HomeMy WebLinkAboutAPPROVED FL9333.2 - DOUBLE HUNG WINDOWS 24/5/2021 Florida Building Code Online
1 Business& Professional Regulation ML
9CtS Home I Log In I User Registration Hut Twits Submit Surcharge state & Facts Pubii[atf°n5 Contact LA RCIS Site Map Links Search
db'prIP ER: Pub Approval
USER: Public user
Product Approval Menu Search > Appiicaugn List � Appllcatlon H1stM a Application Detail
FL # FL9333-R14
Application Type Revision
Code Version 2020
Application Status Approved
Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Small
Authorized Signature
Technical Representative
Address/ Ph one/Ern a l l
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
VI Win Tech
2 300 Irvin Cobb Drive
Paducah, KY 42003
(270) 538-4431
swhecier@Viwintech.com
Steven Wheeler
Swheeler@viwintech, com
Steve Wheeler
2400 Irvin Cobb Dr
Paducah, KY 42003
(270)538-4431
swheeler@viwi ntech.com
Ronnie WIlllams
2400 Irvin Cobb Dr
Paducah, KY 42003
(270) 538-4437
rwilliams@viwlntech.com
Windows
Double Hung
Certification Mark or Listing
National Accreditation & Management Institute
Scott Waiters, PE
Validation Checklist - Hardcopy Received
Standard
AAMA/ W DMA/CSA/ 101.1/I,S,S/A440
ASTM E1886-13a
ASTM E1996-14a
TAS 201/202/203
Florida Licensed Professional Engineer or Architect
FL9333 R14 Eauiv FL9333 Equivaiency_p ff
Year
2008
2013
2014
1994
https:llwww.floridabuilding.org/prlpr app_dtl.aspx7param=wGEVXQwtDgt%2fAIdUdyTLMaF3d8B7QskeTLR(IObTNJ4yEuGwUUFb0/u2bEw%3d%3d 1/2
4/5/2021 Florida Building Code Online
Product Approval Method Method L Option A
Date Submitted 12/30/2020
Date Validated 12/31/2020
Date Pending FBC Approval
Date Approved 01108/2021
Summary of Products
FL #
Model, Number or Name
Description
9333.1
5100 OH Nan -Impact HVHZ
5100 DH Non -Impact HVHZ 52 x 75
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: No
Certification Agency Certificate
FL9333 R14 C CAC NI010803-R4,pdf
Quality Assurance Contract Expiration Date
08/3112023
Design Pressure: +60/-60
Installation Instructions
Other: GLASS COMPLIES WITH ASTM E1300-04. FRAME
MATERIAL TO BE RIGID PVC FROM VISION EXTRUSIONS LTD.
FL9333 R14 II 08-01317C.pdf
Verified By: Luis Roberto Lomas 62514
AAMA CERTIFIED (VEX-1).
Created by Independent Third Party: Yes
Evaluation Reports
FL9333 R14 AE 511926D.pdf
Created by Independent Third Party: Yes
9333.2
SL 5100 i DH 5275
Shoreune 5100 Double Hung Window, Impact Rated, 52 x 75.
