Loading...
HomeMy WebLinkAbout216860-1d Compaction signedHeadquarters 1W 40 IL � ENGINEERING Mailing 11345 U.S. Highway 1 PO Box 78-1377 Sebastian, FL. 32958 1 %% AND TESTING Sebastian, FL. 32978 Orlando Phone: 772-589-0712 723 Progress Way SOIL COMPACTION REPORT C.A.# 5693 Sanford, FL. 32771 ASTM D 1557 and ASTM D 6938 KSMengineering.net DATE TESTED: August 27, 2021 KSM JOB #: 216860-1d/BS/jam NUC # 528 PERMIT #: 2102-0352 Nuc Model: MC-IDR-P Nuc Serial #: MD049528 CONTRACTOR: Adams Homes JOB LOCATION: 8205 Amalfi Circle Lot 16, Block 2, Waterstone Fort Pierce, Florida ITEM TESTED: Compacted Foundation Fill TEST LOCATION PEN DRY MAX. DRY PERCENT DEPTH OF SAMPLE READ DENSITY PROCTOR VALUE (P.C.F) COMPACTION 1 S.E. 0" - 12" 45 108.1 111.3 97.1% 2 S.W. 1140 107.3 1196.4% 3 Center 1140 107.6 1196.7% 4 N.W. 1145 108.4 1197.4% 5 N.E. 1145 108.2 1197.2% Soil Description: 113.0 I I I I I I I Brown Sand with Traces of Rock W E 112.0 J—.. �..—.i—.. � ..—i.—..� �..—.�—.._ In Place Moisture: I I I I I I I I I 11.1% H 111.0 Proctor Optimum Moisture: T 110.0 I— J..—.I_..1. _1._..L..J. _.I_.._ 11.0% p I I I I I I Proctor Max. Dry Density: P.C.F. 109.0 — • 1 — I — l -4• • — • — 111.3 C I I I I I I @ Test Locations the Density & F 108.0 I— Penetrometer readings indicate the I I I I I I Degree of Compaction Meets 107.0 Minimum Requirement D 1 —1 I—' T'—I'—"r"-1'•—'1—' for Unstaked Foundation R I I I I I I I 106.0..�..—.i_..t.._�.—..r..�.._.�—..� Respectfully Sul itted- Y 6 7 8 9 10 11 12 13 14 g y Moisture - % of Dry Weight signed by This item has been electronically signed and Julie Keller Disclaimer: Contractor is responsible to maintain the tested area sealed bJ the date y stated directly [o [he right usingulie Keller, P.E. FI. Lic. 68366 on a digital s,gn,tnr,, Date: in the condition that KSM completed the indicated passed Printed copies of this document are not cnnsideredsignedabdsbaled aedthe j(( compaction test. KSM is not responsible if the tested area has signature must be verified on any electronic 2 021 .0 V . 0 cn,ies been altered from the approved inspected condition. 14:56:02 -04'00' Julie E. Keller, P.E. President PE # 68366 8/30/2021 Email to: rick.johnson@adamshomes.com Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Proudly Serving Florida since 1990 Certified Women Owned Business - WBE