APPROVED, 17-015-078 Truss Engineering
Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. RE: Job CRMSWSB2 Page 1 of 2 A-1 Roof Trusses 4451 St Lucie Blvd Fort Pierce, FL 34946Site Information: Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE Lot/Block:Model: WILSHIRE 1800 Subdivision: Address: City: County: St Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC 7th Ed. 2020 Res. / TPI 2014 Design Program: Alpine Engineered Products Wind Code: ASCE 7-16 Wind Speed: 160 Roof Load: 37.0 psf Floor Load: 55.0 psf This package includes 41 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. The truss drawing(s) referenced have been prepared by Alpine Engineered Products, Inc. under my direct supervision based on the parameters provided by A-1 Roof Trusses, Ltd. Truss Design Engineer's Name: Ryan Bays My license renewal date for the state of Florida is February 28,2023. NOTE: The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of components for any particular building is the responsibility of the building designer, per ANSI/TPI-1 Sec. 2. The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction documents (also referred to at times as 'Structural Engineering Documents') provided by the Building Designer indicating the nature and character of the work. The design criteria therein have been transferred to Ryan Bays PE by [A1 Roof Trusses or specific location]. These TDDs (also referred to at times as 'Structural Delegated' Engineering Documents') are specialty structural component designs and may be part of the project's deferred or phased submittals. As a Truss Design Engineer (i.e., Specialty Engineer), the seal here and on the TDD represents an acceptance of professional engineering responsibility for the design of the single Truss depicted on the TDD only. The Building Designer is responsible for and shall coordinate and review the TDDs for compatibility with their written engineering requirements. Please review all TDDs and all related notes. Ryan Bays, P.E. 4451 St Lucie Blvd. Suite 201 Fort Pierce, FL 34946 No.Seq #Truss Name Date 1 2514 A01 5/29/21 2 2490 A02 5/29/21 3 2491 A03 5/29/21 4 2492 A04 5/29/21 5 2493 A05 5/29/21 6 2494 A06 5/29/21 7 2495 A07 5/29/21 8 2496 A08 5/29/21 9 2515 A09 5/29/21 10 2516 B01 5/29/21 11 2497 B02 5/29/21 12 2518 B03 5/29/21 No.Seq #Truss Name Date 13 2564 FG02 5/29/21 14 2551 FG03 5/29/21 15 2554 FG05 5/29/21 16 2537 FL01 5/29/21 17 2538 FL01GE 5/29/21 18 2539 FL02 5/29/21 19 2540 FL02GE 5/29/21 20 2541 FL03 5/29/21 21 2542 FL05 5/29/21 22 2543 FL05GE 5/29/21 23 2544 FL06 5/29/21 24 2552 FL07G 5/29/21 No.Seq #Truss Name Date 25 2545 FL08 5/29/21 26 2546 FL09 5/29/21 27 2547 FL10GE 5/29/21 28 2548 FL11 5/29/21 29 2549 FL11A 5/29/21 30 2550 FL11GE 5/29/21 31 2511 HJ3P 5/29/21 32 2513 HJ7 5/29/21 33 2500 J1 5/29/21 34 2502 J3 5/29/21 35 2535 J3P 5/29/21 36 2504 J4P 5/29/21 Lumber design values are in accordance with ANSI/TPI 1-2014 section 6.3 These truss designs rely on lumber values established by others. RE: Job CRMSWSB2 Page 2 of 2 No.Seq #Truss Name Date 37 2505 J5 5/29/21 38 2507 J7 5/29/21 39 2508 V01 5/29/21 40 2509 V02 5/29/21 41 2510 V03 5/29/21 42 STDL01 STD. DETAIL 5/29/21 43 STDL02 STD. DETAIL 5/29/21 44 STDL03 STD. DETAIL 5/29/21 45 STDL04 STD. DETAIL 5/29/21 46 STDL05 STD. DETAIL 5/29/21 47 STDL06 STD. DETAIL 5/29/21 48 STDL07 STD. DETAIL 5/29/21 49 STDL08 STD. DETAIL 5/29/21 50 STDL09 STD. DETAIL 5/29/21 51 STDL10 STD. DETAIL 5/29/21 52 STDL11 STD. DETAIL 5/29/21 53 STDL12 STD. DETAIL 5/29/21 54 STDL13 STD. DETAIL 5/29/21 55 STDL14 STD. DETAIL 5/29/21 56 STDL15 STD. DETAIL 5/29/21 57 STDL16 STD. DETAIL 5/29/21 Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; T2 2x4 SP M-30; Bot chord: 2x4 SP M-30; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 62 plf at -1.46 to 62 plf at 7.00 TC: From 31 plf at 7.00 to 31 plf at 19.67 TC: From 62 plf at 19.67 to 62 plf at 28.13 BC: From 14 plf at 0.00 to 14 plf at 7.03 BC: From 7 plf at 7.03 to 7 plf at 19.64 BC: From 14 plf at 19.64 to 14 plf at 26.67 TC: 254 lb Conc. Load at 7.03,19.64 TC: 186 lb Conc. Load at 9.06,11.06,13.06,13.60 15.60,17.60 BC: 442 lb Conc. Load at 7.03,19.64 BC: 111 lb Conc. Load at 9.06,11.06,13.06,13.60 15.60,17.60 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 7.00 19.67 BC 59 0.15 26.52 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2451 /- /- /- /1186 /- F 2451 /- /- /- /1186 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 2.9 F Brg Width = 3.5 Min Req = 2.9 Bearings B & F are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 -25 B - C 2265 -4661 C - D 2651 -5435 Chords Tens. Comp. D - E 2651 -5435 E - F 2265 -4661 F - G 39 -25 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - K 4081 -1972 K - J 4106 -1974 J - I 4106 -1974 Chords Tens. Comp. I - H 4106 -1974 H - F 4081 -1972 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - K 589 -71 C - J 1522 -775 D - J 785 -977 Webs Tens. Comp. J - E 1522 -775 H - E 589 -71 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.267 D 999 360 VERT(CL): 0.495 D 639 240 HORZ(LL): 0.078 H - - HORZ(TL): 0.146 H - - Creep Factor: 2.0 Max TC CSI: 0.945 Max BC CSI: 0.951 Max Web CSI: 0.735 Weight: 123.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A01 Truss Type HIPS Qty 1 Ply 1 Seal #: 2514 05/29/2021 26'8" 7'12'8"7' 1'5-9/16"1'5-9/16" 4-3/16"3'10-3/16"4'5-15/16"A B C D E F G HIJK 6 12 4X8(B3) 6X8 2X4 3X4 4X8 H0308 2X4 6X8 4X8(B3) 7'0-3/8" 442# 254# 2'0-3/8" 111# 186# 2' 111# 186# 2' 111# 186# 6-1/2" 111# 186# 2' 111# 186# 2' 111# 186# 2'0-3/8" 442# 254# 7'0-3/8" **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; T2 2x4 SP M-30; Bot chord: 2x4 SP M-30; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 62 plf at -1.46 to 62 plf at 7.00 TC: From 31 plf at 7.00 to 31 plf at 19.67 TC: From 62 plf at 19.67 to 62 plf at 28.13 BC: From 14 plf at 0.00 to 14 plf at 7.03 BC: From 7 plf at 7.03 to 7 plf at 19.64 BC: From 14 plf at 19.64 to 14 plf at 26.67 TC: 254 lb Conc. Load at 7.03,19.64 TC: 186 lb Conc. Load at 9.06,11.06,13.06,13.60 15.60,17.60 BC: 442 lb Conc. Load at 7.03,19.64 BC: 111 lb Conc. Load at 9.06,11.06,13.06,13.60 15.60,17.60 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 7.00 19.67 BC 59 0.15 26.52 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2451 /- /- /- /1186 /- F 2451 /- /- /- /1186 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 2.9 F Brg Width = 3.5 Min Req = 2.9 Bearings B & F are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 -25 B - C 2265 -4661 C - D 2651 -5435 Chords Tens. Comp. D - E 2651 -5435 E - F 2265 -4661 F - G 39 -25 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - K 4081 -1972 K - J 4106 -1974 J - I 4106 -1974 Chords Tens. Comp. I - H 4106 -1974 H - F 4081 -1972 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - K 589 -71 C - J 1522 -775 D - J 785 -977 Webs Tens. Comp. J - E 1522 -775 H - E 589 -71 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.267 D 999 360 VERT(CL): 0.495 D 639 240 HORZ(LL): 0.078 H - - HORZ(TL): 0.146 H - - Creep Factor: 2.0 Max TC CSI: 0.945 Max BC CSI: 0.951 Max Web CSI: 0.735 Weight: 123.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A01 Truss Type HIPS Qty 1 Ply 1 Seal #: 2514 05/29/2021 26'8" 7'12'8"7' 1'5-9/16"1'5-9/16" 4-3/16"3'10-3/16"4'5-15/16"A B C D E F G HIJK 6 12 4X8(B3) 6X8 2X4 3X4 4X8 H0308 2X4 6X8 4X8(B3) 7'0-3/8" 442# 254# 2'0-3/8" 111# 186# 2' 111# 186# 2' 111# 186# 6-1/2" 111# 186# 2' 111# 186# 2' 111# 186# 2'0-3/8" 442# 254# 7'0-3/8" Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 119 0.15 26.54 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1109 /- /- /619 /257 /203 G 1015 /- /- /534 /228 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 G Brg Width = - Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 671 -1765 C - D 686 -1590 Chords Tens. Comp. D - E 706 -1521 E - F 723 -1605 F - G 688 -1780 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 1504 -529 J - I 1005 -268 Chords Tens. Comp. I - H 1005 -268 H - G 1521 -523 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - J 293 -377 J - E 589 -228 Webs Tens. Comp. E - H 608 -243 H - F 299 -387 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.073 J 999 360 VERT(CL): 0.137 J 999 240 HORZ(LL): 0.029 H - - HORZ(TL): 0.055 H - - Creep Factor: 2.0 Max TC CSI: 0.492 Max BC CSI: 0.999 Max Web CSI: 0.320 Weight: 119.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A02 Truss Type COMN Qty 3 Ply 1 Seal #: 2490 05/29/2021 26'8" 13'4"13'4" 1'5-9/16" 4-3/16"7'0-3/16"7'7-15/16"A B C D E F G HIJ 6 12 3X4(A1) 1.5X3 3X4 3X6 4X6 4X4 3X4 1.5X3 3X4(A1) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 119 0.15 26.54 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1109 /- /- /619 /257 /203 G 1015 /- /- /534 /228 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 G Brg Width = - Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 671 -1765 C - D 686 -1590 Chords Tens. Comp. D - E 706 -1521 E - F 723 -1605 F - G 688 -1780 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 1504 -529 J - I 1005 -268 Chords Tens. Comp. I - H 1005 -268 H - G 1521 -523 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - J 293 -377 J - E 589 -228 Webs Tens. Comp. E - H 608 -243 H - F 299 -387 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.073 J 999 360 VERT(CL): 0.137 J 999 240 HORZ(LL): 0.029 H - - HORZ(TL): 0.055 H - - Creep Factor: 2.0 Max TC CSI: 0.492 Max BC CSI: 0.999 Max Web CSI: 0.320 Weight: 119.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A02 Truss Type COMN Qty 3 Ply 1 Seal #: 2490 05/29/2021 26'8" 13'4"13'4" 1'5-9/16" 4-3/16"7'0-3/16"7'7-15/16"A B C D E F G HIJ 6 12 3X4(A1) 1.5X3 3X4 3X6 4X6 4X4 3X4 1.5X3 3X4(A1) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.00 17.67 BC 86 0.15 26.52 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1105 /- /- /622 /484 /161 E 1105 /- /- /622 /484 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 E Brg Width = 3.5 Min Req = 1.5 Bearings B & E are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 1028 -1664 C - D 1022 -1399 Chords Tens. Comp. D - E 1028 -1666 E - F 39 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 1390 -761 I - H 1396 -762 Chords Tens. Comp. H - G 1396 -762 G - E 1392 -764 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - I 307 0 I - D 144 -139 Webs Tens. Comp. G - D 305 0 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.060 G 999 360 VERT(CL): 0.113 G 999 240 HORZ(LL): 0.030 G - - HORZ(TL): 0.055 G - - Creep Factor: 2.0 Max TC CSI: 0.914 Max BC CSI: 0.973 Max Web CSI: 0.239 Weight: 114.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A03 Truss Type HIPS Qty 1 Ply 1 Seal #: 2491 05/29/2021 26'8" 9'8'8"9' 1'5-9/16"1'5-9/16" 4-3/16"4'10-3/16"5'5-15/16"A B C D E F GHI 6 12 3X4(A1) 6X6 3X4 3X6 1.5X3 7X6(R) 3X4(A1) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.00 17.67 BC 86 0.15 26.52 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1105 /- /- /622 /484 /161 E 1105 /- /- /622 /484 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 E Brg Width = 3.5 Min Req = 1.5 Bearings B & E are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 1028 -1664 C - D 1022 -1399 Chords Tens. Comp. D - E 1028 -1666 E - F 39 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 1390 -761 I - H 1396 -762 Chords Tens. Comp. H - G 1396 -762 G - E 1392 -764 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - I 307 0 I - D 144 -139 Webs Tens. Comp. G - D 305 0 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.060 G 999 360 VERT(CL): 0.113 G 999 240 HORZ(LL): 0.030 G - - HORZ(TL): 0.055 G - - Creep Factor: 2.0 Max TC CSI: 0.914 Max BC CSI: 0.973 Max Web CSI: 0.239 Weight: 114.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A03 Truss Type HIPS Qty 1 Ply 1 Seal #: 2491 05/29/2021 26'8" 9'8'8"9' 1'5-9/16"1'5-9/16" 4-3/16"4'10-3/16"5'5-15/16"A B C D E F GHI 6 12 3X4(A1) 6X6 3X4 3X6 1.5X3 7X6(R) 3X4(A1) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 11.00 15.67 BC 87 0.15 26.52 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1105 /- /- /624 /482 /188 G 1105 /- /- /624 /482 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 G Brg Width = 3.5 Min Req = 1.5 Bearings B & G are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 870 -1691 C - D 808 -1387 D - E 756 -1177 Chords Tens. Comp. E - F 808 -1387 F - G 870 -1691 G - H 39 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - K 1433 -636 K - J 1177 -447 Chords Tens. Comp. J - I 1177 -447 I - G 1433 -639 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - K 301 -423 D - K 396 -158 Webs Tens. Comp. E - I 396 -157 I - F 301 -423 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.108 I 999 360 VERT(CL): 0.262 I 999 240 HORZ(LL): 0.045 D - - HORZ(TL): 0.109 D - - Creep Factor: 2.0 Max TC CSI: 0.704 Max BC CSI: 0.973 Max Web CSI: 0.230 Weight: 119.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A04 Truss Type HIPS Qty 1 Ply 1 Seal #: 2492 05/29/2021 26'8" 11'4'8"11' 1'5-9/16"1'5-9/16" 4-3/16"5'10-3/16"6'5-15/16"A B C D E F G H IJK 6 12 3X4(A1) 1.5X3 5X6 3X4 3X6 5X6 3X4 1.5X3 3X4(A1) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 11.00 15.67 BC 87 0.15 26.52 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1105 /- /- /624 /482 /188 G 1105 /- /- /624 /482 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 G Brg Width = 3.5 Min Req = 1.5 Bearings B & G are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 870 -1691 C - D 808 -1387 D - E 756 -1177 Chords Tens. Comp. E - F 808 -1387 F - G 870 -1691 G - H 39 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - K 1433 -636 K - J 1177 -447 Chords Tens. Comp. J - I 1177 -447 I - G 1433 -639 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - K 301 -423 D - K 396 -158 Webs Tens. Comp. E - I 396 -157 I - F 301 -423 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.108 I 999 360 VERT(CL): 0.262 I 999 240 HORZ(LL): 0.045 D - - HORZ(TL): 0.109 D - - Creep Factor: 2.0 Max TC CSI: 0.704 Max BC CSI: 0.973 Max Web CSI: 0.230 Weight: 119.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A04 Truss Type HIPS Qty 1 Ply 1 Seal #: 2492 05/29/2021 26'8" 11'4'8"11' 1'5-9/16"1'5-9/16" 4-3/16"5'10-3/16"6'5-15/16"A B C D E F G H IJK 6 12 3X4(A1) 1.5X3 5X6 3X4 3X6 5X6 3X4 1.5X3 3X4(A1) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.15 26.52 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1105 /- /- /619 /247 /216 H 1105 /- /- /619 /247 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 H Brg Width = 3.5 Min Req = 1.5 Bearings B & H are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 640 -1756 C - D 646 -1581 D - E 675 -1563 Chords Tens. Comp. E - F 675 -1551 F - G 648 -1582 G - H 640 -1757 H - I 39 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 1496 -442 L - K 999 -181 Chords Tens. Comp. K - J 999 -181 J - H 1497 -445 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - L 295 -374 L - E 589 -233 Webs Tens. Comp. E - J 589 -233 J - G 295 -375 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.074 J 999 360 VERT(CL): 0.137 J 999 240 HORZ(LL): 0.029 J - - HORZ(TL): 0.054 J - - Creep Factor: 2.0 Max TC CSI: 0.455 Max BC CSI: 0.855 Max Web CSI: 0.307 Weight: 121.