HomeMy WebLinkAbout21-214 Wolflube Formboard(esign)I
U
0
w
0
}
J_
m
LL a
� J
2 D
H D
w0
Ox
H
z�
w LU
Um
z J
OJ
U =
ZW
W
H U
�z
w p
W
CO
OZ
0
EL
�EL
0
O
�a
a 0
EL
}a
zz
ao
Oa
0N
w0
Zx
0 �
Qa
w Z
m�
ory,
w�
x ~
w0
a�
0
oz
Z w
W Z)
0
o�
Z
0O
O Ld
U
z
z
z
a J
z w
uw
0 a_0
U
ry i
02
00
W z
oa
zw
a0
x
Uw
oD
W LLI
�of
oLLJ
a <
EL
a
LUW
oEL
wa
U) Cl)
wa
�
d
U�
0 U
m=
o�
Z 0
0
aLL
�z
xW
U J
2 U
U) z
0a
O W
zU)
�IL
0 M
U) U
wLL
~w
oa
U)
U) U) W
�x
x�
0
o
>-
W J
'L Z
00
�0
d W
J �
aZ
Z) W
U Z
J
a J
O W W
Lq H U_
O Z >
0 ��
w
N ZQ
0
N LL
00=0
�w
a a �
ao�
0 Z
E J z Z
LL a
0
o0z
�w,
v > w
N � _
E 0
N O H
w w
�ryU)
U)Ww
Of
ova
a`�
�>z0
oww
}w0
wro
z
'If}
a
U) U)
OfLLI
Lu
Y W 0
Z �; U
W Q' W
L
- x
U) L H
vex
v
U Of
m z w
�UF
5Lu W
Imo
N O Z
N N W
H 2E
o = U
N 0
}0
LuaU)
-o=
N U H
GRAPHIC SCALE
50 0 25 50 100
( IN FEET )
1 inch = 50 ft.
BENCHMARK
FND NAIL &
WASHER LB 7545
EL.=19.95 (NAVD88)
4�. 50'I R=2665.00'
0=1 *01'16"
I SSMH
TOP EL=20.53
DETAIL A:
FND 5/8"
IRC LB4286
I
-o
-_
r
D o
I mJ
�
ui
I
m
I- 1 2�1-0 -
87°37'52"W
G
I
109.28'
N
U
Cry
I
A olo
I
m
m
om
I
l
Im
ID
I
NI
U�
I
o
I
I
I J107.84'
27
•
CA
I
N
I
Irn I
8
C o
m m
/
/
Ir /
-m
BENCHMARK
SET NAIL &
WASHER LB 7545
EL.=20.21(NAVD88)
FND 5/8" IRC
LB4286
S=0.30
W=0.18
200
,
in
O
wi
M
OMMERCIAL BUILDING
NDER CONSTRUCTION
FFE=21.35'
16.80' I
18.77' I
16.65' I
I
16.13'
45' 56.42'
o)
N
1.65'
0.96'
1.33'
16.80'
1.27'
0.90'
1.90'
18.77'
2.04'
1.14'
1.32'
16.65'
1.35'
1.06'
1.73'
FORMBOARD SURVEY
LOT 13
(VACANT)
S89`41'08"E 683.45'
bo LOT 14
O PARCEL ID:
0U-) 3406-502-0009-000-9
/
�e A 7 43„
(VACANT)
444.70'
435.68'
FOR: WOLFLUBE
BENCHMARK
SET NAIL &
WASHER LB 7545
EL.=19.78(NAVD88) /
FND 5/8" IRC
(NO ID)
L=151.95' R=1500.38'
A=5.48'09"
10 DE S89°41 �08-' E 6. 3280'
/ FND 5/8" IRC FND 5 LB4286
LB4286 0.17' SOUTH
GRAPHIC SCALE
20 0 10 20 40
( IN FEET )
1 inch = 20 ft.
LOT 15
(VACANT)
1
FND 4X4 CM
LB4286
ST. LUCIE COUNTY, FLORIDA
VICINITY MAP
A
SYMBOL & ABBREVIATION LEGEND:
40.0 /
AL
ARC LENGTH
SQ FT.
