HomeMy WebLinkAboutEnvelope Compliance CertificateCOMcheck Software Version 4.1.1.0
Envelope Compliance Certificate
Project Information
Energy Code:
Project Title:
Location:
Climate Zone:
Project Type:
Vertical Glazing / Wall Area:
Construction Site:
N. Highway AIA
1/4 Mile South of the Breakers
St. Lucie County, FL, FL 34949
2017 Florida Building Code, Energy Conservation
18070 Cristelle Cay ailftsh
Vero Beach, Florida
2a
New Construction
26%
Owner/Agent:
David Gilman
OD I LLC
6105 Transit Road #140
Amhirst, NY 14051
card! nalsouthern@aol.com
Designer/Contractor:
Frank Snedaker jr
3015 N. Ocean Blvd
Suite C-123
Ft. Lauderdale, FL 33308
954-561-4455
Additional Efficiency Package(s)
Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations.
Building Area Floor Area
1-Parking Garage: Residential
5809
2-Multifamily: Nonresidential
1720
3-Multifamily: Nonresidential
1678
4-Multifamily: Nonresidential
1720
5-Multifamily: Nonresidential
1720
6-Multifamily: Nonresidential
1678
7-Multifamily: Nonresidential
1720
8-Multifamily: Nonresidential
1720
Multifamily: Nonresidential
1678
10-Multifamily : Nonresidential
1720
11-Parking Garage : Residential
6938
12-Multifamily : Nonresidential
1446
13-Multifamily : Nonresidential
1448
14-Multifamily : Nonresidential
1448
15-Multifamily : Nonresidential
1446
16-Multifamily : Nonresidential
1446
17-Multifamily : Nonresidential
1448
18-Multifamily : Nonresidential
1448
19-Multifamily : Nonresidential
1446
20-Multifamily : Nonresidential
1446
21-Multifamily : Nonresidential
1448
22-Multifamily : Nonresidential
1448
23-Multifamily : Nonresidential
1446
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users�ohnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish.cck Page 1 of 37
' v'tii T li i P, '
Envelope Assemblies
Assembly
Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factor(a)
Perimeter
Roof 1: Insulation Entirely Above Deck: High Albedo Roof Required, 3-
1720 - 19.0 0.051 0.039
Year -Aged Solar Reflectance = 0.55, Thermal Emittance = 0.75 (c),
[Bldg. Use 8 - Multifamily]
Roof 1 copy 1: Insulation Entirely Above Deck: High Albedo Roof
1678 -- 19.0 0.051 0.039
Required, 3-Year-Aged Solar Reflectance = 0.55, Thermal Emittance =
0.75 (c), [Bldg. Use 9 - Multifamily]
Roof 1 copy 2: Insulation Entirely Above Deck: High Albedo Roof
1720 - 19.0 0.051 0.039
Required, 3-Year-Aged Solar Reflectance = 0.55, Thermal Emittance =
0.75 (c), [Bldg. Use 10 - Multifamily]
Roof 1 copy 3: Insulation Entirely Above Deck: High Albedo Roof
1446 -- 19.0 0.051 0.039
Required, 3-Year-Aged Solar Reflectance = 0.55, Thermal Emittance =
0.75 (c), [Bldg. Use 20 - Multifamily]
Roof 1 copy 4: Insulation Entirely Above Deck: High Albedo Roof
1448 -- 19.0 0.051 0.039
Required, 3-Year-Aged Solar Reflectance = 0.55, Thermal Emittance =
0.75 (c), [Bldg. Use 21 - Multifamily]
Roof 1 copy 5: Insulation Entirely Above Deck: High Albedo Roof
1446 - 19.0 0.051 0.039
Required, 3-Year-Aged Solar Reflectance = 0.55, Thermal Emittance =
0.75 (c), [Bldg. Use 22 - Multifamily]
Roof 1 copy 6: Insulation Entirely Above Deck: High Albedo Roof
1448 - 19.0 0.051 0.039
Required, 3-Year-Aged Solar Reflectance = 0.55, Thermal Emittance =
0.75 (c), [Bldg. Use 23 - Multifamily]
NORTH
Exterior Wall 1: Concrete Block:8", Partially Grouted, Cells Empty,
468 -- 8.0 0.095 0.123
Medium Density, Furring: None, [Bldg. Use 1 - Parking Garage]
Exterior Wall 1 copy 4: Concrete Block:8", Partially Grouted. Cells
432 - 8.0 0.095 0.123
Empty, Medium Density, Furring: None, [Bldg. Use 11 - Parking
Garage]
Exterior Wall 1 copy 5: Concrete Block:8", Partially Grouted, Cells
387 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 2 - Multifamily]
Window 1: Metal Frame:Operable, Perf. Specs.: Product ID Pending,
30 - - 0.500 0.650
SHGC 0.25, [Bldg. Use 2 - Multifamily] (b)
Window 1 copy 1: Metal Frame:Operable, Perf. Specs.: Product ID
12 --- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 2 - Multifamily] (b)
Window 1 copy 3: Metal Frame:Operable, Perf. Specs.: Product ID
56 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 2 - Multifamily] (b)
Window 1 copy 2: Metal Frame:Operable, Pert. Specs.: Product ID
9 -- - 0.500 0,650
Pending, SHGC 0.25, [Bldg. Use 2 - Multifamily] (b)
Exterior Wall 1 copy 6: Concrete Block:8", Partially Grouted, Cells
387 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 5 - Multifamily]
Window 1 copy 1: Metal Frame:Operable, Perf. Specs.: Product ID
30 -- --- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 5 - Multifamily] (b)
Window 1 copy 2: Metal Frame:Operable, Perf. Specs.: Product ID
12 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 5 - Multifamily] (b)
Window 1 copy 4: Metal Frame:Operable, Pert. Specs.: Product ID
56 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 5 - Multifamily] (b)
Window 1 copy 3: Metal Frame:Operable, Perf. Specs.: Product ID
9 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 5 - Multifamily] (b)
Exterior Wall 1 copy 8: Concrete Block:B", Partially Grouted, Cells
387 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 8 - Multifamily]
Window 1 copy 3: Metal Frame:Operable, Perf. Specs.: Product ID
30 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 8 - Multifamily] (b)
Window 1 copy 4: Metal Frame:Operable, Pert. Specs.: Product ID
12 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 8 - Multifamily] (b)
Window 1 copy 6: Metal Frame:Operable, Perf. Specs.: Product ID
56 - - 0.500 0.650
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070-Cristelle-Cay-Sailfish.cck Page 2 of 37
Assembly Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factorial
Perimeter
Pending, SHGC 0.25, [Bldg. Use 8 - Multifamily] (b)
Window 1 copy 5: Metal Frame:Operable, Perf. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 8 - Multifamily] (b)
Exterior Wall 1 copy 9: Concrete Block:8", Partially Grouted, Cells
Empty, Medium Density, Furring: Wood, [Bldg. Use 12 - Multifamily]
Window 1 copy 4: Metal Frame:Operable, Perf. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 12 - Multifamily] (b)
Window 1 copy 5: Metal Frame:Operable, Pert. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 12 - Multifamily] (b)
Window 1 copy 7: Metal Frame:Operable, Pert. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 12 - Multifamily] (b)
Window 1 copy 6: Metal Frame:Operable, Perf. Specs.: Product ID
Pending, SHGC 0:25, [Bldg. Use 12 - Multifamily] (b)
Exterior Wall 1 copy 10: Concrete Block:8", Partially Grouted, Cells
Empty, Medium Density, Furring: Wood, [Bldg. Use 16 - Multifamily]
Window 1 copy 5: Metal Frame:Operable, Perf. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 16 - Multifamily] (b)
Window 1 copy 6: Metal Frame:Operable, Perf. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 16 - Multifamily] (b)
Window 1 copy 8: Metal Frame:Operable, Pert. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 16 - Multifamily] (b)
Window 1 copy 7: Metal Frame:Operable, Pert. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 16 - Multifamily] (b)
Exterior Wall 1 copy 11: Concrete Block:8", Partially Grouted, Cells
Empty, Medium Density, Furring: Wood, [Bldg. Use 20 - Multifamily]
Window 1 copy 6: Metal Frame:Operable, Pert. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 20 - Multifamily] (b)
Window 1 copy 7: Metal Frame:Operable, Pert. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 20 - Multifamily] (b)
Window 1 copy 9: Metal Frame:Operable, Pert. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 20 - Multifamily] (b)
Window 1 copy 8: Metal Frame:Operable, Perf. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 20 - Multifamily] (b)
EAST
Exterior Wall 1 copy 1: Concrete Block:8", Partially Grouted, Cells
Empty, Medium Density, Furring: None, [Bldg. Use 1 - Parking Garage]
Exterior Wall 1 copy 5: Concrete Block:8", Partially Grouted, Cells
Empty, Medium Density, Furring: None, [Bldg. Use 11 - Parking
Garage]
Exterior Wall 1 copy 6: Concrete Block:8", Partially Grouted, Cells
Empty, Medium Density, Furring: Wood, [Bldg. Use 2 - Multifamily]
Window 1 copy 4: Metal Frame:Operable, Pert. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 2 - Multifamily] (b)
Window 1 copy 5: Metal Frame:Operable, Perf. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 2 - Multifamily] (b)
Exterior Wall 1 copy 7: Concrete Block:8", Partially Grouted, Cells
Empty, Medium Density, Furring: Wood, [Bldg. Use 3 - Multifamily]
Window 1 copy 5: Metal Frame:Operable, Perf. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 3 - Multifamily] (b)
Window 1 copy 6: Metal Frame:Operable, Pert. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 3 - Multifamily] (b)
Exterior Wall 1 copy 7: Concrete Block:8", Partially Grouted, Cells
Empty, Medium Density, Furring: Wood, [Bldg. Use 4 - Multifamily]
Window 1 copy 5: Metal Frame:Operable, Pert. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 4 - Multifamily] (b)
Window 1 copy 6: Metal Frame:Operable, Perf. Specs.: Product ID
Pending, SHGC 0.25, [Bldg. Use 4 - Multifamily] (b)
9
-
--
0.500
0.650
387
0.0
8.0
0.086
0.151
30
-
-
0.500
0.650
12
-
-
0.500
0,650
56
-
--
0.500
0.650
9
-
--
0.500
0.650
387
0.0
8.0
0.086
0.151
30
-
--
0.500
0.650
12
-
--
0.500
0.650
56
-
--
0.500
0.650
9
-
-
0.500
0.650
387
0.0
8.0
0.086
0.151
30
-
--
0.500
0.650
12
-
--
0.500
0.650
56
-
-
0.500
0.650
9
-
--
0.500
0.650
1044
-
8.0
0.095
0.123
1350
-
8.0
0.095
0.123
342
0.0
8.0
0.086
0.151
120
-
-
0.500
0.650
64
--
-
0.500
0.650
342
0.0
8.0
0.086
0.151
120
-
--
0.500
0.650
64
--
-
0.500
0.650
342
0.0
8.0
0.086
0.151
120
-
--
0.500
0.650
64
--
--
0.500
0.650
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users�ohnferriter\Documents\COMcheck\18070 Cristelle Cay-Sailfish.cck Page 3 of 37
Assembly
Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factor(.)