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A05 Truss Type HIPS Qty 1 Ply 1 Seal #: 2493 05/29/2021 26'8" 13'8"13' 1'5-9/16"1'5-9/16" 4-3/16"6'10-3/16"7'5-15/16"A B C D E F G H I JKL 6 12 3X4(A1) 1.5X3 3X6 3X4 4X6 4X6(R) 3X4 3X6 1.5X3 3X4(A1) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.15 26.52 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1105 /- /- /619 /247 /216 H 1105 /- /- /619 /247 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 H Brg Width = 3.5 Min Req = 1.5 Bearings B & H are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 640 -1756 C - D 646 -1581 D - E 675 -1563 Chords Tens. Comp. E - F 675 -1551 F - G 648 -1582 G - H 640 -1757 H - I 39 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 1496 -442 L - K 999 -181 Chords Tens. Comp. K - J 999 -181 J - H 1497 -445 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - L 295 -374 L - E 589 -233 Webs Tens. Comp. E - J 589 -233 J - G 295 -375 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.074 J 999 360 VERT(CL): 0.137 J 999 240 HORZ(LL): 0.029 J - - HORZ(TL): 0.054 J - - Creep Factor: 2.0 Max TC CSI: 0.455 Max BC CSI: 0.855 Max Web CSI: 0.307 Weight: 121.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A05 Truss Type HIPS Qty 1 Ply 1 Seal #: 2493 05/29/2021 26'8" 13'8"13' 1'5-9/16"1'5-9/16" 4-3/16"6'10-3/16"7'5-15/16"A B C D E F G H I JKL 6 12 3X4(A1) 1.5X3 3X6 3X4 4X6 4X6(R) 3X4 3X6 1.5X3 3X4(A1) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.15 26.54 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1109 /- /- /620 /248 /199 G 1015 /- /- /535 /219 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 G Brg Width = - Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 648 -1765 C - D 664 -1590 Chords Tens. Comp. D - E 683 -1521 E - F 696 -1605 F - G 662 -1780 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 1504 -510 J - I 1006 -245 Chords Tens. Comp. I - H 1006 -245 H - G 1522 -499 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - J 297 -376 J - E 589 -232 Webs Tens. Comp. E - H 608 -247 H - F 303 -386 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.073 J 999 360 VERT(CL): 0.137 J 999 240 HORZ(LL): 0.029 H - - HORZ(TL): 0.055 H - - Creep Factor: 2.0 Max TC CSI: 0.492 Max BC CSI: 0.941 Max Web CSI: 0.324 Weight: 119.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A06 Truss Type HIPS Qty 1 Ply 1 Seal #: 2494 05/29/2021 26'8" 13'8"13' 1'5-9/16" 4-3/16"6'10-3/16"7'5-15/16"A B C D E F G HIJ 6 12 3X4(A1) 1.5X3 3X4 3X6 4X6 4X6(R) 3X4 1.5X3 3X4(A1) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.15 26.54 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Loading Truss passed check for 20 psf additional bottom chord live load in areas with 42"-high x 24"-wide clearance. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1109 /- /- /620 /248 /199 G 1015 /- /- /535 /219 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 G Brg Width = - Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 648 -1765 C - D 664 -1590 Chords Tens. Comp. D - E 683 -1521 E - F 696 -1605 F - G 662 -1780 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 1504 -510 J - I 1006 -245 Chords Tens. Comp. I - H 1006 -245 H - G 1522 -499 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - J 297 -376 J - E 589 -232 Webs Tens. Comp. E - H 608 -247 H - F 303 -386 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.073 J 999 360 VERT(CL): 0.137 J 999 240 HORZ(LL): 0.029 H - - HORZ(TL): 0.055 H - - Creep Factor: 2.0 Max TC CSI: 0.492 Max BC CSI: 0.941 Max Web CSI: 0.324 Weight: 119.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A06 Truss Type HIPS Qty 1 Ply 1 Seal #: 2494 05/29/2021 26'8" 13'8"13' 1'5-9/16" 4-3/16"6'10-3/16"7'5-15/16"A B C D E F G HIJ 6 12 3X4(A1) 1.5X3 3X4 3X6 4X6 4X6(R) 3X4 1.5X3 3X4(A1) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; T4 2x4 SP M-30; Bot chord: 2x4 SP #2; B2 2x4 SP 2400f-2.0E + SP M-31; Webs: 2x4 SP #3; Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 11.00 15.67 TC 24 18.52 26.67 BC 76 0.15 26.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1114 /- /- /648 /467 /245 I 1010 /- /- /480 /448 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 I Brg Width = - Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 990 -1783 C - D 866 -1418 D - E 849 -1206 Chords Tens. Comp. E - F 910 -1384 F - G 956 -1440 G - H 5 -5 G - I 1097 -1557 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 1536 -1009 L - K 1199 -779 Chords Tens. Comp. K - J 1199 -779 J - I 1379 -970 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - L 308 -384 D - L 323 -91 D - J 101 -64 Webs Tens. Comp. J - E 391 -210 J - F 357 -308 H - I 286 -236 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.069 L 999 360 VERT(CL): 0.130 L 999 240 HORZ(LL): 0.028 J - - HORZ(TL): 0.053 J - - Creep Factor: 2.0 Max TC CSI: 0.625 Max BC CSI: 0.998 Max Web CSI: 0.282 Weight: 145.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A07 Truss Type SPEC Qty 1 Ply 1 Seal #: 2495 05/29/2021 26'8" 11'4'8"2'10"8'2" 15'8"10'8-1/2"3-1/2" 1'5-9/16" 4-3/16"4'5-7/16"5'10-3/16"6'5-15/16"A B C D E FG H I JKL 6 12 3X4(A1) 5X6 3X4 4X6 3X8 5X6 1.5X4 1.5X4 3X6(R) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; T4 2x4 SP M-30; Bot chord: 2x4 SP #2; B2 2x4 SP 2400f-2.0E + SP M-31; Webs: 2x4 SP #3; Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 11.00 15.67 TC 24 18.52 26.67 BC 76 0.15 26.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1114 /- /- /648 /467 /245 I 1010 /- /- /480 /448 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 I Brg Width = - Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 990 -1783 C - D 866 -1418 D - E 849 -1206 Chords Tens. Comp. E - F 910 -1384 F - G 956 -1440 G - H 5 -5 G - I 1097 -1557 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 1536 -1009 L - K 1199 -779 Chords Tens. Comp. K - J 1199 -779 J - I 1379 -970 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - L 308 -384 D - L 323 -91 D - J 101 -64 Webs Tens. Comp. J - E 391 -210 J - F 357 -308 H - I 286 -236 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.069 L 999 360 VERT(CL): 0.130 L 999 240 HORZ(LL): 0.028 J - - HORZ(TL): 0.053 J - - Creep Factor: 2.0 Max TC CSI: 0.625 Max BC CSI: 0.998 Max Web CSI: 0.282 Weight: 145.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A07 Truss Type SPEC Qty 1 Ply 1 Seal #: 2495 05/29/2021 26'8" 11'4'8"2'10"8'2" 15'8"10'8-1/2"3-1/2" 1'5-9/16" 4-3/16"4'5-7/16"5'10-3/16"6'5-15/16"A B C D E FG H I JKL 6 12 3X4(A1) 5X6 3X4 4X6 3X8 5X6 1.5X4 1.5X4 3X6(R) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; T1 2x4 SP M-30; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.00 26.67 BC 73 0.15 26.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1114 /- /- /651 /470 /265 H 1010 /- /- /488 /463 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 H Brg Width = - Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 1075 -1662 C - D 1069 -1400 Chords Tens. Comp. D - E 994 -1266 E - F 994 -1266 F - G 0 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - K 1382 -1058 K - J 1520 -1271 Chords Tens. Comp. J - I 1520 -1271 I - H 891 -799 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - K 350 -187 K - D 343 -176 D - I 405 -372 Webs Tens. Comp. I - F 581 -285 F - H 1129 -1259 G - H 85 -69 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.061 D 999 360 VERT(CL): 0.115 D 999 240 HORZ(LL): 0.027 H - - HORZ(TL): 0.051 H - - Creep Factor: 2.0 Max TC CSI: 0.829 Max BC CSI: 0.969 Max Web CSI: 0.981 Weight: 137.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A08 Truss Type HIPM Qty 1 Ply 1 Seal #: 2496 05/29/2021 26'8" 9'17'8" 1'5-9/16" 4-3/16"4'10-3/16"5'5-15/16"A B C D E F G HIJK 6 12 3X4(A1) 5X6 3X4 3X6 3X4 3X4 3X6 3X4 1.5X3 3X6(R) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; T1 2x4 SP M-30; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.00 26.67 BC 73 0.15 26.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1114 /- /- /651 /470 /265 H 1010 /- /- /488 /463 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 H Brg Width = - Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 1075 -1662 C - D 1069 -1400 Chords Tens. Comp. D - E 994 -1266 E - F 994 -1266 F - G 0 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - K 1382 -1058 K - J 1520 -1271 Chords Tens. Comp. J - I 1520 -1271 I - H 891 -799 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - K 350 -187 K - D 343 -176 D - I 405 -372 Webs Tens. Comp. I - F 581 -285 F - H 1129 -1259 G - H 85 -69 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.061 D 999 360 VERT(CL): 0.115 D 999 240 HORZ(LL): 0.027 H - - HORZ(TL): 0.051 H - - Creep Factor: 2.0 Max TC CSI: 0.829 Max BC CSI: 0.969 Max Web CSI: 0.981 Weight: 137.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A08 Truss Type HIPM Qty 1 Ply 1 Seal #: 2496 05/29/2021 26'8" 9'17'8" 1'5-9/16" 4-3/16"4'10-3/16"5'5-15/16"A B C D E F G HIJK 6 12 3X4(A1) 5X6 3X4 3X6 3X4 3X4 3X6 3X4 1.5X3 3X6(R) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 :SP 2400f-2.0E + SP M-31:; T1 2x4 SP #2; Bot chord: 2x4 SP M-30; Webs: 2x4 SP #3; W3 2x4 SP #2; Bracing (a) Continuous lateral restraint equally spaced on member. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 62 plf at -1.46 to 62 plf at 7.00 TC: From 31 plf at 7.00 to 31 plf at 26.67 BC: From 14 plf at 0.00 to 14 plf at 7.03 BC: From 7 plf at 7.03 to 7 plf at 26.67 TC: 254 lb Conc. Load at 7.03 TC: 186 lb Conc. Load at 9.06,11.06,13.06,15.06 17.06,19.06,21.06,23.06,25.06 BC: 442 lb Conc. Load at 7.03 BC: 111 lb Conc. Load at 9.06,11.06,13.06,15.06 17.06,19.06,21.06,23.06,25.06 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 7.00 26.67 BC 61 0.15 26.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2319 /- /- /- /1123 /- H 2424 /- /- /- /1184 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 2.7 H Brg Width = - Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 -25 B - C 2134 -4388 C - D 2406 -4929 Chords Tens. Comp. D - E 2405 -4928 E - F 2405 -4928 F - G 1768 -3641 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 3839 -1857 L - K 3864 -1860 K - J 3767 -1851 Chords Tens. Comp. J - I 3767 -1851 I - H 31 -16 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - L 606 -71 C - K 1208 -619 D - K 636 -804 K - F 1332 -635 Webs Tens. Comp. F - I 1016 -1550 I - G 4120 -2001 G - H 1194 -2285 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.235 D 999 360 VERT(CL): 0.436 D 729 240 HORZ(LL): 0.056 C - - HORZ(TL): 0.105 C - - Creep Factor: 2.0 Max TC CSI: 0.903 Max BC CSI: 0.957 Max Web CSI: 0.930 Weight: 133.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A09 Truss Type HIPM Qty 1 Ply 1 Seal #: 2515 05/29/2021 26'8" 7'19'8" 1'5-9/16" 4-3/16"3'10-3/16"4'5-15/16"(a) A B C D E F G HIJKL 6 12 3X10(B3) 6X8 2X4 2X4 4X8 H0308 H0308 4X4 5X8 5X8 3X6 7'0-3/8" 442# 254# 2'0-3/8" 111# 186# 2' 111# 186# 2' 111# 186# 2' 111# 186# 2' 111# 186# 2' 111# 186# 2' 111# 186# 2' 111# 186# 2' 111# 186#1'7-1/4" **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 :SP 2400f-2.0E + SP M-31:; T1 2x4 SP #2; Bot chord: 2x4 SP M-30; Webs: 2x4 SP #3; W3 2x4 SP #2; Bracing (a) Continuous lateral restraint equally spaced on member. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 62 plf at -1.46 to 62 plf at 7.00 TC: From 31 plf at 7.00 to 31 plf at 26.67 BC: From 14 plf at 0.00 to 14 plf at 7.03 BC: From 7 plf at 7.03 to 7 plf at 26.67 TC: 254 lb Conc. Load at 7.03 TC: 186 lb Conc. Load at 9.06,11.06,13.06,15.06 17.06,19.06,21.06,23.06,25.06 BC: 442 lb Conc. Load at 7.03 BC: 111 lb Conc. Load at 9.06,11.06,13.06,15.06 17.06,19.06,21.06,23.06,25.06 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 7.00 26.67 BC 61 0.15 26.67 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Wind Wind loads and reactions based on MWFRS. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 2319 /- /- /- /1123 /- H 2424 /- /- /- /1184 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 2.7 H Brg Width = - Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 -25 B - C 2134 -4388 C - D 2406 -4929 Chords Tens. Comp. D - E 2405 -4928 E - F 2405 -4928 F - G 1768 -3641 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - L 3839 -1857 L - K 3864 -1860 K - J 3767 -1851 Chords Tens. Comp. J - I 3767 -1851 I - H 31 -16 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - L 606 -71 C - K 1208 -619 D - K 636 -804 K - F 1332 -635 Webs Tens. Comp. F - I 1016 -1550 I - G 4120 -2001 G - H 1194 -2285 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.235 D 999 360 VERT(CL): 0.436 D 729 240 HORZ(LL): 0.056 C - - HORZ(TL): 0.105 C - - Creep Factor: 2.0 Max TC CSI: 0.903 Max BC CSI: 0.957 Max Web CSI: 0.930 Weight: 133.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss A09 Truss Type HIPM Qty 1 Ply 1 Seal #: 2515 05/29/2021 26'8" 7'19'8" 1'5-9/16" 4-3/16"3'10-3/16"4'5-15/16"(a) A B C D E F G HIJKL 6 12 3X10(B3) 6X8 2X4 2X4 4X8 H0308 H0308 4X4 5X8 5X8 3X6 7'0-3/8" 442# 254# 2'0-3/8" 111# 186# 2' 111# 186# 2' 111# 186# 2' 111# 186# 2' 111# 186# 2' 111# 186# 2' 111# 186# 2' 111# 186# 2' 111# 186#1'7-1/4" Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; T2 2x4 SP M-30; Bot chord: 2x4 SP M-30; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 62 plf at -1.46 to 62 plf at 7.00 TC: From 31 plf at 7.00 to 31 plf at 12.33 TC: From 62 plf at 12.33 to 62 plf at 20.80 BC: From 14 plf at 0.00 to 14 plf at 7.03 BC: From 7 plf at 7.03 to 7 plf at 12.30 BC: From 14 plf at 12.30 to 14 plf at 19.33 TC: 254 lb Conc. Load at 7.03,12.30 TC: 186 lb Conc. Load at 9.06,10.27 BC: 442 lb Conc. Load at 7.03,12.30 BC: 111 lb Conc. Load at 9.06,10.27 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 7.00 12.33 BC 75 0.15 19.19 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1717 /- /- /- /825 /- E 1717 /- /- /- /825 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 2.0 E Brg Width = 3.5 Min Req = 2.0 Bearings B & E are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 -25 B - C 1490 -3081 C - D 1285 -2698 Chords Tens. Comp. D - E 1490 -3081 E - F 39 -25 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 2673 -1281 I - H 2698 -1285 Chords Tens. Comp. H - G 2698 -1285 G - E 2673 -1281 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - I 657 -88 Webs Tens. Comp. G - D 657 -88 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.157 G 999 360 VERT(CL): 0.315 G 725 240 HORZ(LL): 0.059 C - - HORZ(TL): 0.118 C - - Creep Factor: 2.0 Max TC CSI: 0.764 Max BC CSI: 0.999 Max Web CSI: 0.250 Weight: 75.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss B01 Truss Type HIPS Qty 1 Ply 1 Seal #: 2516 05/29/2021 19'4" 7'5'4"7' 1'5-9/16"1'5-9/16" 4-3/16"3'10-3/16"4'5-15/16"A B C D E FGHI 6 12 4X6(A2) 5X6 2X4 H0308 2X4 5X6 4X6(A2) 7'0-3/8" 442# 254# 2'0-3/8" 111# 186# 1'2-1/2" 111# 186# 2'0-3/8" 442# 254# 7'0-3/8" **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; T2 2x4 SP M-30; Bot chord: 2x4 SP M-30; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 62 plf at -1.46 to 62 plf at 7.00 TC: From 31 plf at 7.00 to 31 plf at 12.33 TC: From 62 plf at 12.33 to 62 plf at 20.80 BC: From 14 plf at 0.00 to 14 plf at 7.03 BC: From 7 plf at 7.03 to 7 plf at 12.30 BC: From 14 plf at 12.30 to 14 plf at 19.33 TC: 254 lb Conc. Load at 7.03,12.30 TC: 186 lb Conc. Load at 9.06,10.27 BC: 442 lb Conc. Load at 7.03,12.30 BC: 111 lb Conc. Load at 9.06,10.27 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 7.00 12.33 BC 75 0.15 19.19 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 1717 /- /- /- /825 /- E 1717 /- /- /- /825 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 2.0 E Brg Width = 3.5 Min Req = 2.0 Bearings B & E are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 -25 B - C 1490 -3081 C - D 1285 -2698 Chords Tens. Comp. D - E 1490 -3081 E - F 39 -25 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 2673 -1281 I - H 2698 -1285 Chords Tens. Comp. H - G 2698 -1285 G - E 2673 -1281 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - I 657 -88 Webs Tens. Comp. G - D 657 -88 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:10(0)/10(10) Plate Type(s): WAVE, HS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.157 G 999 360 VERT(CL): 0.315 G 725 240 HORZ(LL): 0.059 C - - HORZ(TL): 0.118 C - - Creep Factor: 2.0 Max TC CSI: 0.764 Max BC CSI: 0.999 Max Web CSI: 0.250 Weight: 75.