SQUARE FEET
PLS
PROFESSIONAL LAND
GND
GROUND
SURVEYOR
-�
BENCHMARK (BM)
R
RADIUS
j,
YYY
HYD
HYDRANT�
RGE
RANGE
(C)
CALCULATED
'
q
CENTERLINE
IR
IRON ROD
R/W
RIGHT-OF-WAY
I
CHID.
CHORD
IR/C
IRON ROD AND CAP
SO
SANITARY MANHOLE
Q a
CONC
CONCRETE
L
LENGTH
SEC
SECTION
d �J
CM
CONCRETE MONUMENT
MAG/D
MAG NAIL MAG BRAND NAIL
S
SOUTH
xi�
x a i►�
A
DELTA/CENTRAL ANGLE
NGVD29
NATIONAL GEODETIC
VERTICAL DATUM OF 1929
O
STORMWATER DRAINAGE
DO
DRAINAGE MANHOLE
N/D
NON DESCRIPT NAIL AND
MANHOLE
r
DISK
TOE
TOE OF SLOPE
E
EAST/EASTING
N.R.
NON RADIAL
TOB
TOP OF BANK/BERM
U W
A
I
EL./ELEV.
ELEVATION
NAVD88
NORTH AMERICAN VERTICAL
X 0.00
TOPOGRAPHIC DATA
a rr
FEMA
FEDERAL EMERGENCY
DATUM OF 1988
TWNSHP
TOWNSHIP
MANAGEMENT AGENCY
N
NORTH OR NORTHING
I
(M)
FIELD MEASURED
No.
NUMBER
LINK
UNKNOWN
0I O
F.F.E.
FINISHED FLOOR ELEVATION
O.R.B.
OFFICIAL RECORDS BOOK
WV >11
WATER VALVE (WV)
Cq
FPL
FLORIDA POWER AND LIGHT
PG
PAGE
o FND PK
o
NAIL
FT
FOOT
P.B.
PLAT BOOK
®
WELL
& WAS
ER
FND
FOUND
(P)
PLAT DATA
W
WEST
co LB4286
LI
IT OF PLAT
N
0
LEGAL DESCRIPTION:
C
I
40. 0'
1 I
BENCHMARK
FND NAIL &
WASHER LB 4286
EL.=18.74(NAVD88)
FAVORITE STR�ET
(50.00' PUBLIC RIGHT-OF-WAY)
(UNIMPROV D)
NO SCALE
LOT 14, MIDWAY INDUSTRIAL PARK - PHASE III - SOUTH, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT
BOOK 45, PAGE(S) 40 THROUGH 41, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA.
CONTAINING 3.99 ACRES, MORE OR LESS.
SURVEYORS NOTES AND REPORT:
1. REPRODUCTIONS OF THIS MAP ARE NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A
FLORIDA LICENSED SURVEYOR AND MAPPER. THIS SURVEY CANNOT BE TRANSFERRED OR ASSIGNED WITHOUT THE
SPECIFIC WRITTEN PERMISSION OF ENGINEERING, DESIGN AND CONSTRUCTION, INC. IT IS A VIOLATION OF CHAPTER
5J-17, FLORIDA ADMINISTRATIVE CODE, TO ALTER THIS SURVEY WITHOUT THE EXPRESS PRIOR WRITTEN CONSENT
OF THE SURVEYOR. ADDITIONS AND/OR DELETIONS MADE TO THE FACE OF THIS SURVEY WILL MAKE THIS SURVEY
INVALID.
2. THE LAST DATE OF FIELD WORK WAS AUGUST 17, 2021.
3. CURRENT DESCRIPTION(S) SHOWN HEREON PROVIDED BY: THE CLIENT. A TITLE SEARCH FOR THIS PROPERTY HAS
NOT BEEN ABSTRACTED TO SHOW MATTERS OF RECORD SUCH AS EASEMENTS OR OTHER ENCUMBRANCES OR
RESTRICTIONS.
4. THE EXPECTED USE OF THE LAND, AS CLASSIFIED IN CHAPTER 5J-17.050-053, FLORIDA ADMINISTRATIVE CODE,
IS "COMMERCIAL/HIGH RISK." THE MINIMUM RELATIVE DISTANCE ACCURACY FOR THIS TYPE OF BOUNDARY SURVEY
IS 1 FOOT IN 10,000 FEET. THIS SURVEY EXCEEDS THE REQUIRED DISTANCE ACCURACY.
