d toe -nails Truss to blocking 416d toe -nails Truss to cripple 416d toe -nails Truss to cripple 416d toe -nails Cri pieta urlin 3 16d toe -nails P P taw i nc—m— Ir aLccreKb AKc urtu) 13. Collar beam to rafter 416d toe -nails CRIPPLE, BRACING, & BLOCKING NOTES NOTE: 16d (0.162"x3.5") COMMON NAILS -2x4 continuous lateral restraint (CLR) min. is required for cripples V-0" to 10'-0" long nailed w/ 2 -10d (0.148"x3") nails. Or 20 "T" or scab reinforcement nailed to flat edge of cri Cr�ple with 10d f0.128"x3.0") nails at 6" o.c. "T' or scab must be 90 % of cripple length. ipp es over 10'-0' long requre two CLR's or both faces w/ "T". or scab. Use stress graded lumber & box or common nails. Narrow edge of cripple can face ridge or rafter, as long as the proper number of nails are installed Into ridge board -install blocking under rafter if sleepers are not used. -Install blocking under cripples If cripples fall between lower truss top chords and lateral bracing is not used. -Apply all nailing in accordance to current NDS requireme Nails are common wire nails unless noted otherwise. C H. (A) (B) C LL 20 30 40 54 REF VALLEY FRAMING �Tfrrr® rlsaasa TF� nanvDi� To eu raflRacToits rr+� �� tic n+STeLLfxs. s Trusses require extreme care h fabricotkV, hndlllnp, shlppbV, Installhg and broUnp , Refer to fdto. the latest astlm of BCSI eBA&V f-4—nt Safety Info —tan, by TPI and SDW for 6Wety ; C DL 10 20 7 7 DATE 10/O1/14 practices prior to perfornkV these functlor Installers shall provide tenporry bracing per I.W.• LWass noted othe lse, top chrd shall have property attached structural sheathing and bottoi$c a • sialt have a property attached Hold ceebq. Locations shown far s e `STATE • �� BC DL 0 0 0 0 DRWG VACNV1801015 rhshall have brackg krstalted per BCSI seetlom 113, 87 or B30 as appl e. tApply platen tto each } �a A f e d �� of truss and po.m— as shown above and on the Jdnt Details, unless noted otherwise. "e o Imo_ 1 A _ R.f.r to dra.arps 16M-Z for standard plate posrd... ee .• `ee • ��`�, BC LL 0 0 0 0 AN iTWCX)MTMNY Nam' a dMslcn of ITV B Adlno Components Croup Inc shalt not be mspansWe Fr ry deviation f e * •� o lO• e F this di -owing, any falum to build the truss In eonfornonce wtth AMSI/TPI 1, r fr handlkq, shipping; i �� TOT. LD.30 50 47 61 Mstalatbn L bra o eno� t �this � �����,0, or ce sor aW Us�g ahis dram,., motes a�.pmnce of professlonol 'f9h ,OIYAL ,tgt�t 133B9 Laketrent Drive `°'' °+1' stet *- _T ie the resporw:bahty � Du dkbv Dwslgr r��per�•h�6t�e i seez �°�'0 " DUR. FAC. 1.25/1.15 Earth City, MO 63045 For nor* W.—Von see this Job's general rates page and these w.b sites+ ac, wwwa a-Ptpkxltw.corp TPI, e.etpr,:targ, SBp4 ....mcPndustryarg, 100 w...klsafeorg 10 2 O°( 5___ SPACING SEE ABOVE