Loading...
HomeMy WebLinkAboutTYPICAL SCREEN ENCLOSUREDo Y Kim Date: 2021 07.06 20:27 06im -04'00' ®® YF-=®P4 &CIM, R-a- Cam►_ # 26837 ®C)O lslm 8. P.®. E30OX 110039 -r^P F-A, [r L- 33679 (813) 87S-99SS 3' x 3' x 0.050' MIN. 6063-T6 ALLOY PLATE OR STRONGER (ONE SIDE) WITH (3) - #12 x %' SAS, EACH SIDE AS SHOWN (%' MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) 3' x 2' x 0.050' MIN. 6063-T6 ALLOY PLATE OR STRONGER (ONE SIDE) (3) - #12 x 44' S.M.S, EACH SIDE AS SHOWN (Y2' MIN. PLATE EDGE DISTANCE & C-C FASTENER SPACING) FOUNDATION (5) #120/4" S.M.S. 1x2 O.B. ATTACHED TO BEAM W/ (2)-#10X2" S.M.S. INTO SCREW BOSS (1)-1/4"xXt" S.S. THRU-BOLT W/ Ya" NUT AND WASHER ® EACH SIDE OF BEAM #12x2" S.M.S. ® 24" O.C. 1x2 O.B. TO SUPER GUTTER (4) #12x3/4" S.M.S. ROOF BEAM (FLAT OR SLOPED) , / CORNER POST EAVE RAIL RAG BEAM STITCHING SCREWS (SEE TABLE) @ 24. O.C. S�M� (I1 TOTAL) - #12 x %' SAS AS SHOWN (Y2' MIN. SPLICE PLATE (EACH SIDE OF BEAM) A D K I M PATIO SECTION PLATE EDGE DISTANCE & SPACE SCREWS q q 5052-H32 ALLOY OR EQUAL, 1/8' THICKNESS C-C FASTENER SPACING) EQUALLY (TYP.) & ASSOCIATES, L L C COLUMN G 6• x s' x o.oso• CONSULTING ° ° 6063-T6 ALLOY PLATE a (ONE SIDE) OR STRONGER A o w STRUCTURAL E N C3I N E E R S K-BRACE m 2x3xO.070 CHAIR RAIL cF� 6` m —� O •: J PO Box 10039 K-BRACE p Tampa, FL 33679 #14x3/4' SCREWS Tel: (813) 374-0321 K-BRACE CORNER POSTy� A 31tEs�l LINE LINE SCREWS BEAM "A' 'B'&'C° TOTAL PLATE WIDTH Rev./Date Description 1ii ct 4X117 oR Z P 2x4 3 2 24 12" 0 2015 ISSUED B QPa c l**> 1 VANE WS �0(N 2x5 3 3 32 14' 0 K-BRACE *1 #1�x 2x6 4 3 40 14" Q GIRT (CHAIR RAIL) B V��O�N `**** 1 2x7 5 4 56 16' 2x8 5 5 64 16' 2x9 5 6 72 18' ° 2x2x0.093 BRACE(TYP.), MANSARD BEAM 2x9(HW) 6 7 88 18' 0 ° UNLESS ° ° �1' x 2' OLE PLATE OTHERWISE CONNECTION DETAIL NOTED 2x10 7 7 96 18' ■ SEE ELEVATIONS FOR 'K' BRACE SIZE 9g" 0 CONCRETE ANCHOR (2 PLACES) IN LIEU OF TYP. Ya' 0 CONCRETE SCREWS FOR CORNER COLUMN (1)-2x2A" ANGLE, EACH SIDE--"- (2 FOR 2x8 SMB OR LARGER.) (4) #12x3/4" S.M.S. EACH LEG. 5' or 7' SUPER GUTTER MIN. 0.090' THICK LATERAL "K" - BRACING CONNECTION DETAILS Ix5xYs' ANGLE 6' LONG (TYP. @ EACH BEAM) (2) Y4'Ox3' LG. @ EACH ANGLE NOTE1 PRIMARY SCREEN ENCLOSURE BEAMS SHALL BE ATTACHED TO HOST STRUCTURE CONSISTING OF CONVENTIONAL TRUSS/RAFTER FRAMING WITH MAX. / FACIA TO BE 2x6 (MIN.) S.P.F. OVERHANG NO TO EXCEED 30' UNLESS ❑THERWISE OR WESTER RED CEDAR NOTED ON PLAN DWG. \> STRUCTURAL GRADE 2 MIN. (1) Ya'@x2' LG. LAG SCREW @ 24' O.C. ENTIRE LENGTH OF GUTTER ROOF BEAM TO SUPER GUTTER CONNECTION DETAIL (3) #12xXZ" S.M.S., EACH LEG AND MIN. (4) #10x3" LONG S.M.S. INTO (6) #12A" S.M.S. CHANNEL TO BEAM SCREW BOSSES (TYP. ALTERNATIVE) (9) SCREW TOTAL BEAM STITCHING ® 24" O.C. � (TYP. TOP AND BOTTOM OF SMB J 2x3xO.070 SEE TABLE FOR SIZES) PURLIN Q 1x1A" BY 2" LONG ANGLE, EACH SIDE (TYP.) \ 2x3xO.070 GIRT/CHAIR RAIL \\1� (SEE PLAN) BRAKE -FORMED RECIEVING CHANNEL (MIN. 0.062" MATERIAL THICKNESS) 1"x21/8"x 1"x3"LG. (TYP. ALTERNATIVE) MIN. (4) #10x2" LONG (4) #14x)4" S.M.S., S.M.S. INTO SCREW BOSSES 2 SCREWS (TYP. ALTERNATIVE) EACH LEG (TYP.) S.M.B. POST HOLLOW POST PURLIN TO ROOF BEAM CONNECTION DETAIL CHAIR RAIL / GIRT TO POST SECURE FASCIA T❑ EACH RAFTER TAIL (2) #10x4" S.M.S. THRU. 2x3 W/ (1)4Ox4' LONG PAN HEAD LAG SCREWS EAVE RAIL INTO PURLIN SCREW BEFORE ATTACHING SUPER GUTTER BOSSES USE #100Y2" S.M.S. ® 24" O.C. TO CONNECT TO 1x2 O.B. TO 2x3. n 11) Y4'@x2' LG, LAG SCREWS C �f (TYP. @ EACH BEAM) 1x2 O.B. FASTENED TO COLUMN/POST f� l 11) #12x2' @ 1o.c. BETWEEN BEAMS W/(2) #10x%" S.M.S. INTO SCREW BOSSES ,MAX)(M (EACH END, TYP.) ANGLEICK CONTINUOUS SECURE FASCIA TO EACH RAFTER TAIL W/ (1) Yi Ox4' LONG PAN HEAD LAG SCREWS BEFORE ATTACHING SUPER GUTTER #10x3/4" S.M.S. Y4' CONTINUOUS BEAD OF CONSTRUCTION ® 2' O.C. ADHESIVE CONNECTION DETAIL 2x3xO.045 EAVERAIL ATTACHED TO BEAMS WITH (3)-#10x2" S.M.S. 2x PURLIN INTO SCREW BOSS. (MAY BE SLOPED OR FLAT) 2x5x.125 ANGLE-2" WIDE WITH INTO#UPRIIGHT.TO BEAM & (2)-#14x1 = i USE #10x1Y2" S.M.S. ® 24" O.C. — TO CONNECT TO 1x2 O.B. TO 20. PURLIN FASTENED TO COLUMN/POST (9) #12x%" S.M.S. EACH SIDE. WITH (4) #12x1" S.M.S. (EACH LEG) OF BEAM (TYP.) OR USING Ya" THICK FLAT BAR BENT (6) #12>�%" S.M.S. EACH SIDE TO FIT (6063-T6 ALLOY) OF BEAM FOR 2x5 COLUMN TO \ 2x5 BEAM COLUMN/POST cni I iuti /p, SIDEWALL POST / COLUMN TO PURLIN CONNECTION DETAIL W � C — W 0 10 4" BY 3" LONG U ANGLE, EACH SIDE (TYP.) C O (3) #12x)¢" S.M.S., EACH U LEG (6) TOTAL (TYP.) U z W W L z Lu N W C z 0' g O U a U) Q z U W co 0_ J W } U 0 � DRAWN BY: DYK CHECKED BY: DYK S.M.B. BEAM SCALE: AS SHOWN MAY BE SLOPED OR FLAT (SEE PLAN FOR SIZE) DATE: 8/11/06 Y¢' MIN., 3 Y2' MAX. C-C SPACING OF FASTENERS (TYP.) Y2' MIN. BEAM EDGE DISTANCE (TYP.) MAIN POST / COLUMN TO ROOF BEAM DOYEON KIM, P.E. I FLA. REG. NUMBER 49497 DO KIM & ASSOCIATES, LLC I CA# 26887 PO Box 10039 Tampa, FL 33679 Drawing No. - 060811 SHEET 1 OF 3 PURLIN SUPPORT COLUMN/POST Yg" ANGLE, EACH SIDE (TYP.) 2x2x1/B" x 2" LG. ANGLE S.M.S. WITH MIN. 3'g" %"0 CONCRETE ANCHOR W/ (4) #12x3/4" S.M.S EDGE DISTANCE W/2%" EMBEDMENT INTO (EACH SIDE) STRUCTURAL CONCRETE (TYP., %"0 CONCRETE ANCHOR E NOTE 10) 1"x2" O.B. SOLE PLATE C W/2%" EMBEDMENT INTO 2% PURLIN STRUCTURAL CONCRETE (EACH SIDE) 