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss B01 Truss Type HIPS Qty 1 Ply 1 Seal #: 2516 05/29/2021 19'4" 7'5'4"7' 1'5-9/16"1'5-9/16" 4-3/16"3'10-3/16"4'5-15/16"A B C D E FGHI 6 12 4X6(A2) 5X6 2X4 H0308 2X4 5X6 4X6(A2) 7'0-3/8" 442# 254# 2'0-3/8" 111# 186# 1'2-1/2" 111# 186# 2'0-3/8" 442# 254# 7'0-3/8" Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.00 10.33 BC 112 0.15 19.19 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 825 /- /- /475 /361 /161 H 825 /- /- /475 /361 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 H Brg Width = 3.5 Min Req = 1.5 Bearings B & H are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 637 -1161 C - D 539 -883 D - E 512 -742 Chords Tens. Comp. E - F 512 -742 F - G 539 -883 G - H 637 -1161 H - I 39 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 975 -429 Chords Tens. Comp. J - H 975 -433 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - J 279 -301 E - J 521 -240 Webs Tens. Comp. J - G 279 -301 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.039 J 999 360 VERT(CL): 0.073 J 999 240 HORZ(LL): 0.015 J - - HORZ(TL): 0.028 J - - Creep Factor: 2.0 Max TC CSI: 0.357 Max BC CSI: 0.984 Max Web CSI: 0.198 Weight: 85.4 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss B02 Truss Type HIPS Qty 1 Ply 1 Seal #: 2497 05/29/2021 19'4" 9'1'4"9' 1'5-9/16"1'5-9/16" 4-3/16"4'10-3/16"5'5-15/16"A B C D E F G H IJ 6 12 2X4(A1) 1.5X3 5X6 1.5X4 5X6 5X6 1.5X3 2X4(A1) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) TC 24 9.00 10.33 BC 112 0.15 19.19 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 825 /- /- /475 /361 /161 H 825 /- /- /475 /361 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 H Brg Width = 3.5 Min Req = 1.5 Bearings B & H are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 637 -1161 C - D 539 -883 D - E 512 -742 Chords Tens. Comp. E - F 512 -742 F - G 539 -883 G - H 637 -1161 H - I 39 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - J 975 -429 Chords Tens. Comp. J - H 975 -433 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - J 279 -301 E - J 521 -240 Webs Tens. Comp. J - G 279 -301 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.039 J 999 360 VERT(CL): 0.073 J 999 240 HORZ(LL): 0.015 J - - HORZ(TL): 0.028 J - - Creep Factor: 2.0 Max TC CSI: 0.357 Max BC CSI: 0.984 Max Web CSI: 0.198 Weight: 85.4 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss B02 Truss Type HIPS Qty 1 Ply 1 Seal #: 2497 05/29/2021 19'4" 9'1'4"9' 1'5-9/16"1'5-9/16" 4-3/16"4'10-3/16"5'5-15/16"A B C D E F G H IJ 6 12 2X4(A1) 1.5X3 5X6 1.5X4 5X6 5X6 1.5X3 2X4(A1) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x6 SP 2400f-2.0E; Webs: 2x4 SP #3; W3 2x4 SP #2; Nailnote Nail Schedule:0.131"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @ 3.50" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. (1) 1/2" bolts may be used for (2) 0.131"x3", min. nails on The Bottom Chord Only. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 62 plf at -1.46 to 62 plf at 7.06 TC: From 31 plf at 7.06 to 31 plf at 11.06 TC: From 62 plf at 11.06 to 62 plf at 19.33 BC: From 14 plf at 0.00 to 14 plf at 7.06 BC: From 7 plf at 7.06 to 7 plf at 19.33 BC: 2424 lb Conc. Load at 7.06 BC: 1010 lb Conc. Load at 9.06,11.06 BC: 1015 lb Conc. Load at 13.06,15.06,16.94,18.94 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.15 19.19 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 3926 /- /- /- /1685 /- F 5928 /- /- /- /1963 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.6 F Brg Width = 3.5 Min Req = 2.5 Bearings B & F are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 20 -13 B - C 1772 -4140 C - D 1342 -3260 Chords Tens. Comp. D - E 1346 -3267 E - F 1694 -4693 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 3669 -1564 I - H 3647 -1554 Chords Tens. Comp. H - G 4142 -1493 G - F 4179 -1501 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. I - C 689 -316 C - H 416 -849 D - H 2781 -1118 Webs Tens. Comp. H - E 347 -1409 E - G 1153 -229 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.122 H 999 360 VERT(CL): 0.225 H 999 240 HORZ(LL): 0.030 G - - HORZ(TL): 0.055 G - - Creep Factor: 2.0 Max TC CSI: 0.640 Max BC CSI: 0.789 Max Web CSI: 0.628 Weight: 215.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss B03 Truss Type COMN Qty 1 Ply 2 Seal #: 2518 05/29/2021 19'4" 9'8"9'8" 1'5-9/16" 4-3/16"5'2-3/16"5'9-15/16"A B C D E F GHI 6 12 3X10(A5R) 4X4 3X4 4X6(R) 8X8 4X4(R) 3X8 4X8(A8R) 7'0-3/4" 2424# 2' 1010# 2' 1010# 2' 1015# 2' 1015# 1'10-1/2" 1015# 2' 1015# 4-3/4" **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x6 SP 2400f-2.0E; Webs: 2x4 SP #3; W3 2x4 SP #2; Nailnote Nail Schedule:0.131"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @ 3.50" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. (1) 1/2" bolts may be used for (2) 0.131"x3", min. nails on The Bottom Chord Only. Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From 62 plf at -1.46 to 62 plf at 7.06 TC: From 31 plf at 7.06 to 31 plf at 11.06 TC: From 62 plf at 11.06 to 62 plf at 19.33 BC: From 14 plf at 0.00 to 14 plf at 7.06 BC: From 7 plf at 7.06 to 7 plf at 19.33 BC: 2424 lb Conc. Load at 7.06 BC: 1010 lb Conc. Load at 9.06,11.06 BC: 1015 lb Conc. Load at 13.06,15.06,16.94,18.94 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.15 19.19 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 3926 /- /- /- /1685 /- F 5928 /- /- /- /1963 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.6 F Brg Width = 3.5 Min Req = 2.5 Bearings B & F are a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 20 -13 B - C 1772 -4140 C - D 1342 -3260 Chords Tens. Comp. D - E 1346 -3267 E - F 1694 -4693 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - I 3669 -1564 I - H 3647 -1554 Chords Tens. Comp. H - G 4142 -1493 G - F 4179 -1501 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. I - C 689 -316 C - H 416 -849 D - H 2781 -1118 Webs Tens. Comp. H - E 347 -1409 E - G 1153 -229 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.122 H 999 360 VERT(CL): 0.225 H 999 240 HORZ(LL): 0.030 G - - HORZ(TL): 0.055 G - - Creep Factor: 2.0 Max TC CSI: 0.640 Max BC CSI: 0.789 Max Web CSI: 0.628 Weight: 215.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss B03 Truss Type COMN Qty 1 Ply 2 Seal #: 2518 05/29/2021 19'4" 9'8"9'8" 1'5-9/16" 4-3/16"5'2-3/16"5'9-15/16"A B C D E F GHI 6 12 3X10(A5R) 4X4 3X4 4X6(R) 8X8 4X4(R) 3X8 4X8(A8R) 7'0-3/4" 2424# 2' 1010# 2' 1010# 2' 1015# 2' 1015# 1'10-1/2" 1015# 2' 1015# 4-3/4" Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 :SP 2400f-2.0E + SP M-31:; T2 2x4 SP M-30; Bot chord: 2x6 SP 2400f-2.0E; B2 2x8 SP 2400f-1.8E; Webs: 2x4 SP #3; W1,W12 2x8 SP 2400f-1.8E; W2,W4, W11 2x4 SP #2; Bracing (a) Continuous lateral restraint equally spaced on member. Nailnote Nail Schedule:0.131"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @ 3.25" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. (1) 1/2" bolts may be used for (2) 0.131"x3", min. nails on The Bottom Chord Only. Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 46 plf at 0.00 to 46 plf at 17.56 BC: From 5 plf at 0.00 to 5 plf at 17.56 BC: 748 lb Conc. Load at 2.15, 4.15, 6.15, 8.15 10.15,12.15,14.15 BC: 691 lb Conc. Load at 15.00 BC: 946 lb Conc. Load at 16.04 Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.00 17.56 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL Y 3434 /- /- /- /- /- Z 4327 /- /- /- /- /- Y Brg Width = 6.9 Min Req = 1.5 Z Brg Width = 5.5 Min Req = 1.8 Bearings Y & Z are a rigid surface. Bearing Y requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -3112 B - C 0 -4857 C - D 0 -6498 D - E 0 -6498 E - F 0 -8081 F - G 0 -8627 Chords Tens. Comp. G - H 0 -8625 H - I 0 -8571 I - J 0 -6406 J - K 0 -6406 K - L 0 -6406 L - M 0 -228 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Y - X 131 0 X - W 3534 0 W - V 5187 0 V - U 7949 0 U - T 8081 0 T - S 8173 0 Chords Tens. Comp. S - R 8592 0 R - Q 8091 0 Q - P 8091 0 P - O 4323 0 O - N 4323 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - Y 0 -1528 A - X 3311 0 X - B 0 -1449 B - W 1955 0 W - C 0 -1136 C - V 1640 0 V - E 0 -1810 D - V 98 0 E - U 876 0 T - F 0 -506 F - S 764 0 Webs Tens. Comp. G - S 0 -18 S - H 40 0 H - R 0 -90 R - I 544 0 I - Q 491 0 I - P 0 -1880 J - P 0 -11 P - L 2323 0 L - O 591 0 L - N 0 -4400 M - N 0 -96 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 22.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:10(0)/10(10) Plate Type(s): WAVE, 18SS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.490 G 430 360 VERT(CL): 0.674 G 312 240 HORZ(LL): 0.071 A - - HORZ(TL): 0.098 A - - Creep Factor: 2.0 Max TC CSI: 0.935 Max BC CSI: 0.995 Max Web CSI: 0.997 Weight: 228.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FG02 Truss Type FLAT Qty 1 Ply 2 Seal #: 2564 05/29/2021 17'6-3/4" SEAT PLATE REQ. 17'6-3/4"1'4"(a)A B C D E F G H I J K L M NOPQRSTUVWXYZ 6X8 4X4 4X10 5X6 5X6 4X6 4X12 4X6 3X6 3X4 SS1012 3X4 3X4 4X10 3X4 6X10 3X6 5X14 4X4 3X3 6X8 2'1-3/4" 748# 2' 748# 2' 748# 2' 748# 2' 748# 2' 748# 2' 748# 10-1/4" 691# 1'0-1/2" 946# 1'6-1/4" **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 :SP 2400f-2.0E + SP M-31:; T2 2x4 SP M-30; Bot chord: 2x6 SP 2400f-2.0E; B2 2x8 SP 2400f-1.8E; Webs: 2x4 SP #3; W1,W12 2x8 SP 2400f-1.8E; W2,W4, W11 2x4 SP #2; Bracing (a) Continuous lateral restraint equally spaced on member. Nailnote Nail Schedule:0.131"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @ 3.25" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. (1) 1/2" bolts may be used for (2) 0.131"x3", min. nails on The Bottom Chord Only. Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 46 plf at 0.00 to 46 plf at 17.56 BC: From 5 plf at 0.00 to 5 plf at 17.56 BC: 748 lb Conc. Load at 2.15, 4.15, 6.15, 8.15 10.15,12.15,14.15 BC: 691 lb Conc. Load at 15.00 BC: 946 lb Conc. Load at 16.04 Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.00 17.56 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL Y 3434 /- /- /- /- /- Z 4327 /- /- /- /- /- Y Brg Width = 6.9 Min Req = 1.5 Z Brg Width = 5.5 Min Req = 1.8 Bearings Y & Z are a rigid surface. Bearing Y requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -3112 B - C 0 -4857 C - D 0 -6498 D - E 0 -6498 E - F 0 -8081 F - G 0 -8627 Chords Tens. Comp. G - H 0 -8625 H - I 0 -8571 I - J 0 -6406 J - K 0 -6406 K - L 0 -6406 L - M 0 -228 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. Y - X 131 0 X - W 3534 0 W - V 5187 0 V - U 7949 0 U - T 8081 0 T - S 8173 0 Chords Tens. Comp. S - R 8592 0 R - Q 8091 0 Q - P 8091 0 P - O 4323 0 O - N 4323 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - Y 0 -1528 A - X 3311 0 X - B 0 -1449 B - W 1955 0 W - C 0 -1136 C - V 1640 0 V - E 0 -1810 D - V 98 0 E - U 876 0 T - F 0 -506 F - S 764 0 Webs Tens. Comp. G - S 0 -18 S - H 40 0 H - R 0 -90 R - I 544 0 I - Q 491 0 I - P 0 -1880 J - P 0 -11 P - L 2323 0 L - O 591 0 L - N 0 -4400 M - N 0 -96 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 22.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:10(0)/10(10) Plate Type(s): WAVE, 18SS Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.490 G 430 360 VERT(CL): 0.674 G 312 240 HORZ(LL): 0.071 A - - HORZ(TL): 0.098 A - - Creep Factor: 2.0 Max TC CSI: 0.935 Max BC CSI: 0.995 Max Web CSI: 0.997 Weight: 228.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FG02 Truss Type FLAT Qty 1 Ply 2 Seal #: 2564 05/29/2021 17'6-3/4" SEAT PLATE REQ. 17'6-3/4"1'4"(a)A B C D E F G H I J K L M NOPQRSTUVWXYZ 6X8 4X4 4X10 5X6 5X6 4X6 4X12 4X6 3X6 3X4 SS1012 3X4 3X4 4X10 3X4 6X10 3X6 5X14 4X4 3X3 6X8 2'1-3/4" 748# 2' 748# 2' 748# 2' 748# 2' 748# 2' 748# 2' 748# 10-1/4" 691# 1'0-1/2" 946# 1'6-1/4" Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x6 SP #2; Webs: 2x6 SP #2; W2 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 3.45 BC: From 10 plf at 0.00 to 10 plf at 3.45 BC: 822 lb Conc. Load at 2.10 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 41 0.00 3.45 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Hangers / Ties (J) Hanger Support Required, by others Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL D 510 /- /- /- /- /- C 691 /- /- /- /- /- D Brg Width = 3.5 Min Req = 1.5 C Brg Width = - Min Req = - Bearing D is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -105 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. D - C 98 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - D 0 -175 A - C 8 0 Webs Tens. Comp. B - C 0 -172 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 A 999 360 VERT(CL): 0.000 A 999 240 HORZ(LL): 0.000 C - - HORZ(TL): 0.000 C - - Creep Factor: 2.0 Max TC CSI: 0.348 Max BC CSI: 0.965 Max Web CSI: 0.072 Weight: 22.4 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FG03 Truss Type FLAT Qty 1 Ply 1 Seal #: 2551 05/29/2021 3'5-3/8"1'3-3/4"A B CD 3X4 1.5X4 1.5X4 4X4 2'1-1/4" 822# 1'4-1/8" **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x6 SP #2; Webs: 2x6 SP #2; W2 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 3.45 BC: From 10 plf at 0.00 to 10 plf at 3.45 BC: 822 lb Conc. Load at 2.10 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 41 0.00 3.45 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Hangers / Ties (J) Hanger Support Required, by others Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL D 510 /- /- /- /- /- C 691 /- /- /- /- /- D Brg Width = 3.5 Min Req = 1.5 C Brg Width = - Min Req = - Bearing D is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -105 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. D - C 98 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - D 0 -175 A - C 8 0 Webs Tens. Comp. B - C 0 -172 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 A 999 360 VERT(CL): 0.000 A 999 240 HORZ(LL): 0.000 C - - HORZ(TL): 0.000 C - - Creep Factor: 2.0 Max TC CSI: 0.348 Max BC CSI: 0.965 Max Web CSI: 0.072 Weight: 22.4 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FG03 Truss Type FLAT Qty 1 Ply 1 Seal #: 2551 05/29/2021 3'5-3/8"1'3-3/4"A B CD 3X4 1.5X4 1.5X4 4X4 2'1-1/4" 822# 1'4-1/8" Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP M-30; B2 2x6 SP #2; Webs: 2x4 SP #3; W1,W8 2x6 SP #2; W7 2x4 SP #2; Nailnote Nail Schedule:0.131"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @11.00" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 15.94 BC: From 10 plf at 0.00 to 10 plf at 15.94 BC: 1784 lb Conc. Load at 13.69 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.12 16.06 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL N 1128 /- /- /- /- /- H 2409 /- /- /- /- /- N Brg Width = 6.9 Min Req = 1.5 H Brg Width = 3.5 Min Req = 1.5 Bearings N & H are a rigid surface. Bearing N requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -1447 B - C 0 -2567 C - D 0 -2600 Chords Tens. Comp. D - E 0 -2600 E - F 0 -2592 F - G 0 -2877 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. N - M 53 0 M - L 1584 0 L - K 2600 0 Chords Tens. Comp. K - J 2898 0 J - I 2898 0 I - H 128 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - N 0 -534 A - M 1462 0 M - B 0 -496 B - L 1042 0 L - C 0 -234 Webs Tens. Comp. E - K 0 -61 K - F 0 -323 F - I 0 -61 I - G 2858 0 G - H 0 -891 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.239 E 801 360 VERT(CL): 0.328 E 583 240 HORZ(LL): 0.027 A - - HORZ(TL): 0.037 A - - Creep Factor: 2.0 Max TC CSI: 0.551 Max BC CSI: 0.943 Max Web CSI: 0.807 Weight: 156.