HomeMy WebLinkAboutAPPROVED, REVISION Skylight for lakes NOA~ NOTICE OF PRODUCT CERTIFICATION
A.
CE M%4
is L
T � CERTIFICATION NO: NI015149
® DATE: 01/26/2021
CERTIFICATION PROGRAM: Structural
COMPANY: Sun-Tek
f `E•+IE:tiT%s` CODE: 225-1
AEU PRO��
1'ovcril}• that tile "Notice ofProduct Certification" is valid, pleasevisitto assure that the
Product isactive and currently Hsted.This certification represents productconlbrinitytothe applicablespecificationand
Ihat cenificatiwt cri feria has been satisfied. A NAMI approved ce lifica6on label must be applied to the product to claim
certification status. Please rcvicxv and advise NAMI W any corrections are required to this document.
COMPANY NAME AND ADDRESS
PRODUCT DESCRIPTION
Sun-Tek Manufacturing, Inc.
Series "ICMG III'
10303 General Drive
Insulated Glass Skylight
Orlando, FL 32824
w/Laminated Glass (Impact)
Configuration: o
Glazing: 10-1/8" Tempered Glass11/8" Annealed
Glass/0.090" Kuraray Bulacitc PVB Interiayer/1/8"
Annealed Glass
Frame: W-1295mm(5I") 11-1295mm(51")
DLO: W-1162mm(45.75") 11-1162mm(45.75")
SPECIFICATION
PRODUCT RATING
TAS 20I/202/203-94
Design Pressure: 12873 Pa (60 psf)
1►'utcr Nenctr:diun Resistance Test Pressure: 720 Pa (ISAJ psi)
Large Missile Impact Rated
Product Tested By: National Certified Testing Laboratories
Report No: NCTL-210-4188-01
Expiration Date: August 31, 2024
Adininisirator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington IVlenrorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
J & L Wells Consulting LLC
1453 Arbitus Circle
Oviedo, FL 32765
Phone (407) 496-5489
Fax (407) 699-7789
E-mail: jdwellsjrpe@cfl.rr.corn
Product Evaluation Report
Date: March 9, 2021
Product Manufacturer:
Sun-Tek Manufacturing, Inc.
10303 General Dr.
Orlando, Fl. 32725
(407) 859-2117
Product Narne: ICMG III (Impact) Aluminum Glass Skylight
Product Category: Skylights
Product Sub -Category: Skylights
Product Approval Method: Rule 61 G20-3.005 Method 1(a) — Certification Mark or Listing
Prepared By:
uttrlf1u1,'' �"
��`� ��
James D.. Wells, Jr. P.E.
��••�,
IC E NSF•'
Florida P.E. License Number 53616
,.���5•'� :`s
J & L Wells Consulting, LLC (J & L)
1 o. 53616 ' * =
FBPE Certification of Authorization No. 27162
'k2
3! OF
J & L Project No. 220271
"s -4 . ATE
J & L Report No. 2020-001
G�V_
4flllillll�41��
Certificate of Independence
J & L Wells Consulting, LLC and James D. Wells, Jr. P.E. do not have nor will acquire financial
interest in the company manufacturing or distributing the product or in any other entity involved
in the approval process of the product named herein.
J & L Wells Consulting, LLC James D. Wells, Jr.
J & L Project No. 220271 FL 53616
Product Evaluation Report No. 2020-001 Pace l of 6
Scope
This is a Product Evaluation Report issued by James D. Wells, Jr., P.E,
Tek Manufacturing, Inc. based on Product Approval Rule 61G20- 005 Methodf Ira ttn
Certification Mark or Listing of the State of Florida Product Approval, Department) of
Community Affairs — Florida Building Commission.
This product has been evaluated for compliance to the Ph Edition (2020) Florida Building Code
(2020 FBC) and (2020) Florida Residential Code (2020 FRC) including the High Velocity
Hurricane Zone (HVHZ) sections of the code. This evaluation is not an endorsement of this
Product or a recommendation for the specific use of this product.
Descri lion of Product
See Installation Detail Instructions dated January 22, 2021 by Jaynes D. Wells, Jr. P.E. (FL #
53616) (Reference I) for a description of the product, its installation and other pertinent data
related to its use.
Installation Requirements
This product is to be installed as per the manufacturers Installation Detail Instructions (Reference
1) dated January 22, 2021 signed and sealed by James D. Wells, Jr. P.E., (FL # 53616).
Installation instructions have been verified to the test reports NCTL-2104198-lA and NCTL-
2104189-1 dated September 15, 2020 (Reference 2) and supported by Anchor Calculations
dated January 22, 2021, by James D. Wells, Jr. P.E. (Reference 3).