Perimeter
Exterior Wall 1 copy 7: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 5 - Multifamily]
Window 1 copy 5: Metal Frame:Operable, Perf. Specs.: Product ID
120 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 5 - Multifamily] (b)
Window 1 copy 6: Metal Frame:Operable, Pert. Specs.: Product ID
64 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 5 - Multifamily] (b)
Exterior Wall 1 copy 8: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 6 - Multifamily]
Window 1 copy 6: Metal Frame:Operable, Perf. Specs.: Product ID
120 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 6 - Multifamily] (b)
Window 1 copy 7: Metal Frame:Operable, Perf. Specs.: Product ID
64 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 6 - Multifamily] (b)
Exterior Wall 1 copy 8: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 7 - Multifamily]
Window 1 copy 6: Metal Frame:Operable, Pert. Specs.: Product ID
120 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 7 - Multifamily] (b)
Window 1 copy 7: Metal Frame:Operable, Perf. Specs.: Product ID
64 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 7 - Multifamily] (b)
Exterior Wall 1 copy 9: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 8 - Multifamily]
Window 1 copy 7: Metal Frame:Operable, Pert. Specs.: Product ID
120 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 8 - Multifamily] (b)
Window 1 copy 8: Metal Frame:Operable, Pert. Specs.: Product ID
64 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 8 - Multifamily] (b)
Exterior Wall 1 copy 9: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 9 - Multifamily]
Window 1 copy 7: Metal Frame:Operable, Perf. Specs.: Product ID
120 -- -- 0.500 0.650
Pending, 31 IGC 0.25, [Dldg. Use 9 - Multifamily] (b)
Window 1 copy 8: Metal Frame:Operable, Pert. Specs.: Product ID
64 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 9 - Multifamily] (b)
Exterior Wall 1 copy 10: Concrete Block:8", Partially Grouted,,Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 10 - Multifamily]
Window 1 copy 8: Metal Frame:Operable, Perf. Specs.: Product ID
120 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 10 - Multifamily] (b)
Window 1 copy 9: Metal Frame:Operable, Perf. Specs.: Product ID
64 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 10 - Multifamily] (b)
Exterior Wall 1 copy 10: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 12 - Multifamily]
Window 1 copy 8: Metal Frame:Operable, Perf. Specs.: Product ID
120 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 12 - Multifamily] (b)
Window 1 copy 9: Metal Frame:Operable, Pert. Specs.: Product ID
64 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 12 - Multifamily] (b)
Exterior Wall 1 copy 10: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 13 - Multifamily]
Window 1 copy 8: Metal Frame:Operable, Perf. Specs.: Product ID
120 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 13 - Multifamily] (b)
Window 1 copy 9: Metal Frame:Operable, Perf. Specs.: Product ID
64 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 13 - Multifamily] (b)
Exterior Wall 1 copy 11: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 14 - Multifamily]
Window 1 copy 9: Metal Frame:Operable, Perf. Specs.: Product ID
120 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 14 - Multifamily] (b)
Window 1 copy 10: Metal Frame:Operable, Perf. Specs.: Product ID
64 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 14 - Multifamily] (b)
Exterior Wall 1 copy 11: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 15 - Multifamily]
Window 1 copy 9: Metal Frame:Operable, Pert. Specs.: Product ID
120 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 15 - Multifamily] (b)
Project Title: 18070 Cristelle Cay Sailfish
Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070_Cristelle-Cay-Sailfish,cck Page 4 of 37
a
Assembly
Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factor(.)
Perimeter
Window 1 copy 10: Metal Frame:Operable, Pert. Specs.: Product ID
64 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 15 - Multifamily] (b)
Exterior Wall 1 copy 11: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 16 - Multifamily]
Window 1 copy 9: Metal Frame:Operable, Pert. Specs.: Product ID
120 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 16 - Multifamily] (b)
Window 1 copy 10: Metal Frame:Operable, Pert. Specs.: Product ID
64 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 16 - Multifamily] (b)
Exterior Wall 1 copy 11: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 17 - Multifamily]
Window 1 copy 9: Metal Frame:Operable, Pert. Specs.: Product ID
120 --- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 17 - Multifamily] (b)
Window 1 copy 10: Metal Frame:Operable, Pert. Specs.: Product ID
64 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 17 - Multifamily] (b)
Exterior Wall 1 copy 12: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 18 - Multifamily]
Window 1 copy 10: Metal Frame:Operable, Pert. Specs.: Product ID
120 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 18 - Multifamily] (b)
Window 1 copy 11: Metal Frame:Operable, Perf. Specs.: Product ID
64 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 18 - Multifamily] (b)
Exterior Wall 1 copy 12: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 19 - Multifamily]
Window 1 copy 10: Metal Frame:Operable, Perf. Specs.: Product ID
120 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 19 - Multifamily] (b)
Window 1 copy 11: Metal Frame:Operable, Perf. Specs.: Product ID
64 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 19 - Multifamily] (b)
Exterior Wall 1 copy 12: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 20 - Multifamily]
Window 1 copy 10: Metal Frame:Operable, Perf. Specs.: Product ID
120 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 20 - Multifamily] (b)
Window 1 copy 11: Metal Frame:Operable, Perf. Specs.: Product ID
64 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 20 - Multifamily] (b)
Exterior Wall 1 copy 12: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 21 - Multifamily]
Window 1 copy 10: Metal Frame:Operable, Perf. Specs.: Product ID
120 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 21 - Multifamily] (b)
Window 1 copy 11: Metal Frame:Operable, Perf. Specs.: Product ID
64 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 21 - Multifamily] (b)
Exterior Wall 1 copy 13: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 22 - Multifamily]
Window 1 copy 11: Metal Frame:Operable, Pert. Specs.: Product ID
120 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 22 - Multifamily] (b)
Window 1 copy 12: Metal Frame:Operable, Perf. Specs.: Product ID
64 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 22 - Multifamily] (b)
Exterior Wall 1 copy 13: Concrete Block:8", Partially Grouted, Cells
342 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 23 - Multifamily]
Window 1 copy 11: Metal Frame:Operable, Perf. Specs.: Product ID
120 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 23 - Multifamily] (b)
Window 1 copy 12: Metal Frame:Operable, Perf. Specs.: Product ID
64 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 23 - Multifamily] (b)
SOUTH
Exterior Wall 1 copy 2: Concrete Block:8", Partially Grouted, Cells
468 - 8.0 0.095 0.123
Empty, Medium Density, Furring: None, [Bldg. Use 1 - Parking Garage]
Exterior Wall 1 copy 6: Concrete Block:8", Partially Grouted, Cells
432 - 8.0 0.095 0.123
Empty, Medium Density, Furring: None, [Bldg. Use 11 - Parking
Garage]
Exterior Well 1 copy 6: Concrete Block:8", Partially Grouted, Cells
387 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 4 - Multifamily]
Project Title: 18070 Cristelle Cay Sailfish
Report date: 12/10/18
Data filename: C:\Users\ ohnferriter\Documents\COMcheck\18070
Cristelle Cay-Sailfish.cck Page 5 of 37
Assembly
Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factor(a)
Perimeter
Window 1 copy 1: Metal Frame:Operable, Perf. Specs.: Product ID
30 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 4 - Multifamily] (b)
Window 1 copy 2: Metal Frame:Operable, Perf. Specs.: Product ID
12 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 4 - Multifamily] (b)
Window 1 copy 3: Metal Frame:Operable, Perf. Specs.: Product ID
9 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 4 - Multifamily] (b)
Window 1 copy 4: Metal Frame:Operable, Perf. Specs.: Product ID
56 -- - 0.600 0.650
Pending, SHGC 0.25, [Bldg. Use 4 - Multifamily] (b)
Exterior Wall 1 copy 7: Concrete Block:8", Partially Grouted, Cells
387 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 7 - Multifamily]
Window 1 copy 2: Metal Frame:Operable, Perf. Specs.: Product ID
30 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 7 - Multifamily] (b)
Window 1 copy 3: Metal Frame:Operable, Perf. Specs.: Product ID
12 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 7 - Multifamily] (b)
Window 1 copy 5: Metal Frame:Operable, Perf. Specs.: Product ID
56 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 7 - Multifamily] (b)
Window 1 copy 4: Metal Frame:Operable, Perf. Specs.: Product ID
9 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 7 - Multifamily] (b)
Exterior Wall 1 copy 9: Concrete Block:8", Partially Grouted, Cells
387 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 10 - Multifamily]
Window 1 copy 4: Metal Frame:Operable, Perf. Specs.: Product ID
30 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 10 - Multifamily] (b)
Window 1 copy 5: Metal Frame:Operable, Perf. Specs.: Product ID
12 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 10 - Multifamily] (b)
Window 1 copy 7: Metal Frame:Operable, Perf. Specs.: Product ID
56 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 10 - Multifamily] (b)
Window 1 copy 6: Metal Frame:Operable, Perf. Specs.: Product ID
9 -- -- 0.500 0.650
Pei iding, 3HGC 0.2G, [Bldg. Use 10 - Multifamily] (b)
Exterior Wall 1 copy 10: Concrete Block:8", Partially Grouted, Cells
387 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 15 - Multifamily]
Window 1 copy 5: Metal Frame:Operable,,Perf. Specs.: Product ID
30 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 15 - Multifamily] (b)
Window 1 copy 6: Metal Frame:Operable, Perf. Specs.: Product ID
12 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 15 - Multifamily] (b)
Window 1 copy 8: Metal Frame:Operable, Perf. Specs.: Product ID
56 -- - 0,500 0.650
Pending, SHGC 0.25, [Bldg. Use 15 - Multifamily] (b)
Window 1 copy 7: Metal Frame:Operable, Perf. Specs.: Product ID
9 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 15 - Multifamily] (b)
Exterior Wall 1 copy 11: Concrete Block:8", Partially Grouted, Cells
387 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 19 - Multifamily]
Window 1 copy 6: Metal Frame:Operable, Perf. Specs.: Product ID
30 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 19 - Multifamily] (b)
Window 1 copy 7: Metal Frame:Operable, Perf. Specs.: Product ID
12 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 19 - Multifamily] (b)
Window 1 copy 9: Metal Frame:Operable, Perf. Specs.: Product ID
56 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 19 - Multifamily] (b)
Window 1 copy 8: Metal Frame:Operable, Pert. Specs.: Product ID
9 --- --- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 19 - Multifamily] (b)
Exterior Wall 1 copy 12: Concrete Block:8", Partially Grouted, Cells
387 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 23 - Multifamily]
Window 1 copy 7: Metal Frame:Operable, Pert. Specs.: Product ID
30 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 23 - Multifamily] (b)
Window 1 copy 8: Metal Frame:Operable, Perf. Specs.: Product ID
12 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 23 - Multifamily] (b)
Window 1 copy 10: Metal Frame:Operable, Perf. Specs.: Product ID
56 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 23 - Multifamily] (b)
Window 1 copy 9: Metal Frame:Operable, Pert. Specs.: Product ID
9 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 23 - Multifamily] (b)
Project Title: 18070 Cristelle Cay Sailfish
Report date: 12/10/18
Data filename: C:\Users�ohnferriter\Documents\COMcheck\18070-Cristelle-Cay-Sailfish.cck Page 6 of 37
Assembly Gross Area Cavity Cont. Proposed Budget U-
or R-Value - R-Value U-Factor Factor(a)
Perimeter
WEST
Exterior Wall 1 copy 3: Concrete Block:8", Partially Grouted, Cells
1044 -- 8.0
0.095 0.123
Empty, Medium Density, Furring: None, [Bldg. Use 1 - Parking Garage]
Exterior Wall 1 copy 7: Concrete Block:8", Partially Grouted, Cells
1350 - 8.0
0.095 0.123
Empty, Medium Density, Furring: None, [Bldg. Use 11 - Parking
Garage]
Exterior Wall 1 copy 7: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0