H-1170, lamb install method.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: Yes
Certification Agency Certificate
FL9333 R14 C CAC NI008081-118 pI ff
Quality Assurance Contract Expiration pate
04/30/2023
Design Pressure: +70/-70
Other: When used in HVHZ color of frames to be WHITF only
rigid PVC. GLASS COMPLIES WITH ASTM E1300-04, FRAME
MATERIAL TO BE RIGID PVC FROM VISION EXTRUSIONS LTD,
AAMA CERTIFIED (VEX-1)."NOT TO BE INSTALLED 30' OR
HIGHFR ABOVE GROUND LEVEL" - GLASS INTERLAYER
COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA
BUILDING CODE ACCORDING TO MIAMI-DADE NOA FOR
Installation Instructions
EL9333 R14 11 08-002 6E 51 OODH IMP I stal .pdf
Verified By: Luis R. Lomas, P.E. 62514
Created by Independent Third Party: Yes
Evaluation Reports
FL933R14 AE 510926F - 510ODH IMP Evaluation.pdf
Created by Independent Third Party: Yes
kURARAY INTEPLAYERS - "Safety Class on outside pane
required in HVHZ zones"
Contact Us :: 26 1 Blair Stone RO,1d, Tall2has5ee I L 32399 Phone; 850-487-1824
The State or Flanda is an AA/FFO emplayer. Ca�y_nght 2007-2013 State of Florida.:: PrivaV. Statement :: ArcessiblliN Statement ;: Refund Statement
Under Flodda law, email addresses are public records. If you do not want your a -mall address released In re5p0nse to a public-rerords request, du not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questinns, please contact 850.487.1395. Vursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the ❑epartment with an email address If they have one. The emalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide tht Department with an email address which can be made available to the public. To determine It you are a licensee under Chapter 455, F.S., please click here ,
Product Approval Accepts -
IT 0] ® eC recto M
Credit Cara
Safe
https:liwww.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgt%2fAlclUdyTLMaF3d8B7QskoTLROObTNJ4yEuGwUUFb%2bEw`/a3da/e3d 212
NOTICE OF PROD [,i CT CERTIFICATION
il4 GERTIFjC4T'
Q iV i
cF � . %'eJ
�P+eo �oo1
CERTIFICATION NO:
DATE:
CERTIFICATION PROGRAV:
COMPANY:
CODE:
REVISION DATE:
N1008081-118
06/03/2007
Structural
WiWinTech
583-1
04/03/2019
To verify that the "Notice of Product Certification" is valid, please visit www_NAMICertification.com to assure that the
product is active and currently listed. This certification represents product conformity, to the applicable specification and
that certification criteria has been satisfied, A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
ViWinTech Windows and Doors Series "SL 5100 i DH 5275" Tilt Impact
2400 Irvin Cobb Drive Rated Vinyl Double Bung Prime Window
Paducah, KY 42003-0588 Configuration: X/x
Glazing: [G-1/8" Annealed Glass/Larninate-1/8"
Annealed Glass/0.090"DuPont Butacitegi PVC/
1/8" Annealed ('class
Frame: W-1320mm(52") H-1900mm(75")
Sash: W-1250mm(49.25") 1I-930mm(36.63")
SPECIFICATION
PRODUCT RATING
AAMA/WDMA/CSA 101/1.S.2/A440-05 H-R70 1320 x 1900 (52 x 75)
ASTM E I 886-05/E 1996-04 Wind Zone 4-Missile Level D
TAS 201/202/203-94 Design Pressure: +70/-70 psf
Large Missile Impact Rated
Product Tested By: National Certified Testing Laboratories, Inc.
Report No: NCTL-1 10-10728-L/110-10728-2/110-10728-3
Expiration Date: April 30, 2023
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
L. Roberto Lomas P.E.
1432 Woodlord Rd
Lewisville, NC 27023
434-688-0609
Manufacturer: Viwintech
2400 Irvin Cobb Drive
Paducah, KY 42003-0588
Product Line: Shoreline Double Hung 5100 - Impact
Engineering Evaluation Report
Report No.: 51O926F
Compliance:
The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of
Business and Professional Regulation for Statewide Acceptance per Rule 61G20-3.005 method 1(a). The product listed
herein complies with requirements of the Florida Building Code.
Supporting Technical Documentation:
i. Approval document: drawing number 08-00206, revision E, prepared, signed and sealed by L. Roberto Lomas P.E.
2. Test report No_ NCTL-110-10728-1 signed and sealed by Robert H. Zeiders, P.E.
National Certified Testing Laboratories, York, PA
AAMAM/DMA/CASA 10111.S.21A440-05
Design pressure: ±70.0 psf
Water penetration resistance 10.5 psf
3. Test report No. NCTL-110-10728-2 signed and sealed by Robert H. Zeiders, P.E.
National Certified Testing Laboratories, York, PA
ASTM E1886-05 and ASTM E1996-04
ASTM E1886/ E1996 Large Missile Impact, Level D, Wind Zone 4
ASTM E18861 E1996 Cyclic Load Test, ±70.0 psf design pressure
4. Test report No.: NCTL-110-10728-3 signed and sealed by Robert H. Zoiders, P.E.
National Certified Testing Laboratories, York, PA
TAS 201-94 Large Missile Impact Test
TAS 202-94 Uniform Static Air Pressure, ±70.0 psf design pressure, 10.5 psf water penetration.
