HomeMy WebLinkAboutPROJECT INFORMATIONREPLACE UULA"( IANLJ 11 U C L I UM 1 J 1N 1 UY C N I fVl7 UryLT.
NEW DOOR & SIDELIGHTS TO BE IMPACT RESISTANT -
SHUTTERS NOT REQUIRED
OPENING
PRODUCT
DESIGN
OPENING
SQ
I
WIND
PRESSURES
APPROVAL
PRESSURES
COMMENTS
NO V11DTH HGT.
FTG.
ZONE
POS NEG
(N.O.A. #)
POS NEG
1 69---T 80
38.33
4
42.fi -45 5
FL16094 1
50 0 -50 0
FRONT ENTRY - LSMI
REPLACE EXISTING DOOR & SIDELIGHTS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOOR & SIDELIGHTS.
NO CHANGE IN SIZE, NO MODIFICATION TO OPENINGS
ALL DOOR & SIDELIGHT FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH MINIMUM 114" TAPCON SCREWS INTO CONCRET
WITH A MINIMUM 1 114" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS.
LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING EXEMPT FROM 2020 ENERGY CONSERVATION CODE
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 12 FT 11 IN
HALLMAN RESIDENCE
61 AQUA RA DRIVE
DOOR REPLACEMENT PLAN
JENSEN BEACH. FLORIDA