0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 2 - Multifamily]
Window 1 copy 1: Metal Frame:Operable, Pert. Specs.: Product ID
30 -- -
0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 2 - Multifamily] (b)
Door 1: Insulated Metal, Swinging, [Bldg. Use 2 - Multifamily]
24 - -
0.610 0.610
Exterior Wall 1 copy 8: Concrete Block:8", Partially Grouted, Cells
261 0.0 8.0
0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 3 - Multifamily]
Window 1 copy 2: Metal Frame:Operable, Pert. Specs.: Product ID
30 - --
0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 3 - Multifamily] (b)
Window 1 copy 3: Metal Frame:Operable, Perf. Specs.: Product ID
30 -- -
0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 3 - Multifamily] (b)
Door 1 copy 1: Insulated Metal, Swinging, [Bldg. Use 3 - Multifamily]
24 - --
0.610 0.610
Exterior Wall 1 copy 8: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0
0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 4 - Multifamily]
Window 1 copy 2: Metal Frame:Operable, Perf. Specs.: Product ID
30 -- -
0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 4 - Multifamily] (b)
Door 1 copy 1: Insulated Metal, Swinging, [Bldg. Use 4 - Multifamily]
24 - --
0.610 0.610
Exterior Wall 1 copy 8: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0
0.086 0.151
Empty, Medium Density, Furring; Wood, [Bldg. Use 5 - Multifamily]
Window 1 copy 2: Metal Frame:Operable, Pert. Specs.: Product ID
30 - --
0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 5 - Multifamily] (b)
Door 1 copy 1: Insulated Metal, Swinging, [Bldg. Use 5 - Multifamily]
24 - -
0.610 0.610
Exterior Wall 1 copy 9: Concrete Block:8", Partially Grouted, Cells
261 0.0 8.0
0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 6 - Multifamily]
Window 1 copy 3: Metal Frame:Operable, Perf. Specs.: Product ID
30 - -
0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 6 - Multifamily] (b)
Window 1 copy 4: Metal Frame:Operable, Perf. Specs.: Product ID
30 - -
0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 6 - Multifamily] (b)
Door 1 copy 2: Insulated Metal, Swinging, [Bldg. Use 6 - Multifamily]
24 - -
0.610 0.610
Exterior Wall 1 copy 9: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0
0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 7 - Multifamily]
Window 1 copy 3: Metal Frame:Operable, Perf. Specs.: Product ID
30 - --
0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 7 - Multifamily] (b)
Door 1 copy 2: Insulated Metal, Swinging, [Bldg. Use 7 - Multifamily]
24 - -
0.610 0.610
Exterior Wall 1 copy 10: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0
0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 8 - Multifamily]
Window 1 copy 4: Metal Frame:Operable, Pert. Specs.: Product ID
30 - --
0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 8 - Multifamily] (b)
Door 1 copy 3: Insulated Metal, Swinging, [Bldg. Use 8 - Multifamily]
24 -- --
0.610 0.610
Exterior Wall 1 copy 10: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0
0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 9 - Multifamily]
Window 1 copy 4: Metal Frame:Operable, Perf. Specs.: Product ID
30 - --
0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 9 - Multifamily] (b)
Door 1 copy 3: Insulated Metal, Swinging; [Bldg. Use 9 - Multifamily]
24 -- --
0.610 0.610
Exterior Wall 1 copy 11: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0
0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 10 - Multifamily]
Window 1 copy 5: Metal Frame:Operable, Perf. Specs.: Product ID
30 - -
0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 10 - Multifamily] (b)
Door 1 copy 4: Insulated Metal, Swinging, [Bldg. Use 10 - Multifamily]
24 - --
0.610 0.610
Exterior Wall 1 copy 11: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0
0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 12 - Multifamily]
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\ ohnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish.cck Page 7 of 37
Assembly Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factorm
Perimeter
Window 1 copy 5: Metal Frame:Operable, Perf. Specs.: Product ID
30 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 12 - Multifamily] (b)
Door 1 copy 4: Insulated Metal, Swinging, [Bldg. Use 12 - Multifamily]
24 - - 0.610 0.610
Exterior Wall 1 copy 11: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 13 - Multifamily]
Window 1 copy 5: Metal Frame:Operable, Pert. Specs.: Product ID
30 --- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 13 - Multifamily] (b)
Door 1 copy 4: Insulated Metal, Swinging, [Bldg. Use 13 - Multifamily]
24 -- -- 0.610 0.610
Exterior Wall 1 copy 12: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 14 - Multifamily]
Window 1 copy 6: Metal Frame:Operable, Pert. Specs.: Product ID
30 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 14 - Multifamily] (b)
Door 1 copy 5: Insulated Metal, Swinging, [Bldg. Use 14 - Multifamily]
24 -- - 0.610 0.610
Exterior Wall 1 copy 12: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 15 - Multifamily]
Window 1 copy 6: Metal Frame:Operable, Perf. Specs.: Product ID
30 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 15 - Multifamily] (b)
Door 1 copy 5: Insulated Metal, Swinging, [Bldg. Use 15 - Multifamily]
24 -- - 0.610 0.610
Exterior Wall 1 copy 12: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 16 - Multifamily]
Window 1 copy 6: Metal Frame:Operable, Perf. Specs.: Product ID
30 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 16 - Multifamily] (b)
Door 1 copy 5: Insulated Metal, Swinging, [Bldg. Use 16 - Multifamily]
24 -- - 0.610 0.610
Exterior Wall 1 copy 12: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 17 - Multifamily]
Window 1 copy 6: Metal Frame:Operable, Pert. Specs.: Product ID
30 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 17 - Multifamily] (b)
Door 1 copy 5: Insulated Metal, Swinging, [Bldg. Use 17 - Multifamily]
24 -- - 0.610 0.610
Exterior Wall 1 copy 13: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 18 - Multifamily]
Window 1 copy 7: Metal Frame:Operable, Perf. Specs.: Product ID
30 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 18 - Multifamily] (b)
Door 1 copy 6: Insulated Metal, Swinging, [Bldg. Use 18 - Multifamily]
24 -- - 0.610 0.610
Exterior Wall 1 copy 13: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 19 - Multifamily]
Window 1 copy 7: Metal Frame:Operable, Perf. Specs.: Product ID
30 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 19 - Multifamily] (b)
Door 1 copy 6: Insulated Metal, Swinging, [Bldg. Use 19 - Multifamily]
24 --- -- 0.610 0.610
Exterior Wall 1 copy 13: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 20 - Multifamily]
Window 1 copy 7: Metal Frame:Operable, Perf. Specs.: Product ID
30 -- -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 20 - Multifamily] (b)
Door 1 copy 6: Insulated Metal, Swinging, [Bldg. Use 20 - Multifamily]
24 -- -- 0.610 0.610
Exterior Wall 1 copy 13: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 21 - Multifamily]
Window 1 copy 7: Metal Frame:Operable, Pert. Specs.: Product ID
30 - -- 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 21 - Multifamily] (b)
Door 1 copy 6: Insulated Metal, Swinging, [Bldg. Use 21 - Multifamily]
24 - - 0.610 0.610
Exterior Wall 1 copy 14: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 22 - Multifamily]
Window 1 copy 8: Metal Frame:Operable, Pert. Specs.: Product ID
30 - - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 22 - Multifamily] (b)
Door 1 copy 7: Insulated Metal, Swinging, [Bldg. Use 22 - Multifamily]
24 -- - 0.610 0.610
Exterior Wall 1 copy 14: Concrete Block:8", Partially Grouted, Cells
207 0.0 8.0 0.086 0.151
Empty, Medium Density, Furring: Wood, [Bldg. Use 23 - Multifamily]
Window 1 copy 8: Metal Frame:Operable, Perf. Specs.: Product ID
30 -- - 0.500 0.650
Pending, SHGC 0.25, [Bldg. Use 23 - Multifamily) (b)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070-Cristelle-Cay-5ailfish.cck Page 8 of 37
Assembly
Gross Area Cavity Cont. Proposed Budget U-
or R-Value R-Value U-Factor Factor(.)
Perimeter
Door 1 copy 7: Insulated Metal, Swinging, [Bldg. Use 23 - Multifamily] 24 — — 0.610 0.610
(a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements.
(b) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation.
(c) High albedo roof requirement options: 1) 3-year aged solar reflectance >= 0.55 thermal emittance >= 0.75, 2) 3-year aged solar reflectance
index >= 64.0, 3) Initial year aged solar reflectance >= 0.70 thermal emittance >= 0.75, 4) Initial year aged solar reflectance index >= 82.0.
Enme,lop`e-p• • ••-
Envelope Compliance Statement
Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed envelope systems have been
designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.1.0 and to comply
with an a licable mandatory requirements listed in the Inspection Checklist.
Name - Title Signature Date
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\ ohnferriter\Documents\COMcheck\18070_Cristelle_Cay_Sailfish.cck Page 9 of 37
COMcheck Software Version 4.1.1.0
Interior Lighting Compliance Certificate
Project Information
Energy Code: 2017 Florida Building Code, Energy Conservation
Project Title: 18070 Cristelle Cay Sailfish
Project Type: New Construction
Construction Site: Owner/Agent:
I
Designer/Contractor:
N. Highway AlA David Gilman
Frank Snedaker jr
1/4 Mile South of the Breakers OD I LLC
3015 N. Ocean Blvd
St. Lucie County, FL, FL 34949 6105 Transit Road #140
Suite C-123
Amhirst, NY 14051
Ft. Lauderdale, FL 33308
cardinalsouthern@aol.com
954-561-4455
Additional Efficiency Package(s)
Reduced interior lighting power. Requirements are implicitly enforced within interior lighting
allowance calculations.
Allowed Interior Lighting Power
A
B C
D
Area Category
Floor Area Allowed
Allowed Wafts
(ft2) Wafts / ft2
(B X C)
11-Parking Garage
6938 0.19
1311
1-Parking Garage
5809 0.19
1098
2-Multifamily
1720 0.46
789
3-Multifamily
1678 0.46
770
4-Multifamily
1720 0.46
789
5-Multifamily
1720 0.46
789
6-Multifamily
1678 0.46
770
7-Multifamily
1720 0.46
789
8-Multifamily
1720 0.46
789
9-Multifamily
1678 0.46
770
10-Multifamily
1720 0.46
789
12-Multifamily
1446 0.46
664
13-Multifamily
1448 0.46
665
14-Multifamily
1448 0.46
665
15-Multifamily
1446 0.46
664
16-Multifamily
1446 0.46
664
17-Multifamily
1448 0.46
665
18-Multifamily
1448 0.46
666
19-Multifamily
1446 0.46
664
20-Multifamily
1446 0.46
664
21-Multifamily
1448 0.46
665
22-Multifamily
1448 0.46
665
23-Multifamily
1446 0.46
664
Total Allowed Watts = 17427
Proposed Interior Lighting Power
j
!i
Project Title: 18070 Cristelle Cay Sailfish
Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070_Cristelle Cay_Sailfish.cck
Page 10 of 37
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
G copy 1: G: Other:
1
21
13
273
C4 copy 1: C4: Other:
1
10
21
210
EL copy 1: EL: Other:
1
8
15
120
SL copy 1: SL: Other:
1
16
21
336
1-Parking Garage
C4: C4: Other:
1
12
21
252
G: G: Other:
1
23
13
299
EL: EL: Other:
1
4
15
60
SL: SL: Other:
1
16
21
336
2-Multifamily
F & F1: F & F1: Other:
1
27
13
351
G & G1: G & G1: Other:
1
13
13
169
P: P: Other:
1
15
5
75
3 Multifamily
F & F1 copy 1: F & F1: Other:
1
27
13
351
G & G1 copy 1: G & G1: Other:
1
13
13
169
P copy 1: P: Other:
1
15
5
75
4-Multifamily
F & F1 copy 1: F & F1: Other:
1
27
13
351
G & G1 copy 1: G & G1: Other:
1
13
13
169
P copy 1: P: Other:
1
15
5
75
5-Multifamily
F & F1 copy 1: F & F1: Other:
1
27
13
351
G & G1 copy 1: G & G1: Other:
1
13
13
169
P copy 1: P: Other:
1
15
5
75
6-Multifamily
F & F1 copy 1: F & F1: Other:
1
27
13
351
G & G1 copy 1: G & G1: Other:
1
13
13
169
P copy 1: P: Other:
1
15
5
75
7-Multifamily
F & F1 copy 1: F & F1: Other:
1
27
13
351
G & G1 copy 1: G & G1: Other:
1
13
13
169
P copy 1: P: Other:
1
15
5
75
8-Multifamily
F & F1 copy 1: F & F1: Other:
1
27
13
351
G & G1 copy 1: G & G1: Other:
1
13
13
169
P copy 1: P: Other:
1
15
5
75
Multifamily
F & F1 copy 1: F & F1: Other:
1
27
13
351
G & G1 copy 1: G & G1: Other:
1
13
13
169
P copy 1: P: Other:
1
15
5
75
10-Multifamily
F & F1 copy 1: F & 171: Other:
1
27
13
351
G & G1 copy 1: G & G1: Other:
1
13
13
169
P copy 1: P: Other:
1
15
5
75
12-Multifamily
P copy 1: P: Other:
1
15
5
75
G & G1 copy 1: G & GI: Other:
1
13
13
169
F & F1 copy 1: F & F1: Other:
1
27
13
351
13-Multifamily
P copy 1: P: Other:
1
15
5
75
G & G1 copy 1: G & G1: Other:
1
13
13
169
F & F1 copy 1: F & F1: Other:
1
27
13
351
Project Title: 18070 Cristelle Cay Sailfish
Report date: 12/10/18
Data filename: C:\Users�ohnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish,cck
Page
11 of, 37
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
4-Multifamily
P copy 1: P: Other:
1
15
5
75
G & G1 copy 1: G & G1: Other.