TAS 203-94 Cyclic Pressure loading ±70.0 psf design pressure
5. Anchor calculations, report number 510291 D. prepared, signed and sealed by L. Roberto Lomas P.E,
Limitations and Conditions of use:
• Maximum design pressure: ±70.0 psf
• Maximum unit size: 52" x 75"
• Maximum D.L.O.: 44 112" x 29 1/2"
• Units must be glazed per ASTM El300-04109 according with installation details in approval drawing.
• This product is rated to be used in the HVHZ.
• This product is impact resistant and does not require impact protection in wind bome debris regions.
• Frame material to be white rigid PVC.
Installation:
Units must be installed in accordance with manufacturer's installation instructions and approval document, 08-00206
revision E.
Certification of Independence:
Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the
product(s) for which this report is being issued_ Also, I don't have nor will acquire a
financial interest in any other entity involved in the approval process of the listed
product(s).
1 of 1
*` 00
•'c10.
0RVOt •
s•-...-
S10NAL���`�
f�/111111111�\
Luis R. Lomas, P.E.
FL No.: 62514
12126/2017
NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL.
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE
ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL.
5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY
FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF
THE ARCHITECT OR ENGINEER OF RECORD.
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
8. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD
BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE
SHIM STACK TO BE 1/4".
9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS.
11. FRAME MATERIAL: EXTRUDED RIGID PVC.
12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, SEE SHEET 2 FOR GLASS DETAILS.
13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14,FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO
SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
REVISIONS
DESCRIPTION DATE APPROVED
REVISED PER NEW REQUIREMENTS 12/26/17 R.L.
15.FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2
1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND
INSTALLATION DETAILS.
16. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF
DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND
STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
DETAILS.
17. ALL FASTENERS TO BE CORROSION RESISTANT.
18. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI.
C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH f'm=2,000PSI MINIMUM.
D. METAL STRUCTURE: STEEL 18GA (.048") FY=33KS1/FU=52KSI OR
ALUMINUM 6063-T5 FU-30KSI 1/8" THICK MINIMUM
TABLE OF CONTENTS 1
SHEET NO. DESCRIPTION
1 NOTES
2 ELEVATION & GLAZING DETAIL
3 - 8 INSTALLATION DETAILS
SIGNED: 1212712017
v W N TECH AND DOORS
L,6����/'/
2400 IRV NDOWS COBB
`\\\J`y1�P,
PADUCAH, KY 42003
v.•�\G�Ns�9� i
0y� 61 *�
SHORELINE DOUBLE HUNG WINDOW 5100*�•/�
52" X 75" IMPACT HVHZ
,pvL�gb( C?�
it
NOTES$TAT
EE OF
A.
/;P ZORIV � G\
DRAWN:
DWG N0.
REV
08 s00206
E
���
'���sl��Ai.`�a\\��
Luis R. Lomas P.E.
FL No.: 62514
SCALE NTS DATE 07/25/07
HEET 1 OF 8
L. ROBERTO LOMAS P.E.
1432 WOODFORD RD LEWISVILLE, PIC 27023
434-688-0609 rllomaS@Irlomaspe.Com
7
M
FR
HE
52" MAX FRAME WIDTH
13
6" MAX MAX10.C. 6" MAX
l
6" MAX
12 3/4"
vvv
MAX O.C.
/
5"
4X
WE
GHT
6" MAX
DESIGN PRESSURE RATING
IMPACT RATING
+70.OPSF
LARGE
MISSILE IMPACT
52" X 75" UNIT SHOWN. OTHER SIZES APPROVED AS LONG AS
FRAME AREA DOES NOT EXCEED 27.1 FT2
REVISIONS
REV DESCRIPTION DATE APPROVED
E REVISED PER NEW REQUIREMENTS 12/26/17 R.L.