3" MIN. (TYP.) BEAM MAY z?w Y4"0x2Y4" CONCRETE BE FLAT f U U SCREW ANCHOR 0 24" O.C. OR SLOPED ago N U AND 9" FROM POST (TYP.) SIDEWALL COLUMN TO CONCRETE CONNECTION DETAIL SEE PLAN FOR SIZE EDGE OF CONCRETE 1x2 O.B. FASTENED TO CORNE SECTION WITH #14xl)¢" S.M.S.x 24" O.C. 2x24" ANGLE 2" LONG (EACH W/(2) #14x%" S.M.S. TO POS & 3/8"0 H.D. GALV. EXP. BOIL W/ 2 1/2" MIN. EMBEDMENT If CORNER POST/COLUMN TO CONCRETE CONNECTION DETAIL )8- ANGLE, EACH SIDE (TYP.) S.M.S. WITH MIN. 3/g" EDGE DISTANCE %"0 CONCRETE ANCHOR W/2%" EMBEDMENT INTO STRUCTURAL CONCRETE (TYP., SEE NOTE 10) �1"x2" O.B. SOLE PLATE . .� • 44 '�i �.1 ' cl�� 3" MIN. (TYP.) W Y4"OxZY4" CONCRETE f SCREW ANCHOR 0 24" O.C. a"" wo F U ti AND 9" FROM POST (TYP.) COLUMN/POST ix2 O.B. SOLE PLATE I 1' (TYP.) EDGE OF CONCRETE PLAN VIEW MAIN COLUMN TO CONCRETE CONNECTION DETAIL PLAN VIEW COLUMN/POST >,�� O.B. SOLE PLATE 1' (TYP.) H r < N PLAN - TYPICAL DIAGONAL ROOF BRACE CONNECTION 2x24" ANGLE CLIP, CUT AT A 45- (+/-) ANGLE AND ATTACHED TO THE SCREEN ROOF BEAM WITH ONE (1) Y4"0 THRU- BOLT, WITH FENDER WASHER. ATTACHED TO BEAM OR EAVE RAIL. / DIAGONAL BRACING SHALL NOT BE ATTACHED TO ROOF PURLINS. 2x2xO.093 BRACE (SEE PLAN) 1+1 1x3 O.B. FASTENED TO CORNER SECTION WITH #10x2" S.M.S. W/ %" DIA. WASHER 0 18" O.C. 2x5x.%' ANGLE (2' LONG) W/ (2)-#14 TEKS INT❑ TOP OF 2x3 EAVE RAIL AND (2)- #14 TEKS INTO THE FRONT OF THE CORNER POST L1x2 O.B. TOP FRAME CORNER POST -1x O.B. SIDE WALL CORNER UPRIGHT ELEVATION VIEW CORNER POST/COLUMN UPRIGHT DETAIL COLUMN 'd d •, MAX. THICK BRICK PAVERS GRA APPROXIMATE 4 SET SET IN MORTAR. ON TOP OF FOOTER * _II C d O.B. SOLE PLATE -I I I d d ja IIIIII 'a' C4 ���Ft IIIIII 4. A - IIIIII a a• 12" MIN.* PSI MIN. CONCRETE STRENGTH COMPACTED OR UNDISTURBED SOIL/SAND •(1)—#5 REBAR, CONTINUOUS 3" MIN. CONC. COVER, 36" MIN LAP SPLICE MIN. CONTINUOUS PERIMETER FOOTING (4) #12x3'4" 2"x PURLIN BEAM MAY BE FLAT OR SLOPED (2) #10x7i2 nP. EACH (2) #1 Ox3K2 nP. EACH PLAN - TYPICAL ROOF BRACE TO BEAM CONNECTION 1 RNATE (1) ANGLE E A- ANGLE (BRACE) W/ 112x-Y4" S.M.S. 0 EACH ER INTERSECTION 3" ANGLE 2" LONG ON RSIDEW/(4) #12x3'4" S.M.S. LEG (BEAM & BRACE) 3RACE PLAN) ALTERNATE (2) 2x3 BRACE DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 Z 7127 ISSUED 2015 0 0 0 U) J Q C — w U u O J � Z U w U) a) w a) w C Z a O U) ~ � � J Q Z d U W_ U) J W d � DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: 8/11 /06 DOYEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM & ASSOCIATES, LLC I CA# 26887 PO Box 10039 Tampa, FL 33679 FOUNDATION/SLAB DETAIL Drawing No. - 060811 SHEET 2 OF 3 #10x4' S.M.S. W/ lY4'0 FENDER WASHER AND