Loading...
HomeMy WebLinkAboutProduct Review AffidavitPlanning& Development Services Department a ... Building Regulations Division Product Review Affidavit FL # or Miami -Dade FLORIDA PRODUCT APPROVAL REVISION REVISION EXPIRATION DATE product Model # Manufacturer Glass Description P Method of Building Design Product Design Pressure Pressure For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficient length to achive a 11/4" minimum embed. Into substrate. Locate anchors as FL17499.2 RS 10/08/2023 SH Window 185 SH MI Window and Non Impact p shown in elevations and installation details.For anchoring through frame into masonry Doors / concrete use 3/16" tapcons with sufficient length to achive a 1 1/4" minimum (+38) / (-48) (+50) / (-50) embed. Into substrate. Locate anchors as shown in elevations and installation details. For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficient length to achive a 13/8" minimum embed. Locate anchors as shown in installation details.For anchoring through frame into masonry / concrete use 1/4" FL15353.2 RS 12/31/2024 Vertical Mullion 5764 MI Window and Non Impact ELCO ultracon tapcons with sufficient length to achive a 1 1/4" minimum embed, w/ Doors 1' min. edge distance. Locate anchors as shown in installation details. (+38) / (-48j (+48.1 / (-48.1) For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficient length to achive a 1 1/4" minimum embed. Into substrate. Locate anchors as shown in elevations and installation details.For anchoring through frame into masonry FL15349.1 R14 4/3/2023 Fixed Window 185 PW MI Window and Non Impact / concrete use 3/16" tapcons with sufficient length to achive a 1 1/4" minimum' Doors embed. Into substrate wJ min 2 1/2" edge distance. Locate anchors as shown in (+38) / (-48) (+60) / (-60) installation details. For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficient length to achive a 13/8" minimum embed. Into substrate. Locate anchors as shown in elevations and installation details.For anchoring through frame into masonry FL15332.2 R6 12/31/2024 Sliding Glass Door Series 420 Aluminum SGD MI Window and Non Impact / concrete use 3/16" tapcons with sufficient length to achive a 1 1/4" minimum Doors embed. Into substrate w/ min 2 1/2" edge distance. Locate anchors as shown in +33 ( ) / (-41) (+48.2) / (-48.2) installation details. 1/4" concrete screw 6" edge distance @ head, 4" edge distance @ jamb, 4" each side FL20461.17 R6 12/31/2021 Opaque single of transom centerline to bucking. Fastener spacing @ 15" o/c max. @ head and jamb. door with transom Smooth Star Therma-Tru N/A Min. embedment of all anchors to be 1 1 4" / +36 47 ( ) / (- ) +47 -47 ( ) / ( ) FL16107.3 R13 R14 ( ) 12/31/2038, Double Garage 16.2x7 73 W6 Clopay N/A 3/8" x 2-3/4" Hilti sleeve anchors 6" from ends &' O/C PENDING APPROVAL Door (+29) / (35) (+36) / (-42) 3/8" Simpson Titen heavy duty screw anchor witfr 1'1/8" OD washer into grout filled CMU with min. emben of 23/4", min. edge distance of 4" and min. end distance of 4". FL8248.11 R20 1Z/31/2023 Double Garage 8024 Wayne Dalton N/A Max fastener spacing of 20". 3/8" dia. X 3" long lag screws with 1" OD washers with a Door ALT ( } 1 9/32"thread penetration into seasoned dry wood supporting structure.'` - (+29) / (-3S) '(+34.4) / (-38.3) 12J31/2023; Double Garage Series 170-175, 177, 180- 3/8" Simpson Titen heavy duty screw anchor with 2 3/4" embed min 6" between jamb FL14170.7 R14 R15 ( ) (PENDING APPROVAL) Door (ALT) 185, 187 Overhead N/A _ _ and bracket location. 2 3/4" min edge distance. (+29) / (-35) (+34.4) / (-38.3) Use galvanized (zinc coated) roofing nails, it or 12 gauge, with at least 3/8" dia. heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed 6-1/8" above the butt edge, approx. 1" and 13" from each end and 1/2" FL30310.1 R1 12/31/2024 Roof IKO SHINGLES IKO Cambridge N/A above each cutout. Drive nails straight so that nail head is flush with, but not cutting N/A N/A into shingle surface. Miami -Dade approved corrosion risistant tin caps and 12 ga. 1-1/4" annular ring shank nails spaced 6"O.C. at all laps and three staggard'rows fastened 12" O.C. in the field. FL15216.1 R8 12/31/2023 Underlayment RhinoRoof U20 Interwrap N/A FL5259.1 R32 12/23/2023 Underlayment (Alternate) Polystick IRXE Polyglass USA N/A Self adhesive FL17322.1 R7 12/31/2024 Underlayment (Alternate) WeatherMaster 100 Atlas Roofing Corp N/A Self adhesive - FL34546.1 R1 12/31/2024 Underlayment shield Granulated Owens corning N/A Self adhesive (Alternate) FL27076.16 R1 3 28 2023 / J Underlayment Weather Armor SB 1 APOC N/A Self adhesive (Alternate) FL3792.5 R14 8/16/2021 Off Ridge Vent 770D Lomanaco N/A Install per manufacturers recommended requirements. N/A N/A FL19567.2 R2 9/21/2026 Off Ridge Vent MMI MILLINUM METALS N/A Install per manufacturers recommended requirements. (ALTERNATE) N/A N/A FL33919.1 Rl 12/31/2024 Soffit Variform Soffits PlyGem N/A Install per manufacturers recommended requirements. (+31.6) / (-38.8) (+157) / (-46.1 12/31/2023, Install per manufacturers recommended requirements. FL15272.1 R4 (RS) (APPROVAL PENDING) Soffit (Alt) T2 Alside N/A (+31.6) / (-38.8) (+75) / (-75) 1/4" x 20 stainless steel or ELCO Panelmate with minimum embedment @ 13/4" in FL16293.1 R3 12/31/2021 Hurricane Panels 24 GAGE Hurricane Storm N/A concrete / masonry, 2 1/2" min. edge distance, 12" o/c max. spacing. Can be headed Less than 6' span panel MFG. screw or all thread but with wing nuts. N/A (+47) / (-53) 1/4" x 20 stainless steel or ELCO Panelmate with minimum embedment @ 1 3/4" in FL16293.1 R3 12/31/2021 Hurricane Panels 24 GAGE Hurricane Storm N/A concrete / masonry, 2 1 2' min. edge f spacing. / ' g distance, 12" o c max. s acin Can be headed 6' span or more panel MFG. screw or allthread but with wing nuts.. N/A (+45) / (-50) FL17147.1 RS 6/27/2021 Zip System Wall Sheathing Huber Install N/A per manufacturers recommended requirements. Sheathing N/A N/A Jaryfes Hardie Install per manufacturers recommended requirements. FL13192.2 R6 12/31/2023 Lap Siding Cemplank Building Products, N/A Inc FL1392.1 R7 1/1/2055 I Joists (2 Story BCI ��R-1336 Install N/A per manufacturers recommended requirements. Only) 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321802-3591 www.abdesigngroup.com AA #: 0003325 W co W U W W � o a 0 a Z O q u r Y 0 Q � 6l h 2 SU BDIV. & LOT: ST LUCIE COUNTY MASTER PA IM ROJECT#L ODEEXPRESS SHINGLE AAGE SWING: AGE: %�60 MPH EXP. C FMICHAEL TECT FLORIDA 2021* 1 NDERSON 17305 PRINT 03.30.21 DATE: SCALE: 1 /4" =1' - 0" SHEET P A I CONTROL DATE 33021