1
13
13
169
F & F1 copy 1: F & F1: Other:
1
27
13
351
15-Multifamily
P copy 1: P: Other:
1
15
5
75
G & G1 copy 1: G & G1: Other:
1
13
13
169
F & F1 copy 1: F & F1: Other:
1
27
13
351
16-Multifamily
P copy 1: P: Other:
1
15
5
75
G & G1 copy 1: G & G1: Other:
1
13
13
169
F & F1 copy 1: F & F1: Other:
1
27
13
351
17-Multifamily
P copy 1: P: Other:
1
15
5
75
G & G1 copy 1: G & G1: Other:
1
13
13
169
F & F1 copy 1: F & F1: Other:
1
27
13
351
18-Multifamily
P copy 1: P: Other:
1
15
5
75
G & G1 copy 1: G & G1: Other:
1
13
13
169
F & F1 copy 1: F & F1: Other:
1
27
13
351
19-Multifamily
P copy 1: P: Other:
1
15
5
75
F & F1 copy 1: F & F1: Other:
1
27
13
351
G & G1 copy 1: G & G1: Other:
1
13
13
169
20-Multifamily
P r..npy 1' P' rlthAr•
1
15
5
75
G & G1 copy 1: G & G1: Other:
1
13
13
169
F & F1 copy 1: F & F1: Other:
1
27
13
351
21-Multifamily
P copy 1: P: Other:
1
15
5
75
G & G1 copy 1: G & G1: Other:
1
13
13
169
F & F1 copy 1: F & F1: Other:
1
27
13
351
22-Multifamily
P copy 1: P: Other:
1
15
5
75
G & G1 copy 1: G & G1: Other:
1
13
13
169
23-Multifamily
P copy 1: P: Other:
1
15
5
75
G & G1 copy 1: G & G1: Other:
1
13
13
169
F & F1 copy 1: F & F1: Other:
1
27
13
351
F & F1 copy 1: F & F1: Other:
1
27
13
351
Total Proposed Watts = 14381
Interior Lighting Compliance Statement
Compliance Statement: The proposed interioo, ` 'rjg design re reA e - Ois document is consistent with the building plans,
specifications, and other calculations submit1ah this perms pp ' re proposed interior lighting systems have been
designed to meet the 2017 Florida Building «dial energy Cons io eMents in COMcheck Version 4.1,1.0 and to comply
with any applicable mandatory requirement!digild ip 1 e Ins t' kl' _ T A
David A. DaSilva, PE #54739 00 0
Name -Title �)7` nAture Date
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users�ohnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish.cck Page 12 of 37
n�(
COMcheck Software Version 4.1.1.0
Exterior Lighting Compliance Certificate
Project Information
Energy Code:
Project Title:
Project Type:
Exterior Lighting Zone
Construction Site:
N. Highway AIA
1/4 Mile South of the Breakers
St. Lucie County, FL, FL 34949
Allowed Exterior Lighting Power
2017 Florida Building Code, Energy Conservation
18070 Cristelle Cay Sailfish
New Construction
2 (Residentially zoned area)
Owner/Agent:
David Gilman
OD I LLC
6105 Transit Road #140
Amhirst, NY 14051
cardinalsouthern@aol.com
Designer/Contractor:
Frank Snedaker jr
3015 N. Ocean Blvd
Suite C-123
Ft. Lauderdale, FL 33308
954-561-4455
A
Area/Surface Category
B
Quantity
C D
Allowed Tradable
Watts / Unit Wattage
E
Allowed Watts
(B X C)
Parking area
7375 ft2
0.06 Yes
442
Walkway < 10 feet wide
2900 ft of
0.7 Yes
2030
Parking area
8636 ft2
0.06 Yes
518
Walkway < 10 feet wide
3528 ft of
0.7 Yes
2470
Total Tradable Watts (a) =
5460
Total Allowed Watts =
5460
Total Allowed Supplemental Watts (b) =
600
(a) Wattage tradeoffs are only allowed between tradable areas/surfaces.
(b) A supplemental allowance equal to 600 watts may be applied toward compliance of both non -tradable and tradable areas/surfaces.
Proposed Exterior Lighting Power
A B C D E
Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D)
Fixture Fixtures Watt.
Parking area (7375 ft2): Tradable Wattage
X: X: Other:
Walkway < 10 feet wide (2900 ft of walkway length): Tradable Wattage
W: W: Other:
Parking area (8636 ft2): Tradable Wattage
X copy 1: X: Other:
Walkway < 10 feet wide (3528 ft of walkway length): Tradable Wattage
W copv 1: W: Other:
Exterior Lighting PASSES: Design 65°/a better than -code
Exterior Lighting Compliance Statement.
9
50
450
25
30
750
7
50
350
1 20 30 600
Total Tradable Proposed Watts = 2150
Compliance Statement: The proposed exterior lighting design represented in this document is consistent with the building plans,
specifications, and other calculations submitted with this permit application. The proposed exterior lighting systems have been
designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.1.1.0 and to comply
with any applicable mandatory requirements listed In the Inspection Checklist.
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070_Cristelle_Cay_Sailfish.cck Page 13 of 37
vid A. DaSilva, PE #54739 N
me - Title idndeure • 4?3g : G
�0 =
STATE
z OF
,,//1o�/gLI E14G\�\`�
Date
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070_Cristelle_Cay_Sailfish.cck Page 14 of 37
COMcheck Software Version 4.1.1.0
Mechanical Compliance Certificate
Project Information
Energy Code: 2017 Florida Building Code, Energy Conservation
Project Title: 18070 Cristelle Cay Sailfish
Location: Vero Beach, Florida
Climate Zone: 2a
Project Type: New Construction
Construction Site:
N. Highway AlA
1/4 Mile South of the Breakers
St. Lucie County, FL, FL 34949
Owner/Agent:
David Gilman
OD I LLC
6105 Transit Road *140
Amhirst, NY 14051
cardinalsouthern@aol.com
Designer/Contractor:
Frank Snedaker jr
3015 N. Ocean Blvd
Suite C-123
Ft. Lauderdale, FL 33308
954-561-4455 .
Additional Efficiency Package(s)
Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations.
Mechanical Systems List
Quantity System Type & Description
18 HVAC System 1 (Single Zone):
Heating: 1 each - Unit Heater, Electric, Capacity = 24 kBtu/ti
No minimum efficiency requirement applies
Cooling: 1 each - Split System, Capacity = 36 kBtu/h, Air -Cooled Condenser, No Economizer, Economizer exception: Low Capacity
Residential
Proposed Efficiency = 16.00 SEER, Required Efficiency: 13.00 SEER
Fan System: FAN SYSTEM 1 — Compliance (Motor nameplate HP method) : Passes
Fans:
FAN 1 Supply, Constant Volume, 1250 CFM, 0.5 motor nameplate hp, 0.0 fan efficiency grade
HVAC System 1 copy 1 (Single Zone):
Heating: 1 each - Unit Heater, Electric, Capacity = 24 kBtu/h
No minimum efficiency requirement applies
Cooling: 1 each - Split System, Capacity = 50 kBtu/h, Air -Cooled Condenser, No Economizer, Economizer exception: Low Capacity
Residential
Proposed Efficiency =16.00 SEER, Required Efficiency: 13.00 SEER
Fan System: FAN SYSTEM 2 — Compliance (Motor nameplate HP method) : Passes
Fans:
FAN 2 Supply, Constant Volume, 1600 CFM, 0.5 motor nameplate hp, 0.0 fan efficiency grade
HVAC System 3 (Single Zone):
VRF Condensing Unit, Air Cooled Heat Pump
Heating Mode: Capacity = 7 kBtu/h,
Proposed Efficiency = 10.00 HSPF, Required Efficiency = 7.70 HSPF
Cooling Mode: Capacity = 6 kBtu/h,
Proposed Efficiency = 19.00 SEER, Required Efficiency: 13.00 SEER
Fan System: Unspecified
HVAC System 4 (Single Zone):
VRF Condensing Unit, Air Cooled Heat Pump
Heating Mode: Capacity = 14 kBtu/h,
Proposed Efficiency = 10.00 HSPF, Required Efficiency = 7.70 HSPF
Cooling Mode: Capacity = 12 kBtu/h,
Proposed Efficiency = 20.00 SEER, Required Efficiency: 13.00 SEER
Fan System: Unspecified
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\UsersVohnferriter\Documents\COMcheck\18070 Cristelle—Cay_Sailfish.cck Page 15 of 37
Quantity System Type & Description
1 HVAC System 5 (Single Zone):
VRF Condensing Unit, Air Cooled Heat Pump
Heating Mode: Capacity = 28 kBtu/h,
Proposed Efficiency = 10,00 HSPF, Required Efficiency = 7.70 HSPF
Cooling Mode: Capacity = 23 kBtu/h,
Proposed Efficiency = 19.00. SEER, Required Efficiency: 13.00 SEER
Fan System: Unspecified
24 HVAC System 7 (Single Zone):
Split System Heat Pump
Heating Mode: Capacity = 6 kBtu/h,
Proposed Efficiency = 10.00 HSPF, Required Efficiency = 8.20 HSPF
Cooling Mode: Capacity = 7 kBtu/h,
Proposed Efficiency = 19.00 SEER, Required Efficiency: 14.00 SEER
Fan System: FAN SYSTEM 3 — Compliance (Motor nameplate HP method) : Passes
Fans:
FAN 3 Supply, Constant Volume, 399 CFM, 0.2 motor nameplate hp, 0.0 fan efficiency grade
HVAC System 7 copy 1 (Single Zone):
Split System Heat Pump
Heating Mode: Capacity = 12 kBtu/h,
Proposed Efficiency = 10.00 HSPF, Required Efficiency = 8.20 HSPF
Cooling Mode: Capacity = 14 kBtu/h,
Proposed Efficiency = 20.00 SEER, Required Efficiency: 14.00 SEER
Fan System: FAN SYSTEM 3 — Compliance (Motor nameplate HP method) : Passes
Fans:
FAN 3 Supply, Constant Volume, 399 CFM, 0.2 motor nameplate hp, 0.0 fan efficiency grade
HVAC System 7 copy 2 (Single Zone):
Split System Heat Pump
Heating Mode: Capacity — 28 kBtu/h,
Proposed Efficiency = 10.00 HSPF, Required Efficiency = 8.20 HSPF
Cooling Mode: Capacity = 23 kBtu/h,
Proposed Efficiency = 19.00 SEER, Required Efficiency: 14.00 SEER
Fan System: FAN SYSTEM 3 — Compliance (Motor nameplate HP method) : Passes
Fans:
FAN 3 Supply, Constant Volume, 399 CFM, 0.2 motor nameplate hp, 0.0 fan efficiency grade
1111111
Mechanical Compliance Statement \\\\\ \ ���AN //�,
Compliance Statement: The proposed mechanic�Y rl����rep a e . a41 t4s document is consistent with the building plans,
specifications, and other calculations submitted�nrit� s pe I1 io he proposed mechanical systems have been
designed to meet the 2017 Florida Building Cc;Zl Energy e a I$ta'r iraments in COMcheck Version 4. .1.0 a d to comply
with any applicable mandatory requirementq�sbddn the tion i; ' t= /[
David A. DaSiiva, PE #54739 -
Name - Title — -tt • Signature D to
/l�jO • FOR/p �F . �(��\ .