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FG05 Truss Type FLAT Qty 1 Ply 2 Seal #: 2554 05/29/2021 16'0-3/4" SEAT PLATE REQ. 16'0-3/4" 15'11-1/4" 1'3-3/4" A B C D E F G HIJKLMN 3X10 1.5X4 4X6(R) 4X4 4X4 1.5X3 3X4 1.5X3 3X4 4X6 3X4 6X6 6X6 3X4 13'9-3/4" 1784# 2'3" **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP M-30; B2 2x6 SP #2; Webs: 2x4 SP #3; W1,W8 2x6 SP #2; W7 2x4 SP #2; Nailnote Nail Schedule:0.131"x3", min. nails Top Chord: 1 Row @12.00" o.c. Bot Chord: 1 Row @11.00" o.c. Webs : 1 Row @ 4" o.c. Use equal spacing between rows and stagger nails in each row to avoid splitting. Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 100 plf at 0.00 to 100 plf at 15.94 BC: From 10 plf at 0.00 to 10 plf at 15.94 BC: 1784 lb Conc. Load at 13.69 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.12 16.06 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. The TC of this truss shall be braced with attached spans at 24" oc in lieu of structural sheathing. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL N 1128 /- /- /- /- /- H 2409 /- /- /- /- /- N Brg Width = 6.9 Min Req = 1.5 H Brg Width = 3.5 Min Req = 1.5 Bearings N & H are a rigid surface. Bearing N requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -1447 B - C 0 -2567 C - D 0 -2600 Chords Tens. Comp. D - E 0 -2600 E - F 0 -2592 F - G 0 -2877 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. N - M 53 0 M - L 1584 0 L - K 2600 0 Chords Tens. Comp. K - J 2898 0 J - I 2898 0 I - H 128 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - N 0 -534 A - M 1462 0 M - B 0 -496 B - L 1042 0 L - C 0 -234 Webs Tens. Comp. E - K 0 -61 K - F 0 -323 F - I 0 -61 I - G 2858 0 G - H 0 -891 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.239 E 801 360 VERT(CL): 0.328 E 583 240 HORZ(LL): 0.027 A - - HORZ(TL): 0.037 A - - Creep Factor: 2.0 Max TC CSI: 0.551 Max BC CSI: 0.943 Max Web CSI: 0.807 Weight: 156.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FG05 Truss Type FLAT Qty 1 Ply 2 Seal #: 2554 05/29/2021 16'0-3/4" SEAT PLATE REQ. 16'0-3/4" 15'11-1/4" 1'3-3/4" A B C D E F G HIJKLMN 3X10 1.5X4 4X6(R) 4X4 4X4 1.5X3 3X4 1.5X3 3X4 4X6 3X4 6X6 6X6 3X4 13'9-3/4" 1784# 2'3" Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP M-30; Bot chord: 4x2 SP M-30; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 18.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Deflection Max JT VERT DEFL: LL: 0.41" DL: 0.21". See detail DEFLCAMB1014 for camber recommendations. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL P 1043 /- /- /- /- /- K 1043 /- /- /- /- /- P Brg Width = 6.9 Min Req = 1.5 K Brg Width = 6.9 Min Req = 1.5 Bearings P & K are a rigid surface. Bearings P & K require a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -3191 C - D 0 -3191 D - E 0 -3918 Chords Tens. Comp. E - F 0 -3922 F - G 0 -3175 G - H 0 -3175 H - I 1 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. P - O 1872 0 O - N 3846 0 N - M 3922 0 Chords Tens. Comp. M - L 3919 0 L - K 1869 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. Q - R 0 -4 A - P 0 -110 P - B 0 -2079 B - O 1458 0 C - O 0 -253 O - D 0 -725 D - N 483 -229 N - E 77 -247 Webs Tens. Comp. M - F 137 -58 F - L 0 -1030 G - L 26 -285 L - H 1444 0 H - K 0 -2077 I - K 0 -111 J - S 0 -4 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.416 E 540 360 VERT(CL): 0.531 E 423 240 HORZ(LL): 0.052 B - - HORZ(TL): 0.072 B - - Creep Factor: 2.0 Max TC CSI: 0.510 Max BC CSI: 0.823 Max Web CSI: 0.694 Weight: 103.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL01 Truss Type SY42 Qty 9 Ply 1 Seal #: 2537 05/29/2021 9'1-1/2"11'2-1/2"19'2-1/2" 3-5/8" 3-5/8"1'4"3-5/8" 3-5/8" 1'11-1/2" 2'6" (TYP) 19'2-1/2" SEAT PLATE REQ.SEAT PLATE REQ. + A B C D E F G H I J KLMNOP Q R S 1.5X3(R) 1.5X3(R) 1.5X3 3X6 3X10 1.5X3 3X10 3X4 3X3 1.5X3 1.5X3 3X4 1.5X3 3X10 3X10 1.5X3 3X6 1.5X3(R) 1.5X3(R) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP M-30; Bot chord: 4x2 SP M-30; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 18.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Deflection Max JT VERT DEFL: LL: 0.41" DL: 0.21". See detail DEFLCAMB1014 for camber recommendations. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL P 1043 /- /- /- /- /- K 1043 /- /- /- /- /- P Brg Width = 6.9 Min Req = 1.5 K Brg Width = 6.9 Min Req = 1.5 Bearings P & K are a rigid surface. Bearings P & K require a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -3191 C - D 0 -3191 D - E 0 -3918 Chords Tens. Comp. E - F 0 -3922 F - G 0 -3175 G - H 0 -3175 H - I 1 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. P - O 1872 0 O - N 3846 0 N - M 3922 0 Chords Tens. Comp. M - L 3919 0 L - K 1869 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. Q - R 0 -4 A - P 0 -110 P - B 0 -2079 B - O 1458 0 C - O 0 -253 O - D 0 -725 D - N 483 -229 N - E 77 -247 Webs Tens. Comp. M - F 137 -58 F - L 0 -1030 G - L 26 -285 L - H 1444 0 H - K 0 -2077 I - K 0 -111 J - S 0 -4 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.416 E 540 360 VERT(CL): 0.531 E 423 240 HORZ(LL): 0.052 B - - HORZ(TL): 0.072 B - - Creep Factor: 2.0 Max TC CSI: 0.510 Max BC CSI: 0.823 Max Web CSI: 0.694 Weight: 103.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL01 Truss Type SY42 Qty 9 Ply 1 Seal #: 2537 05/29/2021 9'1-1/2"11'2-1/2"19'2-1/2" 3-5/8" 3-5/8"1'4"3-5/8" 3-5/8" 1'11-1/2" 2'6" (TYP) 19'2-1/2" SEAT PLATE REQ.SEAT PLATE REQ. + A B C D E F G H I J KLMNOP Q R S 1.5X3(R) 1.5X3(R) 1.5X3 3X6 3X10 1.5X3 3X10 3X4 3X3 1.5X3 1.5X3 3X4 1.5X3 3X10 3X10 1.5X3 3X6 1.5X3(R) 1.5X3(R) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 18.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL AE*108 /- /- /- /- /- Q 74 /- /- /- /- /- AE Brg Width = 223 Min Req = - Q Brg Width = 6.9 Min Req = 1.5 Bearings AE & Q are a rigid surface. Bearings AE & Q require a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 8 0 C - D 2 0 D - E 2 0 E - F 2 0 F - G 2 0 G - H 2 0 Chords Tens. Comp. H - I 2 0 I - J 2 0 J - K 2 0 K - L 2 0 L - M 2 0 M - N 8 0 N - O 1 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AE-AD 0 -1 AD-AC 4 0 AC-AB 0 -2 AB-AA 0 -2 AA- Z 0 -2 Z - Y 0 -2 Y - X 0 -2 Chords Tens. Comp. X - W 0 -2 W - V 0 -2 V - U 0 -2 U - T 0 -2 T - S 0 -2 S - R 4 0 R - Q 0 -1 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AF-AG 0 -3 A -AE 0 -64 AD- C 0 -17 Webs Tens. Comp. M - R 0 -17 O - Q 0 -64 P -AH 0 -3 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. B -AD 0 -148 C -AC 0 -117 D -AB 0 -139 E -AA 0 -132 F - Z 0 -134 G - Y 0 -133 H - X 0 -133 Gables Tens. Comp. I - W 0 -133 J - V 0 -134 K - U 0 -132 L - T 0 -139 S - M 0 -117 R - N 0 -148 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 O 999 360 VERT(CL): 0.001 O 999 240 HORZ(LL): -0.000 B - - HORZ(TL): 0.000 B - - Creep Factor: 2.0 Max TC CSI: 0.117 Max BC CSI: 0.011 Max Web CSI: 0.034 Weight: 106.4 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL01GE Truss Type SY42 Qty 1 Ply 1 Seal #: 2538 05/29/2021 1'6-1/2" 2'10-1/2"17'6-1/2"19'2-1/2" 3-5/8" 3-5/8"1'4"3-5/8" 3-5/8" 1'4" (TYP) 19'2-1/2" SEAT PLATE REQ.SEAT PLATE REQ. A B C D E F G H I J K L M N O P Q RSTUVWXYZAAABACADAE AF AG AH 1.5X3(R) 1.5X3(R) 3X3 3X3 3X3 3X3 1.5X3(R) 1.5X3(R) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 18.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL AE*108 /- /- /- /- /- Q 74 /- /- /- /- /- AE Brg Width = 223 Min Req = - Q Brg Width = 6.9 Min Req = 1.5 Bearings AE & Q are a rigid surface. Bearings AE & Q require a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 8 0 C - D 2 0 D - E 2 0 E - F 2 0 F - G 2 0 G - H 2 0 Chords Tens. Comp. H - I 2 0 I - J 2 0 J - K 2 0 K - L 2 0 L - M 2 0 M - N 8 0 N - O 1 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AE-AD 0 -1 AD-AC 4 0 AC-AB 0 -2 AB-AA 0 -2 AA- Z 0 -2 Z - Y 0 -2 Y - X 0 -2 Chords Tens. Comp. X - W 0 -2 W - V 0 -2 V - U 0 -2 U - T 0 -2 T - S 0 -2 S - R 4 0 R - Q 0 -1 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AF-AG 0 -3 A -AE 0 -64 AD- C 0 -17 Webs Tens. Comp. M - R 0 -17 O - Q 0 -64 P -AH 0 -3 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. B -AD 0 -148 C -AC 0 -117 D -AB 0 -139 E -AA 0 -132 F - Z 0 -134 G - Y 0 -133 H - X 0 -133 Gables Tens. Comp. I - W 0 -133 J - V 0 -134 K - U 0 -132 L - T 0 -139 S - M 0 -117 R - N 0 -148 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 O 999 360 VERT(CL): 0.001 O 999 240 HORZ(LL): -0.000 B - - HORZ(TL): 0.000 B - - Creep Factor: 2.0 Max TC CSI: 0.117 Max BC CSI: 0.011 Max Web CSI: 0.034 Weight: 106.4 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL01GE Truss Type SY42 Qty 1 Ply 1 Seal #: 2538 05/29/2021 1'6-1/2" 2'10-1/2"17'6-1/2"19'2-1/2" 3-5/8" 3-5/8"1'4"3-5/8" 3-5/8" 1'4" (TYP) 19'2-1/2" SEAT PLATE REQ.SEAT PLATE REQ. A B C D E F G H I J K L M N O P Q RSTUVWXYZAAABACADAE AF AG AH 1.5X3(R) 1.5X3(R) 3X3 3X3 3X3 3X3 1.5X3(R) 1.5X3(R) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP M-30; Bot chord: 4x2 SP M-30; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 13.35 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL L 734 /- /- /- /- /- H 748 /- /- /- /- /- L Brg Width = 6.9 Min Req = 1.5 H Brg Width = - Min Req = - Bearing L is a rigid surface. Bearing L requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -1897 C - D 0 -1897 Chords Tens. Comp. D - E 0 -1814 E - F 0 -1795 F - G 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. L - K 1238 0 K - J 1820 0 Chords Tens. Comp. J - I 1814 0 I - H 1244 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - N 0 -4 A - L 0 -109 L - B 0 -1376 B - K 729 0 C - K 0 -291 K - D 258 -251 Webs Tens. Comp. D - J 0 -166 E - I 0 -393 I - F 809 0 F - H 0 -1385 H - G 0 -15 G - H 0 -129 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.228 J 690 360 VERT(CL): 0.335 J 469 240 HORZ(LL): 0.035 B - - HORZ(TL): 0.054 B - - Creep Factor: 2.0 Max TC CSI: 0.765 Max BC CSI: 0.726 Max Web CSI: 0.385 Weight: 75.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL02 Truss Type SY42 Qty 11 Ply 1 Seal #: 2539 05/29/2021 6'9"9'4-1/4"13'7-1/4" 3-5/8" 3-5/8"1'4"2'5-3/4" 2'6" (TYP) 13'7-1/4" SEAT PLATE REQ. A B C D E F G HIJKL M N 1.5X3(R) 1.5X3(R) 1.5X3 3X4 3X6 1.5X3 3X6 3X3 1.5X3 1.5X3 3X4 3X6 2X4 3X6 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP M-30; Bot chord: 4x2 SP M-30; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 13.35 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL L 734 /- /- /- /- /- H 748 /- /- /- /- /- L Brg Width = 6.9 Min Req = 1.5 H Brg Width = - Min Req = - Bearing L is a rigid surface. Bearing L requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -1897 C - D 0 -1897 Chords Tens. Comp. D - E 0 -1814 E - F 0 -1795 F - G 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. L - K 1238 0 K - J 1820 0 Chords Tens. Comp. J - I 1814 0 I - H 1244 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - N 0 -4 A - L 0 -109 L - B 0 -1376 B - K 729 0 C - K 0 -291 K - D 258 -251 Webs Tens. Comp. D - J 0 -166 E - I 0 -393 I - F 809 0 F - H 0 -1385 H - G 0 -15 G - H 0 -129 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.228 J 690 360 VERT(CL): 0.335 J 469 240 HORZ(LL): 0.035 B - - HORZ(TL): 0.054 B - - Creep Factor: 2.0 Max TC CSI: 0.765 Max BC CSI: 0.726 Max Web CSI: 0.385 Weight: 75.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL02 Truss Type SY42 Qty 11 Ply 1 Seal #: 2539 05/29/2021 6'9"9'4-1/4"13'7-1/4" 3-5/8" 3-5/8"1'4"2'5-3/4" 2'6" (TYP) 13'7-1/4" SEAT PLATE REQ. A B C D E F G HIJKL M N 1.5X3(R) 1.5X3(R) 1.5X3 3X4 3X6 1.5X3 3X6 3X3 1.5X3 1.5X3 3X4 3X6 2X4 3X6 Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 13.35 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL V 67 /- /- /- /- /- L* 109 /- /- /- /- /- V Brg Width = 6.9 Min Req = 1.5 L Brg Width = 156 Min Req = - Bearings V & V are a rigid surface. Bearings V & V require a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 8 0 C - D 3 0 D - E 3 0 E - F 3 0 Chords Tens. Comp. F - G 3 0 G - H 3 0 H - I 3 0 I - J 3 0 J - K 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. V - U 0 -1 U - T 3 0 T - S 0 -3 S - R 0 -3 R - Q 0 -3 Chords Tens. Comp. Q - P 0 -3 P - O 0 -3 O - N 0 -3 N - M 0 -3 M - L 0 -3 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. W - X 0 -3 A - V 0 -58 U - C 0 -16 Webs Tens. Comp. L - K 0 -15 K - L 0 -60 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. B - U 0 -138 C - T 0 -121 D - S 0 -138 E - R 0 -132 F - Q 0 -134 Gables Tens. Comp. G - P 0 -133 H - O 0 -134 I - N 0 -132 J - M 0 -143 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 K 999 360 VERT(CL): 0.001 K 999 240 HORZ(LL): -0.000 L - - HORZ(TL): 0.000 L - - Creep Factor: 2.0 Max TC CSI: 0.107 Max BC CSI: 0.010 Max Web CSI: 0.033 Weight: 77.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL02GE Truss Type SY42 Qty 1 Ply 1 Seal #: 2540 05/29/2021 1'4-7/8" 2'8-7/8"12'0-7/8"13'7-1/4" 3-5/8" 3-5/8"1'4"1'4" (TYP) 13'7-1/4" SEAT PLATE REQ.SEAT PLATE REQ. A B C D E F G H I J K L MNOPQRSTU V W X 1.5X3(R) 1.5X3(R) 3X3 3X3 2X4 2X4(R) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 13.35 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL V 67 /- /- /- /- /- L* 109 /- /- /- /- /- V Brg Width = 6.9 Min Req = 1.5 L Brg Width = 156 Min Req = - Bearings V & V are a rigid surface. Bearings V & V require a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 8 0 C - D 3 0 D - E 3 0 E - F 3 0 Chords Tens. Comp. F - G 3 0 G - H 3 0 H - I 3 0 I - J 3 0 J - K 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. V - U 0 -1 U - T 3 0 T - S 0 -3 S - R 0 -3 R - Q 0 -3 Chords Tens. Comp. Q - P 0 -3 P - O 0 -3 O - N 0 -3 N - M 0 -3 M - L 0 -3 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. W - X 0 -3 A - V 0 -58 U - C 0 -16 Webs Tens. Comp. L - K 0 -15 K - L 0 -60 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. B - U 0 -138 C - T 0 -121 D - S 0 -138 E - R 0 -132 F - Q 0 -134 Gables Tens. Comp. G - P 0 -133 H - O 0 -134 I - N 0 -132 J - M 0 -143 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 K 999 360 VERT(CL): 0.001 K 999 240 HORZ(LL): -0.000 L - - HORZ(TL): 0.000 L - - Creep Factor: 2.0 Max TC CSI: 0.107 Max BC CSI: 0.010 Max Web CSI: 0.033 Weight: 77.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL02GE Truss Type SY42 Qty 1 Ply 1 Seal #: 2540 05/29/2021 1'4-7/8" 2'8-7/8"12'0-7/8"13'7-1/4" 3-5/8" 3-5/8"1'4"1'4" (TYP) 13'7-1/4" SEAT PLATE REQ.SEAT PLATE REQ. A B C D E F G H I J K L MNOPQRSTU V W X 1.5X3(R) 1.5X3(R) 3X3 3X3 2X4 2X4(R) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP M-30; Bot chord: 4x2 SP M-30; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 13.65 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL L 750 /- /- /- /- /- H 764 /- /- /- /- /- L Brg Width = 6.9 Min Req = 1.5 H Brg Width = 3.5 Min Req = 1.5 Bearings L & H are a rigid surface. Bearing L requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -1962 C - D 0 -1962 Chords Tens. Comp. D - E 0 -1917 E - F 0 -1899 F - G 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. L - K 1271 0 K - J 1923 0 Chords Tens. Comp. J - I 1917 0 I - H 1271 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - N 0 -4 A - L 0 -109 L - B 0 -1413 B - K 764 0 C - K 7 -286 K - D 231 -295 Webs Tens. Comp. D - J 7 -162 E - I 0 -357 I - F 841 0 F - H 0 -1414 H - G 0 -15 G - H 0 -128 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.225 J 715 360 VERT(CL): 0.335 J 479 240 HORZ(LL): 0.034 B - - HORZ(TL): 0.054 B - - Creep Factor: 2.0 Max TC CSI: 0.708 Max BC CSI: 0.726 Max Web CSI: 0.401 Weight: 75.