NEOPRENE GASKET @ 12' D.C. 1x2 O.B. — (OPTIONAL) (2) Yq Ox2Y2' LG. LAG SCREW EACH SIDE OF BEAM (TYP.) (4) #143/4" S.M.S. (TYP.) ROOF BEAM (FLAT OR SLOPED) 2x24" ANGLE, EACH SIDE (TYP.) (8) #14x3/4" S.M.S., (4) SCREWS EACH LEG (TYP.) FACIA TO BE 2x6 (MIN.) S.P.F. (CEDAR IS NOT ACCEPTABLE), STRUCTURAL GRADE 2 MIN. SECURE FASCIA TO EACH RAFTER TAIL W/ (1) Y4'Ox4' LONG PAN HEAD LAG SCREWS BEFORE ATTACHING SUPER GUTTER CARRIER BEAM TO FASCIA CONNECTION DETAIL 13) #14x%' S.M.S. (TYP. EACH STRAP AND EACH SIDE) (1)-1/4"YX2" S.S. THRU-BOLT W/ Y4" NUT AND WASHER 0 EACH SIDE OF BEAM 1x2 O.B. #12x2" S.M.S. 0 24" D.C. 1x2 O.B. TO SUPER GUTTER (4) #140/4" S.M.S. (TYP.) 00 S.M.B. BEAM O ®i 00 2x2A" ANGLE, EACH SIDE (TYP.) (8) #14x3/4" S.M.S., 4 SCREWS EACH LEG (TYP.) SUPER GUTTER 1x14" ANGLE 3" LONG (EACH SIDE) W/ (3) #14x3/4" S.M.S. EACH 2x3 PURLIN ATTACHED TO BEAMS WITH (2) #10x1Yz" S.I INTO SCREW BOSSES(TYP.) USE #10x1Y2" S.M.S. 0 24" , TO CONNECT TO 1x2 O.B. TC 2x%" S.M.S. EACH SIDE 2X COLUMN (SEE PLAN Ix5xY9' ANGLE 4' LONG (TYP. @ EACH BEAM) / SECURE FASCIA TO EACH RAFTER TAIL FLASHING, SEAL AS REQ'DAl W/ (1) Y4'0 x 4' LONG PAN HEAD LAG SCREWS BEFORE ATTACHING RECEIVING CHANNELJJ #14xY2' SMS W/ INTEGRAL 3/q'0 EXTRUDED OR BRAKE —FORMED ROOF HE R WASHER AND NEOPRENE GASKET OR RECEIVING CHANNEL C0.044' MIN. THIIICCKNESS) ( 12 D.C. TOP & BOTTOM. WITH MIN. IYz' BEARING LEG. (COMPOSITE RDDF) SLOPE (1) Y4'0 x 2' LAG SCREW @ 24' O.C. ENTIRE LENGTH OF RECEIVING CHANNEL 00000SDFFIT 0000///0 O COMPOSITE PANEL (SEE PLAN FOR SIZE) COMPOSITE ROOF TO HOST STRUCTURE CONNECTION DETAIL #14x4' S.M.S. W/ 1Y4'0 FENDER WASHER AND NEOPRENE GASKET @ 12' D.C. l SLOPE iotxo.) rO O O O O O 00000000000000c O0-cOo0�0-0-0-0� SCREEN ROOF TO PANEL OR COMPOSITE ROOF CONNECTION DETAIL 3' (1 LB EPS) COMPOSITE PANEL S.M.B. BEAM (SEE PLAN FOR SIZE) Yz' MIN., 3 Ya' MAX. C—C SPACING OF FASTENERS (TYP.) Ya' MIN. BEAM EDGE DISTANCE (TYP.) 3' COMPOSITE ROOF PANELS O O O O O O O O U`ID000 0000000000000 0 0 0 0 0 0 0 Y2' PANEL WIDTH MAX. PATIO SIDE WALL HEADER (SEE PLAN FOR SIZE) (4) #10x2" S.M.S. THRU. UPRI INTO EAVE RAIL/HEADER SCREW BOSSES e COMPOSITE ROOF TO HOLLOW SIDE WALL HEADER CONNECTION DETAIL General Notes and Specifications: 1. Contractor shall field verify all dimensions before construction and shall notify engineer of discrepancies for immediate consideration. 2. Concrete shall be minimum 28 day compressive strength of f'c=3500 psi, and be in accordance with the requirements of ACI 318. Reinforcing steel shall have a min. yield strength of 40,000 psi (grade 40) and be provided with cover in accordance with ACI 318. 