;l111110
ENG1��\��
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070-Cristelle Cay_Saiifish.cck Page 16 of 37
COMcheck Software Version 4.1.1.0
Inspection Checklist
Energy Code: 2017 Florida Building Code, Energy Conservation
Requirements; 0.0% were addressed directly in the COMcheck software
Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section
#
Plan Review.
Complies?
Comments/Assumptions
,& Re. .ID.
C103.2
,Plans and/or specifications provide all
;❑Complies
[PRl)1
information with which compliance
;❑Does Not
can be determined for the building
i envelope and document where
❑Not Observable
exceptions to the standard are
;❑Not Applicable
claimed.
C103.2
;Plans, specifications, and/or
;❑Complies ;
[PR2)1
:calculations provide all information
;❑Does Not
with which compliance can be
determined for the mechanical
UNot Observable
systems and equipment and
:❑Not Applicable
I document where exceptions to the
;
:standard are claimed. Load
;
calculations per acceptable
,
;engineering standards and
;
,handbooks.
;
C405.6
'Plans, specifications, and/or
UComplies
[PR17)1
!calculations provide all information
;❑Does Not
;with which compliance can be
;determined for the electrical systems
;❑Not Observable
:and equipment and document where
;❑Nat Applicable
:exceptions are claimed. Provisions are
!made for metering individual tenant
;
!units. Feeder connectors (for feeder
:and branch circuits) sized in
:accordance with approved plans with
:
i maximum drop of 5% voltage drop
!total.
C103.2
!Plans, specifications, and/or
;❑Complies ;
[PR4)1
!calculations provide all information
;❑Does Not
;with which compliance can be
{determined for the interior lighting
'I❑Not
I []Not Observable _
Applicable
:and electrical systems and equipment
;
and document where exceptions to
!the standard are claimed. Information
{provided should include interior
! :
:lighting power calculations, wattage of;
.
bulbs and ballasts, transformers and
; I
control devices.
C103.2
!Plans, specifications, and/or
!❑Complies
[PR8)1
!calculations provide all information
;❑Does Not
;with which compliance can be
determined for the exterior lighting
;❑Not Observable
and electrical systems and equipment
:❑Not Applicable ;
and document where exceptions to
ithe standard are claimed. Information
provided should include exterior
lighting power calculations, wattage of;
!bulbs and ballasts, transformers and
I :
: control devices.
111 High Impact (Tier 1) ' 2 1 Medium Impact (Tier 2) :3 1 Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users�ohnferriter\Documents\COMcheck\18070_Cristelle_Cay_Sailfish.cck Page 17 of 37
Section
# Plan ReVlew
, ,
Complies
`Comments/Assumptions
& Re 'ID
C402.4.1 ;The vertical fenestration area <= 30 ;❑Complies ;J
[PR10]1 :percent of the gross above -grade wall :❑Does Not
area. �❑Not Observable
❑Not Applicable
C402.4.1 ;The skylight area <= 3 percent of the 1❑Complies
[PR11]1 gross roof area. :❑Does Not
I
❑Not Observable
j '❑Not Applicable
C402.4.2 ;In enclosed spaces > 2,500 ft2 ;❑Complies
[PR14]1 !directly under a roof with ceiling ❑Does Not
heights >15 ft. and used as an office, 1
Observable;
lobby, atrium, concourse, corridor, ;❑Not
:storage, gymnasium/exercise center, []Not Applicable
;convention center, automotive
;service, manufacturing, non- i
refrigerated warehouse, retail store,
;distribution/sorting area,
'transportation, or workshop, the I
lfollowing requirements apply: (a) the
:daylight zone under skylights is >_
i half the floor area; (b) the skylight I
:area to daylight zone is >= 3 percent
with a skylight VT >= 0.40; or a
1 minimum skylight effective aperture
>= 1 percent.
C406 ,Plans, specifications, and/or ElComplies
[PR9]1 :calculations provide all information :❑Does Not
;with which compliance can be
Observable 1
1 determined for the additional energy ;❑Not
!efficiency package options. ;❑Not Applicable ;
C402.5.9.(iCeilings with vented dropped ceiling ;❑Complies ;
1-4) :cavities over conditioned spaces have :❑Does Not
[PR16]1 ;a continuous air barrier between the
❑Not Observable
,conditioned space and the vented
i unconditioned space and are sealed to I❑Not Applicable ;
;the air barrier of the walls. Unvented
'dropped ceiling cavities over
conditioned spaces without air barrier
between the conditioned and
I unconditioned space are sealed from i
:the exterior environment and adjacent;
:spaces by a continuous air barrier and
1 is sealed to the air barrier of the walls. 1
; Unconditioned spaces above separate
;tenancies contain dividing partitions
:between the tenancies to form a 1
continuous air barrier that is sealed at
;the ceiling and roof. Building cavities ;
i designed to be air distribution system 1
;components are sealed according to
1 the criteria for air ducts, plenums, etc. ; 1
1 in Section C403.2.7.
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 2' Medium Impact (Tier 2) 1`'3'1 Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070 Cristelle_Cay_Sai[fish.cck Page 18 of 37
#_ Footing,/ Foundation ,Inspection
--Complies?'
Comments/Assumptions
Re .11)
C303.2.1 'Exterior insulation protected against
;❑Complies
[FO6]1 :damage, sunlight, moisture, wind,
:❑Does Not
;landscaping and equipment
Observable i
maintenance activities.
.❑Not
;❑Not Applicable
C403:2.4. 1 Snow/ice melting system sensors for
;❑Complies
5, , - Ifuture connection to controls. Freeze
:❑Does Not
C403.2.4. ; protection systems have automatic
6
. controls installed.
;❑Not Observable:
;❑Not Applicable ;
[F0:9]3• ;+
Additional Comments)Assumptions:
111 High Impact (Tier 1) Z Medium Impact (Tier 2) 3` 1 Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish.cck Page 19 of 37
Section
#:
Framing / Rough in Inspection
`Co-Comments/Assumptlons
&(•Re .ID
C303.1 3.'-1Fenestration products rated in
;❑Complies
.';accordance with NFRC.
;❑Does Not
'❑Not Observable ;
❑Not Applicable
C303.1.3 ;Fenestration products are certified as '.❑Complies
[FR13]1 to performance labels or certificates
;❑Does Not
provided.
;❑Not Observable:
❑Not Applicable
C402.4.3 ;Vertical fenestration SHGC value.
;❑Complies ;See the Envelope Assemblies table for values.
[FR10]1
;❑Does Not
❑Not Observable;
❑Not Applicable
C402.4.3, i Vertical fenestration U-Factor.
;❑Complies ;See the Envelope Assemblies table for values.
C402.4.3.
UDoes Not
4 1
[FR8]
UNot Observable:
:[--]Not Applicable
;C402:4:4 .I U-factor of opaque doors associated
;❑Complies ;See the Envelope Assemblies table for values.
[FR14] - :with the building thermal envelope
❑Does Not
,meets requirements.
i❑Not Observable:
•;
;❑Not Applicable
C402.5.1 ;The building envelope contains a
I❑Compiles
[FR16]1 i continuous air barrier that is sealed in
E❑Does Not
:an approved manner and either
!constructed or tested in an approved
;❑Not Observable:
manner. Air barrier penetrations are
:❑Not Applicable ;
;sealed in an approved manner.
C402.5.2, ; Factory -built fenestration and doors
;❑Complies
C402:5:4 !are labeled as meeting air leakage
;❑Does Not
[FR8]3 requirements.
;❑Not Observable;
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact (Tier 1) 2 Medium Impact (Tier 2) 3:. Low impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070_Cristelle Cay_Sailfish.cck Page 20 of 37
Section
#' Plumbing,Rough-ln inspectl'on
: Complies?
Comments/Assumptions
-Re :ID
C404.51 ; Heated water supply piping conforms {❑Complies
C404.5.1, !to pipe length and volume UDoes Not
C404.5.2 requirements. Refer to section details.
[PIL6]3 ,❑Not Observable ;
Z❑Not Applicable
I
C404.5; , Heated water supply piping conforms ;❑Complies ;
C404.5.1, ito pipe length and volume :❑Does Not
C404.5.2 { requirements. Refer to section details. ;❑Not Observable;
[PL6]3 �❑Not Applicable
C404.5, • ; Heated water supply piping conforms ;❑Complies ;
C404.5.1,• Ito pipe length and volume ;❑Does Not
C404;5.2 i requirements. Refer to section details.
;❑Not Observable;
[PL6]3.
❑Not Applicable
C404.5; ' ; Heated water supply piping conforms ;❑Complies
C404.5,1, !to pipe length and volume ;❑Does Not
C404.5.2 requirements. Refer to section details. ;
[PL6]3 ' ..S :❑Not Observable;
;❑Not Applicable
C404,5, Heated water supply piping conforms ;❑Complies ;
C404.5.1, 'to pipe length and volume ;❑Does Not
C404.5.2_ ; requirements. Refer to section details. ;
[PL6]3. I :❑Not Observable ;
❑Not Applicable
C404.5, • ':!Heated water supply piping conforms ;❑Complies ;
C404.5.1;':Ito pipe length and volume ;❑Does Not
C404.5.2 '.; requirements. Refer to section details. ;❑Not Observable ;
[PL6]3.
,
❑Not Applicable ;
C404:5; • ,Heated water supply piping conforms ;❑Complies
C404.5" * ,fto pipe length and volume :❑Does Not
C404..5.2 ,;I requirements. Refer to section details.
:[--]Not Observable:
E ;❑Not Applicable ;
C464:5, : `°; Heated water supply piping conforms ;❑Complies ;
C404.5.1, Ito pipe length and volume ;❑Does Not i
C404:5.2 i requirements. Refer to section details.
Observable:
[PL6:]3 ,❑Not
_I ;❑Not Applicable ;
.,
C404,6,3 , Pumps that circulate water between a ;❑Complies ;
[PL7]3 heater and storage tank have controls ;❑Does Not
that limit operation from startup to
<= 5 minutes after end of heating ;❑Not Observable;
cycle. ;❑Not Applicable ;
.C404.63 .I Pumps that circulate water between a ;❑Complies
[PL;"7]3 a heater and storage tank have controls E❑Does Not
Athat limit operation from startup to ;
'I <= 5 minutes after end of heating -]Not Observable
cycle, ;❑Not Applicable ;
C404,6.3' !Pumps that circulate water between a ;❑Complies
[PL7]3 ;� heater and storage tank have controls T❑Does Not
:that limit operation from startup to ❑Not Observable
<= 5 minutes after end of heating ;
cycle. ,❑Not Applicable ;
11 High Impact (Tier 1) 1,2J Medium Impact (Tier 2) �•3 1 Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish.cck Page 21 of 37
Secfion
#;,
PIum6ing Rough In.lhspectiorr
Complies?