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL03 Truss Type SY42 Qty 2 Ply 1 Seal #: 2541 05/29/2021 6'9"9'4-1/4"13'10-3/4" 3-5/8" 3-5/8"1'4"2'5-3/4" 2'6" (TYP) 13'10-3/4" SEAT PLATE REQ. A B C D E F G HIJKL M N 1.5X3(R) 1.5X3(R) 1.5X3 3X6 3X6 1.5X3 3X6 3X3 1.5X3 1.5X3 3X4 3X6 2X4 3X6 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP M-30; Bot chord: 4x2 SP M-30; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 13.65 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL L 750 /- /- /- /- /- H 764 /- /- /- /- /- L Brg Width = 6.9 Min Req = 1.5 H Brg Width = 3.5 Min Req = 1.5 Bearings L & H are a rigid surface. Bearing L requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -1962 C - D 0 -1962 Chords Tens. Comp. D - E 0 -1917 E - F 0 -1899 F - G 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. L - K 1271 0 K - J 1923 0 Chords Tens. Comp. J - I 1917 0 I - H 1271 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. M - N 0 -4 A - L 0 -109 L - B 0 -1413 B - K 764 0 C - K 7 -286 K - D 231 -295 Webs Tens. Comp. D - J 7 -162 E - I 0 -357 I - F 841 0 F - H 0 -1414 H - G 0 -15 G - H 0 -128 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.225 J 715 360 VERT(CL): 0.335 J 479 240 HORZ(LL): 0.034 B - - HORZ(TL): 0.054 B - - Creep Factor: 2.0 Max TC CSI: 0.708 Max BC CSI: 0.726 Max Web CSI: 0.401 Weight: 75.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL03 Truss Type SY42 Qty 2 Ply 1 Seal #: 2541 05/29/2021 6'9"9'4-1/4"13'10-3/4" 3-5/8" 3-5/8"1'4"2'5-3/4" 2'6" (TYP) 13'10-3/4" SEAT PLATE REQ. A B C D E F G HIJKL M N 1.5X3(R) 1.5X3(R) 1.5X3 3X6 3X6 1.5X3 3X6 3X3 1.5X3 1.5X3 3X4 3X6 2X4 3X6 Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP M-30; Bot chord: 4x2 SP M-30; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 15.81 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL N 870 /- /- /- /- /- I 884 /- /- /- /- /- N Brg Width = 6.9 Min Req = 1.5 I Brg Width = 3.5 Min Req = 1.5 Bearings N & I are a rigid surface. Bearing N requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -2441 C - D 0 -2441 D - E 0 -2700 Chords Tens. Comp. E - F 0 -2437 F - G 0 -2437 G - H 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. N - M 1517 0 M - L 2700 0 L - K 2700 0 Chords Tens. Comp. K - J 2699 0 J - I 1515 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. O - P 0 -4 A - N 0 -108 N - B 0 -1685 B - M 1022 0 C - M 62 -230 M - D 0 -604 D - L 111 -108 Webs Tens. Comp. K - E 129 -105 E - J 0 -627 F - J 84 -218 J - G 1019 0 G - I 0 -1686 I - H 0 -15 H - I 0 -112 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.212 L 879 360 VERT(CL): 0.300 L 621 240 HORZ(LL): 0.029 I - - HORZ(TL): 0.045 B - - Creep Factor: 2.0 Max TC CSI: 0.487 Max BC CSI: 0.635 Max Web CSI: 0.487 Weight: 88.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL05 Truss Type SY42 Qty 2 Ply 1 Seal #: 2542 05/29/2021 6'9"9'4-1/4"16'0-3/4" 3-5/8" 3-5/8"1'4"2'5-3/4" 2'6" (TYP) 16'0-3/4" SEAT PLATE REQ. + A B C D E F G H IJKLMN O P 1.5X3(R) 1.5X3(R) 1.5X3 3X6 4X6 1.5X3 3X8 3X3 1.5X3 1.5X3 3X3 1.5X3 3X8 4X6 2X4 4X6 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP M-30; Bot chord: 4x2 SP M-30; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 15.81 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL N 870 /- /- /- /- /- I 884 /- /- /- /- /- N Brg Width = 6.9 Min Req = 1.5 I Brg Width = 3.5 Min Req = 1.5 Bearings N & I are a rigid surface. Bearing N requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -2441 C - D 0 -2441 D - E 0 -2700 Chords Tens. Comp. E - F 0 -2437 F - G 0 -2437 G - H 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. N - M 1517 0 M - L 2700 0 L - K 2700 0 Chords Tens. Comp. K - J 2699 0 J - I 1515 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. O - P 0 -4 A - N 0 -108 N - B 0 -1685 B - M 1022 0 C - M 62 -230 M - D 0 -604 D - L 111 -108 Webs Tens. Comp. K - E 129 -105 E - J 0 -627 F - J 84 -218 J - G 1019 0 G - I 0 -1686 I - H 0 -15 H - I 0 -112 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.212 L 879 360 VERT(CL): 0.300 L 621 240 HORZ(LL): 0.029 I - - HORZ(TL): 0.045 B - - Creep Factor: 2.0 Max TC CSI: 0.487 Max BC CSI: 0.635 Max Web CSI: 0.487 Weight: 88.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL05 Truss Type SY42 Qty 2 Ply 1 Seal #: 2542 05/29/2021 6'9"9'4-1/4"16'0-3/4" 3-5/8" 3-5/8"1'4"2'5-3/4" 2'6" (TYP) 16'0-3/4" SEAT PLATE REQ. + A B C D E F G H IJKLMN O P 1.5X3(R) 1.5X3(R) 1.5X3 3X6 4X6 1.5X3 3X8 3X3 1.5X3 1.5X3 3X3 1.5X3 3X8 4X6 2X4 4X6 Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Bracing Sheathing is required for any longitudinal(drag) forces. All connections to be designed by the building designer. Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 15.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL O* 108 /- /- /- /- /- O Brg Width = 192 Min Req = - Bearing AA is a rigid surface. Bearing AA requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 7 0 C - D 0 0 D - E 0 0 E - F 0 0 F - G 0 0 Chords Tens. Comp. G - H 0 0 H - I 0 0 I - J 0 0 J - K 0 0 K - L 0 0 L - M 0 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AA- Z 0 -1 Z - Y 6 0 Y - X 0 0 X - W 0 0 W - V 0 0 V - U 0 0 Chords Tens. Comp. U - T 0 0 T - S 0 0 S - R 0 0 R - Q 0 0 Q - P 0 0 P - O 0 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AB-AC 0 -3 A -AA 0 -53 Z - C 0 -19 Webs Tens. Comp. M - N 0 -46 O - N 0 -3 N - O 0 -51 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. B - Z 0 -131 C - Y 0 -120 D - X 0 -138 E - W 0 -132 F - V 0 -134 G - U 0 -133 Gables Tens. Comp. H - T 0 -133 I - S 0 -133 J - R 0 -134 K - Q 0 -132 L - P 0 -140 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 M 999 360 VERT(CL): 0.000 M 999 240 HORZ(LL): -0.000 B - - HORZ(TL): 0.000 B - - Creep Factor: 2.0 Max TC CSI: 0.101 Max BC CSI: 0.009 Max Web CSI: 0.032 Weight: 86.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL05GE Truss Type SY42 Qty 1 Ply 1 Seal #: 2543 05/29/2021 1'3-5/8" 2'7-5/8"14'7-5/8"16'0-3/4" 3-5/8" 3-5/8"1'4"3-5/8" 1'4" (TYP) 16'0-3/4" SEAT PLATE REQ. A B C D E F G H I J K L M N O PQRSTUVWXYZAA AB AC 1.5X3(R) 1.5X3(R) 3X3 3X3 2X4(R) 1.5X3(R) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Bracing Sheathing is required for any longitudinal(drag) forces. All connections to be designed by the building designer. Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 15.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL O* 108 /- /- /- /- /- O Brg Width = 192 Min Req = - Bearing AA is a rigid surface. Bearing AA requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 7 0 C - D 0 0 D - E 0 0 E - F 0 0 F - G 0 0 Chords Tens. Comp. G - H 0 0 H - I 0 0 I - J 0 0 J - K 0 0 K - L 0 0 L - M 0 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AA- Z 0 -1 Z - Y 6 0 Y - X 0 0 X - W 0 0 W - V 0 0 V - U 0 0 Chords Tens. Comp. U - T 0 0 T - S 0 0 S - R 0 0 R - Q 0 0 Q - P 0 0 P - O 0 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AB-AC 0 -3 A -AA 0 -53 Z - C 0 -19 Webs Tens. Comp. M - N 0 -46 O - N 0 -3 N - O 0 -51 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. B - Z 0 -131 C - Y 0 -120 D - X 0 -138 E - W 0 -132 F - V 0 -134 G - U 0 -133 Gables Tens. Comp. H - T 0 -133 I - S 0 -133 J - R 0 -134 K - Q 0 -132 L - P 0 -140 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 M 999 360 VERT(CL): 0.000 M 999 240 HORZ(LL): -0.000 B - - HORZ(TL): 0.000 B - - Creep Factor: 2.0 Max TC CSI: 0.101 Max BC CSI: 0.009 Max Web CSI: 0.032 Weight: 86.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL05GE Truss Type SY42 Qty 1 Ply 1 Seal #: 2543 05/29/2021 1'3-5/8" 2'7-5/8"14'7-5/8"16'0-3/4" 3-5/8" 3-5/8"1'4"3-5/8" 1'4" (TYP) 16'0-3/4" SEAT PLATE REQ. A B C D E F G H I J K L M N O PQRSTUVWXYZAA AB AC 1.5X3(R) 1.5X3(R) 3X3 3X3 2X4(R) 1.5X3(R) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 37 0.25 3.32 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL F 197 /- /- /- /- /- D 179 /- /- /- /- /- F Brg Width = - Min Req = - D Brg Width = 3.5 Min Req = 1.5 Bearing D is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 6 0 Chords Tens. Comp. B - C 0 -17 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. F - E 255 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - F 0 -93 F - B 0 -278 B - E 0 -248 Webs Tens. Comp. C - E 0 -79 E - C 0 -13 E - D 0 -179 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.009 B 999 360 VERT(CL): 0.012 B 999 240 HORZ(LL): 0.001 E - - HORZ(TL): 0.001 E - - Creep Factor: 2.0 Max TC CSI: 0.132 Max BC CSI: 0.146 Max Web CSI: 0.065 Weight: 25.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL06 Truss Type SY42 Qty 1 Ply 1 Seal #: 2544 05/29/2021 3'5-3/8"8"1'5-11/16" (TYP) 3'5-3/8" A B C D EF 2X4 3X6 3X4 2X4 3X6 1.5X3 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 37 0.25 3.32 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL F 197 /- /- /- /- /- D 179 /- /- /- /- /- F Brg Width = - Min Req = - D Brg Width = 3.5 Min Req = 1.5 Bearing D is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 6 0 Chords Tens. Comp. B - C 0 -17 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. F - E 255 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - F 0 -93 F - B 0 -278 B - E 0 -248 Webs Tens. Comp. C - E 0 -79 E - C 0 -13 E - D 0 -179 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.009 B 999 360 VERT(CL): 0.012 B 999 240 HORZ(LL): 0.001 E - - HORZ(TL): 0.001 E - - Creep Factor: 2.0 Max TC CSI: 0.132 Max BC CSI: 0.146 Max Web CSI: 0.065 Weight: 25.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL06 Truss Type SY42 Qty 1 Ply 1 Seal #: 2544 05/29/2021 3'5-3/8"8"1'5-11/16" (TYP) 3'5-3/8" A B C D EF 2X4 3X6 3X4 2X4 3X6 1.5X3 Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 :SP 2400f-2.0E + SP M-31:; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 50 plf at 0.00 to 50 plf at 6.59 BC: From 5 plf at 0.00 to 5 plf at 6.59 TC: 748 lb Conc. Load at 0.97, 2.97, 4.97 TC: 705 lb Conc. Load at 5.45 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 73 0.25 6.34 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL H 1528 /- /- /- /- /- E 1784 /- /- /- /- /- H Brg Width = 12.0 Min Req = 1.5 E Brg Width = - Min Req = - Bearing H is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -163 B - C 0 -2119 Chords Tens. Comp. C - D 0 -2064 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. H - G 2117 0 G - F 2119 0 Chords Tens. Comp. F - E 203 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - H 754 -1375 H - B 0 -2143 B - G 35 0 C - F 0 -1003 Webs Tens. Comp. F - D 2095 0 E - D 935 0 D - E 0 -2670 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.099 C 737 360 VERT(CL): 0.136 C 536 240 HORZ(LL): 0.010 E - - HORZ(TL): 0.014 E - - Creep Factor: 2.0 Max TC CSI: 0.904 Max BC CSI: 0.935 Max Web CSI: 0.998 Weight: 46.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL07G Truss Type SY42 Qty 1 Ply 1 Seal #: 2552 05/29/2021 2'9"4'0-1/2"6'7-1/8"1'3-3/4"1'2" 6'7-1/8" A B C D EFGH 3X6 4X8 5X6 1.5X3 3X6 4X6 6X8 3X4(R) 11-5/8" 748# 2' 748# 2' 748# 5-3/4"705#1'1-3/4" **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 :SP 2400f-2.0E + SP M-31:; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 50 plf at 0.00 to 50 plf at 6.59 BC: From 5 plf at 0.00 to 5 plf at 6.59 TC: 748 lb Conc. Load at 0.97, 2.97, 4.97 TC: 705 lb Conc. Load at 5.45 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 73 0.25 6.34 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL H 1528 /- /- /- /- /- E 1784 /- /- /- /- /- H Brg Width = 12.0 Min Req = 1.5 E Brg Width = - Min Req = - Bearing H is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -163 B - C 0 -2119 Chords Tens. Comp. C - D 0 -2064 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. H - G 2117 0 G - F 2119 0 Chords Tens. Comp. F - E 203 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - H 754 -1375 H - B 0 -2143 B - G 35 0 C - F 0 -1003 Webs Tens. Comp. F - D 2095 0 E - D 935 0 D - E 0 -2670 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.099 C 737 360 VERT(CL): 0.136 C 536 240 HORZ(LL): 0.010 E - - HORZ(TL): 0.014 E - - Creep Factor: 2.0 Max TC CSI: 0.904 Max BC CSI: 0.935 Max Web CSI: 0.998 Weight: 46.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL07G Truss Type SY42 Qty 1 Ply 1 Seal #: 2552 05/29/2021 2'9"4'0-1/2"6'7-1/8"1'3-3/4"1'2" 6'7-1/8" A B C D EFGH 3X6 4X8 5X6 1.5X3 3X6 4X6 6X8 3X4(R) 11-5/8" 748# 2' 748# 2' 748# 5-3/4"705#1'1-3/4" Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 402 plf at 0.00 to 402 plf at 3.42 BC: From 10 plf at 0.00 to 10 plf at 3.42 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 35 0.25 3.17 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL E 705 /- /- /- /- /- D 704 /- /- /- /- /- E Brg Width = - Min Req = - D Brg Width = 3.5 Min Req = 1.5 Bearing D is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 11 0 Chords Tens. Comp. B - C 11 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. E - D 443 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - E 0 -334 E - B 0 -578 B - D 0 -576 Webs Tens. Comp. D - C 0 -54 C - D 0 -287 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.009 B 999 360 VERT(CL): 0.013 B 999 240 HORZ(LL): 0.001 D - - HORZ(TL): 0.001 D - - Creep Factor: 2.0 Max TC CSI: 0.696 Max BC CSI: 0.103 Max Web CSI: 0.138 Weight: 28.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL08 Truss Type SY42 Qty 1 Ply 1 Seal #: 2545 05/29/2021 3'5"1'4"1'5-1/2" (TYP) 3'5" A B C DE 2X4 4X6 3X3 2X4 4X6 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Special Loads ------(Lumber Dur.Fac.=1.00 / Plate Dur.Fac.=1.00) TC: From 402 plf at 0.00 to 402 plf at 3.42 BC: From 10 plf at 0.00 to 10 plf at 3.42 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 35 0.25 3.17 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL E 705 /- /- /- /- /- D 704 /- /- /- /- /- E Brg Width = - Min Req = - D Brg Width = 3.5 Min Req = 1.5 Bearing D is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 11 0 Chords Tens. Comp. B - C 11 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. E - D 443 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. A - E 0 -334 E - B 0 -578 B - D 0 -576 Webs Tens. Comp. D - C 0 -54 C - D 0 -287 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: No FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.009 B 999 360 VERT(CL): 0.013 B 999 240 HORZ(LL): 0.001 D - - HORZ(TL): 0.001 D - - Creep Factor: 2.0 Max TC CSI: 0.696 Max BC CSI: 0.103 Max Web CSI: 0.138 Weight: 28.