HomeMy WebLinkAboutALUMINUM SCREENREVISIONS I REV I DESCRIPTION I DATE I APPROVED 6 1 /4" PIVOT HINGE SEE NOTE 2 SHEET 2, TYP. N PIVOT HINGE SEE NOTE 2 SHEET 2, TYP. 52" MAX. FRAME WIDTH �" MAX. H dT 84„ MAX. FRAME HEIGHT 200-12 SIDE PIVOT ALUMINUM SCREEN EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING +50PSF LARGE AND SMALL MISSILE IMPACT NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. 2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL. WHERE 1 X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 4) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 5) FRAME MATERIAL: EXTRUDED ALUMINUM 6063T5 .080" THICK. SASH MATERIAL: EXTRUDED ALUMINUM 6063T5 .088" THICK. 6) SCREEN MATERIAL: .035" STAINLESS STEEL WITH 12 x12 STRANDS PER SQUARE INCH AND .048" OPEN SPACE BETWEEN STRANDS. MESH FINISH MAY BE NATURAL OR PAINTED. 7) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. TABLE OF CONTENTS 1 SHEET NO.I DESCRIPTION 1 1 2 I ELEVATIONS, ANCHORING AND NOTES 1 3 6 I INSTALLATION DETAILS 7 I COMPONENTS TAPCO NCOPPOPATE® 1815 McCULLOUGH BLVD. TUPELO, MS 38801 200 SERIES SIDE PIVOT ALUMINUM HURRICANE SCREEN — IMPACT RESISTANT SINGLE ELEVATION, ANCHORING AND NOTES DRAWN: DWG NO. TJH 08-01243 SCALE NTS DATE 04/26/1 1 1 SHEET 1 OF 7 SIGNED: 0412712011 ow i i ilr ri// R • L 0 �••ti�G�rVly •s *' 0cr t • • (�Ir rp =yo , TAT 0 F �• RED .•:�L�RID�:• N�`�= j40nALIEa����. r��tt REVISIONS I REV I DESCRIPTION I DATE I APPROVED 6 1 /4" MAX PIVOT HINGE SEE NOTE 2 SHEET 3, TYP. N PIVOT HINGE SEE NOTE 2 SHEET 3, TYP. PIVOT HINGE SEE NOTE 2 SHEET , TYP. — 52" MAX. FRAME WIDTH 1 2" MAX. 6 1 /4" MAX. O.C. SEE NOTE 3 FOR LOCKING SCREWS /4" H dT 200-13 SIDE PIVOT MULLED ALUMINUM SCREEN EXTERIOR VIEW DESIGN PRESSURE RATING IMPACT RATING +50PSF LARGE AND SMALL MISSILE IMPACT 84" MAX. FRAM E HEIGHT NOTE: 1) SINGLE WITH TRANSOM SHOWN WITH ACTIVE SASH ON BOTTOM AND FIXED SASH ON TOP. HORIZONTAL MULLED UNITS CAN BE MULLED IN ANY COMBINATION OF ACTIVE AND FIXED SASHES AS LONG AS INDIVIDUAL SASH DOES NOT EXCEED OVERALL SASH SIZE AS SHOWN HEREIN AND HORIZONTAL MULLION DOES NOT EXCEED 51 1/4". 2) PIVOT HINGES ARE LOCATED AT TOP AND BOTTOM OF EACH SASH. PIVOT HINGES ARE 01 /4" x 2 1 /2" 3) INSTALL LOCKING SCREWS #10x1 1/2" AT FIXED SASH AS FOLLOWS: 6" FROM EACH SASH END AND ONE MORE AT CENTER OF SASH. TAPCO NCOPPOPATE® 1815 McCULLOUGH BLVD. TUPELO, MS 38801 200 SERIES SIDE PIVOT ALUMINUM HURRICANE SCREEN — IMPACT RESISTANT SINGLE ELEVATION, ANCHORING AND NOTES DRAWN: DWG NO. TJH 08-01243 SCALE NTS DATE 04/26/1 1 1 SHEET OF 7 R • L 0 �••ti�G�rVly •s *' o t • • (�Ir =yo , rar OF �• RED .•:�LORID�:• j40nALIEa����. r��tt REVISIONS I REV I DESCRIPTION I DATE I APPROVED ANCHORING NOTES: 1) SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1 /4" MAX. 1 1 /2" MIN. 1 /1 6" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM EMBEDMENT 2X BUCK/WOOD FRAMING SHIM STACK TO BE 1 /4". BY OTHERS, 2X BUCK TO 2) FOR ANCHORING INTO MASONRY USE 3/16" ELCO #8 WOOD SCREW BE PROPERLY SECURED ULTRACON TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1 /4" MINIMUM EMBEDMENT INTO BUSHING WITH SUBSTRATE WITH 1 3/4'' MINIMUM EDGE DISTANCE. 