3. All dimensions are provided by contractor, DO Kim & Associates, LLC have made interpretations where necessary. 4. The following structures are designed to be attached to block and wood frame structures of adequate structural capacity. The contractor shall verify that the host structure is in good condition and of sufficient strength to hold the proposed addition. If there is a question about the host structure, the owner (at his own expense) shall hire an architect or engineer to verify host structure capacity. 5. Screen density shall be a maximum of 18 x 14 x 0.013" mesh. Aluminum shall be 7005-T53 Alloy, 6005-T5 Alloy; for secondary components 6063-T6, Alloy based on industry standard shapes, thicknesses, and tolerances unless otherwise noted. 6. Unless otherwise noted, SMB shall be stitched with #10x3/4" SMS at 24"o.c., top and bottom. 7. Connections using screw bosses shall have minimum (4)410x2" per connection unless shown otherwise. 8. Unless otherwise shown, screws shall have minimum edge distance and center -to -center distances as shown in this table. C-1022 Low Carbon Steel SMS & Self -Drilling (TEK) Screws (Industry Standard Screws) Screw Nominal Screw Diameter (in) Minimum Edge Distance Minimum Center to Center Distance # 10 0.188 5/16 " 1/2" #12 0.219 3/8" 9/16" #14 (1/4") 0.250 1/2" s/8', 9. Structure has been designed to meet the 711 Edition FBC (2020 FBC). Project is sited where the ultimate design wind speed, Vult, is 150 mph (3-sec gust) for risk category I buildings and other structures. Exposure C. Design pressures are from Table 2002.4, 2020 FBC reduced by 0.88 for screen mesh factor, 0.6 for allowable stress design (ASO). 10. Concrete anchors may be "Large Diameter Tapcons" (LTDs), Tapcon concrete screws, Simpson Strong -Tie Anchors or Titian Screws or approved equal. 11. Aluminum roof pans shall be of aluminum alloy 3105-H14 or 3105-H28. Composite panel skins shall be of aluminum alloy 3105-H15 or 3105-H25. DO KIM & ASSOCIATES, LLC CONSULTING STRUCTURAL ENGINEERS PO Box 10039 Tampa, FL 33679 Tel: (813) 374-0321 Rev Datel Description "6 ISSUED 2019 IL 0 0 0 U) J_ Q W U 0 W CY O U cq O U N z U W � Z O W N W C Z 0Y p U CL U) • J Z (� U W_ J W } DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE: 8/11/06 DO YEON KIM, P.E. FLA. REG. NUMBER 49497 DO KIM & ASSOCIATES, LLC CA# 26887 PO Box 10039 Tampa, FL 33679 2X CARRIER BEAM TO 2X UPRIGHT CONNECTION DETAIL 12. Screen enclosure structure shall meet Section 454.2.17 Residential Swimming Barrier Requirements and the screen enclosure per 454.2.17.1.11. if enclosing a pool. Drawing No. - 060811 SHEET 3 OF 3