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL08 Truss Type SY42 Qty 1 Ply 1 Seal #: 2545 05/29/2021 3'5"1'4"1'5-1/2" (TYP) 3'5" A B C DE 2X4 4X6 3X3 2X4 4X6 Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 78 0.25 6.73 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL I 370 /- /- /- /- /- F 370 /- /- /- /- /- I Brg Width = 6.9 Min Req = 1.5 F Brg Width = 8.9 Min Req = 1.5 Bearings I & F are a rigid surface. Bearing I requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -488 Chords Tens. Comp. C - D 1 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. I - H 487 0 H - G 488 0 Chords Tens. Comp. G - F 487 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. J - K 0 -5 A - I 0 -122 I - B 0 -541 B - H 70 -30 Webs Tens. Comp. G - C 70 -30 C - F 0 -541 D - F 0 -122 E - L 0 -5 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.027 H 999 360 VERT(CL): 0.043 H 999 240 HORZ(LL): 0.007 B - - HORZ(TL): 0.012 B - - Creep Factor: 2.0 Max TC CSI: 0.429 Max BC CSI: 0.281 Max Web CSI: 0.150 Weight: 42.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL09 Truss Type SY42 Qty 1 Ply 1 Seal #: 2546 05/29/2021 2'9"4'1-1/4"6'11-3/4" 3-5/8" 3-5/8"1'4"3-5/8" 3-5/8" 1'2-3/4" 2'6" (TYP) 6'11-3/4" SEAT PLATE REQ. A B C D E FGH I J K L 1.5X3(R) 1.5X3(R) 1.5X3 3X3 3X3 1.5X3 1.5X3 3X3 1.5X3 3X3 1.5X3(R) 1.5X3(R) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 78 0.25 6.73 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL I 370 /- /- /- /- /- F 370 /- /- /- /- /- I Brg Width = 6.9 Min Req = 1.5 F Brg Width = 8.9 Min Req = 1.5 Bearings I & F are a rigid surface. Bearing I requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -488 Chords Tens. Comp. C - D 1 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. I - H 487 0 H - G 488 0 Chords Tens. Comp. G - F 487 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. J - K 0 -5 A - I 0 -122 I - B 0 -541 B - H 70 -30 Webs Tens. Comp. G - C 70 -30 C - F 0 -541 D - F 0 -122 E - L 0 -5 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.027 H 999 360 VERT(CL): 0.043 H 999 240 HORZ(LL): 0.007 B - - HORZ(TL): 0.012 B - - Creep Factor: 2.0 Max TC CSI: 0.429 Max BC CSI: 0.281 Max Web CSI: 0.150 Weight: 42.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL09 Truss Type SY42 Qty 1 Ply 1 Seal #: 2546 05/29/2021 2'9"4'1-1/4"6'11-3/4" 3-5/8" 3-5/8"1'4"3-5/8" 3-5/8" 1'2-3/4" 2'6" (TYP) 6'11-3/4" SEAT PLATE REQ. A B C D E FGH I J K L 1.5X3(R) 1.5X3(R) 1.5X3 3X3 3X3 1.5X3 1.5X3 3X3 1.5X3 3X3 1.5X3(R) 1.5X3(R) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Bracing Sheathing is required for any longitudinal(drag) forces. All connections to be designed by the building designer. Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 117 0.25 10.04 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL J* 109 /- /- /- /- /- J Brg Width = 123 Min Req = - Bearing R is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 3 0 C - D 3 0 D - E 3 0 Chords Tens. Comp. E - F 3 0 F - G 3 0 G - H 3 0 H - I 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. R - Q 3 0 Q - P 0 -3 P - O 0 -3 O - N 0 -3 Chords Tens. Comp. N - M 0 -3 M - L 0 -3 L - K 0 -3 K - J 0 -3 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. S - T 0 -2 A - R 0 -36 R - B 0 -7 Webs Tens. Comp. J - I 0 -15 I - J 0 -43 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. B - Q 0 -119 C - P 0 -140 D - O 0 -132 E - N 0 -134 Gables Tens. Comp. F - M 0 -133 G - L 0 -136 H - K 0 -123 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 I 999 360 VERT(CL): 0.000 I 999 240 HORZ(LL): 0.000 I - - HORZ(TL): 0.000 I - - Creep Factor: 2.0 Max TC CSI: 0.083 Max BC CSI: 0.008 Max Web CSI: 0.031 Weight: 65.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL10GE Truss Type SY42 Qty 1 Ply 1 Seal #: 2547 05/29/2021 1'1"9'1"10'3-1/2" 3-5/8" 3-5/8"1'4"1'4" (TYP) 10'3-1/2" A B C D E F G H I J KLMNOPQ R S T 1.5X3(R) 1.5X3(R) 3X3 3X3 2X4 2X4(R) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Bracing Sheathing is required for any longitudinal(drag) forces. All connections to be designed by the building designer. Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 117 0.25 10.04 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL J* 109 /- /- /- /- /- J Brg Width = 123 Min Req = - Bearing R is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 3 0 C - D 3 0 D - E 3 0 Chords Tens. Comp. E - F 3 0 F - G 3 0 G - H 3 0 H - I 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. R - Q 3 0 Q - P 0 -3 P - O 0 -3 O - N 0 -3 Chords Tens. Comp. N - M 0 -3 M - L 0 -3 L - K 0 -3 K - J 0 -3 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. S - T 0 -2 A - R 0 -36 R - B 0 -7 Webs Tens. Comp. J - I 0 -15 I - J 0 -43 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. B - Q 0 -119 C - P 0 -140 D - O 0 -132 E - N 0 -134 Gables Tens. Comp. F - M 0 -133 G - L 0 -136 H - K 0 -123 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 I 999 360 VERT(CL): 0.000 I 999 240 HORZ(LL): 0.000 I - - HORZ(TL): 0.000 I - - Creep Factor: 2.0 Max TC CSI: 0.083 Max BC CSI: 0.008 Max Web CSI: 0.031 Weight: 65.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL10GE Truss Type SY42 Qty 1 Ply 1 Seal #: 2547 05/29/2021 1'1"9'1"10'3-1/2" 3-5/8" 3-5/8"1'4"1'4" (TYP) 10'3-1/2" A B C D E F G H I J KLMNOPQ R S T 1.5X3(R) 1.5X3(R) 3X3 3X3 2X4 2X4(R) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 14.69 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL N 808 /- /- /- /- /- I 822 /- /- /- /- /- N Brg Width = 6.9 Min Req = 1.5 I Brg Width = 3.5 Min Req = 1.5 Bearings N & I are a rigid surface. Bearing N requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -2185 C - D 0 -2185 D - E 0 -2333 Chords Tens. Comp. E - F 0 -2188 F - G 0 -2188 G - H 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. N - M 1390 0 M - L 2332 0 L - K 2333 0 Chords Tens. Comp. K - J 2334 0 J - I 1388 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. O - P 0 -4 A - N 0 -108 N - B 0 -1545 B - M 879 0 C - M 77 -217 M - D 80 -491 D - L 126 -111 Webs Tens. Comp. K - E 87 -112 E - J 78 -440 F - J 30 -232 J - G 884 0 G - I 0 -1545 I - H 0 -15 H - I 0 -112 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.193 K 896 360 VERT(CL): 0.244 E 709 240 HORZ(LL): 0.029 I - - HORZ(TL): 0.039 I - - Creep Factor: 2.0 Max TC CSI: 0.652 Max BC CSI: 0.896 Max Web CSI: 0.428 Weight: 88.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL11 Truss Type SY42 Qty 5 Ply 1 Seal #: 2548 05/29/2021 6'2-7/8"8'2-1/4"14'11-1/4" 3-5/8" 3-5/8"1'4"1'9-7/8" 2'6" (TYP) 14'11-1/4" SEAT PLATE REQ. + A B C D E F G H IJKLMN O P 1.5X3(R) 1.5X3(R) 1.5X3 3X6 3X6 1.5X3 3X8 3X3 1.5X3 1.5X3 3X3 1.5X3 3X8 3X6 2X4 3X6 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 14.69 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL N 808 /- /- /- /- /- I 822 /- /- /- /- /- N Brg Width = 6.9 Min Req = 1.5 I Brg Width = 3.5 Min Req = 1.5 Bearings N & I are a rigid surface. Bearing N requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -2185 C - D 0 -2185 D - E 0 -2333 Chords Tens. Comp. E - F 0 -2188 F - G 0 -2188 G - H 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. N - M 1390 0 M - L 2332 0 L - K 2333 0 Chords Tens. Comp. K - J 2334 0 J - I 1388 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. O - P 0 -4 A - N 0 -108 N - B 0 -1545 B - M 879 0 C - M 77 -217 M - D 80 -491 D - L 126 -111 Webs Tens. Comp. K - E 87 -112 E - J 78 -440 F - J 30 -232 J - G 884 0 G - I 0 -1545 I - H 0 -15 H - I 0 -112 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.193 K 896 360 VERT(CL): 0.244 E 709 240 HORZ(LL): 0.029 I - - HORZ(TL): 0.039 I - - Creep Factor: 2.0 Max TC CSI: 0.652 Max BC CSI: 0.896 Max Web CSI: 0.428 Weight: 88.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL11 Truss Type SY42 Qty 5 Ply 1 Seal #: 2548 05/29/2021 6'2-7/8"8'2-1/4"14'11-1/4" 3-5/8" 3-5/8"1'4"1'9-7/8" 2'6" (TYP) 14'11-1/4" SEAT PLATE REQ. + A B C D E F G H IJKLMN O P 1.5X3(R) 1.5X3(R) 1.5X3 3X6 3X6 1.5X3 3X8 3X3 1.5X3 1.5X3 3X3 1.5X3 3X8 3X6 2X4 3X6 Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 14.69 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL N 808 /- /- /- /- /- I 822 /- /- /- /- /- N Brg Width = 6.9 Min Req = 1.5 I Brg Width = - Min Req = - Bearing N is a rigid surface. Bearing N requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -2185 C - D 0 -2185 D - E 0 -2333 Chords Tens. Comp. E - F 0 -2188 F - G 0 -2188 G - H 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. N - M 1390 0 M - L 2332 0 L - K 2333 0 Chords Tens. Comp. K - J 2334 0 J - I 1388 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. O - P 0 -4 A - N 0 -108 N - B 0 -1545 B - M 879 0 C - M 77 -217 M - D 80 -491 D - L 126 -111 Webs Tens. Comp. K - E 87 -112 E - J 78 -440 F - J 30 -232 J - G 884 0 G - I 0 -1545 I - H 0 -15 H - I 0 -112 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.193 K 896 360 VERT(CL): 0.244 E 709 240 HORZ(LL): 0.029 I - - HORZ(TL): 0.039 I - - Creep Factor: 2.0 Max TC CSI: 0.652 Max BC CSI: 0.896 Max Web CSI: 0.428 Weight: 88.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL11A Truss Type SY42 Qty 1 Ply 1 Seal #: 2549 05/29/2021 6'2-7/8"8'2-1/4"14'11-1/4" 3-5/8" 3-5/8"1'4"1'9-7/8" 2'6" (TYP) 14'11-1/4" SEAT PLATE REQ. + A B C D E F G H IJKLMN O P 1.5X3(R) 1.5X3(R) 1.5X3 3X6 3X6 1.5X3 3X8 3X3 1.5X3 1.5X3 3X3 1.5X3 3X8 3X6 2X4 3X6 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.25 14.69 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Hangers / Ties (J) Hanger Support Required, by others Additional Notes + 2x6 continuous strongback. See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL N 808 /- /- /- /- /- I 822 /- /- /- /- /- N Brg Width = 6.9 Min Req = 1.5 I Brg Width = - Min Req = - Bearing N is a rigid surface. Bearing N requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 1 0 B - C 0 -2185 C - D 0 -2185 D - E 0 -2333 Chords Tens. Comp. E - F 0 -2188 F - G 0 -2188 G - H 3 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. N - M 1390 0 M - L 2332 0 L - K 2333 0 Chords Tens. Comp. K - J 2334 0 J - I 1388 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. O - P 0 -4 A - N 0 -108 N - B 0 -1545 B - M 879 0 C - M 77 -217 M - D 80 -491 D - L 126 -111 Webs Tens. Comp. K - E 87 -112 E - J 78 -440 F - J 30 -232 J - G 884 0 G - I 0 -1545 I - H 0 -15 H - I 0 -112 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.193 K 896 360 VERT(CL): 0.244 E 709 240 HORZ(LL): 0.029 I - - HORZ(TL): 0.039 I - - Creep Factor: 2.0 Max TC CSI: 0.652 Max BC CSI: 0.896 Max Web CSI: 0.428 Weight: 88.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL11A Truss Type SY42 Qty 1 Ply 1 Seal #: 2549 05/29/2021 6'2-7/8"8'2-1/4"14'11-1/4" 3-5/8" 3-5/8"1'4"1'9-7/8" 2'6" (TYP) 14'11-1/4" SEAT PLATE REQ. + A B C D E F G H IJKLMN O P 1.5X3(R) 1.5X3(R) 1.5X3 3X6 3X6 1.5X3 3X8 3X3 1.5X3 1.5X3 3X3 1.5X3 3X8 3X6 2X4 3X6 Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.19 14.75 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL AA 38 /- /- /- /- /- O* 111 /- /- /- /- /- AA Brg Width = 6.9 Min Req = 1.5 O Brg Width = 172 Min Req = - Bearings AA & Z are a rigid surface. Bearings AA & Z require a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 2 0 B - C 7 0 C - D 2 0 D - E 2 0 E - F 2 0 F - G 2 0 Chords Tens. Comp. G - H 2 0 H - I 2 0 I - J 2 0 J - K 2 0 K - L 2 0 L - M 2 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AA- Z 0 -2 Z - Y 6 0 Y - X 0 -2 X - W 0 -2 W - V 0 -2 V - U 0 -2 Chords Tens. Comp. U - T 0 -2 T - S 0 -2 S - R 0 -2 R - Q 0 -2 Q - P 0 -2 P - O 0 -2 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AB-AA 0 -36 A -AB 0 -16 Z - C 0 -18 Webs Tens. Comp. M - N 0 -13 O - N 0 -11 N - O 0 -23 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. B - Z 0 -105 C - Y 0 -127 D - X 0 -137 E - W 0 -132 F - V 0 -140 G - U 0 -133 Gables Tens. Comp. H - T 0 -140 I - S 0 -134 J - R 0 -133 K - Q 0 -138 L - P 0 -111 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 K 999 360 VERT(CL): 0.000 F 999 240 HORZ(LL): -0.000 B - - HORZ(TL): 0.000 B - - Creep Factor: 2.0 Max TC CSI: 0.082 Max BC CSI: 0.009 Max Web CSI: 0.032 Weight: 86.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL11GE Truss Type SY42 Qty 1 Ply 1 Seal #: 2550 05/29/2021 8-7/8" 2'0-7/8"14'0-7/8"14'11-1/4" 3-5/8"1'4"3-5/8" 1'4" (TYP) 14'11-1/4" SEAT PLATE REQ.SEAT PLATE REQ. A B C D E F G H I J K L M N O PQRSTUVWXYZ AA AB1.5X3(R) 2X4(R) 3X3 3X3 2X4(R) 1.5X3(R) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 4x2 SP #2; Bot chord: 4x2 SP #2; Webs: 4x2 SP #3; Plating Notes All plates are 1.5X3 except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 120 0.19 14.75 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Additional Notes See detail STRBRIBR1014 for bracing and bridging recommendations. Truss must be installed as shown with top chord up. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL AA 38 /- /- /- /- /- O* 111 /- /- /- /- /- AA Brg Width = 6.9 Min Req = 1.5 O Brg Width = 172 Min Req = - Bearings AA & Z are a rigid surface. Bearings AA & Z require a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 2 0 B - C 7 0 C - D 2 0 D - E 2 0 E - F 2 0 F - G 2 0 Chords Tens. Comp. G - H 2 0 H - I 2 0 I - J 2 0 J - K 2 0 K - L 2 0 L - M 2 0 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. AA- Z 0 -2 Z - Y 6 0 Y - X 0 -2 X - W 0 -2 W - V 0 -2 V - U 0 -2 Chords Tens. Comp. U - T 0 -2 T - S 0 -2 S - R 0 -2 R - Q 0 -2 Q - P 0 -2 P - O 0 -2 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. AB-AA 0 -36 A -AB 0 -16 Z - C 0 -18 Webs Tens. Comp. M - N 0 -13 O - N 0 -11 N - O 0 -23 Maximum Gable Forces Per Ply (lbs) Gables Tens.Comp. B - Z 0 -105 C - Y 0 -127 D - X 0 -137 E - W 0 -132 F - V 0 -140 G - U 0 -133 Gables Tens. Comp. H - T 0 -140 I - S 0 -134 J - R 0 -133 K - Q 0 -138 L - P 0 -111 Loading Criteria (psf) TCLL: 40.00 TCDL: 10.00 BCLL: 0.00 BCDL: 5.00 Des Ld: 55.00 NCBCLL: 0.00 Soffit: 0.00 Load Duration: 1.00 Spacing: 24.0 " Wind Criteria Wind Std: NA Speed: NA mph Enclosure: NA Category: NA EXP: NA Kzt: NA Mean Height: NA ft TCDL: NA psf BCDL: NA psf MWFRS Parallel Dist: NA C&C Dist a: NA ft Loc. from endwall: NA I: NA GCpi: NA Wind Duration: NA Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.000 K 999 360 VERT(CL): 0.000 F 999 240 HORZ(LL): -0.000 B - - HORZ(TL): 0.000 B - - Creep Factor: 2.0 Max TC CSI: 0.082 Max BC CSI: 0.009 Max Web CSI: 0.032 Weight: 86.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss FL11GE Truss Type SY42 Qty 1 Ply 1 Seal #: 2550 05/29/2021 8-7/8" 2'0-7/8"14'0-7/8"14'11-1/4" 3-5/8"1'4"3-5/8" 1'4" (TYP) 14'11-1/4" SEAT PLATE REQ.SEAT PLATE REQ. A B C D E F G H I J K L M N O PQRSTUVWXYZ AA AB1.5X3(R) 2X4(R) 3X3 3X3 2X4(R) 1.5X3(R) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From -0 plf at -1.98 to 61 plf at -0.10 TC: From 2 plf at -0.10 to 2 plf at 5.53 BC: From 2 plf at 0.00 to 2 plf at 5.36 TC: -25 lb Conc. Load at 1.46 TC: 129 lb Conc. Load at 4.29 BC: 10 lb Conc. Load at 1.46 BC: 86 lb Conc. Load at 4.29 Plating Notes All plates are 2X4(A1) except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 63 0.15 5.36 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B* 170 /- /- /- /149 /- E 150 /- /- /- /118 /- Wind reactions based on MWFRS B Brg Width = 17.0 Min Req = - E Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 19 -13 B - C 47 -25 Chords Tens. Comp. C - D 0 -2 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - F 17 -17 Chords Tens. Comp. F - E 0 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 86 -93 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.001 F - - HORZ(TL): 0.001 F - - Creep Factor: 2.0 Max TC CSI: 0.219 Max BC CSI: 0.184 Max Web CSI: 0.059 Weight: 22.4 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss HJ3P Truss Type HIP_ Qty 1 Ply 1 Seal #: 2511 05/29/2021 SEAT PLATE REQ. 5'2-3/4"1-1/2"1'11-13/16" 2-1/8" 5'4-1/4" 4-3/16"2'2-7/8"2'3-5/8"2'11-3/16"HB 3-5/8" A B C D EF 4.24 12 1.5X3 1.5X4 1'5-1/2" 10# -25# 2'9-15/16" 86# 129#1'0-13/16" **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From -0 plf at -1.98 to 61 plf at -0.10 TC: From 2 plf at -0.10 to 2 plf at 5.53 BC: From 2 plf at 0.00 to 2 plf at 5.36 TC: -25 lb Conc. Load at 1.46 TC: 129 lb Conc. Load at 4.29 BC: 10 lb Conc. Load at 1.46 BC: 86 lb Conc. Load at 4.29 Plating Notes All plates are 2X4(A1) except as noted. Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 63 0.15 5.36 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B* 170 /- /- /- /149 /- E 150 /- /- /- /118 /- Wind reactions based on MWFRS B Brg Width = 17.0 Min Req = - E Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 19 -13 B - C 47 -25 Chords Tens. Comp. C - D 0 -2 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - F 17 -17 Chords Tens. Comp. F - E 0 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 86 -93 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.001 F - - HORZ(TL): 0.001 F - - Creep Factor: 2.0 Max TC CSI: 0.219 Max BC CSI: 0.184 Max Web CSI: 0.059 Weight: 22.4 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss HJ3P Truss Type HIP_ Qty 1 Ply 1 Seal #: 2511 05/29/2021 SEAT PLATE REQ. 5'2-3/4"1-1/2"1'11-13/16" 2-1/8" 5'4-1/4" 4-3/16"2'2-7/8"2'3-5/8"2'11-3/16"HB 3-5/8" A B C D EF 4.24 12 1.5X3 1.5X4 1'5-1/2" 10# -25# 2'9-15/16" 86# 129#1'0-13/16" Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP M-30; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From -0 plf at -1.98 to 61 plf at -0.10 TC: From 2 plf at -0.10 to 2 plf at 9.84 BC: From 2 plf at 0.00 to 2 plf at 9.84 TC: -25 lb Conc. Load at 1.46 TC: 129 lb Conc. Load at 4.29 TC: 255 lb Conc. Load at 7.12 BC: 10 lb Conc. Load at 1.46 BC: 86 lb Conc. Load at 4.29 BC: 155 lb Conc. Load at 7.12 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 116 0.15 9.84 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 321 /- /- /- /266 /- E 331 /- /- /- /141 /- D 68 /- /- /- /56 /- Wind reactions based on MWFRS B Brg Width = 4.2 Min Req = 1.5 E Brg Width = 1.5 Min Req = - D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 19 -13 B - C 410 -494 Chords Tens. Comp. C - D 51 -66 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - F 487 -361 Chords Tens. Comp. F - E 0 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 392 -529 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.021 F 999 360 VERT(CL): 0.053 F 999 240 HORZ(LL): 0.009 F - - HORZ(TL): 0.022 F - - Creep Factor: 2.0 Max TC CSI: 0.520 Max BC CSI: 0.619 Max Web CSI: 0.264 Weight: 40.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss HJ7 Truss Type HIP_ Qty 5 Ply 1 Seal #: 2513 05/29/2021 9'10-1/16"1'11-13/16" 4-3/16"3'9-7/8"4'5-7/16"A B C D EF 4.24 12 2X4(A1) 1.5X3 4X4 1'5-1/2" 10# -25# 2'9-15/16" 86# 129# 2'9-15/16" 155# 255# 2'8-11/16" **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP M-30; Webs: 2x4 SP #3; Special Loads ------(Lumber Dur.Fac.=1.25 / Plate Dur.Fac.=1.25) TC: From -0 plf at -1.98 to 61 plf at -0.10 TC: From 2 plf at -0.10 to 2 plf at 9.84 BC: From 2 plf at 0.00 to 2 plf at 9.84 TC: -25 lb Conc. Load at 1.46 TC: 129 lb Conc. Load at 4.29 TC: 255 lb Conc. Load at 7.12 BC: 10 lb Conc. Load at 1.46 BC: 86 lb Conc. Load at 4.29 BC: 155 lb Conc. Load at 7.12 Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 116 0.15 9.84 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads and reactions based on MWFRS. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 321 /- /- /- /266 /- E 331 /- /- /- /141 /- D 68 /- /- /- /56 /- Wind reactions based on MWFRS B Brg Width = 4.2 Min Req = 1.5 E Brg Width = 1.5 Min Req = - D Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 19 -13 B - C 410 -494 Chords Tens. Comp. C - D 51 -66 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - F 487 -361 Chords Tens. Comp. F - E 0 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - F 392 -529 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Varies by Ld Case FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.021 F 999 360 VERT(CL): 0.053 F 999 240 HORZ(LL): 0.009 F - - HORZ(TL): 0.022 F - - Creep Factor: 2.0 Max TC CSI: 0.520 Max BC CSI: 0.619 Max Web CSI: 0.264 Weight: 40.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss HJ7 Truss Type HIP_ Qty 5 Ply 1 Seal #: 2513 05/29/2021 9'10-1/16"1'11-13/16" 4-3/16"3'9-7/8"4'5-7/16"A B C D EF 4.24 12 2X4(A1) 1.5X3 4X4 1'5-1/2" 10# -25# 2'9-15/16" 86# 129# 2'9-15/16" 155# 255# 2'8-11/16" Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 10 0.15 1.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 218 /- /- /196 /115 /57 D 5 /-14 /- /19 /17 /- C - /-40 /- /44 /50 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 Chords Tens. Comp. B - C 63 -33 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - D 0 0 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.000 D - - HORZ(TL): 0.000 D - - Creep Factor: 2.0 Max TC CSI: 0.318 Max BC CSI: 0.042 Max Web CSI: 0.000 Weight: 5.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss J1 Truss Type JACK Qty 12 Ply 1 Seal #: 2500 05/29/2021 1' 1'5-9/16" 4-3/16" 10-3/16"1'5-15/16"A B C D 6 12 2X4(A1) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 10 0.15 1.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 218 /- /- /196 /115 /57 D 5 /-14 /- /19 /17 /- C - /-40 /- /44 /50 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 Chords Tens. Comp. B - C 63 -33 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - D 0 0 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): -0.000 D - - HORZ(TL): 0.000 D - - Creep Factor: 2.0 Max TC CSI: 0.318 Max BC CSI: 0.042 Max Web CSI: 0.000 Weight: 5.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss J1 Truss Type JACK Qty 12 Ply 1 Seal #: 2500 05/29/2021 1' 1'5-9/16" 4-3/16" 10-3/16"1'5-15/16"A B C D 6 12 2X4(A1) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 34 0.15 3.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 233 /- /- /179 /93 /109 D 43 /- /- /20 /- /- C 64 /- /- /34 /56 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 Chords Tens. Comp. B - C 29 -75 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - D 0 0 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.001 D - - HORZ(TL): 0.001 D - - Creep Factor: 2.0 Max TC CSI: 0.358 Max BC CSI: 0.064 Max Web CSI: 0.000 Weight: 11.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss J3 Truss Type JACK Qty 10 Ply 1 Seal #: 2502 05/29/2021 3'1'5-9/16" 4-3/16"1'10-3/16"2'5-15/16"A B C D 6 12 2X4(A1) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 34 0.15 3.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 233 /- /- /179 /93 /109 D 43 /- /- /20 /- /- C 64 /- /- /34 /56 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 Chords Tens. Comp. B - C 29 -75 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - D 0 0 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.001 D - - HORZ(TL): 0.001 D - - Creep Factor: 2.0 Max TC CSI: 0.358 Max BC CSI: 0.064 Max Web CSI: 0.000 Weight: 11.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss J3 Truss Type JACK Qty 10 Ply 1 Seal #: 2502 05/29/2021 3'1'5-9/16" 4-3/16"1'10-3/16"2'5-15/16"A B C D 6 12 2X4(A1) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 34 0.15 3.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 233 /- /- /215 /98 /109 D 43 /- /- /58 /30 /- C 64 /- /- /37 /55 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 Chords Tens. Comp. B - C 29 -82 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - D 0 0 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.000 D - - HORZ(TL): 0.001 D - - Creep Factor: 2.0 Max TC CSI: 0.287 Max BC CSI: 0.057 Max Web CSI: 0.000 Weight: 11.2 lbs VIEW Ver: 20.02.01A.1209.11 Job: CRMSWSB2 Truss J3P Truss Type JACK Qty 2 Ply 1 Seal #: 2535 05/29/2021 3'1'5-9/16" 4-3/16"1'10-3/16"2'5-15/16"A B C D 6 12 2X4(A1) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 34 0.15 3.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 233 /- /- /215 /98 /109 D 43 /- /- /58 /30 /- C 64 /- /- /37 /55 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 Chords Tens. Comp. B - C 29 -82 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - D 0 0 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.000 D - - HORZ(TL): 0.001 D - - Creep Factor: 2.0 Max TC CSI: 0.287 Max BC CSI: 0.057 Max Web CSI: 0.000 Weight: 11.2 lbs VIEW Ver: 20.02.01A.1209.11 Job: CRMSWSB2 Truss J3P Truss Type JACK Qty 2 Ply 1 Seal #: 2535 05/29/2021 3'1'5-9/16" 4-3/16"1'10-3/16"2'5-15/16"A B C D 6 12 2X4(A1) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 45 0.15 3.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 261 /- /- /241 /104 /135 E 130 /- /- /122 /66 /- Wind reactions based on MWFRS B Brg Width = 12.0 Min Req = 1.5 E Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 36 -118 Chords Tens. Comp. C - D 0 -3 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - E 6 -11 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - E 220 -100 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.001 E - - HORZ(TL): 0.003 E - - Creep Factor: 2.0 Max TC CSI: 0.318 Max BC CSI: 0.116 Max Web CSI: 0.117 Weight: 18.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss J4P Truss Type EJAC Qty 1 Ply 1 Seal #: 2504 05/29/2021 SEAT PLATE REQ. 3'10-1/2"1'5-9/16"1-1/2" 4-3/16"2'3-7/16"2'4-3/16"2'11-15/16"HB 1-1/2" A B C D E 6 12 2X4(A1) 1.5X3 3X6 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 45 0.15 3.88 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Left bottom chord exposed to wind. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 261 /- /- /241 /104 /135 E 130 /- /- /122 /66 /- Wind reactions based on MWFRS B Brg Width = 12.0 Min Req = 1.5 E Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Bearing B requires a seat plate. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 B - C 36 -118 Chords Tens. Comp. C - D 0 -3 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - E 6 -11 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. C - E 220 -100 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: Any GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.001 E - - HORZ(TL): 0.003 E - - Creep Factor: 2.0 Max TC CSI: 0.318 Max BC CSI: 0.116 Max Web CSI: 0.117 Weight: 18.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss J4P Truss Type EJAC Qty 1 Ply 1 Seal #: 2504 05/29/2021 SEAT PLATE REQ. 3'10-1/2"1'5-9/16"1-1/2" 4-3/16"2'3-7/16"2'4-3/16"2'11-15/16"HB 1-1/2" A B C D E 6 12 2X4(A1) 1.5X3 3X6 Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 58 0.15 5.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 299 /- /- /213 /106 /161 D 77 /- /- /36 /- /- C 127 /- /- /75 /107 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 Chords Tens. Comp. B - C 57 -118 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - D 0 0 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.004 D - - HORZ(TL): 0.008 D - - Creep Factor: 2.0 Max TC CSI: 0.387 Max BC CSI: 0.218 Max Web CSI: 0.000 Weight: 18.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss J5 Truss Type JACK Qty 10 Ply 1 Seal #: 2505 05/29/2021 5'1'5-9/16" 4-3/16"2'10-3/16"3'5-15/16"A B C D 6 12 2X4(A1) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 58 0.15 5.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 299 /- /- /213 /106 /161 D 77 /- /- /36 /- /- C 127 /- /- /75 /107 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 Chords Tens. Comp. B - C 57 -118 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - D 0 0 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.004 D - - HORZ(TL): 0.008 D - - Creep Factor: 2.0 Max TC CSI: 0.387 Max BC CSI: 0.218 Max Web CSI: 0.000 Weight: 18.2 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss J5 Truss Type JACK Qty 10 Ply 1 Seal #: 2505 05/29/2021 5'1'5-9/16" 4-3/16"2'10-3/16"3'5-15/16"A B C D 6 12 2X4(A1) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.15 7.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 371 /- /- /254 /122 /213 D 111 /- /- /54 /- /- C 186 /- /- /112 /155 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 Chords Tens. Comp. B - C 83 -152 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - D 0 0 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.014 D - - HORZ(TL): 0.027 D - - Creep Factor: 2.0 Max TC CSI: 0.704 Max BC CSI: 0.449 Max Web CSI: 0.000 Weight: 23.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss J7 Truss Type EJAC Qty 22 Ply 1 Seal #: 2507 05/29/2021 7'1'5-9/16" 4-3/16"3'10-3/16"4'5-15/16"A B C D 6 12 2X4(A1) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 75 0.15 7.00 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Maximum Reactions (lbs) Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL B 371 /- /- /254 /122 /213 D 111 /- /- /54 /- /- C 186 /- /- /112 /155 /- Wind reactions based on MWFRS B Brg Width = 3.5 Min Req = 1.5 D Brg Width = 1.5 Min Req = - C Brg Width = 1.5 Min Req = - Bearing B is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 39 0 Chords Tens. Comp. B - C 83 -152 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. B - D 0 0 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: 0 to h/2 C&C Dist a: 3.00 ft Loc. from endwall: not in 4.50 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): NA VERT(CL): NA HORZ(LL): 0.014 D - - HORZ(TL): 0.027 D - - Creep Factor: 2.0 Max TC CSI: 0.704 Max BC CSI: 0.449 Max Web CSI: 0.000 Weight: 23.8 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss J7 Truss Type EJAC Qty 22 Ply 1 Seal #: 2507 05/29/2021 7'1'5-9/16" 4-3/16"3'10-3/16"4'5-15/16"A B C D 6 12 2X4(A1) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 24 0.00 1.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes See A1 Std Detail for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL D* 76 /- /- /38 /8 /12 Wind reactions based on MWFRS D Brg Width = 23.5 Min Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -23 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A - C 76 -8 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.006 B 999 360 VERT(CL): 0.012 B 999 240 HORZ(LL): 0.003 B - - HORZ(TL): 0.005 B - - Creep Factor: 2.0 Max TC CSI: 0.071 Max BC CSI: 0.124 Max Web CSI: 0.000 Weight: 5.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss V01 Truss Type VAL Qty 1 Ply 1 Seal #: 2508 05/29/2021 1'11-1/2" 6-15/16"1'4-9/16" 0-1/4"1'A B CD 6 12 2X4(D8R) **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 24 0.00 1.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes See A1 Std Detail for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL D* 76 /- /- /38 /8 /12 Wind reactions based on MWFRS D Brg Width = 23.5 Min Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 0 -23 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A - C 76 -8 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.006 B 999 360 VERT(CL): 0.012 B 999 240 HORZ(LL): 0.003 B - - HORZ(TL): 0.005 B - - Creep Factor: 2.0 Max TC CSI: 0.071 Max BC CSI: 0.124 Max Web CSI: 0.000 Weight: 5.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss V01 Truss Type VAL Qty 1 Ply 1 Seal #: 2508 05/29/2021 1'11-1/2" 6-15/16"1'4-9/16" 0-1/4"1'A B CD 6 12 2X4(D8R) Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 48 0.00 3.