01 /4" x 2 1 /2" 2X BUCK/WOOD FRAMING LOCATEINSTALLTON ORS AS SHOWN IN ELEVATIONS AND PIVOT PIN � � BY OTHERS, 2X BUCK TO BE PROPERLY SECURED 3) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/16" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 4) FOR ANCHORING INTO 16GA. MINIMUM STEEL STUD EXTERIOR FACE FRAMING USE #8 TEK SCREW WITH SUFFICIENT LENGTH OF GLAZING 1 BED MIN.IN EXTERIOR FACE TO ACHIEVE 3-THREAD PITCH MINIMUM BEYOND EMBEDMENT SUBSTRATE. LOCATE ANCHORS AS SHOWN IN OF GLAZING 1 1 /2" MIN. SEPARATION ELEVATIONS AND INSTALLATION DETAILS. FROM GLAZING 5) FOR ANCHORING INTO 1" x 1 1 /4" x 1 /8" THICK SEPARATION 1 1/2" MIN. / MAX. INTERIOR WALL MINIMUM ALUMINUM 6063-T6 TUBE FRAMING � SHIM FROM GLAZING #8 WOOD SCREW USE #10 TEK SCREW WITH SUFFICIENT LENGTH TO ACHIEVE 3-THREAD PITCH MINIMUM BEYOND SUBSTRATE. LOCATE ANCHORS AS SHOWN IN EXTERIOR INTERIOR ELEVATIONS AND INSTALLATION DETAILS. j EXTERIOR 6) ALL FASTENERS TO BE CORROSION RESISTANT. BUSHING WITH 7) INSTALLATION ANCHORS SHALL BE INSTALLED IN BUSHING WITH 01/4" x 2 1/2" HORIZONTAL CROSS SECTION ACCORDANCE WITH ANCHOR MANUFACTURER'S PIVOT PIN INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT 0 1 /4" x 2 1 /2" 2X BUCK/WOOD FRAMING INSTALLATION BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN PIVOT PIN ACTIVESASHSHOWN, FIXED THE MINIMUM STRENGTH SPECIFIED BELOW: SASH SIMILAR A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF #8 WOOD SCREW 2X BUCK/WOOD FRAMING 3,200 PSI. BY OTHERS, 2X BUCK TO C. MASONRY - STRENGTH CONFORMANCE TO ASTM 1 /4" MAX. 1 1 /2" MIN. BE PROPERLY SECURED SHIM EMBEDMENT C-90, GRADE N, TYPE 1 (OR GREATER). D. STEEL STUD FRAMING - 16GA. MINIMUM. E. ALUMINUM TUBE FRAMING 6063T6 1" x 1 1 /4" VERTICAL CROSS SECTION x 1 /8" MINIMUM WALL. 2X BUCK/WOOD FRAMING INSTALLATION SINGLE SCREEN SHOWN, MULLED �� SCREEN SIMILAR T R C O D I� C R R O R T E D ���� �I/� 1815 McCULLOUGH BLVD. �ti\S .R�• - ' 'V f/ TUPELO, MS 38801 ��v •y�GENs q(p INTS 00 SERIES SIDE PIVOT ALUMINUM *■ p $q * �_ ICANE SCREEN — IMPACT RESISTANT • INSTALLATION DETAILS O�w TAT QF .��� DWG N0. REV��n DATE 08 SHEET ��iLr7S�0IVALIEaw`� 04/28/11 3 OF 7 REVISIONS I REV I DESCRIPTION I DATE I APPROVED 2 1 /2" MIN. EDGE DIST. a 0 0 0 ooa EXTERIOR FINISH o BY OTHERS 0 0 MASONRY/CONCRETE BY OTHERS #10 TEK SCREW rEXTERIORFACE BUSHING WITH 0 1 /4" x 2 1 /2" PIVOT PIN 3/16" ELCO ULTRACON TAPCON, 3" FROM ENDS AND 12" MAXIMUM O.C. a 0 1 1 /4" MIN. EMBEDMENT d 1" x 1 1 /4" x 1 /8" 6063—T6 ALUMINUM 3—THREAD PITCH MIN. BEYOND SUBSTRATE OF GLAZING 1 1 /2" MIN. SEPARATION FROM GLAZING EXTERIOR INTERIOR BUSHING WITH 0 1 /4" x 2 1 /2" PIVOT PIN #10 TEN SCREW MASONRY/CONCRETE BY OTHERS 3—THREAD PITCH MIN. BEYOND SUBSTRATE 1" x 1 1 /4" x 1 /8" 6063—T6 ALUMINUM __r ° p 1 1 /4" MIN. a EMBEDMENT v p ° EXTERIOR FINISH v p BY OTHERS 3/16" ELCO ULTRACON 2 1 /2" MIN. TAPCON, 3" FROM ENDS EDGE DIST. AND 12" MAXIMUM O.C. VERTICAL CROSS SECTION ALUMINUM TUBE FRAMING INSTALLATION SINGLE SCREEN SHOWN, MULLED SCREEN SIMILAR 1 1 /4" MIN. EMBEDMENT 3/16" ELCO ULTRACON TAPCON, 3" FROM ENDS a AND 12" MAXIMUM O.C. d a d d 2 1/2" MIN. EDGE DIST. Q d d a MASONRY/CONCRETE BY OTHERS BUSHING WITH EXTERIOR FINISH 41 /4" x 2 1 /2" BY OTHERS PIVOT PIN 1" x 1 1 /4" x 1 /8" 6063T6 ALUMINUM EXTERIOR FACE #10 TEK SCREW OF GLAZING 1 1 /2" MIN. SEPARATION 3—THREAD PITCH MIN. FROM GLAZING BEYOND SUBSTRATE INTERIOR uF I EXTERIOR HORIZONTAL CROSS SECTION ALUMINUM TUBE FRAMING INSTALLATION SINGLE SCREEN SHOWN, MULLED SCREEN SIMILAR TAECO NCOEPOEATED 1815 McCULLOUGH BLVD. TUPELO, MS 38801 200 SERIES SIDE PIVOT ALUMINUM HURRICANE SCREEN — IMPACT RESISTANT INSTALLATION DETAILS DRAWN: DWG NO. TJH 08-01243 SCALE NTS DATE 04/28/11 1 SHEET OF 7 owl R • L D ��// �'••y����s •cP *• 0f�45t • rp _.A , TAT o F REV :�z�.S ;�L R �i�rs'nNALIEa����