Loading...
HomeMy WebLinkAboutAPPROVED FL8784.1 - Picture Windows 1CERTIFICATION NO: NI008088.01-R9 DATE: 06/03/2007 CERTIFICATION PROGRAM: Structural COMPANY: WiWinTech CODE: 583-1 REVISION DATE: 04/03/2019 To verify that the “Notice of Product Certification” is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION ViWinTech Windows and Doors Series “SL 3100 i PW 7872" Impact 2400 Irvin Cobb Drive Rated Vinyl Fixed Prime Window Paducah, KY 42003-0588 Configuration: O (Fin Mount) Glazing: IG-3/16" Annealed Glass/Laminate-3/16" Annealed Glass/0.090" DuPont Sentryglas® Plus/3/16" Annealed Glass Frame: W-1980mm(78") H-1830mm(72") DLO: W-1835mm(72.25") H-1690mm(66.5") SPECIFICATION PRODUCT RATING AAMA/WDMA/CSA 101/I.S.2/A440-05 TAS 201/202/203-94 FW-R60 1980 x 1830 (78 x 72) Design Pressure: +60/-60 psf Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories, Inc. Report No: NCTL-110-10728-27/110-10728-25 Expiration Date:May 31, 2023 Administrator’s Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: NI008088.02-R9 DATE: 06/03/2007 CERTIFICATION PROGRAM: Structural COMPANY: WiWinTech CODE: 583-1 REVISION DATE: 04/03/2019 To verify that the “Notice of Product Certification” is valid, please visit www.NAMICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION ViWinTech Windows and Doors Series “SL 3100 i PW 7872" Impact 2400 Irvin Cobb Drive Rated Vinyl Fixed Prime Window Paducah, KY 42003-0588 Configuration: O (Flush Mount) Glazing: IG-3/16" Annealed Glass/Laminate-3/16" Annealed Glass/0.090" DuPont Sentryglas® Plus/3/16" Annealed Glass Frame: W-1980mm(78") H-1830mm(72") DLO: W-1835mm(72.25") H-1690mm(66.5") SPECIFICATION PRODUCT RATING AAMA/WDMA/CSA 101/I.S.2/A440-05 TAS 201/202/203-94 FW-R60 1980 x 1830 (78 x 72) Design Pressure: +60/-60 psf Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories, Inc. Report No: NCTL-110-10728-27/110-10728-26 Expiration Date:May 31, 2023 Administrator’s Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 NOTICE OF PRODUCT CERTIFICATION L. Roberto Lomas P.E. 233 W. Main St Danville, VA 24541 434-688-0609 rllomas@lrlomaspe.com Manufacturer:ViWinTech Windows and Doors 2400 Irvin Cobb Dr. Paducah, KY 42003-0588 Engineering Evaluation Report Report No.: 511139-l E Product Line: SL 3100 i PW 7872 Shoreline Picture Window 3100 (78x72) Impact HVHZ Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1 (a). The product listed herein complies with requirements of the Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-00204 Revision E, prepared, signed and sealed by L. Roberto Lomas P.E. 2. Report No.: NCTL 110-10728-24, signed by Robert H. Zeiders, P.E. National Certified Testing Laboratories, York, PA. AAMA/WDMA/CSA 101/1.S.2/A440-05 (Flange installation) Design pressure: +60.Opsf Water penetration resistance 9.Opsf 3. Report No.: NCTL 110-10728-25, signed by Robert H. Zeiders, P.E. National Certified Testing Laboratories, York, PA. AAMA/WDMA/CSA 101/1.S.2/A440-05 (Fin installation) Design pressure: +60.Opsf Water penetration resistance 9.Opsf 4. Report No.: NCTL 110-10728-26, signed by Robert H. Zeiders, P.E. National Certified Testing Laboratories, York, PA. AAMA/WDMA/CSA 101/1.S.2/A440-05 (Flush installation) Design pressure: +60.Opsf Water penetration resistance 9.Opsf 5. Report No.: NCTL 110-10728-27, signed by Robert H. Zeiders, P.E. National Certified Testing Laboratories, York, PA. Flange, fin and flush installation TAS 201-94 Large Missile Impact Test TAS 202-94 Uniform Static Air Pressure, +60.Opsf design pressure, 9.Opsf water penetration. TAS 203-94 Cyclic Pressure loading +60.Opsf design pressure 6. Anchor calculations, report number 511140-1, prepared, signed and sealed by L. Roberto Lomas P.E. Limitations and Conditions of use: • Maximum design pressure:+60.Opsf • Maximum unit size:78" x 72" • Units must be glazed per ASTM E1300-04, refer to approval document for glazing details. • This product is rated to be used in the HVHZ. • This product is impact resistant and does not require impact protection in wind borne debris regions. • Frame material to be rigid PVC. Installation:Units must be installed in accordance with manufacturer's installation instructions and approval document, 08-00204, Revision E. Certification of Independence:Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). 1 of 1 4\31:141.:,1./4/4. f<2<>GEN;..ld'1-e. s2 *" ,#1(100625 '· * 2 ** S,ATE OF *.05<328' * :L OR \01: ..'dr.S..- G44-8/OAL E"///////111\\\\\\ Luis R. Lomas, P.E. FL No.: 62514 10/29/2015