5. SUB -SURFACE IMPROVEMENTS INCLUDING UNDERGROUND UTILITIES, UTILITY SERVICES, WERE NOT LOCATED AS
PART OF THIS SURVEY.
6. REVISIONS SHOWN HEREON DO NOT REPRESENT A "FIELD SURVEY UPDATE" UNLESS OTHERWISE NOTED.
7. BEARINGS SHOWN HERON ARE BASED UPON GRID BEARINGS AND REFERENCE TO THE LINE LABELED HERON AS
(BEARING BASIS) AND ALL OTHER BEARINGS ARE RELATIVE THERETO. DISTANCES ARE IN U.S. SURVEY FEET AND
DECIMAL PARTS THEREOF.
8. ELEVATIONS SHOWN HEREON ARE RELATIVE TO THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88)
REFERENCING ST LUCIE COUNTY BENCHMARK "AF7708 (STL 4)" AT AN ELEVATION OF 18.00'
9. IN SOME INSTANCES, GRAPHIC REPRESENTATIONS AND SYMBOLS SHOWN HAVE BEEN EXAGGERATED TO MORE
CLEARLY ILLUSTRATE THE RELATIONSHIP BETWEEN PHYSICAL IMPROVEMENTS AND/OR LOT LINES. THE DIMENSIONS
SHOWN SHALL CONTROL THE LOCATION, OF THE IMPROVEMENTS, OVER THE SCALED POSITIONS.
10. THE OWNERSHIP OF PERIMETER FENCES, WALLS, HEDGES AND LANDSCAPING, IF ANY, SHOWN HEREON ARE NOT
KNOWN AND ARE NOT LISTED AS ENCROACHMENTS. THEIR RELATIVE LOCATION IS SHOWN IN RELATION TO THE
BOUNDARY LINES SHOWN.
11. THE SURVEY MAP SHOWN HEREON DOES NOT NECESSARILY CONTAIN ALL OF THE INFORMATION OBTAINED OR
DEVELOPED BY THE UNDERSIGNED SURVEYOR IN HIS FIELD WORK, OFFICE WORK OR RESEARCH.
12. THE PROPERTY WHICH IS THE SUBJECT OF THIS SURVEY APPEARS TO BE SITUATE IN AN AREA OF MINIMAL
FLOOD HAZARD AT THIS TIME PURSUANT TO F.E.M.A. FIRM NUMBER 12111 CO169J, HAVING AN EFFECTIVE DATE OF
FEBRUARY 16, 2012. FOR APPROXIMATE DELINEATION OF THE FLOOD ZONE LIMITS, REFER TO AFOREMENTIONED
FIRM PANELS.
13. BOUNDARY INFORMATION SHOWN HEREON COURTESY OF INDIAN RIVER SURVEYING, INC. DATED JANUARY 29, 2021
JOB NUMBER 20-003.
Digitally signed by Michael T.
Michael T. OwenOwen
Date: 2021.08.27 16:09:43-04'00'
MICHAEL T. OWEN PROFESSIONAL SURVEYOR AND MAPPER SIGNATURE DATE:
FLORIDA REGISTRATION #5556
ENGINEERS Q SURVEYORS
ENVIRONMENTAL
10250 VILLAGE PARKWAY
UNIT 201
PORT ST. LUCIE, FL 34987
772-462-2455
� www.edc-inc.com
F.B.P.E. CERTIFICATE OF AUTHORIZATION 9935
L.B. CERTIFICATE OF AUTHORIZATION 8098
>
miHl
Oz
Ow
04
W
1
�■■■■■■■■■■■■■J
V!
W
Lij
>
Z
W
a
Lu M
F-
UW=
J
G
W
�
LL
m
ry
LL
J
O
O�Z
LL
p
>
M
Q
Z
M
U
O
maw
0
=
U
O
LL
W
��:
in
Z
O
F-
LL
cfl
0
U
W
Uzi
10250 VILLAGE PARKWAY
UNIT 201
PORT ST. LUCIE, FL 34987
a 772-462-2455