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes See A1 Std Detail for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL F* 76 /- /- /43 /13 /15 Wind reactions based on MWFRS F Brg Width = 47.5 Min Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 35 -126 Chords Tens. Comp. B - C 0 -23 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A - E 4 -6 Chords Tens. Comp. E - D 0 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B - E 264 -137 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.004 E 999 360 VERT(CL): 0.008 E 999 240 HORZ(LL): 0.002 E - - HORZ(TL): 0.003 E - - Creep Factor: 2.0 Max TC CSI: 0.105 Max BC CSI: 0.100 Max Web CSI: 0.092 Weight: 12.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss V02 Truss Type VAL Qty 1 Ply 1 Seal #: 2509 05/29/2021 3'11-1/2" 6-15/16"3'4-9/16" 2'10"3-1/2" 10" 0-1/4"2'A B C D E F 6 12 2X4(D8R) 1.5X3 3X6 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 48 0.00 3.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Wind loading based on both gable and hip roof types. Additional Notes See A1 Std Detail for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL F* 76 /- /- /43 /13 /15 Wind reactions based on MWFRS F Brg Width = 47.5 Min Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 35 -126 Chords Tens. Comp. B - C 0 -23 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A - E 4 -6 Chords Tens. Comp. E - D 0 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B - E 264 -137 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.004 E 999 360 VERT(CL): 0.008 E 999 240 HORZ(LL): 0.002 E - - HORZ(TL): 0.003 E - - Creep Factor: 2.0 Max TC CSI: 0.105 Max BC CSI: 0.100 Max Web CSI: 0.092 Weight: 12.6 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss V02 Truss Type VAL Qty 1 Ply 1 Seal #: 2509 05/29/2021 3'11-1/2" 6-15/16"3'4-9/16" 2'10"3-1/2" 10" 0-1/4"2'A B C D E F 6 12 2X4(D8R) 1.5X3 3X6 Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 72 0.00 5.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Additional Notes See A1 Std Detail for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL F* 76 /- /- /45 /14 /16 Wind reactions based on MWFRS F Brg Width = 71.5 Min Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 53 -153 Chords Tens. Comp. B - C 0 -28 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A - E 7 -10 Chords Tens. Comp. E - D 0 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B - E 304 -194 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.017 E 999 360 VERT(CL): 0.032 E 999 240 HORZ(LL): -0.009 C - - HORZ(TL): 0.018 C - - Creep Factor: 2.0 Max TC CSI: 0.267 Max BC CSI: 0.241 Max Web CSI: 0.137 Weight: 21.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss V03 Truss Type VAL Qty 1 Ply 1 Seal #: 2510 05/29/2021 5'11-1/2" 6-15/16"5'4-9/16" 4'8"3-1/2" 1' 0-1/4"3'A B C D E F 6 12 2X4(D8R) 1.5X3 1.5X3 **WARNING**Please thoroughly review the ''A-1 ROOF TRUSSES (''SELLER''), GENERAL TERMS and CONDITIONS CUSTOMER (''BUYER'') ACKNOWLEDGMENT'' form. Verify design parameters and read notes on this Truss Design Drawing (TDD) and the Specialty Engineer reference sheet before use. Unless otherwise stated on the TDD, only Alpine connector plates shall be used for the TDD to be valid. As a Truss Design Engineering (i.e. Specialty Engineer), the seal on any TDD represents an acceptance of the professional engineering responsibility for the design of the single Truss depicted on the TDD only, under TPI-1. The design assumptions, loading conditions, suitability and use of this Truss for any Building is the responsibility of the Owner, the Owner’s authorized agent or the Building Designer, in the context of the IRC, the IBC, local building code and TPI-1. The approval of the TDD and any field use of the Truss, including handling, storage, installation and bracing shall be the responsibility of the Building Designer and Contractor. All notes set out in the TDD and the practices and guidelines of the Building Component Safety Information (BSCI) published by TPI and SBCA are referenced for general guidance. TPI-1 defines the responsibilities and duties of the Truss Designer, Specialty Engineer and Truss Manufacturer, unless otherwise defined by a Contract agreed upon in writing by all parties involved. The Specialty Engineer is NOT the Building Designer or Truss System Engineer of any building. All capitalized terms are as defined in TPI-1. Copyright © 2016 A-1 Roof Trusses – Reproduction of this document, in any form, is prohibited without the written permission of A-1 Roof Trusses. Lumber Top chord: 2x4 SP #2; Bot chord: 2x4 SP #2; Webs: 2x4 SP #3; Purlins In lieu of structural panels or rigid ceiling use purlins to laterally brace chords as follows: Chord Spacing(in oc) Start(ft) End(ft) BC 72 0.00 5.96 Apply purlins to any chords above or below fillers at 24" OC unless shown otherwise above. Wind Wind loads based on MWFRS with additional C&C member design. Right end vertical not exposed to wind pressure. Wind loading based on both gable and hip roof types. Additional Notes See A1 Std Detail for valley details. Maximum Reactions (lbs), or *=PLF Gravity Non-Gravity Loc R+ / R- / Rh / Rw / U / RL F* 76 /- /- /45 /14 /16 Wind reactions based on MWFRS F Brg Width = 71.5 Min Req = - Bearing A is a rigid surface. Maximum Top Chord Forces Per Ply (lbs) Chords Tens.Comp. A - B 53 -153 Chords Tens. Comp. B - C 0 -28 Maximum Bot Chord Forces Per Ply (lbs) Chords Tens.Comp. A - E 7 -10 Chords Tens. Comp. E - D 0 0 Maximum Web Forces Per Ply (lbs) Webs Tens.Comp. B - E 304 -194 Loading Criteria (psf) TCLL: 20.00 TCDL: 10.00 BCLL: 0.00 BCDL: 7.00 Des Ld: 37.00 NCBCLL: 10.00 Soffit: 0.00 Load Duration: 1.25 Spacing: 24.0 " Wind Criteria Wind Std: ASCE 7-16 Speed: 160 mph Enclosure: Closed Risk Category: II EXP: B Kzt: NA Mean Height: 25.00 ft TCDL: 5.0 psf BCDL: 4.2 psf MWFRS Parallel Dist: h/2 to h C&C Dist a: 3.00 ft Loc. from endwall: not in 9.00 ft GCpi: 0.18 Wind Duration: 1.60 Snow Criteria (Pg,Pf in PSF) Pg: NA Ct: NA CAT: NA Pf: NA Ce: NA Lu: NA Cs: NA Snow Duration: NA Building Code: FBC 7th Ed. 2020 Res. TPI Std: 2014 Rep Fac: Yes FT/RT:10(0)/10(10) Plate Type(s): WAVE Defl/CSI Criteria PP Deflection in loc L/defl L/# VERT(LL): 0.017 E 999 360 VERT(CL): 0.032 E 999 240 HORZ(LL): -0.009 C - - HORZ(TL): 0.018 C - - Creep Factor: 2.0 Max TC CSI: 0.267 Max BC CSI: 0.241 Max Web CSI: 0.137 Weight: 21.0 lbs VIEW Ver: 20.01.01A.0724.11 Job: CRMSWSB2 Truss V03 Truss Type VAL Qty 1 Ply 1 Seal #: 2510 05/29/2021 5'11-1/2" 6-15/16"5'4-9/16" 4'8"3-1/2" 1' 0-1/4"3'A B C D E F 6 12 2X4(D8R) 1.5X3 1.5X3 Ryan Bays, P.E.# 91231 4451 St. Lucie Blvd, Suite 201 Fort Pierce, FL 34946 Ryan Bays, P.E.# 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 NOTE: IN ADDITION TO STRAPPING TOE- NAIL BOTH CHORDS OF CORNER JACKS TO CARRYING MEMBER PER THE FOLLOWING SCHEDULE: 2X4: (2) 0.131" Ø TOE NAILS 2X6: (3) 0.131" Ø TOE NAILS HIGH VELOCITY HURRICANE ZONE CORNERSET SPECIFICATIONS: MAX LOAD: 55 PSF ROOF LOAD, 175 MPH, ASCE 7-10, EXP. B & C, UP TO 60' MEAN ROOF HEIGHT & EXPOSURE D UP TO 30' MEAN ROOF HEIGHT. JACK, OR CORNER JACK (TYP.) IMPORTANT NOTE: CONNECTION DESIGNED IN ACCORDANCE WITH FBC 2321.6- 2321.7 PROVIDING METAL STRAPPING (FLORIDA APPROVED PRODUCT) TO RESIST MIN. 700LB UPLIFT AT ALL CONNECTIONS IN HIGH VELOCITY HURRICANE ZONE. LSTA12 TWIST STRAP WITH 10D NAILS, MIN. (10). SEE MFR'S RECOMMENDED CONNECTION. HIP, OR KING JACK (TYP.)7'-0" MAX.ATTACH KING & END JACKS WITH (1) LSTA12 TWIST STRAP AT TOP CHORD WITH (10) 10d NAILS PER STRAP (MIN.) & (3) 0.131" Ø TOE NAILS. ATTACH KING & END JACK WITH (1) THJA26 HANGER AT BOTTOM CHORD. ATTACH CORNER JACKS & STD. JACKS WITH (1) LSTA12 TWIST STRAP AT TOP CHORD & BOTTOM CHORD WITH (10) 10d NAILS PER STRAP MINIMUM (TYP). A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL. 34946 (772) 409-1010 STDLHIP/ KING JACK (HVHZ) (SIMPSON)02.25/28/2020 OR EQUIVALENT AT BOTTOM CHORD Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 STDTL03ALTERNATE GABLE END BRACING DETAILFEBRUARY 17, 2017 Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 OPTION #2: APA RATED GUSSET. OPTION #3: 2X4 VERT. SCAB. PIGGY-BACK TRUSS. (REFER TO ACTUAL TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) ** IMPORTANT NOTE ** THIS DETAIL IS VALID ONLY FOR SINGLE PLY BASE TRUSSES SPACED AT 24" O.C. OR LESS. PIGGY-BACK DETAIL (TYPICAL) 180 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE C, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. OR... 160 MPH WIND, 30.00 FT MEAN ROOF HEIGHT, A.S.C.E. 7-10, PARTIALLY ENCLOSED BLDG. LOCATED ANYWHERE AT ROOF, EXPOSURE D, WIND D.L.= 5.0 P.S.F. (MIN.), KZT= 1.00. IMPORTANT NOTE: TOP CHORDS OF TRUSSES SUPPORTING PIGGY-BACK CAP TRUSSES MUST BE ADEQUATELY BRACED BY SHEATHING AND/ OR PURLINS. THE BUILDING ENGINEER OF RECORD SHALL PROVIDE DIAGONAL BRACING OR OTHER SUITABLE ANCHORAGE TO PERMANENTLY RESTRAIN PURLINS AND LATERAL BRACING FOR OUT OF PLANE LOADS OVER GABLE ENDS. MAXIMUM TRUSS SPACING IS NOT TO EXCEED 24" O.C. DETAIL IS NOT APPLICABLE IF CAP SUPPORTS ADDITIONAL LOADS SUCH AS CUPOLA, STEEPLE, CHIMNEY OR DRAG STRUT LOADS. **REFER TO ENGINEER'S SEALED TRUSS DESIGN DRAWINGS FOR PIGGY-BACK AND BASE TRUSS SPECIFICATIONS.** OPTION NO. 2 - APA RATED GUSSET: 8" x 8" x 0-7/16" (MIN.) APA RATED SHEATHING GUSSETS EACH FACE. ATTACH AT 8'-0" O.C. w/ 8 (EACH) 6d COMMON (0.113" x 2") NAILS PER GUSSET: 4 (EACH) AT CAP BOTTOM CHORD & 4 (EACH) AT BASE TRUSS TOP CHORD. GUSSETS MAY BE STAGGERED AT 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION NO. 3 - 2X4 VERTICAL WOOD SCAB: 2X4 SPF #2, FULL CHORD DEPTH SCABS AT EACH FACE. ATTACH AT 8'-0" O.C. w/6 (EACH) 10d BOX NAILS (0.128" x 3") PER SCAB: 3 (EACH) AT CAP BOTTOM CHORD AND 3 (EACH) AT BASE TRUSS TOP CHORD. SCABS MAY BE STAGGERED 4'-0" O.C. FRONT TO BACK FACES. MINIMUM TWO (2 EA.) CONNECTIONS AT EACH TRUSS. OPTION NO. 1 - TEE-LOK 3" x 8" TEE-LOK MULTI-USE CONNECTION PLATES SPACED AT 4'-0" O.C. MAX. PLATES SHALL BE PRESSED INTO PIGGY-BACK TRUSS AT 4'-0" O.C. STAGGERED FROM EACH FACE AND NAILED TO BASE TRUSS WITH 4 EACH 6d (1.5" X 0.099") NAILS IN EACH PLATE TO ACHEIVE MAXIMUM UPLIFT CAPACITY OF 377 LBS AT EACH 3" X 8" TEE-LOK MULTI-USE CONNECTION PLATE (MINIMUM OF 2 PLATES). OPTION #1: TEE-LOK MULTI-USE CONNECTION PLATE. ATTACH EACH PURLIN TO TOP CHORD OF BASE TRUSS. PURLIN & CONNECTIONS BY OTHERS. BASE TRUSS. (REFER TO TRUSS DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.) PURLINS SPACED ACCORDING TO MAX. SPACING OF TOP CHORD OF BASE TRUSS. SPACING IS NOT TO EXCEED 24" O.C. & PURLINS TO BE LOCATED AT JOINT OF EACH BASE TRUSS. 2'-0" MAX PIGGY-BACK TRUSS STDTL04.112/23/19 Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 STDTL05TRUSSED VALLEY SET DETAIL - SHEATHED P 12 VALLEY TRUSS (TYPICAL) BASE TRUSSES SEE DETAIL "A" BELOW (TYP.) VALLEY TRUSS (TYPICAL) GABLE END, COMMON TRUSS, OR GIRDER TRUSS SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS 6" O.C. DETAIL A TRUSS CRITERIA: WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24" O.C. (BASE AND VALLEY) MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. GABLE END, COMMON TRUSS, OR GIRDER TRUSS GENERAL SPECIFICATIONS: 1. NAIL SIZE = 3" X 0.131" = 10d 2. WOOD SCREW = 4.5" SDS25412 SIMPSON OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL "A". 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NDS - 01. 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. JULY 17, 2017 ATTACH 2X4 CONTINUOUS #2 SYP TO THE ROOF W/ TWO SIMPSON SDS25412 (1/4" X 4.5") OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 STDTL06TRUSSED VALLEY SET DETAIL P 12 VALLEY TRUSS (TYPICAL) BASE TRUSSES SEE DETAIL "A" BELOW (TYP.) VALLEY TRUSS (TYPICAL) GABLE END, COMMON TRUSS, OR GIRDER TRUSS SECURE VALLEY TRUSS W/ ONE ROW OF 10d NAILS 6" O.C. DETAIL A (NO SHEATHING) N.T.S. WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE C WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24" O.C. (BASE AND VALLEY) MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. GABLE END, COMMON TRUSS, OR GIRDER TRUSS GENERAL SPECIFICATIONS: 1. NAIL SIZE = 3" X 0.131" = 10d 2. WOOD SCREW = 3" SDS25300 SIMPSON OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24" O.C. MAXIMUM) AND SECURE PER DETAIL "A". 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIUAL DESIGN DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. 6. NAILING DONE PER NDS - 01. 7. VALLEY STUD SPACING NOT TO EXCEED 48" O.C. FEBRUARY 5, 2018 ATTACH 2X4 CONTINUOUS #2 SYP TO THE ROOF W/ TWO SIMPSON SDS25300 (1/4" X 3") OR EQUIVALENT WOOD SCREWS INTO EACH BASE TRUSS. Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 STDTL07TRUSSED VALLEY SET DETAIL (HIGH WIND VELOCITY) WIND DESIGN PER ASCE 7-98, ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT = 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24" O.C. (BASE AND VALLEY) SUPPORTING TRUSSES DIRECTLY UNDER VALLEY TRUSSES MUST BE DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' - 10" ON AFFECTED TOP CHORDS. NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6/12 (MAXIMUM 12/12 PITCH) CLIP MAY BE APPLIED TO THIS FACE UP TO A MAXIMUM 6/12 PITCH FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. NOTE: VALLEY STUD SPACING NOT TO EXCEED 48" O.C. SPACING. ATTACH VALLEY TRUSSES TO LOWER TRUSSES WITH USP RT7 OR EQUIVALENT. NON-BEVELED BOTTOM CHORD NON-BEVELED BOTTOM CHORD JULY 17, 2017 Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 MAXIMUM STUD LENGTH 2X4 SP #3 / STUD 12" O.C. 16" O.C. 24" O.C. 2X4 SP #3 / STUD 2X4 SP #3 / STUD 2X4 SP #2 12" O.C. 16" O.C. 24" O.C. 2X4 SP #2 2X4 SP #2 3-8-10 3-3-10 2-8-6 5-6-11 4-9-12 3-11-3 6-6-11 6-6-11 5-4-12 11-1-13 9-10-15 8-1-2 3-10-15 5-6-11 6-6-11 11-8-14 10-8-0 9-3-13 6-6-11 6-2-9 4-9-12 3-11-3 3-6-11 3-1-4 3X4 = 12 A A * * * MAX MEAN ROOF HEIGHT = 30 FEET EXPOSURE B OR C ASCE 7-10 190 MPH DURATION OF LOAD INCREASE : 1.60 STDTL08STANDARD GABLE END DETAIL B B + + + + ** STUD DESIGN IS BASED ON COMPONENTS AND CLADDING. CONNECTION OF BRACING IS BASED ON MWFRS. FEBRUARY 17, 2017 ** Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 STDTL09FEBRUARY 17, 2017 T-BRACE / I-BRACE DETAIL WITH 2X BRACE ONLY Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 STDTL10FEBRUARY 17, 2017 LATERAL BRACING RECOMMENDATIONS Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 45.00°45.00°45.00° STDTL11FEBRUARY 17, 2017 LATERAL TOE-NAIL DETAIL (2X6) 4 NAILS Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 L STDTL12FEBRUARY 17, 2017 UPLIFT TOE-NAIL DETAIL Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 FEBRUARY 5, 2016 ST-2x2 NAILINGTYP 2x2 NAILER ATTACHMENT A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 2x2 NAILER ATTACHMENT GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof Load, 170 mph, ASCE 7-10, 29'-0" Mean Height, Exp. B, C or D. 1.5 x 4 1.5 x 4 2 x 4 SP No . 2 (M in )2x4 SP No. 2 (Min) 2x2 SP No. 3 STDTL13 Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 April 11, 2016 ST-FLAT GIR BRACETYPICAL ALTERNATE BRACING DETAIL FO EXTERIOR FLAT GIRDER TRUSS A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 (4) 12d MAX 30" (2'-6") 2x6 #2 SP (Both Faces) 24" o.c. SIMPSON H5 (4) 12d TRUSS 24" o.c. UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT GIRDER VARIES 12 STDTL14 Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 STDTL15FEBRUARY 17, 2017 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND DAMAGED OR MISSING CHORD SPLICE PLATES Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946 STDTL16FEBRUARY 17, 2017 SCAB APPLIED OVERHANGS (L) 24" MAX (2.0 x L) 24" MIN Ryan Bays, P.E. # 912314451 St. Lucie Blvd, Suite 201Fort Pierce, FL 34946