/8"
1/8" ANN
1/8" ANN 090" PVB BY KURARAY
XL EDGE SPACER 1/8" ANN
201 STAINLESS STEEL
DESICCANT FILLED
BY CARDINAL
EXTERIOR I
INTERIOR
5/8
DOW 995
SEALANT
SETTING BLOCK
12B11-00110 BY LAMATEK
ECO PVC 85 DUROMETER
VIWIN TECH WINDOWS AND DOORS
2400 IRVIN COBB DRIVE
PADUCAH, KY 42003
SHORELINE DOUBLE HUNG WINDOW 5100
52" X 75" IMPACT HVHZ
ELEVATION
DRAWN: DWG NO.
R.L. 08-00206
SCALE NTS IDATE 07/25/07 SHEET OF 8
L. ROBERTO LOMAS P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023
434-688-0609 rllomas@lrlomaspe.com
SIGNED: 1212712017
`\\\J011P1 l I IL o
STATE OF
REv
E/SfONAI `�a����
Luis R. Lomas P.E.
FL No.: 62514
WOOD FRAMING
OR 2X BUCK
BY OTHERS
BACKER ROD
& APPROVED
SEALANT
EXTERIOR
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
" MIN.
DISTANCE
MIN.
VENT
MAX.
SPACE
) WOOD SCREW
INTERIOR
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
4" MAX.
M SPACE
REVISIONS
DESCRIPTION DATE APPROVED
REVISED PER NEW REQUIREMENTS 12/26/17 R.L.
1 1/4" MIN. 1/4" MAX.
EMBEDMENT SHIM SPACE
INTERIOR
1/2" MIN. 0 ^�
EDGE DISTANCE Y F=AMOG01
#10 WOOD
SCREW
O O
WOOD FRAMING
OR 2X BUCK
BY OTHERSAl
o -
BACKER ROD
& APPROVED
SEALANT EXTERIOR
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
NOTES:
1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
SIGNED: 1212712017
vIW N TECH D DOORS
11 l I IL
2400 IRVIN COWS BB DRIVE
'///'/
PADUCAH, KY 42003
v.•�\G�Ns�9� i
SHORELINE DOUBLE HUNG WINDOW 5100*�•/�
0y� 61 *�
5 X IMPACT
,pvL�gbTM
INSTALLATION DETAILS
IN DETAILS
INSTALLATION
��0 , $TATEE OF
0
DRAWN: DWG NO.
REV //��s pR�O ,
R.L.'SCALE
08 5002HEET
E /6�/
36 OF 8
NTS DATE 07/25/07
NAll`�a
L. ROBERTO LOMAS P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023
Luis R. Lomas P.E.
FL N o.: 6251 4
434-688-0609 rllomas@lrlomaspe.com
METAL
STRUCTURE
BY OTHERS
APPROVED
SEALANT
EXTERIOR
BACKER ROD
& APPROVED
SEALANT
METAL
STRUCTURE
BY OTHERS
3/4" MIN
EDGE DISTANCE I
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
1/4" MAX.
SHIM SPACE
0 SMS OR
LF DRILLING
REW
INTERIOR
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
1 /4" MAX.
SHIM SPACE
3/4" MIN.
EDGE DISTANCE
I
#10 SMS OR -
SELF DRILLING
SCREWS
METAL
STRUCTURE
BY OTHERS
REVISIONS
REV DESCRIPTION DATE I APPROVED
E REVISED PER NEW REQUIREMENTS 12/26/17 1 R.L.
1 /4" MAX.
SHIM SPACE
INTERIOR
BACKER ROD EXTERIOR
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
NOTES:
1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
VIWIN TECH WINDOWS AND DOORS
2400 IRVIN COBB DRIVE
PADUCAH, KY 42003
SHORELINE DOUBLE HUNG WINDOW 5100
52" X 75" IMPACT HVHZ
INSTALLATION DETAILS
DRAWN: DWG NO.
R.L. 08-00206
SCALE NITS IDATE 07/25/07 SHEET 4 OF 8
L. ROBERTO LOMAS P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023
434-688-0609 rllomas@lrlomaspe.com
SIGNED: 1212712017
`\\\J011P1 l I IL o
STATE OF
RL %�A.