Comments/Assumpfiions
Re .ID
h
C404:6.3 !Pumps that circulate water between a EComplies
[PL7]3 heater and storage tank have controls ;❑Does Not
;that limit operation from startup to ;
❑Not Observable
<= 5 minutes after end of heating
cycle. ;❑Not Applicable ,
C404.6.3 !,Pumps that circulate water between a ;❑Complies
[PL7]3 ;heater and storage tank have controls ;❑Does Not
that limit operation from startup to ;
Observable
<= 5 minutes after end of heating ;❑Not
i cycle. ;❑Not Applicable ;
C404.6.3 'Pumps that circulate water between a ;❑Complies
[PL7,]3 !heater and storage tank have controls ;❑Does Not
;that limit operation from startup to ; ;
❑Not Observable
<= 5 minutes after end of heating
,Icycle. ;❑Not Applicable ;
C404.6.3 I Pumps that circulate water between a ;❑Complies ;
[PL7]3 ; heater and storage tank have controls ;❑Does Not
;that limit operation from startup to
; <= 5 minutes after end of heating �❑Not Observable
Icycle. ;❑Not Applicable ;
C404.6.3 ; Pumps that circulate water between a I❑Complies
[PL7]3 and storage tank have controls ;❑Does Not
.;heater
that limit operation from startup to ;❑Not Observable;
<= 5 minutes after end of heating
Icycle. ;❑Not Applicable
C404.7 ; Water distribution system that pumps ;❑Complies ;
[PL8]3 :water from a heated -water supply ;❑Does Not
; pipe back to the heated -water source
❑Not Observable;
;through a cold -water supply pipe is a
demand recirculation water system. �❑Not Applicable
,;Pumps within this system have ;
.;controls that start the pump upon ;
:receiving a signal from the action of a
fuser of a fixture or appliance and ;
."limits the temperature of the water ; I
centering the cold -water piping to
;104°F. ;
C404.7 !Water distribution system that pumps ;❑Complies
.,,;water from a heated -water supply ❑Does Not
A pipe back to the heated -water source ;❑Not Observable
,.through a cold -water supply pipe is a
;❑Not Applicable
I demand recirculation water system.
Pumps within this system have
:controls that start the pump upon
:.... - : J receiving a signal from the action of. a I
user of a fixture or appliance and
;limits the temperature of the water
entering the cold -water piping to I ;
104°F.
C404:7 _.. ; Water distribution system that pumps ;❑Complies
[RL8]3 !water from a heated -water supply :[]Does Not
; pipe back to the heated -water source ;❑Not Observable
;through a cold -water supply pipe Is a
`demand recirculation water system. I❑Not Applicable ;
Pumps within this system have ;
1 controls that start the pump upon ; I
receiving a signal from the action of a
user.of a fixture or appliance and ;
; limits the temperature of the water
(entering the cold -water piping to
104°F.
111 High Impact (Tier 1) '7•; Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish.cck Page 22 of 37
Section.
#
Plumbing Rough-In'I'nspection'
- Complies
Comments/Assumptions
-& Re :ID
C404.7
I Water distribution system that pumps !❑Complies
[PL8]3 . '
;water from a heated -water supply 1❑Does Not
pipe back to the heated -water source 1❑Not Observable',
;through a cold -water supply pipe is a
demand recirculation water system. I❑Not Applicable
j Pumps within this system have
i controls that start the pump upon ;
receiving a signal from the action of a j
; user of a fixture or appliance and ;
f limits the temperature of the water
entering the cold -water piping to
104°F.
C404.7,' Water distribution system that pumps ;❑Complies ;
[PL8]3 i water from a heated -water supply j❑Does Not
pipe back to the heated -water source
;through a cold -water supply pipe is a ❑Not Observable:
!demand recirculation water system. ❑Not Applicable
Pumps within this system have
controls that start the pump upon
•i receiving a signal from the action of a 1
user of a fixture or appliance and
I limits the temperature of the water
entering the cold -water piping to
104°F.
C404.7.. ; Water distribution system that pumps ;❑Complies
[PL8]3 .! water from a heated -water supply ;❑Does Not
pipe back to the heated -water source ;
';through a cold -water supply pipe is a ;❑Not Observable:
i demand recirculation water system. ;[]Not Applicable ;
i Pumps within this system have
' controls that start the pump upon ;
receiving a signal from the action of a I
user of a fixture or appliance and
the temperature of the water ; I
centering the cold -water piping to
_
104°F. '
C404.7-' "; Water distribution system that pumps ;❑Complies ;
[PL8]3 ,. „ .,water from a heated -water supply ;❑Does Not
pipe back to the heated -water source ;❑Not Observable ;
'
through a cold -water supply pipe is a
4 demand recirculation water system. ;❑Not Applicable ;
Pumps within this system have
j controls that start the pump upon ;
".I receiving a signal from the action of a
j user of a fixture or appliance and
limits the temperature of the water ;
i entering the cold -water piping to
104°F.
C404:7''" ; Water distribution system that pumps ;❑Complies ;
[PL8]3 ;' • 'water from a heated -water supply :❑Does Not
pipe back to the heated -water source
❑Not Observable
;through a cold -water supply pipe is a
i demand recirculation water system. 1E]Not Applicable
,Pumps within this system have
controls that start the pump upon ;
receiving a signal from the action of a
user of a fixture or appliance and
j limits the temperature of the water
:;entering the cold -water piping to
1104* F.
Additional Comments/Assumptions:
111 High Impact (Tier 1) ' 2 �J Medium Impact (Tier 2) 5 1 Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070_Cristelle Cay_Sai[fish.cck Page 23 of 37
11 High Impact (Tier 1) 2,< Medium Impact (Tier 2) 3; Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070 Cristelle_Cay_Sailfish.cck Page 24 of 37
Section
#. Mechanical Rough-ln fnspection „
- Complies?
Comments/Assumptions
�,&;Re1q.tD'
;
C402,2.6 :;Thermally Ineffective panel surfaces of;❑Complies
[ME41]3 Isensibie heating panels have
;❑Does Not
,insulation >= R-3.5.
❑Not Observable'
„ ..;
;❑Not Applicable
C402.5.5, l Stair and elevator shaft vents have
;❑Complies
C403.2.4, 1 motorized dampers that automatically
:❑Does Not
3 - ;close.
[.ME3]3 , 'j
;❑Not Observable;
❑Not Applicable
;
C403.2.12 { HVAC fan systems at design
;❑Complies ;See the Mechanical Systems list for values.
1 :conditions do not exceed allowable
:❑Does Not
[ME65]3 ;fan system motor nameplate hp or fan
;❑Not Observable;
system bhp.
;❑Not Applicable
C403.2.12 ; HVAC fan systems at design
;❑Complies :See the Mechanical Systems list for values.
.1it conditions do not exceed allowable
UDoes Not
[ME65]3. ;fan system motor nameplate hp or fan
;❑Not Observable ;
,;system bhp.
A
;[]Not Applicable ;
C403.2.12 HVAC fan systems at design
;❑Complies ;See the Mechanical Systems list for values.
1 :!conditions do not exceed allowable
;❑Does Not
[ME65]3 fan system motor nameplate hp or fan
Not Observable;
;❑1
:+ system bhp.
❑Not Applicable
C403.2.12` Fans have efficiency grade (FEG) >=
;❑Complies
1'67. The total fan at
,j
Not
;
[M117]z he design point of operation <15%
,E
►of maximum total efficiency of the
❑Not Observable;
;fan.
�ONot Applicable
;C403,2,121 Fans have efficiency grade (FEG) >=
.3: The total efficiency of the fan at
;❑Complies ;
;❑Does
167.
[ME117]z. ;,the design point of operation <= 15%
lof
Not
Observable;
maximum total efficiency of the
;❑Not
'❑Not Applicable
fan.
;
C403.2.12-1Fans have efficiency grade (FEG) >=
;❑Complies ;
1.3 '. ;67. The total efficiency of the fan at
❑Does Not
:[ME117]2 ;the design point of operation <= 15%
;
Observable:
Of maximum total efficiency of the
;❑Not
Applicable
fan,
;❑Not ;
;G403.2:9. `
HVAC ducts and plenums insulated
;❑Complies
1.111: . • ' ;land
sealed according to Florida
;❑Does Not
[ME60]? .
Section C403.2.9, Table C403.2.9.1.
;❑Not Observable;
❑Not Applicable
All ducts, air handlers, filter boxes,
;❑Complies
2., ;building cavities, mechanical closets
;❑Does Not
[ME79]z J and enclosed support platforms that
; Observable
form the primary air containment
passageways for air distribution
;❑Not
;❑Not Applicable ;
;systems are constructed and erected
in accordance with Table C403.2.9.2
'and with Chapter 6 of the Florida
1
,Building Code, Mechanical. Ducts are
be constructed, braced, reinforced
;
i and installed to provide structural
- ;strength and durability. All transverse
Jjoints, longitudinal seams and fitting
connections. are securely fastened in
;accordance
with the applicable
standards of this section.
;
111 High Impact (Tier 1) It, 2 Medium Impact (Tier 2) 1 3-,J Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users�ohnferriter\Documents\COMcheck\18070 Cristelle_Cay_Sailfish.cck Page 25 of 37
Section
#;
Mechanical Rough In In'spection
CompheS2
h Co m/A mentsssumptions
& Re' ID
C4032'.9::; Duct insulation is protected from
;❑Complies
1.2 `' ': ", damage but not limited to the
;❑Does Not
[ME80]?'; ;following: 1. Insulation exposed to
;❑Not Observable)
weather is suitable for outdoor
;❑Not Applicable ;
service. Cellular foam insulation is
protected or painted with a coating
;that is water retardant and provides
;
'shielding from solar radiation. 2.
Insulation covering cooling ducts
:'-"' located outside the conditioned space
;
E is vapor retardant located outside the
insulation, all penetrations and joints
;
of which shall be sealed.
C403.29. ,Additional insulation with vapor
;❑Complies
1.3- -. , . _- -'I barrier is provided where the
:[]Does Not
[ME81]?.,; '? minimum duct insulation requirements,❑Not
of Section C403.2.9.1.1 are
Observable
determined to be insufficient to
I❑Not Applicable ;
prevent condensation.
1
C4012.11), Unenclosed spaces that are heated
;❑Complies
[ME71 .. ;:! use only radiant heat.
;❑Does Not
i
i❑Not Observable:
;❑Not Applicable
'C403.2:3 ; HVAC equipment efficiency verified.
;❑Complies ;See the Mechanical Systems list for values.
[ME55]?•...
;❑Does Not
•;
;❑Not Observable;
_
❑Not Applicable
C403'2.9'. -; Ducts, air handlers, filter boxes,
;❑Complies ;
'',31,''`F'::, 'jbuilding cavities, mechanical closets
;❑Does Not
{ME10.]?" 'and enclosed support platforms that
❑Not Observable
form the primary air containment
passageways for air distribution
;❑Not Applicable
?;systems are sealed in accordance with;
"'. the applicable criteria of this section
i and Table C403.2.9.2.
C403.2 9..,1,Cavities in framed spaces are not ;❑Complies
`
4 ','°,. ', used to deliver air from or return air to
:❑Does Not
[ME78j? -; Ithe conditioning system unless they
;contain an air duct insert which is
UNot Observable;
1 insulated in accordance with Section
;❑Not Applicable ;
C403.2.9.1 and constructed and
,
?sealed in accordance with the
;
j requirements of Section C403.2.9.2
appropriate for the duct materials
,used.
;
;C403:2;9.- ;Air distribution systems are sized and ;❑Complies
'`.; designed in accordance with
(ME76']?`;recognized engineering standards.
![]Does Not
i Refer to section details.
❑Not Observable;
:❑Not Applicable
C463:2'9. •;Air -handling units not installed in
;❑Complies
6' +,,.'`- attics of commercial buildings.
;❑Does Not a
jME77]? ,
;❑Not Observable;
❑Not Applicable
11 High Impact (Tier 1) 2' Medium Impact (Tier 2) -,3, Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070 Cristelle_Cay_Sailfish.cck Page 26 of 37
ec#tion..:__;.-;
Rpn
,c
ie
Comments/Assumptions.°Mech-
.
:&SRe .ID:
C408.2.2.
Wr system balancing accomplished in
;❑Complies
1
!a manner to first minimize throttling
;❑Does Not
[ME53]3
ilosses,then for fans with fan system
1❑Not Observable;
power greater than 1 hp, fan speeds
tshall be adjusted to meet design flow
�❑Not Applicable ;
;conditions. Balancing procedures shall
;
be in accordance with NEBB
;
1Procedural Standards, the AABC,
National Standards, or equivalent
1procedures.
C403.2.6, ;Demand control ventilation provided
;❑Complies ;
❑Does Not
[ME59]1 ; people/1000 ft2 occupant density and
Observable;
;served by systems with air side
;economizer, auto modulating outside
1❑Not
;❑Not Applicable ;
:air damper control, or design airflow
>3,000 cfm.
