Loading...
HomeMy WebLinkAbouttbd carlton rd fa HEALTH DEPARTMENT APPROVALAPPLICATION # : AP 1606194 STATE OF FLORIDA PERMIT #:56-SF-2211896 DEPARTMENT OF HEALTH DOCUMENT #:F11680860 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:12/09/2020 FEE PAID:660.00 RECEIPT #:56-PID-4825916 APPLICANT: Kylie Fasnacht AGENT: PROPERTY ADDRESS: TBD Carlton Rd Port Saint Lucie, FL 34987 LOT: SUBDIVISION: BLOCK: ID# : 3234-231-0001-000-5 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1090.00 [2] [ ] [27] SURFACE WATER 75 FT [ ] [02] TANK MATERIAL Polypropylene [ ] [28] DITCHES FT [ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS 80 FT [ 1 [041 MULTI -CHAMBERED ( Y N ] [ ] [301 PUBLIC WELLS FT [ ] [05] OUTLET FILTER PolylokPL-68 [ ] [31] IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-143-11DC4 2. [ ] [32] POTABLE WATER 17 FT [ ] [071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 6 FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES 55 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 384.88 [2] SQFT [ ] [361 DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 5.00 2. [ ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 08/13/2021 [ ] [141 DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ AHOVE / BELOW ]BM 11.00 [ ] [40] UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [421 ALARMS [ ] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] (201 AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN [ ] [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] (221 FILL AMOUNT [ ] [47] CONTRACTOR Jason Harris (All About Septi [ ] [23] FILL TEXTURE [ 1 [481 OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [49] TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION L APPROVED St. Lucie CHD DISAPPROVED ] ' Enviro ental Speciali Brian J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]: St. Lucie CHD Environmental Speciali III Brian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1606194 EID2211896 DATE: 03/29/2021 DATE : nR/vi/2n21 Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1606194 PERMIT #:56-SF-2211896 DOCUMENT #: F11680860 DATE PAID-12/09/2020 FEE PAID:660.00 RECEIPT #:56-PID-4825916 The system is sized for 2 bedrooms with a maximum occupancy of 4 persons (2 per bedroom), for a total estimated flow of 300 3pd• Vew ST, filter, and 4x7+1x6 long TRENCH DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final nspection for well inspection/setback, potable water line setback, mound system, and final site grading. =inal system approved. Home owner, contractor and Building Department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1606194 EID2211896