'rFs<ORIOP: G1��
E sfOIVA1.10a��`�
Luis R. Lomas P.E.
FL NO.: 62514
CONCRETE/MASONRY
BY OTHERS
OPTIONAL 1X BUCK
SEE NOTES 3 - 7
SHEET 1
BACKER ROD
& APPROVED
SEALANT
EXTERIOR
2 1/2" MIN.
EDGE DISTANCE
° d °
a °
° ° d
1/4" MAX.
SHIM SPACE
1` 3/16" TAPCON
INTERIOR
REVISIONS
DESCRIPTION DATE I APPROVED
REVISED PER NEW REQUIREMENTS 12/26/17 1 R.L.
1 1/4" MIN,
EMBEDMENT
1 1/4" MIN.
1/4" MAX.
EMBEDMENT
SHIM SPACE
CONCRETE/MASONRY
BY OTHERS °
v
b°
OPTIONAL 1X BUCK
SEE NOTES 3 - 7 °
SHEET 1 -°
INTERIOR
3/16" TAPCON v
O
❑ O
o° v
2 1/2„
0 ❑ O
MIN.
EDGE
a
DISTANCE °
°
- - - -
BACKER ROD EXTERIOR
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
SILL TO BE SET
CONCRETE/MASONRYINSTALLATION
BACKER ROD
& APPROVED
IN A BED OF
APPROVED SEALANT
NOTES:
SEALANT
1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
1 /4" MAX.
NOT SHOWN FOR CLARITY.
OPTIONAL 1X BUCK
SHIM SPACE
2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
SEE NOTE 3 - 7
DESIGNED IN ACCORDANCE WITH ASTM E2112
SHEET 1
SIGNED: 1212712017
vIWN TECH WINDOWS DOORS
CONCRETE/MASONRY
�RD
`•yv"1EIN,L8o�4BYOTHERS
°
2400 IRV
°
PADUCAH, KY 42003
+
da e
d
°d
SHORELINE DOUBLE HUNG WINDOW 5100*•
•
0 61 *=
a
52" X 75" IMPACT HVHZ
—
INSTALLATION DETAILS
$TAT OF �\
VERTICAL CROSS SECTION
DRAWN: owc No.
RE
' 'r�t+` c<pRIOP•
CONCRETE/MASONRYINSTALLATION
SCALE
08 002HEET
E
/',,s/%
56 OF 8
NITS DATE 07/25/07
11�1�10aG\``
L. ROBERTO LOMAS P.E.
LUIS R. Lomas P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023
FL No.: 62514
434-688-0609 rllomas@lrlomaspe.com
WOOD FRAK
OR 2X B
BY OTH
MIN.
DISTANCE
REVISIONS
REV DESCRIPTION DATE APPROVED
E I REVISED PER NEW REQUIREMENTS 12/26/17 1 R.L.
BACKER ROD 1 1/4" MIN.
& APPROVED EMBEDMENT
SEALANT
1 MAX.
� SHIM
SPACE
a 1 1/4" MIN. 1/4" MAX.
EMBEDMENT SHIM SPACE
❑ #10 WOOD SCREW
WOOD FRAMING INTERIOR
O O OR 2X BUCK
BY OTHERS
#10 WOOD
SCREW
EXTERIOR
BACKER ROD
& APPROVED
SEALANT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
Vcn I I(iHL liIiVJJ JCIi I Ivry
WOOD FRAMING OR 2X BUCK INSTALLATION
INTERIOR
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
'4" MAX.
M SPACE
1/2" MIN. LJ o
EDGE DISTANCE 0
❑ O
BACKER ROD
& APPROVED o
SEALANT - - -
EXTERIOR
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
NOTES:
1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
VIWIN TECH WINDOWS AND DOORS
2400 IRVIN COBB DRIVE
PADUCAH, KY 42003
SHORELINE DOUBLE HUNG WINDOW 5100
52" X 75" IMPACT HVHZ
INSTALLATION DETAILS
DRAWN: I DWG NO.
R.L. 1 08-00206
SCALE NT$ IDATE 07/25/07 1 SHEET 6 OF 8
L. ROBERTO LOMAS P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023
434-688-0609 rllomas@lrlomaspe.com
SIGNED: 1212712017
`\\\J`y11�1l I IL o
STATE OF
RL 0—
G1��
E
Luis R. Lomas P.E.