;
C403.2.6..!Enclosed parking garage ventilation
;❑Complies ;
.2 `,1 has automatic contaminant detection
;❑Does Not
[ME115]3 }and capacity to stage or modulate
;fans to 50% or less of design capacity.
;❑Not Observable I
,;
�❑Not Applicable
C403.2.7 :Exhaust air energy recovery on
;❑Complies
[ME57]1 !systems meeting Table C403.2.7(1)
:❑Does Not
;and C403,2.7(2).
;[]Not Observable;
;❑Not Applicable
C403.2.8 Kitchen exhaust systems comply with
;❑Complies ;
[ME116,]3 1 replacement air and conditioned
;❑Does Not
.Isupply air limitations, and satisfy hood
;Observable;
rating requirements and maximum
❑Not
%;exhaust rate criteria.
;❑Not Applicable ;
C403.4.4. ; Multiple zone VAV systems with DDC
;❑Complies ;See the Mechanical Systems list for values.
6 - (of individual zone boxes have static
;❑Does Not
[ME110]3 ;pressure setpoint reset controls.
❑Not Observable;
;❑Not Applicable
C403.4•c4'.• J Multiple zone VAV systems with DDC
:.❑Complies ;See the Mechanical Systems list for values.
6 iof individual zone boxes have static
;❑Does Not
[ME110]3' ':pressure setpoint reset controls,
; ❑Not Observable ;
j
;❑Not Applicable
Multiple zone VAV systems with DDC
;❑Complies ;See the Mechanical Systems list for values.
6, of individual zone boxes have static
'[ME110]3.. '� pressure setpoint reset controls.
;❑Does Not
,❑Not Observable:
{
❑Not Applicable
C4
. 93.4.4-4, Multiple zone VAV systems with DDC
;❑Complies ;See the Mechanical Systems list for values.
6 . '" ' `; of individual zone boxes have static
:❑Does Not
[MET10]3' .; pressure setpoint reset controls.
❑Not Observable;
❑Not Applicable
C403.4,4; ;Multiple zone VAV systems with DDC
;,[]Complies ;See the Mechanical Systems list for values.
6 of individual zone boxes have static
;❑Does Not
[ME11V. ; pressure setpoint reset controls.
❑Not Observable;
i❑Not Applicable
C403.4:4. ; Multiple zone VAV systems with DDC
;❑Complies ;See the Mechanical Systems list for values.
'6. ." ' .`�1of individual zone boxes have static
;❑Does Not
[ME110]3' ;;pressure setpoint reset controls.
I❑Not Observable;
;❑Not Applicable
111 High Impact (Tier 1) 2,: Medium Impact (Tier 2) -.3 I Low Impact (Tier 3)
Project Title: 18070 Cristeile Cay Sailfish Report date: 12/10/18
Data filename: C:\Users�ohnferriter\Documents\COMcheck\18070_Cristelle_Cay_Sailfish.cck Page 27 of 37
Sectlon r -
#_ Mechanical Rough In Inspection
-Complies?
Comments/Assumptions
&•Re ID
x
-
C403.4.4. :Multiple zone VAV systems with DDC
:❑Complies ;See the Mechanical Systems list for values.
6 :of individual zone boxes have static
;❑Does Not
[ME110]3 `pressure setpoint reset controls.
❑Not Observable;
❑Not Applicable
C403.4.4. :,Multiple zone VAV systems with DDC
:❑Complies ;See the Mechanical Systems list for values.
6 :of individual zone boxes have static
:❑Does Not
[ME110]3 pressure setpoint reset controls.
I
:[--]Not Observable
❑Not Applicable
C408,2.2. %Air outlets and zone terminal devices
:❑Complies ;
1 have means for air balancing.
;❑Does Not
[ME53]3 I
;❑Not Observable:
❑Not Applicable
C403.5, ;Refrigerated display cases, walk-in
;❑Complies
C403,5,1, (coolers or walk-in freezers served by
:,❑Does Not
C403.5.2 ; remote compressors and remote
[ME123]3 I condensers not located in a
.❑Not Observable
•condensing unit, have fan -powered
ZINot Applicable
condensers that comply with Sections
'C403.5.1 and refrigeration compressor;
!systems that comply with C403.5.2..
C403.5.3 ;Condensing coils installed in cool air
;❑Complies
[ME124]3 :stream of another air-conditioning
%❑Does Not
!unit. The condensing coil of one air-
conditioning unit shall not be installed
%❑Not Observable;
; ;
I in the cool air stream of another air-
:❑Not Applicable
conditioning unit.
Additional Comments/Assumptions:
11 High Impact (Tier 1) :Z Medium Impact (Tier 2) 3 . Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users�ohnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish.cck Page 28 of 37
Section,
Rough-ln El ectricatinspectlon
=Complies?
Comments/Assumptions: '
C405.2.1 ; Lighting controls installed to uniformly ;❑Complies ;
[EL15]1 !reduce the lighting load by at least
;❑Does Not
50%.
;❑Not Observable;
;❑Not Applicable
C405.2,1 ;Occupancy sensors installed in
;❑Complies
[EL18]1 'required spaces.
;❑Does Not
;❑Not Observable;
j
!❑Not Applicable
C405.2.1, .I Independent lighting controls installed ;❑Complies ;
C405,2.2. per approved lighting plans and all
;❑Does Not
3,- :.manual controls readily accessible and
;❑Not Observable;
[EL23]3 ;visible to occupants.
I
❑Not Applicable ;
C405.2.2. Automatic controls to shut off all
I❑Complies
I )building lighting installed in all
;❑Does Not
[EL22j2 j buildings,
;❑Not Observable:
;❑Not Applicable
C405.2:3 :, Daylight zones provided with
;❑Complies
IEL16]2"individual controls that control the
;❑Does Not
;lights independent of general area
; -]Not Observable;
'li htin
g g
;❑Not Applicable
C405.2.3, ;Primary sidelighted areas are
;❑Complies
C405.2.3. equipped with required lighting
�❑Does Not
1, ;controls.
C405.2.3.
UNot Observable ;
2 ;
;❑Not Applicable
[EL20]1
I
I
1
;
1
I
C405.2.3, !Enclosed spaces with daylight area
;❑Complies ;
C405.2.3. sunder skylights and rooftop monitors
;❑Does Not
1, iare equipped with required lighting
❑Not Observable;
C405.2.3. ,controls.
3 )
,
;❑Not Applicable ;
[EL21]1
I
,
; ;
1
C405.2.4 ,Separate lighting control devices for
;❑Complies ;
[EL4]1 !specific uses installed per approved
:❑Does Not
lighting plans.
I
:❑Not Observable;
;❑Not Applicable
C405.2.4 ;Additional interior lighting power
I❑Complies
[EL8]1 ;allowed for special functions per the
)❑Does Not
approved lighting plans and is
automatically controlled and
❑Not Observable
:separated from general lighting.
❑Not Applicable ;
C405.2.5 (Automatic lighting controls for exteriorl❑Complies
[EL25]"°il "lighting installed. Controls will be
;❑Does Not
daylight controlled, set based on
❑Not ObservableI,
;business operation time -of -day, or
!reduce connected lighting > 30%.
;❑Not Applicable ;
C405.3 ; Exit signs do not exceed 5 watts per
:❑Complies ;
[EL6]1 :face.
{
;❑Does Not
I I
:❑Not Observable;
;❑Not Applicable
Additional Comments/Assumptions:
111 High Impact (Tier 1) 2`1 Medium Impact (Tier 2) ' 3„ Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users�ohnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish.cck Page 29 of 37
111 High Impact (Tier 1) 11. 2 1 Medium Impact (Tier 2) 13-'1 Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070 Cristeile Cay_Sailfish.cck Page 30 of 37
=Section
#
Ir&
Insulation Inspection
Complies?'
'Comments/Assumptions,
Re .ID
C303.1 ;Roof insulation installed per
;❑Complies
[IN3]1 ;manufacturer's
instructions. Blown or
:❑Does Not
;poured
loose -fill insulation is installed
; Observable
;only
I12.
where the roof slope is <=3 in
;❑Not
;❑Not Applicable ;
C303.1 .:',Building envelope insulation is labeled ;❑Complies ;
[1N10]2.,- •'{with
R-value or insulation certificate
:❑Does Not
;data.
providing R-value and other relevant
; ❑;
Not Observable;
❑Not Applicable
C303.2 ;Above
-grade wall insulation installed
;❑Complies
[IN7]1
;per manufacturer's instructions.
;❑Does Not
;❑Not Observable!
j
;❑Not Applicable
;003.2.1
'
1 Exterior insulation is protected from
I❑Complies ;
[IN14,]z..
jVerification
damage with a protective material,
:❑Does Not
)
for exposed foundation
insulation may need to occur during
❑Not Observable
Foundation Inspection.
tlNot Applicable ;
C402:2.7
;Insulation intended to meet the roof
;❑Complies ;
[IN17j3
insulation requirements cannot be
;❑Does Not
{ installed on top of a suspended
ceiling. Mark this requirement
;❑Not Observable
:I
.•;
if insulation is installed
;❑Not Applicable ;
accordingly.
C402.2.3
'Above -grade wall insulation R-value.
;❑Complies ;See the Envelope Assemblies table for values.
[IN6]1
;❑Does Not
❑Not Observable
❑Not Applicable
C402'.2.6•
;Radiant panels and associated
;❑Complies ;
[IN18]3; ` ,;components,
designed for heat
ElDoes Not
transfer from the panel surfaces to the
❑Not Observable
occupants or Indoor space are
I insulated with a minimum of R-3.5.
;❑Not Applicable ;
C402.3 ; High-albedo roofs satisfy one of the
;❑Complies
{IN5]3".
Ifollowing: 3-year-aged solar
:❑Does Not
•,reflectance
>= 0.55 and thermal
[]Not Observable,
remittance >= 0.75 or 3=year-aged
;solar reflectance index >= 64.0.
;❑Not Applicable ;
C402.2.2 r Roof R-value. For some ceiling
;❑Complies ;See the Envelope Assemblies table for values.
[IN2]1
systems, verification may need to
;❑Does Not
occur during Framing Inspection,
❑',
Not Observable;
❑Not Applicable
C402.5.1. ;All sources of air leakage in the
;❑Complies
1
!building thermal envelope are sealed,
T❑Does Not
[IN1]1
!caulked, gasketed, weather stripped
;❑Not Observable;
or wrapped with moisture vapor -
!permeable wrapping material to
:❑Not Applicable
minimize air leakage.
;
Additional Comments/Assumptions:
11 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish.cck Page 31 of 37
SettiOn
#'
Final Inspection
„
. Complie's?
Comments%Assumptions ? ''
&.Re 4D
C303.3,
Furnished O&M instructions for
;❑Complies
C408.2,5.
jsystems and equipment to the
;❑Does Not
2
[FI17]3
; building owner or designated
representative.
;❑Not Observable;
;❑Not Applicable ;
C303.3,
; Furnished O&M manuals for HVAC
;❑Complies
C408.2.5.
;systems within 90 days of system
i❑Does Not
3
[FIB]3
;acceptance.
❑Not Observable
i
;❑Not Applicable ;
C403.2.4. ;Minimum one humidity control device ;❑Complies
2.4
per installed
;❑Does Not
[FI56]3
i humidification/dehumidification
:❑Not Observable;
system. Controls prevent
simultaneous operation of
;❑Not Applicable
humidification and dehumidification
1 equipment.
C403.2.4, !Minimum one humidity control device I❑Complies
2.4
i per installed
;❑Does Not
(FI56]3
;humidification/dehumidification
:[]Not Observable
;system. Controls prevent
'simultaneous operation of
❑Not Applicable ;
humidification and dehumidification
!equipment.
C403:2.4. •; Minimum one humidity control device
;❑Complies ;
2.4
!per installed
;❑Does Not
[F156]3
;humidification/dehumidification
;❑Not Observable;
;system, Controls prevent
(simultaneous operation of
❑Not Applicable
humidification and dehumidification
;
:equipment.