Code Conformance
This product has been evaluated and is in compliance with the 2020 FBC and 2020 FRC, High
Velocity Hurricane Zone (HVHZ).
Where approved for use in areas requiring wind boat debris protection, this product complies
with Section 1609.1.2 of the 2020 FBC and R301.2.1.2 of the 2020 FRC and does not require
Wind Bourne Debris Protection. This product meets missile level "D" and includes Wind Zone
4 as defined in ASTM E1996 and TA 201.
This product meets the water infiltration requirements for HVHZ.
J & L Wells Consulting. LLC James D, Wells, Jr.
J & L Project No. 220271 FL No. 53616
Product Evaluation Report No. 2020-001 Page 2 of 6
Testing and Labeling
Section 2405.5 - Unit Skylights and Tubular Daylighting Devices
R308.6.9 Testing and Labeling
Skylight shall be tested and labeled.
Testin / Margin of Safe / Design Pressure Ratin
Design Pressure Rating 60 PSF positive, 60 PSF negative.
Exterior Skylights shall be tested for conformance to the 2020 FBC and 2020 FRC in accordance
with the following:
1. Exterior Skylights shall be tested for air infiltration, water penetration and static wind
loading in accordance with 1709.6 (refers to Chapter 24 FBC) of the 2020 FBC and
per TAS 202 for conformance to the HVHZ, WBDR and areas not requiring opening
protection.
2. Impact and Cyclic Wind Pressure Loading shall be tested in accordance with the
following per TAS 201 and TAS 203 for conformance to the HVHZ and WBDR.
a. Sections 1609.1.2, 1626.1 and 1626.2 of the 2020 FBC and
b. Sections R301.2.1.2 and R4403 (refers to Chapter 16 FBC) of the 2020 FRC
This product does not meet Risk Category IV, essential facility buildings or structures,
requirements of Section 1604.5.
Reference 2 documents testing to: TAS 201-94, TAS 202-94, TAS 203-94,
AAMA/WDMA/CSA 101/I.S.2/A440-08/11/17, and ASTM E1886-05 & ASTM 131996-05/09
(WZ4) in accordance with the above.
Reference 2 documents testing the Curb Mounted Skylight to the following test pressures:
1. Uniform Load Structural Test Pressures where +120/-120 psf (Paragraph 9.3.4.3)
2. Water Test Pressure of +15 psf (Paragraph 9.3.3)
3. Cyclic Wind Loading Pressure of+/-60 psf (Table 1, ASTM E 1996-05/09)
Apply the following factors to arrive at Design Pressure:
1. A Safety Factor of 2 (2020 FBC, Sections 1504.9 and 1523.4) applied to the Uniform
Load Structural Test Pressures to arrive at Design Pressures of +60/-60 psf.
2. A factor of 1/0.15 = 6.67 applied to the Water Test Pressure to arrive at Design
Pressure of +60 psf.
Therefore, the Overall Design Pressure is +/-60 psf.
J & L Wells Consulting, LLC James D. Wells, Jr.
J& L Project No. 220271 FL No. 53616
Product Evaluation Report No. 2020-001 Page 3 of 6
N
N 1--
l � ON
NOTICE OF PRODUCT CERTIFICATION immmm
�� Ct:RT1�k.4
A�
4.1c �i,A(Ckf�'r
CERTIFICATION NO: N1015149
x DATE: 01/26/2021
d CERTIFICATION PROGRAM: Structural
41 fi COMPANY: Sun-Tek
ieE ttF`rr+rs` CODE: 225-1
f7ED PIR
To verify that the "Notice of Product Certification" is valid, please visit +++v+,.N \MICcrtilication cnm to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
III atcertification criterialias been satistied. ANAMlapproved certificationlabel Must beappliedtothe product toclaim
certif-IC36011 status. Please review and advise NAM if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
Sun-Tek Manufacturing, Inc. Series "ICMG III"
10303 General Drive Insulated Glass Skylight
Orlando, FL 32824 W/Laminated Glass (Impact)
Configuration: 0
Glazing: 1G-1/8" Tempered Glass/ 1/8" Annealed
Glass10.090" Kura -ay Butacite PVB Interlayer/l/8"
Annealed Glass
Frame: W-1295mm(51") I1-1295mm(ji")
DLO: W-1162mm(45.75") 11-1162mm(45.75")
SPECIFICATION PRODUCT RATING
TAS 201/2021203-94 Design Pressure: ±2873 Pa (60 psi)
Water Penetration Resistance Test Pressure: m Pu (1swu pt)
Large Missile Impact Rated
Product Tested BY: National Certirted Testing Laboratories
Report No. NCTL-210-4188-01
Expiration Date: August 31, 2024
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Higlt►vay
Hayes, VA 23072
Tel: (804) 684-5124
Fax. (804) 684-5122