FL NO.: 62514
METAL
STRUCTURE
BY OTHERS
APPROVED -
SEALANT
EXTERIOR
BACKER ROD
& APPROVED
SEALANT
METAL
STRUCTURE
BY OTHERS
3/4" MIN
EDGE DISTANCE
1/4" MAX.
SHIM SPACE
#10 SMS OR
SELF DRILLING
SCREW
INTERIOR
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
1/4" MAX.
SHIM SPACE
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
#10 SMS OR
SELF DRILLING
SCREWS
3/4" MIN.
EDGE DISTANCE
METAL
STRUCTURE
BY OTHERS
1 /4" MAX.
FSHIM SPACE
INTERIOR
L BACKER ROD
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
REVISIONS
REV DESCRIPTION DATE APPROVED
E REVISED PER NEW REQUIREMENTS 12/26/17 R.L.
EXTERIOR
NOTES:
1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
VIWIN TECH WINDOWS AND DOORS
2400 IRVIN COBB DRIVE
PADUCAH, KY 42003
SHORELINE DOUBLE HUNG WINDOW 5100
52" X 75" IMPACT HVHZ
INSTALLATION DETAILS
DRAWN: DWG NO.
R.L. 08-00206
SCALE NT$ IDATE 07/25/07 SHEET OF 8
L. ROBERTO LOMAS P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023
434-688-0609 rllomas@lrlomaspe.com
SIGNED: 1212712017
`\\\J011P1 l I IL o
STATE OF
A.
RL S ZORIT .
E
Luis R. Lomas P.E.
FL NO.: 62514
CONCRETE/MASONRY
BY OTHERS
OPTIONAL 1 X BUCK
SEE NOTES 3 — 7
SHEET 1
BACKER ROD
& APPROVED
SEALANT
EXTERI(
BACKER ROD
& APPROVED
SEALANT
OPTIONAL 1 X BUCK
SEE NOTE 3 — 7
SHEET 1
CONCRETE/MASONRY
BY OTHERS
_ 2 1/2" MIN.
EDGE DISTANCE
°a 1 1/4" MIN.
° d a
a a EMBEDMENT
d
I
1/4" MAX.
'Ia SHIM SPACE
1"— 3/16" TAPCON
INTERIOR
SILL TO BE SET
IN A BED OF
APPROVED SEALANT
1/4" MAX.
SHIM SPACE
d ° d
VERTICAL CROSS SECTION
CONCRETEIMASONRY INSTALLATION
1 1/4" MIN.
EMBEDMENT
CONCRETE/MASONRY
BY OTHERS °
OPTIONAL 1 X BUCK ° v
SEE NOTES 3 — 7 e°
SHEET 1
3/16" TAPCON
a °
o° a
2 1/2" MIN. ° c
EDGE DISTANCE
REVISIONS
REV DESCRIPTION DATE APPROVED
E REVISED PER NEW REQUIREMENTS 12/26/17 R.L.
1/4" MAX.
SHIM SPACE
BACKER ROD
& APPROVED
SEALANT
JAMB INSTALLATION DETAIL
CONCRETEMASONRY INSTALLATION
NOTES:
1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS,
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
INTERIOR
VIWIN TECH WINDOWS AND DOORS
2400 IRVIN COBB DRIVE
PADUCAH, KY 42003
SHORELINE DOUBLE HUNG WINDOW 5100
52" X 75" IMPACT HVHZ
INSTALLATION DETAILS
DRAWN: DWG NO.
R.L. 08-00206
SCALE NTS DATE 07/25/07 SHEETS OF $
L. ROBERTO LOMAS P.E.
1432 WOODFORD RD LEWISVILLE, NC 27023
434-688-0609 rllomas@lrlomaspe.com
EXTERIOR
SIGNED: 1212712017
P,1 l I IL
��; STATE OF •��
RL 'rFs <QRIOP: G1���
E '-V ONA1.00�`�
Luis R. Lomas P.E.
FL NO.: 62514