't403.2.4. ;Minimum one humidity control device ;❑Complies ;
2.4
!per installed
:❑Does Not
[F.156,13
;humidification/dehumidification
,system. Controls prevent
❑Not Observable;
simultaneous operation of 'simultaneous
Applicable
humidification and dehumidification
;equipment.
C403.2;4: !Minimum one humidity control device
;❑Complies ;
2.4
per installed
;❑Does Not
[FI56]3
humidification/dehumidification
:[]Not Observable
;system. Controls prevent
!simultaneous operation of
;
°❑Not Applicable
humidification and dehumidification
equipment.
'r
C40 J.4. ;Minimum one humidity control device ;❑Complies
.2.4
I per installed
;❑Does Not
[FI56]3
humidification/dehumidification
❑Not Observable
;system. Controls prevent
simultaneous operation of
;❑Not Applicable
:,humidification and dehumidification
equipment.
,C403.2.4. 1Minimum one humidity control device
;❑Complies
2:4
;per installed
;❑Does Not
[F156]3
°humidification/dehumidification
'system.
❑Not Observable;
Controls prevent
simultaneous operation of
;❑Not Applicable
; humidification and dehumidification
;
; equipment.
1 I High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 1 Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users�ohnferriter\Documents\COMcheck\18070 Cristelle_Cay_Sailfish.cck Page 32 of 37
-Section
#
''Final Inspection ' '
Complies?
Comments/Assumptions .
&'Re .ID'
.
C403.2.4. ;Minimum one humidity control device
;❑Complies
2.4 "• { per Installed
;❑Does Not
[FI56]3 humidification/dehumidification
❑Not Observable
!system. Controls prevent
;simultaneous operation of
;❑Not Applicable ;
humidification and dehumidification
i equipment.
1
C402.5.3 !Where open combustion air ducts
;❑Complies
IF[51]3 provide combustion air to open
;❑Does Not
combustion fuel burning appliances,
the appliances and combustion air
;❑Not Observable:
s opening are located outside the
;❑Not Applicable
building thermal envelope or enclosed
in a room, isolated from inside the
thermal envelope. Such rooms are
;sealed and insulated.
C402.5.6 ; Weatherseals installed on all loading
I❑Complies
[FI37]1 i dock cargo doors.
;❑Does Not
;❑Nat Observable;
{
;❑Not. Applicable
C402.5.8 .'Recessed luminaires in thermal
[]Complies
[F126]3' l envelope to limit infiltration and be IC
rated and labeled. Seal between
;❑Does Not
interior finish and luminaire housing.
}❑Not Observable :
❑Not Applicable ;
C403.2.1 - ; HVAC systems and equipment design
UComplies ;
[F150]3' "loads calculated in accordance with
;❑Does Not
'ANSI/ASHRAE/ACCA Standard 183 or
;
-;ACCA Manual N or by an approved
;❑Not Observable
equivalent computational procedure.
;❑Not Applicable
Design loads shall be attached to the
;
code compliance form submitted to
;
the building department when the
"building is permitted or, in the event
;
the mechanical permit is obtained at a!
"
later time, the sizing calculation shall
.'.',be submitted with the application for
.;the mechanical permit.
C4032.2 ; HVAC systems and equipment
;❑Complies
[F127]3- ;capacity does not exceed calculated
:[]Does Not
loads.
❑Not Observable
❑Not Applicable
-; C403.2.4.Heating and cooling to each zone is
;❑Complies ;
1 "controlled by a thermostat control.
;❑Does Not
'[F14713 ;Minimum one humidity control device
per installed
,❑Not Observable,
Applicable
humidification/dehumidification
;❑Not
system.
C403:2.4. ; Heating and cooling to each zone is
;❑Complies
1 ' controlled by a thermostat control.
[FI4:7]3 Minimum one humidity control device
;❑Does Not
per installed
humidification/dehumidification
❑Not Observable;
![]Not Applicable
system.
C4012.4.." Heating and cooling to each zone is
;❑Complies ;
?1 t controlled by a thermostat control,
;❑Does Not
[FI47]3 ;Minimum one humidity control device
per installed
; Not Observable ;
❑
humidification/dehumidification
;❑Not Applicable
`':"system.
11 High Impact (Tier 1) .'2'. I Medium Impact (Tier 2) 3s Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename; C:\Users\johnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish.cck Page 33 of 37
Section.
#:
Flnahlnspe¢tion
.Complies?
Comments/Asswmptions
& Re .ID
C403.2.4. !Heating and cooling to each zone is
;❑Complies
1
!controlled by a thermostat control.
;❑Does Not
[FI47]3
Minimum one humidity control device
;❑Not Observable;
;per installed
(humidification/dehumidification
;❑Not Applicable
system.
C403.2.4.
!Heating and cooling to each zone is
;❑Complies
1
'controlled by a thermostat control,
;❑Does Not
[FI47]3
; Minimum one humidity control device
;❑Not Observable'
I per installed
humidification/dehumidification
;❑Not Applicable
:system.
C403.2.4. IHeating and cooling to each zone is
;❑Complies
1
controlled by a thermostat control.
;❑Does Not
[FI47]3
:Minimum one humidity control device
;❑Not Observable
:per installed
ihumidification/dehumidification
�DNotApplicable
system.
C403.2.4.
:Heating and cooling to each zone is
;❑Complies
1
!controlled by a thermostat control.
;❑Does Not
[FI47]3
;Minimum one humidity control device
;❑Not Observable;
per installed
humidification/dehumidification
;❑Not Applicable
system.
C403.2.4.
I Heating and cooling to each zone is
;❑Complies
I
:controlled by a thermostat control.
;❑Does Not
[F[47.]3
Minimum one humidity control device
;❑Not Observable;
per installed
? humidification/dehumidification
;
;❑Not Applicable ;
system.
; ;
C403.7.4, ; Heat pump controls prevent
;❑Complies
1A
;supplemental electric resistance heat
:❑Does Not
[FI42]3,..
;from coming on when not needed.
'
;❑Not Observable:
❑Not Applicable :
C403.2:4. 1 Heat pump controls prevent
i❑Complies
1.1 1..
supplemental electric resistance heat
!❑Does Not
[Fl42]3
,from coming on when not needed.
;❑Not Observable:
:,[]Not Applicable
C463.7.4: -I Heat pump controls prevent
;❑Complies ;
IA_---_` ,;supplemental
electric resistance heat
❑Does Not
[FI42]3,: _
;from coming on when not needed.
;❑Not Observable ;
❑Not Applicable
C403.2:4. Thermostatic controls have a 5 °F
;❑Complies
1.2 -
� deadband.
;❑Does Not
[F138]3'.
;
❑Not Observable;
❑Not Applicable
C403.2.4. (Temperature controls have setpoint
;❑Complies
1.3
;overlap restrictions.
{❑Does Not
[FI20]3
;
;❑Not Observable:
❑Not Applicable- j
C403.2:4.: ; Each zone equipped with setback
;❑Complies
2,-
(controls using automatic time clock or
I❑Does Not
[FI39j3
; programmable control system.
❑Not Observable;
j❑Not Applicable
1 I High Impact (Tier 1) :2,` Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\ ohnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish.cck Page 34 of 37
section
;
#-
Final. Inspection ".
Complies? ' . Comments/Assumptions
&:Re .ID
C408.2.2 I Construction documents require that a
;❑Complies
[FI54]3 jwritten balance report be provided to
;❑Does Not
;the building owner or rep for HVAC
:systems serving zones with total
;
:❑Not Observable
:condition area > 5,000 sgft. Air
:❑Not Applicable ;
;distribution systems shall be tested,
j
ladjusted, and balanced by a licensed
;
i engineer or certified company.
C403.2:4.. ;Automatic Controls: Setback to 55°F
;❑Complies
2.1; , � • • ,1(heat) and 85°F (cool); 7-day clock, 2-
:❑Does Not
C403.2.4.-;hour occupant override, 10-hour
❑Not Observable:
2.2; ' ' backup
[FI40]3;.- .I
;❑Not Applicable
C403.2.4.•;Systems include optimum start
;❑Complies
2.3: controls.
;❑Does Not
,❑Not Observable;
❑Not Applicable
C403.2.4.•.ISystems include optimum start
;❑Complies
2:3: 4controls.
;❑Does Not
[FI41]3'
UNot Observable ;
❑Not Applicable
C403.2'4. ;Systems include optimum start
;❑Complies ;
2.3. : -.: , controls.
;❑Does Not
[FI4l13 '• ;
;❑Not Observable:
I
:❑Not Applicable
C403.2.4.•,!Systems include optimum start
:❑Complies ;
2.3 , ;controls.
;❑Does Not
[FI41]3.,,
:❑Not Observable ;
:j
;❑Not Applicable
C403.24. ,Systems include optimum start
:❑Complies
2.3, controls.
:❑Does Not
[F141]3,
:
:❑Not Observable:
❑Not Applicable
C405.4.1 'Interior installed lamp and fixture
;❑Complies ;See the Interior Lighting fixture schedule for values.
[FI18]1 !lighting power is consistent with what
:Does Not
is shown on the approved lighting
j
; plans, demonstrating proposed watts
;❑Not Observable
:❑Not Applicable
,:are less than or equal to allowed
watts.
C405,5.1 ; Exterior lighting power is consistent
:❑Complies ;See the Exterior Lighting fixture schedule for values.
[FI19]1 ;with what is shown on the approved
:❑Does Not
(lighting plans, demonstrating
proposed watts are less than or equal
;❑Not Observable
Ito allowed watts.
:❑Not Applicable
C408.2.1 ;Commissioning plan developed by
bComplies
[F[28]1 : registered design professional or
;❑Does Not
;approved agency.
,
;❑Not Observable;
❑Not Applicable
C408.2.3. ; HVAC equipment has been tested to
I❑Complies ;
1 !ensure proper operation.
;❑Does Not
[FI31]1
;❑Not Observable
❑Not Applicable
11 High Impact (Tier 1) 2Medium Impact (Tier 2) 3 . Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users�ohnferriter\Documents\COMcheck\18070 Cristelle Cay_Sailfish.cck Page 35 of 37
Section
#;
Final Inspection
Complies?
: Comments/Assumptions s'
C408.2.3.
;HVAC control systems have been
;❑Complies
2
;tested to ensure proper operation,
;❑Does Not
[FI10]1
;calibration and adjustment of controls.
;❑Not Observable
❑Not Applicable
C408.2.4 ;Preliminary commissioning report
;❑Complies ;
[FI29]1
;completed and certified by registered
;❑Does Not
;design professional or approved
❑Not Observable ;
1 agency.
❑Not Applicable
C408.2.5.
' Furnished HVAC as -built drawings
:,❑Complies ;
;1
!submitted within 90 days of system
:❑Does Not
[F17]3
jacceptance.
❑Not Observable ;
❑Not Applicable ;
C408.2.5. ; Furnished as -built drawings for
;❑Complies
1
:electric power systems within 90 days
1❑Does Not
(FI16]3
'of system acceptance,
;❑Not Observable;
❑Not Applicable
C408.2.5. ;An air and/or hydronic system
1❑Complies
3
:balancing report is provided for HVAC
1❑Does Not
[FI43]1
;systems.
;❑Not Observable 1
❑Not Applicable
C408.2.5. ;Final commissioning report due to
;❑Complies ;
4
"building owner within 90 days of
!❑Does Not
[F130]1
;receipt of certificate of occupancy.
;[]Not Observable;
❑Not Applicable
C408.3
;Lighting systems have been tested to
;❑Complies
[FI33]1
;ensure proper calibration, adjustment,
;❑Does Not
programming, and operation.
;❑Not Observable
1
;❑Not Applicable
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2"' Medium Impact (Tier 2) 1_3'-J Low Impact (Tier 3)
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\johnferriter\Documents\COMcheck\18070 Cristelle Cay_5ailfish.cck Page 36 of 37
Project Title: 18070 Cristelle Cay Sailfish Report date: 12/10/18
Data filename: C:\Users\ ohnferriter\Documents\COMcheck\18070 Cristelle Cay_Saiifish.cck Page 37 of 37